Pawnee_Campground_Water_System_As-Builts.pdf

PDF 2 MB Posted

Attached to
CO FLAP 102(1) and FTFW 112(2) Brainard Lake Road and Bridge
Solicitation number
DTFH6817B00019
Issued by

About this file

Pawnee Campground Water System As-Builts

View the file

Other files

File Type Posted
Bid_Opening_Summary_10.11.17.pdf PDF
2017-10-02_Q&A.pdf PDF
Amendment_A004.pdf PDF
Amendment_A003.pdf PDF
2017-09-29_Q&A.pdf PDF
A003_E_Section.pdf PDF
Option_Y_Waterline_Plans_Updated_92917.pdf PDF
2017-09-28_Q&A.pdf PDF
Amendment_A002.pdf PDF
2017-09-22_Q&A.pdf PDF
3D_ALICO102(1).dgn —
XSECO102(1)_Final.dgn —
CO_102(1)_ExistingGround.xml XML file
2017-09-20_Q&A.pdf PDF
2017-09-18_Q&A.pdf PDF
A001_E24.pdf PDF
SF_30_Amendment_Form.pdf PDF
Brainard_Lake_Bridge_Replacment_03_1987.pdf PDF
DTFH6817B00019_IFB.pdf PDF
CO_FLAP_102(1)_Brainard_Lake_Road_Pavements_Report_2-25-2015.pdf PDF
Century_Link_Records_for_Brainard_Road.pdf PDF
Brainard_Lake_Bridge_Replacment_03_1987_3.pdf PDF
CO_102(1)_PDF.pdf PDF
CO_102(1)_PDF_XS.pdf PDF
Brainard_Lake_Bridge_Replacment_03_1987_4.pdf PDF
Show all 25

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

U.S. DEPARTMENT OF AGRICULTURE

FOREST SERVICE

ROCKY MOUNTAIN REGION

jmoore Text Box As-Built Drawings / November 2, 2011 Hydro Construction Co. Inc.

Fort Collins, CO 970-225-2211 Contact: Kenny Samsel, John Moore jmoore Pencil jmoore Callout Waterline re-routed to follow previous route jmoore Rectangle jmoore Line jmoore Callout New 2000 Gal Septic Holding Tank with inlet and risers for host sites jmoore Line jmoore Callout 4" Gate Valve jmoore Line jmoore Polygon jmoore Line jmoore Callout 4" Supply jmoore Line jmoore Line jmoore Line jmoore Callout Waterline installed in road right shoulder

Pencil jmoore Polygon jmoore Line jmoore Polygon

Line

NOT TO SCALE

WELL DETAIL

U4

B

NOT TO SCALE

WELL CONNECTION - ISOMETRIC

U4

A

NOT TO SCALE

WELL PUMP DRAIN DETAIL

U4

C

Checked:

Design:

FOREST SERVICE

U.S. DEPARTMENT OF AGRICULTURE

ROCKY MOUNTAIN REGION

Forest

Date:

Drawn:

Sheet Title: Sub Sheet:

Sheet

Project No:

WELL DETAILS

PAWNEE CAMPGROUND WATER SYSTEM

ARAPAHO/ROOSEVELT

NATIONAL FOREST

BOULDER RANGER DISTRICT 6 14

jmoore Line jmoore Line jmoore Callout HDPE Well Feed Line is sloped back to the well with a bleeder hole in well to allow line to self drain back into well jmoore Line jmoore Line jmoore Line jmoore Line jmoore Line jmoore Line jmoore Line jmoore Line jmoore Line

ROCKY MOUNTAIN REGION

R-2

STORAGE TANK

DETAILS

PAWNEE CAMPGROUND WATER SYSTEM

ARAPAHO/ROOSEVELT

NATIONAL FORESTS

BOULDER RANGER DISTRICT 7 14

jmoore Callout 6'-0" jmoore Callout 3'-6" jmoore

4"

ROCKY MOUNTAIN REGION

R-2

STORAGE TANK INSTALLATION

DETAILS AND ISOMETRIC

PAWNEE CAMPGROUND WATER SYSTEM

ARAPAHO/ROOSEVELT

NATIONAL FOREST

BOULDER RANGER DISTRICT 8 14

jmoore Line jmoore Line jmoore Callout 4" Gate Valve jmoore Line jmoore Line jmoore Line jmoore Line jmoore Line jmoore Callout

4" HDPE

jmoore Callout Drain removed at Pre-Work Mtg jmoore Line jmoore Line jmoore Line jmoore Line jmoore Line jmoore

4" dia

ROCKY MOUNTAIN REGION

TREATMENT BUILDING

ELEVATIONS

PAWNEE CAMPGROUND WATER SYSTEM

ARAPAHO/ROOSEVELT

NATIONAL FOREST

BOULDER RANGER DISTRICT 9 14

Tapped with Schrader Valve to allow drain back jmoore Line jmoore Line jmoore Line jmoore Line jmoore Line

ROCKY MOUNTAIN REGION

R-2

UTILITY DETAILS

PAWNEE CAMPGROUND WATER SYSTEM

ARAPAHO/ROOSEVELT

BOULDER RANGER DISTRICT 11 14

NOT TO SCALE

HYDRANT PAD DETAIL

U10 C

NOT TO SCALE

HOST HYDRANT DETAIL

U10 A

Checked:

Design:

FOREST SERVICE

U.S. DEPARTMENT OF AGRICULTURE

ROCKY MOUNTAIN REGION

Forest

Date:

Drawn:

Sheet Title: Sub Sheet:

Sheet

Project No:

HYDRANT

DETAILS

PAWNEE CAMPGROUND WATER SYSTEM

ARAPAHO/ROOSEVELT

NATIONAL FOREST

BOULDER RANGER DISTRICT 12 14

NOT TO SCALE

HYDRANT DETAIL

U10 B

ROCKY MOUNTAIN REGION

R-2

TREATMENT BUILDING

WIRING SCHEMATIC

PAWNEE CAMPGROUND WATER SYSTEM

ARAPAHO/ROOSEVELT

BOULDER RANGER DISTRICT 13 14

OUTLET DITCH CROSS SECTION

TYPICAL INSTALLATION WITH OUTLET DITCH

TYPICAL INSTALLATION IN SIDEHILL SECTION

TYPICAL INSTALLATION IN FILL SECTION

TYPICAL BACKFILL DETAIL

DITCH BLOCK

PROFILE ALONG DITCH

PLAN

NOT TO SCALE

TYPICAL BACKFILL DETAIL

C1

A

NOT TO SCALE

TYPICAL DITCH BLOCK DETAIL

C1

B

NOT TO SCALE

TYPICAL CULVERT INSTALLATIONS

C1

C

FOREST SERVICE

U.S. DEPARTMENT OF AGRICULTURE

ROCKY MOUNTAIN REGION

R-2

CULVERT DETAILSARAPAHO/ROOSEVELT

BOULDER RANGER DISTRICT 14 14

File details come from the government source that posted it. Updated .