This document is a detailed bid specification for the Marion National Cemetery New Land Expansion project (Project No. 817CM3025), located in Marion, Indiana. The comprehensive bid documents cover a complete cemetery expansion project, including new construction of administrative, maintenance, and committal service buildings, as well as site improvements such as columbaria, burial crypts, roadways, utilities, landscaping, and related infrastructure. The project involves multiple construction divisions, including site work, concrete, masonry, metals, wood, thermal and moisture protection, doors and windows, finishes, specialties, equipment, and building systems like plumbing, HVAC, electrical, communications, and electronic safety and security systems.

The bid documents are dated 10/30/2024 and include extensive technical specifications, drawing lists, and detailed requirements for each aspect of construction. The project scope encompasses approximately 10 acres of land expansion, with specific focus on creating new burial sections, installing precast concrete burial crypts, constructing new buildings, and developing comprehensive site infrastructure. Key elements include site surveys, demolition, earthwork, utility installations, landscaping, and the implementation of sophisticated building systems with direct digital control (DDC) for HVAC, comprehensive commissioning requirements, and sustainable design considerations. The project will be executed under the Department of Veterans Affairs National Cemetery Administration's oversight, with precise technical specifications governing every aspect of design and construction.

View the file

Other files

Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

MARION NATIONAL CEMETERY BID DOCUMENTS

NEW LAND EXPANSION 10/30/2024

NCA PROJECT NO. 817CM3025

TABLE OF CONTENTS

00 01 10-1

DEPARTMENT OF VETERANS AFFAIRS

NCA MASTER SPECIFICATIONS

TABLE OF CONTENTS

Section 00 01 10

DIVISION 00 - SPECIAL SECTIONS

00 01 15 List of Drawing Sheets

DIVISION 01 - GENERAL REQUIREMENTS

01 00 02 General Requirements (Minor NCA Projects) 01 32 17 Network Analysis Schedules (Microsoft Project Gantt Chart) 01 33 23 Shop Drawings, Product Data, and Samples 01 42 19 Reference Standards 01 43 39 Mockup Requirements 01 45 29 Testing Laboratory Services 01 57 19 Temporary Environmental Controls 01 74 19 Construction Waste Management 01 81 13 Sustainable Construction Requirements 01 91 00 General Commissioning Requirements

DIVISION 02 – EXISTING CONDITIONS

02 21 00 Site Surveys 02 41 10 Demolition and Site Clearing 02 82 13.41 Asbestos Abatement For Total Demolition Projects 02 83 33.13 Lead-Based Paint Removal and Disposal

DIVISION 03 – CONCRETE

03 30 53 (Short-Form) Cast-in-Place Concrete 03 48 21 Precast Concrete Burial Crypts (Double Depth Lawn Crypt) 03 48 24 Precast Concrete Columbarium Units 03 48 26 Precast Concrete Memorial Wall Units

DIVISION 04 – MASONRY

04 05 13 Masonry Mortaring 04 05 16 Masonry Grouting 04 05 31 Masonry Tuck Pointing 04 20 00 Unit Masonry 04 43 00 Natural Stone Veneer 04 73 00 Columbarium Niche Covers 04 73 10 Memorial Wall Markers

DIVISION 05 – METALS

05 40 00 Cold-Formed Metal Framing 05 50 00 Metal Fabrications

NCA PROJECT NO. 817CM3025

TABLE OF CONTENTS

00 01 10-2

DIVISION 06 – WOOD, PLASTICS AND COMPOSITES

06 10 00 Rough Carpentry 06 18 13 Structural Glued Laminated Timber 06 20 00 Finish Carpentry 06 43 00 Wood Stairs and Railings

DIVISION 07 - THERMAL AND MOISTURE PROTECTION

07 01 50.19 Preparation for Re-Roofing 07 08 00 Facility Exterior Closure Commissioning 07 13 52 Modified Bituminous Sheet Waterproofing 07 21 13 Thermal Insulation 07 21 23 Loose-Fill Insulation 07 22 00 Roof and Deck Insulation 07 31 29.13 Wood Shingles Repair 07 41 13 Standing Seam Metal Roofing 07 60 00 Flashing and Sheet Metal 07 84 00 Firestopping 07 92 00 Joint Sealants

DIVISION 08 - OPENINGS

08 01 52 Wood Window Repairs 08 11 13 Hollow Metal Doors and Frames 08 14 00 Interior Wood Doors 08 31 13 Access Doors and Frames 08 41 13 Aluminum-Framed Entrances and Storefronts 08 51 13 Aluminum Windows 08 52 00 Wood Windows 08 56 19 Pass Windows 08 71 00 Door Hardware 08 80 00 Glazing 08 90 00 Louvers and Vents

DIVISION 09 – FINISHES

09 05 16 Subsurface Preparation for Floor Finishes 09 22 16 Non-Structural Metal Framing 09 29 00 Gypsum Board 09 30 00 Specialty Moldings and Trims 09 30 13 Tiling 09 51 00 Acoustical Ceilings 09 65 13 Resilient Base and Accessories 09 65 19 Resilient Tile Flooring 09 65 36.13 Static-Dissipative Resilient Flooring 09 67 23 Resinous Flooring 09 68 00 Carpeting 09 72 16 Vinyl-Coated Fabric Wallcoverings 09 77 00 Fiberglass Reinforced Wall Panels 09 91 00 Painting

NCA PROJECT NO. 817CM3025

TABLE OF CONTENTS

00 01 10-3

DIVISION 10 – SPECIALTIES

10 14 00 Exterior Signage 10 14 05 Interior Signage 10 21 13 Toilet Compartments 10 28 00 Toilet and Bath Accessories 10 44 13 Fire Extinguisher Cabinets 10 51 13 Metal Lockers 10 56 13 Steel Shelving 10 75 00 Flagpoles

DIVISION 11 - EQUIPMENT

11 30 13 Small Commercial Appliances 11 83 00 Global Investigation Satellite System (GNSS) Reference System 11 83 02 GNSS & GIS Mapping and Geodata

DIVISION 12 – FURNISHINGS

12 24 00 Window Shades 12 32 00 Manufactured Wood Casework 12 36 00 Countertops

DIVISION 22 – PLUMBING

22 05 11 Common Work Results for Plumbing 22 05 12 General Motor Requirements for Plumbing Equipment 22 05 19 Meters and Gauges for Plumbing 22 05 23 General-Duty Valves for Plumbing Piping 22 07 11 Plumbing Insulation 22 08 00 Commissioning of Plumbing Systems 22 11 00 Facility Water Distribution 22 11 23 Domestic Water Pumps 22 13 00 Facility Sanitary and Vent Piping 22 33 00 Electric Water Heaters 22 40 00 Plumbing Fixtures

DIVISION 23 – HEATING, VENTILATING, AND AIR CONDITIONING

(HVAC)

23 05 11 Common Work Results for HVAC 23 05 12 General Motor Requirements for HVAC Equipment 23 05 41 Noise and Vibration Control for HVAC Piping and Equipment 23 05 93 Testing, Adjusting, and Balancing for HVAC 23 07 11 HVAC Insulation 23 08 00 Commissioning of HVAC Systems 23 09 23 DDC Controls For HVAC 23 23 00 Refrigerant Piping 23 31 00 HVAC Ducts and Casings 23 34 00 HVAC Fans 23 36 00 Air Terminal Units

