site_description.pdf
PDF 13 KB Posted
- Attached to
- Operation of the Denison Job Corps Center
- Solicitation number
- DOLJ09RA00024
About this file
Attachment J-19 - Facility Survey Vol II
View the file
Other files
| File | Type | Posted |
|---|---|---|
| SF30 AMENDMENT No. 1 to RFP-Denison_00024.doc | DOC document | |
| Property List_J-13.pdf | ||
| deficiency_text.pdf | ||
| acm_inventory.pdf | ||
| Denison00024_RFP_FINAL_6-4-08.doc | DOC document | |
| Denison00024_MPO35 MSO20_J-20.pdf | ||
| Denison00024_CTT 10_J-20.pdf | ||
| energy_management.pdf | ||
| asset_management.pdf | ||
| Denison00024_inventory Estimate_J-23.doc | DOC document | |
| Denison00024_Workforce Investment Goals_J-7.pdf | ||
| Denison00024_Site Map_J-14.pdf | ||
| building_structures.pdf | ||
| PRH Regional Supplement 032007_w revised GAP_J-22.doc | DOC document | |
| Denison00024_Space Itilization Table_J-12.pdf | ||
| Denison00024_Itilities Fuel Usage_J-8.doc | DOC document | |
| Natl Compensation Model _Denison00024_J-17.xls | XLS spreadsheet | |
| o_and_m_deficiencies.pdf | ||
| building_descriptions.pdf | ||
| environmental_management.pdf | ||
| Denison00024_OMS 10_J-20.pdf | ||
| Denison Facility Survey Report_Vol I_J-19.pdf |
Show all 22
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Site Description Center: DENISON (00702)
Page: 1 Date: 04/22/2008
ACCESSIBILITY
Yes
The site has limited accessibility due to slopes.Comments:
NoNoNoNo
Nationally Registered Site
Site Eligible for National Register
Located in Historic District
Archaeological Significance
Drain System Soil Erosion Soil Erosion Location
No NoneUnderground
Comments:
Paving Type for Roads & Parking
There are concrete sidewalks with steps throughout the center.
Paving Type for Sidewalks
Asphalt Concrete
Comments:
Structures Fencing Outdoor Recreation
Five Storage Structures, Four Gazebos, Cook Out Shelter, Ball Field Booth
Chain Link, Wood Fence Field, Playground, Soft/Baseball
The concrete retaining walls are located at the west side of Recreation Building 21 and at the west side of Building
3. The sport field is enclosed by chain link fence.
ROADS, PARKING & SIDEWALKS
Water Source Water Authority Service Meter On-Site Treatment Plant
1. Water
Treatment Type Storage Type Storage Capacity Maintenance Responsibility
Center
NoMasterDenison Municipal UtilitiesPublic Water Authority
None 0None
Fire Hydrants On-Site Water Supply Storage Capacity Pressure Source # of Fire Pumps
Yes 0 0None Municipal
Sewage Treatment Sewer Line Owner
N/APublicly Owned Treatment Works CenterCenter
Maintenance ResponsibilityCapacity(Gallons)
Accessible Parking: Accessible Slope:
No
Curb Cuts:
No
Ramps:
NoNo
Site Accessible Route:
HISTORIC PRESERVATION
STORM WATER SYSTEM Number of Deficiencies = 2
Number of Deficiencies = 1SITE FEATURES
UTILITY
3. Sanitary Sewer System/ Sewage Treatment Plant
2. Fire Protection
Page: 2 Date: 04/22/2008
Natural
None
Comments:
Electric Company
PCB
Trans.
Transformer Mounting
Transformer Ownership
Systems Ownership
Maintenance Responsibility
Denison Municipal Utility Company
The majority of the primary distribution on center was upgraded by the utility company in 2003. Primary power dips underground where it enters the site from an overhead switch located west of Building 17 and Opportunity Drive.
Most distribution on the site is now distributed underground utilizing pad-mounted sectionalizing switches and pad-mounted transformers. There is an additional 13.2/7.6 kV underground feeder on center providing power to the gym as of the November 2005 Facility Survey. The utility is planning to convert the recently upgraded 4.16 kV distribution on center and change the incoming voltage to 13.2 kV, then to tie the two services together effectively loop feeding the center from two locations, all within the next ten years. Metering on center is a mix of primary and secondary, zoned and individual building meters. Storage buildings by the ball field, adjacent to HWY 30, are fed overhead from a pad-mounted transformer located where the property borders a small private college. Building 1 has the only 480/277V service on center. There is one center-owned generator, with both standby and life-safety automatic transfer switches, located at Building 1 and installed in 2004. The utility company owns and maintains most pole-mounted, photocell-controlled high intensity discharge security lights on center. The ball field has sports lighting for evening use.
Pole and Pad Utility, Center Utility, Center Utility, CenterNo
Comments:
Telephone Company On-site Line Owner
There is a site siren for site emergencies, located at Building 1. Fire alarm panels of Buildings 1, 2, 3, 10, 13, 17 and 21 are connected to a central annunciator panel located in Security Building 10. There are two T1 communication lines provided by Frontier, which enter at Building 4. Most buildings on center are connected by fiber utilizing VoIP for telephone and data. CCTV cameras are located throughout Dormitory Building 17 and are monitored in the RA offices for their respective zones. Security Building 10 also has CCTV cameras. Some buildings on center have cable TV and some have a satellite dish.
Frontier Telephone Company
Maint. Responsibility
Center Center
Security
CCTV Cameras, Black and White Monitors
06/01/1992
06/01/1992
Center
Center
Active
Active
Aboveground
Aboveground
Adjacent to Building
Adjacent to Building
Yes
Yes
Petroleum - Gasoline
Petroleum - Diesel Fuel
STORAGE TANK
TypeStatus Location Owner Fuel Type Capacity Install Date
4.16/2.3 kV, 3-Phase, 4 Wire
120/208V, 1&3-Phase and 120/240V, 1-PhaseOverhead & Underground
Overhead & UndergroundPrimary Service
Secondary Service
Distribution Characteristics
ID
Reg.
4. Gas
5. Central Plant
6. Electric
7. Communication
Purpose
Page: 3 Date: 04/22/2008
Earthquake Risk
Low Low LowMedium HighIBC Low
LightningEarthquake Def. Authority Flooding Tornado Hurricane Forest
Fire
Hail storms are common in this area.Comments:
GENERAL SITE CONDITION
Rating X Good Fair Poor
NATURAL HAZARDS
The facility condition is not impacting the functional use of the facility.
The facility condition IS impacting the functional use of the facility.