C C " cc e u " ·a
H
G
F
E
D
C
B
7 6 5 4 3 I
I -- ---
BUEC LOCATION
40° 03'48"N, 79° 15'41"W
DEPARTMENT OF TRANSPORTATION
FEDERAL AVIATION ADMINISTRATION
EASTERN SERVICE AREA
I I
I
I ,, I I
I \ I
I I
I
I KOOSS/
I
I, •
I
I
LOCATION MAP
'',, l(OQStR STATE PARK
H
G
F
E
BACK-UP EMERGENCY COMMUNICATIONS (BUEC)
TOWER REPLACEMENT AND UPGRADES
BAKERSVILLE, PENNSYLVANIA CAR1) D
7 3
C
FOR OFFICIAL USE ONLY
PUBLIC AVAILABILITY TO BE DETERMINED UNDER 5 USC 552
04/08/2016 CONSTRUCTION, WR *14659 1003172 06/24/2015
REV
APPROVED
DATE
DESCRIPTION
DEPARTMENT OF TRANSPORTATION
FEDERAL AVIATION ADMINISTRATION �
ATO - TECHNICAL OPERATIONS EASTERN SERVICE AREA g '"i-----------------�-----��-
BUEC � I
0 0
TOWER REPLACEMENT AND UPGRADES ��
BAKERSVILLE
COVER SHEET· �
!!l
PA
REVIEWED BY
SUBMITTED BY �
ev-
Un APPROVED BY ctr A�
J.TIMONY M.GORDO
PROJECT ENGINEER MGR: ENGINEERING - CENTER C
DESIGNED ISSUED BY DATE JCN
>---+------+-c-oR-AWN--� JT ENGINEERING SERVICES ""'0RA=w1N=-G
-N��108=12=01=6 - -�
=3�-�
CHECKED �� COMMUNICATIONS AR1_10031?Z-G001
;2 w
DTFAEN-16-R-00130 Attachment 1a
Linda Hennequant Stamp for Specs
H
G
F
E
D
C
B
A
DRAWING NUMBER
AR1-1003172-G001
AR1-1003172-G002
AR1-1003172-G003
AR1-1003172-C001
AR1-1003172-C002
AR1-1003172-C003
AR1-1003172-C004
AR1-1003172-C005
AR1-1003172-E001
AR1-1003172-E002
AR1-1003172-E003
AR1-1003172-0FP001
DRAWING LIST
DRAWING TITLE
COVER SHEET
INDEX SHEET
GENERAL NOTES
COAX CABLE INSTALLATION DRAWING
PROPOSED SITE PLAN
PLATFORM AND SWING ARM DETAILS
PLATFORM PLAN
FENCE DETAILS
ANTENNA PLATFORM JUNCTION BOX AND GROUND BAR DETAILS
SHELTER JUNCTION BOX DETAILS
LIGHTNING PROTECTION & GROUNDING DETAILS
EQUIPMENT ROOM LAYOUT
7 6
A A-G
AGL
ALS
AN!
ADA
ARP
AWG
AWOS
B/U
BGL
BLD
BSCU
BUEC
C
CE/CET
CFW
CND
co
COTR
CVPS
DEB
DIA
DISC
DIM
DME
DME CO
DOT
DPST
DPU
DU
DVOR
DWG
E/G
EES
EL ( ELEV l
EMT
EOR
FAA
FBO
FDN
FHA
FOO
FS (F.S.)
FT
GA
GALV
GFC!
GFM
GND
GP
GRSC
HS (H.S.)
HV
HVAC
!LS
IN
INSUL
KV
KVA
LCU
LHA
LIR
LDC
MALS
MAS LR
MAX
MB
MG
MM
MP
MS
MSL
MUTCD
N N/A
NAS
NBP
NOB
NEC
NOT AM
NS ( N. S. )
NWS
OB
ODALS
OFA
ORE IL
p
PAPI
PNL
PR
PRIM
R/W
RAIL
RADAR
RCAG
RCO
RE
RECEPT
REIL
REL
REQ
RF
RMMS
RMS
RR
RRCS
RSA
RTR
s
SA
SCH
SEC
SEC LT
SMO
SPD
SPST
ss
SSC
STA
T
T/W
TACAN
AMP
AIR TO GROUND
ABOVE GROUND/GRADE LEVEL
APPROACH LIGHT SYSTEM
NAS IMPLEMENTATION (FAA)
AIR OPERATIONS AREA
AIRPORT REFERENCE POINT
AMERICAN WIRE GAUGE
ABBREVIATIONS
AUTOMATED WEATHER OBSERVATION SYSTEM (NWS)
BACKUP
BELOW GROUND/GRADE LEVEL
BUILDING
BARE SOLID COPPER
BACK-UP EMERGENCY COMMUNICATIONS
CONTROL
CONSTRUCTION ENGINEER/CIVIL ENGINEERING TECHNICIAN (TSSCJ
CENTERFIELD WIND
CONDUIT (DUCT)
