About this file

Amendment 0001 (pdf)

View the file

Other files

File Type Posted
Amendment 0002.pdf PDF
Pre-Proposal Site Visit.pdf PDF
Attachment 2-Wage Rates.pdf PDF
Amendment 0001.pdf PDF
Amendment 0003.pdf PDF
SIR DTFAEN-16-R-00130.pdf PDF
Attachment 4-Supplemental Offer Info.pdf PDF
Attachment 1a-Drawings.pdf PDF
Attachment 1 _Specifications.pdf PDF
Attachment 3-Business Declaration.pdf PDF
Pre-Proposal Site Visit.pdf PDF
SIR DTFAEN-16-R-00130.pdf PDF
Amendment 0001.pdf PDF
Attachment 3-Business Declaration.pdf PDF
Amendment 0002.pdf PDF
Attachment 1 _Specifications.pdf PDF
Attachment 1a-Drawings.pdf PDF
Attachment 4-Supplemental Offer Info.pdf PDF
Attachment 2-Wage Rates.pdf PDF
Attachment 1a-Drawings.pdf PDF
Attachment 1 _Specifications.pdf PDF
SIR DTFAEN-16-R-00130.pdf PDF
Attachment 2-Wage Rates.pdf PDF
Attachment 3-Business Declaration.pdf PDF
Amendment 0002.pdf PDF
Attachment 4-Supplemental Offer Info.pdf PDF
Amendment 0001.pdf PDF
Attachment 2-Wage Rates.pdf PDF
Attachment 1a-Drawings.pdf PDF
Attachment 4-Supplemental Offer Info.pdf PDF
Attachment 3-Business Declaration.pdf PDF
Attachment 1 _Specifications.pdf PDF
SIR DTFAEN-16-R-00130.pdf PDF
Attachment 1a-Drawings.pdf PDF
Attachment 4-Supplemental Offer Info.pdf PDF
Attachment 3-Business Declaration.pdf PDF
SIR DTFAEN-16-R-00130.pdf PDF
Attachment 2-Wage Rates.pdf PDF
Attachment 1 _Specifications.pdf PDF
Show all 39

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:

(a) By completing items 8 and 15, and returning or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE

PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment your desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

1. CONTRACT ID CODE

2. AMENDMENT/MODIFICATION NO. 3. EFFECTIVE DATE 5. PROJECT NO. (If applicable)

7. ADMINISTERED BY (If other than Item 6) CODE

STANDARD FORM 30 (REV. 10-83)

Prescribed by GSA FAR (48 CFR) 53.243

FACILITY CODE

10A. MODIFICATION OF CONTRACT/ORDER NO.

10B. DATED (SEE ITEM 13)

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

is not extended.

12. ACCOUNTING AND APPROPRIATION DATA (If required) copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;

13. THIS ITEM ONLY APPLIES TO MODIFICATION OF CONTRACTS/ORDERS.

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

CHECK ONE A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER NO.

IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority)

15C. DATE SIGNED

15A. NAME AND TITLE OF SIGNER (Type or print)

16C. DATE SIGNED

16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

PAGE OF PAGES

6. ISSUED BY CODE

8. NAME AND ADDRESS OF CONTRACTOR (No., street, county, State and ZIP Code) (X)

CODE

15B. CONTRACTOR/OFFEROR

(Signature of person authorized to sign)

16B. UNITED STATES OF AMERICA

(Signature of Contracting Officer)

NSN 7540-01-152-8070

Previous edition unusable

Linda Hennequant, Contracting Officer

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

Provide and Install Antenna Tower at the Back Up Emergency Communications (BUEC) Site, Bakersville, PA.

Amendment is issued to answer vendor questions. See attached.

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

Federal Aviation Administration Eastern Acquisitions Southern Region, AAQ-510 1701 Columbia Avenue College Park, GA 30337

Federal Aviation Administration Eastern Acquisitions Southern Region, AAQ-510 1701 Columbia Avenue College Park, GA 30337

4. REQUISITION/PURCHASE REQ. NO.

See Schedule

9A. AMENDMENT OF SOLICITATION

NO.

DTFAEN-16-R-00130

1 2

10/21/2016

9B. DATED (SEE ITEM 11)

10/11/2016

The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers is extended, X

AMENDMENT 0001

Solicitation DTFAEN-16-R-00130

Provide and Install Antenna Tower at the Back Up Emergency Communications (BUEC) Site, Bakersville, PA

THIS AMENDMENT IS BEING ISSUED TO INCORPORATE THE FOLLOWING

INFORMATION INTO THE REFERENCED SOLICITATION

QUESTIONS AND ANSWERS

1. QUESTION: The tower spec in this RFQ calls for a “222G”. The “222G” specifications are for a 90 MPH windload with up to .75 radial ice. Later in the RFQ, it calls for a 140 MPH rated tower with no ice, and 60 MPH with 1.25 inch ice. Which is a different tower all together. Please clarify.

FAA ANSWER: As called out in the project Specifications in Section 2.1.3: - “Unless otherwise indicated” EIA Standard TIA-222-G (Structural Standards for Steel Antenna Towers and Antenna Supporting Structures” shall govern….. in addition to being in accordance with AISC and AISI specifications and engineering practices.

Specification Section 2.1.4 – “Service Conditions” – within the Tower Design Criteria… we have stated that the tower design shall be analyzed based on wind speed inputs of: Basic wind speed = 140 mph with no ice (0” of radial ice), and also 60 mph wind speed (with 1.25” of radial ice) included….

Therefore, we have chosen to increase both the wind speeds and the radial ice thickness input during the design and analysis of this tower….. If this was not “otherwise indicated”, then the default would be the 90mph basic wind speed with no ice, and 40mph wind speed with 0.75” ice thickness as indicated from TIA would apply….

Other criteria to be used in the analysis, such as; Tower Classification, Exposure category and Topography category are also stated.

Tower Design Criteria TIA Standard RS-222-G 140 mph Basic wind speed (with 0” of radial ice) 60 mph wind speed (with 1.25” of radial ice) Class – III Exposure - C Topographic Category – 1 Location – Bakersville, PA

END OF AMENDMENT 0001