NCA PROJECT NO. 817CM3025

TABLE OF CONTENTS

00 01 10-4

23 37 00 Air Outlets and Inlets 23 40 00 HVAC Air Cleaning Devices 23 81 00 Unitary HVAC Equipment 23 81 43 Air-Source Unitary Heat Pumps 23 82 16 Air Coils 23 82 39 Unit Heaters

DIVISION 25 – INTEGRATED AUTOMATION

25 10 10 Advanced Utility Metering System

DIVISION 26 – ELECTRICAL

26 05 11 Requirements for Electrical Installations 26 05 19 Low-Voltage Electrical Power Conductors and Cables 26 05 26 Grounding and Bonding for Electrical Systems 26 05 33 Raceway and Boxes for Electrical Systems 26 05 41 Underground Electrical Construction 26 05 73 Overcurrent Protective Device Coordination Study 26 08 00 Commissioning of Electrical Systems 26 09 23 Lighting Controls 26 24 13 Distribution Switchboards 26 24 16 Panelboards 26 27 26 Wiring Devices 26 29 11 Motor Controllers 26 29 21 Enclosed Switches and Circuit Breakers 26 32 13 Engine Generators 26 36 23 Automatic Transfer Switches 26 41 00 Facility Lightning Protection 26 51 00 Interior Lighting 26 56 00 Exterior Lighting

DIVISION 27 – COMMUNICATIONS

27 05 00 Common Work Results for Communications 27 05 26 Grounding and Bonding for Communications Systems 27 05 33 Conduits and Backboxes for Communications Systems 27 08 00 Commissioning of Communication Systems 27 10 00 Structured Cabling 27 11 00 Communications Equipment Room Fittings

DIVISION 28 – ELECTRONIC SAFETY AND SECURITY

28 08 00 Commissioning of Electronic Safety and Security Systems 28 10 00 Access Control 28 20 00 Video Surveillance 28 31 00 Intrusion Detection

DIVISION 31 – EARTHWORK

31 20 11 Earth Moving (Short Form) 31 23 19 Dewatering

NCA PROJECT NO. 817CM3025

TABLE OF CONTENTS

00 01 10-5

DIVISION 32 – EXTERIOR IMPROVEMENTS

32 05 23 Cement and Concrete for Exterior Improvements 32 08 00 Commissioning of Planting Irrigation Systems 32 12 16 Asphalt Paving 32 17 23 Pavement Markings 32 31 19 Decorative Metal Fences and Gates 32 33 00 Site Furnishings 32 84 00 Planting Irrigation 32 90 00 Planting

DIVISION 33 – UTILITIES

33 10 00 Water Utilities 33 30 00 Sanitary Sewerage Utilities 33 40 00 Storm Sewer Utilities 33 41 13 Foundation Drainage

APPENDIX

A Geotechnical Report B Asbestos Inspection Report C Limited Lead Paint Testing Results

NCA PROJECT NO. 817CM3025

00 01 15 - 1

LIST OF DRAWING SHEETS

SECTION 00 01 15

LIST OF DRAWING SHEETS

The drawings listed below accompanying this specification form a part of the contract.