CONTRACTING OFFICER (FAA)
CONTRACTING OFFICER'S TECHNICAL REPRESENTATIVE (FAA)
CENTRAL VERMONT PUBLIC SERVICE CORPORATION
DIRECT EARTH BURIAL
DIAMETER
DISCONNECT
DIMENSION
DISTANCE MEASURING EQUIPMENT
DME CORPORATION
DEPARTMENT OF TRANSPORTATION
DOUBLE POLE, SINGLE THROW
DATA PROCESSING UNIT
DISTRIBUTION UNIT
DOPPLER VOR
DRAWING
ENGINE GENERATOR
EARTH ELECTRODE SYSTEM
ELEVATION
ELECTRIC METALLIC TUBING
END OF RUNWAY
FEDERAL AVIATION ADMINISTRATION (US DOT)
FIXED BASE OPERATOR
FOUNDATION
FEDERAL HIGHWAY ADMINISTRATION (US DOT)
FOREIGN OBJECT DEBRIS
FAR SIDE
FEET
GENERAL AVIATION
GALVANIZED
GROUND FAULT CIRCUIT INTERRUPTER
GOVERNMENT FURNISHED MATERIAL
GROUND
GENERAL PURPOSE
GALVANIZED RIGID STEEL CONDUIT
HIGH STRENGTH
HIGH VOLTAGE
HEATING, VENTILATION, AND AIR CONDITIONING
INSTRUMENT LANDING SYSTEM
INCH
INSULATED
KILOVOLT
KILOVOLT AMPERE
LINK CONTROL UNIT (RMS)
LAMP HOUSING ASSEMBLY (PAPI, VASI)
LOW IMPACT RESISTANCE
LOCALIZER (!LS)
MEDIUM INTENSITY APPROACH LIGHTING SYSTEM
MALS WITH RUNWAY ALIGNMENT INDICATOR LIGHTS (MALS-RAIL)
MAXIMUM
MACHINE BOLT
MAST-ON-GROUND (L!Rl
MIDDLE MARKER ( !LS)
MULTI-POINT (GROUND)
MAST-ON-STAND (LIR)
MEAN SEA LEVEL
MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (FHA)
NEUTRAL
NOT APPLICABLE
NATIONAL AIRSPACE SYSTEM
NEW BEDFORD PANORAMICS CORPORATION
NON-DIRECTIONAL BEACON
NATIONAL ELECTRIC CODE
NOTICE TO AIRMEN
NEAR SIDE
NATIONAL WEATHER SERVICE
OBSTRUCTION
OMNI-DIRECTIONAL APPROACH LIGHT SYSTEM
OBJECT FREE AREA
OMNI-DIRECTIONAL RUNWAY END IDENTIFIER LIGHTS
POWER
PRECISION APPROACH PATH INDICATOR
PANEL
PAIR
PRIMARY
RUNWAY
RUNWAY ALIGNMENT INDICATOR LIGHTS
RADIO DETECTION AND RANGING
REMOTE CENTER AIR TO GROUND COMMUNICATIONS
REMOTE COMMUNICATIONS OUTLET
RESIDENT ENGINEER (FAA/TSSC)
RECEPTACLE
RUNWAY END IDENTIFIER LIGHTS
RUNWAY EDGE LIGHTS
REQUIRED
RADIO FREQUENCY
REMOTE MAINTENANCE MONITORING SYSTEM
REMOTE MONITORING SUBSYSTEM
REMOTE RADIO
REMOTE RADIO CONTROL SYSTEM
RUNWAY SAFETY AREA
REMOTE TRANSMITTER/RECEIVER
SIGNAL
SUBCONTRACTS ADMINISTRATOR (TSSC)
SCHEDULE
SECONDARY
SECURITY LIGHT
SYSTEM MANAGEMENT OFFICE (FAA)
SURGE PROTECTION DEVICE
SINGLE POLE, SINGLE THROW
STAINLESS STEEL
SYSTEM SUPPORT CENTER (FAA)
STATION
TELEPHONE
TAXIWAY
TACTICAL AIR NAVIGATION
5 4
TEL
TEL CO
TH
TPST
TSA
TSSC
TVSS
TYP
UPS
us
V
VASI
VHF
VOR
VORTAC
WI
WILCOX
WPN
ws
XFMR
XMTR
TAXIWAY EDGE LIGHTS
TELEPHONE COMPANY
THRESHOLD
TRIPLE POLE, SINGLE THROW
TAXIWAY SAFETY AREA
FAA TECHNICAL SUPPORT SERVICE CONTRACT (PARSONS)
TRANSIENT VOLTAGE SURGE PROTECTION
TYPICAL
UNINTERRUPTIBLE POWER SOURCE/SUPPLY
UNITED STATES
VOLT
VISUAL APPROACH SLOPE INDICATOR.
