LAUNDRY

STORAGE

STAIR #2

2S2

LAUNDRY

TLT

JAN

OFFICE

BREEZEWAY

SLEEP

SLEEP

TLT

204A

SLEEP

SLEEP

SLEEP

SLEEP

TLT

208A

SLEEP

SLEEP

SLEEP

SLEEP

TLT

212A

SLEEP

SLEEP

SLEEP

SLEEP

TLT

216A

SLEEP

SLEEP

SLEEP

SLEEP

TLT

220A

SLEEP

SLEEP

SLEEP

SLEEP

TLT

205A

TLT

209A

TLT

213A

TLT

217A

TLT

221A

TLT

225A

MECHANICAL

248 SLEEP

SLEEP

TLT

224A

DRYER

251A

DRYER

251B

SLEEP

SLEEP

TLT

200A

SLEEP

SLEEP

TLT

201A

ED02

ED03

M A

T C

H L

IN

E

M A

T C

H L

IN

E

M A

T C

H L

IN

E

M A

T C

H L

IN

E

ED02

3 4 5 6 7 8 9 10

D

A

B

C

1 2

SLEEP

SLEEP

TLT

228A

SLEEP

SLEEP

SLEEP

SLEEP

TLT

232A

SLEEP

SLEEP

TLT

229A

TLT

233A

SLEEP

SLEEP

TLT

240A

SLEEP

SLEEP

TLT

241A

SLEEP

SLEEP

TLT

236A

SLEEP

SLEEP

TLT

237A

MECHANICAL

SLEEP

SLEEP

TLT

244A

SLEEP

SLEEP

TLT

245A

ED03

ED02

M A

T C

H L

IN

E

M A

T C

H L

IN

E

M A

T C

H L

IN

E

M A

T C

H L

IN

E 10 11 12 13 14

D

A

B

C

1. UNLESS OTHERWISE NOTED, REMOVE ALL EXISTING RECEPTACLES, LIGHTING FIXTURES,

SWITCHES AND ASSOCIATED COVER PLATES. EXISTING JUNCTION BOXES, CONDUIT AND WIRE

MAY BE REUSED FOR NEW DEVICES WHERE POSSIBLE.

2. REMOVE EXISTING ELECTRICAL DISTRIBUTION AS INDICATED ON SHEET ED601. EXISTING

CONDUIT AND WIRE MAY BE REUSED WHERE POSSIBLE.

3. IN CONNECTION WITH THE ALTERATIONS TO THE EXISTING BUILDING, THERE WILL BE

CERTAIN REMOVALS AND RELOCATIONS OF THE EXISTING ELECTRICAL WORK NECESSARY

FOR THE SATISFACTORY PERFORMANCE OF THE GENERAL WORK. CONTRACTOR SHALL VISIT

AND CAREFULLY EXAMINE THE EXISTING AREAS AFFECTED. IF DIFFICULTIES ARISE DURING

THE DEMOLITION WORK THAT ARE BEYOND THE CONTRACT DOCUMENTS AND REQUIRES

ADDITIONAL WORK, THE CONTRACTOR SHALL COORDINATE THIS WITH THE GOVERNMENT AND

RESOLVE THE ISSUE(S) PRIOR TO CONTINUING DEMOLITION OF THE AFFECTED AREA(S).

4. ALL ELECTRICAL ITEMS INSTALLED IN WALLS, FLOORS, OR CEILINGS THAT ARE TO BE

DEMOLISHED SHALL BE REMOVED IN THEIR ENTIRETY, UNLESS OTHERWISE NOTED OR

REQUIRED BY OTHER CONDITIONS IN THESE DOCUMENTS. THE CONTRACTOR SHALL CUT

BACK TO THE FLOOR, WALL OR CEILING AND PLUG BOTH ENDS OF CONCEALED CONDUITS

MADE OBSOLETE BY THIS ALTERATION. EXPOSED CONDUITS, WIREWAYS, PULL BOXES,

HANGERS, ETC., MADE OBSOLETE BY THE ALTERATION WORK SHALL BE REMOVED, UNLESS

OTHERWISE NOTED. ELECTRICAL CIRCUITS THAT ARE TO BE REMOVED SHALL BE REMOVED IN

THEIR ENTIRETY. CONDUCTORS SHALL BE COMPLETELY REMOVED FROM THE ITEM TO BE

DEMOLISHED BACK TO THE SOURCE OVERCURRENT DEVICE. EXISTING CONDUCTORS SHALL

NOT BE REUSED UNLESS OTHERWISE NOTED. SEE DRAWINGS OF ALL OTHER TRADES FOR

EXTENT OF DEMOLITION WORK. ELECTRICAL ITEMS SHALL INCLUDE POWER, LIGHTING,

COMMUNICATIONS AND SPECIAL SYSTEMS. REFER ALL QUESTIONS TO THE CONSTRUCTION

AND FACILITIES CONTRACTING OFFICE (CFMO) PRIOR TO BID FOR CLARIFICATION.

5. PHASING OF ELECTRICAL DEMOLITION SHALL FOLLOW THAT OF THE GENERAL

CONTRACTOR. COORDINATE REMOVAL OF ELECTRICAL WORK WITH OTHER CONSTRUCTION

ACTIVITIES AND THE REQUIREMENTS OF THE GOVERNMENT.

6. THERE ARE NO SPECIFIC ELECTRICAL ITEMS THAT THE GOVERNMENT WISHES TO

SALVAGE FOR THIS PROJECT. ALL REMOVED ELECTRICAL ITEMS THAT ARE PART OF THE

DEMOLITION WORK SHALL BECOME PROPERTY OF THE CONTRACTOR AND SHALL BE

REMOVED FROM THE SITE.

7. WHERE DEMOLITION WORK WILL INTERRUPT CIRCUIT CONTINUITY TO AREAS OF THE

FACILITY THAT ARE TO REMAIN IN OPERATION, PROVIDE RACEWAYS AND WIRING AS

APPROPRIATE TO MAINTAIN CIRCUITRY TO THESE AREAS. PROVIDE TEMPORARY

CONNECTIONS AS REQUIRED.

8. WHERE COMPLETION OF WORK WILL INTERFERE WITH THE NORMAL OPERATION OF THE

FACILITY, COORDINATION SHALL BE TAKEN TO COMPLETE THIS WORK DURING "OFF HOURS".

COORDINATE ANY ELECTRICAL SERVICE INTERRUPTIONS WITH THE GOVERNMENT AND THE

APPROPRIATE FACILITIES PERSONNEL 14 DAYS PRIOR TO COMMENCING WORK AND PROVIDE

PROVISIONS FOR TEMPORARY POWER AS REQUIRED UNTIL THE WORK IS COMPLETE. REFER

TO SPECIFICATION SECTION "01 14 00 WORK RESTRICTIONS" FOR FURTHER DETAILS AND

REQUIREMENTS FOR SUBMITTING A WRITTEN REQUEST FOR SERVICE INTERRUPTIONS.

9. FOR WORK DONE IN EXISTING AREAS OF THE FACILITY, ANY TASK OR ACTIVITY THAT WILL CREATE EXCESSIVE NOISE (ie. SAW CUTTING, CORE DRILLING, HAMMER VIBRATION DRILLING, ETC.) MAY NEED TO BE COMPLETED DURING "OFF HOURS". COORDINATE WITH THE

GOVERNMENT AND THE APPROPRIATE FACILITIES PERSONNEL, AT A MINIMUM, 14 DAYS PRIOR

TO COMMENCING WORK TO VERIFY IF IT NEEDS TO BE PERFORMED OFF HOURS.

10. WHERE EXISTING DEVICE OR JUNCTION BOXES MUST REMAIN IN EXISTING WALLS OR

CEILINGS (SUCH AS FOR CIRCUITS THAT MUST BE MAINTAINED TO SERVE OTHER AREAS),

THEN THEY SHALL BE FITTED WITH BLANK COVERPLATES.

11. WHERE DISTRIBUTION OR BRANCH CIRCUIT EQUIPMENT (PANELBOARDS, SWITCHBOARDS,

ETC.) IS TO BE REMOVED, THEN ALL FEEDERS OR BRANCH CIRCUITS WHICH SERVE ITEMS TO

REMAIN SHALL BE RECONNECTED TO NEW DISTRIBUTION OR BRANCH CIRCUIT EQUIPMENT AS

INDICATED. REFER ALL QUESTIONS TO THE CONTRACTING OFFICER'S REPRESENTATIVE (COR)

FOR ANY CLARIFICATION.

ELECTRICAL GENERAL NOTES FOR DEMOLITION:

12. COORDINATE WITH ELECTRICAL DEMOLITION PLANS AND VERIFY CIRCUITS TO BE

REMOVED WITH EXISTING FIELD CONDITIONS. ALL PANEL DIRECTORIES AFFECTED BY THIS

ALTERATION WORK SHALL BE MODIFIED TO REFLECT THE FINAL 'AS BUILT' CONDITIONS WITH

ROOM NUMBERS, ROOM NAME OR LOCATION OF WHERE EACH CIRCUIT IS LOCATED. PROVIDE

NEW PRINTED PANELBOARD DIRECTORIES FOR ALL NEW AND MODIFIED PANELBOARDS.

13. STOP WORK IMMEDIATELY AND CONTACT THE GOVERNMENT IF HAZARDOUS MATERIALS

(I.E. ASBESTOS, PCBs, ETC.), THAT ARE NOT SPECIFICALLY OUTLINED IN THE CONSTRUCTION

DOCUMENTS, ARE ENCOUNTERED AT ANY TIME.

14. DE-ENERGIZE ALL EXISTING ELECTRICAL EQUIPMENT PRIOR TO PERFORMING ANY

DEMOLITION WORK.

LOW VOLTAGE SYSTEM NOTES FOR DEMOLITION:

1. IN GENERAL, EXISTING TELEPHONE, CATV, AND PUBLIC ADDRESS SYSTEMS ARE EXISTING

TO REMAIN UNLESS NOTED OTHERWISE. THIS INCLUDES ALL OUTLETS, DEVICES AND

HORIZONTAL CABLING.

2. WIRELESS ACCESS SYSTEM TO BE REMOVED AND REINSTALLED BY OTHERS COORDINATE

WITH MCAS FEAD.

3. FIELD VERIFY IF ANY TELECOMMUNICATIONS MODIFICATIONS ARE REQUIRED.

4. THE CONTRACTOR TO TERMINATE AND TEST ANY NEW OR RELOCATED CABLING.

5. SERVICE ENTRANCE FOR TELECOMMUNICATIONS IS ON THE SECOND FLOOR MECHANICAL

ROOM 249. VERIFY AND MAINTAIN SERVICE.