Drawing No. Title

GENERAL

GI001 COVER SHEET

GI002 SHEET INDEX

EXISTING CONDITIONS

VF101 EXISTING CONDITIONS SURVEY

VF102 EXISTING CONDITIONS SURVEY

BORING LOCATIONS

BL100 GEOTECHNICAL BORING LOCATIONS

BL601 GEOTECHNICAL BORING LOGS

BL602 GEOTECHNICAL BORING LOGS

DEMOLITION & OPERATIONS

CD101 DEMOLITION PLAN

CD102 INDIANA AVENUE DEMOLITION PLAN

CD103 NORTH DEMOLITION PLAN

OJ101 OPERATIONS ACCESS & LOGISTICS PLAN

OJ501 OPERATIONS DETAILS

OJ502 SWPPP

SITE PLANS

CS101 SITE PLAN

CS102 MAIN ENTRY SITE PLAN

CS103 PIC ADMIN BLDG & C.S.S. SITE PLAN

CS104 MAINTENANCE SITE PLAN

CS501 CROSS SECTION SITE DETAILS

CS502 TYPICAL SITE DETAILS

CS503 TYPICAL SITE DETAILS

CS504 TYPICAL SITE DETAILS

CP101 PAVING PLAN

NCA PROJECT NO. 817CM3025

00 01 15 - 2

LIST OF DRAWING SHEETS

GRAVESITE BURIAL SECTIONS

CJ401 SECTION 15 NUMBERING PLAN

CJ402 SECTION 15 LAYOUT PLAN

CJ403 SECTION 15 COORDINATION PLAN

CJ404 SECTION 16 NUMBERING PLAN

CJ405 SECTION 16 LAYOUT PLAN

CJ406 SECTION 16 COORDINATION PLAN

CJ407 SECTION 17 NUMBERING PLAN

CJ408 SECTION 17 LAYOUT PLAN

CJ409 SECTION 17 COORDINATION PLAN

CJ410 SECTION CS-7 NUMBERING PLAN

CJ411 SECTION CS-7 LAYOUT PLAN

CJ412 SECTION CS-7 COORDINATION PLAN

CJ413 SECTION CS-8 NUMBERING PLAN

CJ414 SECTION CS-8 LAYOUT PLAN

CJ415 SECTION CS-8 COORDINATION PLAN

CJ501 CRYPT DETAILS

CJ502 CRYPT DETAILS

STREET PLAN & PROFILE

CR101 CEMETERY ROAD 100+00 TO 107+00

CR102 CEMETERY ROAD 107+00 TO 112+00

CR103 INDIANA AVENUE 207+00 TO 214+00

CR104 KUDER PLANCE 300+00 TO 306+00

CR105 CORTAGE LANE 400+00 TO 405+00

CR106 CORTAGE LANE 404+00 TO 409+75

GRADING

CG101 GRADING PLAN

CG102 GRADING PLAN NORTH

CG103 GRADING PLAN MIDDLE

CG104 GRADING PLAN SOUTH

CG105 MAINTENANCE GRADING PLAN

UTILITIES

CU101 UTILITY PLAN

NCA PROJECT NO. 817CM3025

00 01 15 - 3

LIST OF DRAWING SHEETS

CU102 UTILITY PLAN NORTH

CU103 UTILITY PLAN MIDDLE

CU104 UTILITY PLAN SOUTH

CU105 MAINENANCE UTIITY PLAN

CU106 COLUMBARIUM UTILITY PLAN

CU200 UTILITY PROFILES

FOUNDATION PLANS

LS101 COLUMBARIUM FOUNDATION PLAN

LS102 MEMORIAL WALL FOUNDATION PLAN

LS103 OVERALL ENTRANCE WALL FOUNDATION PLAN

LS103.1 ENTRANCE WALL FOUNDATION PLAN

LS103.2 ENTRANCE WALL FOUNDATION PLAN

LS104 WIND WALL FOUDNATION PLAN

PRECAST LAYOUT PLANS

LS111 COLUMBARIUM PRECAST LAYOUT PLAN

LS112 MEMORIAL WALL PRECAST LAYOUT PLAN

LAYOUT & JOINTING PLANS

LS121 COLUMBARIUM LAYOUT AND JOINTING PLAN

LS122 MEMORIAL WALL LAYOUT AND JOINTING PLAN

LS123 OVERALL ENTRANCE WALL LAYOUT AND JOINTING PLAN

LS123.1 ENTRANCE WALL LAYOUT AND JOINTING PLAN

LS123.2 ENTRANCE WALL LAYOUT AND JOINTING PLAN

LS124 WIND WALL LAYOUT AND JOINTING PLAN

ADDRESSING PLANS

LS141 COLUMBARIUM ADDRESSING PLAN

LS142 MEMORIAL WALL ADDRESSING PLAN

CAP LAYOUT PLANS

LS131 COLUMBARIUM CAP LAYOUT PLAN

LS132 MEMORIAL WALL CAP LAYOUT PLAN

LS133 OVERALL ENTRANCE WALL CAP LAYOUT PLAN

LS133.1 ENTRANCE WALL CAP LAYOUT PLAN

LS133.2 ENTRANCE WALL CAP LAYOUT PLAN

NCA PROJECT NO. 817CM3025

00 01 15 - 4

LIST OF DRAWING SHEETS

LS134 WIND WALL CAP LAYOUT PLAN

ELEVATIONS

LS201 COLUMBARIUM ELEVATIONS

LS202 MEMORIAL WALL ELEVATIONS

LS203 ENTRANCE WALL ELEVATIONS

LS204 WIND WALL ELEVATIONS

SECTIONS

LS301 COLUMBARIUM SECTIONS

LS302 MEMORIAL WALL SECTIONS

LS303 ENTRANCE WALL SECTIONS

LS304 WIND WALL SECTIONS

DETAILS

LS501 PRECAST COLUMBARIUM UNIT DETAILS

LS502 PRECAST MEMORIAL WALL UNIT DETAILS

LS503 CAP PROFILE & PANEL DETAILS

LS504 CAP DETAILS

LS505 TYPICAL DETAILS

SITE ELEMENT GRADING

LG101 COLUMBARIUM GRADING PLAN

LG102 MEMORIAL WALL GRADING PLAN

LG103.1 ENTRANCE WALL GRADING PLAN

LG103.2 ENTRANCE WALL GRADING PLAN

LG104 WIND WALL GRADING PLAN

WAYFINDING & SITE FURNISHINGS

LK101 SECTION MARKER SIGNAGE PLAN

LK102 SITE SIGNAGE PLAN

LK103 SITE FURNISHINGS PLAN

LK501 SITE SIGNAGE DETAILS

LK502 SITE SIGNAGE DETAILS

LK503 SITE FURNISHINGS DETAILS

NCA PROJECT NO. 817CM3025

00 01 15 - 5

LIST OF DRAWING SHEETS

PLANTING

LP101 PLANTING PLAN

LP111 PLANTING ENLARGMENTS

LP112 PLANTING ENLARGEMENTS

LP113 PLANTING ENLARGEMENTS

LP114 BUILDING PLANTING ENLARGEMENTS

LP501 PLANTING DETAILS

ARCHITECTURE

1001-GI111 PIC ADMIN. BLDG – 1ST FLOOR LIFE SAFETY PLAN

1001-AE111 PIC ADMIN. BLDG – 1ST FLOOR PLAN AND RCP

1001-AE112 PIC ADMIN. BLDG - ROOF PLAN AND ROOF DETAILS

1001-AE201 PIC ADMIN. BLDG - EXTERIOR ELEVATIONS

1001-AE211 PIC ADMIN. BLDG - ENLARGED PLANS AND INTERIOR

ELEVATIONS

1001-AE301 PIC ADMIN. BLDG – BUILDING SECTIONS

1001-AE311 PIC ADMIN. BLDG – WALL SECTIONS

1001-AE312 PIC ADMIN. BLDG – WALL SECTIONS

1001-AE501 PIC ADMIN. BLDG – EXTERIOR PLAN DETAILS

1001-AE520 PIC ADMIN. BLDG – EXTERIOR SECTION DETAILS

1001-AE550 PIC ADMIN. BLDG – INTERIOR SECTION DETAILS

1001-AE601 PIC ADMIN. BLDG – PARTITION TYPES AND DETAILS

1001-AE602 PIC ADMIN. BLDG – DOOR SCHEDULE AND DETAILS

1001-AF101 PIC ADMIN. BLDG – 1ST FLOOR FINISH AND FURNITURE

PLAN

1001-AF600 PIC ADMIN. BLDG – MATERIAL AND ROOM FINISH

SCHEDULES

1001-AW111 PIC ADMIN. BLDG – 1ST FLOOR WAYFINDING PLAN

1001-AW601 PIC ADMIN. BLDG – WAYFINDING SCHEDULES AND

DETIALS

1001-QH110 PIC ADMIN. BLDG – 1ST FLOOR EQUIPMENT PLAN

3005-GI111 MAINTENANCE BLDG - 1ST AND MEZZANINE LIFE SAFETY

PLANS

3005-GI112 MAINTENANCE BLDG - 1ST AND MEZZANINE PHASING

PLANS

3005-AD111 MAINTENANCE BLDG - 1ST AND MEZZANINE DEMOLIATION

PLANS

NCA PROJECT NO. 817CM3025

00 01 15 - 6

LIST OF DRAWING SHEETS

3005-AD112 MAINTENANCE BLDG - DEMOLITION SECTION DETAILS

3005-AD201 MAINTENANCE BLDG – DEMOLITION EXTERIOR

ELEVATIONS

3005-AE111 MAINTENANCE BLDG - 1ST AND MEZZANINE FLOOR PLANS

3005-AE112 MAINTENANCE BLDG – 1ST AND MEZZANINE DIMENSION

PLANS

3005-AC111 MAINTENANCE BLDG - 1ST FLOOR AND MEZZANINE

REFLECTED CEILING PLANS

3005-AE191 MAINTENANCE BLDG – ROOF PLAN AND ROOF DETAILS