VERY HIGH FREQUENCY
VHF OMNI-DIRECTIONAL RANGE
VHF OMNI-DIRECTIONAL RANGE WITH TACAN
WITH
WILCOX CORPORATION (THALES)
WILCOX PART NUMBER (WILCOX CO)
WIND SOCK
TRANSFORMER
TRANSMITTER
SYMBOLS LEGEND
SUBTITLE REFERENCE
REFERENCE NUMBER/LETTER
<PLAN, DETAIL I ELEVATION, SECTION)
/' X" XXXXXXXXXXX
'xxxx I SCALE: X·XXX
"-scALE
SHEET NUMBER($) WHERE CALLOUT(Sl TO PLAN, DETAIL, ELEVATION OR SECTION IS/ARE LOCATED
ELEVATION CALLOUT REFERENCE
ELEVATION REFERENCE LETTER
�T '"'"'" ""'"'
ELEVATION IS LOCATED
SECTION CALLOUT REFERENCE
SECTION REFERENCE LETTER
�SHEET NUMBER WHERE
SECTION IS LOCATED
I
DETAIL CALLOUT REFERENCE
X
' I
I XXYX IX '," ;.,
DETAIL REFERENCE NUMBER
�HEET NUMBER WHERE
DETAIL IS LOCATED
DRAWING PREFIXES
CXXX - CIVIL
EXXX - ELECTRICAL/ELECTRONIC
GXXX - GENERAL
DXXX - EQUIPMENT
SXXX - STRUCTURAL
FOR OFFICIAL USE ONLY
PUBLIC AVAILABILITY TO BE DETERMINED UNDER 5 USC 552
04/08/2016 CONSTRUCTION, WR •14.659 1003172 06/24/2015
H
G
F
E
D
C
RE V APPRO VED
DATE DESCRIPTION JCN REDLINE
DATE APVD B
I 3
DEPARTMENT OF TRANSPORTATION
FEDERAL AVIATION ADMINISTRATION
ATO - TECHNICAL OPERATIONS EASTERN SERVICE AREA
BUEC
TOWER REPLACEMENT AND UPGRADES
INDEX SHEET
BAKERSVILLE
R_E _VIE_ W
ED
BY
SUBMITTED BY
J.TIMONY
PROJECT ENGINEER
DESIGNED ISSUED BY
1--1--f-DR-A -WN----=-<
JT
ENGINEERING SERVICES
CHECKED
I 2
DG COMMUNICATIONS
JT
..--- PA
MGR: ENGINEERING - CENTER C
DATE 04/08/2016 IJCN 1003172
DRAWING NO REV
AR1-1003172-G002
z a: '" I- m V) 5 z 0
0 0
0 \£
V)
A� N
N �
L aw
DTFAEN-16-R-00130 Attachment 1a
F
E
D
C
B
A
8 7
GENERAL NOTES:
1. THIS DRAWING PACKAGE INDICATES WORK REQUIRED FOR THE TOWER REPLACEMENT
AND UPGRADES AT THE BACK-UP EMERGENCY COMMUNICATIONS (BUEC)
FACILITY IN BAKERSVILLE, NY.
2. SUBCONTRACTOR ACCESS ROUTES, STAGING AREAS, AND REGIONAL EMPLOYEE
PARKING AREAS SHALL BE APPROVED IN ADVANCE BY THE FAA.
3. WORK ASSOCIATED WITH THE BUEC FACILITY MAY REQUIRE A SHUTDOWN.
COORDINATE ALL BUEC RELATED ACTIVITIES AND REQUIRED SHUTDOWNS WITH
THE FAA SSC AT LEAST 48 HOURS IN ADVANCE,
4. THE SUBCONTRACTOR SHALL MAINTAIN A CLEAN WORK SITE, EQUIPMENT ANO
MATERIAL SHALL BE REMOVED FROM THE WORK SITE AT THE END OF EACH
WORK SHIFT. THE SUBCONTRACTOR SHALL KEEP THE WORK SITE FREE OF
CONSTRUCTION DEBRIS.
5. THE SUBCONTRACTOR SHALL STRICTLY COMPLY WITH ALL OSHA REGULATIONS
AT ALL TIMES, THE RE RESERVES THE RIGHT TO SUSPEND THE PROJECT
SHOULD HE OR SHE DETERMINE THAT AN UNSAFE CONDITION EXISTS.
6. THE SUBCONTRACTOR SHALL PROVIDE AND INSTALL ALL MATERIAL UNLESS
OTHERWISE INDICATED. THE SUBCONTRACTOR SHALL PROVIDE ALL LABOR,
EQUIPMENT, AND REQUIRED TEMPORARY POWER UNLESS OTHERWISE INDICATED,
, THE SUBCONTRACTOR SHALL BE RESPONSIBLE FOR ALL REQUIRED PERMITS.
7. THE SUBCONTRACTOR SHALL LEGALLY DISPOSE OF ALL MATERIAL AND
EQUIPMENT NOT RETURNED TO OR RETAINED BY THE FAA.
8. IF CONDITIONS ARE DIFFERENT THAN THOSE INDICATED IN THE DRAWINGS
OR SPECIFICATIONS, THE SUBCONTRACTOR SHALL CONTACT THE SUBCONTRACT
ADMINISTRATOR (SA) PRIOR TO PROCEEDING WITH CONSTRUCTION.
SITE WORK:
1. NOT USED
2. ALL DIMENSIONS, ELEVATIONS, CONTOURS, AND HEIGHTS INDICATED ARE
APPROXIMATE AND SHALL BE VERIFIED IN THE FIELD BY THE SUBCONTRACTOR.
3. EXISTING UTILITY LOCATIONS SHOWN ARE APPROXIMATE. OTHER UTILITIES
MAY NOT BE SHOWN. THE SUBCONTRACTOR SHALL FIELD LOCATE ALL SUBSURFACE
UTILITIES PRIOR TO ANY EXCAVATION. FORTY-EIGHT (48) HOUR <MINIMUM)
NOTICE BY THE CONTRACTOR TO THE RE, AND THE FAA SSC IS REQUIRED
FOR ALL UTILITY MARKING AND/OR FACILITY SHUTDOWNS.
4. THE SUBCONTRACTOR SHALL BE PREPARED TO IMMEDIATELY REPAIR ANY
UTILITIES DAMAGED DURING EXCAVATION OPERATIONS AND SHALL CONDUCT
ALL SUCH REPAIRS AT SUBCONTRACTOR EXPENSE.
5, ALL UNDERGROUND CABLE SHALL BE IN CONDUIT EXCEPT FOR BARE COPPER
GROUND CABLE, GUARD WIRE, COUNTERPOISE, AND WHERE OTHERWISE
INDICATED. UNDERGROUND CONDUIT SHALL BE 24 INCHES (MINIMUM) BELOW
GRADE EXCEPT WHEN INTERFACING HANOHOLE ENTRANCES OR EXISTING
CONDUIT AT OTHER DEPTHS OR WHERE OTHERWISE INDICATED. UNDERGROUND
CONDUIT SHALL BE GALVANIZED RIGID STEEL CONDUIT (GRSC) EXCEPT
WHERE OTHERWISE INDICATED. GRSC FITTINGS SHALL BE THREADED TYPE.