6. DATA FIBER EXTENDS FROM ROOM 249 TO THE SECOND-FLOOR ELECTRICAL ROOM THAT

HAS A TELECOMMUNICATIONS WALL-MOUNTED CABINET. FROM THE SECOND-FLOOR

TELECOM CABINET, 4-PAIR, CAT 6 CABLES, DISTRIBUTE DATA THROUGHOUT THE BUILDING

USING OVERHEAD DISTRIBUTION. EXISTING DATA CABLING DISTRIBUTION SHALL BE

MAINTAINED.

7. VOICE PHONE SERVICE EXTENDS FROM ROOM 249 TO THE SECOND-FLOOR ELECTRICAL

ROOM AND THEN DISTRIBUTES THROUGHOUT THE BUILDING. THE SECOND AND THIRD

FLOOR’S VOICE SERVICE IS DISTRIBUTED OVERHEAD, AND THE FIRST FLOOR VOICE SERVICE

APPEARS TO BE DISTRIBUTED UNDERGROUND TO EACH OF THE SLEEPING ROOMS. VOICE

SERVICE WILL NEED TO BE RELOCATED FROM THE 1ST FLOOR ELECTRICAL ROOM WITH NEW,

MATCHING VOICE WIRING TO THE AFFECTED ROOMS.

8. CATV SERVICE ENTRANCE IS LOCATED ON THE 1ST FLOOR MECHANICAL ROOM 149.

DISTRIBUTION IS DONE THROUGH SIX CATV CABINETS, WITH 3 AT THE MECH ROOM 149 RISER

AND THEN EXTENDS TO 3 MORE CABINETS AT THE ELECTRICAL ROOM RISERS. CATV IS

DISTRIBUTED OVERHEAD TO EACH SLEEPING ROOM. THE CATV DISTRIBUTION AND CABINET

ON THE 1ST FLOOR ELECTRICAL ROOM SHALL BE RELOCATED WITH NEW CABLING TO THE

AFFECTED ROOMS.

N

TRUE

NORTH

IF SHEET MEASURES LESS THAN 22" X 34" IT IS A

REDUCED PRINT. REDUCE SCALE ACCORDINGLY

D

C

B

A

DES DRW CHK

SHEET OF

2 3 4 5

1 2 3 4 5

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D

C

B

A

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

APPROVED

FOR COMMANDER NAVFAC

ACTIVITY

SATISFACTORY TO DATE

A/E INFO

SEAL

AS NOTED

P L A N N I N G

A R C H I T E C T U R E

E N G I N E E R I N G

I N T E R I O R S

EST. 1915

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

/1

/2

:4

:0

A

M C

U s e rs

\k s h e n \D o c u m e n ts \A u to d e s k \R e v it

P ro je c ts

\B E

Q

-M

E P

F k s h e n

.r v t

100% CD - SEPTEMBER 2019

L A

D J o b N o -1

-0

ED102

E L E

C T

R

IC

A L D

E M

O L

IT

IO

N

P L A

N

S E

C O

N D

F L O

O R

R E

P A

IR

S

T O

B E

Q

10 Tenth Street N.E., Suite 200 Atlanta, GA 30309 Tel 404.874.8333 Fax 404.874.8330

6970752

C H

E R

R Y

P O

IN

T

N

C

12798579

N A

V F

A C

M

ID

-A T

L A

N T

IC

M a ri n e C o rp s A ir S ta ti o n

M C

A S

SMWSMW SCD

4'

SCALE : 1/8" = 1'-0"

0 8' 16'

SCALE: 1/8" = 1'-0"

C1

ELECTRICAL DEMOLITION PLAN - SECOND FLOOR - SE

SCALE: 1/8" = 1'-0"

A1

ELECTRICAL DEMOLITION PLAN - SECOND FLOOR - NW

KEYNOTE LEGEND

KEY DESCRIPTION

ED02 EXISTING ELECTRICAL PANELS TO BE DEMOLISHED

ED03 EXISTING TELEPHONE BACKBOARD TO REMAIN

SEAL

STORAGE

STAIR #2

3S2

LAUNDRY

TLT

ELEC

STORAGE

BREEZEWAY

LOUNGE

SLEEP

SLEEP

TLT

304A

SLEEP

SLEEP

SLEEP

SLEEP

TLT

308A

SLEEP

SLEEP

SLEEP

SLEEP

TLT

312A

SLEEP

SLEEP

SLEEP

SLEEP

TLT

316A

SLEEP

SLEEP

SLEEP

SLEEP

TLT

320A

SLEEP

SLEEP

SLEEP

SLEEP

TLT

305A

TLT

309A

TLT

313A

TLT

317A

TLT

321A

TLT

325A

MECHANICAL

348 SLEEP

SLEEP

TLT

324A

SLEEP

SLEEP

TLT

300A

SLEEP

SLEEP

TLT

301A

ED02

M A

T C

H L

IN

E

M A

T C

H L

IN

E

M A

T C

H L

IN

E

M A

T C

H L

IN

E

ED03

3 4 5 6 7 8 9 10

D

A

B

C

1 2

SLEEP

SLEEP

TLT

328A

SLEEP

SLEEP

SLEEP

SLEEP

TLT

332A

SLEEP

SLEEP

TLT

329A

TLT

333A

SLEEP

SLEEP

TLT

340A

SLEEP

SLEEP

TLT

341A

SLEEP

SLEEP

TLT

336A

SLEEP

SLEEP

TLT

337A

MECHANICAL

SLEEP

SLEEP

TLT

344A

SLEEP

SLEEP

TLT

345A

ED02

ED03

M A

T C

H L

IN

E

M A

T C

H L

IN

E

M A

T C

H L

IN

E

M A

T C

H L

IN

E

10 11 12 13 14

D

A

B

C

1. UNLESS OTHERWISE NOTED, REMOVE ALL EXISTING RECEPTACLES, LIGHTING FIXTURES,

SWITCHES AND ASSOCIATED COVER PLATES. EXISTING JUNCTION BOXES, CONDUIT AND WIRE

MAY BE REUSED FOR NEW DEVICES WHERE POSSIBLE.

2. REMOVE EXISTING ELECTRICAL DISTRIBUTION AS INDICATED ON SHEET ED601. EXISTING

CONDUIT AND WIRE MAY BE REUSED WHERE POSSIBLE.

3. IN CONNECTION WITH THE ALTERATIONS TO THE EXISTING BUILDING, THERE WILL BE

CERTAIN REMOVALS AND RELOCATIONS OF THE EXISTING ELECTRICAL WORK NECESSARY

FOR THE SATISFACTORY PERFORMANCE OF THE GENERAL WORK. CONTRACTOR SHALL VISIT

AND CAREFULLY EXAMINE THE EXISTING AREAS AFFECTED. IF DIFFICULTIES ARISE DURING

THE DEMOLITION WORK THAT ARE BEYOND THE CONTRACT DOCUMENTS AND REQUIRES

ADDITIONAL WORK, THE CONTRACTOR SHALL COORDINATE THIS WITH THE GOVERNMENT AND

RESOLVE THE ISSUE(S) PRIOR TO CONTINUING DEMOLITION OF THE AFFECTED AREA(S).

4. ALL ELECTRICAL ITEMS INSTALLED IN WALLS, FLOORS, OR CEILINGS THAT ARE TO BE

DEMOLISHED SHALL BE REMOVED IN THEIR ENTIRETY, UNLESS OTHERWISE NOTED OR

REQUIRED BY OTHER CONDITIONS IN THESE DOCUMENTS. THE CONTRACTOR SHALL CUT

BACK TO THE FLOOR, WALL OR CEILING AND PLUG BOTH ENDS OF CONCEALED CONDUITS

MADE OBSOLETE BY THIS ALTERATION. EXPOSED CONDUITS, WIREWAYS, PULL BOXES,

HANGERS, ETC., MADE OBSOLETE BY THE ALTERATION WORK SHALL BE REMOVED, UNLESS

OTHERWISE NOTED. ELECTRICAL CIRCUITS THAT ARE TO BE REMOVED SHALL BE REMOVED IN

THEIR ENTIRETY. CONDUCTORS SHALL BE COMPLETELY REMOVED FROM THE ITEM TO BE

DEMOLISHED BACK TO THE SOURCE OVERCURRENT DEVICE. EXISTING CONDUCTORS SHALL

NOT BE REUSED UNLESS OTHERWISE NOTED. SEE DRAWINGS OF ALL OTHER TRADES FOR

EXTENT OF DEMOLITION WORK. ELECTRICAL ITEMS SHALL INCLUDE POWER, LIGHTING,

COMMUNICATIONS AND SPECIAL SYSTEMS. REFER ALL QUESTIONS TO THE CONSTRUCTION

AND FACILITIES CONTRACTING OFFICE (CFMO) PRIOR TO BID FOR CLARIFICATION.

5. PHASING OF ELECTRICAL DEMOLITION SHALL FOLLOW THAT OF THE GENERAL

CONTRACTOR. COORDINATE REMOVAL OF ELECTRICAL WORK WITH OTHER CONSTRUCTION

ACTIVITIES AND THE REQUIREMENTS OF THE GOVERNMENT.

6. THERE ARE NO SPECIFIC ELECTRICAL ITEMS THAT THE GOVERNMENT WISHES TO

SALVAGE FOR THIS PROJECT. ALL REMOVED ELECTRICAL ITEMS THAT ARE PART OF THE

DEMOLITION WORK SHALL BECOME PROPERTY OF THE CONTRACTOR AND SHALL BE

REMOVED FROM THE SITE.

7. WHERE DEMOLITION WORK WILL INTERRUPT CIRCUIT CONTINUITY TO AREAS OF THE

FACILITY THAT ARE TO REMAIN IN OPERATION, PROVIDE RACEWAYS AND WIRING AS

APPROPRIATE TO MAINTAIN CIRCUITRY TO THESE AREAS. PROVIDE TEMPORARY

CONNECTIONS AS REQUIRED.

8. WHERE COMPLETION OF WORK WILL INTERFERE WITH THE NORMAL OPERATION OF THE

FACILITY, COORDINATION SHALL BE TAKEN TO COMPLETE THIS WORK DURING "OFF HOURS".

COORDINATE ANY ELECTRICAL SERVICE INTERRUPTIONS WITH THE GOVERNMENT AND THE

APPROPRIATE FACILITIES PERSONNEL 14 DAYS PRIOR TO COMMENCING WORK AND PROVIDE

PROVISIONS FOR TEMPORARY POWER AS REQUIRED UNTIL THE WORK IS COMPLETE. REFER

TO SPECIFICATION SECTION "01 14 00 WORK RESTRICTIONS" FOR FURTHER DETAILS AND

REQUIREMENTS FOR SUBMITTING A WRITTEN REQUEST FOR SERVICE INTERRUPTIONS.