3005-AE201 MAINTENANCE BLDG - EXTERIOR ELEVATIONS

3005-AE211 MAINTENANCE BLDG - ENLARGED PLANS AND INTERIOR

ELEVATIONS

3005-AE301 MAINTENANCE BLDG - BUILDING SECTIONS

3005-AE302 MAINTENANCE BLDG - BUILDING SECTIONS

3005-AE311 MAINTENANCE BLDG – WALL SECTIONS

3005-AE312 MAINTENANCE BLDG – WALL SECTIONS

3005-AE320 MAINTENANCE BLDG - STAIR ENLARGED FLOOR PLANS,

SECTIONS & DETAIL

3005-AE540 MAINTENANCE BLDG - INTERIOR PLAN DETAILS

3005-AE550 MAINTENANCE BLDG - INTERIOR SECTION DETAILS

3005-AE551 MAINTENANCE BLDG – INTERIOR SECTION DETAILS

3005-AE560 MAINTENANCE BLDG - CEILING DETAILS

3005-AE601 MAINTENANCE BLDG - PARTITION TYPES AND DETAILS

3005-AE602 MAINTENANCE BLDG - DOOR SCHEDULE AND DETAILS

3005-AE640 MAINTENANCE BLDG - MOUNTING HEIGHTS

3005-AF101 MAINTENANCE BLDG - 1ST FLOOR FINISH AND

FURNITURE PLANS

3005-AF600 MAINTENANCE BLDG - MATERIAL AND ROOM FINISH

SCHEDULES

3005-AW111 MAINTENANCE BLDG - 1ST AND MEZZANINE WAYFINDING

PLANS

3005-AW601 MAINTENANCE BLDG - WAYFINDING SCHEDULES AND

DETAILS

3005-QH110 MAINTENANCE BLDG - 1ST FLOOR EQUIPMENT PLAN

4802-AE111 COMMITTAL SHELTER - FLOOR PLAN AND RCP

4802-AE112 COMMITTAL SHELTER - ROOF PLANS AND DETAILS

4802-AE201 COMMITTAL SHELTER - EXTERIOR ELEVATIONS

NCA PROJECT NO. 817CM3025

00 01 15 - 7

LIST OF DRAWING SHEETS

4802-AE301 COMMITTAL SHELTER - BUILDING & WALL SECTIONS

AND DETAILS

4802-AE602 COMMITTAL SHELTER - DOOR SCHEDULE AND DETAILS

STRUCTURAL

1001-S001 PIC ADMIN. BLDG - NOTE SHEET

1001-S101 PIC ADMIN. BLDG - FOOTING & FOUNDATION PLAN

1001-S201 PIC ADMIN. BLDG - ROOF FRAMING PLAN

1001-S301 PIC ADMIN. BLDG – FOOTING & FOUNDATION DETAILS

1001-S401 PIC ADMIN. BLDG – FRAMING DETAILS

3005-S001 MAINTENANCE BLDG - NOTE SHEET

3005-S101 MAINTENANCE BLDG – FOOTING & FOUNDATION PLAN

3005-S201 MAINTENANCE BLDG – MEZZANINE FLOOR FRAMING PLAN

3005-S202 MAINTENANCE BLDG – ROOF FRAMING PLAN

3005-S301 MAINTENANCE BLDG – FOOTING & FOUNDATION DETAILS

3005-S401 MAINTENANCE BLDG – FRAMING DETAILS

4802-S001 COMMITTAL SHELTER - NOTE SHEET

4802-S101 COMMITTAL SHELTER – FOUNDATION & FRAMING PLAN

4802-S201 COMMITTAL SHELTER – FOUNDATION & FRAMING

DETAILS

COL-S101 COLUMBARIUM – FOOTING & FOUNDATION PLAN

ENT-S101 ENTRANCE WALL – FOOTING & FOUNDATION PLAN

PLUMBING

1001-P000 PIC ADMIN. BLDG - PLUMBING COVERSHEET

1001-P100 PIC ADMIN. BLDG - UNDERFLOOR PLAN - PLUMBING

1001-P111 PIC ADMIN. BLDG – 1ST FLOOR PLAN - PLUMBING

1001-P131 PIC ADMIN. BLDG – ROOF PLAN - PLUMBING

1001-P301 PIC ADMIN. BLDG - PLUMBING DETAILS

1001-P401 PIC ADMIN. BLDG - PLUMBING DIAGRAMS

1001-P402 PIC ADMIN. BLDG - PLUMBING DIAGRAMS

1001-P501 PIC ADMIN. BLDG - PLUMBING SCHEDULES

3005-P000 MAINTENANCE BLDG - PLUMBING COVERSHEET

3005-PD111 MAINTENANCE BLDG – UNDERFLOOR & 1ST FLOOR PLANS

– PLUMBING DEMOLITION

3005-P100 MAINTENANCE BLDG – UNDERFLOOR & 1ST FLOOR PLANS

- PLUMBING

NCA PROJECT NO. 817CM3025

00 01 15 - 8

LIST OF DRAWING SHEETS

3005-P111 MAINTENANCE BLDG – 1ST FLOOR AND MEZZANINE PLANS

- PLUMBING

3005-P301 MAINTENANCE BLDG - PLUMBING DETAILS

3005-P401 MAINTENANCE BLDG – SANITARY WASTE & VENT RISER

DIAGRAM

3005-P402 MAINTENANCE BLDG – DOMESTIC WATER DISTRIBUTION

RISER DIAGRAM

3005-P501 MAINTENANCE BLDG - PLUMBING SCHEDULES

PIPING & VENTILATION

1001-MP000 PIC ADMIN. BLDG - PIPING COVERSHEET

1001-MP111 PIC ADMIN. BLDG – 1ST FLOOR PLAN – MECHANICAL

PIPING

1001-MV000 PIC ADMIN. BLDG - VENTILATION COVERSHEET

1001-MV111 PIC ADMIN. BLDG – 1ST FLOOR PLAN - VENTILATION

1001-MV211 PIC ADMIN. BLDG – ENLARGED VIEWS - VENTILATION

1001-MV301 PIC ADMIN. BLDG – VENTILATION DETAILS

1001-MV401 PIC ADMIN. BLDG - CONTROL DIAGRAMS

1001-MV501 PIC ADMIN. BLDG - VENTILATION SCHEDULES

1001-MV502 PIC ADMIN. BLDG - VENTILATION SCHEDULES

3005-MP000 MAINTENANCE BLDG - PIPING COVERSHEET

3005-MPD111 MAINTENANCE BLDG – 1ST FLOOR & MEZZANINE PLANS –

PIPING DEMOLITION

3005-MP111 MAINTENANCE BLDG – 1ST FLOOR & MEZZANINE PLANS –

MECH PIPING

3005-MV000 MAINTENANCE BLDG – VENTILATION COVERSHEET

3005-MVD111 MAINTENANCE BLDG – 1ST FLOOR & MEZZANINE PLAN –

VENILATION DEMOLITION

3005-MV102 MAINTENANCE BLDG – 1ST FLOOR & MEZZANINE PLANS –

VENTILATION

3005-MV103 MAINTENANCE BLDG – ENLARGED PLANS - VENTILATION

3005-MV301 MAINTENANCE BLDG – VENTILATION DETAILS

3005-MV401 MAINTENANCE BLDG - CONTROL DIAGRAMS

3005-MV501 MAINTENANCE BLDG - VENTILATION SCHEDULES

3005-MV502 MAINTENANCE BLDG - VENTILATION SCHEDULES

NCA PROJECT NO. 817CM3025

00 01 15 - 9

LIST OF DRAWING SHEETS

ELECTRICAL

1001-E000 PIC ADMIN. BLDG - ELECTRICAL COVERSHEET

1001-E001 PIC ADMIN. BLDG – OVERALL ELECTRICAL SITE PLAN

1001-E002 PIC ADMIN. BLDG – ELECTRICAL SITE PLAN

1001-E101 PIC ADMIN. BLDG – LIGHTING PLAN

1001-E201 PIC ADMIN. BLDG – POWER PLAN

1001-E211 PIC ADMIN. BLDG – EQUIPMENT POWER PLAN

1001-E301 PIC ADMIN. BLDG – ELECTRICAL ONE-LINE DIAGRAM

1001-E501 PIC ADMIN. BLDG – ELECTRICAL DETAILS

1001-E601 PIC ADMIN. BLDG – ELECTRICAL SCHEDULES

3005-E003 MAINTENANCE BLDG - ELECTRICAL SITE PLAN

3005-ED101 MAINTENANCE BLDG – 1ST FLOOR LIGHTING DEMOLITION

PLAN

3005-ED102 MAINTENANCE BLDG – MEZZANINE LIGHTING

DEMOLITION PLAN

3005-ED201 MAINTENANCE BLDG – 1ST FLOOR POWER DEMOLITION

PLAN

3005-ED202 MAINTENANCE BLDG – MEZZANINE POWER DEMOLITION

PLAN

3005-E101 MAINTENANCE BLDG – 1ST FLOOR LIGHTING PLAN

3005-E102 MAINTENANCE BLDG - MEZZANINE LIGHTING PLAN

3005-E201 MAINTENANCE BLDG – 1ST FLOOR POWER PLAN

3005-E202 MAINTENANCE BLDG – MEZZANINE POWER PLAN

3005-E211 MAINTENANCE BLDG – 1ST FLOOR EQUIPMENT POWER

PLAN

3005-E212 MAINTENANCE BLDG – MEZZANINE EQUIPEMENT POWER

PLAN

3005-E301 MAINTENANCE BLDG - ELECTRICAL ONE-LINE DIAGRAMS

3005-E501 MAINTENANCE BLDG - ELECTRICAL DETAILS

3005-E601 MAINTENANCE BLDG – ELECTRICAL SCHEDULES

4802-E004 COMMITTAL SHELTER - ELECTRICAL SITE PLAN

4802-E101 COMMITTAL SHELTER – ELECTRICAL PLAN

4802-E501 COMMITTAL SHELTER – ELECTRICAL DETAILS &

SCHEDULES

TECHNOLOGY

T000 TECHNOLOGY COVER SHEET

NCA PROJECT NO. 817CM3025

00 01 15 - 10

LIST OF DRAWING SHEETS

TS111 SITE PLAN - TECHNOLOGY

1001-TN111 PIC ADMIN. BLDG - TECHNOLOGY

3005-TD111 1ST FLOOR AND MEZZANINE DEMOLITION PLAN –

TECHNOLOGY

3005-TN111 1ST FLOOR & MEZZANINE PLAN - TECHNOLOGY

4802-TN111 COMMITTAL SHELTER FLOOR PLAN - TECHNOLOGY

T400 TECHNOLOGY DETAILS

T401 TECHNOLOGY DETAILS

T500 TECHNOLOGY DIAGRAMS

T600 TECHNOLOGY SCHEDULES

IRRIGATION

IR101 SITE IRRIGATION PLAN MAINLINE AND WIRING

IR201 SITE IRRIGATION PLAN SPRINKLER AND LATERAL

PIPING

IR501 IRRIGATION DETAILS

IR-502 IRRIGATION DETAILS

IR-503 IRRIGATION PUMP DETAIL

D-201 DEMOLITION PLAN – ADD BASE BID

CS-201 SITE & GRADING PLAN – ADD BASE BID

CU-201 UTILITY PLAN – BASE BID

IR-201 SITE IRRIGATION – ADD BASE BID

IR-502 PUMP DETAILS BASE BID

E000 ELECTRICAL COVERSHEET BASE BID

E001 SITE IRRIGATION PLAN - ELECTRICAL

E300 ELECTRICAL DETAILS BASE BID

IR-202 SITE IRRIGATION PLAN – ADD OPTION 1

IR-203 IRRIGATION COVERAGE PLAN – ADD OPTION 1

- - - END - - -

NCA PROJECT NO. 817CM3025

i

GENERAL REQUIREMNETS (MINOR NCA PROJECTS)

SECTION 01 00 02

GENERAL REQUIREMENTS (MINOR NCA PROJECTS)

TABLE OF CONTENTS

1.1 GENERAL INTENTION

1.2 STATEMENT OF BID ITEM(S)

1.3 SPECIFICATIONS AND DRAWINGS FOR CONTRACTOR

1.4 FIRE SAFETY

1.5 OPERATIONS AND STORAGE AREAS

1.6 ALTERATIONS

1.7 DISPOSAL AND RETENTION

1.8 PROTECTION OF EXISTING VEGETATION, STRUCTURES, EQUIPMENT,

UTILITIES, AND IMPROVEMENTS

1.9 RESTORATION

1.10 PHYSICAL DATA

1.11 PROFESSIONAL SURVEYING SERVICES

1.12 LAYOUT OF WORK

1.13 AS-BUILT DRAWINGS

1.14 USE OF ROADWAYS

1.15 RE FIELD OFFICE

1.16 TEMPORARY TOILETS

1.17 AVAILABILITY AND USE OF UTILITY SERVICES

1.18 INSTRUCTIONS

1.19 GOVERNMENT-FURNISHED PROPERTY

1.20 CONSTRUCTION SIGN

1.21 SAFETY SIGN

1.22 CONSTRUCTION DIGITAL IMAGES

1.23 FINAL ELEVATION PHOTOGRAPHS

1.24 HISTORIC PRESERVATION

1.25 PROJECT HEALTH AND SAFETY PLAN

NCA PROJECT NO. 817CM3025

ii

GENERAL REQUIREMNETS (MINOR NCA PROJECTS)

This page intentionally blank

MARION NATIONAL CEMETERY 65% CONSTRUCTION DOCUMENTS

NEW LAND EXPANSION 8/3/2023

NCA PROJECT NO. 817CM3025

GENERAL REQUIREMENTS

01 00 02 - 1

SECTION 01 00 02

GENERAL REQUIREMENTS (MINOR NCA PROJECTS)

1.1 GENERAL INTENTION

A. Contractor shall completely prepare site for building operations, including demolition and removal of existing structures, and furnish labor, materials, equipment and services and perform and complete all work for Marion National Cemetery New Land Expansion(Insert the Project as required by drawings and specifications.

B. Visits to the site by Bidders may be made only by appointment with the

Cemetery Director.

C. Offices of Anderson Engineering of Minnesota, LLC , as

Architect-Engineers (A/E), may render certain technical services during construction. Such services shall be considered as advisory to the

Government and shall not be construed as expressing or implying a contractual act of the Government without affirmations by Contracting

Officers Representative (COR) or his duly authorized representative.

D. All Testing Laboratory services will be retained and paid for by the

Contractor (see Spec Section 01 45 29, Testing Laboratory Services).

However, the Department of Veterans Affairs may elect to retain its own

Testing Laboratory for any purpose. Before placement and installation of work subject to tests by testing laboratory retained by Department of Veterans Affairs, the Contractor shall notify the COR in sufficient time to enable testing laboratory personnel to be present at the site in time for proper taking and testing of specimens and field inspection. Such prior notice shall be not less than three work days unless otherwise designated by the COR.

E. All employees of general contractor and subcontractors shall comply with security requirements as established by the COR, be identified by name and employer. They shall be restricted from unauthorized access.

F. Prior to commencing work, general contractor shall provide proof that a

OSHA certified “competent person” (CP) (29 CFR 1926.20(b)(2) will maintain a presence at the work site whenever the general or subcontractors are present.

G. Training:

1. All employees of general contractor or subcontractors shall, at the minimum, have successfully completed the 10-hour OSHA certified

Construction Safety course and/or other relevant competency training, as determined by VA CP.

NCA PROJECT NO. 817CM3025

GENERAL REQUIREMENTS

01 00 02 - 2

2. Submit OSHA training records of all employees for approval before the start of work.

1.2 STATEMENT OF BID ITEM(S)

A. ITEM I, GENERAL CONSTRUCTION: Installation of all work shown on the plans and described in the specifications including but not limited to:

general construction, alterations, roads, walks, grading, drainage, irrigation, landscaping, fencing, pre-placed crypts, in-ground cremains, columbarium, flag assembly area, entrance feature, administration building, committal service shelter, maintenance building renovation and construction of other items as required to complete all the work described in the contract documents. .

1.3 UTILITY AND PERMIT FEES

A. The following fees shall be paid by the contractor on behalf of the government.

1. Telephone/Data – The contractor shall include an allowance of

$15,000 for payment to the Telephone/Data Company to install cabling for telephone/data lines to the administration building and all required associated equipment to establish a live internet/communication connection. The Contractor shall coordinate initiation of this service request with the VA and shall accommodate such work within the project schedule.

2. Indiana Michigan Power (Electricity) – The contractor shall prepare all applications, associated planning requirements and planning fees and include an allowance of $100,000 for payment to Indiana Michigan

Power to relocate the existing power pole at the main entrance and install cabling for electricity from the Indiana Michigan Power source to the meter/transformer. All cabling from meter/transformer to site elements within the property as shown on the plans and specifications shall be included in the contract price.

3. City of Marion

a. Building and Grading Permit – Contractor shall prepare all permits and obtain and pay for the building, grading, etc. permits that are required by the City of Marion.

b. Domestic Water and Sanitary Sewer – The contractor shall obtain and pay for all associated materials and requirements for connections to the City of Marion domestic water and sanitary sewer.

4. State of Indiana Department of Environmental Management.

NCA PROJECT NO. 817CM3025

GENERAL REQUIREMENTS

01 00 02 - 3

a. NPDES - The Contractor shall apply for and obtain from IDEP

“Semi-public and minor municipal application forms”.

1.4 CONSTRUCTION SECURITY REQUIREMENTS

A. Security Plan:

1. The security plan defines both physical and administrative security procedures that will remain effective for the entire duration of the project.

2. The General Contractor is responsible for assuring that all sub-contractors working on the project and their employees also comply with these regulations.

B. Security Procedures:

1. General Contractor’s employees shall not enter the site without following the procedures approved by the COR. They may also be subject to inspection of their personal effects when entering or leaving the project site.

2. For working outside the “regular hours” as defined in the contract, The General Contractor shall give 3 days notice to the COR so that appropriate arrangements can be provided for the Cemetery employees.

This notice is separate from any notices required for utility shutdown described later in this section.

3. No photography of VA premises is allowed without written permission of the COR.

4. VA reserves the right to close down or shut down the project site and order General Contractor’s employees off the premises in the event of a national emergency. The General Contractor may return to the site only with the written approval of the COR.

C. Guards:

1. The General Contractor shall provide unarmed guards at the project site when theft or vandalism warrants.

D. Key Control:

1. The General Contractor shall provide duplicate keys and lock combinations to the RE/COR for the purpose of security inspections of every area of project including tool boxes and parked machines, and to take any necessary emergency action.

E. Document Control:

1. Before starting any work, the General Contractor/Sub Contractors shall submit an electronic security memorandum describing the

NCA PROJECT NO. 817CM3025

GENERAL REQUIREMENTS

01 00 02 - 4 approach to following goals and maintaining confidentiality of

“sensitive information”.

2. The General Contractor is responsible for safekeeping of all drawings, project manual and other project information. This information shall be shared only with those with a specific need to accomplish the project.

3. Certain documents, sketches, videos or photographs and drawings may be marked “Law Enforcement Sensitive” or “Sensitive Unclassified”.

Secure such information in separate containers and limit the access to only those who will need it for the project. Return the information to the COR upon request.

4. These security documents shall not be removed or transmitted from the project site without the written approval of COR.

5. All paper waste or electronic media such as CD’s and diskettes shall be shredded and destroyed in a manner acceptable to the VA.

6. Notify COR immediately when there is a loss or compromise of

“sensitive information”.

7. All electronic information shall be stored in a specified location following VA standards and procedures using an Engineering Document

Management Software (EDMS).

a. Security, access and maintenance of all project drawings, both scanned and electronic shall be performed and tracked through the

EDMS system.

b. “Sensitive information” including drawings and other documents may be attached to e-mail provided all VA encryption procedures are followed.

F. Motor Vehicle Restrictions

1. Vehicle authorization request shall be required for any vehicle entering the site and such request shall be submitted 24 hours before the date and time of access. Access shall be restricted to picking up and dropping off materials and supplies.

1.5 FIRE SAFETY

A. Applicable Publications: Publications listed below form part of this

Article to the extent referenced. Publications are referenced in text by basic designations only.

NCA PROJECT NO. 817CM3025

GENERAL REQUIREMENTS

01 00 02 - 5

1. American Society for Testing and Materials (ASTM):

E84-2009a Surface Burning Characteristics of Building

Materials

2. National Fire Protection Association (NFPA):

10-2010 Standard for Portable Fire Extinguishers

30-2008 Flammable and Combustible Liquids Code

51B-2009 Standard for Fire Prevention During Welding, Cutting and Other Hot Work

70-2008 National Electrical Code

241-2009 Standard for Safeguarding Construction, Alteration, and Demolition Operations

3. Occupational Safety and Health Administration (OSHA):

29 CFR 1926 Safety and Health Regulations for Construction

B. Fire Safety Plan: Establish and maintain a fire protection program in accordance with 29 CFR 1926. Prior to start of work, prepare a plan detailing project-specific fire safety measures, including periodic status reports, and submit to COR and Cemetery Director for review for compliance with contract requirements in accordance with Section 01 33

23, SHOP DRAWINGS, PRODUCT DATA AND SAMPLES. Prior to any worker for the contractor or subcontractor’s beginning work, they shall undergo a safety briefing provided by the General Contractor’s competent person per OSHA requirements. This briefing shall include information on the construction limits, safety guidelines, means of egress, break areas, work hours, locations of restrooms, use of NCA equipment, etc.

Documentation shall be provided to the RE/COR that individuals have undergone the Contractor’s safety briefing.

C. Site and Building Access: Maintain free and unobstructed access to emergency services and for fire, police and other emergency response forces in accordance with NFPA 241.

D. Separate temporary facilities, such as trailers, storage sheds, and dumpsters, from existing buildings and new construction by distances in accordance with NFPA 241. For small facilities with less than 6 m (20 feet) exposing overall length, separate by 3m (10 feet).

E. Temporary Construction Partitions:

1. Install and maintain temporary construction partitions to provide smoke-tight separations between construction areas, the areas that are described in phasing requirements and adjoining areas. Construct

NCA PROJECT NO. 817CM3025

GENERAL REQUIREMENTS

01 00 02 - 6 partitions of gypsum board or treated plywood (flame spread rating of 25 or less in accordance with ASTM E84) on both sides of fire retardant treated wood or metal steel studs. Extend the partitions through suspended ceilings to floor slab deck or roof. Seal joints and penetrations. At door openings, install Class C, ¾ hour fire/smoke rated doors with self-closing devices.

2. Install fire-rated temporary construction partitions to maintain integrity of existing exit passageways, fire-rated enclosures of hazardous areas, horizontal exits, smoke barriers, and opening enclosures.

3. Close openings in smoke barriers and fire-rated construction to maintain fire ratings. Seal penetrations with listed through-penetration firestop materials in accordance with Section 07 84 00, FIRESTOPPING.

F. Temporary Heating and Electrical: Install, use and maintain installations in accordance with 29 CFR 1926, NFPA 241 and NFPA 70.

G. Means of Egress: Do not block exiting for occupied buildings, including paths from exits to roads. Minimize disruptions and coordinate with COR and Cemetery Director.

H. Egress Routes for Construction Workers: Maintain free and unobstructed egress. Inspect daily. Report findings and corrective actions weekly to

COR.

I. Fire Extinguishers: Provide and maintain extinguishers in construction areas and temporary storage areas in accordance with 29 CFR 1926, NFPA

241 and NFPA 10.

J. Flammable and Combustible Liquids: Store, dispense and use liquids in accordance with 29 CFR 1926, NFPA 241 and NFPA 30.