EXPOSED THREADS SHALL BE SEALED WITH AN APPROVED SEALANT, PRIOR
TO BACKFILL OPERATIONS, TO PREVENT CORROSION. CONDUITS SHALL
BE CLEANED OF DEBRIS, AND A NYLON PULL WIRE SHALL BE INSTALLED
IN ALL CONDUITS.
6. ALL EXTERIOR CONDUITS ENTERING BUILDINGS (EXCEPT THOSE WITH
GROUNDING CONDUCTORS ONLY) SHALL HAVE EXPANSION COUPLINGS. AN
APPROVED GROUND JUMPER SHALL BE INSTALLED BETWEEN METALLIC
CONDUIT ON EACH SIDE OF COUPLING UNLESS COUPLING JS INTERNALLY
GROUNDED.
7. CONCRETE CABLE/DUCT MARKERS SHALL BE INSTALLED WHERE INDICATED
ON THE DRAWINGS AND BY THE RE. CABLE/DUCT MARKERS SHALL BE
PIGMENTED ORANGE AND SHALL NOT EXTEND MORE THAN 1 INCH ABOVE
FINAL GRADE,
8. BACKFILL FOR CABLE OR DUCT TRENCHES OR FOR OTHER EXCAVATIONS
SHALL BE PLACED IN LAYERS NOT EXCEEDING 8 INCHES, AND EACH LAYER
SHALL BE THOROUGHLY COMPACTED TO WITHIN 95% OF MAXIMUM DENSITY
OF OPTIMUM MOISTURE CONTENT IN ACCORDANCE WITH AASHTO T-180.
WHERE FILL IS REQUIRED IN THE RUNWAY/TAXIWAY SAFETY AREA,
WORK SHALL COMPLY WITH FAA AC 150/5370-10. IF REQUIRED, THE
SUBCONTRACTOR SHALL ARRANGE FOR AN INDEPENDENT FIELD TEST TO
VERIFY PROPER COMPACTION.
9. THE EXISTING GRADE SURROUNDING FOUNDATION OR TRENCH WORK SHALL
BE STABILIZED AND PROTECTED FROM EROSION DURING AND IMMEDIATELY
AFTER COMPLETION OF THE FOUNDATION OR CONDUIT INSTALLATION AND
ALL REQUIRED EXCAVATION AND BACKFILL.
10. ALL DISTURBED AREAS SHALL BE RESTORED TO PRIOR CONDITION AT A
MINIMUM. FINAL CONDITION SHALL BE APPROVED BY THE FAA.
11, ALL EXCAVATIONS WITHIN 10' OF BUEC SHELTER SHALL BE PERFORMED
BY HANO.
8 7
6 5
TOWER DESIGN, FABRICATION, AND INSTALLATION:
2.
THE TOWER PLATFORM FURNISHED BY THE SUBCONTRACTOR SHALL BE COMPLETE IN
ACCORDANCE WITH ALL SPECIFICATION REQUIREMENTS INCLUDING STRUCTURAL
BOLTS, AND ALL OTHER HARDWARE ESSENTIAL FOR ERECTING THE TOWER. THE
SUBCONTRACTOR SHALL PROVIDE ALL MATERIALS, SUPPLIES, EQUIPMENT, AND
SERVICES NECESSARY TO DESIGN, FABRICATE, DELIVER, AND ERECT EACH TOWER.
THE TOWER SHALL BE SELF-SUPPORTING TYPE WITH A PLATFORM AT THE
TOP FOR MOUNTING AND SERVICING ANTENNAS. THE TOWER SHALL BE
DESIGNED TO BE SHIPPED KNOCKED DOWN AND TO BE ERECTED IN THE
FIELD USING STRUCTURAL BOLTS ONLY.
3. THE TOWER PLATFORM SHALL PERMIT INSTALLATION OF VIV DOUBLE STACK
ANTENNAS. ACCESS TO THE PLATFORM SHALL BE EQUIPPED WITH AN OSHA
APPROVED CLIMBING LADDER WITH 3/4" MINIMUM DIAMETER RUNGS (OR OSHA
REQUIREMENT), WHICHEVER IS LARGER, THE PLATFORM SHALL BE CONSTRUCTED OF
ANGLE FRAMING MEMBERS AND THE FLOOR SHALL BE FABRICATED FROM BAR
TYPE GRATING, SERRATED 1" X 3/16" BEARING BARS MINIMUM, 1 3/16" ON
CENTER, REGULAR CROSS BARS SPACED 2" ON CENTER. THE FLOOR SHALL BE
SECURED TO THE FRAMING. THE PLATFORM SHALL BE PROVIDED WITH A GUARD
RAIL SYSTEM, COMPOSED OF VERTICAL POSTS WITH TOP AND INTERMEDIATE RAIL
COMPONENTS LOCATED 42 INCHES AND 21 INCHES, RESPECTIVELY, ABOVE THE
PLATFORM FLOOR. A 4 INCH HIGH TOE-BOARD SHALL BE ATTACHED TO THE BASE
OF THE RAIL POST. THE PERIMETER FRAMING MEMBERS SHALL SUPPORT THE RAIL
AS WELL AS THE REQUIRED ANTENNA MOUNTING BRACKETS.