9. FOR WORK DONE IN EXISTING AREAS OF THE FACILITY, ANY TASK OR ACTIVITY THAT WILL CREATE EXCESSIVE NOISE (ie. SAW CUTTING, CORE DRILLING, HAMMER VIBRATION DRILLING, ETC.) MAY NEED TO BE COMPLETED DURING "OFF HOURS". COORDINATE WITH THE

GOVERNMENT AND THE APPROPRIATE FACILITIES PERSONNEL, AT A MINIMUM, 14 DAYS PRIOR

TO COMMENCING WORK TO VERIFY IF IT NEEDS TO BE PERFORMED OFF HOURS.

10. WHERE EXISTING DEVICE OR JUNCTION BOXES MUST REMAIN IN EXISTING WALLS OR

CEILINGS (SUCH AS FOR CIRCUITS THAT MUST BE MAINTAINED TO SERVE OTHER AREAS),

THEN THEY SHALL BE FITTED WITH BLANK COVERPLATES.

11. WHERE DISTRIBUTION OR BRANCH CIRCUIT EQUIPMENT (PANELBOARDS, SWITCHBOARDS,

ETC.) IS TO BE REMOVED, THEN ALL FEEDERS OR BRANCH CIRCUITS WHICH SERVE ITEMS TO

REMAIN SHALL BE RECONNECTED TO NEW DISTRIBUTION OR BRANCH CIRCUIT EQUIPMENT AS

INDICATED. REFER ALL QUESTIONS TO THE CONTRACTING OFFICER'S REPRESENTATIVE (COR)

FOR ANY CLARIFICATION.

ELECTRICAL GENERAL NOTES FOR DEMOLITION:

12. COORDINATE WITH ELECTRICAL DEMOLITION PLANS AND VERIFY CIRCUITS TO BE

REMOVED WITH EXISTING FIELD CONDITIONS. ALL PANEL DIRECTORIES AFFECTED BY THIS

ALTERATION WORK SHALL BE MODIFIED TO REFLECT THE FINAL 'AS BUILT' CONDITIONS WITH

ROOM NUMBERS, ROOM NAME OR LOCATION OF WHERE EACH CIRCUIT IS LOCATED. PROVIDE

NEW PRINTED PANELBOARD DIRECTORIES FOR ALL NEW AND MODIFIED PANELBOARDS.

13. STOP WORK IMMEDIATELY AND CONTACT THE GOVERNMENT IF HAZARDOUS MATERIALS

(I.E. ASBESTOS, PCBs, ETC.), THAT ARE NOT SPECIFICALLY OUTLINED IN THE CONSTRUCTION

DOCUMENTS, ARE ENCOUNTERED AT ANY TIME.

14. DE-ENERGIZE ALL EXISTING ELECTRICAL EQUIPMENT PRIOR TO PERFORMING ANY

DEMOLITION WORK.

LOW VOLTAGE SYSTEM NOTES FOR DEMOLITION:

1. IN GENERAL, EXISTING TELEPHONE, CATV, AND PUBLIC ADDRESS SYSTEMS ARE EXISTING

TO REMAIN UNLESS NOTED OTHERWISE. THIS INCLUDES ALL OUTLETS, DEVICES AND

HORIZONTAL CABLING.

2. WIRELESS ACCESS SYSTEM TO BE REMOVED AND REINSTALLED BY OTHERS COORDINATE

WITH MCAS FEAD.

3. FIELD VERIFY IF ANY TELECOMMUNICATIONS MODIFICATIONS ARE REQUIRED.

4. THE CONTRACTOR TO TERMINATE AND TEST ANY NEW OR RELOCATED CABLING.

5. SERVICE ENTRANCE FOR TELECOMMUNICATIONS IS ON THE SECOND FLOOR MECHANICAL

ROOM 249. VERIFY AND MAINTAIN SERVICE.

6. DATA FIBER EXTENDS FROM ROOM 249 TO THE SECOND-FLOOR ELECTRICAL ROOM THAT

HAS A TELECOMMUNICATIONS WALL-MOUNTED CABINET. FROM THE SECOND-FLOOR

TELECOM CABINET, 4-PAIR, CAT 6 CABLES, DISTRIBUTE DATA THROUGHOUT THE BUILDING

USING OVERHEAD DISTRIBUTION. EXISTING DATA CABLING DISTRIBUTION SHALL BE

MAINTAINED.

7. VOICE PHONE SERVICE EXTENDS FROM ROOM 249 TO THE SECOND-FLOOR ELECTRICAL

ROOM AND THEN DISTRIBUTES THROUGHOUT THE BUILDING. THE SECOND AND THIRD

FLOOR’S VOICE SERVICE IS DISTRIBUTED OVERHEAD, AND THE FIRST FLOOR VOICE SERVICE

APPEARS TO BE DISTRIBUTED UNDERGROUND TO EACH OF THE SLEEPING ROOMS. VOICE

SERVICE WILL NEED TO BE RELOCATED FROM THE 1ST FLOOR ELECTRICAL ROOM WITH NEW,

MATCHING VOICE WIRING TO THE AFFECTED ROOMS.

8. CATV SERVICE ENTRANCE IS LOCATED ON THE 1ST FLOOR MECHANICAL ROOM 149.

DISTRIBUTION IS DONE THROUGH SIX CATV CABINETS, WITH 3 AT THE MECH ROOM 149 RISER

AND THEN EXTENDS TO 3 MORE CABINETS AT THE ELECTRICAL ROOM RISERS. CATV IS

DISTRIBUTED OVERHEAD TO EACH SLEEPING ROOM. THE CATV DISTRIBUTION AND CABINET

ON THE 1ST FLOOR ELECTRICAL ROOM SHALL BE RELOCATED WITH NEW CABLING TO THE

AFFECTED ROOMS.

N

TRUE

NORTH

IF SHEET MEASURES LESS THAN 22" X 34" IT IS A

REDUCED PRINT. REDUCE SCALE ACCORDINGLY

D

C

B

A

DES DRW CHK

SHEET OF

2 3 4 5

1 2 3 4 5

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D

C

B

A

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

APPROVED

FOR COMMANDER NAVFAC

ACTIVITY

SATISFACTORY TO DATE

A/E INFO

SEAL

AS NOTED

P L A N N I N G

A R C H I T E C T U R E

E N G I N E E R I N G

I N T E R I O R S

EST. 1915

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

/1

/2

:4

:1

A

M C

U s e rs

\k s h e n \D o c u m e n ts \A u to d e s k \R e v it

P ro je c ts

\B E

Q

-M

E P

F k s h e n

.r v t

100% CD - SEPTEMBER 2019

L A

D J o b N o -1

-0

ED103

E L E

C T

R

IC

A L D

E M

O L

IT

IO

N

P L A

N

T H

IR

D

F L O

O R

R E

P A

IR

S

T O

B E

Q

10 Tenth Street N.E., Suite 200 Atlanta, GA 30309 Tel 404.874.8333 Fax 404.874.8330

6970752

C H

E R

R Y

P O

IN

T

N

C

12798580

N A

V F

A C

M

ID

-A T

L A

N T

IC

M a ri n e C o rp s A ir S ta ti o n

M C

A S

SMWSMW SCD

4'

SCALE : 1/8" = 1'-0"

0 8' 16'

SCALE: 1/8" = 1'-0"

C1

ELECTRICAL DEMOLITION PLAN - THIRD FLOOR - SE

SCALE: 1/8" = 1'-0"

A1

ELECTRICAL DEMOLITION PLAN - THIRD FLOOR - NW

KEYNOTE LEGEND

KEY DESCRIPTION

ED02 EXISTING ELECTRICAL PANELS TO BE DEMOLISHED

ED03 EXISTING TELEPHONE BACKBOARD TO REMAIN

1ST FLOOR

2ND FLOOR

3RD FLOOR

LC

LE

LA

MDP

208/120V

800A

MCB

MA

MC

EXISTING TO

REMAIN 225 KVA

XFMR 12.47 KV -

208/120V

STREET LIGHTING

( EXISTING TO

REMAIN)

HEAT TRACE

( EXISTING TO REMAIN)

CHILLER ( EXISTING

TO REMAIN)

LF1

LB

LD

FIRE ALARM

PANEL

CPLP

TIME SWITCH

4-POLE

CONTACTOR

PRIMARY

LOOP FEED

DEMOLISH ALL

EXISTING

ELECTRICAL

DISTRIBUTION

REMOVE CONDUCTORS FROM EXISTING

DUCTBANK. THE DUCTBANK ALSO CONTAINS

TELECOMMUNICATIONS AND IS EXISTING TO

REMAIN.

M

METER

( EXISTING TO

REMAIN)

IF SHEET MEASURES LESS THAN 22" X 34" IT IS A

REDUCED PRINT. REDUCE SCALE ACCORDINGLY

D

C

B

A

DES DRW CHK

SHEET OF

2 3 4 5

1 2 3 4 5

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D

C

B

A

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

APPROVED

FOR COMMANDER NAVFAC

ACTIVITY

SATISFACTORY TO DATE

A/E INFO

SEAL

AS NOTED

P L A N N I N G

A R C H I T E C T U R E

E N G I N E E R I N G

I N T E R I O R S

EST. 1915

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

/1

/2

:4

:1

A

M C

U s e rs

\k s h e n \D o c u m e n ts \A u to d e s k \R e v it

P ro je c ts

\B E

Q

-M

E P

F k s h e n

.r v t

100% CD - SEPTEMBER 2019

L A

D J o b N o -1

-0

ED601

E L E

C T

R

IC

A L D

E M

O L

IT

IO

N

D

IA

G R

A M

R E

P A

IR

S

T O

B E

Q

10 Tenth Street N.E., Suite 200 Atlanta, GA 30309 Tel 404.874.8333 Fax 404.874.8330

6970752

C H

E R

R Y

P O

IN

T

N

C

12798581

N A

V F

A C

M

ID

-A T

L A

N T

IC

M a ri n e C o rp s A ir S ta ti o n

M C

A S

SMWSMW SCD

SCALE: NTS

A1

ELECTRICAL ONE-LINE DIAGRAM DEMOLITION

OS

OS

OS

M A

T C

H L

IN

E

M A

T C

H L

IN

E

M A

T C

H L

IN

E

M A

T C

H L

IN

E

F

F

F

FF

F

F

F FF FF FF FF

FF FF FF FF

F

F

F

FF

F

F

F FF FF FF

FF FF FF

F

F

F

F

F

F

F

F

BB B B B B

BB B B B

B

B

AAA A A A A A A A A A

A A

AAAAAAAA

A A

AA

II I I I II

H

H

G G G G G G G G

G G G G G G G G

G

G

G

G

GG

G

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

LC2- 10

EM

EM

EMEMEM

EM

I I I I

LA1- 10

I

X

EM

C1

C1

P

P

P

P

P

P

P

P P

P P P P

P P B

C1

EM

EM

B B

K

K

K

K

K

K

K

K

B B B

B

B B

LG- 16

LG- 14

X

B B

D

I

EM

EM

3 4 5 6 7 8 9 10

D

A

B

C

1 2

D D

J

M A

T C

H L

IN

E

M A

T C

H L

IN

E

M A

T C

H L

IN

E

M A

T C

H L

IN

E

FF

FF FF FF

FF FF

FF

FF

FF

FF FF FF

FF FF

FF

FF

F

F

F

F

F

F

F

F

B B B B

B B B B

B

B

A A A A A A A A

AAAAAAAA

A A

AA

3 3 3

I I I I I

H

H

G G G G G G

G G G G G G

G

G

G

G

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

LD2- 10

LB1LB1LB1LB1

LB2LB2LB2LB2

EM

I

I EM

I

EM

I

EM

EM

EM

LB1- 2

D

10 11 12 13 14

D

A

B

C

GENERAL LIGHTING NOTES

1. LIGHTING FIXTURE LOCATIONS IN SHAFTS AND MECHANICAL ROOMS ARE

APPROXIMATE. FIXTURE LOCATIONS MAY BE ADJUSTED IN FIELD TO

UTILIZE EXISTING RACEWAY OR TO COORDINATE WITH MEMCHANICAL

EQUIPMENT.

