These are architectural drawings for the Missoula Fire Sciences Laboratory Roof Replacement project located at 5775 US Highway 10 West, Missoula, Montana. The documents detail comprehensive roof replacement plans for four building wings (A, B, C, and D), specifying precise technical requirements for the roofing work. Key specifications include removing and replacing flat roof surfaces with 60-mil EPDM membrane roofing, ensuring positive drainage, replacing expansion joints and roof drains, updating penetration and vent flashing, and applying matching PVDF factory-coated sheet metal flashing. The drawings provide detailed roof plans for each wing, showing precise measurements, roof drain locations, guardwall configurations, and structural details, with a 20-year manufacturer's warranty required for the roofing materials.
The drawings include extensive contractor instructions emphasizing site preparation, safety protocols, and environmental considerations. Notable requirements include coordinating with the Contracting Officer at least 30 days prior to construction, using 4-foot orange temporary fencing for safety, protecting existing landscaping, storing materials in the north parking area, and leaving the job site clean daily. The project is being executed by the United States Department of Agriculture Forest Service's Rocky Mountain Research Station, with drawings prepared by N. Coffman and reviewed by D. Mathews, dated January 30, 2025.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| AsbestosLeadHazMaterial- A Wing.pdf | ||
| AsbestosLeadHazMaterial- C Wing.pdf | ||
| Amendment 1240LT25R0017.pdf | ||
| Addendum 1_Fire Lab Roof Replacement.docx | DOCX document | |
| AsbestosLeadHazMaterial- B Wing.pdf | ||
| Specifications.pdf | ||
| SOW FiSL Roof Windows.docx | DOCX document | |
| Record Drawings - B-Wing Windows.pdf | ||
| Wage Determination Missoula County MT MT20250063.pdf | ||
| Record Drawings - D-Wing.pdf | ||
| 1240LT25R0017.docx | DOCX document | |
| Experience questionnaire.pdf |
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SHEET OF
United States Department of Agriculture
Forest Service
MISSOULA FIRE SCIENCES LABORATORY
3/3 /25
:5
8 N
CO
FF
MA
N C:
\U
SE
RS
\N
CO
FF
MA
N\
BO
X\
R
MR
S
EN
GI
NE
ER
IN
G\
M
IS
SO
UL
A
- A
LL
S
IT
ES
\73
F
IR
E
LA
B\
FY
G
AO
A
RO
OF
A
ND
W
IN
DO
W
R
EP
LA
CE
ME
NT
\C
AD
\F
IR
E
LA
B
RO
OF
D
RA
W
IN
GS
.D W
G;
MONTANA
MISSOULA COUNTY
(R22) ROCKY MOUNTAIN RESEARCH STATION
INDEX OF SHEETS
SHEET SHEET TITLE DATE
1 COVER SHEET 1/30/2025
2 A-WING ROOF PLAN 1/30/2025
3 B-WING ROOF PLAN 1/30/2025
4 C-WING ROOF PLAN 1/30/2025
TRAVEL DIRECTIONS:
THE PROJECT IS LOCATED AT 5775 US HWY 10 WEST, MISSOULA, MT 59808
ROOF REPLACEMENT
A
W
I
N
G
B
W
I
N
G
D
W
I
N
G
C
W
I
N
G
32'-4" 58'60'-4"
5'-0"
4'-0"
2'-0"
DRAWN
DESIGNER
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DRAWING SHEET NO.
DATENO.
REVISION / ISSUE
OFSHEET
United States Department of Agriculture Forest Service
3/3 /25
:5
8 N
CO
FF
MA
N C:
\U
SE
RS
\N
CO
FF
MA
N\
BO
X\
R
MR
S
EN
GI
NE
ER
IN
G\
M
IS
SO
UL
A
- A
LL
S
IT
ES
\73
F
IR
E
LA
B\
FY
G
AO
A
RO
OF
A
ND
W
IN
DO
W
R
EP
LA
CE
ME
NT
\C
AD
\F
IR
E
LA
B
RO
OF
D
RA
W
IN
GS
.D W
G;
(R22)
ROCKY MOUNTAIN RESEARCH STATION
MISSOULA FIRE
SCIENCES
LABORATORY
ROOF
REPLACEMENT
MISSOULA FIRE
SCIENCES LABORATORY
RMRS
A-WING ROOF PLAN
01/30/2025
N. COFFMAN
N. COFFMAN
D. MATHEWS
2 4
NOTES:
1. CONTRACTOR SHALL REMOVE AND REPLACE THE HIGHLIGHTED
COMPONENTS OF THE ROOF TO COMPLY WITH THE LATEST VERSION
OF NRCA'S ROOFING MANUAL LATEST EDITION. ELEMENTS OF THE
SCOPE INCLUDE:
1.1. REMOVE AND REPLACE FLAT ROOF SURFACE WITH 60-MIL, EPDM
MEMBRANE ROOFING WITH 20 YEAR MANUFACTURER'S
WARRANTY.
1.2. ALL ROOF AREAS MUST HAVE A POSITIVE DRAINAGE.
1.3. REMOVE AND REPLACE EXPANSION JOINTS AT THE TRANSITIONS
BETWEEN OLD AND NEW ROOFS.
1.4. REMOVE AND REPLACE REPLACE EXISTING STRAINER BASKETS
ON ALL ROOF DRAINS.
1.5. REMOVE AND REPLACE PENETRATION AND ROOF VENT FLASHING
AND BOOTS.
1.6. ALL EXPOSED SHEET METAL FLASHING WILL HAVE MATCHING
PVDF FACTORY COATING.
1.7. ANY OTHER COMPONENT REQUIRED TO PROVIDE A WATERTIGHT
ENVELOPE NOT SPECIFICALLY LISTED HERE.
2. INSTALL ALL ROOFING MATERIALS IN ACCORDANCE WITH
MANUFACTURER'S RECOMMENDATIONS.
3. EXISTING SURFACE MOUNTED ELECTRICAL AND COMMUNICATION
LINES WILL NEED TO BE REMOVED AND RESTORED TO THEIR ORIGINAL
CONDITION AFTER REPAIR, UNLESS MARKED OTHERWISE. EXISTING
CONDUIT, JUNCTION BOXES, AND MOUNTS MAY BE REUSED.
4. DURING DEMOLITION, CONTRACTOR SHALL INSPECT UNDERLAYMENT
AND INSULATION FOR DAMAGE AND SHALL REPLACE DAMAGED AREAS.
5. THE FACILITY WILL BE OCCUPIED BY US FOREST SERVICE DURING
CONSTRUCTION. COORDINATE WITH COR NO LATER THAN 30 DAYS
PRIOR TO CONSTRUCTION START. ENSURE ALL ADJACENT WALKWAYS
CONTAIN BARRIERS TO AVOID FALLING DEBRIS MISHAPS. USE 4FT
PLASTIC ORANGE TEMPORARY FENCING IN ACCORDANCE WITH OSHA
29 CFR 1926 SUBPART M.
6. AN EXTENSIVE EFFORT HAS BEEN MADE TO LOCATE ALL POSSIBLE
EXISTING ROOF PENETRATIONS AND ROOF-MOUNTED EQUIPMENT
FROM RECORDS AND EVIDENCE IN THE FIELD, HOWEVER, THE
COMPLETENESS OR ACCURACY OF THE LOCATIONS SHOWN CANNOT
BE GUARANTEED. THE CONTRACTOR IS RESPONSIBLE FOR
ESTABLISHING THE LOCATION OF ALL ROOFTOP FEATURES. ANY
LOCATION SHOWN IS APPROXIMATE. IF CONFLICTS ARE FOUND,
NOTIFY THE CONTRACTING OFFICER.
7. CONTRACTOR SHALL VERIFY ALL QUANTITIES AND DIMENSIONS PRIOR
TO ORDERING MATERIALS.
8. CONTRACTOR SHALL LEAVE THE JOB SITE CLEAN AT THE END OF EACH
WORKING DAY. ALL MATERIALS SHALL BE STORED IN A NEAT AND SAFE
PLACE TO PREVENT MISHAPS. CONTRACTOR STAGING AREA AND
MATERIAL STORAGE SHALL BE CONFINED TO THE NORTH PARKING
AREA.
9. PROTECT EXISTING LANDSCAPING AND VEGETATION TO THE MAXIMUM
EXTENT POSSIBLE. IF THE CONTRACTOR MUST DRIVE OVER
LANDSCAPED AREA TO ACCESS AREAS OF THE ROOF, USE PLYWOOD
OR OSB UNDER WHEEL PATHS TO PREVENT RUTTING. IF DAMAGE TO
LANDSCAPING OCCURS DUE TO CONSTRUCTION ACTIVITIES,
CONTRACTOR SHALL REPAIR AT NO ADDITIONAL COST TO THE
GOVERNMENT.
10. CONTRACTOR SHALL INSTALL ALL MATERIALS SPECIFIED ACCORDING
TO MANUFACTURER'S RECOMMENDATIONS UNLESS OTHERWISE
SPECIFIED. ALL GUARANTEES, INSTRUCTION BOOKLETS, EXTENDED
WORKMANSHIP WARRANTIES, MATERIAL WARRANTIES AND
INFORMATION REGARDING MATERIALS USED SHALL BE DELIVERED TO
THE COR VIA EMAIL PRIOR TO CONSTRUCTION START.
ABBREVIATIONS:
AB = ABANDONED
CONC = CONCRETE
COND = CONDUIT
LF = LINEAL FEET
PVRS = PAVERS
REFRIG = REFRIGERANT
SF = SQUARE FEET
AutoCAD SHX Text
VENTILATOR
AutoCAD SHX Text
GROUND LINE
AutoCAD SHX Text
SCALE 1/8" = 1' 0"
AutoCAD SHX Text 16'
AutoCAD SHX Text 8'
AutoCAD SHX Text 4'
AutoCAD SHX Text 2'
AutoCAD SHX Text
AutoCAD SHX Text 2'
AutoCAD SHX Text
%%UPROFILE OF A-WING
AutoCAD SHX Text
%%UPLAN VIEW OF A-WING ROOF
AutoCAD SHX Text
SCALE 1/8" = 1' 0"
AutoCAD SHX Text 16'
AutoCAD SHX Text 8'
AutoCAD SHX Text 4'
AutoCAD SHX Text 2'
AutoCAD SHX Text
AutoCAD SHX Text 2'
AutoCAD SHX Text
%%UEXISTING ROOF STRUCTURE
AutoCAD SHX Text
LIGHTWEIGHT CONCRETE
AutoCAD SHX Text
1 1/2" RIGID INSULATION
AutoCAD SHX Text
1" MINERAL UNDERLAYMENT
AutoCAD SHX Text
EPDM MEMBRANE
AutoCAD SHX Text
1" COND
AutoCAD SHX Text
(6) 4" VENTS
AutoCAD SHX Text
(5) 3" INSULATED REFRIG LINES
AutoCAD SHX Text
ROOF DRAIN
AutoCAD SHX Text
ROOF DRAIN
AutoCAD SHX Text
ROOF DRAIN
AutoCAD SHX Text
STONE BALLAST
AutoCAD SHX Text
CONCRETE CURB
AutoCAD SHX Text
3" PIPE
AutoCAD SHX Text
5" PIPE
AutoCAD SHX Text
ROOF DRAIN
AutoCAD SHX Text
1 " COND12" COND
AutoCAD SHX Text
1 " 12" COND
AutoCAD SHX Text
1 " COND12" COND
AutoCAD SHX Text
COND
AutoCAD SHX Text
(3) 4" VENTS
AutoCAD SHX Text
2" COND
AutoCAD SHX Text
2" PIPE
AutoCAD SHX Text
(3) COND
AutoCAD SHX Text
6" SUPPORTS
AutoCAD SHX Text
BILCO S-20 ROOF HATCH
AutoCAD SHX Text
20 LF GUARDRAIL
AutoCAD SHX Text
22 LF GUARDRAIL
AutoCAD SHX Text
18 LF GUARDRAIL
AutoCAD SHX Text
6 LF GUARDRAIL
AutoCAD SHX Text
6 LF GUARDRAIL
AutoCAD SHX Text
EXISTING 8" GRAVEL STOP
AutoCAD SHX Text
PARAPET WALL - 3 SIDES
AutoCAD SHX Text
57 LF GUARDRAIL
AutoCAD SHX Text
14 LF GUARDRAIL
AutoCAD SHX Text
24 LF GUARDRAIL
AutoCAD SHX Text
68 SF CONC PVRS
AutoCAD SHX Text
63 SF CONC PVRS
AutoCAD SHX Text
227 SF CONC PVRS
AutoCAD SHX Text
264 SF CONC PVRS
AutoCAD SHX Text
HATCH GUARDRAIL
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text V
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text P
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text T
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text T
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text T
AutoCAD SHX Text U
AutoCAD SHX Text R
AutoCAD SHX Text E
193'-5"
STAIRS TO SECOND
STORY CATWALK
DRAWN
DESIGNER
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DRAWING SHEET NO.
DATENO.
REVISION / ISSUE
OFSHEET
United States Department of Agriculture Forest Service
3/3 /25
:5
8 N
CO
FF
MA
N C:
\U
SE
RS
\N
CO
FF
MA
N\
BO
X\
R
MR
S
EN
GI
NE
ER
IN
G\
M
IS
SO
UL
A
- A
LL
S
IT
ES
\73
F
IR
E
LA
B\
FY
G
AO
A
RO
OF
A
ND
W
IN
DO
W
R
EP
LA
CE
ME
NT
\C
AD
\F
IR
E
LA
B
RO
OF
D
RA
W
IN
GS
.D W
G;
(R22)
ROCKY MOUNTAIN RESEARCH STATION
MISSOULA FIRE
SCIENCES
LABORATORY
ROOF
REPLACEMENT
MISSOULA FIRE
SCIENCES LABORATORY
RMRS
B-WING ROOF PLAN
01/30/2025
N. COFFMAN
N. COFFMAN
D. MATHEWS
3 4
NOTES:
1. CONTRACTOR SHALL REMOVE AND REPLACE THE HIGHLIGHTED COMPONENTS OF THE ROOF TO COMPLY WITH
THE LATEST VERSION OF NRCA'S ROOFING MANUAL LATEST EDITION. ELEMENTS OF THE SCOPE INCLUDE:
1.1. REMOVE AND REPLACE FLAT ROOF SURFACE WITH 60-MIL, EPDM MEMBRANE ROOFING WITH 20 YEAR
MANUFACTURER'S WARRANTY.
1.2. ALL ROOF AREAS MUST HAVE A POSITIVE DRAINAGE.
1.3. REMOVE AND REPLACE EXPANSION JOINTS AT THE TRANSITIONS BETWEEN OLD AND NEW ROOFS.
1.4. REMOVE AND REPLACE REPLACE EXISTING STRAINER BASKETS ON ALL ROOF DRAINS.
1.5. REMOVE AND REPLACE PENETRATION AND ROOF VENT FLASHING AND BOOTS.
1.6. ALL EXPOSED SHEET METAL FLASHING WILL HAVE MATCHING PVDF FACTORY COATING.
1.7. ANY OTHER COMPONENT REQUIRED TO PROVIDE A WATERTIGHT ENVELOPE NOT SPECIFICALLY LISTED
HERE.
2. INSTALL ALL ROOFING MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS.
3. EXISTING SURFACE MOUNTED ELECTRICAL AND COMMUNICATION LINES WILL NEED TO BE REMOVED AND
RESTORED TO THEIR ORIGINAL CONDITION AFTER REPAIR, UNLESS MARKED OTHERWISE. EXISTING CONDUIT, JUNCTION BOXES, AND MOUNTS MAY BE REUSED.
4. DURING DEMOLITION, CONTRACTOR SHALL INSPECT UNDERLAYMENT AND INSULATION FOR DAMAGE AND
SHALL REPLACE DAMAGED AREAS.
5. THE FACILITY WILL BE OCCUPIED BY US FOREST SERVICE DURING CONSTRUCTION. COORDINATE WITH COR
NO LATER THAN 30 DAYS PRIOR TO CONSTRUCTION START. ENSURE ALL ADJACENT WALKWAYS CONTAIN
BARRIERS TO AVOID FALLING DEBRIS MISHAPS. USE 4FT PLASTIC ORANGE TEMPORARY FENCING IN
ACCORDANCE WITH OSHA 29 CFR 1926 SUBPART M.
6. AN EXTENSIVE EFFORT HAS BEEN MADE TO LOCATE ALL POSSIBLE EXISTING ROOF PENETRATIONS AND
ROOF-MOUNTED EQUIPMENT FROM RECORDS AND EVIDENCE IN THE FIELD, HOWEVER, THE COMPLETENESS
OR ACCURACY OF THE LOCATIONS SHOWN CANNOT BE GUARANTEED. THE CONTRACTOR IS RESPONSIBLE
FOR ESTABLISHING THE LOCATION OF ALL ROOFTOP FEATURES. ANY LOCATION SHOWN IS APPROXIMATE. IF
CONFLICTS ARE FOUND, NOTIFY THE CONTRACTING OFFICER.
7. CONTRACTOR SHALL VERIFY ALL QUANTITIES AND DIMENSIONS PRIOR TO ORDERING MATERIALS.
8. CONTRACTOR SHALL LEAVE THE JOB SITE CLEAN AT THE END OF EACH WORKING DAY. ALL MATERIALS SHALL
BE STORED IN A NEAT AND SAFE PLACE TO PREVENT MISHAPS. CONTRACTOR STAGING AREA AND MATERIAL
STORAGE SHALL BE CONFINED TO THE NORTH PARKING AREA.
9. PROTECT EXISTING LANDSCAPING AND VEGETATION TO THE MAXIMUM EXTENT POSSIBLE. IF THE
CONTRACTOR MUST DRIVE OVER LANDSCAPED AREA TO ACCESS AREAS OF THE ROOF, USE PLYWOOD OR
OSB UNDER WHEEL PATHS TO PREVENT RUTTING. IF DAMAGE TO LANDSCAPING OCCURS DUE TO
CONSTRUCTION ACTIVITIES, CONTRACTOR SHALL REPAIR AT NO ADDITIONAL COST TO THE GOVERNMENT.
10. CONTRACTOR SHALL INSTALL ALL MATERIALS SPECIFIED ACCORDING TO MANUFACTURER'S
RECOMMENDATIONS UNLESS OTHERWISE SPECIFIED. ALL GUARANTEES, INSTRUCTION BOOKLETS, EXTENDED
WORKMANSHIP WARRANTIES, MATERIAL WARRANTIES AND INFORMATION REGARDING MATERIALS USED
SHALL BE DELIVERED TO THE COR VIA EMAIL PRIOR TO CONSTRUCTION START.
ABBREVIATIONS:
AB = ABANDONED
CONC = CONCRETE
COND = CONDUIT
LF = LINEAL FEET
PVRS = PAVERS
REFRIG = REFRIGERANT
SF = SQUARE FEET
AutoCAD SHX Text
%%UPLAN VIEW OF B-WING ROOF
AutoCAD SHX Text
2" PIPE
AutoCAD SHX Text
4" PIPE
AutoCAD SHX Text
2" COND
AutoCAD SHX Text
2" PIPE
AutoCAD SHX Text
3" PIPE
AutoCAD SHX Text
12" COND
AutoCAD SHX Text
ROOF DRAIN
AutoCAD SHX Text
ROOF DRAIN
AutoCAD SHX Text
ROOF DRAIN
AutoCAD SHX Text
1 " PIPE12" PIPE
AutoCAD SHX Text
2" PIPE
AutoCAD SHX Text
4" VENT
AutoCAD SHX Text
2" PIPE
AutoCAD SHX Text
1" PIPE
AutoCAD SHX Text
4" PIPE
AutoCAD SHX Text
2" PIPE
AutoCAD SHX Text
6 LF GUARDRAIL
AutoCAD SHX Text
12 LF GUARDRAIL
AutoCAD SHX Text
SCALE 1/8" = 1' 0"
AutoCAD SHX Text 16'
AutoCAD SHX Text 8'
AutoCAD SHX Text 4'
AutoCAD SHX Text 2'
AutoCAD SHX Text
AutoCAD SHX Text 2'
AutoCAD SHX Text
195 SF CONC PVRS
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text V
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text P
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text T
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text T
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text T
AutoCAD SHX Text U
AutoCAD SHX Text R
33'-9"
2'-0"
DRAWN
DESIGNER
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DRAWING SHEET NO.
DATENO.
REVISION / ISSUE
OFSHEET
United States Department of Agriculture Forest Service
3/3 /25
:5
8 N
CO
FF
MA
N C:
\U
SE
RS
\N
CO
FF
MA
N\
BO
X\
R
MR
S
EN
GI
NE
ER
IN
G\
M
IS
SO
UL
A
- A
LL
S
IT
ES
\73
F
IR
E
LA
B\
FY
G
AO
A
RO
OF
A
ND
W
IN
DO
W
R
EP
LA
CE
ME
NT
\C
AD
\F
IR
E
LA
B
RO
OF
D
RA
W
IN
GS
.D W
G;
(R22)
ROCKY MOUNTAIN RESEARCH STATION
MISSOULA FIRE
SCIENCES
LABORATORY
ROOF
REPLACEMENT
MISSOULA FIRE
SCIENCES LABORATORY
RMRS
C-WING ROOF PLAN
01/30/2025
N. COFFMAN
N. COFFMAN
D. MATHEWS
4 4
NOTES:
1. CONTRACTOR SHALL REMOVE AND REPLACE THE HIGHLIGHTED
COMPONENTS OF THE ROOF TO COMPLY WITH THE LATEST VERSION
OF NRCA'S ROOFING MANUAL LATEST EDITION. ELEMENTS OF THE
SCOPE INCLUDE:
1.1. REMOVE AND REPLACE FLAT ROOF SURFACE WITH 60-MIL, EPDM
MEMBRANE ROOFING WITH 20 YEAR MANUFACTURER'S
WARRANTY.
1.2. ALL ROOF AREAS MUST HAVE A POSITIVE DRAINAGE.
1.3. REMOVE AND REPLACE EXPANSION JOINTS AT THE TRANSITIONS
BETWEEN OLD AND NEW ROOFS.
1.4. REMOVE AND REPLACE REPLACE EXISTING STRAINER BASKETS
ON ALL ROOF DRAINS.
1.5. REMOVE AND REPLACE PENETRATION AND ROOF VENT FLASHING
AND BOOTS.
1.6. ALL EXPOSED SHEET METAL FLASHING WILL HAVE MATCHING
PVDF FACTORY COATING.
1.7. ANY OTHER COMPONENT REQUIRED TO PROVIDE A WATERTIGHT
ENVELOPE NOT SPECIFICALLY LISTED HERE.
2. INSTALL ALL ROOFING MATERIALS IN ACCORDANCE WITH
MANUFACTURER'S RECOMMENDATIONS.
3. EXISTING SURFACE MOUNTED ELECTRICAL AND COMMUNICATION
LINES WILL NEED TO BE REMOVED AND RESTORED TO THEIR ORIGINAL
CONDITION AFTER REPAIR, UNLESS MARKED OTHERWISE. EXISTING
CONDUIT, JUNCTION BOXES, AND MOUNTS MAY BE REUSED.
4. DURING DEMOLITION, CONTRACTOR SHALL INSPECT UNDERLAYMENT
AND INSULATION FOR DAMAGE AND SHALL REPLACE DAMAGED AREAS.
5. THE FACILITY WILL BE OCCUPIED BY US FOREST SERVICE DURING
CONSTRUCTION. COORDINATE WITH COR NO LATER THAN 30 DAYS
PRIOR TO CONSTRUCTION START. ENSURE ALL ADJACENT WALKWAYS
CONTAIN BARRIERS TO AVOID FALLING DEBRIS MISHAPS. USE 4FT
PLASTIC ORANGE TEMPORARY FENCING IN ACCORDANCE WITH OSHA
29 CFR 1926 SUBPART M.
6. AN EXTENSIVE EFFORT HAS BEEN MADE TO LOCATE ALL POSSIBLE
EXISTING ROOF PENETRATIONS AND ROOF-MOUNTED EQUIPMENT
FROM RECORDS AND EVIDENCE IN THE FIELD, HOWEVER, THE
COMPLETENESS OR ACCURACY OF THE LOCATIONS SHOWN CANNOT
BE GUARANTEED. THE CONTRACTOR IS RESPONSIBLE FOR
ESTABLISHING THE LOCATION OF ALL ROOFTOP FEATURES. ANY
LOCATION SHOWN IS APPROXIMATE. IF CONFLICTS ARE FOUND,
NOTIFY THE CONTRACTING OFFICER.
7. CONTRACTOR SHALL VERIFY ALL QUANTITIES AND DIMENSIONS PRIOR
TO ORDERING MATERIALS.
8. CONTRACTOR SHALL LEAVE THE JOB SITE CLEAN AT THE END OF EACH
WORKING DAY. ALL MATERIALS SHALL BE STORED IN A NEAT AND SAFE
PLACE TO PREVENT MISHAPS. CONTRACTOR STAGING AREA AND
MATERIAL STORAGE SHALL BE CONFINED TO THE NORTH PARKING
AREA.
9. PROTECT EXISTING LANDSCAPING AND VEGETATION TO THE MAXIMUM
EXTENT POSSIBLE. IF THE CONTRACTOR MUST DRIVE OVER
LANDSCAPED AREA TO ACCESS AREAS OF THE ROOF, USE PLYWOOD
OR OSB UNDER WHEEL PATHS TO PREVENT RUTTING. IF DAMAGE TO
LANDSCAPING OCCURS DUE TO CONSTRUCTION ACTIVITIES,
CONTRACTOR SHALL REPAIR AT NO ADDITIONAL COST TO THE
GOVERNMENT.
10. CONTRACTOR SHALL INSTALL ALL MATERIALS SPECIFIED ACCORDING
TO MANUFACTURER'S RECOMMENDATIONS UNLESS OTHERWISE
SPECIFIED. ALL GUARANTEES, INSTRUCTION BOOKLETS, EXTENDED
WORKMANSHIP WARRANTIES, MATERIAL WARRANTIES AND
INFORMATION REGARDING MATERIALS USED SHALL BE DELIVERED TO
THE COR VIA EMAIL PRIOR TO CONSTRUCTION START.
ABBREVIATIONS:
AB = ABANDONED
CONC = CONCRETE
COND = CONDUIT
LF = LINEAL FEET
PVRS = PAVERS
REFRIG = REFRIGERANT
SF = SQUARE FEET
AutoCAD SHX Text
%%UPLAN VIEW OF C-WING ROOF
AutoCAD SHX Text
4" PIPE
AutoCAD SHX Text
AB 1" COND
AutoCAD SHX Text
ROOF DRAIN
AutoCAD SHX Text
AB " 34" COND
AutoCAD SHX Text
1 " 12" COND
AutoCAD SHX Text
AB 1 " COND12" COND
AutoCAD SHX Text
4" PIPE
AutoCAD SHX Text
2" COND
AutoCAD SHX Text
34" COND.
AutoCAD SHX Text
1 " 12" COND
AutoCAD SHX Text
34" COND
AutoCAD SHX Text
1 " 12" PIPE
AutoCAD SHX Text
10 LF GUARDRAIL
AutoCAD SHX Text
42 LF GUARDRAIL
AutoCAD SHX Text
SCALE 1/4" = 1' 0"
AutoCAD SHX Text 8'
AutoCAD SHX Text 4'
AutoCAD SHX Text 2'
AutoCAD SHX Text 1'
AutoCAD SHX Text
AutoCAD SHX Text 1'
AutoCAD SHX Text
149 SF CONC PVRS
AutoCAD SHX Text
STAIRS TO CATWALK
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text V
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text P
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text T
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text T
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text T
AutoCAD SHX Text U
AutoCAD SHX Text R
| Sheets and Views |
| Fire Lab Roof Drawings-Cover |
| Fire Lab Roof Drawings-A-Wing |
| Fire Lab Roof Drawings-B-Wing |
| Fire Lab Roof Drawings-C-Wing |
File details come from the government source that posted it. Updated .