4. THE TOWERS SHALL BE DESIGNED FOR A WINO LOAD PER ANSI STANDARD
TIA-222-G TO SUPPORT THE PLATFORM WITH A 42 INCH HANDRAIL PLUS
THE FOLLOWING:
A. SIX (6) VHF/VHF DOUBLE STACK ANTENNAS, MOUNTED OUTSIDE THE
PLATFORM HANDRAIL ON SWING ARMS.
B. ONE JUNCTION BOX MOUNTED ON THE PLATFORM HANDRAIL.
C. TWELVE ANTENNA CABLES, EACH 1 INCH DIAMETER, ROUTED UP ONE
SIDE OF THE TOWER,
5. ALL BOLTS FOR STRUCTURAL JOINTS SHALL BE HIGH STRENGTH PER
ASTM A-325. ALL NUTS SHALL HAVE A JAM NUT BENEATH THE FULL
NUT. SELF-LOCKING NUTS INTENDED FOR USE ON EXTERIOR BOLTED
CONNECTIONS MAY BE SUBMITTED FOR APPROVAL.
6, THE SUBCONTRACTOR SHALL SUBMIT DETAILED DESIGN, FABRICATION, AND
ERECTION DRAWINGS FOR THE TOWERS. THE DRAWINGS AND CALCULATIONS
SHALL BE IN ACCORDANCE WITH ESTABLISHED ENGINEERING PRACTICE AND
THE AC!, AISC, AISI, OR EIA SPECIFICATIONS AS APPLICABLE. DESIGN
DRAWINGS SHALL SHOW CONTROL DIMENSIONS, MEMBER SIZES, AND OTHER
DETAILS NECESSARY FOR THE DEVELOPMENT OF SHOP AND ERECTION
DRAWINGS. ERECTION DRAWINGS SHALL INDICATE ANCHOR BOLTS, MEMBER
LOCATION, BOLT SIZES AND NUMBER AND ALL OTHER INFORMATION TO
CLEARLY DEPICT REQUIREMENTS FOR FIELD ERECTION. A PARTS LIST
SHOWING THE MEMBER NUMBER, SIZE, AND LENGTH SHALL BE PROVIDED
IN THE ERECTION DRAWINGS.
7. TOWER FABRICATION SHALL BE IN ACCORDANCE WITH THE AJSC AND THE
SPECIFICATIONS. MEMBERS SHALL HAVE NO SHARP EDGES WHICH WILL BE
HAZARDOUS DURING HANDLING OR OTHER IRREGULARITIES WHICH WILL
INTERFERE WITH ERECTION. THE SUBCONTRACTOR SHALL BE RESPONSIBLE
FOR CORRECTIONS OF ALL FABRICATION ERRORS AND CORRECT FITTING
OF THE FABRICATED MEMBERS. EACH SEPARATE MEMBER, EXCEPT BOLTS,
WASHERS, AND SIMILAR ITEMS SHALL BE CLEARLY MARKED AS PER THE
ERECTION DRAWINGS.
8. TOWER PLATFORM SHALL BE FULLY GRATED.
9. FINAL TOWER DESIGN SHALL BE 100% STRUCTURALLY ANALYZED AND STAMPED
APPROVED BY A LICENSED PROFESSIONAL ENGINEER WITHIN THE CONTINENTAL
U.S. THE TOWER SHALL BE ANALYZED IN ITS ENTIRETY, INCLUDING, BUT
NOT LIMITED TO; PLATFORM, SWING ARMS, ANTENNA MOUNTS, JUNCTION
BOXES, WAVEGUIDE LADDER AND CABLES, ANTENNAS, CLIMBING LADDER, AND
CONDUITS, INCLUSIVE OF ALL APPURTENANCE LOADINGS, ETC. THE ANTENNA
MOUNTS AND SWING ARM DESIGN SHALL BE ANALYZED AND STAMPED APPROVED
TO SUPPORT DOUBLE VIV TACO ANTENNAS.
10. PROVIDE 'APPROVED' DETAILED TOWER DESIGN/MANUFACTURER SHOP DRAWINGS
TO TOWER P.E. FOR STRUCTURAL ANALYSIS.
ELECTRICAL WORK:
1. ALL ELECTRICAL WORK SHALL CONFORM TO FAA-C-1217F AND FAA-C-1391C
SPECIFICATIONS AND IN NO CASE SHALL VIOLATE THE NATIONAL ELECTRIC
CODE (NFPA 70, NEC).
2. THE SUBCONTRACTOR SHALL MAKE ALL POWER AND GROUND TERMINATIONS. COAX
CABLE AND CONNECTORS PROVIDED AND INSTALLED BY SUBCONTRACTOR. ALL
FLEXIBLE LJQUJDTIGHT CONDUIT SHALL BE PLASTIC PVC LIQUID TIGHT TYPE.
ALL CONTROL/DATA CABLE SHALL BE TWISTED, INDIVIDUALLY SHIELDED.
3. ALL CIRCUITS SHALL HAVE INDIVIDUAL NEUTRAL AND GROUNDING CONDUCTORS;
NO SHARED NEUTRALS OR GROUNDS WILL BE PERMITTED.
4. NEUTRAL CONDUCTORS SHALL REMAIN ISOLATED FROM GROUND IN ALL LOCATIONS
EXCEPT AT POWER SERVICE ENTRANCE. WHERE POSSIBLE, POWER CABLES AND
CONTROL/DATA CABLES SHALL RUN IN CONDUIT INDEPENDENT OF EACH OTHER.
