Drawings_Vol-5_817CM3025_Marion NC.pdf
PDF 9 MB Posted
- Solicitation number
- 36C78625B0035
About this file
These architectural drawings detail the design for a new administrative building at Marion National Cemetery in Marion, Indiana. The project involves constructing a single-story, approximately 4,014 gross square foot Type V (000) construction building classified as a Group "B" Business Occupancy. The building will include multiple functional spaces such as a lobby, general office, individual offices, breakroom, multi-purpose room, restrooms, mechanical rooms, and support areas like an IT closet and storage rooms. The structure features a standing seam metal roof with a 4:12 pitch, brick veneer exterior with an air space, and will be fully compliant with 2018 building codes, VA barrier-free design standards, and accessibility requirements. The design emphasizes functionality with careful attention to fire safety, accessibility, and efficient space utilization for cemetery administration operations.
View the file
Other files
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
274 SF
LOBBY
719 SF
GENERAL
OFFICE
140 SF
OFFICE
226 SF
ASSISTANT
DIRECTOR
OFFICE
28 SF
SECURE
STORAGE
ROOM
214 SF
WORK
ROOM
39 SF
ELEC
CLOSET
138 SF
IT CLOSET &
STORAGE
190 SF
MECHANICAL
ROOM
385 SF
MULTI
PURPOSE
ROOM
57 SF
MEN'S
TOILET
57 SF
WOMEN'S
TOILET 323 SF
BREAKROOM197 SF
WOMEN'S
TOILET
190 SF
MEN'S
TOILET
EXIT
'-0
T R
A V
E L
D
IS
T A
N C
E
EXIT
119 SF
100A
VESTIBULE
100'-0"
TRAVEL DISTANCE
EWC
'-0
T R
A V
E L
D
IS
T A
N C
E
FEC
FE
FEC
LIFE SAFETY SYMBOLS
SMOKE TIGHT
ASSEMBLY
1 HOUR FIRE
BARRIER
2 HOUR FIRE
BARRIER
3 HOUR FIRE
BARRIER
1 HOUR FIRE &
SMOKE BARRIER
2 HOUR FIRE &
SMOKE BARRIER
3 HOUR FIRE &
SMOKE BARRIER
HE
TRAVEL DISTANCE
100'-10"
TRAVEL DISTANCE
EA
EDEXIT EXIT
HORIZONTAL EXIT
EXIT DISCHARGE
EXIT ACCESS
FIRE
EXTINGUISHER
FE
FIRE
EXTINGUISHER
CABINET
FEC
LIMITS OF
CONSTRUCTION
SMOKE
COMPARTMENT
BOUNDARY
HEALTH CARE
SUITE
NOTE: NOT ALL SYMBOLS MY BE USED ON EACH PLAN
OCCUPANCY
SEPARATION
SHAFT
ADJACENT SYMBOLS SHOW PARTITION RATING AND
DAMPER REQUIREMENTS
HAZARDOUS USE
ADJACENT SYMBOLS SHOW PARTITION RATING.
OPENINGS REQUIRE CLOSER & LATCH
EXIT PASSAGEWAY
RATE AS STAIR
ALL OPENINGS TO BE RATED AS STAIR SHAFT
CORRIDOR
WALLS TO LIMIT THE TRANSFER OF SMOKE
ADJUNCT CORRIDOR or PSYCHIATRIC AREA or CONSTRUCTED WITH MIN. 4'-0" CLEAR
WITH (PER CHAPTER 19)
NOYES
APPLICABLE REGULATIONS
GENERAL TYPE OF PROJECT
NFPA NATIONAL FIRE CODES (EXCEPTION: NFPA 5000 & 900)
2018 NFPA 101 (LIFE SAFETY CODE)
ABA STANDARDS (2015) (ABAAS)
2018 IBC
REMODEL
ADDITION
NEW BUILDING
PROJECT DESCRIPTION
CODE SUMMARY
NEW CONSTRUCTION OF APPROXIMATELY 4,014 GSF TYPE V
(000) CONSTRUCTION, GROUP "B" BUSINESS OCCUPANCY.
UPGRADE FACILITIES TO ACCESSIBILITY CODE.
VA BARRIER FREE DESIGN STANDARD (PG-18-13)
NOYESAUTHORITIES HAVING JURISDICTION (AHJ's)
THE JOINT COMMISSION (TJC)
CENTER FOR MEDICARE/MEDICAID SERVICES (CMS)
TESTRATING (HRS)
TOTAL
EXTERIOR DOORS AND WINDOWS
EXIT PASSAGEWAYS
OTHER
ROOF CONSTRUCTION
PRIME & SEC. FLOOR BEAMS, JOISTS
FLOOR/CEILING ASSEMBLY
FLOOR CONSTRUCTION
INTERIOR
NON-BEARING WALLS AND PARTITIONS
BEARING WALLS
COLUMNS
GIRDERS
TRUSSES
ROOF/CEILING ASSEMBLY
PRIME & SEC. ROOF BEAMS, JOISTS
EXTERIOR
INTERIOR BEARING WALLS
EXTERIOR BEARING WALLS
STRUCTURAL FRAME
AREA SEPARATIONS / FIRE WALLS
FIRE-RESISTIVE REQUIREMENTS
TYPE(S) OF CONSTRUCTION
ACTUAL AREA PER FLOOR
CONSTRUCTION TYPE(S)
1ST FLOOR - NEW
NONE
PLUMBING FIXTURES
TOILETS
LAVATORIES
DRINKING FOUNTAINS
SERVICE SINKS
PROVIDED RQD FACTOR
1 M, 1 F 1/25 for first 50 occupants, then 1/50 1/40 for first 80 occupants, then 1/80 1/100 occupants. 50% may be vending1
OCCUPANT LOAD OF BUILDING
SF/OCCUPANT OCCUPANTSAREA
TOTAL OCCUPANTS:
4,014 GSF
4,014 GSF
150 SF / OCC. 27 OCC.
ZERO NA
NA
(IBC CH 29)
TYPE V [000] (NFPA 220 TABLE 4.1.1)
OSHA STANDARDS
VA SEISMIC DESIGN REQUIREMENTS H-18-8
NATIONAL ELECTRIC CODE (NEC)
ASME BOILER AND PRESSURE VESSEL CODE
ASME CODE FOR PRESSURE PIPING
BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE,
AMERICAN CONCRETE INSTITUTE AND COMETARY (ACI 318)
MANUAL OF STEEL CONSTRUCTION, LOAD AND RESISTANCE
FACTOR DESIGN SPECIFICATIONS FOR STRUCTURAL STEEL
BUILDINGS, AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC)
ENERGY POLICY ACT OF 2005 (EPAct)
DOE INTERIM FINAL RULE: ENERGY CONSERVATION STANDARDS
FOR NEW FEDERAL, COMMERCIAL AND MULTI-FAMILY HIGH-RISE
RESIDENTIAL BUILDINGS AND NEW LOW-RISE RESIDENTIAL
BUILDINGS, 10 CFR PARTS 433,434 AND 435
FEDERAL LEADERSHIP IN HIGH PERFORMANCE AND SUSTAINABLE
BUILDINGS: MEMORANDUM OF UNDERSTANDING (MOU)
EXECUTIVE ORDER 13834
THE PROVISIONS FOR CONSTRUCTION AND SAFETY SIGNS. STATED
IN THE GENERAL REQUIREMENTS SECTION 01010 OF THE VA
MASTER CONSTRUCTION SPECIFICATION
VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY - ASHRAE
STANDARD 62.1-2004
SAFETY STANDARD FOR REFRIGERATION SYSTEMS - ASHRAE
STANDARD 15 -2007
VA FIRE PROTECTION DESIGN MANUAL
VA DIRECTIVES, DESIGN MANUALS, MASTER SPECIFICATIONS, VA
NATIONAL CAD STANDARD APPLICATION GUIDE, AND OTHER
GUIDANCE ON THE TECHNICAL INFORMATION LIBRARY (TIL)
MEANS OF EGRESS CAPACITY (width in inches)
EGRESS
36 INCHES
ACCESSIBLE MEANS OF EGRESS ("MOE") REQUIRED
NO CHANGE
BUILDING HEIGHT
(IBC Section 503)ALLOWABLE AREA PER FLOOR
BASIC ALLOWABLE AREA
NOYES
(Section 8.3)
CHANGE OF OCCUPANCY?
SEPARATED OCCUPANCIES?
FIRE BARRIER RATING(S) SEE LIFE SAFETY PLANS
OCCUPANCY CLASSIFICATION(S)
OCCUPANCIES
(If Remodeling)
2018 LSC (TABLE 6.1.14.1)
SPECIAL PURPOSE INDUSTRIAL
NOYES
FIRE RESISTIVE CORRIDORS?
SMOKE TIGHT CORRIDORS (SMOKE PARTITIONS)
MISCELLANEOUS
INTERIOR FINISHES CLASSIFICATION B
9,000 GSF
1 M, 1 F2 M, 1 F
4 M, 1 F
NA
NA
NA
NA
ZERO
ZERO
ZERO
ZERO
ZERO
ZERO / 1-HR UL U419
ZERO NA
ZERO NA
ZERO / 1-HR UL K506
ZERO NA
ZERO NA
ZERO NA
FULLY SPRINKLERED BUILDING
BUSINESS 4,014 GSF
27 OCC.
BLDG NON-SPRINKLERED
5.4"(occupant load x capacity factor) 27 x 0.2
MINIMUM DOOR WIDTH
YES
EXIT ACCESS TRAVEL DISTANCE - Occupancy "B" (non-sprinkered)
200 FEET
MAX
MAX. DEAD END EGRESS PATH - (non-sprinklered) 20 FEET
COMMON PATH OF TRAVEL - (non-sprinklered) 75 FEET
(Provide 1-Hour rated walls at "IT CLOSET" room)
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTSOffice of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
BID DOCUMENTS
OF XXX
TECHNOLOGY:
IMEG
11044 RESERCH BLVD A-230
AUSTIN, TX 78759
309.786.5092
JAYSON STICKROD, PE
IRRIGATION:
EC DESIGN GROUP, LTD
400 5TH STREET
WEST DES MOINES, IA 50265
515.225.6365
GEOTECHNICAL:
TERRACON
7770 WEST NEW YORK ST.
INDIANAPOLIS, IN 46214
317.746.7925
RICHARD D. OLSON, PE
COST ESTIMATING:
CPMI
1001 GRAND AVE, SUITE 201
WEST DES MOINES, IA 50265
515.244.1166
BRYAN BERTRANDERIK CHRISTIANSEN, ASIC
BUILDING 1001
C U s e rs \p c h o i\ D o c u m e n ts
\1
P
IC
A d m in is tr a ti o n
R
Y e u n y o u n g .r v t
/2 /2
:3
:3
P
M
PIC ADMIN. BLDG - 1ST FLOOR LIFE SAFETY
PLAN
MARION NATIONAL CEMETRY
NEW LAND EXPANSION
1700 E 38TH ST, MARION, IN 46953
817CM3023
OCTOBER 30, 2024 LA PC17101
1001-GI111
1/8" = 1'-0"
LIFE SAFETY PLAN
0 8' 16'4'
Revisions: Date:
OF 266110110 OF 266110
AE201
2AE201
LOBBY
GENERAL
OFFICE
OFFICE
ASSISTANT
DIRECTOR
OFFICE
SECURE
STORAGE
ROOM
MEN'S
TOILET
WOMEN'S
TOILET
IT CLOSET &
STORAGE
MECHANICAL
ROOM
ELEC
CLOSET
MULTI
PURPOSE
ROOM
MEN'S
TOILET
WOMEN'S
TOILET
HALLWAY
WORK
ROOM
BREAKROOM
101.1
7.
8.
6.
1 11 4.
5.
2.
110.1
111.1
107.1
8.
105.1
3.
4.
1AE211 13
AE211
AE211
0A
.1
AE211
113.1
JANITOR
100A
VESTIBULE
AE211
AE211
B3
B3
B3b
B6bs
B3b B6bs
CR
CRCR
B6
AE311
AE311
AE312
AE311
1 2 3 4
B
C
D
E
F
DASHED LINE
INDICATES GLUE
LAMINATED BEAM
ABOVE
FE
B3bp
B3b B6s
CR
1.2 1.8
A
B3b
AE301
B.2
HEADER
ABOVE
FEC
DASHED LINE
INDICATES ROOF
EDGE ABOVE, TYP
DOWNSPOUT, TYP
0.
B6p
B3
B3
AE312
AE301
B3b B3b
B3
B3
A3
B3
W1 W1 W1 W1 W1 W1 W1 W1
W1
W1
W1
W1
W1
W1
W1W1W1W1W1
HM1
B6ps
SF01
SF02
SF03
LOBBY
GENERAL
OFFICE 103
OFFICE
ASSISTANT
DIRECTOR
OFFICE
SECURE
STORAGE
ROOM
WORK
ROOM
BREAKROOM
HALLWAY
MEN'S
TOILET
MULTI
PURPOSE
ROOM
WOMEN'S
TOILET
IT CLOSET &
STORAGE
MECHANICAL
ROOM
MEN'S
TOILET
WOMEN'S
TOILET
ELEC
CLOSET
100A
VESTIBULE
JANITOR
AFF9'-0"
AFF9'-0"
AFF9'-0"
AFF8'-0" AFF8'-0"
AFF9'-0"
AFF8'-0"
AFF8'-0"
AFF9'-0"
AFF8'-0"
AFF9'-0"
AFF9'-0"
AFF9'-0"
AFF9'-0"AFF8'-0"
AE550
1 2 3 4
B
C
D
E
F
1.2 1.8
A
2' -1
/8
16'-5 7/8"
1' -2
/8
B.2
AE601
TYP
ABOVE CLG
AE601
AE601
TYP
ABOVE CLG
TYP
ABOVE CLG
GENERAL NOTES
1. THE ARCHITECTURAL DRAWINGS SHOW PRINCIPAL AREAS AND LIMITS OF
CONSTRUCTION WHERE WORK MUST BE ACCOMPLISHED UNDER THIS CONTRACT.
INCIDENTAL WORK MAY BE NECESSARY IN AREAS NOT SHOWN ON ARCHITECTURAL
DRAWINGS DUE TO CHANGES AFFECTING ELECTRICAL, MECHANICAL AND PLUMBING
ALONG WITH OTHER SYSTEMS. THIS INCIDENTAL WORK SHALL BE PART OF THIS
CONTRACT, AND ALL TRADES SHALL INSPECT THESE AREAS, ASCERTAIN WORK
REQUIRED AND DO THE WORK IN ACCORDANCE OF CONTRACT REQUIREMENTS AT
NO ADDITIONAL COST.
2. CONTRACTORS SHALL VISIT THE SITE DURING BIDDING TO BECOME FAMILIAR WITH
THE EXISTING CONDITIONS. THE GENERAL CONTRACTOR SHALL LOCATE, INSPECT
AND FIELD VERIFY ALL EXISTING CONDITIONS, DIMENSIONS AND ELEVATIONS PRIOR
TO DEMOLITION AND CONSTRUCTION. NOTIFY ARCHITECT IMMEDIATELY OF ANY
DISCREPANCIES.
3. DO NOT SCALE DRAWINGS. NOTIFY ARCHITECT IMMEDIATELY OF ANY
DISCREPANCIES.
4. WHEREVER OPENINGS ARE CUT THROUGH FIRE RATED PARTITIONS, IT SHALL BE
THE RESPONSIBILITY OF THE CONTRACTOR FOR WHOM THE HOLE IS CUT TO PATCH
AND REPAIR ANY OPENING TO MAINTAIN THE INTEGRITY OF THE FIRE RATING.
5. GENERAL CONTRACTOR TO CHECK MECHANICAL DRAWINGS FOR EXISTING PIPES
AND DUCTS FURRED IN WALLS. VERIFY SIZE AND LOCATION WITH MECHANICAL
CONTRACTOR PRIOR TO PROCEEDING WITH REMODELING.
6. FIREPROOFING SHALL BE UNPIERCED. ANY SUBCONTRACTOR PENETRATING THE
FIREPROOFING SHALL BE REQUIRED TO REPLACE FIREPROOFING TO THE ORIGINAL
CONDITION AND FIRE RATING, AT THE SUBCONTRACTORS EXPENSE.
7. EQUIPMENT UNIT DIMENSIONS ARE FOR PRODUCT DESCRIPTION ONLY, VERIFY SIZE
WITH MANUFACTURER.
8. ALL DIMENSIONS PERTAINING TO MECHANICAL OR ELECTRICAL SERVICES OR
EQUIPMENT SHALL BE VERIFIED WITH THE RESPECTIVE TRADE.
9. ALL CONTRACTORS THAT PENETRATE AND/OR DISTURB ANY AREAS AT EXISTING
CONDITIONS SHALL PATCH AREA TO MATCH EXISTING ADJACENT AREA OR
SURFACE AND PREPARE FOR SCHEDULED FINISH APPLICATION. COORDINATE WORK
WITH GENERAL CONTRACTOR PRIOR TO PROCEEDING.
10. VERIFY HEIGHTS AND LOCATIONS OF ACCESS PANELS (AP) AND COORDINATE
TYPES WITH TRADES WHICH REQUIRE THEM.
11. PROVIDE LINTELS AND FRAMING FOR GRILLES, LOUVERS, AND ROOF VENTS AS
REQUIRED BY MECHANICAL CONTRACTOR, VERIFY SIZE AND LOCATION.
12. STRUCTURAL, MECHANICAL, AND ELECTRICAL ABBREVIATIONS AND SYMBOLS MAY
DIFFER FROM ARCHITECTURAL. SEE RESPECTIVE SECTIONS AND/OR DRAWINGS FOR
DEFINITIONS.
13. AT MECHANICAL AND ELECTRICAL EQUIPMENT ROOMS, PROVIDE 3/4" FRT
PLYWOOD BACKING BEHIND ALL SURFACE MOUNTED FIXTURES AND EQUIPMENT,
UNLESS NOTED OTHERWISE.
14. CONTRACTOR SHALL EVALUATE INTEGRITY OF ALL PARTITIONS INDICATED BY
SYMBOLS ON THE LIFE SAFETY PLAN(S) WITHIN THE PROJECT SCOPE AND UPGRADE
AS REQUIRED. ALL FIRE RESISTIVE RATED WALLS SHALL BE CONSTRUCTED OF
MATERIALS / ASSEMBLIES MEETING THE RATING INDICATED, TERMINATE AT THE
DECK ABOVE WITH A TESTED HEAD OF WALL ASSEMBLY AND ALL PENETRATIONS
SHALL BE SEALED WITH A TESTED ASSEMBLY. ALL SMOKE PARTITIONS SHALL BE
CONSTRUCTED OF MATERIALS THAT RESIST THE PASSAGE OF SMOKE, TERMINATE
AT THE DECK ABOVE WITH A JOINT SEALED WITH FIRE CAULK AND ALL
PENETRATIONS SHALL BE SEALED WITH FIRE CAULK.
RCP GENERAL NOTES
1. GENERAL CONTRACTOR TO COORDINATE ALL CEILING MOUNTED EQUIPMENT
SUPPORT REQUIREMENTS, LOCATIONS, DIMENSIONS, ETC WITH EQUIPMENT
SUPPLIER AND OWNER, PRIOR TO INSTALLATION.
2. ALL CEILING MOUNTED ITEMS SUCH AS LIGHT FIXTURES, GRILLES, DIFFUSERS,
SPEAKERS, EXIT LIGHTS, ETC SHALL BE LOCATED IN THE CENTER OF ACT PANELS,
GYP BD SOFFITS AND/OR PLASTER SOFFIT BAYS, UNLESS NOTED OTHERWISE.
COORDINATE WITH MECHANICAL AND ELECTRICAL DRAWINGS.
3. FINISHED GYP BD SOFFITS SHALL EXTEND 1" BEYOND FACE AND EXPOSED ENDS
OF WALL CABINETS, FULL-HEIGHT CABINETS, ETC UNLESS NOTED OTHERWISE.
COORDINATE CABINET DIMENSIONS WITH SUPPLIER. GYP BD FASCIA/SOFFIT
DETAILS ARE REFERENCED FROM THE REFLECTED CEILING PLAN.
4. SEE MECHANICAL DRAWINGS FOR SPRINKLER HEAD TYPES AND LOCATIONS.
CENTER ALL HEADS IN ACT UNLESS NOTED OTHERWISE.
5. AT REMODELING WORK IN EXISTING ACT SUSPENSION SYSTEM, REMOVE EXISTING
PANELS, CUT AS REQUIRED FOR CONSTRUCTION AND RE-INSTALL. REPLACE ALL
DAMAGED AND / OR EXTREMELY SOILED PANELS WITH ACT TO MATCH EXISTING.
REFLECTED CEILING PLAN SYMBOLS
NOTE: NOT ALL SYMBOLS MAY BE USED ON EACH PLAN
GBPD
CEILING /
SOFFIT
ACT CEILING
SYSTEM
EXISTING
ACT CEILING
SYSTEM
IV TRACK
CUBICLE
CURTAIN
TRACK
ACCESS
PANEL
2'-0" x 4'-0"
LIGHT FIXTURE
2'-0" x 2'-0"
LIGHT FIXTURE
PENDANT STRIP
LIGHT FIXTURE
PENDANT STRIP
LIGHT FIXTURE
RECESED LIGHT
FIXTURE
MECHANICAL
SUPPLY GRILL
MECHANICAL
RETURN GRILL/
RECESSED
LIGHT FIXTURE
WALL SCONCE
LIGHT FIXTURE
MECHANICAL
LINEAR SUPPLY
GRILL
CEILING
ELEVATION AND
FINISH
9'-0" AFF
ACT
FLOOR PLAN SYMBOLS
EXISTING WALL TO
REMAIN
WALL
EXISTING DOOR
AND FRAME TO
REMAIN
DOOR
INTERIOR
BORROWED LIGHT
101B
1A
8'-0"
DIMENSION LINE,
NOMINAL
8'-0" EXTENDED
DIMENSION LINE,
NOMINAL
AE2111A
INTERIOR
ELEVATION
INDICATOR TAG
2B
AE2O1
EXTERIOR
ELEVATION
INDICATOR TAG
1A
203 EQUIPMENT TAG
100 FLOOR SPOT
ELEVATIONWALL TAG
OFFICE
ROOM NAME AND
NUMBER AE501
1A
DETAIL REFERENCE
TAG
AE2O1
EXTERIOR SECTION
REFERENCE TAG
1A
AE2O1
INTERIOR SECTION
REFERENCE TAG
1A
KEY NOTE
A GRIDLINE
REVISION TAG
PR01
REVISION CLOUD
NOTE: NOT ALL SYMBOLS MAY BE USED ON EACH PLAN
FP10
B3
W1
WINDOW, LOUVER
OR CURTAINWALL
TAG
1 2 3 4
B
C
D
E
F
1.2 1.8
A
B.2
'-8
LOBBY
GENERAL
OFFICE
OFFICE
ASSISTANT
DIRECTOR
OFFICE
SECURE
STORAGE
ROOM
MEN'S
TOILET
WOMEN'S
TOILET
IT CLOSET &
STORAGE
MECHANICAL
ROOM
ELEC
CLOSET
MULTI
PURPOSE
ROOM
MEN'S
TOILET
WOMEN'S
TOILET
HALLWAY
WORK
ROOM
BREAKROOM
101.1
7.
8.
6.
1 11 4.
5.
2.
110.1
111.1
107.1
8.
105.1
3.
4.
'-0
C
LE
A R
5' -0
'-2
24'-8" 3'-4" 2'-0" 3'-4" 4'-4" 5'-4" 10'-0" 4'-0"
1'-4"
3'-4" 5'-8" 3'-4" 2'-0" 3'-4" 2'-0" 3'-4" 4'-8"
'-4
2'
-0
8' -0
'-8
'-0
2' -8
3'
-4
2' -0
3'
-4
9' -4
3'
-4
2' -0
3'
-4
6' -0
3'
-4
2' -0
3'
-4
2' -8
4'-0" 3'-8" 6'-0" 3'-8" 8'-0" 3'-4" 2'-0" 3'-4" 8'-0" 3'-4" 2'-0" 3'-4" 6'-0" 3'-4" 2'-0" 3'-4" 7'-4" 3'-4" 2'-0" 3'-4" 4'-8"
5' -0
'-1
'-1
1"
0A
.1
113.1
JANITOR
100A
VESTIBULE
AE211
AE211
6' -4
3'
-1 0"
7' -2
B3
B3
B3b
B6bs
B3b B6bs
2' -4
CR
CRCR
B6
1'-0"
1'-0" 1'-0" 13'-4" 1'-0" 1'-0"
1'-0"
'-6
2'
-0
8' -0
'-2
'-8
86'-0"
3'-0" 15'-4" 3'-0" 36'-8" 28'-0"
FE
B3bp
B3b B6s
CR
B3b
E Q
'-2
E Q
6' -0
11'-6 1/4" 17'-11"
19'-9" 16'-3" 12'-0" 8'-10"
2"
5'-7"
HEADER
ABOVE
FEC
0.
B6p
B3
B3
1' -0
1'
-0
5' -0
6"
5' -0
10'-0" 12'-6" 6'-0" 22'-2"
B3bB3b
B3
B3
A3
86'-0"
5'-0" 21'-6"
B3
7' -2
1' -6
7' -2
2' -2
1' -2
6'-0 1/4" 5'-11"
2'-4"
W1 W1 W1 W1 W1 W1 W1 W1
W1
W1
W1
W1
W1
W1
W1W1W1W1W1 L2
L1
SF01
SF02
SF03
HM1
1' -6
5'
-0
CL
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTSOffice of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
BID DOCUMENTS
OF XXX
TECHNOLOGY:
IMEG
11044 RESERCH BLVD A-230
AUSTIN, TX 78759
309.786.5092
JAYSON STICKROD, PE
IRRIGATION:
EC DESIGN GROUP, LTD
400 5TH STREET
WEST DES MOINES, IA 50265
515.225.6365
GEOTECHNICAL:
TERRACON
7770 WEST NEW YORK ST.
INDIANAPOLIS, IN 46214
317.746.7925
RICHARD D. OLSON, PE
COST ESTIMATING:
CPMI
1001 GRAND AVE, SUITE 201
WEST DES MOINES, IA 50265
515.244.1166
BRYAN BERTRANDERIK CHRISTIANSEN, ASIC
BUILDING 1001
C U s e rs \p c h o i\ D o c u m e n ts
\1
P
IC
A d m in is tr a ti o n
R
Y e u n y o u n g .r v t
/2 /2
:3
:3
P
M
PIC ADMIN. BLDG - 1ST FLOOR PLAN AND RCP MARION NATIONAL CEMETRY
NEW LAND EXPANSION
1700 E 38TH ST, MARION, IN 46953
817CM3023
OCTOBER 30, 2024 LA PC17101
1001-AE111
1/8" = 1'-0"
FLOOR PLAN
0 8' 16'4' 1/8" = 1'-0"
REFLECTED CEILING PLAN
0 8' 16'4'
Revisions: Date:
1/8" = 1'-0"
DIMENSION PLAN
0 8' 16'4'
OF 266111111 OF 266111
ROOF SLOPE
4:12ROOF SLOPE
4:12
R O
O F
S
LO
P E
4:
R O
O F
S
LO
P E
4:
DASHED LINE INDICATES
EXTERIOR FACE OF WALL BELOW
STANDING SEAM
METAL ROOF
2'-0"2'-0"
2' -0
2'
-0
2'-0" 3'-0" 15'-4" 3'-0"
RIDGE
VENT
VENT
AE112
AE112
GUTTER
GUTTER
1 2 3 4
B
C
D
E
F
'-3
/8
ROOF SLOPE
4:12
ROOF SLOPE
4:12
1' -0
2'
-0
2'-0" 1'-0"
METAL SNOW GUARD
METAL SNOW GUARD
METAL SNOW
GUARD
1.2 1.8
A
AE301
B.2
21'-4"
DASHED LINE INDICATES
FACE OF COLUMN BELOW
METAL SNOW
GUARD
METAL SNOW GUARD
AE112
AE112
AE112
AE112
AE312
AE301
AE112
ROOF VENT SYSTEM
STANDING SEAM METAL
ROOF
1/2" EXTERIOR GYP SHEATHING
3/4" PLYWD
SHEATHING
UNDERLAYMENT
2 X 6 WOOD TRUSS
MIN
1 3/4"
MIN OPENING
1"
SEALANT AT ALL
GAPS
BASE FLASHING
UNDER CORVENT
PROVIDE CONTINUOUS BUTYL TAPE
AT ALL SCREW ATTACHMENT
POINTS PER MANUFACTURERS
RECOMMENDATION
20 GAUGE PRE-FINISHED
METAL TO MATCH THE COLOR
OF THE METAL ROOF OVER
WATERPROOF
UNDERLAYMENT
FASTENERS, TYP
EXHAUST
AIR
H O
T A
IR
DUCT - SEE MECH FOR SIZE
STAINLESS STEEL HOSE CLAMP
30# FELT
FIELD CUT HOLE 1" MIN LARGER THAT
PIPE. CENTER PIPE PENETRATION IN
PANEL. SEAL. PENETRATION THRU
CONTINUOUS VAPOR BARRIER
MEMBRANE PER TYVEK MEMBRANE
MANUFACTURER'S RECOMMENDATIONS.
SNAP - SEAM
PANEL SHOWN
TOP OF MASONRY
111'-4"
F
2'-0"
DRIP EDGE
8 MIL VAPOR RETARDER
CONT FASTEN TO
BLOCKING
WOOD BLOCKING -
SEE STRUCTURAL
2x14 WOOD
BLOCKING -
SEE STRUCTURAL
WOOD TRUSS WITH
11 3/4" HEEL
BATT INSULATION R=40
(2) 1 1/2" DIA HOLES IN THE
2x14 WOOD BLOCKING
BETWEEN EACH TRUSS
INSULATION BAFFLE
2" AIR SPACE
16 GAUGE ALUM
FLASHING WITH
DRIP
SEALANT AND BACKER ROD
BRICK VENEER
3" DEEP SPRAY FOAM INSULATION
ADJUSTABLE CAVITY WALL TIE
5/8" PLYWOOD EXT SHEATHING
AIR AND MOISTURE BARRIER
6" METAL STUDS
5/8" GYP BD
LINEAR VENT
STANDING SEAM
METAL ROOF
UNDERLAYMENT
1/2" EXTERIOR GYP SHEATHING
CLOSURE TRIM PIECE FLASHING BY
METAL ROOF MANUFACTURER
UNCLEATED 22 GA SHEET METAL
FASCIA SLIPPED UNDERNEATH
ROOFING PLIES. PROVIDE SLOTTED
HOLES AT TOP EDGE OF FASCIA FACE
FOR ATTACHMENT TO BEAM TO ALLOW
FOR EXPANSION
3/4" PLYWOOD
ALUMINUM
PREFINISHED
SOFFIT PANEL
6" ALUMINUM GUTTER
PREFINISHED WHITE
DEBRIS SCREEN
BATT INSULATION
7"
UNDERLAYMENT
2x WOOD FASCIA BOARD, FINISH TO
MATCH GLU-LAM DECKING
METAL STANDING SEAM ROOFING
PRE-FINISHED METAL EAVE TRIM
CONTINUOUS CLEAT WITH STAINLESS
STEEL FASTENERS SPACED AS
REQUIRED BY MANUFACTURER
3x6 TONGUE AND GROVE WD DECKING - SEE
STRUCTURAL
1/2" PROTECTION BOARD
STANDING SEAM CLIP, TYP
6" ALUMINUM GUTTER
PREFINISHED WHITE
DEBRIS SCREEN
3/
4"
1/
2"
TOP OF MASONRY
111'-4"
7"
METAL ROOF PANEL
UNDERLAYMENT
1/2" EXTERIOR GYP SHEATHING
RAKE CLOSURE TRIM PIECE FLASHING
BY METAL ROOF MANUFACTURER
2x WOOD FASCIA BOARD, FINISH TO
MATCH GLU-LAM DECKING
2" WD DECKING - SEE STRUCTURAL
1/
4"
2"
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTSOffice of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
BID DOCUMENTS
OF XXX
TECHNOLOGY:
IMEG
11044 RESERCH BLVD A-230
AUSTIN, TX 78759
309.786.5092
JAYSON STICKROD, PE
IRRIGATION:
EC DESIGN GROUP, LTD
400 5TH STREET
WEST DES MOINES, IA 50265
515.225.6365
GEOTECHNICAL:
TERRACON
7770 WEST NEW YORK ST.
INDIANAPOLIS, IN 46214
317.746.7925
RICHARD D. OLSON, PE
COST ESTIMATING:
CPMI
1001 GRAND AVE, SUITE 201
WEST DES MOINES, IA 50265
515.244.1166
BRYAN BERTRANDERIK CHRISTIANSEN, ASIC
BUILDING 1001
C U s e rs \p c h o i\ D o c u m e n ts
\1
P
IC
A d m in is tr a ti o n
R
Y e u n y o u n g .r v t
/2 /2
:3
:3
P
M
PIC ADMIN. BLDG - ROOF PLAN AND ROOF
DETAILS
MARION NATIONAL CEMETRY
NEW LAND EXPANSION
1700 E 38TH ST, MARION, IN 46953
817CM3023
OCTOBER 30, 2024 Checker Author17101
1001-AE112
1/8" = 1'-0"
ROOF PLAN
3" = 1'-0"
RIDGE DETAIL
3" = 1'-0"
ROOF JACK PENETRATION DETAIL
0 8' 16'4'
1 1/2" = 1'-0"
SECTION DETAIL @ ROOF EAVE
1 1/2" = 1'-0"5
ROOF DETAIL @ CANOPY EAVE EDGE
1 1/2" = 1'-0"6
RAKE DETAIL
OF 266112112 OF 266112
1ST FLOOR
100'-0"
TOP OF MASONRY
111'-4"
Grade 99'-0"
AE311
DOWNSPOUT SHOE
TYPICAL - SEE CIVIL
DRAWING FOR ADDITIONAL
NOTES AND INFORMATION
DOWNSPOUT
STANDING SEAM
METAL ROOF
BRICK
GUTTER
DOWNSPOUT
BCDEF AB.2
TOP OF PIER
108'-8"
AE312
1'-4" 14'-8" 14'-8" 14'-8" 1'-4"
EXPANSION JOINT, TYP
ARCHED ROWLOCK
BRICK, TYP
W1 W1 W1 W1 W1 W1
1ST FLOOR
100'-0"
TOP OF MASONRY
111'-4"
Grade 99'-0"
AE311
AE311
AE311
DOWNSPOUT SHOE
TYPICAL - SEE CIVIL
DRAWING FOR ADDITIONAL
NOTES AND INFORMATION
DOWNSPOUT
STANDING SEAM
METAL ROOF
BRICK
GUTTER
2' -0
8'
-0
1 2 3 41.2 1.8
CARD READER
4'-0"10'-0"5'-4"
1'-4" 21'-4" 22'-0" 20'-0" 20'-0" 1'-4"
2' -0
8'
-0
EXPANSION JOINT, TYP
ARCHED ROWLOCK
BRICK, TYP
ROWLOCK BRICK
L1
W1
W1
W1 W1 W1
L2
1ST FLOOR
100'-0"
TOP OF MASONRY
111'-4"
Grade 99'-0"
AE311
DOWNSPOUT SHOE
TYPICAL - SEE CIVIL
DRAWING FOR ADDITIONAL
NOTES AND INFORMATION
DOWNSPOUT
STANDING SEAM
METAL ROOF
GUTTER
BRICK
B C D E F
SF02
A B.2
TOP OF PIER
108'-8"
AE312
5'-4" 20'-0" 20'-0" 1'-4"
EXPANSION JOINT, TYP
ROWLOCK BRICK, TYP
1ST FLOOR
100'-0"
TOP OF MASONRY
111'-4"
Grade 99'-0"
AE311
AE311
AE312
DOWNSPOUT SHOE
TYPICAL - SEE CIVIL
DRAWING FOR ADDITIONAL
NOTES AND INFORMATION
DOWNSPOUT
GUTTER
STANDING SEAM
METAL ROOF
ARCHED ROWLOCK
BRICK, TYP
STONE SILL
BRICK
SF01
METAL PANEL -BEYOND
1.21.8
TOP OF PIER
108'-8"
1'-4" 16'-0" 16'-0" 16'-0" 18'-0" 17'-4" 1'-4"
EXPANSION JOINT, TYP
GLU-LAM BEAM - SEE STRUCT
STEEL COLUMN - SEE STRUCT
ROWLOCK BRICK, TYP
W1 W1 W1 W1 W1 W1 W1 W1
ELEVATION KEYED NOTES
NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN
EL1
EL2
EL3
EL4
EL5
EL6
EL7
EL8
EL9
EL10
EL11
EL12
EL13
EL14
EL15
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTSOffice of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
BID DOCUMENTS
OF XXX
TECHNOLOGY:
IMEG
11044 RESERCH BLVD A-230
AUSTIN, TX 78759
309.786.5092
JAYSON STICKROD, PE
IRRIGATION:
EC DESIGN GROUP, LTD
400 5TH STREET
WEST DES MOINES, IA 50265
515.225.6365
GEOTECHNICAL:
TERRACON
7770 WEST NEW YORK ST.
INDIANAPOLIS, IN 46214
317.746.7925
RICHARD D. OLSON, PE
COST ESTIMATING:
CPMI
1001 GRAND AVE, SUITE 201
WEST DES MOINES, IA 50265
515.244.1166
BRYAN BERTRANDERIK CHRISTIANSEN, ASIC
BUILDING 1001
C U s e rs \p c h o i\ D o c u m e n ts
\1
P
IC
A d m in is tr a ti o n
R
Y e u n y o u n g .r v t
/2 /2
:3
:3
P
M
PIC ADMIN. BLDG - EXTERIOR ELEVATIONS MARION NATIONAL CEMETRY
NEW LAND EXPANSION
1700 E 38TH ST, MARION, IN 46953
817CM3023
OCTOBER 30, 2024 LA Author17101
1001-AE201
1/8" = 1'-0"
EAST EXTERIOR ELEVATION
1/8" = 1'-0"
SOUTH EXTERIOR ELEVATION
1/8" = 1'-0"
WEST EXTERIOR ELEVATION
1/8" = 1'-0"
NORTH EXTERIOR ELEVATION
0 8' 16'4' 0 8' 16'4'
0 8' 16'4'0 8' 16'4'
OF 266113113 OF 266113
CASEWORK GENERAL NOTES
1. FULL HEIGHT STORAGE CABINETS (UNO)
- SHALL BE 2'-0" DEEP
- 2'-0" MAX DOOR WIDTH
- WARDROBE CABINETS TO BE 2'-0" DEEP
- PROVIDE (5) FIVE ADJ PLAM SHELVES
2. BASE AND WALL CABINETS (UNO)
- WALL CABINETS 1'-0" DEEP CLEAR INSIDE MINIMUM
- BASE CABINETS 2'-0" DEEP
- (1) ADJ PLAM SHELF AT 2'-0" HIGH WALL CABINETS
- (2) ADJ PLAM SHELVES AT 2'-6" HIGH WALL CABINETS, AND
- (3) ADJ PLAM SHELVES AT 3'-0" HIGH WALL CABINETS
3. SEE INTERIOR ELEVATIONS FOR PLAM FILLERS AND SLOPED TOPS.
4. WHERE FILLER STRIPS ARE REQUIRED, THEY SHALL BE EQUAL IN SIZE AT BOTH
ENDS OF CASEWORK (UNO).
5. PROVIDE LOCKS ON INDIVIDUAL DOORS AND DRAWERS WHERE INDICATED.
6. PROVIDE CONTINUOUS SEALANT AT TOP OF BACKSPLASH/SIDESPLASHES.
7. PROVIDE 1" THICK SHELVES WHERE CABINETS ARE OVER 3'-0" WIDE.
8. PROVIDE GROMMETS AT WORKSTATIONS, INCLUDING NURSE STATIONS, RECEPTION
DESKS AND OTHER WORK COUNTERS. CUT IN FIELD-PROVIDE ONE PER ELECTRICAL
DEVICE BELOW COUNTER-COORDINATE LOCATIONS WITH OWNER. COLOR TO BE
SELECTED BY ARCHITECT. SEE SPECIFICATION FOR GROMMET TYPES AND SIZES.
9. PROVIDE A 2" RADIUSED EDGE (IN PLAN) AT ALL OUTSIDE, EXPOSED COUNTERTOP
CORNERS (UNO). ALL PLAM COUNTERTOPS SHALL HAVE A 1 1/4" THICK PLAM SQUARE
EDGE NOSING (UNO)
10. ALL COUNTERTOPS ARE 2'-1" DEEP (UNO)
11. PROVIDE PLYWOOD BACKING AT ALL SOLID SURFACE COUNTERTOPS.
12. COUNTERTOP SUPPORT BRACKETS ARE PROVIDED BY THE CASEWORK SUPPLIER.
PROVIDE WALL BLOCKING AT EACH SUPPORT. SPACE AT 3'-0" OC MAX.
13. COORDINATE LOCATION OF ALL UNDERCOUNTER SUPPORT WITH OWNER
FURNISHED/OWNER INSTALLED EQUIPMENT.
14. NO EXPOSED FASTENERS ON CASEWORK (UNO)
15. ALL EXPOSED METAL CLIP ANGLES AND BRACKETS TO BE PAINTED TO MATCH
CASEWORK.
16. ALL EXPOSED AND SEMI-EXPOSED SURFACES OF CASEWORK, SHELVING, BASE,
FULL HEIGHT AND UPPER WALL CABINETS, AND FINISHED END PANELS ARE PLAM
(UNO)
17. FIELD VERIFY SPACE AVAILABLE AT CABINET LOCATIONS PRIOR TO CASEWORK
FABRICATION.
18. RETURN BACKSPLASH AT SIDEWALLS (UNO).
19. TUCK WALL COVERING BEHIND ALL BACKSPLASHES.
20. ALL CABINETS TO RECEIVE BASE SCHEDULED FOR ROOM (UNO).
21. COORDINATE ALL SWITCHES, UNDER-CABINET LIGHT FIXTURES AND
UNDERCOUNTER RECEPTACLES WITH THE ELECTRICAL CONTRACTOR.
22. PROVIDE HANGING FILE EDGE/HARDWARE WHERE FILE DRAWERS ARE INDICATED
23. PROVIDE A 1/4" GAP BETWEEN BOTTOM EDGE OF COUNTERTOP AND TOP EDGE OF
DOOR FRONTS/DOORS OF CABINETS
24. REFER TO FINISH PLAN GENERAL NOTES FOR CASEWORK FINISHES (UNO)
25. BASE AS SCHEDULED (UNO)
26. PLAM COUNTERTOPS TO RECEIVE 3mm FLAT PVC EDGE (UNO).
27. NUMBERS SHOWN BELOW BASE CABINETS AND ABOVE WALL CABINETS REFER TO
NOMINAL WIDTH DIMENSIONS, IN INCHES, FOR THAT CABINET. SEE REFERENCE
DETAILS FOR ADDITIONAL INFORMATION.
28. ALL CASEWORK TO BE PLAM-1 (UNO)
CASEWORK ELEVATION REFERENCE DIAGRAM
WALL HUNG CABINETS
OPEN FILE
EQFILE
EQ
EQ
EQ6"
EQ
EQ
243015 24211836
ACCESSIBLE
SINK
36 36 24 27 42
MICRO (NIC)
SD
PTD
4" T
O E
S P
A C
E A
T
D
E E
P U
N O
S E
E E
LE
V
A T
IO
N
S
30 36
OPEN
S E
E E
LE
V
A T
IO
N
S
BASE CABINETS
4" BACKSPLASH TO MATCH
COUNTERTOP
SIDESPLASH WHEN REQUIRED
ADJUSTABLE SHELVES (UNO)
ACCESSIBLE SINK
OPEN BASE SHELVING CABINET. SEE
ELEVATION FOR NUMBER OF
SHELVES
SINK CABINET WITH HINGED DOOR
LOCK
S E
E E
LE
V
A T
IO
N
S
S P
A C
E U
N O
4" T
O E
E
LE
V S
E E
BASE CABINET WITH HINGED DOORS
BASE UNIT WIDTH
FILE CABINET (2) DRAWERS
DRAWER FRONT HEIGHT INFORMATION
DRAWER CABINET UNIT. SEE ELEVATIONS FOR NUMBER
OF DRAWERS
APRON WITH COUNTERTOP
OPEN DRAWER WITH COUNTERTOP
OPEN COUNTERTOP
CABINET UNIT WITH - SEE ELEVATIONS
AT GYP BD SOFFITS: 1" OVERHANG FROM CABINET AT
SIDE AND FRONT OF CABINET
AT PLAM SOFFITS: NO OVERHANG. SOFFITS ARE FLUSH
WITH SIDE AND FRONT OF CABINET DOORS
INDICATES REQUIRED CLEAR SPACE FOR VALANCE
- SEE ELEVATIONS
CABINET WITH HINGED DOORS AND VALANCE
CABINET WITH HINGED DOORS
OPEN CABINET WITH ADJUSTABLE SHELVES
H E
IG
H
T
C A
B
IN
E T
T Y
P
IC
A L
1" S
C R
IB
E
/ FILLER PANEL
1"MIN SCRIBE
CABINET WITH HINGED DOORS
AND MAIL SLOTS
CABINET WITH HINGED DOORS AND
OPEN MICROWAVE SHELF. 18"
CABINET SHELF DEPTH, VERIFY
WITH EQUIPMENT SCHEDULE
SOILED LINEN
CABINET
FULL HEIGHT STORAGE WITH (5)
ADJUSTABLE SHELVES (UNO)
FIXED CENTER SHELF AT
FULL HEIGHT CABINETS
CABINET UNIT
WIDTH
30" 30" 30" 30" 30" 33" 33"
30"30"30"30"30"
F2550
2' -1
0" 2'
-4
2' -0
AE550
AE550
AE550PLAM-2 COUNTERTOP
18'-0"
1" 12'-6" 5'-6"
PAINT SOFFIT P-3
7' -2
PLAM-1 CASEWORK
RB-1
36"30" 27"
27"30"30"30"
K4665
1' -4
27"
21" 21"
15"
2' -0
2'
-4
2' -1
0"
AE550
AE550
AE550
AE550
TRASHREC
K1552
AE550
R7250
7' -2
7' -2
13'-4" 3'-0 7/8"
1"
3'-0 7/8"4'-9"5'-0"3'-6"1"
CT-1
S-1 COUNTERTOP
W/BACK SPLASH
PAINT SOFFIT P-3
16'-4 7/8"
PLAM-1 CASEWORK
RB-1
A5075
A5082
A5109C
AE550
S-1 COUNTERTOP
W/BACK AND LEFT
SIDE SPLASH
2' -1
0"
SEE
FOR TYPICAL TILE LAYOUT
/1 AF600
A1066
SEE P301 DETAIL 8
FOR PIPE COVERING
P-2
6' -6
A5200
A5109D
SEE
FOR TYPICAL TILE LAYOUT
/1 AF600
6' -6
P-2
2' -1
0"
A5082
A5075A5109C
AE550
S-1 COUNTERTOP
W/BACK AND RIGHT
SIDE SPLASH
SEE
FOR TYPICAL TILE LAYOUT
/1 AF600
A1066
F2010
INSULATE EXPOSED PIPES,
SEE PLUMBING FOR DETAILS
P-2
6' -6
A5090
A5200
A5109D
SEE
FOR TYPICAL TILE LAYOUT
/1 AF600
P-2
6' -6
A5109D
A5090
A5200
SEE
FOR TYPICAL TILE LAYOUT
/1 AF600
6' -6
P-2
A5109C
AE550
S-1 COUNTERTOP
W/BACK AND SIDE SPLASH
SEE
FOR TYPICAL TILE LAYOUT
/1 AF600
A1066 A1066
INSULATE EXPOSED PIPES,
SEE PLUMBING FOR DETAILS
P-2
6' -6
2' -1
0"
A5109C
AE550
S-1 COUNTERTOP
W/BACK AND SIDE SPLASH
SEE
FOR TYPICAL TILE LAYOUT
/1 AF600
A1066 A1066
INSULATE EXPOSED PIPES,
SEE PLUMBING FOR DETAILS
6' -6
P-2
2' -1
0"
A5109D
A5200
/1 AF600SEE
FOR TYPICAL TILE LAYOUT
6' -6
P-2
AE550
3' -8
8"
2' -1
0"
FEC
S-1 COUNTERTOP
PT-1 COVE BASE
1'-3" 2'-6" 1'-3"
30" 30" 30" 30"
AE550
PLAM-2 COUNTERTOP
EQ. 10'-2" EQ.
PLAM-1 BASE CABINET
1" 10'-0" 1"
RB-1
VWC-2
7' -2
EWC, SEE PLUMBING
FOR DETAILS
PT-1 COVE BASE
P-3
AE211
AE2116
MEN'S
TOILET
WOMEN'S
TOILET
JANITOR
1' -5
/8
3'
-6
1' -7
3'
-1
1' -6
'-1
/8
7.
8.
6.
5'-10 7/8" 8'-0" 5'-10 1/8"
3'-11 7/8"
3'-11 7/8" 6'-4"
8'-7 7/8" 1'-8" 9'-5 1/8"
1' -6
3'
-1
1' -7
3'
-6
1' -5
/8
6' -0
5'-0"
1' -6
3'
-0
1' -6
MULTI
PURPOSE
ROOM
3' -0
CL
CL
CL
CL
CL
CL
3' -0
CL
CL
CL
CL
5'-5" 4'-0 1/8"
MOP SINK
EWC
3'-0"
EQ EQCL
B3
B3
SB1
B6s
B6
B3
B6s
A3
A3
XP3 XN3
B6
A3
XP3
A3
B3
5' -5
/4
1 2
C
D
E
F
1.2 1.8
AE211
LOBBY
CL
CL
1'-1"
1'-6"
1' -0
B6s
1' -1
/8
1'
-0
"CL
FEC
CL
CL
B6p
1'-4"
1'-1"
1' -6
3'
-0
1' -6
CL
CL
AE211
AE211
MEN'S
TOILET
WOMEN'S
TOILET
HALLWAY110.1
111.1
F R
O M
F A
C E
O F
W A
LL
7' -2
1'
-6
7' -2
XP3
B3b
B3b
B3
B3
8" 1'-6" 1'-6 1/8"
XP3
1'-6"
CL
CL CL
B6bs
XN3
1'-6" 8" 1'-6" 1'-6 1/8"
CL
CL CL
E
F
IT CLOSET &
STORAGE
ELEC
CLOSET
MECHANICAL
ROOM
B3b
5 1/8"
CL
5 1/8"CL
2" 2" 5' -0
FRP-1
X0003
P-1
MOP SINK
PT-1
COVE BASE
4' -6
5' -0
FRP-1
X0002
P-1
MOP SINK PT-1
COVE BASE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTSOffice of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
BID DOCUMENTS
OF XXX
TECHNOLOGY:
IMEG
11044 RESERCH BLVD A-230
AUSTIN, TX 78759
309.786.5092
JAYSON STICKROD, PE
IRRIGATION:
EC DESIGN GROUP, LTD
400 5TH STREET
WEST DES MOINES, IA 50265
515.225.6365
GEOTECHNICAL:
TERRACON
7770 WEST NEW YORK ST.
INDIANAPOLIS, IN 46214
317.746.7925
RICHARD D. OLSON, PE
COST ESTIMATING:
CPMI
1001 GRAND AVE, SUITE 201
WEST DES MOINES, IA 50265
515.244.1166
BRYAN BERTRANDERIK CHRISTIANSEN, ASIC
BUILDING 1001
C U s e rs \p c h o i\ D o c u m e n ts
\1
P
IC
A d m in is tr a ti o n
R
Y e u n y o u n g .r v t
/2 /2
:3
:3
P
M
PIC ADMIN. BLDG - ENLARGED PLANS AND
INTERIOR ELEVATIONS
MARION NATIONAL CEMETRY
NEW LAND EXPANSION
1700 E 38TH ST, MARION, IN 46953
817CM3023
OCTOBER 30, 2024 CZ CZ17101
1001-AE211
1/4" = 1'-0"
ELEVATION - WORK ROOM 107 - SOUTH
1/4" = 1'-0"
ELEVATION - BREAKROOM 108 - NORTH
1/4" = 1'-0"
ELEVATION - MEN'S TOILET 110 - SOUTH
1/4" = 1'-0"
ELEVATION - MEN'S
TOILET 110 - WEST
1/4" = 1'-0"
ELEVATION - WOMEN'S TOILET 111 - NORTH
1/4" = 1'-0"
ELEVATION - WOMEN'S
TOILET 111 - WEST
1/4" = 1'-0"
ELEVATION - WOMEN'S ROOM 116 - SOUTH
1/4" = 1'-0"6
ELEVATION - WOMEN'S ROOM 116 - WEST
1/4" = 1'-0"
ELEVATION - MEN'S ROOM 117 - EAST
1/4" = 1'-0"
ELEVATION - MEN'S ROOM 117 - SOUTH
1/4" = 1'-0"
ELEVATION - LOBBY 100 - EAST
1/4" = 1'-0"
ELEVATION - MULTI PURPOSE ROOM 115 - WEST
1/4" = 1'-0"
ELEVATION - LOBBY 100 - SOUTH
1/4" = 1'-0"1
ENLARGED PLAN - PUBLIC RESTROOMS
1/4" = 1'-0"2
ENLARGED PLAN - STAFF TOILET ROOMS
1/4" = 1'-0"7
ELEVATION - JANITOR 118 - EAST
1/4" = 1'-0"8
ELEVATION - JANITOR 118 - SOUTH
OF 266114114 OF 266114
TOP OF MASONRY
111'-4"
B C D E F
GENERAL
OFFICE
MULTI
PURPOSE
ROOM
B.2
1ST FLOOR
100'-0"
TOP OF MASONRY
111'-4"
AE312
1 2 3 41.2 1.8
190 SF
MEN'S
TOILET
JANITOR
WOMEN'S
TOILET
MULTI
PURPOSE
ROOM
MECHANICAL
ROOM
IT CLOSET &
STORAGE
HALLWAY
WORK
ROOM
1ST FLOOR
100'-0"
TOP OF MASONRY
111'-4"
AE312
B C D E FA
100A
VESTIBULE
LOBBY
JANITOR 117
MEN'S
TOILET
B.2
TOP OF PIER
108'-8"
AE312
AE312
1ST FLOOR
100'-0"
AE312
1 21.2 1.8
TOP OF PIER
108'-8"
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTSOffice of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
BID DOCUMENTS
OF XXX
TECHNOLOGY:
IMEG
11044 RESERCH BLVD A-230
AUSTIN, TX 78759
309.786.5092
JAYSON STICKROD, PE
IRRIGATION:
EC DESIGN GROUP, LTD
400 5TH STREET
WEST DES MOINES, IA 50265
515.225.6365
GEOTECHNICAL:
TERRACON
7770 WEST NEW YORK ST.
INDIANAPOLIS, IN 46214
317.746.7925
RICHARD D. OLSON, PE
COST ESTIMATING:
CPMI
1001 GRAND AVE, SUITE 201
WEST DES MOINES, IA 50265
515.244.1166
BRYAN BERTRANDERIK CHRISTIANSEN, ASIC
BUILDING 1001
C U s e rs \p c h o i\ D o c u m e n ts
\1
P
IC
A d m in is tr a ti o n
R
Y e u n y o u n g .r v t
/2 /2
:3
:4
P
M
PIC ADMIN. BLDG - BUILDING SECTIONS MARION NATIONAL CEMETRY
NEW LAND EXPANSION
1700 E 38TH ST, MARION, IN 46953
817CM3023
OCTOBER 30, 2024 LA Author17101
1001-AE301
1/4" = 1'-0"
BUILDING SECTION
1/4" = 1'-0"
BUILDING SECTION
1/4" = 1'-0"
BUILDING SECTION
0 4' 8'2'
0 4' 8'2' 0 4' 8'2'
1/4" = 1'-0"
BUILDING SECTION
0 4' 8'2'
OF 266115115 OF 266115
TOP OF MASONRY
111'-4"
Grade 99'-0"
6" ALUMINUM
GUTTER
PREFINISHED
WHITE
WOOD TRUSSES
ADJUSTABLE CAVITY WALL TIE
5/8" PLYWOOD EXT SHEATHING
3" RIGID
INSULATION
BRICK VENEER
WEEP VENTS
32" OC
STAINLESS STEEL FLASHING
W/ HEMMED DRIP
6" METAL STUDS
BATT INSULATION
5/8" GYP BD
FOUNDATION
SEE - STRUCTURAL
LANDSCAPE MULCH
MORTAR NET
SLUSHED CAVITY
AIR AND MOISTURE BARRIER
TERMINATION BAR
W/ CONTINUOUS SEALANT
AIR SPACE
WOOD FASCIA
STANDING SEAM
METAL ROOF
2'-0"
AE112
F
AE520
1ST FLOOR
100'-0"
TOP OF MASONRY
111'-4"
Grade 99'-0"
6" ALUMINUM
GUTTER
PREFINISHED
WHITE
WOOD TRUSSES
ADJUSTABLE CAVITY WALL TIE
5/8" PLYWOOD EXT SHEATHING
3" RIGID INSULATION
BRICK VENEER
WEEP VENTS 32" OC
STAINLESS STEEL FLASHING
W/ HEMMED DRIP
6" METAL
STUDS
BATT INSULATION
5/8" GYP BD
FOUNDATION
SEE - STRUCTURAL
LANDSCAPE MULCH
MORTAR NET
SLUSHED CAVITY
AIR AND MOISTURE BARRIER
TERMINATION BAR
W/ CONTINUOUS SEALANT
AIR SPACE
WOOD FASCIA
STANDING SEAM
METAL ROOF
2'-0"
F
5' -4
2'
-8
AE112
SOLID SURFACE
(S-1) SILL
AE520
AE520
AE520
1ST FLOOR
100'-0"
TOP OF MASONRY
111'-4"
6" ALUMINUM
GUTTER
PREFINISHED
WHITE
WOOD TRUSSES
ADJUSTABLE CAVITY WALL TIE
5/8" PLYWOOD EXT SHEATHING
BATT INSULATION
AIR AND MOISTURE BARRIER
DEBRIS SCREEN
WOOD FASCIA
STANDING SEAM
METAL ROOF
BATT INSULATION
R=40
2'-0"
F
CONCRETE STOOP - SEE STRUCT
CONCRETE SIDEWALK - SEE
130 SF
HALLWAY
LIGHTING FIXTURE
AE520
REV
AE520
REV
1ST FLOOR
100'-0"
TOP OF MASONRY
111'-4"
Grade 99'-0"
3" RIGID INSULATION
BRICK VENEER
WEEP VENTS 32" OC
STAINLESS STEEL FLASHING
W/ HEMMED DRIP
6" METAL
STUDS
5/8" GYP BD
FOUNDATION
SEE - STRUCTURAL
LANDSCAPE MULCH
MORTAR NET
SLUSHED CAVITY
TERMINATION BAR
W/ CONTINUOUS SEALANT
AIR SPACE
6" ALUMINUM
GUTTER
PREFINISHED
WHITE
WOOD TRUSSES
DEBRIS SCREEN
WOOD FASCIA
STANDING SEAM
METAL ROOF
BATT INSULATION
R=40
SOLDIER COURSE BRICK
1' -4
6'
-0
2' -8
AE520
AE520
SIM
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTSOffice of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
BID DOCUMENTS
OF XXX
TECHNOLOGY:
IMEG
11044 RESERCH BLVD A-230
AUSTIN, TX 78759
309.786.5092
JAYSON STICKROD, PE
IRRIGATION:
EC DESIGN GROUP, LTD
400 5TH STREET
WEST DES MOINES, IA 50265
515.225.6365
GEOTECHNICAL:
TERRACON
7770 WEST NEW YORK ST.
INDIANAPOLIS, IN 46214
317.746.7925
RICHARD D. OLSON, PE
COST ESTIMATING:
CPMI
1001 GRAND AVE, SUITE 201
WEST DES MOINES, IA 50265
515.244.1166
BRYAN BERTRANDERIK CHRISTIANSEN, ASIC
BUILDING 1001
C U s e rs \p c h o i\ D o c u m e n ts
\1
P
IC
A d m in is tr a ti o n
R
Y e u n y o u n g .r v t
/2 /2
:3
:4
P
M
PIC ADMIN. BLDG - WALL SECTIONS MARION NATIONAL CEMETRY
NEW LAND EXPANSION
1700 E 38TH ST, MARION, IN 46953
817CM3023
OCTOBER 30, 2024 LA JT17101
1001-AE311
3/4" = 1'-0"
WALL SECTION
XX
3/4" = 1'-0"
WALL SECTION AT WINDOW
3/4" = 1'-0"
WALL SECTION AT MAN DOOR
3/4" = 1'-0"
WALL SECTION AT ENTRY STOREFRONT
0 1'-4" 2'-8"8" 0 1'-4" 2'-8"8" 0 1'-4" 2'-8"8" 0 1'-4" 2'-8"8"
OF 266116116 OF 266116
TOP OF MASONRY
111'-4"
B
CONCRETE STOOP - SEE STRUCT
CONCRETE SIDEWALK - SEE
A B.2
TOP OF PIER
108'-8"
AE312
119 SF
100A
VESTIBULE
ADJUSTABLE CAVITY WALL TIE
5/8" PLYWOOD EXT SHEATHING
3" RIGID
INSULATION
BRICK
6" METAL STUDS
5/8" GYP BD
AIR AND MOISTURE BARRIER
AIR SPACE
BRICK PIER BEYOND
STEEL COLUMN BEYOND - SEE STRUCT
GLU-LAM BEAM - SEE STRUCT
BRICK SOLDER COURSE
METAL PANEL
AE520
AE520
SIM
1ST FLOOR
100'-0"
TOP OF MASONRY
111'-4"
21.8
TOP OF PIER
108'-8"
AE112
FOOTING AND FOUNDATION,
SEE STRUCTURAL DRAWINGS
BRICK
CAST IN PLACE
CONCRETE COLUMN,
SEE STRUCTURAL
DRAWINGS
HSS COLUMN, PAINT
- SEE STRUCTURAL
DRAWINGS
BASE PLATE AND
GROUT - SEE
STRUCTURAL DRAWINGS
2' -8
7"
3'-0"
'-4
GLU-LAM BEAM
- SEE STRUCTURAL
DRAWINGS
6" ALUMINUM
GUTTER
PREFINISHED
WHITE
STANDING SEAM
METAL ROOF
1ST FLOOR
100'-0"
TOP OF MASONRY
111'-4"
TOP OF PIER
108'-8"
274 SF
LOBBY
119 SF
100A
VESTIBULE
CARD READER
1/
2" 8'
-2
/2
LIGHTING FIXTURE
ACT CEILING
B3
ALUMINUM
STOREFRONT
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTSOffice of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
BID DOCUMENTS
OF XXX
TECHNOLOGY:
IMEG
11044 RESERCH BLVD A-230
AUSTIN, TX 78759
309.786.5092
JAYSON STICKROD, PE
IRRIGATION:
EC DESIGN GROUP, LTD
400 5TH STREET
WEST DES MOINES, IA 50265
515.225.6365
GEOTECHNICAL:
TERRACON
7770 WEST NEW YORK ST.
INDIANAPOLIS, IN 46214
317.746.7925
RICHARD D. OLSON, PE
COST ESTIMATING:
CPMI
1001 GRAND AVE, SUITE 201
WEST DES MOINES, IA 50265
515.244.1166
BRYAN BERTRANDERIK CHRISTIANSEN, ASIC
BUILDING 1001
C U s e rs \p c h o i\ D o c u m e n ts
\1
P
IC
A d m in is tr a ti o n
R
Y e u n y o u n g .r v t
/2 /2
:3
:4
P
M
PIC ADMIN. BLDG - WALL SECTIONS MARION NATIONAL CEMETRY
NEW LAND EXPANSION
1700 E 38TH ST, MARION, IN 46953
817CM3023
OCTOBER 30, 2024 LA JT17101
1001-AE312
3/4" = 1'-0"
WALL SECTION AT ENTRY
0 1'-4" 2'-8"8" 3/4" = 1'-0"
WALL SECTION AT ENTRY CANOPY/PIER
0 1'-4" 2'-8"8"
Revisions: Date:
3/4" = 1'-0"
WALL SECTION AT LOBBY
OF 266117117 OF 266117
SEE WALL SECTIONS AND WALL
TYPES FOR WALL CONSTRUCTION
FLUID-APPLIED MEMBRANE AIR BARRIER
TERMINATION BAR
CONNECTION FROM WINDOW TO
SUPPORTING STRUCTURE
SEALANT
PRIMARY SEAL
ELASTOMERIC SHEETING MUST
EXTEND BACK TO PRIMARY SEAL
ALUMINUM WINDOW
3" RIGID INSULATION
LINE INDICATES WALL BELOW
BACKER ROD AND SEALANT
BACKER ROD AND SEALANT
4" 2 1/2"
6" COLD FORMED STEEL BOX
BEAM. - SEE STRUCTURAL
SOLID SURFACE SILL BELOW
GRID
NOTE:
PROVIDE EXPANSION JOINT AT
ALL OUTSIDE CORNERS,
SEE EXTERIOR ELEVATION FOR
LOCATION
3/8" EXPANSION JOINT
3/8" EXPANSION JOINT
AE501
COMPRESSIBLE JOINT FILLER
3/8" THICK X DEPTH OF
MASONRY (LESS 1")
NOTE: KEEP JOINT
FREE OF MORTAR
SEALANT AND BACKER ROD
3/8" EXPANSION JOINT
AE501
BACKER ROD AND
SEALANT -BOTH SIDES
3" DEEP SPRAY FOAM
INSULATION
SEE WALL SECTION AND WALL
TYPES FOR WALL CONSTRUCTION
BUILDING MEMBRANE
TERMINATION BAR
MEMBRANE FLASHING
12 GA GALV BENT PLATE WITH 4"
LONG VERTICAL LEG AND
HORIZONTAL LEG TO ALIGN WITH
PLATE EDGE AT HEAD CONDITION
FILL FRAME WITH SPRAY FOAM
HM FRAME AND INSUL HM DOOR
M
IN4"
SEALANT
F
2"
5 3/4" AT 108.1
8 3/4" AT 112.1
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTSOffice of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
BID DOCUMENTS
OF XXX
TECHNOLOGY:
IMEG
11044 RESERCH BLVD A-230
AUSTIN, TX 78759
309.786.5092
JAYSON STICKROD, PE
IRRIGATION:
EC DESIGN GROUP, LTD
400 5TH STREET
WEST DES MOINES, IA 50265
515.225.6365
GEOTECHNICAL:
TERRACON
7770 WEST NEW YORK ST.
INDIANAPOLIS, IN 46214
317.746.7925
RICHARD D. OLSON, PE
COST ESTIMATING:
CPMI
1001 GRAND AVE, SUITE 201
WEST DES MOINES, IA 50265
515.244.1166
BRYAN BERTRANDERIK CHRISTIANSEN, ASIC
BUILDING 1001
C U s e rs \p c h o i\ D o c u m e n ts
\1
P
IC
A d m in is tr a ti o n
R
Y e u n y o u n g .r v t
/2 /2
:3
:4
P
M
PIC ADMIN. BLDG - EXTERIOR PLAN DETAILS MARION NATIONAL CEMETRY
NEW LAND EXPANSION
1700 E 38TH ST, MARION, IN 46953
817CM3023
OCTOBER 30, 2024 Checker Author17101
1001-AE501
1 1/2" = 1'-0"1
PLAN DETAIL - WINDOW JAMB
3" = 1'-0"3
PLAN DETAIL - FACE BRICK EXPANSION JOINT AT OUTSIDE CORNER
12" = 1'-0"5
PLAN DETAIL - EXPANSION JOINT
3" = 1'-0"4
PLAN DETAIL - TYPICAL EXPANSION JOINT
Revisions: Date:
1 1/2" = 1'-0"2
PLAN DETAIL - HM FRAME JAMB AT METAL STUD BACK
UP AND FACE BRICK
OF 266118118 OF 266118
WINDOW HEAD
MO ELEVATION
8" M
IN
4"
M
IN
GALV BREAK METAL
FLASHING
GALVANIZED STEEL LINTEL 3 1/2"x3 1/2"x1/4". -SEE STRUCTURAL
LOUVERED WEEPS AT 16"
ON CENTER
THROUGH WALL STAINLESS
STEEL FLASHING WITH DRIP
BACKER ROD AND
SEALANT
SEE WALL SECTION AND WALL TYPES
FOR WALL CONSTRUCTION
CAVITY DRAIN MATERIAL
TERMINATION BAR
ELASTOMERIC SHEETING-SEAL VAPOR
TIGHT TO TOP OF MET FLASHING
FLUID-APPLIED MEMBRANE AIR BARRIER
CLIP ATTACHED MINERAL WOOL
CONNECTION FROM WINDOW
TO SUPPORTING STRUCTURE
ALUMINUM WINDOW
GALV BREAK METAL CLOSURE
TRIM
PRIMARY SEAL
1/4" ROD AND SEALANT JOINT
SEALANT
STEEL BOX BEAM. - SEE STRUCTURAL
GRID
2 1/2" 4"
SEE WALL SECTION AND WALL TYPES
FOR WALL CONSTRUCTION
PRECAST CONCRETE SILL
ROD AND SEALANT WITH
WEEPS AT 16" OC-TYP
PREFINISHED ALUM FLASH TO MATCH
WINDOW MULLION W/ CONT SEALANT
TO PRECAST SILL
1/4" ROD AND SEALANT JOINT
SOLID SURFACE (S-X) SILL
3" DEEP SPRAY FOAM
INSULATION
GRID
ELASTOMERIC SHEETING SEAL
VAPOR TIGHT TO STEEL ANGLE.
EXTEND UP OVER STEEL PLATE AND
EXTEND BACK TO PRIMARY SEAL
PRIMARY SEAL
ALUMINUM WINDOW
STEEL ANGLE CONNECTION
FROM WINDOW TO
SUPPORTING STRUCTURE
COLD FORMED STEEL STUD BOX
BEAM - SEE STRUCTURAL
CONNECTION FROM WINDOW TO
SUPPORTING STRUCTURE
1/
2"
2 1/2" 4"
GRID
FIRST LEVEL
0'-0"
CONCRETE SLAB ON GRADE -SEE STRUCTURAL
SEE WALL SECTION AND WALL TYPES
FOR WALL CONSTRUCTION
FILL SOLID WITH GROUT
STAINLESS STEEL THOUGH WALL FLASHING
WITH DRIP
SEALANT
ELASTOMERIC SHEETING TO TERMINATION
BAR ABOVE
LOUVERED WEEP HOLES AT 16" ON CENTER
CAVITY DRAIN MATERIAL
TERMINATION BAR
SEALANT
FLUID APPLIED MEMBRANE AIR
BARRIER
SLOPE GRADE AWAY FROM BUILDING - SEE
CIVIL FOR ADDITIONAL INFORMATION
2" CONTINUOUS PERIMETER INSULATION
DOWN TO BOTTOM OF GRADE BEAM / PILE CAP
12 GA BENT PLATE -SEE STRUCTURAL
8"
ALUMINUM DOOR AND FRAME
FACE OF BRICK WALL
BEYOND
FIRST LEVEL
0'-0"
EXISTING FOUNDATION WALL
CONSTRUCTION. FIELD VERIFY
LOCATION AND COMPOSITION
CONCRETE SLAB ON GRADE -SEE STRUCTURAL
METAL THRESHOLD SET IN SEALANT BED
EXISTING CONCRETE SLAB
CONSTRUCTION. FIELD VERIFY
LOCATION AND COMPOSITION
WALL BEYOND. SEE PLANS
VAPOR BARRIER. TURN DOWN FACE OF EXISTING WALL
4" MIN
ENGINEERED FILL - SEE STRUCTURAL
GRANULAR FILL - SEE STRUCTURAL
2" RIGID INSULATION. EXTEND 2'-0" HORIZONTAL AT
EXTERIOR WALL
2" RIGID INSULATION. EXTEND DOWN 2'-0" VERTICALLY
AT EXTERIOR WALL
3" 4 1/2"
B
SEE WALL SECTIONS AND WALL TYPES
FOR WALL CONSTRUCTION
SPRAY FOAM INSULATION
STEEL ANGLE -SEE STRUCTURAL
ALUMINUM FLASHING WITH DRIP
FILL FRAME WITH SPRAY FOAM
ROWLOCK BRICK
HOLLOW METAL DOOR AND FRAME
SHIM AS REQUIRED
5 3/4" 2"
BUILDING MEMBRANE
F
ALUMINUM DOOR AND FRAME
FACE OF BRICK WALL
BEYOND
FIRST LEVEL
0'-0"
EXISTING FOUNDATION WALL
CONSTRUCTION. FIELD VERIFY
LOCATION AND COMPOSITION
CONCRETE SLAB ON GRADE -SEE STRUCTURAL
METAL THRESHOLD SET IN SEALANT BED
EXISTING CONCRETE SLAB
CONSTRUCTION. FIELD VERIFY
LOCATION AND COMPOSITION
WALL BEYOND. SEE PLANS
VAPOR BARRIER. TURN DOWN FACE OF EXISTING WALL
4" MIN
ENGINEERED FILL - SEE STRUCTURAL
GRANULAR FILL - SEE STRUCTURAL
2" RIGID INSULATION. EXTEND 2'-0" HORIZONTAL AT
EXTERIOR WALL
2" RIGID INSULATION. EXTEND DOWN 2'-0" VERTICALLY
AT EXTERIOR WALL
2" 5 3/4"
DOOE FRAME BEYOND
F
LOUVER HEAD
GALV BREAK
METAL FLASHING
LINTEL-SEE
STRUCTURAL
VERTICAL JOINTS
WEEP VENTS
ALUMINUM FLASHING WITH DRIP
BACKER ROD AND
SEALANT -BOTH SIDES
SEE WALL SECTION AND WALL
TYPES FOR WALL
CONSTRUCTION
MORTAR TRAP
TERMINATION BAR
MEMBRANE FLASHING-
SEAL VAPOR TIGHT TO
TOP OF MET FLASHING
BUILDING MEMBRANE
CLIP ATTACHED MINERAL WOOL
12 GAUGE GALVANIZED STEEL PLATE
ALUMINUM LOUVER
GALV BREAK METAL
CLOSURE TRIM
SHIM AS REQUIRED
MO ELEVATION
F
6" STEEL STUD
LOUVER SILL
12 GAUGE GALVANIZED
STEEL PLATE TO ALIGN WITH
SILL MASONRY OPENING
SEE WALL SECTIONS AND WALL TYPES
FOR WALL CONSTRUCTION
ALUMINUM FLASHING WITH DRIP
SEALANT
BACKER ROD AND SEALANT.
PRIMARY SEAL
4" DEEP SPRAY FOAM INSULATION
ALUMINUM LOUVER
BACKER ROD AND SEALANT
STEEL ANGLE -
SEE STRUCTURAL
MEMBRANE FLASHING SEAL
VAPOR TIGHT TO STEEL
ANGLE. EXTEND UP OVER
GALV. PLATE AND EXTEND
BACK TO PRIMARY SEAL
MO ELEVATION
6" STEEL STUD
BUILDING MEMBRANE
SHIM AS REQUIRED
F
LOUVER SILL
12 GAUGE GALVANIZED
STEEL PLATE TO ALIGN WITH
SILL MASONRY OPENING
SEE WALL SECTIONS AND WALL TYPES
FOR WALL CONSTRUCTION
ALUMINUM FLASHING WITH DRIP
SEALANT
BACKER ROD AND SEALANT.
PRIMARY SEAL
SPRAY FOAM INSULATION
ALUMINUM LOUVER
BACKER ROD AND SEALANT
STEEL ANGLE -SEE STRUCTURAL
MEMBRANE FLASHING SEAL
VAPOR TIGHT TO STEEL
ANGLE. EXTEND UP OVER
GALV. PLATE AND EXTEND
BACK TO PRIMARY SEAL
MO ELEVATION
6" STEEL STUD ALUMINUM FLASHING WITH DRIP
8" STEEL STUD
FILL FRAME WITH SPRAY FOAM
ROWLOCK BRICK
HOLLOW METAL DOOR AND FRAME
BUILDING MEMBRANE
8 3/4" 2"
SHIM AS REQUIRED
F
WINDOW HEAD
MO ELEVATION
8" M
IN
4"
M
IN
GALV BREAK METAL
FLASHING
GALVANIZED STEEL LINTEL 3 1/2"x3 1/2"x1/4". -SEE STRUCTURAL
LOUVERED WEEPS AT 16"
ON CENTER
THROUGH WALL STAINLESS
STEEL FLASHING WITH DRIP
BACKER ROD AND
SEALANT
SEE WALL SECTION AND WALL TYPES
FOR WALL CONSTRUCTION
CAVITY DRAIN MATERIAL
TERMINATION BAR
ELASTOMERIC SHEETING-SEAL VAPOR
TIGHT TO TOP OF MET FLASHING
FLUID-APPLIED MEMBRANE AIR BARRIER
CLIP ATTACHED MINERAL WOOL
CONNECTION FROM WINDOW
TO SUPPORTING STRUCTURE
ALUMINUM
STOREFRONT
GALV BREAK METAL CLOSURE
TRIM
PRIMARY SEAL
1/4" ROD AND SEALANT JOINT
SEALANT
STEEL BOX BEAM. - SEE STRUCTURAL
GRID
ALUMINUM TRIM
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTSOffice of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
BID DOCUMENTS
OF XXX
TECHNOLOGY:
IMEG
11044 RESERCH BLVD A-230
AUSTIN, TX 78759
309.786.5092
JAYSON STICKROD, PE
IRRIGATION:
EC DESIGN GROUP, LTD
400 5TH STREET
WEST DES MOINES, IA 50265
515.225.6365
GEOTECHNICAL:
TERRACON
7770 WEST NEW YORK ST.
INDIANAPOLIS, IN 46214
317.746.7925
RICHARD D. OLSON, PE
COST ESTIMATING:
CPMI
1001 GRAND AVE, SUITE 201
WEST DES MOINES, IA 50265
515.244.1166
BRYAN BERTRANDERIK CHRISTIANSEN, ASIC
BUILDING 1001
C U s e rs \p c h o i\ D o c u m e n ts
\1
P
IC
A d m in is tr a ti o n
R
Y e u n y o u n g .r v t
/2 /2
:3
:4
P
M
PIC ADMIN. BLDG - EXTERIOR SECTION
DETAILS
MARION NATIONAL CEMETRY
NEW LAND EXPANSION
1700 E 38TH ST, MARION, IN 46953
817CM3023
OCTOBER 30, 2024 LA PC, JT17101
1001-AE520
1 1/2" = 1'-0"
SECTION DETAIL - WINDOW HEAD
1 1/2" = 1'-0"
SECTION DETAIL - WINDOW SILL
1 1/2" = 1'-0"
SECTION DETAIL - BRICK EDGE AND FOUNDATION
1 1/2" = 1'-0"
SECTION DETAIL - DOOR SILL @ CANOPY
Revisions: Date:
1 1/2" = 1'-0"
SECTION DETAIL - DOOR HEAD @ ROWLOCK BRICK
1 1/2" = 1'-0"
SECTION DETAIL - DOOR SILL @ EXTERIOR
1 1/2" = 1'-0"
SECTION DETAIL - LOUVER HEAD @ BRICK
1 1/2" = 1'-0"
SECTION DETAIL - LOUVER SILL@ BRICK
1 1/2" = 1'-0"
SECTION DETAIL - LOUVER SILL@ ROWLOCK BRICK
1 1/2" = 1'-0"
SECTION DETAIL - STOREFRONT HEAD
OF 266119119 OF 266119
S
E
IN
T E
R
IO
R E
LE
V
A T
IO
N
S
7' -2
U
N O
BOTTOM OF
SOFFIT TYP
ADJUSTABLE SHELVES-
SEE INTERIOR
ELEVATIONS FOR
QUANTITY
AE550
4"
3"
2'-0" UNO
SEE ELEVATIONS FOR
SOFFIT/FASCIA TYPE
BASE AS SCHEDULED
1/
4"
BOTTOM OF
SOFFIT, TYP
7' -2
A
F F
U .N
.O
S E
E
IN
T E
R
IO
R E
LE
V
A T
IO
N
S
AE550
1'-0" CLEAR
S E
E E
LE
V
A T
IO
N
S
SOFFIT AS OCCURS -SEE
INTERIOR ELEVATIONS.
ADJUSTABLE SHELVES, SEE INTERIOR
ELEVATIONS FOR QTY.
1"
6"
PULL-OUT SHELF, WHERE
INDICATED. REFER TO
ELEVATION
ADJUSTABLE SHELF
DRAWER UNIT OR APRON,
WHERE INDICATED
3"
4"
S E
E E
LE
LV
A T
IO
N
S
2'-1" UNO.
SEE ELEVATIONS
BASE AS SCHEDULED
PULL-OUT SHELF FOR
TRASH CAN
3"
4"
S E
E E
LE
LV
A T
IO
N
S
2'-1" UNO.
BASE AS SCHEDULED
8" M
IN
DOOR ATTACHED TO
PULL OUT SHELF
TRASH
WALL BACKING
8" 3"
9"
M
IN
S E
E E
LE
V
A T
IO
N
S
2' -1
0" O
R
'-0
UNDERMOUNT SINK WITH OFFSET
DRAIN (ALLOW ROOM FOR
EQUIPMENT UNDER CABINET)
CLEAR WHEEL
CHAIR CLEARANCE
WHERE INDICATED PROVIDE
REMOVABLE 3/4" THICK PLAM OVER
MDF BOARD FASCIA PANEL.
CONTINUOUS, FULL LENGTH OF
VANITY - ADD REMOVABLE HARDWARE
M A
X
1/
2" 1"
1' -1
/4
2'-1" UNO
1'-7"
8"
1/
2"
3/4"
SOLID SURFACE COUNTERTOP W/ BACK AND SIDESPLASH
3/4" THICK PLAM APRON
WALL
BACKING
UNDERMOUNT SINK -SEE PLUMBING
DRAWINGS
FAUCET, SEE PLUMBING DRAWINGS.
SOLID SURFACE APRON
9" M
IN
CLEAR WHEEL
CHAIR CLEARANCE
6" MAX 3" 8" MIN
M
IN
PLYWOOD
S-1 COUNTERTOP WITH EASED EDGE
1'-9" OR 2'-1"
S-1 SOLID SURFACE BACKSPLASH
2' -1
0"
INSULATE
EXPOSED PIPES,
SEE PLUMBING
DRAWINGS.
3/4" PLAM SHELF
3/4" PLAM DOOR
3"
4"
S E
E E
LE
LV
A T
IO
N
S
2'-1"UNO.
BASE AS SCHEDULED
PULL
PROVIDE EDGE BANDING
ON ALL EXPOSED EDGES
1/4" PLAM FACED BACK
WALL
BACKING
1/
2" 1'
-0
/2
1' -3
1"
1ST FLOOR
100'-0"
DOUBLE METAL BOX
HEADER @ HEADER
WOOD BLOCKING
3/8" LAMINATE SAFETY
GLASS
COUNTERTOP, S-1
METAL CHANNEL W/
NEOPRENE GASKET
PLYWOOD
METAL CHANNEL W/
NEOPRENE GASKET
1"
"X"
FILLER CUT TO FIT TO
MATCH CABINET FACE
GYPSUM BOARD
HANGER WIRE
CEILING AS SCHEDULED
5/8" GYP BD ON 3 5/8"
METAL STUDS AT 24" OC
6" S
E E
R C
P
SEE RCP FOR DIMENSION
PULL-OUT SHELF,
WHERE INDICATED.
REFER TO ELEVATION
ADJUSTABLE
SHELVES
3"
4"
BASE AS SCHEDULED
1"
SEALANT AT WALLS
SUPPORT FRAME AS
REQUIRED
U N
O
4"
1/ 2"
S E
E
IN
T E
R
IO
R E
LE
V
A T
IO
N
S F
O R
C A
B
IN
T
H
IG
H T
SIDE & BACK SPLASH AS
INDICATED ON INTERIOR
ELEVATIONS
2'-1" UNO.
1"
TYPE CNTP-S1: SOLID SURFACE WITH
BACKSPLASH
PLAM
TYPE CNTP-P2: PLAM WITH PVC EDGE
NO BACKSPLASH
SOLID SURFACE
SET BACKSPLASH IN SEALANT
ON COUNTER
CONTINUOUS 2" x 2" x
1/8" ALUMINUM
SUPPORT ANGLE &
BLOCKING AT OPEN
BASE CABINET.
FACE OF CABINET
3MM PVC EDGE
SEALANT
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTSOffice of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
BID DOCUMENTS
OF XXX
TECHNOLOGY:
IMEG
11044 RESERCH BLVD A-230
AUSTIN, TX 78759
309.786.5092
JAYSON STICKROD, PE
IRRIGATION:
EC DESIGN GROUP, LTD
400 5TH STREET
WEST DES MOINES, IA 50265
515.225.6365
GEOTECHNICAL:
TERRACON
7770 WEST NEW YORK ST.
INDIANAPOLIS, IN 46214
317.746.7925
RICHARD D. OLSON, PE
COST ESTIMATING:
CPMI
1001 GRAND AVE, SUITE 201
WEST DES MOINES, IA 50265
515.244.1166
BRYAN BERTRANDERIK CHRISTIANSEN, ASIC
BUILDING 1001
C U s e rs \p c h o i\ D o c u m e n ts
\1
P
IC
A d m in is tr a ti o n
R
Y e u n y o u n g .r v t
/2 /2
:3
:4
P
M
PIC ADMIN. BLDG - INTERIOR SECTION
DETAILS
MARION NATIONAL CEMETRY
NEW LAND EXPANSION
1700 E 38TH ST, MARION, IN 46953
817CM3023
OCTOBER 30, 2024 CZ CZ17101
1001-AE550
1" = 1'-0"
TALL CABINET SINGLE DOOR
1" = 1'-0"9
WALL CABINET WITH DOOR
1" = 1'-0"
BASE CABINET DRAWER & DOOR
1" = 1'-0"
BASE CABINET - PULL OUT TRASH
1" = 1'-0"
CABINET WITH SINK AND APRON
1" = 1'-0"
LAVATORY TOP DETAIL
1" = 1'-0"
BASE CABINET WITH DOOR & OPEN SHELF
3/4" = 1'-0"
PASS THROUGH WINDOW LOWER COUNTERTOP
1 1/2" = 1'-0"10
SECTION AT CASEWORK SOFFIT/FASCIA TYPES
1" = 1'-0"
BASE CABINET
Revisions: Date:
1" = 1'-0"11
COUNTERTOP TYPES
OF 266120120 OF 266120
NO SUBSCRIPT
EXTEND ENTIRE
PARTITION TO
UNDERSIDE OF
STRUCTURE
FLOOR
CEILING
BOTTOM
OF FLOOR
OR DECK
(D) SUBSCRIPT
EXTEND STUDS TO
DECK, EXTEND
GYPSUM BOARD TO
6" ABOVE HIGHEST
ADJACENT CEILING
6"
(C) SUBSCRIPT
EXTEND ENTIRE
PARTITION TO 6"
ABOVE HIGHEST
ADJACENT
CEILING
6"
(U) SUBSCRIPT
EXTEND ENTIRE
PARTITION TO
UNDERSIDE OF
CEILING
(X'-X") SUBSCRIPT
INDICATES
FINISHED
PARTITION HEIGHT
IN
S
U B
S C
R
IP
T
H E
IG
H
T A
S
IN
D
IC
A T
E D
GENERAL NOTES:
1. FOR PARTITIONS WITH UNEQUAL LAYERS OF GYPSUM BOARD ON EACH SIDE, THE SIDE OF THE PARTITION
WITH THE TAG INDICATES WHERE THE EXTRA LAYER(S) OF GYPSUM BOARD ARE TO BE INSTALLED. REFER
TO PARTITION TYPES FOR MORE INFORMATION
2. DIMENSIONS TO METAL STUD PARTITIONS ARE MEASURED TO FINISH FACE UNLESS NOTED OTHERWISE
3. AT INFILL WITHIN OR EXTENSIONS ONTO EXISTING PARTITIONS, THE PARTITION TAG NOTED IS FOR INTENT
ONLY. FINISHED PARTITION FACES ARE TO ALIGN WITH ADJACENT EXISTING PARTITION FACES
4. SUBSCRIPTS MAY BE USED WITH ANY PARTITION TYPE
3'-0"UCD
XP3
(1 ) LAYER 5/8" GYPSUM
BOARD EACH SIDE
3 5/8" METAL STUD
FRAMING
(1 ) LAYER 5/8" GYPSUM
BOARD EACH SIDE
6" METAL STUD FRAMING
3" SOUND ATTENUATING
INSULATION
3" SOUND ATTENUATING
INSULATION
(1 ) LAYER 5/8" GYPSUM
BOARD
3 5/8" METAL STUD
FRAMING
3" SOUND ATTENUATING
INSULATION
STC 49 STC 49
4 7/8" 7 1/4"4 1/4"
B3 B6 B3b
(1 ) LAYER 5/8" GYPSUM
BOARD EACH SIDE
3 5/8" METAL STUD
FRAMING
3" SOUND ATTENUATING
INSULATION
UP TO 1HR FIRE RATING
UL DESIGN U419
STC 49
4 7/8"
(1 ) LAYER 5/8" GYPSUM
BOARD EACH SIDE
3 5/8" METAL STUD
FRAMING
STC 46
4 7/8"
A3 B6b
(1 ) LAYER 5/8" GYPSUM
BOARD EACH SIDE
6" METAL STUD FRAMING
3" SOUND ATTENUATING
INSULATION
UP TO 1HR FIRE RATING
UL DESIGN U419
STC 49
7 1/4"
B3p
(1 ) LAYER 5/8" GYPSUM
BOARD EACH SIDE
3 5/8" METAL STUD
FRAMING
3" SOUND ATTENUATING
INSULATION
STC 54
5 5/8"
3/4" ACOUSTICAL PANEL
(1 ) LAYER 5/8" GYPSUM
BOARD EACH SIDE
6", 16"GA STEEL STUD
FRAMING @16" OC.
6" SOUND ATTENUATING
INSULATION
STC 49
7 1/4"
B6s B6bs
(1 ) LAYER 5/8" GYPSUM
BOARD EACH SIDE
6", 16"GA STEEL STUD
FRAMING @16" OC.
6" SOUND ATTENUATING
INSULATION
UP TO 1HR FIRE RATING
UL DESIGN U419
STC 49
7 1/4"