Drawings 5 of 9.pdf
PDF 2 MB Posted
- Solicitation number
- 36C24222B0077
About this file
This package of construction documents outlines plans to improve the potable water distribution system at the VA New York Healthcare System campus located in Batavia, New York. The project involves upgrading piping infrastructure across multiple buildings on the campus, including the replacement of water fountains with bottle fillers. Drawings show existing conditions and demolition plans for buildings 2 through 6, the transitional work dormitory, and facilities 11, 30 and administrative building 15. Enlarged plans provide details for specific rooms undergoing renovations. The solicitation number is 36C24222B0077 and relates to contract number 528A4-16-205 to improve infrastructure at the VA medical center campus located at 222 Richmond Avenue, Batavia, New York 14020.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Sign in Sheet_11.04.22.pdf | ||
| 36C24222B0077 0003.pdf | ||
| Sign in Sheet_10.18.22.pdf | ||
| Key Points Pre Bid Solicitation_10.18.22.pdf | ||
| 36C24222B0077 0002.pdf | ||
| 36C24222B0077 0001.docx | DOCX document | |
| Specs 1 of 10.pdf | ||
| Specs 4 of 10.pdf | ||
| Specs 2 of 10.pdf | ||
| Specs 9 of 10.pdf | ||
| Drawings 9 of 9.pdf | ||
| Specs 7 of 10.pdf | ||
| Specs 8 of 10.pdf | ||
| Drawings 1 of 9.pdf | ||
| VHA Supplemental Contract Requirements for Ensuring Adequate COVID-19 Safety Protocols for Federal Contractors rev2.docx | DOCX document | |
| Specs 5 of 10.pdf | ||
| Drawings 3 of 9.pdf | ||
| Specs 10 of 10.pdf | ||
| Specs 6 of 10.pdf | ||
| Drawings 6 of 9.pdf | ||
| Drawings 8 of 9.pdf | ||
| 36C24222B0077.docx | DOCX document | |
| Drawings 2 of 9.pdf | ||
| Drawings 7 of 9.pdf | ||
| Specs 3 of 10.pdf | ||
| Drawings 4 of 9.pdf |
Show all 26
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h 6/
/2
:3
9:
P M
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
IMPROVE POTABLE WATER
DISTRIBUTION SYSTEM
222 RICHMOND AVENUE
BATAVIA, NY 14020
528A4-16-205
Project Director
06/08/2022Revisions: Date:
PL-114
D.L.E.
VA NEW YORK
HEALTHCARE SYSTEM
CONSTRUCTION DOCUMENTS
34 BROWN STREET
HONESDALE, PA 18431
OFFICE : (570) 253-0846
FAX : (570) 253-1935
WWW.NEINFRA.COM
NORTHEAST INFRASTRUCTURE, LLC
BUILDING 2 GROUND FLOOR
EXISITING CONDITIONS/DEMOLITION
ENLARGED PLUMBING PLANS
F.R.O.
AutoCAD SHX Text G17
AutoCAD SHX Text G16
AutoCAD SHX Text
3" CW MAIN
AutoCAD SHX Text
2" CW MAIN
AutoCAD SHX Text 2-G-16A-004-A
AutoCAD SHX Text 2-G-16A-007-A
AutoCAD SHX Text
2" CW
AutoCAD SHX Text
3/4" CW,HW
AutoCAD SHX Text 2-G-17-002-A
AutoCAD SHX Text 2-G-17-001-A
AutoCAD SHX Text
1/2" CW,HW
AutoCAD SHX Text
1/2" CW
AutoCAD SHX Text 2-G-16-001-A
AutoCAD SHX Text
WATER SOFTENER BLEND VALVE
AutoCAD SHX Text
WATER HEATER
AutoCAD SHX Text
1/2" CW,HW
AutoCAD SHX Text
NI-18
AutoCAD SHX Text 2-G-11-002-A
AutoCAD SHX Text
NI-16
AutoCAD SHX Text
NI-19
AutoCAD SHX Text
NI-17
AutoCAD SHX Text
AI-4
AutoCAD SHX Text
3/4" CW,HW
AutoCAD SHX Text
1/2" CW,HW
AutoCAD SHX Text
1/2" CW TO EQUIP
AutoCAD SHX Text
3/4" CW,HW
AutoCAD SHX Text
1 1/4" HW 1" HWR
AutoCAD SHX Text
1" HWR
AutoCAD SHX Text
1 1/4" HW
AutoCAD SHX Text
2" CW
AutoCAD SHX Text
2" CW
AutoCAD SHX Text G14
AutoCAD SHX Text G11
AutoCAD SHX Text
TO EQUIP
AutoCAD SHX Text
TO EQUIP
AutoCAD SHX Text
G16A MECH
AutoCAD SHX Text G16A-004
AutoCAD SHX Text 2-G
AutoCAD SHX Text 2-G-16A-006-A
AutoCAD SHX Text
1 1/4" HW
AutoCAD SHX Text 2-G-16-002-A
AutoCAD SHX Text G16-002
AutoCAD SHX Text 2-G
AutoCAD SHX Text
NC
AutoCAD SHX Text G17-001
AutoCAD SHX Text 2-G
AutoCAD SHX Text
WATER SOFTENER
AutoCAD SHX Text 2-G-11-001-A
AutoCAD SHX Text
3/4" CW
AutoCAD SHX Text
1/2" CW
AutoCAD SHX Text G18
AutoCAD SHX Text
1/2" CW
AutoCAD SHX Text
1/2" HW
AutoCAD SHX Text
1" CW
AutoCAD SHX Text
1" CW
AutoCAD SHX Text
1/2" HW
AutoCAD SHX Text
1/2" CW,HW
AutoCAD SHX Text
1 1/4" CW(TYP)
AutoCAD SHX Text 2-G-22B-001-A
AutoCAD SHX Text
1/2" CW,HW (TYP)
AutoCAD SHX Text
1 1/2" CW
AutoCAD SHX Text
3/4" HW
AutoCAD SHX Text
1" HWR
AutoCAD SHX Text
1" HW
AutoCAD SHX Text
1" HWR
AutoCAD SHX Text
1" HW
AutoCAD SHX Text
1 1/2" CW
AutoCAD SHX Text
3/4" HW
AutoCAD SHX Text G22B
AutoCAD SHX Text
1/2" CW,HW (TYP)
AutoCAD SHX Text
PLUMBING FIELD STUDY KEY SYMBOLS
AutoCAD SHX Text TYPE A - PIPE LENGTH GREATER THAN TWICE THE DIAMETER OF THE PIPE SIZE TERMINATING AT CAP, VALVE, OR FITTING.
AutoCAD SHX Text TYPE B - PIPE LENGTH GREATER THAN TWICE THE DIAMETER OF THE PIPES TERMINATING AT AN INFREQUENTLY USED PLUMBING FIXTURE.
AutoCAD SHX Text TYPE C - PIPE LENGTH GREATER THAN 25 FEET TERMINATING AT A FREQUENTLY USED PLUMBING FIXTURE
AutoCAD SHX Text
DEAD LEG TAG
AutoCAD SHX Text
BACK FLOW PREVENTER TAG
AutoCAD SHX Text
CROSS-CONNECTION TAG
AutoCAD SHX Text
REMEDIATE DEAD LEG
AutoCAD SHX Text
NON-INSULATED PIPE REFER TO SCHEDULE
AutoCAD SHX Text
XXX-XX-XXX-XXX
AutoCAD SHX Text
XXX-XX-XXX-XXX
AutoCAD SHX Text
XXX-XXX
AutoCAD SHX Text
XX-XX
AutoCAD SHX Text
NI-X
AutoCAD SHX Text
ENLARGED PLAN PLUMBING LINE TYPES
AutoCAD SHX Text
COLD WATER
AutoCAD SHX Text
HOT WATER
AutoCAD SHX Text
HOT WATER RETURN
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
EXISTING CONDITIONS/DEMOLITION ENLARGED PLUMBING PLAN
AutoCAD SHX Text 1/2"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
BUILDING 2 GROUND FLOOR ROOMS G11 TO G17
AutoCAD SHX Text
PL-114
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
CONDITIONS/DEMOLITION ENLARGED PLUMBING PLAN
AutoCAD SHX Text 1/2"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
BUILDING 2 GROUND FLOOR ROOM G18 EXISTING
AutoCAD SHX Text
PL-114
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
CONDITIONS/DEMOLITION ENLARGED PLUMBING PLAN
AutoCAD SHX Text 1/2"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
BUILDING 2 GROUND FLOOR ROOM G22B EXISTING
AutoCAD SHX Text
PL-114
AutoCAD SHX Text N
AutoCAD SHX Text
PROJECT NORTH
AutoCAD SHX Text N
AutoCAD SHX Text
PROJECT NORTH
AutoCAD SHX Text N
AutoCAD SHX Text
PROJECT NORTH
AutoCAD SHX Text
SMOKE RESISTANT BARRIER
AutoCAD SHX Text
30 MINUTE SMOKE BARRIER
AutoCAD SHX Text
1 HOUR FIRE/SMOKE BARRIER
AutoCAD SHX Text
2 HOUR FIRE/SMOKE BARRIER
AutoCAD SHX Text
1 HOUR FIRE BARRIER
AutoCAD SHX Text
2 HOUR FIRE BARRIER
AutoCAD SHX Text
3 HOUR FIRE BARRIER
AutoCAD SHX Text
FIRE BARRIER LINETYPES
AutoCAD SHX Text
ENLARGED PLAN LOCATION SCHEDULE:
AutoCAD SHX Text
1/PL-114
AutoCAD SHX Text
SEE DRAWING 1/PL-113
AutoCAD SHX Text
2/PL-114
AutoCAD SHX Text
SEE DRAWING 1/PL-113
AutoCAD SHX Text
3/PL-114
AutoCAD SHX Text
SEE DRAWING 1/PL-113
AutoCAD SHX Text
GENERAL NOTES:
AutoCAD SHX Text 1.
AutoCAD SHX Text PLUMBING DRAWINGS ARE BASED ON OBSERVED AS-BUILT CONDITIONS. NOT ALL PIPING IS ACCESSIBLE. IN CASE WORK IS TO BE COMPLETED WITHIN AN INACCESSIBLE AREA, CONTRACTOR SHALL VERIFY PIPE SIZE, LENGTH, ROUTING, END POINT, AND ORIGIN OF ANY PIPING THAT CONTINUES INTO AN INACCESSIBLE AREA PRIOR TO START OF WORK.
AutoCAD SHX Text 2.
AutoCAD SHX Text ALL DOMESTIC WATER SHALL BE RESTORED TO ORIGINAL CONDITION UPON COMPLETION OF WORKDAY. THIS INCLUDES ALL SHIFTS AND SHUTDOWNS REQUIRED. ALL SHUTDOWNS SHALL BE COORDINATED WITH COR PRIOR TO START OF WORK. CONTRACTOR SHALL PROVIDE SCHEDULE OF ALL SHUTDOWNS AND EXPECTED DOWN TIMES TO COR FOR REVIEW BEFORE INITIATING WORK.
AutoCAD SHX Text 3.
AutoCAD SHX Text CONTRACTOR SHALL REVIEW AND ENSURE ALL WORK IS COMPLETED IN ACCORDANCE WITH THE GENERAL FIRE RATED BARRIER NOTES ON PL-001.
AutoCAD SHX Text
NOTE: NO DEMO WORK SHALL BE COMPLETED WITHIN PLAN 1/PL-114.
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h 6/
/2
:3
9:
P M
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
IMPROVE POTABLE WATER
DISTRIBUTION SYSTEM
222 RICHMOND AVENUE
BATAVIA, NY 14020
528A4-16-205
Project Director
06/08/2022Revisions: Date:
PL-115
D.L.E.
VA NEW YORK
HEALTHCARE SYSTEM
CONSTRUCTION DOCUMENTS
34 BROWN STREET
HONESDALE, PA 18431
OFFICE : (570) 253-0846
FAX : (570) 253-1935
WWW.NEINFRA.COM
NORTHEAST INFRASTRUCTURE, LLC
BUILDING 2 GROUND FLOOR
EXISITING CONDITIONS/DEMOLITION
ENLARGED PLUMBING PLAN AND ELEVATION
F.R.O.
AutoCAD SHX Text
1" CW
AutoCAD SHX Text
1" HW
AutoCAD SHX Text
1/2" HWR 1" HW
AutoCAD SHX Text
1/2" CW,HW
AutoCAD SHX Text
2-G-CORR-005-A
AutoCAD SHX Text
1" HW,HWR
AutoCAD SHX Text
1 1/2" CW 3/4" HW
AutoCAD SHX Text
1" CW
AutoCAD SHX Text
1 1/4" CW(TYP)
AutoCAD SHX Text
1" HW
AutoCAD SHX Text
1" HW
AutoCAD SHX Text
3/4" HWR
AutoCAD SHX Text
1" CW
AutoCAD SHX Text
2" CW 1 1/4" HW 1" HWR
AutoCAD SHX Text
2" CW 1 1/4" HW 1" HWR
AutoCAD SHX Text
3/4" CW,HW
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
1/2" HWR
AutoCAD SHX Text
3/4" CW,HW
AutoCAD SHX Text
1" CW
AutoCAD SHX Text
3/4" HW
AutoCAD SHX Text
1/2" HWR
AutoCAD SHX Text
1" CW,HW
AutoCAD SHX Text
PL-115
AutoCAD SHX Text
AutoCAD SHX Text
2-G-CORR-003-A
AutoCAD SHX Text
2" CW
AutoCAD SHX Text
2-G-CORR-010-A
AutoCAD SHX Text
2-G-CORR-011-A
AutoCAD SHX Text
2-G-CORR-008-A
AutoCAD SHX Text
2-G-CORR-009-A
AutoCAD SHX Text G14
AutoCAD SHX Text
1" HW
AutoCAD SHX Text
1/2" CW
AutoCAD SHX Text
1/2" HW
AutoCAD SHX Text
1/2" CW
AutoCAD SHX Text
AutoCAD SHX Text
ACM
AutoCAD SHX Text
ACM
AutoCAD SHX Text
ACM
AutoCAD SHX Text
EYEWASH
AutoCAD SHX Text
NI-20
AutoCAD SHX Text
NI-21
AutoCAD SHX Text
PLUMBING FIELD STUDY KEY SYMBOLS
AutoCAD SHX Text TYPE A - PIPE LENGTH GREATER THAN TWICE THE DIAMETER OF THE PIPE SIZE TERMINATING AT CAP, VALVE, OR FITTING.
AutoCAD SHX Text TYPE B - PIPE LENGTH GREATER THAN TWICE THE DIAMETER OF THE PIPES TERMINATING AT AN INFREQUENTLY USED PLUMBING FIXTURE.
AutoCAD SHX Text TYPE C - PIPE LENGTH GREATER THAN 25 FEET TERMINATING AT A FREQUENTLY USED PLUMBING FIXTURE
AutoCAD SHX Text
DEAD LEG TAG
AutoCAD SHX Text
BACK FLOW PREVENTER TAG
AutoCAD SHX Text
CROSS-CONNECTION TAG
AutoCAD SHX Text
REMEDIATE DEAD LEG
AutoCAD SHX Text
NON-INSULATED PIPE REFER TO SCHEDULE
AutoCAD SHX Text
XXX-XX-XXX-XXX
AutoCAD SHX Text
XXX-XX-XXX-XXX
AutoCAD SHX Text
XXX-XXX
AutoCAD SHX Text
XX-XX
AutoCAD SHX Text
NI-X
AutoCAD SHX Text
ENLARGED PLAN PLUMBING LINE TYPES
AutoCAD SHX Text
COLD WATER
AutoCAD SHX Text
HOT WATER
AutoCAD SHX Text
HOT WATER RETURN
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
CONDITIONS/DEMOLITION ENLARGED PLUMBING PLAN
AutoCAD SHX Text 1/2"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
BUILDING 2 GROUND FLOOR CORRIDOR EXISTING
AutoCAD SHX Text
PL-115
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
CONDITIONS/DEMOLITION PLUMBING ELEVATION
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text
AutoCAD SHX Text
BUILDING 2 GROUND FLOOR ROOM 14 EXISTING
AutoCAD SHX Text
PL-115
AutoCAD SHX Text
KEYED NOTES:
AutoCAD SHX Text DEAD LEG CONTINUES ONTO GROUND FLOOR. SEE ASSOCIATED GROUND FLOOR PLAN FOR CONTINUATION AND DEAD LEG DESIGNATION.
AutoCAD SHX Text
AutoCAD SHX Text N
AutoCAD SHX Text
PROJECT NORTH
AutoCAD SHX Text
KEYED DEMOLITION NOTES:
AutoCAD SHX Text REMOVE NOTED WATER FOUNTAIN. EXISTING DOMESTIC COLD WATER SUPPLY PIPING AND SANITARY PIPING CONNECTIONS TO WATER FOUNTAIN SHALL BE MAINTAINED AND UTILIZED FOR CONNECTION TO NEW BOTTLE FILLER. SEE NEW WORK PLAN 1/PL-215 FOR INSTALLATION OF NEW BOTTLE FILLER.
AutoCAD SHX Text EXISTING DOMESTIC COLD WATER PIPING SERVING NOTED WATER FOUNTAIN IS ASBESTOS INSULATED. REFER TO DRAWING PL-030 FOR ACM REMOVALS. SEE SPECIFICATION SECTION 01 35 26 FOR PROPER REMOVAL AND DISPOSAL OF ASBESTOS INSULATION.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SMOKE RESISTANT BARRIER
AutoCAD SHX Text
30 MINUTE SMOKE BARRIER
AutoCAD SHX Text
1 HOUR FIRE/SMOKE BARRIER
AutoCAD SHX Text
2 HOUR FIRE/SMOKE BARRIER
AutoCAD SHX Text
1 HOUR FIRE BARRIER
AutoCAD SHX Text
2 HOUR FIRE BARRIER
AutoCAD SHX Text
3 HOUR FIRE BARRIER
AutoCAD SHX Text
FIRE BARRIER LINETYPES
AutoCAD SHX Text
ENLARGED PLAN AND ELEVATION LOCATION SCHEDULE:
AutoCAD SHX Text
1/PL-115
AutoCAD SHX Text
SEE DRAWING 1/PL-113
AutoCAD SHX Text
2/PL-115
AutoCAD SHX Text
SEE DRAWING 1/PL-115
AutoCAD SHX Text
GENERAL NOTES:
AutoCAD SHX Text 1.
AutoCAD SHX Text PLUMBING DRAWINGS ARE BASED ON OBSERVED AS-BUILT CONDITIONS. NOT ALL PIPING IS ACCESSIBLE. IN CASE WORK IS TO BE COMPLETED WITHIN AN INACCESSIBLE AREA, CONTRACTOR SHALL VERIFY PIPE SIZE, LENGTH, ROUTING, END POINT, AND ORIGIN OF ANY PIPING THAT CONTINUES INTO AN INACCESSIBLE AREA PRIOR TO START OF WORK.
AutoCAD SHX Text 2.
AutoCAD SHX Text ALL DOMESTIC WATER SHALL BE RESTORED TO ORIGINAL CONDITION UPON COMPLETION OF WORKDAY. THIS INCLUDES ALL SHIFTS AND SHUTDOWNS REQUIRED. ALL SHUTDOWNS SHALL BE COORDINATED WITH COR PRIOR TO START OF WORK. CONTRACTOR SHALL PROVIDE SCHEDULE OF ALL SHUTDOWNS AND EXPECTED DOWN TIMES TO COR FOR REVIEW BEFORE INITIATING WORK.
AutoCAD SHX Text 3.
AutoCAD SHX Text CONTRACTOR SHALL REVIEW AND ENSURE ALL WORK IS COMPLETED IN ACCORDANCE WITH THE GENERAL FIRE RATED BARRIER NOTES ON PL-001.
NOTE: NO DEMO WORK SHALL BE COMPLETED WITHIN PLAN 2/PL-115.
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h 6/
/2
:3
9:
P M
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
IMPROVE POTABLE WATER
DISTRIBUTION SYSTEM
222 RICHMOND AVENUE
BATAVIA, NY 14020
528A4-16-205
Project Director
06/08/2022Revisions: Date:
PL-116
D.L.E.
VA NEW YORK
HEALTHCARE SYSTEM
CONSTRUCTION DOCUMENTS
34 BROWN STREET
HONESDALE, PA 18431
OFFICE : (570) 253-0846
FAX : (570) 253-1935
WWW.NEINFRA.COM
NORTHEAST INFRASTRUCTURE, LLC
BUILDING 2 FIRST FLOOR EXISITING
CONDITIONS/DEMOLITION PLUMBING
PLAN AND ENLARGED PLUMBING PLAN
F.R.O.
AutoCAD SHX Text
DISH WASHER
AutoCAD SHX Text
DISHROOM 108
AutoCAD SHX Text
SINK BASIN
AutoCAD SHX Text
WASTE RECYCLING UNIT
AutoCAD SHX Text
TO DISHWASHER
AutoCAD SHX Text
NI-24
AutoCAD SHX Text
NI-25
AutoCAD SHX Text
NI-26
AutoCAD SHX Text
NI-32
AutoCAD SHX Text
NI-33
AutoCAD SHX Text
NI-34
AutoCAD SHX Text
NI-27
AutoCAD SHX Text
NI-28
AutoCAD SHX Text
1" CW,HW
AutoCAD SHX Text
TO EQUIPMENT
AutoCAD SHX Text 2-1-108-001
AutoCAD SHX Text
1/2" CW,HW
AutoCAD SHX Text
1/2" CW
AutoCAD SHX Text
1/2 CW,HW
AutoCAD SHX Text
1/2" HW
AutoCAD SHX Text
1" HW
AutoCAD SHX Text
NI-29
AutoCAD SHX Text
NI-30
AutoCAD SHX Text
NI-31
AutoCAD SHX Text
TO DISHWASHER
AutoCAD SHX Text
ACM
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text G
AutoCAD SHX Text G
AutoCAD SHX Text H
AutoCAD SHX Text H
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text K
AutoCAD SHX Text K
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 106A
AutoCAD SHX Text 106B
AutoCAD SHX Text
AutoCAD SHX Text 106D
AutoCAD SHX Text 106F
AutoCAD SHX Text 106G
AutoCAD SHX Text 106C
AutoCAD SHX Text 106H
AutoCAD SHX Text 106E
AutoCAD SHX Text
AutoCAD SHX Text 103A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 103C
AutoCAD SHX Text 103B
AutoCAD SHX Text
AutoCAD SHX Text 111A
AutoCAD SHX Text
AutoCAD SHX Text 1000G
AutoCAD SHX Text 101A
AutoCAD SHX Text 101B
AutoCAD SHX Text 101C
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 107A
AutoCAD SHX Text 107B
AutoCAD SHX Text 107C
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DISHROOM 108
AutoCAD SHX Text 110A
AutoCAD SHX Text
1 1/4" HW
AutoCAD SHX Text
1/2" HW
AutoCAD SHX Text
1/2" CW
AutoCAD SHX Text
3/4" CW,HW
AutoCAD SHX Text
1" CW
AutoCAD SHX Text
1/2" CW,HW
AutoCAD SHX Text
3/4" CW,HW
AutoCAD SHX Text
1/2" CW,HW
AutoCAD SHX Text
1/2" CW,HW
AutoCAD SHX Text
3/4" CW,HW
AutoCAD SHX Text
COFFEE MACHINE
AutoCAD SHX Text
STEAM KETTLE
AutoCAD SHX Text
ICE MACHINE
AutoCAD SHX Text 2-1-107-005-A
AutoCAD SHX Text 2-1-107-006-A
AutoCAD SHX Text 2-1-107-007-A
AutoCAD SHX Text
NI-22
AutoCAD SHX Text
NI-23
AutoCAD SHX Text
2" CW 1 1/4" HW 1/2" HWR
AutoCAD SHX Text
3/8" CW FLEX
AutoCAD SHX Text 2-1-108-002
AutoCAD SHX Text
1/2" HW
AutoCAD SHX Text
AutoCAD SHX Text
ACM
AutoCAD SHX Text 2-1-107-004-A
AutoCAD SHX Text 2-1-107-003-A
AutoCAD SHX Text
PLUMBING LINE TYPES
AutoCAD SHX Text
COLD WATER
AutoCAD SHX Text
HOT WATER
AutoCAD SHX Text
HOT WATER RETURN
AutoCAD SHX Text
PLUMBING FIELD STUDY KEY SYMBOLS
AutoCAD SHX Text TYPE A - PIPE LENGTH GREATER THAN TWICE THE DIAMETER OF THE PIPE SIZE TERMINATING AT CAP, VALVE, OR FITTING.
AutoCAD SHX Text TYPE B - PIPE LENGTH GREATER THAN TWICE THE DIAMETER OF THE PIPES TERMINATING AT AN INFREQUENTLY USED PLUMBING FIXTURE.
AutoCAD SHX Text TYPE C - PIPE LENGTH GREATER THAN 25 FEET TERMINATING AT A FREQUENTLY USED PLUMBING FIXTURE
AutoCAD SHX Text
DEAD LEG TAG
AutoCAD SHX Text
BACK FLOW PREVENTER TAG
AutoCAD SHX Text
CROSS-CONNECTION TAG
AutoCAD SHX Text
REMEDIATE DEAD LEG
AutoCAD SHX Text
NON-INSULATED PIPE REFER TO SCHEDULE
AutoCAD SHX Text
XXX-XX-XXX-XXX
AutoCAD SHX Text
XXX-XX-XXX-XXX
AutoCAD SHX Text
XXX-XXX
AutoCAD SHX Text
XX-XX
AutoCAD SHX Text
NI-X
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
CONDITIONS/DEMOLITION PLUMBING PLAN
AutoCAD SHX Text 1/8"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
BUILDING 2 FIRST FLOOR EXISTING
AutoCAD SHX Text
PL-116
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
CONDITIONS/DEMOLITION ENLARGED PLUMBING PLAN
AutoCAD SHX Text 1/2"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
BUILDING 2 FIRST FLOOR ROOM 108 EXISTING
AutoCAD SHX Text
PL-116
AutoCAD SHX Text N
AutoCAD SHX Text
PROJECT NORTH
AutoCAD SHX Text N
AutoCAD SHX Text
PROJECT NORTH
AutoCAD SHX Text
ENLARGED PLAN PLUMBING LINE TYPES
AutoCAD SHX Text
COLD WATER
AutoCAD SHX Text
HOT WATER
AutoCAD SHX Text
HOT WATER RETURN
AutoCAD SHX Text
SMOKE RESISTANT BARRIER
AutoCAD SHX Text
30 MINUTE SMOKE BARRIER
AutoCAD SHX Text
1 HOUR FIRE/SMOKE BARRIER
AutoCAD SHX Text
2 HOUR FIRE/SMOKE BARRIER
AutoCAD SHX Text
1 HOUR FIRE BARRIER
AutoCAD SHX Text
2 HOUR FIRE BARRIER
AutoCAD SHX Text
3 HOUR FIRE BARRIER
AutoCAD SHX Text
FIRE BARRIER LINETYPES
AutoCAD SHX Text
ENLARGED PLAN LOCATION SCHEDULE:
AutoCAD SHX Text
2/PL-116
AutoCAD SHX Text
SEE DRAWING 1/PL-116
AutoCAD SHX Text
GENERAL NOTES:
AutoCAD SHX Text 1.
AutoCAD SHX Text PLUMBING DRAWINGS ARE BASED ON OBSERVED AS-BUILT CONDITIONS. NOT ALL PIPING IS ACCESSIBLE. IN CASE WORK IS TO BE COMPLETED WITHIN AN INACCESSIBLE AREA, CONTRACTOR SHALL VERIFY PIPE SIZE, LENGTH, ROUTING, END POINT, AND ORIGIN OF ANY PIPING THAT CONTINUES INTO AN INACCESSIBLE AREA PRIOR TO START OF WORK.
AutoCAD SHX Text 2.
AutoCAD SHX Text ALL DOMESTIC WATER SHALL BE RESTORED TO ORIGINAL CONDITION UPON COMPLETION OF WORKDAY. THIS INCLUDES ALL SHIFTS AND SHUTDOWNS REQUIRED. ALL SHUTDOWNS SHALL BE COORDINATED WITH COR PRIOR TO START OF WORK. CONTRACTOR SHALL PROVIDE SCHEDULE OF ALL SHUTDOWNS AND EXPECTED DOWN TIMES TO COR FOR REVIEW BEFORE INITIATING WORK.
AutoCAD SHX Text 3.
AutoCAD SHX Text CONTRACTOR SHALL REVIEW AND ENSURE ALL WORK IS COMPLETED IN ACCORDANCE WITH THE GENERAL FIRE RATED BARRIER NOTES ON PL-001.
AutoCAD SHX Text
KEYED DEMOLITION NOTES:
AutoCAD SHX Text REMOVE NOTED WATER FOUNTAIN. EXISTING DOMESTIC COLD WATER SUPPLY PIPING AND SANITARY PIPING CONNECTIONS TO WATER FOUNTAIN SHALL BE MAINTAINED AND UTILIZED FOR CONNECTION TO NEW BOTTLE FILLER. SEE NEW WORK PLAN 1/PL-216 FOR INSTALLATION OF NEW BOTTLE FILLER.
AutoCAD SHX Text EXISTING DOMESTIC COLD WATER PIPING SERVING NOTED WATER FOUNTAIN IS ASBESTOS INSULATED. REFER TO DRAWING PL-030 FOR ACM REMOVALS. SEE SPECIFICATION SECTION 01 35 26 FOR PROPER REMOVAL AND DISPOSAL OF ASBESTOS INSULATION.
AutoCAD SHX Text CONTRACTOR SHALL RELOCATE ANY EXISTING EQUIPMENT ON NOTED WALL AS REQUIRED FOR INSTALLATION OF NEW SINK. CONTRACTOR SHALL COORDINATE RELOCATION OF EQUIPMENT WITH VA COR. CONTRACTOR SHALL REMEDIATE ALL ASBESTOS WITHIN WORK AREA PRIOR TO START OF WORK. SEE NEW WORK DRAWING 2/PL-216 FOR LOCATION OF NEW SINK AND PL-030 FOR ASSOCIATED ASBESTOS REMOVAL.
AutoCAD SHX Text
AutoCAD SHX Text
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h 6/
/2
:3
9:
P M
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
IMPROVE POTABLE WATER
DISTRIBUTION SYSTEM
222 RICHMOND AVENUE
BATAVIA, NY 14020
528A4-16-205
Project Director
06/08/2022Revisions: Date:
PL-117
D.L.E.
VA NEW YORK
HEALTHCARE SYSTEM
CONSTRUCTION DOCUMENTS
34 BROWN STREET
HONESDALE, PA 18431
OFFICE : (570) 253-0846
FAX : (570) 253-1935
WWW.NEINFRA.COM
NORTHEAST INFRASTRUCTURE, LLC
BUILDING 2 SECOND FLOOR
EXISTING CONDITIONS/DEMOLITION
PLUMBING PLAN
F.R.O.
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text G
AutoCAD SHX Text G
AutoCAD SHX Text H
AutoCAD SHX Text H
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text K
AutoCAD SHX Text K
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
2" CW 1 1/4" HW 1/2" HWR
AutoCAD SHX Text
1 1/4" CW(TYP)
AutoCAD SHX Text
1/2" CW,HW(TYP)
AutoCAD SHX Text
1 1/4" CW(TYP)
AutoCAD SHX Text
1/2" CW,HW(TYP)
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 204E
AutoCAD SHX Text 204F
AutoCAD SHX Text 204G
AutoCAD SHX Text 204C
AutoCAD SHX Text
AutoCAD SHX Text 204D
AutoCAD SHX Text 204B
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 207A
AutoCAD SHX Text
ACM
AutoCAD SHX Text
PLUMBING LINE TYPES
AutoCAD SHX Text
COLD WATER
AutoCAD SHX Text
HOT WATER
AutoCAD SHX Text
HOT WATER RETURN
AutoCAD SHX Text
PLUMBING FIELD STUDY KEY SYMBOLS
AutoCAD SHX Text TYPE A - PIPE LENGTH GREATER THAN TWICE THE DIAMETER OF THE PIPE SIZE TERMINATING AT CAP, VALVE, OR FITTING.
AutoCAD SHX Text TYPE B - PIPE LENGTH GREATER THAN TWICE THE DIAMETER OF THE PIPES TERMINATING AT AN INFREQUENTLY USED PLUMBING FIXTURE.
AutoCAD SHX Text TYPE C - PIPE LENGTH GREATER THAN 25 FEET TERMINATING AT A FREQUENTLY USED PLUMBING FIXTURE
AutoCAD SHX Text
DEAD LEG TAG
AutoCAD SHX Text
BACK FLOW PREVENTER TAG
AutoCAD SHX Text
CROSS-CONNECTION TAG
AutoCAD SHX Text
REMEDIATE DEAD LEG
AutoCAD SHX Text
NON-INSULATED PIPE REFER TO SCHEDULE
AutoCAD SHX Text
XXX-XX-XXX-XXX
AutoCAD SHX Text
XXX-XX-XXX-XXX
AutoCAD SHX Text
XXX-XXX
AutoCAD SHX Text
XX-XX
AutoCAD SHX Text
NI-X
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
CONDITIONS/DEMOLITION PLUMBING PLAN
AutoCAD SHX Text 1/8"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
BUILDING 2 SECOND FLOOR EXISTING
AutoCAD SHX Text
PL-117
AutoCAD SHX Text N
AutoCAD SHX Text
PROJECT NORTH
AutoCAD SHX Text
KEYED DEMOLITION NOTES:
AutoCAD SHX Text REMOVE NOTED WATER FOUNTAIN. EXISTING DOMESTIC COLD WATER SUPPLY PIPING AND SANITARY PIPING CONNECTIONS TO WATER FOUNTAIN SHALL BE MAINTAINED AND UTILIZED FOR CONNECTION TO NEW BOTTLE FILLER. SEE NEW WORK PLAN 1/PL-217 FOR INSTALLATION OF NEW BOTTLE FILLER.
AutoCAD SHX Text EXISTING DOMESTIC COLD WATER PIPING SERVING NOTED WATER FOUNTAIN IS ASBESTOS INSULATED. REFER TO DRAWING PL-030 FOR ACM REMOVALS. SEE SPECIFICATION SECTION 01 35 26 FOR PROPER REMOVAL AND DISPOSAL OF ASBESTOS INSULATION.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SMOKE RESISTANT BARRIER
AutoCAD SHX Text
30 MINUTE SMOKE BARRIER
AutoCAD SHX Text
1 HOUR FIRE/SMOKE BARRIER
AutoCAD SHX Text
2 HOUR FIRE/SMOKE BARRIER
AutoCAD SHX Text
1 HOUR FIRE BARRIER
AutoCAD SHX Text
2 HOUR FIRE BARRIER
AutoCAD SHX Text
3 HOUR FIRE BARRIER
AutoCAD SHX Text
FIRE BARRIER LINETYPES
AutoCAD SHX Text
GENERAL NOTES:
AutoCAD SHX Text 1.
AutoCAD SHX Text PLUMBING DRAWINGS ARE BASED ON OBSERVED AS-BUILT CONDITIONS. NOT ALL PIPING IS ACCESSIBLE. IN CASE WORK IS TO BE COMPLETED WITHIN AN INACCESSIBLE AREA, CONTRACTOR SHALL VERIFY PIPE SIZE, LENGTH, ROUTING, END POINT, AND ORIGIN OF ANY PIPING THAT CONTINUES INTO AN INACCESSIBLE AREA PRIOR TO START OF WORK.
AutoCAD SHX Text 2.
AutoCAD SHX Text ALL DOMESTIC WATER SHALL BE RESTORED TO ORIGINAL CONDITION UPON COMPLETION OF WORKDAY. THIS INCLUDES ALL SHIFTS AND SHUTDOWNS REQUIRED. ALL SHUTDOWNS SHALL BE COORDINATED WITH COR PRIOR TO START OF WORK. CONTRACTOR SHALL PROVIDE SCHEDULE OF ALL SHUTDOWNS AND EXPECTED DOWN TIMES TO COR FOR REVIEW BEFORE INITIATING WORK.
AutoCAD SHX Text 3.
CONTRACTOR SHALL REVIEW AND ENSURE ALL WORK IS COMPLETED IN ACCORDANCE WITH THE GENERAL FIRE RATED BARRIER NOTES ON PL-001.
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h 6/
/2
:3
9:
P M
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
IMPROVE POTABLE WATER
DISTRIBUTION SYSTEM
222 RICHMOND AVENUE
BATAVIA, NY 14020
528A4-16-205
Project Director
06/08/2022Revisions: Date:
PL-118
D.L.E.
VA NEW YORK
HEALTHCARE SYSTEM
CONSTRUCTION DOCUMENTS
34 BROWN STREET
HONESDALE, PA 18431
OFFICE : (570) 253-0846
FAX : (570) 253-1935
WWW.NEINFRA.COM
NORTHEAST INFRASTRUCTURE, LLC
T.W.D.
BUILDING 3 GROUND FLOOR EXISTING
CONDITIONS/DEMOLITION PLUMBING PLAN
AND ENLARGED PLUMBING PLANS 3
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text G
AutoCAD SHX Text G
AutoCAD SHX Text C
AutoCAD SHX Text
14 ELEVATOR CLOSET
AutoCAD SHX Text
13 MECH.
AutoCAD SHX Text
12 VESTIBULE
AutoCAD SHX Text
AutoCAD SHX Text
G01 OPEN OFFICES
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
HALLWAY
AutoCAD SHX Text
AutoCAD SHX Text
02 SUPERVISOR
AutoCAD SHX Text
TOILET G02B
AutoCAD SHX Text
BREAK RM
AutoCAD SHX Text
MECH.
AutoCAD SHX Text
AutoCAD SHX Text 3-G-04-001-A
AutoCAD SHX Text 3-G-01-002-A
AutoCAD SHX Text 3-G-01-001-A
AutoCAD SHX Text
AutoCAD SHX Text
1/2" CW,HW
AutoCAD SHX Text
1" CW
AutoCAD SHX Text
AutoCAD SHX Text
OUTSIDE-001
AutoCAD SHX Text 3-G
AutoCAD SHX Text
OUTSIDE-003
AutoCAD SHX Text 3-G
AutoCAD SHX Text
TO BUILDING ONE
AutoCAD SHX Text 3-G
AutoCAD SHX Text
OUTSIDE-002
AutoCAD SHX Text
1" CW 1/2" HW
AutoCAD SHX Text
3/4" HW 1/2" HWR
AutoCAD SHX Text
2" CW 3/4" HW 1/2" HWR
AutoCAD SHX Text
1/2" CW,HW
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ACM
AutoCAD SHX Text
1/2" CW,HW
AutoCAD SHX Text
2" CW MAIN
AutoCAD SHX Text
2" CW 3/4" HW 1/2" HWR
AutoCAD SHX Text 05-001
AutoCAD SHX Text 03-G
AutoCAD SHX Text
1/2" CW
AutoCAD SHX Text
1" CW
AutoCAD SHX Text 03-G-05-001
AutoCAD SHX Text
3/4" HW 1/2" HWR
AutoCAD SHX Text
AutoCAD SHX Text 3-G-05-001-A
AutoCAD SHX Text
WATER HEATER
AutoCAD SHX Text
WASHER
AutoCAD SHX Text
2" CW 3/4" HW 1/2" HWR
AutoCAD SHX Text
3/4" CW,HW 1/2" HWR
AutoCAD SHX Text
1" CW
AutoCAD SHX Text
1" CW 1/2" HW,HWR
AutoCAD SHX Text
1" CW(TYP)
AutoCAD SHX Text
1/2" CW,HW(TYP)
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ACM
AutoCAD SHX Text
PLUMBING LINE TYPES
AutoCAD SHX Text
COLD WATER
AutoCAD SHX Text
HOT WATER
AutoCAD SHX Text
HOT WATER RETURN
AutoCAD SHX Text
PLUMBING FIELD STUDY KEY SYMBOLS
AutoCAD SHX Text TYPE A - PIPE LENGTH GREATER THAN TWICE THE DIAMETER OF THE PIPE SIZE TERMINATING AT CAP, VALVE, OR FITTING.
AutoCAD SHX Text TYPE B - PIPE LENGTH GREATER THAN TWICE THE DIAMETER OF THE PIPES TERMINATING AT AN INFREQUENTLY USED PLUMBING FIXTURE.
AutoCAD SHX Text TYPE C - PIPE LENGTH GREATER THAN 25 FEET TERMINATING AT A FREQUENTLY USED PLUMBING FIXTURE
AutoCAD SHX Text
DEAD LEG TAG
AutoCAD SHX Text
BACK FLOW PREVENTER TAG
AutoCAD SHX Text
CROSS-CONNECTION TAG
AutoCAD SHX Text
REMEDIATE DEAD LEG
AutoCAD SHX Text
NON-INSULATED PIPE REFER TO SCHEDULE
AutoCAD SHX Text
XXX-XX-XXX-XXX
AutoCAD SHX Text
XXX-XX-XXX-XXX
AutoCAD SHX Text
XXX-XXX
AutoCAD SHX Text
XX-XX
AutoCAD SHX Text
NI-X
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
CONDITIONS/DEMOLITION PLUMBING PLAN
AutoCAD SHX Text 1/8"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
BUILDING 3 GROUND FLOOR EXISTING
AutoCAD SHX Text
PL-118
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
ENLARGED PLUMBING PLAN
AutoCAD SHX Text 1/4"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
05 EXISTING CONDITIONS/DEMOLITION
AutoCAD SHX Text
PL-118
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
CONDITIONS/DEMOLITION ENLARGED PLUMBING PLAN
AutoCAD SHX Text 1/4"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
BUILDING 3 GROUND FLOOR ROOM 09 EXISTING
AutoCAD SHX Text
PL-118
AutoCAD SHX Text
ENLARGED PLAN PLUMBING LINE TYPES
AutoCAD SHX Text
COLD WATER
AutoCAD SHX Text
HOT WATER
AutoCAD SHX Text
HOT WATER RETURN
AutoCAD SHX Text N
AutoCAD SHX Text
PROJECT NORTH
AutoCAD SHX Text N
AutoCAD SHX Text
PROJECT NORTH
AutoCAD SHX Text N
AutoCAD SHX Text
PROJECT NORTH
AutoCAD SHX Text
KEYED DEMOLITION NOTES:
AutoCAD SHX Text REMOVE NOTED WATER FOUNTAIN. EXISTING DOMESTIC COLD WATER SUPPLY PIPING AND SANITARY PIPING CONNECTIONS TO WATER FOUNTAIN SHALL BE MAINTAINED AND UTILIZED FOR CONNECTION TO NEW BOTTLE FILLER. SEE NEW WORK PLAN 3/PL-218 FOR INSTALLATION OF NEW BOTTLE FILLER.
AutoCAD SHX Text EXISTING DOMESTIC COLD WATER PIPING SERVING NOTED WATER FOUNTAIN IS ASBESTOS INSULATED. REFER TO DRAWING PL-030 FOR ACM REMOVALS. SEE SPECIFICATION SECTION 01 35 26 FOR PROPER REMOVAL AND DISPOSAL OF ASBESTOS INSULATION.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SMOKE RESISTANT BARRIER
AutoCAD SHX Text
30 MINUTE SMOKE BARRIER
AutoCAD SHX Text
1 HOUR FIRE/SMOKE BARRIER
AutoCAD SHX Text
2 HOUR FIRE/SMOKE BARRIER
AutoCAD SHX Text
1 HOUR FIRE BARRIER
AutoCAD SHX Text
2 HOUR FIRE BARRIER
AutoCAD SHX Text
3 HOUR FIRE BARRIER
AutoCAD SHX Text
FIRE BARRIER LINETYPES
AutoCAD SHX Text
BUILDING 3 GROUND FLOOR ROOM
AutoCAD SHX Text
GENERAL NOTES:
AutoCAD SHX Text 1.
AutoCAD SHX Text PLUMBING DRAWINGS ARE BASED ON OBSERVED AS-BUILT CONDITIONS. NOT ALL PIPING IS ACCESSIBLE. IN CASE WORK IS TO BE COMPLETED WITHIN AN INACCESSIBLE AREA, CONTRACTOR SHALL VERIFY PIPE SIZE, LENGTH, ROUTING, END POINT, AND ORIGIN OF ANY PIPING THAT CONTINUES INTO AN INACCESSIBLE AREA PRIOR TO START OF WORK.
AutoCAD SHX Text 2.
AutoCAD SHX Text ALL DOMESTIC WATER SHALL BE RESTORED TO ORIGINAL CONDITION UPON COMPLETION OF WORKDAY. THIS INCLUDES ALL SHIFTS AND SHUTDOWNS REQUIRED. ALL SHUTDOWNS SHALL BE COORDINATED WITH COR PRIOR TO START OF WORK. CONTRACTOR SHALL PROVIDE SCHEDULE OF ALL SHUTDOWNS AND EXPECTED DOWN TIMES TO COR FOR REVIEW BEFORE INITIATING WORK.
AutoCAD SHX Text 3.
AutoCAD SHX Text CONTRACTOR SHALL REVIEW AND ENSURE ALL WORK IS COMPLETED IN ACCORDANCE WITH THE GENERAL FIRE RATED BARRIER NOTES ON PL-001.
AutoCAD SHX Text
ENLARGED PLAN LOCATION SCHEDULE:
AutoCAD SHX Text
2/PL-118
AutoCAD SHX Text
SEE DRAWING 1/PL-118
AutoCAD SHX Text
3/PL-118
SEE DRAWING 1/PL-118
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h 6/
/2
:3
9:
P M
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
IMPROVE POTABLE WATER
DISTRIBUTION SYSTEM
222 RICHMOND AVENUE
BATAVIA, NY 14020
528A4-16-205
Project Director
06/08/2022Revisions: Date:
PL-119
D.L.E.
VA NEW YORK
HEALTHCARE SYSTEM
CONSTRUCTION DOCUMENTS
34 BROWN STREET
HONESDALE, PA 18431
OFFICE : (570) 253-0846
FAX : (570) 253-1935
WWW.NEINFRA.COM
NORTHEAST INFRASTRUCTURE, LLC
T.W.D.
BUILDING 3 FIRST AND SECOND FLOOR
EXISTING CONDITIONS/DEMOLITION
PLUMBING PLANS 3
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text G
AutoCAD SHX Text G
AutoCAD SHX Text
AutoCAD SHX Text 203A
AutoCAD SHX Text
AutoCAD SHX Text 206A
AutoCAD SHX Text
VEST.
AutoCAD SHX Text
ELEV.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 203B
AutoCAD SHX Text 203C
AutoCAD SHX Text 203D
AutoCAD SHX Text
1" CW(TYP)
AutoCAD SHX Text
1/2" CW
AutoCAD SHX Text
3/4" CW,HW
AutoCAD SHX Text 03-02-205-001
AutoCAD SHX Text
1 1/2" CW 3/4" HW
AutoCAD SHX Text
1/2" CW,HW (TYP)
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ACM
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text G
AutoCAD SHX Text G
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text
ELEV.
AutoCAD SHX Text
VEST.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 103A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 110A
AutoCAD SHX Text
AutoCAD SHX Text 110B
AutoCAD SHX Text 110C
AutoCAD SHX Text
1/2" CW,HW (TYP)
AutoCAD SHX Text
1/2" CW,HW
AutoCAD SHX Text
1" CW
AutoCAD SHX Text 03-01-109-001
AutoCAD SHX Text
1 1/2" CW 3/4" HW
AutoCAD SHX Text
1" CW
AutoCAD SHX Text
1/2" CW
AutoCAD SHX Text
3/4" CW,HW
AutoCAD SHX Text
1" CW(TYP)
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 102B
AutoCAD SHX Text
ACM
AutoCAD SHX Text
PLUMBING LINE TYPES
AutoCAD SHX Text
COLD WATER
AutoCAD SHX Text
HOT WATER
AutoCAD SHX Text
HOT WATER RETURN
AutoCAD SHX Text
PLUMBING FIELD STUDY KEY SYMBOLS
AutoCAD SHX Text TYPE A - PIPE LENGTH GREATER THAN TWICE THE DIAMETER OF THE PIPE SIZE TERMINATING AT CAP, VALVE, OR FITTING.
AutoCAD SHX Text TYPE B - PIPE LENGTH GREATER THAN TWICE THE DIAMETER OF THE PIPES TERMINATING AT AN INFREQUENTLY USED PLUMBING FIXTURE.
AutoCAD SHX Text TYPE C - PIPE LENGTH GREATER THAN 25 FEET TERMINATING AT A FREQUENTLY USED PLUMBING FIXTURE
AutoCAD SHX Text
DEAD LEG TAG
AutoCAD SHX Text
BACK FLOW PREVENTER TAG
AutoCAD SHX Text
CROSS-CONNECTION TAG
AutoCAD SHX Text
REMEDIATE DEAD LEG
AutoCAD SHX Text
NON-INSULATED PIPE REFER TO SCHEDULE
AutoCAD SHX Text
XXX-XX-XXX-XXX
AutoCAD SHX Text
XXX-XX-XXX-XXX
AutoCAD SHX Text
XXX-XXX
AutoCAD SHX Text
XX-XX
AutoCAD SHX Text
NI-X
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
CONDITIONS/DEMOLITION PLUMBING PLAN
AutoCAD SHX Text 1/8"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
BUILDING 3 FIRST FLOOR EXISTING
AutoCAD SHX Text
PL-119
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
CONDITIONS/DEMOLITION PLUMBING PLAN
AutoCAD SHX Text 1/8"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
BUILDING 3 SECOND FLOOR EXISTING
AutoCAD SHX Text
PL-119
AutoCAD SHX Text N
AutoCAD SHX Text
PROJECT NORTH
AutoCAD SHX Text N
AutoCAD SHX Text
PROJECT NORTH
AutoCAD SHX Text
KEYED DEMOLITION NOTES:
AutoCAD SHX Text REMOVE NOTED WATER FOUNTAIN. EXISTING DOMESTIC COLD WATER SUPPLY PIPING AND SANITARY PIPING CONNECTIONS TO WATER FOUNTAIN SHALL BE MAINTAINED AND UTILIZED FOR CONNECTION TO NEW BOTTLE FILLER. SEE NEW WORK PLAN 1/PL-219 FOR INSTALLATION OF NEW BOTTLE FILLER.
AutoCAD SHX Text REMOVE NOTED WATER FOUNTAIN. EXISTING DOMESTIC COLD WATER SUPPLY PIPING AND SANITARY PIPING CONNECTIONS TO WATER FOUNTAIN SHALL BE MAINTAINED AND UTILIZED FOR CONNECTION TO NEW BOTTLE FILLER. SEE NEW WORK PLAN 2/PL-219 FOR INSTALLATION OF NEW BOTTLE FILLER.
AutoCAD SHX Text EXISTING DOMESTIC COLD WATER PIPING SERVING NOTED WATER FOUNTAIN IS ASBESTOS INSULATED. REFER TO DRAWING PL-030 FOR ACM REMOVALS. SEE SPECIFICATION SECTION 01 35 26 FOR PROPER REMOVAL AND DISPOSAL OF ASBESTOS INSULATION.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SMOKE RESISTANT BARRIER
AutoCAD SHX Text
30 MINUTE SMOKE BARRIER
AutoCAD SHX Text
1 HOUR FIRE/SMOKE BARRIER
AutoCAD SHX Text
2 HOUR FIRE/SMOKE BARRIER
AutoCAD SHX Text
1 HOUR FIRE BARRIER
AutoCAD SHX Text
2 HOUR FIRE BARRIER
AutoCAD SHX Text
3 HOUR FIRE BARRIER
AutoCAD SHX Text
FIRE BARRIER LINETYPES
AutoCAD SHX Text
GENERAL NOTES:
AutoCAD SHX Text 1.
AutoCAD SHX Text PLUMBING DRAWINGS ARE BASED ON OBSERVED AS-BUILT CONDITIONS. NOT ALL PIPING IS ACCESSIBLE. IN CASE WORK IS TO BE COMPLETED WITHIN AN INACCESSIBLE AREA, CONTRACTOR SHALL VERIFY PIPE SIZE, LENGTH, ROUTING, END POINT, AND ORIGIN OF ANY PIPING THAT CONTINUES INTO AN INACCESSIBLE AREA PRIOR TO START OF WORK.
AutoCAD SHX Text 2.
AutoCAD SHX Text ALL DOMESTIC WATER SHALL BE RESTORED TO ORIGINAL CONDITION UPON COMPLETION OF WORKDAY. THIS INCLUDES ALL SHIFTS AND SHUTDOWNS REQUIRED. ALL SHUTDOWNS SHALL BE COORDINATED WITH COR PRIOR TO START OF WORK. CONTRACTOR SHALL PROVIDE SCHEDULE OF ALL SHUTDOWNS AND EXPECTED DOWN TIMES TO COR FOR REVIEW BEFORE INITIATING WORK.
AutoCAD SHX Text 3.
CONTRACTOR SHALL REVIEW AND ENSURE ALL WORK IS COMPLETED IN ACCORDANCE WITH THE GENERAL FIRE RATED BARRIER NOTES ON PL-001.
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h 6/
/2
:3
9:
P M
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
IMPROVE POTABLE WATER
DISTRIBUTION SYSTEM
222 RICHMOND AVENUE
BATAVIA, NY 14020
528A4-16-205
Project Director
06/08/2022Revisions: Date:
PL-120
D.L.E.
VA NEW YORK
HEALTHCARE SYSTEM
CONSTRUCTION DOCUMENTS
34 BROWN STREET
HONESDALE, PA 18431
OFFICE : (570) 253-0846
FAX : (570) 253-1935
WWW.NEINFRA.COM
NORTHEAST INFRASTRUCTURE, LLC
T.W.D.
BUILDING 4 BASEMENT/CRAWLSPACE AND
GROUND FLOOR EXISTING CONDITIONS/
DEMOLITION PLUMBING AND ENLARGED PLANS 4
AutoCAD SHX Text
1" CW
AutoCAD SHX Text
2 1/2" CW MAIN
AutoCAD SHX Text 4-B-G15-003-A
AutoCAD SHX Text 4-B-G15-001-A
AutoCAD SHX Text 4-B-G15-002-A
AutoCAD SHX Text
1 1/2" CW 3/4" HW,HWR
AutoCAD SHX Text
1 1/4" HW 3/4" HWR
AutoCAD SHX Text
STEAM WATER HEATER
AutoCAD SHX Text G15-001
AutoCAD SHX Text 4-G
AutoCAD SHX Text
NI-1
AutoCAD SHX Text
NI-4
AutoCAD SHX Text
1" CW
AutoCAD SHX Text
RISE TO THE TANK
AutoCAD SHX Text G15
AutoCAD SHX Text
2" CW
AutoCAD SHX Text
3/4" CW,HW
AutoCAD SHX Text
2" F.P. CW
AutoCAD SHX Text
NI-3
AutoCAD SHX Text
WATER HEATER
AutoCAD SHX Text
NI-2
AutoCAD SHX Text 04-B-G15-001
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text
3/4" CW,HW
AutoCAD SHX Text
1 1/4" CW 3/4" HW 1/2" HWR
AutoCAD SHX Text
1 1/4" CW 3/4" HW
AutoCAD SHX Text
1 1/2" CW 3/4" HW 3/4" HWR
AutoCAD SHX Text
2" F.P. CW
AutoCAD SHX Text
1/2" HW
AutoCAD SHX Text
1/2" CW
AutoCAD SHX Text
2" CW TO FIRE PROTECTION
AutoCAD SHX Text
1 1/4" CW 3/4" HW 1/2" HWR
AutoCAD SHX Text
3/4" CW,HW
AutoCAD SHX Text
2" F.P. CW
AutoCAD SHX Text
1 1/2" F.P. CW
AutoCAD SHX Text
1/2" CW
AutoCAD SHX Text
1 1/4" CW 3/4" HW 1/2" HWR
AutoCAD SHX Text
4-B-CS-001-A
AutoCAD SHX Text
4-B-CS-002-A
AutoCAD SHX Text
1/2" CW,HW
AutoCAD SHX Text
1" CW 1 1/4" HW 3/4" HWR
AutoCAD SHX Text
1 1/2" CW
AutoCAD SHX Text
AutoCAD SHX Text
PL-120
AutoCAD SHX Text
1/2" CW,HW
AutoCAD SHX Text
F.P. CW
AutoCAD SHX Text
OUTSIDE-002
AutoCAD SHX Text
4-CS
AutoCAD SHX Text
CRAWLSPACE
AutoCAD SHX Text G15
AutoCAD SHX Text
OUTSIDE-001
AutoCAD SHX Text
4-CS
AutoCAD SHX Text
OUTSIDE-003
AutoCAD SHX Text
4-CS
AutoCAD SHX Text
AutoCAD SHX Text
1" CW
AutoCAD SHX Text
1 1/2" F.P. CW
AutoCAD SHX Text
1 1/2" CW 3/4" HW,HWR
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text
1/2" CW,HW
AutoCAD SHX Text
1/2" CW,HW
AutoCAD SHX Text
3/4" CW,HW
AutoCAD SHX Text
WATER HEATER BELOW SINK
AutoCAD SHX Text
1/2" CW
AutoCAD SHX Text
1 1/4" CW
AutoCAD SHX Text
1/2" CW,HW(TYP)
AutoCAD SHX Text
1 1/2" CW 3/4" HW 1/2" HWR
AutoCAD SHX Text
1 1/4" CW 3/4" HW 1/2" HWR
AutoCAD SHX Text
1 1/4" CW 3/4" HW 1/2" HWR
AutoCAD SHX Text
1 1/4" CW 3/4" HW 1/2" HWR
AutoCAD SHX Text G01
AutoCAD SHX Text G14A
AutoCAD SHX Text
1/2" CW,HW
AutoCAD SHX Text G05
AutoCAD SHX Text G10
AutoCAD SHX Text G18
AutoCAD SHX Text G09
AutoCAD SHX Text G14
AutoCAD SHX Text G19
AutoCAD SHX Text G04
AutoCAD SHX Text G03
AutoCAD SHX Text G15
AutoCAD SHX Text G15A
AutoCAD SHX Text G13
AutoCAD SHX Text G14
AutoCAD SHX Text G06
AutoCAD SHX Text G07
AutoCAD SHX Text G08
AutoCAD SHX Text G11
AutoCAD SHX Text G12
AutoCAD SHX Text 04-G-013-001
AutoCAD SHX Text
1" CW
AutoCAD SHX Text
1 1/2" CW
AutoCAD SHX Text
1/2" CW,HW
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ACM
AutoCAD SHX Text 4-G-G10A-001-A
AutoCAD SHX Text
PLUMBING LINE TYPES
AutoCAD SHX Text
COLD WATER
AutoCAD SHX Text
HOT WATER
AutoCAD SHX Text
HOT WATER RETURN
AutoCAD SHX Text
PLUMBING FIELD STUDY KEY SYMBOLS
AutoCAD SHX Text TYPE A - PIPE LENGTH GREATER THAN TWICE THE DIAMETER OF THE PIPE SIZE TERMINATING AT CAP, VALVE, OR FITTING.
AutoCAD SHX Text TYPE B - PIPE LENGTH GREATER THAN TWICE THE DIAMETER OF THE PIPES TERMINATING AT AN INFREQUENTLY USED PLUMBING FIXTURE.
AutoCAD SHX Text TYPE C - PIPE LENGTH GREATER THAN 25 FEET TERMINATING AT A FREQUENTLY USED PLUMBING FIXTURE
AutoCAD SHX Text
DEAD LEG TAG
AutoCAD SHX Text
BACK FLOW PREVENTER TAG
AutoCAD SHX Text
CROSS-CONNECTION TAG
AutoCAD SHX Text
REMEDIATE DEAD LEG
AutoCAD SHX Text
NON-INSULATED PIPE REFER TO SCHEDULE
AutoCAD SHX Text
XXX-XX-XXX-XXX
AutoCAD SHX Text
XXX-XX-XXX-XXX
AutoCAD SHX Text
XXX-XXX
AutoCAD SHX Text
XX-XX
AutoCAD SHX Text
NI-X
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
CONDITIONS/DEMOLITION PLUMBING PLAN
AutoCAD SHX Text 1/8"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
BUILDING 4 BASEMENT/CRAWLSPACE EXISTING
AutoCAD SHX Text
PL-120
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
CONDITIONS/DEMOLITION ENLARGED PLUMBING PLAN
AutoCAD SHX Text 1/4"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
BUILDING 4 BASEMENT ROOM G15 EXISTING
AutoCAD SHX Text
PL-120
AutoCAD SHX Text N
AutoCAD SHX Text
PROJECT NORTH
AutoCAD SHX Text N
AutoCAD SHX Text
PROJECT NORTH
AutoCAD SHX Text
KEYED NOTES:
AutoCAD SHX Text DEAD LEG CONTINUES ONTO FIRST FLOOR PLAN. SEE ASSOCIATED FIRST FLOOR PLAN FOR CONTINUATION AND DEAD LEG DESIGNATION.
AutoCAD SHX Text
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
CONDITIONS/DEMOLITION PLUMBING PLAN
AutoCAD SHX Text 1/8"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
BUILDING 4 GROUND FLOOR EXISTING
AutoCAD SHX Text
PL-120
AutoCAD SHX Text N
AutoCAD SHX Text
PROJECT NORTH
AutoCAD SHX Text
ENLARGED PLAN PLUMBING LINE TYPES
AutoCAD SHX Text
COLD WATER
AutoCAD SHX Text
HOT WATER
AutoCAD SHX Text
HOT WATER RETURN
AutoCAD SHX Text
KEYED DEMOLITION NOTES:
AutoCAD SHX Text REMOVE NOTED WATER FOUNTAIN. EXISTING DOMESTIC COLD WATER SUPPLY PIPING AND SANITARY PIPING CONNECTIONS TO WATER FOUNTAIN SHALL BE MAINTAINED AND UTILIZED FOR CONNECTION TO NEW BOTTLE FILLER. SEE NEW WORK PLAN 2/PL-220 FOR INSTALLATION OF NEW BOTTLE FILLER.
AutoCAD SHX Text EXISTING DOMESTIC COLD WATER PIPING SERVING NOTED WATER FOUNTAIN IS ASBESTOS INSULATED. REFER TO DRAWING PL-030 FOR ACM REMOVALS. SEE SPECIFICATION SECTION 01 35 26 FOR PROPER REMOVAL AND DISPOSAL OF ASBESTOS INSULATION.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SMOKE RESISTANT BARRIER
AutoCAD SHX Text
30 MINUTE SMOKE BARRIER
AutoCAD SHX Text
1 HOUR FIRE/SMOKE BARRIER
AutoCAD SHX Text
2 HOUR FIRE/SMOKE BARRIER
AutoCAD SHX Text
1 HOUR FIRE BARRIER
AutoCAD SHX Text
2 HOUR FIRE BARRIER
AutoCAD SHX Text
3 HOUR FIRE BARRIER
AutoCAD SHX Text
FIRE BARRIER LINETYPES
AutoCAD SHX Text
GENERAL NOTES:
AutoCAD SHX Text 1.
AutoCAD SHX Text PLUMBING DRAWINGS ARE BASED ON OBSERVED AS-BUILT CONDITIONS. NOT ALL PIPING IS ACCESSIBLE. IN CASE WORK IS TO BE COMPLETED WITHIN AN INACCESSIBLE AREA, CONTRACTOR SHALL VERIFY PIPE SIZE, LENGTH, ROUTING, END POINT, AND ORIGIN OF ANY PIPING THAT CONTINUES INTO AN INACCESSIBLE AREA PRIOR TO START OF WORK.
AutoCAD SHX Text 2.
AutoCAD SHX Text ALL DOMESTIC WATER SHALL BE RESTORED TO ORIGINAL CONDITION UPON COMPLETION OF WORKDAY. THIS INCLUDES ALL SHIFTS AND SHUTDOWNS REQUIRED. ALL SHUTDOWNS SHALL BE COORDINATED WITH COR PRIOR TO START OF WORK. CONTRACTOR SHALL PROVIDE SCHEDULE OF ALL SHUTDOWNS AND EXPECTED DOWN TIMES TO COR FOR REVIEW BEFORE INITIATING WORK.
AutoCAD SHX Text 3.
AutoCAD SHX Text CONTRACTOR SHALL REVIEW AND ENSURE ALL WORK IS COMPLETED IN ACCORDANCE WITH THE GENERAL FIRE RATED BARRIER NOTES ON PL-001.
AutoCAD SHX Text
ENLARGED PLAN LOCATION SCHEDULE:
AutoCAD SHX Text
3/PL-120
SEE DRAWING 1/PL-120
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h 6/
/2
:3
9:
P M
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
IMPROVE POTABLE WATER
DISTRIBUTION SYSTEM
222 RICHMOND AVENUE
BATAVIA, NY 14020
528A4-16-205
Project Director
06/08/2022Revisions: Date:
PL-121
D.L.E.
VA NEW YORK
HEALTHCARE SYSTEM
CONSTRUCTION DOCUMENTS
34 BROWN STREET
HONESDALE, PA 18431
OFFICE : (570) 253-0846
FAX : (570) 253-1935
WWW.NEINFRA.COM
NORTHEAST INFRASTRUCTURE, LLC
T.W.D.
BUILDING 4 FIRST AND SECOND FLOOR
EXISTING CONDITIONS/DEMOLITION
PLUMBING PLANS 4
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 202A
AutoCAD SHX Text
AutoCAD SHX Text 201A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 203A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
1/2" CW,HW
AutoCAD SHX Text
1 1/4" CW
AutoCAD SHX Text
1/2" CW,HW
AutoCAD SHX Text
1 1/4" CW
AutoCAD SHX Text
1 1/4" CW 3/4" HW 1/2" HWR
AutoCAD SHX Text
1 1/4" CW 3/4" HW 1/2" HWR
AutoCAD SHX Text
1/2" CW,HW
AutoCAD SHX Text
1 1/4" CW
AutoCAD SHX Text
1 1/4" CW 3/4" HW 1/2" HWR
AutoCAD SHX Text
1/2" CW,HW
AutoCAD SHX Text
1/2" CW,HW
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1000E
AutoCAD SHX Text 103A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
1/2" CW,HW
AutoCAD SHX Text
1/2" CW,HW
AutoCAD SHX Text
1/2" CW
AutoCAD SHX Text
1 1/2" CW 3/4" HW 3/4" HWR
AutoCAD SHX Text
1 1/4" CW 3/4" HW 1/2" HWR
AutoCAD SHX Text
1 1/4" CW 3/4" HW 1/2" HWR
AutoCAD SHX Text
1/2" CW,HW
AutoCAD SHX Text 04-1
AutoCAD SHX Text 103B-001
AutoCAD SHX Text 103B
AutoCAD SHX Text
1 1/4" CW 3/4" HW 1/2" HWR
AutoCAD SHX Text
PLUMBING LINE TYPES
AutoCAD SHX Text
COLD WATER
AutoCAD SHX Text
HOT WATER
AutoCAD SHX Text
HOT WATER RETURN
AutoCAD SHX Text
PLUMBING FIELD STUDY KEY SYMBOLS
AutoCAD SHX Text TYPE A - PIPE LENGTH GREATER THAN TWICE THE DIAMETER OF THE PIPE SIZE TERMINATING AT CAP, VALVE, OR FITTING.
AutoCAD SHX Text TYPE B - PIPE LENGTH GREATER THAN TWICE THE DIAMETER OF THE PIPES TERMINATING AT AN INFREQUENTLY USED PLUMBING FIXTURE.
AutoCAD SHX Text TYPE C - PIPE LENGTH GREATER THAN 25 FEET TERMINATING AT A FREQUENTLY USED PLUMBING FIXTURE
AutoCAD SHX Text
DEAD LEG TAG
AutoCAD SHX Text
BACK FLOW PREVENTER TAG
AutoCAD SHX Text
CROSS-CONNECTION TAG
AutoCAD SHX Text
REMEDIATE DEAD LEG
AutoCAD SHX Text
NON-INSULATED PIPE REFER TO SCHEDULE
AutoCAD SHX Text
XXX-XX-XXX-XXX
AutoCAD SHX Text
XXX-XX-XXX-XXX
AutoCAD SHX Text
XXX-XXX
AutoCAD SHX Text
XX-XX
AutoCAD SHX Text
NI-X
AutoCAD SHX Text N
AutoCAD SHX Text
PROJECT NORTH
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
CONDITIONS/DEMOLITION PLUMBING PLAN
AutoCAD SHX Text 1/8"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
BUILDING 4 FIRST FLOOR EXISTING
AutoCAD SHX Text
PL-121
AutoCAD SHX Text N
AutoCAD SHX Text
PROJECT NORTH
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
CONDITIONS/DEMOLITION PLUMBING PLAN
AutoCAD SHX Text 1/8"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
BUILDING 4 SECOND FLOOR EXISTING
AutoCAD SHX Text
PL-121
AutoCAD SHX Text
SMOKE RESISTANT BARRIER
AutoCAD SHX Text
30 MINUTE SMOKE BARRIER
AutoCAD SHX Text
1 HOUR FIRE/SMOKE BARRIER
AutoCAD SHX Text
2 HOUR FIRE/SMOKE BARRIER
AutoCAD SHX Text
1 HOUR FIRE BARRIER
AutoCAD SHX Text
2 HOUR FIRE BARRIER
AutoCAD SHX Text
3 HOUR FIRE BARRIER
AutoCAD SHX Text
FIRE BARRIER LINETYPES
AutoCAD SHX Text
GENERAL NOTES:
AutoCAD SHX Text 1.
AutoCAD SHX Text PLUMBING DRAWINGS ARE BASED ON OBSERVED AS-BUILT CONDITIONS. NOT ALL PIPING IS ACCESSIBLE. IN CASE WORK IS TO BE COMPLETED WITHIN AN INACCESSIBLE AREA, CONTRACTOR SHALL VERIFY PIPE SIZE, LENGTH, ROUTING, END POINT, AND ORIGIN OF ANY PIPING THAT CONTINUES INTO AN INACCESSIBLE AREA PRIOR TO START OF WORK.
AutoCAD SHX Text 2.
AutoCAD SHX Text ALL DOMESTIC WATER SHALL BE RESTORED TO ORIGINAL CONDITION UPON COMPLETION OF WORKDAY. THIS INCLUDES ALL SHIFTS AND SHUTDOWNS REQUIRED. ALL SHUTDOWNS SHALL BE COORDINATED WITH COR PRIOR TO START OF WORK. CONTRACTOR SHALL PROVIDE SCHEDULE OF ALL SHUTDOWNS AND EXPECTED DOWN TIMES TO COR FOR REVIEW BEFORE INITIATING WORK.
AutoCAD SHX Text 3.
AutoCAD SHX Text CONTRACTOR SHALL REVIEW AND ENSURE ALL WORK IS COMPLETED IN ACCORDANCE WITH THE GENERAL FIRE RATED BARRIER NOTES ON PL-001.
AutoCAD SHX Text
NOTE: NO DEMO WORK SHALL BE COMPLETED WITHIN PLAN 2/PL-121.
NOTE: NO DEMO WORK SHALL BE COMPLETED WITHIN PLAN 1/PL-121.
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h 6/
/2
:3
9:
P M
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
IMPROVE POTABLE WATER
DISTRIBUTION SYSTEM
222 RICHMOND AVENUE
BATAVIA, NY 14020
528A4-16-205
Project Director
06/08/2022Revisions: Date:
PL-122
D.L.E.
VA NEW YORK
HEALTHCARE SYSTEM
CONSTRUCTION DOCUMENTS
34 BROWN STREET
HONESDALE, PA 18431
OFFICE : (570) 253-0846
FAX : (570) 253-1935
WWW.NEINFRA.COM
NORTHEAST INFRASTRUCTURE, LLC
T.W.D.
BUILDING 6 EXISTING CONDITIONS/
DEMOLITION PLUMBING PLANS
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text E
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
3/4" CW,HW
AutoCAD SHX Text
1 1/4" CW 3/4" HW 1/2" HWR
AutoCAD SHX Text
1/2" CW,HW
AutoCAD SHX Text
1/2" CW
AutoCAD SHX Text
1/2" CW,HW
AutoCAD SHX Text
REFRIGERATOR
AutoCAD SHX Text
1/2" CW,HW
AutoCAD SHX Text 6-1-109-001-A
AutoCAD SHX Text
DISHWASHER
AutoCAD SHX Text
RANGE
AutoCAD SHX Text
LIFT RAMP
AutoCAD SHX Text
AutoCAD SHX Text
HALL
AutoCAD SHX Text
AutoCAD SHX Text
FOYER
AutoCAD SHX Text
AutoCAD SHX Text
SIDE PORCH
AutoCAD SHX Text
AutoCAD SHX Text
BEDROOM
A…
This is the start of the file's text. The full file is on GovTribe.