SEPARATE POWER AND CONTROL/DATA CABLES IN COMMON HANDHOLES, ENCLOSURES,
AND SHELTER SQUARE DUCT WIREWAY.
5. ALL CABLES SHALL BE PROPERLY COLOR CODED AND PERMANENTLY LABELED AT
EACH END AND IN EACH HANDHOLE. ALL CABLES IN HANDHOLES SHALL BE LOOPED
AROUND SEVERAL TIMES.
ELECTRICAL GROUNDING:
1. GROUNDING AND LIGHTNING PROTECTION SHALL MEET FAA STANDARD 019E,
"LIGHTNING PROTECTION, GROUNDING, BONDING AND SHIELDING REQUIREMENTS
FOR FACILITIES".
2. ALL GROUND RODS SHALL BE COPPER CLAD STEEL, 3/4 INCH DIAMETER AND
10 FEET LONG, GROUND RODS SHALL BE DRIVEN SUCH THAT THE TOP OF ROD
IS NO LESS THAN 12 INCHES BELOW GRADE,
3. ALL UNDERGROUND GROUND CONNECTIONS SHALL BE EXOTHERMICALLY WELDED
UNLESS OTHERWISE INDICATED.
4.
5.
6.
ALL UNDERGROUND GRSC SHALL BE BONDED BY A #4/0 AWG BARE COPPER GROUND,
EXOTHERMICALLY WELDED TO THE CONDUIT, THE GROUNDING COUNTERPOISE,
AND/OR GROUND ROD AT EACH END.
UNDERGROUND GROUNDING CONDUCTORS SHALL BE 24 INCHES (MINIMUM) BELOW
GRADE EXCEPT AT GROUND RODS AND AS OTHERWISE INDICATED.
ADDITIONAL GROUNDING NOTES ON DRAWING AR1-1003172-E003.
4 3 2 1
STRUCTURAL STEEL & WELDING:
2.
ALL STRUCTURAL STEEL SHALL BE DETAILED, FABRICATED, AND ERECTED IN ACCORDANCE WITH THE 13TH EDITION OF AISC "SPECIFICATION FOR DESIGN, FABRICATION, AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS".
ALL STRUCTURAL STEEL SHALL BE HOT DIP GALVANIZED IN ACCORDANCE WITH ASTM STANDARD
ARE USED, THE HOT DIP GALVANIZING SHALL ALSO BE PROVIDED ON THE INSIDE SURFACES.
AFTER FABRICATION. TOUCH UP IN THE FIELD WITH TNEME-ZINC #90-97 URETHANE ORGANIC
IN ACCORDANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONS.
A123. IF HSS OR TUBE SECTIONS
THE GALVANIZING SHALL BE APPLIED
ZINC RICH PRIMER. PREPARE SURFACE
3. STRUCTURAL STEEL FOR WIDE FLANGE, PLATES, ANGLES, AND CHANNELS SHALL CONFORM TO ASTM A36, EXCEPT AS OTHERWISE NOTED.
4, STRUCTURAL STEEL HSS ROUND OR RECTANGULAR SHAPES SHALL CONFORM TO ASTM A500, GRADE B, SEAMLESS, EXCEPT AS OTHERWISE
NOTED.
FOUNDATION WORK:
1. ANCHOR BOLTS SHALL BE HD GALVANIZED IN ACCORDANCE WITH ASTM A153 AND MEET OR EXCEED THE REQUIREMENTS OF ASTM F1554-S2, S5 GRADE 105 AND SHALL BE TIGHTENED TO A SNUG TIGHT CONDITION (FULL EFFORT OF A MAN USING AN ORDINARY
SPUD WRENCH).
2. NUT LOCKING DEVICE SHALL BE INSTALLED ON ANCHOR BOLTS.
3, ALL ANCHOR BOLTS SHALL BE SET BY TEMPLATE BEFORE THE CONCRETE IS PLACED.
4, CONCRETE CONSTRUCTION SHALL CONFORM TO THE LATEST EDITION OF AC! 301 AND AC! 318. ALL CAST-IN-PLACE STRUCTURAL CONCRETE SHALL BE IN ACCORDANCE WITH AC! AND SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF F'C=4000 PSI AT 28
DAYS (NORMAL WEIGHT), OR AS SPECIFIED BY TOWER MANUFACTURER DESIGN.
5. REINFORCING STEEL- ALL DETAILING, FABRICATION, AND ERECTION OF REINFORCING BARS, UNLESS NOTED OTHERWISE, SHALL BE IN ACCORDANCE WITH THE MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES (AC! 315), LATEST EDITION. ALL REINFORCEMENT SHALL BE NEW BILLET STEEL, DEFORMED BARS, CONFORMING TO ASTM A615, GRADE 60 WITH A MINIMUM YIELD STRENGTH OF Fy=60,000 PSI. SPLICES IN REINFORCEMENT SHALL NOT BE ALLOWED UNLESS OTHERWISE INDICATED.
6. EXPOSED EDGES OF CONCRETE SHALL HAVE 1" CHAMFER.
7. TOP OF FOUNDATION EXPOSED TO WEATHER SHALL BE SLOPED FROM THE CENTER OF THE OUTSIDE EDGE OF A MINIMUM OF 1/4" PER
FOOT, PROVIDE A FLOATED FINISH.
8. CONCRETE SHALL BE PLACED AGAINST UNDISTURBED SOIL WHEN FOUNDATION IS BEARING ON SOIL.
9. CONCRETE SHALL BE PLACED IN A MANNER THAT WILL PREVENT SEGREGATION OF CONCRETE MATERIALS AND OTHER OCCURRENCES WHICH
MAY DECREASE THE STRENGTH OR DURABILITY OF THE FOUNDATION.