2. LIGHTING FIXTURES IN SLEEP ROOMS ARE CIRCUITED WITH

RECEPTACLES, SEE POWER PLANS.

3. CONNECT EMERGENCY BATTERY LIGHTING FIXTURES AND EXIT SIGNS TO

UNSWITCHED LEG OF THE CIRCUIT SERVING THAT AREA.

4. FOR COMPLETE LIGHTING FIXTURE SCHEDULE AND DETAILS REFER TO

SHEETS EL501 AND EL502.

N

TRUE

NORTH

IF SHEET MEASURES LESS THAN 22" X 34" IT IS A

REDUCED PRINT. REDUCE SCALE ACCORDINGLY

D

C

B

A

DES DRW CHK

SHEET OF

2 3 4 5

1 2 3 4 5

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D

C

B

A

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

APPROVED

FOR COMMANDER NAVFAC

ACTIVITY

SATISFACTORY TO DATE

A/E INFO

SEAL

AS NOTED

P L A N N I N G

A R C H I T E C T U R E

E N G I N E E R I N G

I N T E R I O R S

EST. 1915

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

/1

/2

:4

:1

A

M C

U s e rs

\k s h e n \D o c u m e n ts \A u to d e s k \R e v it

P ro je c ts

\B E

Q

-M

E P

F k s h e n

.r v t

100% CD - SEPTEMBER 2019

L A

D J o b N o -1

-0

EL101

E L E

C T

R

IC

A L L

IG

H

T

IN

G P

L A

N

F

IR

S T

F L O

O R

R E

P A

IR

S

T O

B E

Q

10 Tenth Street N.E., Suite 200 Atlanta, GA 30309 Tel 404.874.8333 Fax 404.874.8330

6970752

C H

E R

R Y

P O

IN

T

N

C

12798582

N A

V F

A C

M

ID

-A T

L A

N T

IC

M a ri n e C o rp s A ir S ta ti o n

M C

A S

SMWSMW SCD

4'

SCALE : 1/8" = 1'-0"

0 8' 16'

SCALE: 1/8" = 1'-0"

C1

ELECTRICAL LIGHTING PLAN - FIRST FLOOR - SE

SCALE: 1/8" = 1'-0"

A1

ELECTRICAL LIGHTING PLAN - FIRST FLOOR - NW

KEYNOTE LEGEND

KEY DESCRIPTION

EL01 OVERHEAD LIGHTING FIXTURES ARE CONNECTED TO RECEPTACLE

CIRCUITS, SEE POWER PLAN

EL02 SCONCE FIXTURE CIRCUITED TO RECEPTACLE CIRCUITS, SEE POWER

PLAN

OS

F

F

F

FF

F

F

F FF FF FF FF

FF FF FF FF

F

F

F

FF

F

F

F FF FF FF

FF FF FF

F

F

F

F

F

F

F

F

GG G G G G G

GG G G G G G

G

G

G

G

G

G

GG

AAA A A A A A A A A A

AAAAAAAAAA

A A

AA

BB B B B B

BB B B B

B

B

A

A

B

FF

FF

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

LC2- 12

33 3

II I I II I

LC2

LC1

H

H

LC1- 10

I

EM

I

EM

I

EM

I

EM EM I

EM

EM

EM

EM

I

J

B

B B

B B

B B

B B

B

B

B

B

EM

X

EM

B

B

H H

A

X

X

X

D

B

B

B

LC1- 18

LC1- 20

X

M A

T C

H L

IN

E

M A

T C

H L

IN

E

M A

T C

H L

IN

E

M A

T C

H L

IN

E

EM

3 4 5 6 7 8 9 10

D

A

B

C

1 2

FF

FF FF FF

FF FF

FF

FF

FF

FF FF FF

FF FF

FF

FF

F

F

F

F

F

F

F

F

G G G G G G

G G G G G G

G

G

G

G

A A A A A A A A

AAAAAAAA

A A

AA

B B B B

B B B B

B

B

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

3 3 3

I I I I I

LD2LD1

H

H

LD2- 12

EM EM

I

EM

IEMI

EM

EM

II

X

LD1- 8

M A

T C

H L

IN

E

M A

T C

H L

IN

E

M A

T C

H L

IN

E

M A

T C

H L

IN

E

10 11 12 13 14

D

A

B

C

GENERAL LIGHTING NOTES

1. LIGHTING FIXTURE LOCATIONS IN SHAFTS AND MECHANICAL ROOMS ARE

APPROXIMATE. FIXTURE LOCATIONS MAY BE ADJUSTED IN FIELD TO

UTILIZE EXISTING RACEWAY OR TO COORDINATE WITH MEMCHANICAL

EQUIPMENT.

2. LIGHTING FIXTURES IN SLEEP ROOMS ARE CIRCUITED WITH

RECEPTACLES, SEE POWER PLANS.

3. CONNECT EMERGENCY BATTERY LIGHTING FIXTURES AND EXIT SIGNS TO

UNSWITCHED LEG OF THE CIRCUIT SERVING THAT AREA.

4. FOR COMPLETE LIGHTING FIXTURE SCHEDULE AND DETAILS REFER TO

SHEETS EL501 AND EL502.

N

TRUE

NORTH

IF SHEET MEASURES LESS THAN 22" X 34" IT IS A

REDUCED PRINT. REDUCE SCALE ACCORDINGLY

D

C

B

A

DES DRW CHK

SHEET OF

2 3 4 5

1 2 3 4 5

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D

C

B

A

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

APPROVED

FOR COMMANDER NAVFAC

ACTIVITY

SATISFACTORY TO DATE

A/E INFO

SEAL

AS NOTED

P L A N N I N G

A R C H I T E C T U R E

E N G I N E E R I N G

I N T E R I O R S

EST. 1915

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

/1

/2

:4

:2

A

M C

U s e rs

\k s h e n \D o c u m e n ts \A u to d e s k \R e v it

P ro je c ts

\B E

Q

-M

E P

F k s h e n

.r v t

100% CD - SEPTEMBER 2019

L A

D J o b N o -1

-0

EL102

E L E

C T

R

IC

A L L

IG

H

T

IN

G P

L A

N

S E

C O

N D

F L O

O R

R E

P A

IR

S

T O

B E

Q

10 Tenth Street N.E., Suite 200 Atlanta, GA 30309 Tel 404.874.8333 Fax 404.874.8330

6970752

C H

E R

R Y

P O

IN

T

N

C

12798583

N A

V F

A C

M

ID

-A T

L A

N T

IC

M a ri n e C o rp s A ir S ta ti o n

M C

A S

SMWSMW SCD

4'

SCALE : 1/8" = 1'-0"

0 8' 16'

SCALE: 1/8" = 1'-0"

C1

ELECTRICAL LIGHTING PLAN - SECOND FLOOR - SE

SCALE: 1/8" = 1'-0"

A1

ELECTRICAL LIGHTING PLAN - SECOND FLOOR - NW

KEYNOTE LEGEND

KEY DESCRIPTION

EL01 OVERHEAD LIGHTING FIXTURES ARE CONNECTED TO RECEPTACLE

CIRCUITS, SEE POWER PLAN

EL02 SCONCE FIXTURE CIRCUITED TO RECEPTACLE CIRCUITS, SEE POWER

F

F

F

FF

F

F

F FF FF FF FF

FF FF FF FF

F

F

F

FF

F

F

F FF FF FF

FF FF FF

F

F

F

F

F

F

F

F

GG G G G G G

GG G G G G G

G

G

G

G

G

G

GG

G

AAA A A A A A A A A A

AAAAAAAAAA

A A

AA

BB B B B B

BB B B B

B

B

FF

FF

AA

B

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

III I I II

LE2

LE1

LC2- 14

LE1- 10

H

H

LE1- 10

EM EM EM EM

EM

EM

EM

EM

II

EM

P

P

P

P

P

P

P

P

P

P

P

P

J

B

B

B

B

B

EM

EM

A

LE1- 18

D

LE1- 20

X

X

X

X

X

B

B

B

M A

T C

H L

IN

E

M A

T C

H L

IN

E

M A

T C

H L

IN

E

M A

T C

H L

IN

E

EM

3 4 5 6 7 8 9 10

D

A

B

C

1 2

D

J

FF

FF FF FF

FF FF

FF

FF

FF

FF FF FF

FF FF

FF

FF

F

F

F

F

F

F

F

F

G G G G G G

G G G G G G

G

G

G

G

A A A A A A A A

AAAAAAAA

A A

AA

B B B B

B B B B

B

B

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

EL01

EL02

3 3 3

I I I I I

LD2- 14

LF2

LF1

H

H

LF1- 10

EM

EM EM

EM

EM

I III

EM X

M A

T C

H L

IN

E

M A

T C

H L

IN

E

M A

T C

H L

IN

E

M A

T C

H L

IN

E

10 11 12 13 14

D

A

B

C

GENERAL LIGHTING NOTES

1. LIGHTING FIXTURE LOCATIONS IN SHAFTS AND MECHANICAL ROOMS ARE

APPROXIMATE. FIXTURE LOCATIONS MAY BE ADJUSTED IN FIELD TO

UTILIZE EXISTING RACEWAY OR TO COORDINATE WITH MEMCHANICAL

EQUIPMENT.

2. LIGHTING FIXTURES IN SLEEP ROOMS ARE CIRCUITED WITH

RECEPTACLES, SEE POWER PLANS.

3. CONNECT EMERGENCY BATTERY LIGHTING FIXTURES AND EXIT SIGNS TO

UNSWITCHED LEG OF THE CIRCUIT SERVING THAT AREA.

4. FOR COMPLETE LIGHTING FIXTURE SCHEDULE AND DETAILS REFER TO

SHEETS EL501 AND EL502.