K. Existing Fire Protection: Do not impair automatic sprinklers, smoke and heat detection, and fire alarm systems, except for portions immediately under construction, and temporarily for connections. Request interruptions in accordance with Article, OPERATIONS AND STORAGE AREAS, and coordinate with COR. All existing or temporary fire protection systems (fire alarms) located in construction areas shall be tested as coordinated with the Cemetery. Parameters for the testing and results of any tests performed shall be recorded by the Cemetery and copies provided to the COR.

NCA PROJECT NO. 817CM3025

GENERAL REQUIREMENTS

01 00 02 - 7

L. Smoke Detectors: Prevent accidental operation. Remove temporary covers at end of work operations each day. Coordinate with RE/COTR.

M. Hot Work: Perform and safeguard hot work operations in accordance with

NFPA 241 and NFPA 51B. Coordinate with COR. Designate Contractor's responsible project-site fire prevention program manager to permit hot work. Coordinate with RE/COR.

N. Fire Hazard Prevention and Safety Inspections: Inspect entire construction areas weekly. Coordinate with, and report findings and corrective actions weekly to RE/COR.

O. Smoking: Smoking is prohibited in and adjacent to construction areas inside existing buildings and additions under construction. In separate and detached buildings under construction, smoking is prohibited except in designated smoking rest areas.

P. Dispose of waste and debris in accordance with NFPA 241. Remove from work sites to dumpsters or other contractor provided receptacles daily.

Provide waste receptacles within work areas to prevent personal litter and food trash from accumulating on the ground.

Q. Perform other construction, alteration and demolition operations in accordance with 29 CFR 1926.

1.6 OPERATIONS AND STORAGE AREAS

A. The Contractor shall confine all operations (including storage of materials) on Government premises to areas authorized or approved by the RE/COR. The Contractor shall hold and save the Government, its officers and agents, free and harmless from liability of any nature occasioned by the Contractor's performance.

B. Temporary buildings (e.g., storage trailers, office trailers) and utilities may be erected by the Contractor only with the approval of the COR and shall be built with labor and materials furnished by the

Contractor without expense to the Government. The temporary buildings and utilities shall remain the property of the Contractor and shall be removed by the Contractor at its expense upon completion of the work.

With the written consent of the COR, the buildings and utilities may be abandoned and need not be removed.

C. The Contractor shall, under regulations prescribed by the COR, use only established roadways, or use temporary roadways constructed by the

Contractor when and as authorized by the COR. When materials are transported in prosecuting the work, vehicles shall not be loaded

NCA PROJECT NO. 817CM3025

GENERAL REQUIREMENTS

01 00 02 - 8 beyond the loading capacity recommended by the manufacturer of the vehicle or prescribed by any Federal, State, or local law or regulation. When it is necessary to cross curbs or sidewalks, the

Contractor shall protect them from damage. The Contractor shall repair or pay for the repair of any damaged curbs, sidewalks, or roads.

(FAR 52.236-10)

D. Working space and space available for storing materials shall be as determined by the COR with agreement of the Cemetery. Contractor parking will be only in areas and on roadways designated and agreed to by the RCOR in agreement of the Cemetery.

E. Workmen are subject to rules of the Cemetery applicable to their conduct.

F. Execute work so as to interfere as little as possible with normal functioning of Cemetery as a whole, including operations of utility services, fire protection systems and any existing equipment, and with work being done by others.

1. Do not store materials and equipment in other than assigned areas.

2. Provide unobstructed access to the Cemetery areas required to remain in operation.

3. Where access by Cemetery personnel to vacated portions of buildings is not required, storage of Contractor's materials and equipment will be permitted subject to fire and safety requirements. All such actions shall be coordinated with the Utility Company involved:

a. Whenever it is required that a connection fee be paid to a public utility provider for new permanent service to the construction project, for such items as water, sewer, electricity, gas or steam, payment of such fee shall be the responsibility of the contractor on behalf of the government as specified in section

1.3 of this specification.

G. Phasing: To insure such executions, the Contractor shall furnish the

COR with a schedule of approximate phasing dates on which the

Contractor intends to accomplish work in each specific area of site, building or portion thereof. In addition, the Contractor shall notify the COR two weeks in advance of the proposed date of starting work in each specific area of site, building or portion thereof. Arrange such phasing dates to insure accomplishment of this work in successive phases mutually agreeable to the Cemetery Director, COR and Contractor.

NCA PROJECT NO. 817CM3025

GENERAL REQUIREMENTS

01 00 02 - 9

H. Building 3005 will be occupied during performance of work; but immediate areas of alterations will be vacated.

1. See drawings for phasing plan.

The Contractor shall take all measures and provide all material necessary for protecting existing equipment and property in affected areas of construction against dust and debris, so that equipment and affected areas to be used in the Cemetery’s operations will not be hindered. The Contractor shall permit access to Cemetery personnel through other construction areas which serve as routes of access to such affected areas and equipment. Coordinate alteration work in areas occupied by Cemetery Staff so that Cemetery operations will continue during the construction period.

I. Construction Fence: Before construction operations begin, the

Contractor shall provide a chain link construction fence, 2.1m (seven feet) minimum height, around the construction area indicated on the drawings. Provide gates as required for access with necessary hardware, including hasps and padlocks. Fasten fence fabric to terminal posts with tension bands and to line posts and top and bottom rails with tie wires spaced at maximum 375mm (15 inches). Bottom of fences shall extend to 25mm (one inch) above grade. The temporary fencing shall encompass the construction work area(s) to serve as a pedestrian barrier to alert cemetery patrons of the construction site. Remove the fence when directed by COR.

J. When a building is turned over to Contractor, Contractor shall accept entire responsibility therefore.

1. The Contractor shall maintain a minimum temperature of 4 degrees C

(40 degrees F) at all times, except as otherwise specified.

2. The Contractor shall maintain in operating condition existing fire protection and alarm equipment. In connection with fire alarm equipment, the Contractor shall make arrangements for pre-inspection of the site with Fire Department or Company (Department of Veterans

Affairs or municipal) whichever will be required to respond to an alarm from the Contractor's employee.

K. Utilities Services: Maintain existing utility services for the Cemetery at all times. Provide temporary facilities, labor, materials, NCA PROJECT NO. 817CM3025

GENERAL REQUIREMENTS

01 00 02 - 10 equipment, connections, and utilities to assure uninterrupted services.

Where necessary to cut existing water, sewer or air pipes, or conduits, wires, cables, etc. of utility services or of fire protection systems and communications systems (including telephone), they shall be cut and capped at suitable places where shown; or, in absence of such indication, where directed by COR. All such actions shall be coordinated with the Utility Company involved.

1. No utility service such as water, gas, steam, sewers or electricity, or fire protection systems and communications systems may be interrupted without prior approval of COR. Electrical work shall be accomplished with all affected circuits or equipment de-energized.

When an electrical outage cannot be accomplished, work on any energized circuits or equipment shall not commence without the COR, and Cemetery Director’s prior knowledge and written approval. Refer to specification Sections 26 05 11, REQUIREMENTS FOR ELECTRICAL

INSTALLATIONS, 27 05 11 REQUIREMENTS FOR COMMUNICATIONS

INSTALLATIONS and 28 05 11, REQUIREMENTS FOR ELECTRONIC SAFETY AND

SECURITY INSTALLATIONS for additional requirements.

2. The Contractor shall submit a request to interrupt any such services to both COR and the Cemetery Director in writing, 48 hours in advance of proposed interruption. Request shall state reason, date, exact time of, and approximate duration of such interruption.

3. The Contractor will be advised (in writing) of approval of request, or of which other date and/or time such interruption will cause least inconvenience to operations of the Cemetery. Interruption time approved by the Cemetery and COR may occur at other than

Contractor's normal working hours.