10. WELDING IS PROHIBITED ON REINFORCING STEEL AND EMBEDMENT.
11. MAXIMUM AGGREGATE SIZE SHALL NOT EXCEED 3/4".
12. THE TOWER FOUNDATION DESIGN SHALL BE DESIGNED AND STAMPED BY A PROFESSIONAL ENGINEER LICENSED WITHIN THE STATE WHERE THE TOWER IS TO BE ERECTED. FOUNDATION DESIGN SHALL BE BASED ON FINAL APPROVED TOWER DESIGN ANO SOIL BORINGS DATA.
13. CONCRETE FOUNDATION SHALL BE FULLY 'FORMED' WITH APPROVED, CLEAN, STRUCTURALLY SOUND FORMS; BOTH ABOVE AND BELOW GRADE.
14. CONCRETE FOUNDATION SHALL BE ALLOWED TO CURE FOR A MINIMUM OF '7' DAYS PRIOR TO THE COMMENCEMENT OF TOWER ERECTION.
REFER TO SPECIFICATIONS FOR PROPER CURING CONDITIONS.
PLATFORM AND LADDER WORK:
1. ALL WORK SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS OF THE STANDARD BUILDING CODE, OCCUPATIONAL SAFETY
AND HEALTH REGULATIONS, AND LOCAL AUTHORITY HAVING JURISDICTION.
2. · DESIGN LIVE LOADS: UNIFORM LIVE LOAD 50 PSF, CONCENTRATED LIVE LOAD 500 LBS.
3. SHOP DRAWINGS FOR PLATFORMS, INCLUDING FRAMING MEMBERS, BEAMS COLUMNS, CONNECTIONS, ANCHORAGE, DECK MATERIALS, TREADS, PENETRATIONS, AND RAILING SHALL BE SUBMITTED TO THE ENGINEER AND A STAMPED APPROVAL RECEIVED BEFORE FABRICATION CAN PROCEED. ERECTIONS SHALL BE MADE FROM APPROVED SHOP DRAWINGS ONLY.
4. ALL WORK SHALL CONFORM TO THE DRAWINGS AND SPECIFICATIONS AND SHALL COMPLY WITH APPLICABLE CODES AND REGULATIONS, ALL CODES AND STANDARDS HEREIN REFERENCED SHALL BE LATEST EDITION, UNLESS OTHERWISE NOTED.
5. ALL SHOP CONNECTIONS THAT ARE TO BE WELDED SHALL BE ROUND SMOOTH. PLATFORMS SHALL BE SHIPPED TO THE SITE
IN THE LARGEST PRACTICAL PIECES TO MINIMIZE FJELD CONNECTIONS.
6. WELDED CONSTRUCTION SHALL COMPLY WITH AWS STRUCTURAL WELDING CODE 01.1 FOR PROCEDURE, APPEARANCE, AND
QUALITY OF WELDS AND WELDING METHODS, AND FOR CORRECTING WELDED WORK.
7. COORDINATE ALL PLATFORMS WITH CERTIFIED VENDOR EQUIPMENT DRAWINGS.
8. ALL HANDRAIL TUBING TO BE 1 1/2" DIA SCHEDULE 40 MINIMUM, AND SHALL HAVE Fy=41,000 PSI MINIMUM. ALL
VISIBLE WELDS TO BE GROUND SMOOTH.
FOR OFFICIAL USE ONLY
PUBLIC AVAILABILITY TO BE DETERMINED UNDER 5 USC 5 52
04/08/2016 CONSTRUCTION, WR •14659 1003172 0 6/24/2015
H
G
F
E
D
C
REV APPROVED
DATE DESCRIPTION JCN REDLINE
DATE Af'VD B
DEPARTMENT OF TRANSPORTATION
FEDERAL AVIATION ADMINISTRATION
ATO - TECHNICAL OPERATIONS EASTERN SERVICE AREA
BUEC
TOWER REPLACEMENT AND UPGRADES
GENERAL NOTES
BAKERSVILLE
REVIEWED BY SUBMITTED BY
J.TIMONY
PROJECT ENGINEER
DESIGNED ISSUED BY
1----f-----+�DR�AW=N------" J
-'-I T
ENGINEERING SERVICES
COMMUNICATIONS DG
CHECKED
JT
PA
APPROVED BY <:;;?"� �
M.GORDQN/
,,_ 7
MGR: ENGINEERING - CENTER C
DATE
04/08/2016 I
JCN
1003172
DRAWING NO REV
AR1-1003172-G003
z m m
(I) 0z 0 a 0
0 :e a
(I)
A� n
'cl
N n
;2
4 I DRAW!�!\ PP'}JUCfG t�A RO MiC.ROSiATi6H §Y;T[M
F
E
D
C
B
C
C C u ·c
,! A ro cO a,-� "' .---.'. S;I o-o-
N
\0 � oO oN .!- "' c, 0 ,n
Ii)
I 16" MIN
INSTALL 36 "W X 36 "H X 12 "D
JUNCTION BOX. SECURE TO TOWER
RAILING WITH STRUT (HOFFMAN
A36H3612GQRLP-WITH BACKING PLATE).
SECURE TWELVE 7/B" COAX CABLES TO
WAVEGUIDE LADDER EVERY 3' MINIMUM
USING SITE PRO 1 TRUE-GRIP HANGERS
(#78SH-3 ).
INSTALL 12, 7/8" COAX CABLES
(ANDREW P/N: AVA5-50FXl
FROM TOWER JUNCTION BOX GNO BAR
TO SHELTER SURGE PROTECTORS.
INSTALL 24" WIDE ICE BRIDGE KIT<Sl
WITH TRAPEZES, SITE PRO 1-IB24D-Z
WITH APPLICABLE SS TRUE-GRIP SNAP-IN
HANGERS (78SH-3) SIZED FOR DISTANCE
BETWEEN SHELTER AND TOWER. INSTALL
PER MANUFACTURER'S SPEC.
APPROX 45'
T
INSTALL 1" GRSC WITH 3, #12 THWN
FROM SHELTER AC PANEL TO PLATFORM
OB-LIGHT ATTACHED TO CABLE TRAPEZE.
pp
ICE BRIDGE SUPPORT POST,
EVERY 10 FEET MINIMUM, OR
LESS PER MANUFACTURERS
RECOMMENDATION
A SITE ELEVATION
C001 NOT TO SCALE
T
PROVIDE AND INSTALL
COAX CABLE WALL FEED
THROUGH PLATE WITH
FOUR. 4" HOLES;
ANDREW PIN: 204673-4
4, 4"-HOLE ENTRY BOOTS
FOR 7/8" HELIAX CABLE,
ANDREW P/N: SEC-378
PLUG EMPTY HOLES WITH
APPROVED PLUGS --�
EXACT HEIGHT AND LOCATION _J--------
TO BE DETERMINED IN FIELD,
SEAL ANY EMPTY OPENINGS
INSTALL #4/0 AWG INSULATED
CABLE (GREEN W/ RED TRACER)
CONNECTED TO SURGE PROT'N
GROUND PLATE WITH 2-HOLE
COMPRESSION LUG AND
EXOTHERMICALLY WELDED
TO COUNTERPOISE THROUGH
LB AND CONDUIT ON EXTERIOR
B
C001
CAD-WELD
NEW SCH 40 PVC
LB AND CONDUIT
FOR #4/0 GROUND CABLE
FROM INTERIOR JUNCTION
BOX GROUND BAR
EES COUNTERPOISE - EXISTING
2 1
H
G
F
E
BUEC SHELTER REAR ELEVATION
NOT TO SCALE
NOTES:
1 , 12, 7/8" HELIAX CABLES CAVA5-50FXl FROM THE SHELTER SURGE PROTECTORS
TO THE PLATFORM J-BOX GROUND BARS (APPROX 1600 LF TOTAL OF HELIAX
CABLE - FIELD VERIFY), CABLES ARE TERMINATED WITH N-MALE
CONNECTORS AT BOTH ENDS.
2, PROVIDE A WAVEGUIDE LADDER TO SUPPORT THE TWELVE 7/8" HELIAX CABLES,
VERTICALLY MOUNTED TO TOWER, THE WAVEGUIDE LADDER SHALL BE DESIGNED
WITH PREDRILLED HOLES, SPACED EVENLY, THE WAVEGUIDE SHALL BE DESIGNED
TO ACCEPT SITE PRO 1 "TRUE-GRIP SNAP-IN" HANGERS (#78SH-3) TO SECURE
THE HELIAX CABLES. THE WAVEGUIDE LADDER WILL SUPPORT THE HELIAX
CABLES AS THEY TRANSITION FROM THE HORIZONTAL CABLE ICE TRAY VERTICALLY
UP THE FULL TOWER HEIGHT TO THE JUNCTION BOX.
3, ALL UNDERGROUND GROUNDING CONDUCTOR CONNECTIONS ARE EXOTHERMICALLY
WELDED UNLESS OTHERWISE INDICATED.
4, WAVEGUIDE HORIZONTAL CABLE SUPPORTS SHALL BE SPACED AT 3 FEET INTERVALS
FOR THE FULL HEIGHT OF TOWER,
FOR OFFICIAL USE ONLY
PUBLIC AVAILABILITY TO BE DETERMINED UNDER 5 USC 552
04/08/2016 CONSTRUCTION, WR •14659 1003172 06/24/2015
D
C
REV APPROVED
DATE
DESCRIPTION JCN REDLINE
DATE APVD B
DEPARTMENT OF TRANSPORTATION
FEDERAL AVIATION ADMINISTRATION
ATO - TECHNICAL OPERATIONS EASTERN SERVICE AREA
BUEC
TOWER REPLACEMENT AND UPGRADES
COAX CABLE INSTALLATION DRAWING
BAKERSVILLE PA
REVIEWED BY APPROVED BY
PROJECT ENGINEER MGR: ENGINEERING - CENTER C
DESIGNED ISSUED BY D ATE
04/08/2016 JCN 1003172
t---+---1-D-R -AW_N ____ �
JT
ENGINEERING SERVICES r;;D.,,-RACCW"'IN G -":Nc'-'O ����---�=r.cR-EV t-----
-t-------J
�0�G COMMUNICATIONS
CHECKED
JT
AR1-1003172-C001
QC ro I- a,
(I) 0 ooz g
:e
A:
0 '
N g
C
� w
OR_AWING _ PROOl_!CEO ON _ _AJA RO_ MICRO§T A.TIQN SY5_!f.;M
| ar1-1003172-g001 |
| ar1-1003172-g002 |
| ar1-1003172-g003 |
| ar1-1003172-c001 |
| ar1-1003172-c002 |
| ar1-1003172-c003 |
| ar1-1003172-c004 |
| ar1-1003172-c005 |
| ar1-1003172-e001 |
| ar1-1003172-e002 |
| ar1-1003172-e003 |
| ar1-1003172-qfp001 |
File details come from the government source that posted it. Updated .