GENERAL NOTES - FEDFRAL AVl,A. TION ADMINISTRATION A TCT BASE BUILDl�JG
GENERAL:
1. THE STRUCTUAC DRAWINGS REPRESENT THE COMPLETED STRUCTURE
A',C r.�F NOT INTENDED TO IND ICATE THE MEANS AND METHOD OF CON STr-: 1JC:-IJN.
CODES:
1. 1988 UN IFORM BUILDING CODE (UBC)
2. 1989 BUILD ING CODE FOR THE C ITY AND COUNTY OF DENVER
3. AMER ICAN INST ITUTE OF STEEL CONSTRUCTION (A I SC)" MANUAL
OF STEEL CONSTRUCTION", NINTH EDITION, WHICH INCLUDES
"SPEC IF ICATI ON FOR THE DES IGN , > ABRICATI ON AND ERECTION
OF STRUCTUAL STEEL F OR BUILDINGS AND BRIDGES"
AND "STRUCTUAL JC:NTS US ING A.STM A325 OR A490 BOLTS".
4. AMERICAN WELDING SOC IETY (AW5) "STRUCTUAL WELDING CODE
- STEEL" 01.1, LATEST EDIT ION.
DESIGN LIVE LOADS:
1 ROOF (SNOW) 30 PSF PLUS DR IFT
2. SECOND FLOOR . 150 PSF
3. TH IRD & FUTURE FLOORS 80 PSF
4. STAIRS 100 PSF
5. WIND BASE 80 MPH EXPOSURE C, 1 =1.15
6. EARTHQUAKE SEISMIC ZONE (OWNER'S SPEC IAL REQU IREMENT)
BASE SHEAR V = Z IC W
RW
WHERE Z=O.C75, 1 = 1.25, W = STRUCTURE'S DEAD WE IGHT
C = 2. 75. RW = 8
DESIGN DEAD LOADS:
1. ROOF
2. THIRD & FUTURE FLOORS
3. SECOND FLOOR
4. INTERIOR PARTITIONS
5. EXTERIOR WALLS
DESIGN STRESSES:
100 PSF
88 PSF
99 PSF
20 PSF
75 PSF
1. CONCRETE (28 DAY STRENGTH)
2. REINFORCEMENT:
RE I NFORCEMENT BARS (ASTM A625-GRADE 60) ... FY = 60,000 PS I
WELDED WIRE FABRIC (ASTM A185) ........................ FY = 65,000 PSI
3. STRUCTUAL STEEL:
STRUCTUAL STEEL UNLESS NOTED
OTHER'MSE (ASTM A572, GRADE 50) ..................... FY � 50,000 PSI
STEEL BEAMS AND COLUMNS NOTED
WITH AND ASTERISK ON PLANS AND
SCHEDULED (ASTM A36) ......................................... FY = 36,000 PSI
STEEL ANGLES, BENT PLATES,
BASE PLATES, THREADED RODS (ASTM A36) ........ FY = 36,000 PSI
STEEL TUB ING (ASTM A-500 GRADE B) ................ FY = 46,000 PSI
STEEL PIPE (ASTM A53 TYPE E OR S) ................ FY = 35.000 PSI
STfEL DECK (ASTM A446 GRADE A) ...................... FY = 33,000 PSI
WELDING ELECTRODE LOW-HYDROGEN (E-70) ....... FY = 70,000 PSI
4. GEOTECHNICAL REPORT: "GEOTECHNICAL ENGINEERING STUDY -
FEDERAL AVIATION ADMINISTRATION TRACON FACILITY, PHASE 1 -
DENVER INTERNATIONAL AIRPORT - DENVER, COLORADO", PREPARED
BY CHEN-NORTHERN, INC., DA TED JULY 26, 1989.
CONCRETE CONSTRUCTIOI\I:
1. ALL REINFORCEMENT IS SUPPORTED AND WIRED TOGETHER TO
PREVENT DISPLACEMENT BY CONSTRUCTION LOADS OR BY THE
PLACING OF CONCRETE. ON THE GROUND AND WHERE OTHERWISE
SUBJECT TO CORROSION, USED CONCRETE OR OTHER SUITABLE.
NO•: · CORRODIBLE MATERIAL FOR SUPPORTING REINFORCEMENT
6.. . i.APS CONFORM TO ACI CLASS "C" LAP REQUIREMENTS UNLESS i'!U :cO OTHERWISE.
l
CLASS C LAP SPLICE SCHEDULE
1 --�-- �--
BAR SIZE TOP BARS OTHER BARS
INCHES INCHES
#3 21 15 I
#4 28 20
37 26
44 31 i
#7 55 39
,18 72 51
#9 91 65
#10 115 82
#11 I 142 101
TOP BARS ARE HORIZONTAL BARS OVER MORE THAN 12 INCHES OF
FRESH CONCRETE.
2. MINIMUM CAST-IN-PLACE CONCRETE COVER OVER REINFORCING STEEL,
UNLESS OTHERWISE NOTED.
A. CONCRETE CAST AGAINST AND EXPOSED TO EARTH ............... 3"
B. CONCRETE EXPOSED TO EARTH OR WEATHER:
#6 OR LARGER.......................................................................... 2"
C. CONCRETE NOT EXPOSED TO EARTH OR WEATHER:
SLABS, WALLS:
#11 BAR AND SMALLER........................................................... 3/4"
BEAMS, COLUMNS:
PRIMARY REINFORCEMENT, TIES, SPIRALS ............................... 1-1/2"
3. PROV IDED 6 Mil. THICK POLYETHYLENE VAPOR BARRIER BENEATH ALL
CONCRETE FLOOR SLABS OF THE BUILDINGS. PROVIDED 2-INCH DEPTH
OF CLEAN SAND OVER ALL VAPOR BARRIERS.
4. SEE ALL CONTRACT DRAWINGS FOR ADDrnONAL CONCRETE WORK.
STEEi_ CONSTRUCTION:
1. ALL STRUCTUAL STEEL WORK CONFORM TO TrlE AISC "MANUAL
OF STEEL CONSTRUCTION", 9TH ECITION.
2. SEE ALL CONTRACT DRAWINGS FOR MISCELLANEOUS STEEL
REQUIREMENTS.
3. BOLTS: ALL BOLTS FOR STRUCTUAL <;ONNECTIONS ARE HIGH
STRENGTH BOLTS, EITHER ASIM A325 OR A490. THEY ARE
INSTALLED IN ACOORDANCE WITH THE AISC SPECIFICATION
4.
FOR "STRUCTUAL JOINTS USING ASTM A325 OR A490 BOLTS"
AND A�E FIELD TESTED AND INSPECTED IN ACCORDANCE WITH
SECTION 9. ALL HIGH-STRENGTH BOLTS HAVE DIRECT TENSION
INDICATORS OR ARE LOAD INDICATOR BOLTS. ALL OTHER BOLTS
ARE ASTM A307 AND ARE PROVIDED �nTH LOCK WASHERS UNDER
NUTS OR SELF-LOCKING NUTS.
WELDED HEADED STUDS: ALL STUDS ARE 3/4 INCH DIAMETER
BY 4 INCHES AT 2 INCH STEEL DECK AND :3/4 INCH DIAMETER
BY 5 INCH LONG AT 3 INCH STEEL DECK, UNLESS OTHERWISE
NOTED. STEEL BEAMS SUPPORTING A CAST-!N-PLACE CONCRETE
SLAB HAVE STUDS AT 2'-0" ON CENTER, UNLESS OTHERWISE
NOTED. STEEL STUD ANCHORS WELDED TO STEEL SEAMS OR
CONCRETE CONNECTIONS HAVE SHEAR AND TENSILE CAPACITY PER
ANCHOR OF 13.3 KIPS AND 19.4 KIPS RESPECTIVELY.
STEEL DECK:
1. STEEL COMPOSITE AND NONCOMPOSITE DECK CONFORM TO THE
RECOMMENDATIONS AND SPECIFICATIONS OF THE STEEL DECK
INSlllUTE . STEEL DECK AND ALL OF ITS FLASHINGS CONFORM
TO ASTM A446, GRADE A. SPAN OVER FOUR SUPPORTS (CONTINUOUS)
OVER THREE OR MORE SPANS), EXCEPT WHERE THE FRAMING DOES
NOT PERMIT. ALL WELDING IN ACCORDANCE WITH AWS D1.3 SPECIFICATION
FOR "WELDING SHEET STEEL IN STRUCTURES."
2. COMPOSITE DECK: CONCRETE BONDING-TYPE UNITS ARE FORMED
WITH DEFORMATIONS TO PROVIDE ON INTERLOCK BETWEEN THE
CONCRETE AND STEEL. COMPOSITE UNITS ARE FASTENED TO
THE STEEL SUPPORTS AT THE ENDS OF THE UNITS AND TO THE
INTERMEDIATE SUPPORTS WITH THREE 3/4-INCH DIAMETER PUDDLE
WELDS (1/2 INCH EFFECTIVE) EPR 2'-0" OF WIDTH. WHERE TWO
UNITS ABUT, EACH UNIT IS SO FASTENED TO THE STEEL SUPPORTS.
THE SIDE LAPS OF ADJACENT UNITS IS FASTENED BETl•IEEN SUPPORTS
PARALLEL TO THE DECK SPAN WITH 3/4 INCH DIAMETER PUDDLE WELDS
AT 1'-C" ON CENTER UNLESS OTHERWISE NOTED. VENT TABS ARE
PROVIDED WHERE FLUID-APPLIED MEMBRANE IS TO BE PLACED OVER
CONCRETE FILL. SHEAR STUDS WELDED THROUGH DECK MAY HA VE BEEN
USED IN PLACE OF 3/4 INCH DIAMETER PUDDLE WELDS. PROVIDED
18 GAUGE FLASHING AND CLOSURE PLATES AT WALL ENDS OF ALL
UNITS, AROUND COLUMNS AND AT ALL PERIMETER LOCATIONS
REQUIRING CLOSURE. ALL 2 INCH AND 3 INCH DECK HA VE A MOMENT OF
INERTIA OF 0.428 AND 0.950 INCHES TO THE FOURTH POWER
RESPECTIVELY AND A SECTION MODULUS OF 0.368 AND 0.570
INCHES CUBED RESPECTIVELY. ALL DECK HAVE A SHEAR CAPACITY
OF 700 PLF.
PRECAST CONCRETE PANELS:
1. THE CONNECTION DETAILS FOR ARCHITECTUAL PRECAST PANELS ARE
SCHEMATIC. DESIGN CRITERIA AND LOADING REFER TO SPECIFICATION
"BASE BUILDING" SECTION 03411.
l--+---+---·-----------------+----+------11
REV DATE DESCRIPTION
DEPARTMENT OF TRANSPORTATION
CHi:CK APRV'D
FEDERAL AViATION ADMINISTRATION
NORTHWEST MOUNTAIN REGION - SEATTLE, WASHINGTON
DENVER, COLORADO
DENVER INTERNATIONAL AIRPORT
ATCT BASE BUILDING
DESIGN CRITERIA AND
GENERAL NOTES
R .... EY-
IE-W-ED_B_Y"'s'u""�;:-;;;1n"'E"'Dc:-,:B,-;Y---------, -cA:;;Pc;, s,,.y,-t--+����·· -jjc�eL.....__ C,....�-� PROJECT ENGINEER. ANM 4548C1 SUPV: - ·'"' i 1·' ..... T n11"0 c-cM
DES IGNED ISSUED BY 7, /, / "i� I---+--+-------, AIRWAY FACILITIES fcc:-3:,L.f.2''----------1
DRAWN DIVISION DRAWING NO.
CHECKED AN'A-400 NMD- 600-40478-S0.1 A
Amendment 1 - IV
File details come from the government source that posted it. Updated .