4. Major interruptions of any system must be requested, in writing, at least 15 calendar days prior to the desired time and shall be performed as directed by the COR.

5. In case of a contract construction emergency, service will be interrupted on approval of COR. Such approval will be confirmed in writing as soon as practical.

6. Whenever it is required that a connection fee be paid to a public utility provider for new permanent service to the construction project, for such items as water, sewer, electricity, gas or steam, NCA PROJECT NO. 817CM3025

GENERAL REQUIREMENTS

01 00 02 - 11 payment of such fee shall be the responsibility of the Government and not the Contractor.

L. Abandoned Lines: All service lines such as wires, cables, conduits, ducts, pipes and the like, and their hangers or supports, which are to be abandoned but are not required to be entirely removed, shall be sealed, capped or plugged. The lines shall not be capped in finished areas, but shall be removed and sealed, capped or plugged in ceilings, within furred spaces, in unfinished areas, or within walls or partitions; so that they are completely behind the finished surfaces.

M. To minimize interference of construction activities with flow of

Cemetery traffic, comply with the following:

1. Keep roads, walks and entrances to grounds, to parking and to occupied areas of buildings clear of construction materials, debris and standing construction equipment and vehicles. Wherever excavation for new utility lines cross existing roads, at least one lane must be open to traffic at all times.

2. Method and scheduling of required cutting, altering and removal of existing roads, walks and entrances must be approved by the RE/COR.

N. Coordinate the work for this contract with other construction operations as directed by COR. This includes the scheduling of traffic and the use of roadways, as specified in Article, USE OF ROADWAYS.

O. Coordination of Construction with Cemetery Director: The burial activities at a National Cemetery shall take precedence over construction activities. The Contractor must cooperate and coordinate with the Cemetery Director, through the COR, in arranging construction schedule to cause the least possible interference with Cemetery activities in actual burial areas. Construction noise during the committal services shall not disturb the service. Trucks and workmen shall not pass through the service area during this period.

1. The Contractor is required to discontinue his work sufficiently in advance of Easter Sunday, Mother's Day, Father's Day, Memorial Day, Veteran's Day and/or Federal holidays, to permit him to clean up all areas of operation adjacent to existing burial plots before these dates.

2. Cleaning up shall include the removal of all equipment, tools, materials and debris and leaving the areas in a clean, neat condition.

NCA PROJECT NO. 817CM3025

GENERAL REQUIREMENTS

01 00 02 - 12

1.7 ALTERATIONS

A. Survey: Before any work is started, the Contractor shall make a thorough survey with the COR of buildings, areas of buildings, areas in which alterations occur, areas which are anticipated routes of access, and furnish a signed report, to the Contracting Officer. This report shall list by rooms and spaces:

1. Existing conditions and types of resilient flooring, doors, windows, walls and other surfaces not required to be altered throughout affected areas.

2. Existence and conditions of items such as plumbing fixtures and accessories, electrical fixtures, equipment, venetian blinds, shades, etc., required by drawings to be either reused or relocated, or both.

3. Shall note any discrepancies between drawings and existing conditions at site.

4. Shall designate areas for working space, materials storage and routes of access to areas within buildings where alterations occur and which have been agreed upon by Contractor and COR.

B. Any items required by drawings to be either reused or relocated or both, found during this survey to be nonexistent, or in opinion of COR, to be in such condition that their use is impossible or impractical, shall be furnished and/or replaced by the Contractor with new items in accordance with specifications which will be furnished by the

Government. Provided the contract work is changed by reason of this subparagraph B, the contract will be modified accordingly, under provisions of clause entitled "DIFFERING SITE CONDITIONS" (FAR

52.236-2) and "CHANGES" (FAR 52.243-4 and VAAR 852.236-88).

C. Re-Survey: Thirty days before expected partial or final inspection date, the Contractor and RE/COR together shall make a thorough re-survey of the areas of buildings involved. They shall furnish a report on conditions then existing, of resilient flooring, doors, windows, walls and other surfaces as compared with conditions of same as noted in first condition survey report.

1. Re-survey report shall also list any damage caused by the Contractor to such flooring and other surfaces, despite protection measures;

and, will form the basis for determining extent of repair work

NCA PROJECT NO. 817CM3025

GENERAL REQUIREMENTS

01 00 02 - 13 required of the Contractor to restore damage caused by the

Contractor's workmen in executing work of this contract.

D. Protection: Provide the following protective measures:

1. Wherever existing roof surfaces are disturbed they shall be protected against water infiltration. In case of leaks, they shall be repaired immediately upon discovery.

2. Temporary protection against damage for portions of existing structures and grounds where work is to be done, materials handled and equipment moved and/or relocated.

3. Protect the interior of existing structures at all times, from damage, dust and weather inclemency. Wherever work is performed, any surfaces that are to remain in place shall be adequately protected prior to starting work, and this protection shall be maintained intact until all work in the area is completed.

1.8 ENVIRONMENTAL CONTROLS

A. In general, following preventive measures shall be adopted during construction to keep down dust and prevent mold.

1. Dampen debris to keep down dust and provide temporary construction partitions in existing structures where directed by COR. Block off ducts and diffusers to prevent circulation of dust into occupied areas during construction.

B. Vacuum and wet mop all transition areas from construction to the occupied Cemetery buildings at the end of each workday.

C. Final Cleanup:

1. Upon completion of the project, or as work progresses, remove all construction debris from above ceiling, vertical shafts and utility chases that have been part of the construction.

2. All new air ducts shall be cleaned prior to final inspection.

1.9 DISPOSAL AND RETENTION

A. Materials and equipment accruing from work removed and from demolition of buildings or structures, or parts thereof, shall be disposed of as follows:

1. Reserved items which are to remain property of the Government are identified by attached tags, noted on drawings and/or in the specifications as items to be stored. Items that remain property of the Government shall be removed or dislodged from present locations

NCA PROJECT NO. 817CM3025

GENERAL REQUIREMENTS

01 00 02 - 14 in such a manner as to prevent damage which would be detrimental to re-installation and reuse. Store such items where directed by COR.

2. Items not reserved shall become property of the Contractor and be removed by Contractor from the Cemetery.

3. Items of portable equipment and furnishings located in rooms and spaces in which work is to be done under this contract shall remain the property of the Government. When rooms and spaces are vacated by the Department of Veterans Affairs during the alteration period, such items which are NOT required by drawings and specifications to be either relocated or reused will be removed by the Government in advance of work to avoid interfering with Contractor's operation.

4. PCB Transformers and Capacitors: The Contractor shall be responsible for disposal of the Polychlorinated Biphenyl (PCB) transformers and capacitors. The transformers and capacitors shall be taken out of service and handled in accordance with the procedures of the

Environmental Protection Agency (EPA) and the Department of

Transportation (DOT) as outlined in Code of Federal Regulation

(CFR), Titled 40 and 49 respectively. The EPA's Toxic Substance

Control Act (TSCA) Compliance Program Policy Nos. 6-PCB-6 and

6-PCB-7 also apply. Upon removal of PCB transformers and capacitors for disposal, the "originator" copy of the Uniform Hazardous Waste

Manifest (EPA Form 8700-22), along with the Uniform Hazardous Waste

Manifest Continuation Sheet (EPA Form 8700-22A) shall be returned to the RE/COTR who will annotate the contract file and transmit the

Manifest to the Cemetery's Director.

a.

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .