ditions beyond these specifications, consult the local Johnson Controls office.
P2000 Security Management System Professional Edition Version 3.13
Code No. LIT-1900914
Issued July 30, 2014
Cardholder Management
Web Alarm Management and ID Viewer Mobile Application
Alarm Monitoring
Real-Time Monitoring The performance specifications are nominal and conform to acceptable industry standards. For applications at con
Description The Johnson Controls® P2000 Security Management System (SMS) represents the latest technology in integrated security solutions. Using Microsoft® Windows® operating systems, operators can easily configure and use the P2000 software. An underlying Microsoft SQL Server® database engine offers high performance without high overhead.
The Professional Edition of the P2000 SMS is designed for medium-sized installations such as office buildings with multiple tenants, small offices with increased security requirements, and primary schools. It includes all of the standard P2000 features in addition to the following items:
• Up to 128 readers
• Up to 5 client user connections
• Up to 25,000 cardholders
Standard Features and Benefits
• Application Programming Interface (API) — allows applications to execute methods in the P2000 system to lock and unlock doors, set and reset output points, acknowledge alarms, trigger P2000 host events, and more.
• Area Control — controls the number of cardholders allowed within a specific area. Operators can monitor the area at any time to determine the current number of cardholders in a particular area, and the entry and exit of personnel or vehicles into a controlled area (for example, a room or parking structure). The system can report and display in real time the number and names of cardholders within the area at any given time.
• Closed Circuit Television (CCTV) Integration — interfaces with approved CCTV systems to provide visual security in areas that may require real-time surveillance monitoring. The P2000 software provides on-screen controls to operate the switches, cameras, and monitors that are part of the CCTV system.
Other components that are part of the CCTV system include switch alarms, macros, auxiliaries, and tours; monitor sequences; and camera patterns, presets, and auxiliaries. You can configure your CCTV system to operate continuously or run by event actions to monitor particular events.
• Database Partitioning — restricts user access to a certain subset of records within the database, so that a user of one partition, for example, cannot add, modify, or view cardholder records of another partition. Operators can assign users to single or multiple partitions.
• Data Import and Export for CK721-A and S321-IP Controllers — allows you to import and export CK721-A and S321-IP hardware configuration data, which reduces the commissioning time required to enter this information during configuration. Site administrators can preconfigure controllers, terminals, time schedules, access groups, and other configuration settings using a standard Microsoft Excel® spreadsheet provided by a Johnson Controls representative. After you save the .xls file as a comma separated values (.csv) file, the settings can be imported into a P2000 database.
• Distributed Deployment — enables you to separate the P2000 services from the P2000 database, useful for installations where the database needs to be housed on a separate computer, such as on a database server.
• Encryption — secures every message to and from the controller using Advanced Encryption Standard (AES) to protect the P2000 system from unauthorized sources. P2000 Version 3.13 Encryption is implemented using Federal Information Processing Standards (FIPS) 140-2, validated, (Certificate #1336), cryptographic module, from Microsoft http://www.microsoft.com
• Enhanced MIS Interface — enables the P2000 system to receive cardholder information and data requests from an external database source such as a Human Resource database. Using the MIS Interface in conjunction with an external Open Database Connectivity (ODBC)-based program, the MIS Interface can add, modify, and delete cardholders and their badges in the P2000 system according to data input from an external system. Both the external system and the P2000 system can exchange a wide range of data between the Input and Output tables, including access groups, time zones, partition data, and even pictures. Operators can query cardholder information using wildcards.
• Event Triggers and Actions — automatically initiate a sequence of system commands (actions) based on system events and messages (triggers). Triggers determine which conditions must be met to initiate a specific action.
Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. © 2014 Johnson Controls, Inc. www.johnsoncontrols.com http://www.microsoft.com http://www.microsoft.com http://www.microsoft.com
P2000 Security Management System Professional Edition Version 3.13 (Continued)
• Guard Tour — provides real-time monitoring of guard activities to verify and record that a guard has physically visited a facility within a specified time – reporting an early or late arrival to a designated guard tour station. The P2000 system uses readers and input points to define each guard tour station. The system allows alarm configuration to report guard tour conditions and provides a control application to start and stop tours, and monitor their progress.
• Hours on Site Reporting — records cardholders’ accumulated hours present at a site. This feature is used exclusively for tracking and reporting purposes, and works by recording the cardholder's time interval between an in badging and out badging at reader terminals defined to monitor Hours on Site.
• Low-Level Elevator Access and Cabinet Control — communicates with a variety of elevator and cabinet equipment to provide basic cardholder access.
• Mercury Access Control Products and LifeSafety Power® Panel Assemblies — are now integrated with the P2000 SMS, providing added flexibility to help customers meet the needs of their site's security requirements and applications using a well known and time-tested security products manufacturer while making it easy to power, house, and store the Mercury components in a secure enclosure and in a variety of configurations. The EP Series controllers also allow customers to use the same hardware they use for access control for intrusion detection. In addition, the P2000 Mercury integration allows the use of existing Authentic Mercury EP Series access control hardware without firmware updates. Customers can migrate to P2000, leveraging their Authentic Mercury EP Series hardware from other manufacturers. A complementary license is required.
For more information regarding the Mercury integration, refer to the Mercury Products Open Platform Solution Product Bulletin
(LIT-12011850).
• Message Filtering and Routing — allows operators to transmit and receive specific messages to and from specific local or remote P2000 systems, thereby reducing network traffic by transmitting and receiving only messages that pass a filter criteria.
The Remote Message Server (RMS) maintains central control over all message routing and transmits messages only to P2000 servers or workstations that the RMS assumes are able and willing to receive messages.
• Metasys® System Integration — provides complete support of the integration between a single Metasys system and the P2000 system. The Metasys building management system uses web-based technology to monitor and supervise facility controls such as HVAC, lighting, and fire control system supplementary monitoring. This high-level integration enables Metasys operators to access certain key security management features of the P2000 system from the Metasys web-based user interface. This interface allows the P2000 Host and Panel objects to be visible to the Metasys user. The user can browse P2000 items, view alarms and messages, send access control commands, and create interlock events.
• Multiple Client Options — give customers the flexibility to manage their systems how they see fit. The Professional Edition allows 5 concurrent client connections to the P2000 server in any combination of the computer-based thick client, the web-based thin client, or the mobile applications. The computer-based thick client provides operators access to interactive real-time facility maps featuring dynamic icons, to monitor and control major facility systems and functions. Authorized operators can create cardholder records, define hardware components, and control access using badging, Closed Circuit Television (CCTV), Digital Video Recorders (DVRs) and Video Management Systems (VMSs), area control, mustering, and elevator control to name a few, as well as monitor local and remote transactions and alarm activity in real time. The web-based thin client allows users to The performance specifications are nominal and conform to acceptable industry standards. For Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse o
2 of access P2000 alarm management and reporting from any workstation. Each of the mobile applications, Alarms, Door Control, and ID Viewer, allow mobile personnel to perform specific functions from a mobile phone or tablet on a Wi-Fi connection.
Alarms allows a user to view and respond to alarms, Door Control allows a user to lock or unlock a door, and ID Viewer allows a user to review recent door activity.
Note: Web and mobile clients require the P2K-SW-AEM313 option.
• Mustering — allows operators to track personnel movement in the event of an emergency. When an emergency occurs, all personnel within a risk area are expected to evacuate and must present their badge at a reader away from the risk area. Real-time printed reports and online display information enable the operator to track movement of personnel out of the risk area. Operators can use the same information to direct search and rescue operations.
• Online Tutorial — presents an overview of the P2000 system's major features and options, covering a number of system configuration, installation, and troubleshooting tips. The modular design enables navigation to tutorial topics and sub-topics through Adobe® Flash® presentations that provide audio narration (with matching text if desired) to guide users on how to make the most of P2000's most popular features.
• Real-Time Monitoring — provides dynamic displays of system transactions and operations using the Real Time List, which is a time-stamped display of local or remote transactions as they occur; and the Real Time Map, which displays the current status of local terminals, doors, intrusion components, intercom stations, inputs, outputs, and other defined elements on a map layout of the facility.
• Remote Messaging with External Systems (P2000 Remote Messaging Service [RMS]-XML Interface) – allows a remote server or external application to receive real-time messages from other P2000 systems or third-party components. This interface enables applications to receive access grant and access deny messages, hardware status change messages, alarm messages, and audit messages. A message filter can optionally be configured to limit the type of messages transmitted. The RMS-XML interface is an extension of the existing RMS Interface designed to send P2000 real-time messages to other P2000 systems.
• Security Threat Level — provides a rapid method of restricting access in case of an emergency. In the event of a security breach, an authorized operator can quickly change access privileges for any or all cardholders at any or all terminal readers defined for security level control. Security threat level is not supported on all controllers.
• Simplified System Configuration and Monitoring — provides a user-friendly interface for easy operation. Operators can accomplish critical system functions from the:
- System Configuration window to enable operators to configure and manage controllers, readers, input points, and output points.
- Cardholder window to facilitate setup and maintenance of badge-holders and related access parameters particular to the individual.
- Alarm Monitor window to provide immediate access to the current alarm queue with maps of the alarm site.
• Support of Multiple Microsoft Windows and SQL Server Platforms — allows P2000 to leverage existing equipment and run on new systems alike. This allows a significant potential cost savings.
• System Reports — provide operators access to system data, such as the cardholder database, or specific system transactions or configurations. Operators can review the reports on-screen or applications at conditions beyond these specifications, consult the local Johnson Controls office.
f its products. © 2014 Johnson Controls, Inc. www.johnsoncontrols.com
P2000 Security Management System Professional Edition Version 3.13 (Continued) print them. The P2000 system integrates with SAP® Crystal Reports® software to create custom reports. An Archive and Report Server software option is also available for sites requiring the storage of data and generation of reports on a separate server. This ensures rapid creation of reports and also frees the P2000 server from having its system resources used to create reports, increasing speed and stability for both systems.
• System Status Display — graphically displays status information of panels and associated devices configured in the system. This troubleshooting tool allows operators to quickly determine if panels and connected devices are communicating. If communications go down between the server and the devices, the system displays the known status of the devices.
• User Software Privileges — enable administrators to use a combination of user accounts, menu permissions, and password controls to provide very tight restrictions on the viewing and editing of cardholder data and on the operational functions available to a particular user within the system. P2000 optionally integrates to a customer's Active Directory for user authentication.
• Web Access — enables users to perform various P2000 tasks from any web-ready computer or tablet. Users can send requests to add, edit, or delete cardholder records; add a visitor to the P2000 system; track cardholder activity; immediately disable a cardholder record in case of an emergency; print and encode cardholder badges from a Web Access computer; and more.
Web Access provides the flexibility and convenience of using a standard web browser to keep a facility’s cardholder data current and perform other important security functions such as monitor, acknowledge, and remove alarms; activate or deactivate output points (for example, turn on/off lights); and lock or unlock doors.
Web Access uses a single user client connection.
Optional Features and Benefits
• Digital Video Recorder (DVR)/Video Management System
(VMS) Integration— integrates with approved DVR/VMS systems, allowing authorized operators to manage recording and Pan, Tilt, and Zoom (PTZ) functions of many cameras from a single P2000 workstation. Depending on the DVR/VMS equipment used, operators can search, retrieve, and download real-time or archived Audio/Video (AV) recordings from any transaction or surveillance camera. Additionally, operators can tie P2000 event triggers and actions to live AV recordings.The Professional Edition supports a single integration type from following DVR/VMS products:
- Aimetis Symphony®
- Avigilon® Control Center
- Bosch® Video Management System
- Genetec® Omnicast®
- Honeywell® Rapid Eye®
- Milestone Xprotect® Corporate, Enterprise, Professional and Express
- Nice®
- OnSSI® Ocularis® CS
- Panasonic® WJ-ND300 and WJ-ND400
- Pelco® DX8100 and Endura®
- Verint® Nextiva®
• Enterprise Configuration — allows a group of systems, consisting of more than one P2000 server, to exchange cardholder information to create global cardholders, with access permissions over multiple sites. A system administrator enters the information only at the central server and the system subsequently synchronizes the information with the other regional sites within the Enterprise system. This feature also enables operators to view remote alarm messaging information across the Enterprise system.
The performance specifications are nominal and conform to acceptable industry standards. For Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse o
3 of
• Fire Alarm Integration — allows a P2000 user to monitor alarms from a Honeywell Notifier (EU only) fire alarm system.
• High Availability — allows P2000 to run on multiple computers without having to re-register. This enables high availability and fault tolerant solutions such as Stratus® everRun® software to provide a fail-over installation of the P2000 system in case of system failure.
• High-Level Elevator Access Control Integration — communicates with a variety of elevator equipment to provide cardholders with access to various elevators and floors in a facility. The P2000 system supports high-level interfaces to KONE™ IP, Otis® Compass® destination and EMS, and ThyssenKrupp® elevator systems.
• Intercom Integration — interfaces with Zenitel and Commend™ intercom systems to establish audio communication links between any two or more defined intercom stations. This interface provides P2000 applications to control and display all intercom call requests coming from defined intercom stations. The operator can select a call request from the list and connect to any single intercom station, or to a group of stations. The P2000 server retrieves messages coming from the intercom equipment and uses them for event activation and distribution to P2000 workstations for the processing of intercom history messages and alarms.
• Intrusion Detection Integration — enables operators to sense intrusion in a protected building and report it to responsible parties. This feature is accomplished with a combination of detection, control, and reporting devices such as a control panel, input devices (sensors), and output devices (bells, sirens). P2000 operators can send intrusion commands to the intrusion panel (OPC Aritech or Bosch®) to arm and disarm areas, test inputs in a selected area, start or stop bypass on selected zones, and silence an annunciator from P2000 servers or workstations.
• SIA Interface to Bosch (formerly Radionics) D6600 Communications Receiver/Gateway — allows receiving alarm and supervisory messages from digital dialers over analog telephone lines and communicates them to the P2000 server through an RS-232 connection.
• Third-Party Readers/Controllers — from several manufacturers are supported through P2000 expansion options allows additional customization, such as combination reader/controller or wireless devices to the P2000.
• Video Badging — provides visual identification of cardholders using custom badge layouts, which operators can create quickly and easily through the graphical user interface. An operator can add multiple elements to a badge, including company logos, cardholders portraits, custom text, bar codes, and signatures.
Software Support Agreements Johnson Controls also offers a Software Support Agreement (SSA) for the P2000 Security Management System. As part of the agreement, customers receive all available updates of our P2000 Security Management Software and access to factory technical support. For more information, refer to the P2000 Software Support Agreement (SSA) Catalog Page (LIT-1900819).
applications at conditions beyond these specifications, consult the local Johnson Controls office.
f its products. © 2014 Johnson Controls, Inc. www.johnsoncontrols.com ional Edition Version 3.13 (Continued) P2000 Security Management System Profess
Ordering Information (Part 1 of 2) Product Code Number
Description
P2K-SW-PRO313 Fully expandable base P2000 system that supports 5 concurrent user connections using thin or thick clients. Includes all of the standard P2000 features. In addition, provides support for the following: Metasys Integration, Elevator Control, Cabinet Control, Guard Tour, High Availability, Remote Server Connections, Message Filtering, Serial Panels, Intercom, and P2000 Workstations. Also supports 25,000 cardholders.
P2K-SW-ARS313 P2000 Archive Report Server software option, enabling operators to store data on a separate server and generate detailed reports using the server’s data.
P2K-SW-AEM313 Enables the new P2000 web alarm and event management as well as P2000 mobile applications
P2K-SW-ENT313 P2000 Enterprise Access Management option.
This option enables two or more existing P2000 installations to form an enterprise system.
One P2K-SW-ENT312 required for each participating P2000.
P2K-SW-VI313 P2000 Video Badging license. Package includes license certificate. No additional hardware or software is supplied with this option (the P2000 Installation DVD contains the video badging workstation software). One license required per P2000 video imaging station.
P2K-SW-HA313 P2000 High Availability option – Allows P2000 to run on multiple computers without having to re-register.
P2K-DV-AMTS313 Aimetis integration
P2K-DV-AVGN313 Avigilon integration
P2K-DV-BVMS313 Bosch VMS integration
P2K-DV-GNTEC313 Genetec integration option
P2K-DV-RPEYE313 Honeywell Rapid Eye integration option
P2K-DV-MILE313 Milestone integration option The performance specifications are nominal and conform to acceptable industry standards. For Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse o
4 of
P2000 Professional Edition Technical Specifications P2000 Req
Server Operating Systems1
1. For supported operating system and database engine combinations, refer to t
Windows Server® 2008 Service Pa Service Pack 1 Standard without H
Workstation Operating Systems 32-bit and 64-bit: Windows 7 (Pro Windows 8.1 (Professional and En
Database Engine1 SQL Server® 2008 R2 Standard 32 Standard 32-bit and 64-bit
Number of Seats Supported 5
Number of Readers Supported 128
Number of Badging Stations Supported Up to 5
Number of Cardholders Supported 25,000
Panel Types Supported CK721-A Version 3.0, 3.1, or 3.2 w CKM-EPXXXX and Authentic Merc Schlage® PIM400-1501 Versions 1 S321-IP Versions 2.5 to 2.10.3 or g Stanley OSI & Wi-Q (Version 3.00.
Isonas (Freescale 9.20 and PIC 3.
HID Edge Version 2.2.7.300 HID Edge EVO Version 2.3.1.927 Assa Abloy (N05+) P2K-DV-NXTVA313 Verint Nextiva integration option
P2K-DV-NICE313 Nice integration option
P2K-DV-ONSSI313 OnSSI Ocularis CS integration option
P2K-DV-PAN313 Panasonic integration option
P2K-DV-XPRT313 Pelco integration option
P2K-P-ASSA313 Assa Abloy® IP controller interface (8 readers)
P2K-P-EDGE313 HID® Edge® and Edge EVO reader/controller interface (8 readers)
P2K-P-STN313 Stanley® OSI OMNILOCK® and Wi-Q™ wireless reader interface (8 readers)
P2K-P-POE313 PowerNet by Isonas reader/controller interface (8 readers)
P2K-IA-BOSCH313 Bosch Intrusion interface (1 panel)
P2K-IA-GE313 Aritech intrusion interface (Europe only)
P2K-FA-NOTE313 Notifier interface (1 connection - Europe only)
P2K-CS-SIA313 SIA interface to Bosch D6600 (1 connection)
P2K-INT-CMD313 Commend Intercom interface (1 connection)
P2K-INT-ZEN313 Zenitel intercom interface (1 connection)
P2K-ELV-CMPS313 Otis Compass Destination Elevator System interface
P2K-ELV-OTIS313 Otis EMS Elevator System interface
P2K-ELV-KONE313 KONE High Level Elevator IP integration
P2K-ELV-TK313 ThyssenKrupp Elevator System interface
P2K-P-MERC313 P2000 Mercury panel interface option
Ordering Information (Part 2 of 2) Product Code Number (Continued)
Description applications at conditions beyond these specifications, consult the local Johnson Controls office.
f its products. © 2014 Johnson Controls, Inc. www.johnsoncontrols.com uirements he P2000 Software Installation Manual (24-10786-141).
ck 2 Standard 32-bit and 64-bit without Hyper-V, Windows Server 2008 R2 yper-V, Windows Server 2012 Standard fessional, Ultimate, and Enterprise), Windows 8 (Professional and Enterprise), terprise)
-bit, SQL Server 2008 R2 Enterprise 64-bit, SQL Server 2012 ith RDR2S-A/I8O4 Version PS-217F and RDR8S/I32O16 Version PS-218B ury EPXXXX Versions 1.17.3 and 1.18.7 .17.3 and 1.18.7 reater
38, Portal Firmware Version 3.0.17.155, and Reader Version 3.00.039) 08)
The performance specifications are nominal and conform to acceptable industry standards. For applications at conditions beyond these specifications, consult the local Johnson Controls office.
Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. © 2014 Johnson Controls, Inc. www.johnsoncontrols.com
P2000 Security Management System Professional Edition Version 3.13 (Continued)
P2000 Edition Feature Comparison
Feature Corporate Edition Professional Edition Express Edition
Workstations 5 (40 maximum) 5 1
Readers 2048 128 32
Cardholders 25,000 (10,000,000 maximum) 25,000 10,000
Real-Time Monitoring
Hours on Site Reporting
Enhanced MIS Interface
Security Threat Level
Area Control
Mustering
Guard Tour
Cabinet Control
High Availability
Video Badging 5 1
Web UI – Alarm and Event Manager
Third-Party Controllers
CCTV Integration
DVR/VMS Integration 1 Type 1 Type
Metasys Integration 1 1
Notifier EU Fire Integration
Alphacom Zenitel Intercom Integration
Commend Intercom Integration 1 1
Aritech EU Intrusion Integration
Bosch Intrusion Integration 10 5
Bosch D6600 Alarm Panel Integration
Elevator Low-Level Interfaces
Elevator High-Level Interfaces
Database Partitioning
Separate Database Server
Archive Report Server
Remote Server Connections
Enterprise Configuration Option (Regional site)
FDA Record Change Tracking
The performance specifications are nominal and conform to acceptable industry standards. For applications at conditions beyond these specifications, consult the local Johnson Controls office.
Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. © 2014 Johnson Controls, Inc. www.johnsoncontrols.com
P2000 Security Management System Professional Edition Version 3.13 (Continued)
Related Documentation Document Title Document Number P2000 Alarm Manager Part No. 24-10786-1
P2000 Archive Report Server Administrator Guide Part No. 24-10786-28
P2000 Archive Report Server User Guide Part No. 24-10786-36
P2000 Database Table Definitions Part No. 24-10786-44
P2000 DVR/VMS Integration Option Manual Part No. 24-10786-52
P2000 Enterprise Configuration Option Manual Part No. 24-10786-60
P2000 Integrated Video Imaging with EPI Builder Manual Part No. 24-10786-87
P2000 Integrated Video Imaging with ID Server Manual Part No. 24-10786-95
P2000 MIS Interface Configuration Manual Part No. 24-10786-109
P2000 Metasys System Integration Manual Part No. 24-10786-117
P2000 Quick Reference Guide Part No. 24-10786-125
P2000 RMS-XML Application Programming Interface Manual Part No. 24-10786-133
P2000 Software Installation Manual Part No. 24-10786-141
P2000 Software Release Notes Part No. 24-10786-168
P2000 Software User Manual Part No. 24-10786-176
P2000 Web Access Manual Part No. 24-10786-184
P2000 HID Global pivCLASS Integration Part No. 24-10786-79
P2000 Web UI Getting Started Part No. 24-10786-192
P2000 Video Badging Option Catalog Page LIT-1900926
P2000 DVR/VMS Integration Catalog Page LIT-1900916
P2000 Intercom Interface Option Catalog Page LIT-1900918
P2000 Enterprise Solution Option Catalog Page LIT-1900919
P2000 Third-Party IP Reader/Controller Integration Catalog Page LIT-1900917
P2000 Bosch Intrusion and D6600 Receiver/Controller Interfaces Catalog Page LIT-1900921
P2000 Otis Compass Destination Elevator System Interface Catalog Page LIT-1900922
P2000 Archive Report Server (ARS) Catalog Page LIT-1900924
P2000 and KONE IP Elevator System Integration Catalog Page LIT-1900923
P2000 High Availability Option Catalog Page LIT-1900938
P2000 WebUI and Mobile Alarm and Event Management Catalog Page LIT-1900939
P2000 Integrations for Europe Catalog Page LIT-1900940
What's New (At a Glance) for P2000 Version 3.13 LIT-12011977
P2000 Bosch Intrusion Interface Product Bulletin LIT-12011978
P2000 and Metasys System Integration Product Bulletin LIT-12011979
P2000 Commend Intercom Interface Option Product Bulletin LIT-12011980
P2000 Third-Party Reader/Controller Integration Product Bulletin LIT-12011981
P2000 Archive Report Server (ARS) Product Bulletin LIT-12011982
| Cardholder Management |
| P2000 Security Management System Professional Edition Version 3.13 |
| P2000 Edition Feature Comparison |
| Web Alarm Management and ID Viewer Mobile Application |
| Alarm Monitoring |
| Real-Time Monitoring |
| P2000 Professional Edition Technical Specifications |
| 1900914 |
| Description |
| Standard Features and Benefits |
| Optional Features and Benefits |
| Software Support Agreements |
| Related Documentation |