N

TRUE

NORTH

IF SHEET MEASURES LESS THAN 22" X 34" IT IS A

REDUCED PRINT. REDUCE SCALE ACCORDINGLY

D

C

B

A

DES DRW CHK

SHEET OF

2 3 4 5

1 2 3 4 5

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D

C

B

A

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

APPROVED

FOR COMMANDER NAVFAC

ACTIVITY

SATISFACTORY TO DATE

A/E INFO

SEAL

AS NOTED

P L A N N I N G

A R C H I T E C T U R E

E N G I N E E R I N G

I N T E R I O R S

EST. 1915

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

/1

/2

:4

:2

A

M C

U s e rs

\k s h e n \D o c u m e n ts \A u to d e s k \R e v it

P ro je c ts

\B E

Q

-M

E P

F k s h e n

.r v t

100% CD - SEPTEMBER 2019

L A

D J o b N o -1

-0

EL103

E L E

C T

R

IC

A L L

IG

H

T

IN

G P

L A

N

T H

IR

D

F L O

O R

R E

P A

IR

S

T O

B E

Q

10 Tenth Street N.E., Suite 200 Atlanta, GA 30309 Tel 404.874.8333 Fax 404.874.8330

6970752

C H

E R

R Y

P O

IN

T

N

C

12798584

N A

V F

A C

M

ID

-A T

L A

N T

IC

M a ri n e C o rp s A ir S ta ti o n

M C

A S

SMWSMW SCD

4'

SCALE : 1/8" = 1'-0"

0 8' 16'

SCALE: 1/8" = 1'-0"

C1

ELECTRICAL LIGHTING PLAN - THIRD FLOOR - SE

SCALE: 1/8" = 1'-0"

A1

ELECTRICAL LIGHTING PLAN - THIRD FLOOR - NW

KEYNOTE LEGEND

KEY DESCRIPTION

EL01 OVERHEAD LIGHTING FIXTURES ARE CONNECTED TO RECEPTACLE

CIRCUITS, SEE POWER PLAN

EL02 SCONCE FIXTURE CIRCUITED TO RECEPTACLE CIRCUITS, SEE POWER

D D D D D D

LF1- 8

D D

M A

T C

H L

IN

E

M A

T C

H L

IN

E

M A

T C

H L

IN

E

M A

T C

H L

IN

E

10 11 12 13 14

D

A

B

C

D D D D D D D D D D D

LE1- 8

LOCATE SWITCH NEAR HATCH

ENTRY TO ATTIC

DD

M A

T C

H L

IN

E

M A

T C

H L

IN

E

M A

T C

H L

IN

E

M A

T C

H L

IN

E

3 4 5 6 7 8 9 10

D

A

B

C

1 2

IF SHEET MEASURES LESS THAN 22" X 34" IT IS A

REDUCED PRINT. REDUCE SCALE ACCORDINGLY

D

C

B

A

DES DRW CHK

SHEET OF

2 3 4 5

1 2 3 4 5

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D

C

B

A

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

APPROVED

FOR COMMANDER NAVFAC

ACTIVITY

SATISFACTORY TO DATE

A/E INFO

SEAL

AS NOTED

P L A N N I N G

A R C H I T E C T U R E

E N G I N E E R I N G

I N T E R I O R S

EST. 1915

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

/1

/2

:4

:3

A

M C

U s e rs

\k s h e n \D o c u m e n ts \A u to d e s k \R e v it

P ro je c ts

\B E

Q

-M

E P

F k s h e n

.r v t

100% CD - SEPTEMBER 2019

L A

D J o b N o -1

-0

EL104

E L E

C T

R

IC

A L L

IG

H

T

IN

G P

L A

N

A T

T

IC

R E

P A

IR

S

T O

B E

Q

10 Tenth Street N.E., Suite 200 Atlanta, GA 30309 Tel 404.874.8333 Fax 404.874.8330

6970752

C H

E R

R Y

P O

IN

T

N

C

12798585

N A

V F

A C

M

ID

-A T

L A

N T

IC

M a ri n e C o rp s A ir S ta ti o n

M C

A S

SMWSMW SCD

SCALE: 1/8" = 1'-0"

A1

ELECTRICAL ATTIC PLAN - NW

SCALE: 1/8" = 1'-0"

C1

ELECTRICAL ATTIC PLAN - SE

1.

2.

3.

4.

5.

PROVIDE COMPLETE CONDUCTOR AND CONDUIT CONNECTIONS AS

REQUIRED. LIGHTING SENSOR CONTROLS BASIS OF DESIGN IS A

24VDC AND POWER PACK SYSTEM OR APPROVED EQUAL. CONTROL

DIAGRAM REPRESENTS A POSSIBLE CONFIGURATION THAT MAY

MEET THE DESIGN INTENT. IS NOT MEANT TO INDICATE A CERTAIN

MANUFACTURER OR PREFERENCE. ACTUAL SOLUTION MAY VARY

AND CONTAIN ADDITIONAL OR LESS DEVICES WITH A DIFFERENT

CONFIGURATION.

PROVIDE SENSORS AS INDICATED ON THE PLANS AND CONFIRM

WITH MANUFACTURER MAXIMUM NUMBER OF SENSORS ALLOWED

PER POWER PACK. COORDINATE SENSOR CONNECTIONS WITH

SINGLE-POLE, THREE-WAY OR DIMMING SWITCHES AS INDICATED ON

FLOOR PLANS. INSTALL POWER PACKS TO CONTROL ONLY THAT

PORTION OF THE CIRCUIT SERVING THE LIGHTING IN THE ROOM OR

AREA SERVED. LINE-VOLTAGE TO POWER PACKS ARE TO BE

CONNECTED AHEAD OF ANY WALL SWITCHES. PROVIDE SHOP

DRAWINGS INDICATING POWER PACK LOCATIONS ON PLANS.

ON/OFF OCCUPANCY SENSORS SHALL BE CEILING MOUNTED OR

WALL MOUNTED SWITCH AS INDICATED ON PLANS. SET OCCUPANCY

"OFF-DELAY" TO 20 MINUTES FOR ALL AREAS, UON. IN AREAS WHERE

DAYLIGHTING CONTROLS ARE INDICATED, PROVIDE SINGLE-ZONE

ON/OFF AND DIMMING CLOSED LOOP PHOTOSENSORS AS REQUIRED.

CONTRACTOR SHALL COORDINATE A PRE-CONSTRUCTION MEETING

WITH THE LIGHTING CONTROLS REPRESENTATIVE TO VERIFY

SYSTEM INSTALLATION REQUIREMENTS AND ALSO SCHEDULE FOR A

MANUFACTURER TECHNICIAN TO COMMISSION THE LIGHTING

CONTROL SYSTEM AND PROVIDE ANY INITIAL SETTINGS OF THE

SYSTEM AS REQUIRED. THE TECHNICIAN SHALL ALSO PROVIDE A

MINIMUM OF 1 DAY OF TRAINING SESSIONS FOR THE BUILDING

MANAGEMENT STAFF TO COVER INSTALLATION, SETTINGS,

OPERATION AND TROUBLE-SHOOTING. TRAINING SHALL OCCUR AT A

CONVENIENT TIME WITHIN 30 DAYS AFTER BUILDING OCCUPANCY.

SENSOR TYPE LIGHTING CONTROL SYSTEMS MUST SHOW THE

ABILITY TO PROVIDE CONTROLS AS PER THE DESIGN INTENT THAT

INCLUDES BUT IS NOT LIMITED TO: USE OF 24VDC TYPE SENSORS

AND THE ABILITY TO COMMUNICATE WITH LUMINAIRE BALLASTS

AND/OR DRIVERS AS REQUIRED. THE CONTRACTOR SHALL PROVIDE

A FULLY FUNCTIONAL SYSTEM AND COMPLETE ENGINEERED SHOP

DRAWINGS.

+24VDC

CONTROL OUTPUT

COMMON

+24VDC

CONTROL OUTPUT

COMMON

NEUTRAL

HOT

R E

D

BLK

B

LK

B

LU

WHT

POWER

PACK

RED

RED

ANY 24VDC

CEILING OR

WALL

SENSOR

3#18 AWG-1/2"C.

24VDC SENSOR TYPE LIGHTING CONTROL SYSTEM NOTES:

ANY 24VDC

CEILING OR

WALL

SENSOR

LIGHTS OFF

LIGHTS ON IF OCCUPIED

LIGHTS OFF AFTER TIME DELAY

IF UNOCCUPIED.

SWITCH OFF

SWITCH ON

LOCAL

OFF

SWITCH

LOAD

LOCAL OFF SWITCH OPERATION:

HOT

NEUTRAL

OFF

HAND AUTO

ILLUMINATED HAND-OFF-AUTO (H-O-A) SELECTOR SWITCH: 3 POSITION

MAINTAINED CONTACT / MANUAL RETURN, 120VAC TRANSFORMER TYPE RED LED

LAMP, RED KNOB, "HAND-OFF-AUTO" LEGEND, FLUSH STAINLESS STEEL NEMA 1

COVER PLATE WITH LABEL THAT READS "OUTDOOR LIGHTS".

2-CHANNEL - MAINTAINED, ASTRONOMIC, DIGITAL TIME SWITCH WITH

40A GENERAL PURPOSE CONTACTS, 20 SET POINTS, AUTOMATIC

DAYLIGHT SAVINGS TIME, LEAP YEAR COMPENSATION, LCD DISPLAY,

PERMANENT SCHEDULE RETENTION, 4-DAYS OF REAL TIME BACKUP,

LOAD STATUS AND POWER FAILURE INDICATION.

20A, 1P, 120V

CIRCUIT.

R C

CH1TC

LIGHTING CONTACTOR (LC-1): 30A, 120VAC OR

277VAC AS NOTED, 6-POLE, N.O. CONTACTS, 120VAC

COIL, ELECTRICALLY HELD, NEMA 1 ENCLOSURE.

CH2

IF SHEET MEASURES LESS THAN 22" X 34" IT IS A

REDUCED PRINT. REDUCE SCALE ACCORDINGLY

D

C

B

A

DES DRW CHK

SHEET OF

2 3 4 5

1 2 3 4 5

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D

C

B

A

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

APPROVED

FOR COMMANDER NAVFAC

ACTIVITY

SATISFACTORY TO DATE

A/E INFO

SEAL

AS NOTED

P L A N N I N G

A R C H I T E C T U R E

E N G I N E E R I N G

I N T E R I O R S

EST. 1915

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

/1

/2

:4

:3

A

M C

U s e rs

\k s h e n \D o c u m e n ts \A u to d e s k \R e v it

P ro je c ts

\B E

Q

-M

E P

F k s h e n

.r v t

100% CD - SEPTEMBER 2019

L A

D J o b N o -1

-0

EL501

L

IG

H T

IN

G

F

IX

T U

R E

S C

H E

D U

L E

A N

D D

E T

A

IL

S

R E

P A

IR

S

T O

B E

Q

10 Tenth Street N.E., Suite 200 Atlanta, GA 30309 Tel 404.874.8333 Fax 404.874.8330

6970752

C H

E R

R Y

P O

IN

T

N

C

12798586

N A

V F

A C

M

ID

-A T

L A

N T

IC

M a ri n e C o rp s A ir S ta ti o n

M C

A S

SMWSMW SCD

LIGHTING FIXTURE SCHEDULE

FIXTURE

TYPE DESCRIPTION

LAMP

APPARENT

LOAD

VOLTAGE MOUNTING COMMENTS

NO. OF

LAMPS WATTS TYPE CCT

INPUT

POWER

A 3 FOOT VANITY LUMINAIRE. 1 15 W LED 1500

LUMENS

3500 K 15 VA 120 V WALL MOUNTED MOUNT FIXTURE 6'-8" AFF,

UON.NL-9

B 1x4 SURFACE TROFFER LUMINAIRE. 1 19 W LED - 2,000

LUMENS

3500 K 19 VA 120 V SURFACE NL-5, FIXTURE MUST BE

LESS THAN 3" DEEP

C1 LED 2x2 LENSED TROFFER WITH

0.125 ACRYLIC LENS. 0-10V

DIMMING DRIVER, PAINTED AFTER

FABRICATION.

1 26 W LED - 3000

DESIGN

LUMENS

3500 K 26 VA 120 V RECESSED NL-3

D 4 FEET LONG, LED INDUSTRIAL

STRIP WITH REFLECTOR. PAINTED

AFTER FABRICATION.

1 24 W LED - 2500

LUMENS

3500 K 24 VA 120 V SURFACE SUSPEND USING CHAIN IN

AREAS WITHOUT CEILING

AT 7'-0" AFF. NL-7

EM WET LOCATION EMERGENCY

LIGHTING UNIT WITH ADJUSTABLE

LAMP HEADS.

2 2 W LED - 80

LUMENS

3500 K 4 VA 120 V SURFACE MOUNT FIXTURE 7'-6" AFF,

UON. NL-67

F 2x2 SURFACE TROFFER LUMINAIRE. 1 30 W LED - 3,300

LUMENS

3500 K 30 VA 120 V SURFACE NL-5

G EXISTING EXTERIOR WALL SCONCE. 1 11 W LED - 560

LUMENS

3500 K 11 VA 120 V WALL MOUNTED EXISTING TO REMAIN

H 4 FEET LONG, LED INDUSTRIAL

STRIP WITH REFLECTOR. PAINTED

AFTER FABRICATION. MOUNT AT

8'-0" AFF UON.

1 48 W LED - 5,200

DESIGN

LUMENS

3500 K 48 VA 120 V SURFACE NL-7

I WALL MOUNTED LED VAPORTIGHT

FIXTURE

1 15 W LED - 560

LUMENS

3500 K WALL NL-1

J 4 FOOT COMMERCIAL WALL

BRACKET. 180 DEGREE LENS

1 30 W LED - 3,000

LUMENS

3500 K 30 VA 120 V WALL MOUNTED MOUNT FIXTURE 7'-0" AFF,

UON. NL-9

K FLEXIBLE SURFACE MOUNTED LED

STRIP

1 7 W LED - 700

LUMENS

3500 K 7 VA 120 V SURFACE COVE NL-2

P PENDANT ROUND LUMINAIRE. 1 15 W LED 1000

LUMENS

3500 K 15 VA 120 V PENDANT MOUNT FIXTURE 8'-0" AFF

TO THE BOTTOM,

UON.NL-15

X LED EXIT SIGN. GREEN LETTERING.

CAST ALUMINUM HOUSING, NEMA

4X

1 1 W LED (SIGN) 3500 K 1 VA 120 V CEILING, PENDANT OR

WALL AS SHOWN

PROVIDE NUMBER OF

FACES AND CHEVRONS AS

SHOWN ON PLANS. NL-63

REVISED: NL-1LIGHTING PLATE:

VAPORTIGHT FIXTURE

CONSTRUCTION - CAST-ALUMINUM HOUSING WITH CORROSION-RESISTANT PAINT IN AN INDUSTRIAL

GREY FINISH. SEALED GASKET PROTECTS AGAINST MOISTURE AND DUST.

OPTICS - 3500K CCT LEDS. FROSTED GLASS DIFFUSER PROVIDES EVEN LIGHT DISTRIBUTION.

LUMEN MAINTENANCE - LEDS WILL DELIVER 70% OF THEIR INITIAL LUMENS AT 50,000 HOUR AVERAGE

LED LIFE.

ELECTRICAL – DRIVER OPERATES ON ANY LINE VOLTAGE FROM 120-277V, OPERATING

TEMPERATURE -40ºC TO 40ºC. 4KV SURGE PROTECTION STANDARD.

INSTALLATION - MOUNTS TO CEILING OR WALL WITH SURFACE MOUNT JUNCTION BOX (INCLUDED).

LISTINGS - UL LISTED TO U.S. AND CANADIAN SAFETY STANDARDS FOR WET LOCATIONS. TESTED IN

ACCORDANCE WITH IESNA LM-79 AND LM-80 STANDARDS.

THIS SKETCH IS A NON-PROPRIETARY GRAPHIC REPRESENTATION OF A LUMINAIRE THAT MAY MEET THE SPECIFICATION REQUIREMENTS. IT IS NOT INTENDED TO INDICATE A CERTAIN MANUFACTURER

OR PREFERENCE.

LUMINAIRE REQUIREMENTS:

1.

2.

3.

4.

5.

REVISED: NL-2LIGHTING PLATE:

FLEXIBLE STRIP FIXTURE

LIGHTING FIXTURES SHALL BE PROVIDED AS SPECIFIED IN THE SCHEDULE AND THE LIGHTING FIXTURE DETAILS OR APPROVED EQUIVALENT. LIGHTING FIXTURES

INDICATED ARE A BASIS OF DESIGN AND THERE IS NO INTENT TO SOLE SOURCE.

PROVIDE ALL FIXTURES COMPLETE WITH ALL ACCESSORIES TO MEET THE DESCRIPTION AND FUNCTIONAL REQUIREMENTS. PROPOSED LUMINAIRES MUST SHOW TO BE EQUIVALENT OR BETTER IN, BUT NOT LIMITED TO, THE FOLLOWING: PHOTOMETRIC CHARACTERISTIC, MATERIALS, CONSTRUCTION, FEATURES, FINISHES, LENSES, ENERGY CONSUMPTION, ETC. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL REQUIRED CIRCUITRY, DEVICES, AND CONTROLS WIRING.

PROVIDE HANGER WIRE SUPPORT FROM BUILDING STRUCTURE TO EACH CORNER OF LIGHT FIXTURES FOR ALL RECESSED CEILING TYPE FIXTURES. COORDINATE WITH CEILING CONSTRUCTION TYPE FOR FIXTURE SUPPORT. PROVIDE ALL HARDWARE, FRAME-IN KITS, ETC. AS REQUIRED FOR COMPLETE INSTALLATION.

PROVIDE LAMPS MEETING THE MINIMUM REQUIREMENTS AS SPECIFIED FOR ALL FIXTURES. ALL LAMPS SHALL BE NEW. ALL LAMPS OF THE SAME TYPE SHALL BE BY THE

SAME MANUFACTURER TO MATCH PROPERTIES.

WHERE DIMMING BALLASTS AND/OR SWITCHES ARE INDICATED ON THE PLANS, THE CONTRACTOR SHALL VERIFY AND PROVIDE COMPATIBLE EQUIPMENT THAT FUNCTIONS

AS INTENDED. DIMMED LIGHT FIXTURES MUST NOT FLICKER OR HUM.

PROVIDE APPROPRIATE FLANGE TRIM OR LAY-IN GRID ACCESSORIES FOR RECESSED FIXTURES AS REQUIRED PER THE CEILING TYPES SHOWN ON THE DRAWINGS.

ALL LED FIXTURES SHALL HAVE A 10-YEAR WARRANTY. REFER TO SPECIFICATIONS.

LIGHTING FIXTURE SCHEDULE NOTES

1.

2.

3.

4.

5.

6.

7.

DESCRIPTION - FLEXIBLE LED STRIP LIGHT WITH ADHESIVE BACKING AND ALUMINUM MOUNTING

CHANNEL. CAN BE CUT EVERY 2".

OPTICS - 3500K CCT LEDS. 18 LEDS PER FOOT.

ELECTRICAL – 12VDC DRIVER. 116 LUMENS PER FOOT.DIMMABLE.

INSTALLATION - SURFACE MOUNTED.

LISTINGS - UL LISTED FOR DAMP LOCATIONS. IP65 RATED.

THIS SKETCH IS A NON-PROPRIETARY GRAPHIC REPRESENTATION OF A LUMINAIRE THAT MAY MEET THE SPECIFICATION REQUIREMENTS. IT IS NOT INTENDED TO INDICATE A CERTAIN MANUFACTURER

OR PREFERENCE.

LUMINAIRE REQUIREMENTS:

1.

2.

3.

4.

5.

6.

SCALE: NTS

A1

LTG - TYPICAL CONTROLS WIRING - 24 VDC

SCALE: NTS

A3

EXTERIOR LIGHTING CONTROL

IF SHEET MEASURES LESS THAN 22" X 34" IT IS A

REDUCED PRINT. REDUCE SCALE ACCORDINGLY

D

C

B

A

DES DRW CHK

SHEET OF

2 3 4 5

1 2 3 4 5

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D

C

B

A

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

APPROVED

FOR COMMANDER NAVFAC

ACTIVITY

SATISFACTORY TO DATE

A/E INFO

SEAL

AS NOTED

P L A N N I N G

A R C H I T E C T U R E

E N G I N E E R I N G

I N T E R I O R S

EST. 1915

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

/1

/2

:4

:3

A

M C

U s e rs

\k s h e n \D o c u m e n ts \A u to d e s k \R e v it

P ro je c ts

\B E

Q

-M

E P

F k s h e n

.r v t

100% CD - SEPTEMBER 2019

L A

D J o b N o -1

-0

EL502

L

IG

H T

IN

G

D E

T A

IL

S

R E

P A

IR

S

T O

B E

Q

10 Tenth Street N.E., Suite 200 Atlanta, GA 30309 Tel 404.874.8333 Fax 404.874.8330

6970752

C H

E R

R Y

P O

IN

T

N

C

12798587

N A

V F

A C

M

ID

-A T

L A

N T

IC

M a ri n e C o rp s A ir S ta ti o n

M C

A S

SMWSMW SCD

PRISMATIC LENS LED TROFFER

REVISED: APRIL 2016 NL-3LIGHTING PLATE:

LUMINAIRE REQUIREMENTS:

1. HOUSING - DIE-FORMED, COLD ROLLED STEEL, PAINTED AFTER FABRICATION. EXTRUDED

ALUMINUM DOOR WITH SPRING-LOADED CAM LATCHES. HIGH REFLECTANCE, WHITE POLYESTER

POWDER-COATED FINISH. OPTIONAL SIZES OF 1FT x 4FT, 2FT x 2FT, AND 2FT x 4FT AVAILABLE.

2. LIGHT SOURCE - LED BOARD OR ARRAY WITH MINIMUM 50K HOURS RATED LIFE AT L70, 3500K

COLOR TEMPERATURE UON, MAXIMUM 4-STEP MCADAM ELLIPSE BINNING TOLERANCE FOR COLOR

CONSISTENCY, MINIMUM EFFICACY OF 90 LUMENS/WATT, WITH A MINIMUM CRI OF 80. INITIAL

LUMEN OUTPUT AS INDICATED IN LUMINAIRE SCHEDULE.

4. DRIVER - REPLACEABLE, INTEGRAL, HIGH-EFFICIENCY DRIVER WITH MINIMUM 0.9 PF, OPERATING

VOLTAGE OF 120-277V, THERMAL MANAGEMENT, < 20% TOTAL HARMONIC DISTORTION.

STEP-DIMMABLE OR FULLY DIMMABLE AS INDICATED IN LUMINAIRE SCHEDULE.

5. CERTIFICATION - UL 1598, DAMP LOCATION, DLC QUALIFIED, AND ROHS COMPLIANT. COMPLIES

WITH LM79, LM80 AND TM21 TESTING STANDARDS. UL 924 WHEN EQUIPPED WITH EMERGENCY

BATTERY BACK-UP. IC RATED WHEN INDICATED.

6. MOUNTING - RECESSED IN SUSPENDED ACOUSTICAL TILE OR HARD CEILING.

7. THIS SKETCH IS A NON-PROPRIETARY GRAPHIC REPRESENTATION OF A LUMINAIRE THAT MAY MEET

THE SPECIFICATION REQUIREMENTS. IT IS NOT INTENDED TO INDICATE A CERTAIN MANUFACTURER

OR PREFERENCE.

LED INDUSTRIAL STRIP

REVISED: APRIL 2016 NL-7LIGHTING PLATE:

LUMINAIRE REQUIREMENTS:

1. HOUSING - DIE-FORMED, COLD-ROLLED STEEL, WITH REINFORCEMENT RIBS FOR RIGIDITY AND

SPECULAR ALUMINUM OR HIGHLY-REFLECTIVE PAINTED STEEL REFLECTORS. OPTIONAL LENGTHS

OF 4FT OR 8FT.

2. FINISH - MULTI-STAGE PHOSPHATE BONDING TREATMENT FINISHED WITH HIGH-REFLECTANCE, WHITE POLYESTER POWDER COAT, PAINTED AFTER FABRICATION.

3. LIGHT SOURCE - SOLID STATE LEDS WITH MINIMUM 50K HOURS RATED LIFE AT L70, 3500K CCT UON, MINIMUM 80 CRI, MAXIMUM 4-STEP MCADAM ELLIPSE BINNING TOLERANCE FOR COLOR

CONSISTENCY, AND MINIMUM EFFICACY OF 100 LUMENS/WATT. INITIAL LUMEN OUTPUT AS

INDICATED IN LUMINAIRE SCHEDULE.

4. DRIVER - REPLACEABLE, INTEGRAL, HIGH-EFFICIENCY DRIVER WITH MINIMUM 0.9 PF, OPERATING

VOLTAGE OF 120-277V, THERMAL MANAGEMENT, < 20% TOTAL HARMONIC DISTORTION. ON-OFF

CONTROL, STEP-DIMMABLE OR FULLY DIMMABLE AS INDICATED.

5. CERTIFICATION - UL 1598, DAMP LOCATION, DLC QUALIFIED, AND ROHS COMPLIANT. COMPLIES

WITH LM79, LM80 AND TM21 TESTING STANDARDS. UL 924 WHEN EQUIPPED WITH EMERGENCY

BATTERY BACK-UP.

6. MOUNTING - SURFACE ON CEILING OR SUSPENDED.

7. OPTIONS - WIRE GUARD, CHAIN, STEM OR SWIVEL STEM HANGERS.

8. THIS SKETCH IS A NON-PROPRIETARY GRAPHIC REPRESENTATION OF A LUMINAIRE THAT MAY MEET

THE SPECIFICATION REQUIREMENTS. IT IS NOT INTENDED TO INDICATE A CERTAIN MANUFACTURER

OR PREFERENCE.

WALL MOUNTED LED

REVISED: APRIL 2016 NL-9LIGHTING PLATE:

LUMINAIRE REQUIREMENTS:

1. HOUSING - DIE-FORMED, COLD-ROLLED STEEL, WITH REINFORCEMENT RIBS FOR RIGIDITY; END

CAPS SAME MATERIAL AS HOUSING, SECURED WITH TABS, SCREWS OR RIVETS. WHITE ENAMEL

FINISH APPLIED AFTER FABRICATION.

2. LENS - ACRYLIC PRISMATIC OR WHITE OPAL TO PROVIDE EVEN ILLUMINATION AND TO ELIMINATE

PIXILATION FROM LED LIGHT SOURCE.

3. LIGHT SOURCE - SOLID STATE LEDS WITH MINIMUM 50K HOURS RATED LIFE AT L70, 3500K CCT UON, MINIMUM 80 CRI, MAXIMUM 4-STEP MCADAM ELLIPSE BINNING TOLERANCE FOR COLOR

CONSISTENCY, AND MINIMUM EFFICACY OF 90 LUMENS/WATT. INITIAL LUMEN OUTPUT AS

INDICATED IN LUMINAIRE SCHEDULE.

4. DRIVER - REPLACEABLE, INTEGRAL, HIGH-EFFICIENCY DRIVER WITH MINIMUM 0.9 PF, OPERATING

VOLTAGE OF 120-277V, THERMAL MANAGEMENT, < 20% TOTAL HARMONIC DISTORTION. ON-OFF

CONTROL, STEP-DIMMABLE OR FULLY DIMMABLE AS INDICATED.

5. CERTIFICATION - UL 1598, DAMP LOCATION, DLC QUALIFIED, AND ROHS COMPLIANT. COMPLIES

WITH LM79, LM80 AND TM21 TESTING STANDARDS. UL 924 WHEN EQUIPPED WITH EMERGENCY

BATTERY BACK-UP.

6. MOUNTING - SURFACE.

7. OPTIONS - INTEGRAL MOTION SENSOR, EMERGENCY BACK-UP.

8. THIS SKETCH IS A NON-PROPRIETARY GRAPHIC REPRESENTATION OF A LUMINAIRE THAT MAY MEET

THE SPECIFICATION REQUIREMENTS. IT IS NOT INTENDED TO INDICATE A CERTAIN MANUFACTURER

OR PREFERENCE.

SURFACE LED WRAPAROUND

REVISED: APRIL 2016 NL-5LIGHTING PLATE:

LUMINAIRE REQUIREMENTS:

1. HOUSING - DIE-FORMED, COLD-ROLLED STEEL, WITH REINFORCEMENT RIBS FOR RIGIDITY;

ENDCAPS SAME MATERIAL AS HOUSING, SECURED WITH TABS, SCREWS OR RIVETS. OPTIONAL

LENGTHS OF 2FT OR 4FT.

2. FINISH - MULTI-STAGE PHOSPHATE BONDING TREATMENT FINISHED WITH HIGH-REFLECTANCE, WHITE POLYESTER POWDER COAT, PAINTED AFTER FABRICATION.

3. LENS - 100% VIRGIN ACRYLIC, CLEAR PRISMATIC DIFFUSER WITH MINIMUM 0.1 INCH THICKNESS, CONTINUOUSLY SUPPORTED ALONG SIDES OF LUMINAIRE.

4. LIGHT SOURCE - SOLID STATE LEDS WITH MINIMUM 50K HOURS RATED LIFE AT L70, 3500K CCT UON, MINIMUM 80 CRI, MAXIMUM 4-STEP MCADAM ELLIPSE BINNING TOLERANCE FOR COLOR

CONSISTENCY, AND MINIMUM EFFICACY OF 95 LUMENS/WATT. INITIAL LUMEN OUTPUT AS

INDICATED IN LUMINAIRE SCHEDULE.

5. DRIVER - REPLACEABLE, INTEGRAL, HIGH-EFFICIENCY DRIVER WITH MINIMUM 0.9 PF, OPERATING

VOLTAGE OF 120-277V, THERMAL MANAGEMENT, < 20% TOTAL HARMONIC DISTORTION. OPTIONAL

STEP-DIMMABLE OR FULLY DIMMABLE AS INDICATED.

6. CERTIFICATION - UL 1598, DAMP LOCATION, DLC QUALIFIED, AND ROHS COMPLIANT. COMPLIES

WITH LM79, LM80 AND TM21 TESTING STANDARDS. UL 924 WHEN EQUIPPED WITH EMERGENCY

BATTERY BACK-UP.

7. MOUNTING - SURFACE ON CEILING OR SUSPENDED.

8. THIS SKETCH IS A NON-PROPRIETARY GRAPHIC REPRESENTATION OF A LUMINAIRE THAT MAY MEET

THE SPECIFICATION REQUIREMENTS. IT IS NOT INTENDED TO INDICATE A CERTAIN MANUFACTURER

OR PREFERENCE.

REVISED: AUGUST 2004 NL-67LIGHTING PLATE:

EMERGENCY LIGHTING UNIT

INTENDED USE — IDEAL FOR WET LOCATION AREAS REQUIRING EMERGENCY LIGHTING THAT ARE

SUBJECT TO SATURATION WITH NON-MECHANICALLY DELIVERED WATER.

CONSTRUCTION — GRAY, COMPACT, LOW-PROFILE CONTEMPORARY DESIGN. ENGINEERING-GRADE

THERMOPLASTIC HOUSING IS IMPACT-RESISTANT, SCRATCH-RESISTANT AND CORROSION-PROOF.

RUGGED, HEAVY-DUTY, POLYCARBONATE CLEAR HOUSING LENS. UL94V-0 FAME RATING. UV-STABLE

RESIN RESISTS DISCOLORATION FROM NATURAL AND MAN-MADE LIGHT SOURCES.

OPTICS — LAMP COMPATIBILITY: TWO 7W WEDGE-BASED HALOGEN MR16 STYLE LAMPS , WITH 45

DEGREE ADJUSTABLE HEADS IN ALL DIRECTIONS.

ELECTRICAL — DUAL-VOLTAGE INPUT CAPACITY (120V/277V). EMERGENCY UNIT PROVIDED WITH

TEST SWITCH, STATUS INDICATOR AND RECHARGEABLE BATTERY. BATTERY: SEALED,

MAINTENANCE-FREE, LEAD CALCIUM BATTERY DELIVERS 90 MINUTE CAPACITY TO EMERGENCY

LAMPS.

INSTALLATION — WALL-MOUNT STANDARD. JUNCTION BOX HOLE PATTERN FOR 4” OCTAGON

MOUNTING. FLEXIBLE CONDUIT ENTRY. NOT INTENDED FOR CEILING MOUNTING.

LISTINGS — UL LISTED. WET LOCATION LISTED. STANDARD TEMPERATURE RATING 68°F TO 122°F (20° C TO 50°C). MEETS UL 924, NFPA 101(CURRENT LIFE SAFETY CODE), NFPA 70-NEC AND OSHA

ILLUMINATION STANDARDS.

THIS SKETCH IS A NON-PROPRIETARY GRAPHIC REPRESENTATION OF A LUMINAIRE THAT MAY MEET THE SPECIFICATION REQUIREMENTS. IT IS NOT INTENDED TO INDICATE A CERTAIN MANUFACTURER

OR PREFERENCE.

LUMINAIRE REQUIREMENTS:

13"

NOMINAL

NOMINAL

5"

MAX. DEPTH

4" NOMINAL

1.

2.

3.

4.

5.

6.

7.

BASEPLATE - MARINE GRADE DIE-CAST ALUMINUM. INTEGRAL HEAT SINKS. BASEPLATE FLANGE

INTERLOCKS AND WRAPS AROUND LENS BASE PRODUCING MAXIMUM MOISTURE DEFECTION AND

RESISTANCE TO PRYING. STANDARD MATTE BLACK, DARK BRONZE OR MATTE WHITE EXTERIOR TGIC

POLYESTER POWDER COAT – 5-STEP PRE-TREATMENT.

REFLECTOR/LENS - FULL REFLECTOR/WIRE COVER – 92% REFLECTIVITY. UV-STABILIZED, HIGH

IMPACT RESISTANT, VIRGIN INJECTION MOLDED POLYCARBONATE. HIGH EFFICIENCY LENS

MAXIMIZES UNIFORMITY. CLOSE TOLERANCE MATING OF INJECTION MOLDED LENS AND LENS BASE FACILITATES SET UP AND INSTALLATION. LENS AND LENS BASE SECURED WITH TWO CONCEALED

CAPTIVE TORX® WITH CENTER PIN FASTENERS.

LENS BASE/GRILLE - HIGH IMPACT RESISTANT, INJECTION MOLDED MATTE BLACK, DARK BRONZE OR

MATTE WHITE POLYCARBONATE. OPTIONAL LIGHT GRAY, SILVER, FOREST GREEN OR CUSTOM

COLOR ARE CHEMICALLY BONDED, IMPACT RESISTANT FINISHES

GASKETING - DIE-CUT, CLOSED CELL NEOPRENE SELF ADHESIVE GASKET SEALS BASEPLATE TO

MOUNTING SURFACE. CLOSED CELL, SILICONE “O” RING GASKETS POSITIONED AND FRICTION

SECURED IN GASKET CHANNELS OF LENS BASE, BASEPLATE AND OPTIONAL SURFACE ADAPTER.

ELECTRICAL - LED 3500K COLOR TEMPERATURE, 80 CRI. 120-277VAC, 50/60HZ ELECTRICAL INPUT WITH HIGH POWER FACTOR ELECTRONIC, CONSTANT-CURRENT DRIVER (>.90 PF). STANDARD 0-10V

DIMMING WITH 1-100% RANGE; MAXIMUM DRIVER SOURCE OF 200 ΜA.

PHOTOMETRICS - PHOTOMETRY TESTED TO THE IESNA LM-79-08 STANDARD BY AN ILAC/ISO17025

ACCREDITED LABORATORY.

LISTINGS - LUMINAIRE IS CERTIFIED TO UL STANDARDS BY EITHER UNDERWRITERS LABORATORY OR

INTERTEK TESTING LABORATORY FOR WET LOCATION (LISTING INCLUDES EMERGENCY BATTERY

PACK). UL CERTIFIED IP64 PER IEC 60598. ADA COMPLIANT.

THIS SKETCH IS A NON-PROPRIETARY GRAPHIC REPRESENTATION OF A LUMINAIRE THAT MAY MEET THE SPECIFICATION REQUIREMENTS. IT IS NOT INTENDED TO INDICATE A CERTAIN MANUFACTURER

OR PREFERENCE.

REVISED: AUGUST 2004 NL-62LIGHTING PLATE:

DECORATIVE EXTERIOR WALL-MOUNTED FIXTURE

11"

NOMINALNOMINAL

4"

FLUSH

LENS

UNDERNEATH

FOR CUTOFF-

FACE OPTION

LUMINAIRE REQUIREMENTS:

1.

2.

3.

4.

5.

6.

7.

REVISED: AUGUST 2004 NL-63LIGHTING PLATE:

LED EXIT SIGN

13"

NOMINAL

NOMINAL

9"

8.

CONSTRUCTION — DURABLE CAST ALUMINUM CONSTRUCTION – RUGGED, LOW-PROFILE HOUSING

IS .250 TO .525" THICK. NEMA 4X AND FPA (NSF LISTING) OPTION AVAILABLE FOR WET AND HOSE- DOWN APPLICATIONS. CLEAR, UV-STABLE POLYCARBONATE COVER IS .130" THICK TO PREVENT CRACKING OR BREAKING. COVER IS SECURED WITH FOUR STAINLESS STEEL, TORX T20 TAMPER-

RESISTANT SCREWS WITH CENTER PIN. POLYCARBONATE FACEPLATE INCORPORATES UNIVERSAL

DIRECTIONAL CHEVRON KNOCKOUTS THAT ARE CONCEALED AND EASILY REMOVED AND REPLACED.

UNIVERSAL MOUNT (UM) OPTION AVAILABLE – TOP, BACK, END MOUNTING OR CONDUIT ENTRY

(CANOPY PROVIDED). LETTERS 6" HIGH WITH 3/4" STROKE, WITH 100 FT VIEWING DISTANCE RATING, BASED UPON UL924 STANDARDS.

OPTICS — LAMP IS CONSTRUCTED USING NEW LED TECHNOLOGY. PROVIDES PERFECTLY UNIFORM ILLUMINATION. THE TYPICAL LIFE OF THE EXIT LED LAMP IS 10 YEARS. SINGLE-FACE EXIT USES ONE

LED LAMP; DOUBLE-FACE EXIT USES TWO LED LAMPS.

ELECTRICAL — DUAL VOLTAGE INPUT CAPABILITY (120/277V).

INSTALLATION — BACK MOUNT STANDARD FOR SINGLE FACE (NO CANOPY), UNLESS UNIVERSAL

MOUNT (UM) SPECIFIED. CONDUIT ENTRY (1/2" - 14 UNC) INCLUDED WITH UNIVERSAL MOUNTING.

CAST-ALUMINUM CANOPY ATTACHES TO 10-GAUGE STEEL MOUNTING PLATE FOR TOP OR END

MOUNTING (NOT REQUIRED FOR BACK MOUNTING).

LISTINGS — UL LISTED. LISTED AND LABELED TO COMPLY WITH CANADIAN STANDARDS C-860 AND C22.2 NO. 9 4X OPTION IS UL LISTED TO NEMA 4X RATINGS. NSF CERTIFIED. MEETS UL 924, NFPA 101

(CURRENT LIFE SAFETY CODE), NEC AND OSHA ILLUMINATION STANDARDS

THIS SKETCH IS A NON-PROPRIETARY GRAPHIC REPRESENTATION OF A LUMINAIRE THAT MAY MEET THE SPECIFICATION REQUIREMENTS. IT IS NOT INTENDED TO INDICATE A CERTAIN MANUFACTURER

OR PREFERENCE.

LUMINAIRE REQUIREMENTS:

1.

2.

3.

4.

5.

6.

ROUND LED PENDANT

REVISED: APRIL 2016 NL-15LIGHTING PLATE:

LUMINAIRE REQUIREMENTS:

1. HOUSING - STEEL FRAME AND VERTICAL PENDANT STEM FINISHED IN SATIN NICKEL OR CHROME.

STAINLESS STEEL SUPPORT WIRES FROM TOP CEILING PLATE FOR BRACING AND SUPPORT.

FABRIC OUTER SHADE AVAILABLE IN VARIOUS COLORS AND TEXTURES.

2. BOTTOM LENS - ETCHED GLASS TO PREVENT PIXILATION OF LED LIGHT SOURCES AND ROUND

FINIAL AT BOTTOM TO SUPPORT LENS IN SHADE. FINIAL TO MATCH LUMINAIRE FINISH.

3. LIGHT SOURCE - SOLID STATE LEDS WITH MINIMUM 50K HOURS RATED LIFE AT L70, 3500 CCT UON, MINIMUM 80 CRI, MAXIMUM 4-STEP MCADAM ELLIPSE BINNING TOLERANCE FOR COLOR

CONSISTENCY, AND MINIMUM EFFICACY OF 90 LUMENS/WATT. INITIAL LUMEN OUTPUT AS

INDICATED IN LUMINAIRE SCHEDULE.

4. DRIVER - REPLACEABLE, INTEGRAL, HIGH-EFFICIENCY DRIVER WITH MINIMUM 0.9 PF, OPERATING

VOLTAGE OF 120-277V, THERMAL MANAGEMENT, <20% THD. ON-OFF CONTROL OR FULLY DIMMABLE

AS INDICATED.

5. CERTIFICATION - UL 1598, DAMP LOCATION, DLC QUALIFIED, AND ROHS COMPLIANT. COMPLIES

WITH LM79, LM80 AND TM21 TESTING STANDARDS.

6. MOUNTING - SUSPENDED FROM HARD OR ACOUSTICAL TILE CEILING.

7. OPTIONS - VARIOUS SHADE FABRIC COLORS AND TEXTURES, WARMER 3000K CCT.

8. THIS SKETCH IS A NON-PROPRIETARY GRAPHIC REPRESENTATION OF A LUMINAIRE THAT MAY MEET

THE SPECIFICATION REQUIREMENTS. IT IS NOT INTENDED TO INDICATE A CERTAIN MANUFACTURER

OR PREFERENCE.

J

J J

J J

J

J

J

VENDING

LOUNGE

STORAGE

153 STAIR #2

1S2

DUTY

DUTY QTRS

OFFICE

FIRE ALARM

RESTROOM

JAN

CORRIDOR

VESTIBULE

KITCHEN

SLEEP

SLEEP

TLT

104A

SLEEP

SLEEP

SLEEP

SLEEP

TLT

108A

SLEEP

SLEEP

SLEEP

SLEEP

TLT

112A

SLEEP

SLEEP

SLEEP

SLEEP

TLT

116A

SLEEP

SLEEP

SLEEP

SLEEP

TLT

120A

SLEEP

SLEEP

SLEEP

SLEEP

TLT

105A

TLT

109A

TLT

113A

TLT

117A

TLT

121A

TLT

124A

MECHAN…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .