Facility_Planning_Report_(Vol._2).pdf

PDF 24 MB Posted

Attached to
Cascades Job Corps College and Career Academy
Solicitation number
DOL-ETA-16-R-00010
Issued by

About this file

Facility Planning Report (Vol. 2)

View the file

Other files

File Type Posted
Amendment_11.pdf PDF
Amendment_10.pdf PDF
Amendment_9.pdf PDF
Amendment_8.pdf PDF
Amendment_7.pdf PDF
Master_List_of_Standards_(Healthcare).rtf RTF text file
Top_10_Academic_Standards_by_Industry_(Healthcare_and_IT).doc DOC document
Career_Success_Standards.doc DOC document
IT_Academic_and_Applied_Academic_Standards.pdf PDF
Amendment_6.pdf PDF
Amendment_5.pdf PDF
National_Staff_Compensation_ _Pay_Groups.pdf PDF
Amendment_4.pdf PDF
REVISED_ATTACHMENT_J-3_(Financial_Display_by_Year).docx DOCX document
ATTACHMENT_J-1_(Student_Per_Day_Cost).docx DOCX document
REVISED_ATTACHMENT_J-1_(Cost_Detail).docx DOCX document
Amendment_3.pdf PDF
ATTACHMENT_J-2_(Statement_of_Financial_Capability).docx DOCX document
ATTACHMENT_J-1_(Student_Per_Day_Cost).docx DOCX document
Job_Corps__Foundation_Course_Curriculum_for_the_Health_Care_Industry.pdf PDF
List_of_All_Subject_Standards_for_Health_Care.pdf PDF
A_Guide_to_Standards-based_Instruction_in_Job_Corps.pdf PDF
ATTACHMENT_J-1_(Cost_Detail).docx DOCX document
ATTACHMENT_J-1_(Indirect_Cost).docx DOCX document
Amendment_2.pdf PDF
ATTACHMENT_J-7_(Past_Performance_Questionnaire).docx DOCX document
ATTACHMENT_J-1_(Fringe_Benefits).docx DOCX document
ATTACHMENT_J-3_(Financial_Display_by_Year).docx DOCX document
ATTACHMENT_J-6_(Subcontracting_Plan_Summary_Sheet).docx DOCX document
Standards-based_Education_ _Training_Implementation_Guide.pdf PDF
ATTACHMENT_J-8_(Statement_ _Acknowledgment).docx DOCX document
Amendment_1.pdf PDF
Sign-in_Sheet.pdf PDF
GSA_Vehicles.xls XLS spreadsheet
Master_Itemized_Property_Report.pdf PDF
National_Staff_Compensation_Table.pdf PDF
Utilities_and_Fuel_Usage.xlsx XLSX spreadsheet
Facility_Planning_Report_(Vol._1).pdf PDF
Inventory_Estimate.docx DOCX document
Solicitation_(RFP).docx DOCX document
Show all 40

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CASCADES

Job Corps Center Sedro-Woolley, WA

Facility Planning Report Volume II

Supporting Data

Preliminary December 2014

Department of Labor/ Office of Job Corps

CASCADES

Job Corps Center Sedro-Woolley, WA

Facility Planning Report Volume II

Supporting Data

Preliminary December 2014

Campus Green in front of Admin/Education/Med-Dental building 32

VOLUME I - PLANNING STRATEGY

Acronyms and Abbreviations Defi nition of Terms Executive Summary Exsting Site Plan Center Statistics Facility Survey Assement Results and Recommentdations

1.0 INTRODUCTIONS

• Objective and Scope

• Report Contents

2.0 EXISTING CONDITIONS

• Background

• Ownership

• General Site Conditions

• General Building Conditions

• Preventive Maintenance

• Facility Assessment by Function

• Environmental Management

• Resource Use/Conservation

• Sustainability

• Accessibility Standards

• Completed and Current Projects

• Health and Life Safety Issues

• Defi ciency Summary

3.0 PLANNING ANALYSIS

• Space Utilization Analysis

• Federal Real Property Assest Management

• Defi ciency Analysis

• Facility Condition Summary

• Building Condition by Function

• Planning Analysis Results and Conculsions

3.0 RECOMMENDATIONS

• Status of Previous Plan

• Proposed Plan

• Funded Not Corrected (FNC) Defi ciencies

• Summary of Proposed Plan

• Proposed Site Plan

• Implementation Plan

• Summary List of National Projects

• Project Data Sheets

Appendix A. Energy and Water Evaluation Report

VOLUME II - SUPPORTING DATA

Acronyms and Abbreviations Defi nition of Terms Executive Summary

1.0 SITE LAYOUT AND PLANS

• Location Map

• Exisiting Site Plan

2.0 DESCRIPTIONS

• Buildings and Structures

• Space Utilization By Function

• NSF by Building

• Environmental Management Report

• Asbestos Report

• Radon Report

• Site Descriptions

• Building Descriptions

3.0 DEFICIENCIES

APPENDICES - CORRESPONDENCE AND REPORTS

Appendix A.

• Survey Brief

• Student Questionnaire

Appendix B.

• Life Safety Defi ciencies and List

Appendix C.

• O&M Defi ciencies List

Appendix D.

• Active Warranty List

Appendix E.

• FRPC Performance Measures Matrix

Acronyms and Abbreviations

ACRONYMS AND ABBREVIATIONS

A Amperage ABAAS Architectural Barriers Act Accessibility Standard ACM Asbestos-Containing Materials AFUE Annual Fuel Utilization Efficiency AHU Air Handling Unit ANSI American National Standards Institute ARRA American Recovery and Reinvestment Act of 2009 BTU British Thermal Units\ CAA Clean Air Act CCF Hundred Cubic Feet CCTV Closed Circuit Television CDC Child Development Center CDC Centers for Disease Control and Prevention CDP Career Development Period CDSS Career Development Service System CFL Compact Fluorescent Light Bulbs CFM Cubic Feet per Minute CIS Center Information System CMA Certified Medical Assistant CMMS Computerized Maintenance Management System CMU Concrete Masonry Unit CAN Certified Nursing Assistant CO Carbon Monoxide CO Contracting Officer COR Contracting Officer’s Representative CPP Career Preparation Period CRA Construction, Rehabilitation, and Acquisition CTP Career Transition Period CTS Career Transition Services

CTST Career Technical Skills Training (formerly Vocational Skills Training [VST])

CW Cold Water CWA Clean Water Act DDC Direct Digital Controls DFAM Division of Facilities and Asset Management DOL Department of Labor EISA Energy Independence and Security Act of 2007 EMT Emergency Medical Technician

EMT Electrical Metal Tubing (Conduit) EO Executive Order EPA U.S. Environmental Protection Agency EPCRA Emergency Planning and Community Right-to-Know Act (1986) EPMD Ethylene Propylene Diene Terpolymer ESC Engineering Support Contractor ESCIS Engineering Support Contractor Information System ESL English as a Second Language oF Degrees Fahrenheit FACP Fire Alarm Control/Annunciator Panel fc Foot Candle FNC Funded Not Corrected FOP Financial Operating Plan FRPC Federal Real Property Council FY Fiscal Year GAO General Accounting Office GED General Educational Development GFCI Ground Fault Circuit Interrupter gph Gallons per Hour GSA General Services Administration GSF Gross Square Feet HID High Intensity Discharge HP Horsepower HSD High School Diploma HTW Hazard and Toxic Waste HVAC Heating, Ventilating, and Air Conditioning HW Hot Water IBC International Building Code IMC International Mechanical Code ION Inventory of Needs IPC International Plumbing code KBTU Thousand British Thermal Unit/Gross Square Foot/Year kV Kilovolt kVA Kilovolt-Amps kw Kilowatt JCC Job Corps Center JCDC Job Corps Data Center JCH Job Corps Handbook kWh Kilowatt Hours LAN Local Area Network LED Light Emitting Diode LF Linear Feet MBH Thousand BTUs per Hour MBTU Thousand British Thermal Unit MWH Megawatt Hour MC Mission Critical MCF Million Cubic Feet MDNC Mission Dependent, Not Critical MDP Main Distribution Panel MLO Main Lug Only m/s Meters/Second MTS Manual Transfer Switch NEC National Electric Code NEMA National Electrical Manufacturers Association NEPA National Environmental Protection Act NFPA National Fire Protection Association NMD Not Mission Dependent NSF Net Square Feet OA Outreach and Admissions OBS On Board Strength OCM Office of Contract Management OIG Office of Inspector General O&M Operations and Maintenance OSHA Occupational Safety and Health Administration PA Public Address pCi Picocurie PV Photovoltaic PVC Polyvinyl Chloride RCRA Resource Conservation and Recovery Act RTU Rooftop Unit SGA Student Government Association SHPO State Historic Preservation Office SF Square Feet SPCC Spill Prevention, Control and Countermeasure SST Social Skills Training T5 Fluorescent Lighting Designation (High Efficiency)

T8 Fluorescent Lighting Designation T12 Fluorescent Lighting Designation (Low Efficiency TSCA Toxic Substances Control Act of 1976 TV Television TVSS Transient Voltage Surge Suppression UEV Unevaluated UFAS Uniform Federal Accessibility Standards UL Underwriters Laboratories USDA U. S. Department of Agriculture V Volt VCR Video Cassette Recorder VST Vocational Skills Training W Watt WAN Wide Area Network WBL Work-Based Learning WIA Workforce Investment Act WIB Workforce Investment Board

Defi nition of Terms

DEFINITION OF TERMS

Accessibility: The degree to which a product, device, service, or environment is available to as many people as possible. Accessibility can be viewed as the "ability to access" and benefit from some system or entity. The Federal Government is required to comply with published law (Architectural Barriers Act (ABA) of 1968 , American Disabilities Act of 1990), regulations and related standards. Accessibility laws and standards have evolved over the past 12 years. DOL now follows ABA Accessibility Standards for Federal Facilities (ABAAS) adopted by the General Services Administration.

Annual Operating Cost: This FRPC performance measure reflects the cost to operate each used asset and consists of lease costs as well as costs related to recurring maintenance, utilities, janitorial, and roads and grounds expenses (Source: FRPC 2012).

Building: In accordance with the FRPC 2012 Guidance for Real Property Inventory Reporting, a building includes an enclosure for human occupancy that serves a variety of functions (food service, education, recreation, medical/dental, storage, administration) and is likely to have full utility services (heating, cooling, etc.). A building typically is over 400 square feet.

Building Condition Rating by Function: Each building is assigned a building condition based on the physical condition of the building and the impact on the functional use of the facility. Three ratings are possible:

Good: The facility condition is not impacting the facility function. A facility can have deficiencies and still be considered good.

Fair: The facility condition is impacting the facility function and deficiencies are limited to less than 30% of the replacement value. Correction of the deficiencies would allow the facility to return to a good status.

Poor: The facility condition is significantly impacting the facility function and/or deficiencies are more than 30% of the replacement value. Generally a poor rating indicates a “gut renovation or total replacement/demolition would be required.

Building/Structure Ratings: Each building is rated according to three ratings (good, fair, and poor) based on evaluations of the structure, exterior, interior, mechanical, and electrical elements. Three ratings are possible:

Good: The facility condition is not impacting the facility function. A facility can have deficiencies and still be considered good.

Fair: The facility condition is impacting the facility function and deficiencies are limited to less than 30% of the replacement value. Correction of the deficiencies would allow the facility to return to a good status.

Poor: The facility condition is significantly impacting the facility function and/or deficiencies are more than 30% of the replacement value. Generally a poor rating indicates a “gut renovation or total replacement/demolition would be required

Construction Type: The International Building Code (IBC) construction classifications include the following:

Type I and II. Those types of construction in which building elements are of noncombustible materials, except as permitted in Section 603 and elsewhere in the code.

Type II and III. Any type of construction where the exterior walls are of noncombustible material and the interior building elements are of any material permitted by the code.

Type IV. This type (heavy timber, HT) is where the exterior walls are of noncombustible material and the interior building elements are of solid or laminated wood without concealed spaces.

Type V. That type of construction where structural elements, exterior walls, and interior walls are of any materials permitted by the code.

Contract Strength: The authorized number of students at a Center in accordance with the contract between the Region and Center Operator.

Deficiency: A deficiency at a Center represents the spectrum of conditions related to the Center’s mission and/or its physical, functional, or operational features do not meet related goals, standards, codes, or other measures of acceptability. Each deficiency at a JCC or CCC initially is categorized as one of the following three deficiencies: Program, Site, or Building:

Program: Program deficiencies address issues such as square footage shortages or the omission of amenities required or standard for the proper operation of a particular Job Corps function.

Site: Site deficiencies indicate adverse site and infrastructure conditions which negatively impact operations and environment (e.g., site lighting, sidewalks, roads, etc.)

Building: Building deficiencies indicate adverse conditions at the building level.

This element includes the substructure, shell, interior, services (plumbing, HVAC, fire protection, and electrical), and equipment and furnishings.

Deficiency Classifications (I to IV): Deficiency classifications are defined as follows:

Class IA - Deficiencies which address imminent life safety and health hazards.

Class II - Deficiencies which address code violations, however, do not represent imminent life safety and health hazards.

A - Deficiencies which violate code (Federal, State or Local) and may result in an interruption of center operations if not corrected.

B - Deficiencies which violate code (Federal, State or Local) and have no immediate impact on center operations if not corrected.

C- Deficiencies which are not in compliance for accessibility in accordance with the Architectural Barriers Act (ABA), Americans with Disabilities Act (ADA), Uniform Federal Accessibility Standards (UFAS), or other applicable standards.

Class III - Deficiencies which address facility repair, replacement or maintenance.

A - Deficiencies which if not corrected may result in an interruption of center operations.

B - Deficiencies which if not corrected will have minimal impact on center operations or can be mitigated through temporary measures until the deficiency is corrected.

Class IV – Deficiencies which address programmatic needs.

A - Deficiencies which if corrected produce substantial improvements in the quality of the learning and living environment.

B - Deficiencies which if corrected are desirable enhancements.

Deficiency Funding Status: The status of the deficiency included the following categories:

Funded deficiencies report indicates the funding year for funded Regional projects, which have dollar amounts shown, or deficiencies assigned to funded National and Regional projects without dollar amounts. Major Regional projects are equivalent to National projects but assigned to the Federal agency (e.g., U.S.

Department of Agriculture) that acts as the Center operator. All operations and maintenance (O&M) deficiencies are treated as funded through the Center Operators O&M contract within the Region.

Proposed deficiencies have been assigned to a proposed future National project.

Unfunded deficiencies are Regional projects unless or until they are assigned to a National project.

Deficiency Status: The deficiency status is tracked and updated during the three-year facility survey cycle, or as such deficiencies are corrected and reported. The status includes:

Uncorrected: Once a deficiency is identified, documented, reported, and assigned for correction, the deficiency remains uncorrected until such time that the deficiency is corrected, reported, and verified.

Corrected: A corrected deficiency is one that has been assigned, funded, corrected, reported, and verified. Typically, the ESC verifies completion of the deficiency through the facility survey or site visit. The Center also may report completion and provide verifiable evidence of the correction, subject to review by the ESC.

Funded Not Corrected: A deficiency that has been approved and authorized as a regional project through the CRA budget, emergency or supplemental funding, or the Life Safety Memo. Note: the funding may not have reached the Center yet as the first steps are a FOP allocation by the National Office and a contract modification by the Region.

No Longer Needed: A no longer needed deficiency is one that has been approved and funded as a Regional project, but due to subsequent circumstances, has been reported by the Center as no longer being required to be accomplished. This type of deficiency is verified and confirmed by the ESC and removed from the Funded Not Corrected deficiency category. The Center should take action with its Region to return the funds.

Facility Condition Index: This performance measure reflects the condition of each asset by comparing the current repair needs to the replacement value of the asset. The index is expressed as a percentage, with 100% being a facility with no repair needs.

Gross Square Foot: The sum of all areas on all floors of a building included within the outside faces of its exterior walls, including all vertical penetration areas, for circulation and shaft areas that connect one floor to another. Gross Area is computed by physically measuring or scaling measurements from the outside faces of exterior walls, disregarding cornices, pilasters, buttresses, etc., that extend beyond the wall faces. Exclude areas having less than a 3-foot clear ceiling height unless the criteria of a separate structure are met. Measured in terms of Gross Square Feet (GSF): GSF = Net Usable Area + Structural Space (Source: http://nces.ed.gov/pubs2006/ficm/).

Mission Dependency: The value an asset brings to the performance of the mission as determined by the governing agency. Specific elements of this category include (FRPC 2012):

Mission Critical - – Without constructed asset or parcel of land, mission is compromised.

Mission Dependent, Not critical (MDNC) - Does not fit into Mission Critical or Not Mission Dependent categories.

Not Mission Dependent (NMD) – Mission unaffected

Ownership (Owned vs Leased): If the property is owned, the Federal Government has fee simple interest for the real property asset. If the property is leased, the rights to use the asset are assigned to the Federal Government by a private entity or a non-Federal Government entity for a defined period of time in return for rental payments (FRPC 2012).

National Project: Generally large and complex projects that require professionally prepared drawings and specifications that are time phased (design and construction) and contracted by the DOL National Office.

Net Square Foot: The sum of all areas on all floors of a building assigned to, or available for assignment to, an occupant or specific use. This value is computed by physically measuring or scaling measurements from the inside faces of surfaces that form the boundaries of the designated areas. Exclude areas having less than a 3-foot clear ceiling height unless the criteria of a separate structure are met. Included should be major space use categories for assignable space (e.g., dormitories, education, recreation, etc.) that are used to accomplish the institution’s mission. Net Square foot: NASF = Sum of Areas Designated by the Major Space Use Categories (Source: http://nces.ed.gov/pubs2006/ficm/).

On Board Strength (OBS): The actual number of students on Center on a day to day basis.

Preventive Maintenance: The care and servicing by personnel for the purpose of maintaining equipment and facilities in satisfactory operating condition by providing for systematic inspection, detection, and correction of incipient failures either before they occur or before they develop into major defects (Source: Dictionary of Military and Associated Terms, US DOD 2005).

Property Type: Indicates the asset as one of the following categories of real property:

land, building, structure.

Property Use: Since the elements defined by the FRPC do not match the space use codes employed in ESCIS, a mapping procedure will be created to align the definitions.

In the report, the Federal Real Property Council (FRPC) classifications will be printed for display. The information is available through the property registration field of Engineering Support Contractor Information System (ESCIS), and the current ESCIS designations will be correlated to the FRPC designations as follows:

ESCIS FRPC

Dormitory Dormitories/Barracks Food Service Other Institutional Uses Education School Recreation Other Institutional Uses Medical/Dental Other Institutional Uses Storage Warehouse Administration Office Structure * Storage, Service, Utility

Systems, or Other Land Institutional

* Each structure will be entered manually from the ESCIS database into one of four FRPC categories listed opposite the term “structure”.

Replacement Value: The cost of replacing the existing constructed asset at today’s building standards. It is the amount required to construct an asset of similar size and in the same location at today’s construction standards. The replacement value reported must be greater than zero (FRPC 2012).

Regional Office Project: Generally smaller projects where the funds will be transferred to the region for center execution.

Structure: In accordance with the FRPC 2012 Guidance for Real Property Inventory Reporting, a structure serves to provide storage, service, utility systems and is not likely to have full utilities (heating, cooling, etc.). A structure typically is less than 400 square feet.

Sustainability: Formally known as the World Commission on Environment and Development, the Brundtland Commission's mission in the 1980s was to unite countries to pursue sustainable development. The Commission defined sustainability as the “development which meets the needs of current generations without compromising the ability of future generations to meet their own needs".

Sustainability also is defined as the creation or enhancement of environmental, economic, and social-cultural balance, as realized through business activities, individual actions, and community engagement. Sustainability addresses approaches, methods and practices that optimize the use of energy, water, and materials while reducing greenhouse gas emissions.”

Utilization: This performance measure assesses the degree to which each asset is utilized and is expressed as a percentage. It is calculated on a square footage basis, comparing the square footage used to the “design square footage” based on contract strength (Source: FRPC 2012).

Executive Summary

The facility survey for the Cascades JCC was completed June 23 to June 27, 2014.

The information presented in Volume II, Supporting Data, represents the current status of the campus.

The information includes the following:

Existing site layout Overall status of existing building and structures Space utilization by building and function compared to recommended standards Status of environmental elements of the Center’s operations Details on the site and buildings and structures based on architectural, electrical, and mechanical survey and supporting documentation Presentation of the status of historical deficiencies and compilation of deficiencies documented through this survey Supporting documentation, as presented in the appendices of the center review meeting; survey brief and student questionnaire; life safety IA/IIA transmittal;

active warranties; and Federal Real Property Council (FRPC) Measures Matrix

Section 1.0 of this volume addresses site layout and plans while Section 2.0 presents details on the buildings and structures. Section 3.0 presents historic deficiencies and their status as well as new ones identified in this survey. The appendices provide additional information as noted below:

Appendix A. Survey Brief Questionnaire Appendix B. Life Safety Deficiencies and List Appendix C. O&M Deficiencies List Appendix D. Active Warranty Report Appendix E. FRPC Performance Measures Matrix

EXECUTIVE SUMMARY

1.0 - Site Layout and Plans

CASCADES

JOB CORPS CENTER

SEDRO-WOOLLEY, WASHINGTON

CASCADES JCC

10 MI5 0

2.0 - Descriptions

2.0 DESCRIPTIONS

In this section, the following information on the Center and its buildings and structures is presented in tabular format:

Building and Structures – This table indicates the building type, asset number, name, use group, gross square footage (GSF), construction year, number of floors, number of sleeping room and number of beds, construction type (noted as numerical values instead of code-specified Roman numerals), status (active or closed), and overall condition. The possible International Building Code (IBC) construction classifications include the following:

Type I and II. Those types of construction in which building elements are of noncombustible materials, except as permitted in Section 603 and elsewhere in the code.

Type III. This type of construction is where the exterior walls are of noncombustible material and the interior building elements are of any material permitted by the code.

Type IV. This type (heavy timber, HT) is where the exterior walls are of noncombustible material and the interior building elements are of solid or laminated wood without concealed spaces. Fire-retardant-treated wood framing complying with IBC section 2303.2 shall be permitted within exterior wall construction with a 2-hour rating or less.

Type V. That type of construction where structural elements, exterior walls, and interior walls are of any materials permitted by the code.

The overall building/structure condition is rated in one of three categories: good, fair, or poor.

Space Utilization by Function - This table compares the DOL recommended net square footage per enrollee and for the total function (e.g., housing, education, food service, recreation, medical/dental, administration, storage/support) to the actual values.

Net Square Footage by Building - This table compares the DOL recommended net square footage for the buildings with the function (e.g., housing, education, food service, recreation, medical/dental, storage/support) to the actual values and presents a percentage difference in the two values. In some instances, a recommended value is not available for sub-elements of a function; therefore, the recommended value is shown as “0”.

Environmental Management Report – This table summarizes regulatory related solid and hazardous waste information in accordance with the Resource Conservation and Recovery Act (RCRA) and the presence or absence of hazardous material storage facilities in accordance with Emergency Planning and Community Right-to-Know Act of

1986 (EPCRA). An inventory of petroleum storage tanks is noted as well as asbestos and polychlorinated biphenyls (PCBs) in accordance with the Clean Water Act (CWA) and Toxic Substance Control Act (TSCA), respectively. In addition, this report statuses air quality as required under the Clean Air Act (CAA).Any radon testing of buildings also is documented.

Site Descriptions – Tabular information is documented for the site. Among the data presented are the topography; total number of buildings and structures; roads, parking and sidewalks; fencing; site utilities; storage tanks; accessibility; historic preservation;

natural hazards; and sustainability. The overall condition of the site is rated in one of three categories: good, fair, or poor.

Building Descriptions – Tabular information, as well as photographs and floor plan drawings, are provided for each building or structure, as appropriate, in the following categories: real estate; accessibility; building envelope; interior finishes; vertical circulation; heating, ventilation and air conditioning (HVAC); plumbing; fire protection;

electrical services; fire alarms; carbon monoxide detection; communication; and building metering. The overall condition of the building and its five key subsystems (structure, exterior, interior, mechanical, and electrical) are rated in one of three categories: good, fair, or poor. If applicable, recommendations for renovation or demolition are provided.

BUILDINGS AND STRUCTURES

01003 CASCADES 12/10/2014

1Page: of Date:

0010 - RECREATION/GYMNASIUM

0012 - MOUNT RAINIER DORMITORY

0013 - DINING HALL/CULINARY ARTS

0015 - ACADEMICS/EVERGREEN

DORMITORY

0016 - CHALLENGER DORMITORY

0017 - WHITEWATER DORMITORY

0024 - CAREER TRANSITION

0025 - DENTAL ASSISTANT

0026 - VOCATIONAL STORAGE

0027E - WAREHOUSE/RECEIVING

0027W- FMC/MED ASSIST/MED OFFICE

SPEC/HEALTH OCC

0028 - CENTER MAINTENANCE SHOP

0029 - FLAM STOR/CENTER SUPPORT

0030 - CULTURAL CENTER

0031 - VOCATIONAL BLDG.

0032 - ADMIN/EDUCATION/MED-DENT

0033A - SAFETY/STORAGE

0033B - MENTAL HEALTH MEETING

ROOM

0034 - SECURITY/SAFETY

0048 - LRC/LIBRARY

0050 - CEMENT MASONRY

0057 - BUSINESS/CLERICAL

0063 - CENTER MAINTENANCE

STORAGE

0051 - CARPENTRY P.E.T.S. (74FT X

25FT)

0052 - STORAGE (8FT X 10FT)

0053 - STORAGE (8FT X 15FT)

0054 - CARPENTRY STORAGE (24FT X

64FT)

0055 - CARPENTRY MOCK-UP (14FT X

20FT)

0056 - ELECTRICAL MOCK-UP (15FT X

25FT)

0057A - GAZEBO (15FT DIAMETER)

0057B - GAZEBO (15FT DIAMETER)

0057C - GAZEBO (15FT DIAMETER)

0057D - GAZEBO (15FT DIAMETER)

0057E - PAVILION (35FT DIAMETER)

0057F - PAVILION (35FT DIAMETER)

0057G - PAVILION (13FT X 30FT)

0058 - CARPORT (20FT X 30FT)

0059 - CEMENT MASONRY MOCK-UP

(16FT X 30FT)

0061 - STORAGE (7FT X 8FT)

0062 - STORAGE (12FT X 20FT)

0064 - GREENHOUSE (25FT X 44FT)

0065 - TRANSFORMER BUILDING (8FT X

8FT)

Name GSF

15,740 17,560 26,880 17,560

18,220 29,800 2,100 2,100 7,500

12,750 13,230

3,600 1,590

11,040 13,980 31,240 1,140

1,010 1,850 1,800 1,580 1,200

1,850

1,560

1,050 1,050

1,100

Active Active Active Active

Active Active Active Active Active Active Active

Active Active Active Active Active Active Active

Active Active Active Active Active

Active

Active Active Active

Active

Active

Active Active Active Active Active Active Active Active Active

Active Active Active Active

StatusType

Building Building Building Building

Building Building Building Building Building Building Building

Building Building Building Building Building Building Building

Building Building Building Building Building

Structure

Structure Structure Structure

Structure

Structure

Structure Structure Structure Structure Structure Structure Structure Structure Structure

Structure Structure Structure Structure

Use Group Built Flrs Const

Assembly Residential Assembly Residential

Residential Residential Business Business Storage Storage Business

Business Storage Assembly Business Business Business Business

Business Business Business Business Storage

Storage

Storage Storage Storage

Storage

Business

Assembly Assembly Assembly Assembly Assembly Assembly Assembly Storage Business

Storage Storage Utility/Misc.

Utility/Misc.

Good Good Good Good

Good Good Good Good Good Good Good

Good Good Good Good Good Good Good

Good Good Good Good Good

Good

Fair Good Good

Fair

Good

Good Good Good Good Good Good Good Poor Good

Good Good Good Good

ConditionAsset Number

0100300002 0100300003 0100300004 0100300005

0100300006 0100300007 0100300008 0100300009 0100300019 0100300010 0100300029

0100300011 0100300012 0100300013 0100300014 0100300015 0100300018 0100300023

0100300016 0100300030 0100300026 0100300027 0100300028

0100300024

0100300031 0100300032 0100300025

0100300034

0100300035

0100300036 0100300037 0100300038 0100300039 0100300040 0100300041 0100300033 0100300022 0100300043

0100300042 0100300021 0100300020 0100300045

BUILDINGS AND STRUCTURES

01003 CASCADES 12/10/2014

2Page: of Date:

0067 - ELECTRICAL MOCK-UP (20FT X

21FT)

Name GSF

525 Active

StatusType

Structure

Use Group Built Flrs Const

Business 2004 1 5 Good

ConditionAsset Number

0100308014

23 234,050

20 10,360

43 244,410

Buildings

Structures

Total

GSF

GSF

GSF

Summary

12/10/2014

Space Utilization By Function 01003 Cascades Page: 1 of Date:

HOUSING

EDUCATION

FOOD SERVICE

SUGGESTED

NSF/

ENROLLEE

SUGGESTED

TOTAL

NSF

ACTUAL

TOTAL

NSF

TYPE OF SPACE

SUB TOTAL

SUB TOTAL

SUB TOTAL

Resident Men Resident Women Total Residents

Residents 340 Non Residents 0

340Total Students

(340)

(340)

(340)

DIFFERENCE

36,720

24,130

8,840

43,265

60,611

13,508

Lounge Other Shower/Toilet Sleeping excl. SPD( rooms; beds) Storage

Academic (340) Non-Academic

36 -- ACT (Off-Ctr) 30 -- Business Office Technologies 40 -- Carpentry + 20 -- Cement Masonry + 60 -- Cert. Nursing Asst.

20 -- Culinary Arts + 24 -- Facilities Maint. and Const. + 30 -- Medical Assistant 30 -- Medical Office Specialist 30 -- Office Administration 24 -- Painting +

Vocational Theory (128)

Dining (1 Serving) Food Preparation Food Storage

5,330 3,947 5,353

25,381 3,254

10,793 8,893

1,466 9,208 7,106 3,812 2,186 6,451 3,171 1,806

3,878

1,841

5,772 5,573 2,163

3,400 2,720 4,080

24,480 2,040

3,400 3,400

1,200 3,000 1,500 2,400 1,200 1,800

1,350 1,800

1,280

5,440 2,040 1,360

1,930 1,227 1,273

1,214

7,393 5,493

6,208 5,606 1,412

4,651 2,271

-1,350 2,078

3,533

Vocations

6,545

36,481

4,668

12/10/2014

Space Utilization By Function 01003 Cascades Page: 2 of Date:

RECREATION

MEDICAL/DENTAL

ADMINISTRATION

STORAGE/SUPPORT

VACANT

SUGGESTED

NSF/

ENROLLEE

SUGGESTED

TOTAL

NSF

ACTUAL

TOTAL

NSF

TYPE OF SPACE

SUB TOTAL

SUB TOTAL

SUB TOTAL

SUB TOTAL

SUB TOTAL

TOTAL 306 104,040 168,659

(340)

(340)

(340)

(340)

(0)

DIFFERENCE

234,050

0.72

TOTAL GSF

NET TO GROSS RATIO

17,000

3,750

6,800

6,800

15,903

5,067

10,063

19,031

1,211

Arts & Crafts Gymnasium Pool Hall Recreation Office Recreation Room Recreation/Snack Bar T.V. Room Weight Room

Medical Only Medical/Dental

Administration

Operations & Maintenance Warehouse

Vacant

4.94 6.09

1,463 7,770 1,970 1,638

1,395

4,682

10,063

2,570 16,461

1,211

1,680 2,070

6,800

2,720 4,080

1,463 7,770 1,970 1,638

1,395

-1,295 2,612

3,263

-150 12,381

1,211

RESIDENT

NON-RESIDENT

(340)

(0) 15

50 17,000

-1,097

1,317

3,263

12,231

1,211

64,619

Net Square Footage By Building Date: 12/10/2014 Page: 1

Center: CASCADES (01003) of 4

HOUSING

Sleeping excl. SPD

Lounge

Storage

Shower/Toilet

Other

Function Suggested

NSF

6,670 8,049 7,366 3,296

1,202

2,118 1,438

1,497

1,160

1,074 2,150 1,468

1,139 1,758

0012 - MOUNT RAINIER DORMITORY

0017 - WHITEWATER DORMITORY

0016 - CHALLENGER DORMITORY

0015 - ACADEMICS/EVERGREEN DORMITORY

0012 - MOUNT RAINIER DORMITORY

0015 - ACADEMICS/EVERGREEN DORMITORY

0017 - WHITEWATER DORMITORY

0016 - CHALLENGER DORMITORY

0017 - WHITEWATER DORMITORY

0015 - ACADEMICS/EVERGREEN DORMITORY

0016 - CHALLENGER DORMITORY

0012 - MOUNT RAINIER DORMITORY

0012 - MOUNT RAINIER DORMITORY

0017 - WHITEWATER DORMITORY

0016 - CHALLENGER DORMITORY

0015 - ACADEMICS/EVERGREEN DORMITORY

0015 - ACADEMICS/EVERGREEN DORMITORY

0016 - CHALLENGER DORMITORY

0012 - MOUNT RAINIER DORMITORY

0017 - WHITEWATER DORMITORY

Bldg Name Actual NSF Difference

25,381

5,330

3,254

5,353

3,947

Sub Total: 43,265

24,480

3,400

2,040

4,080

2,720

36,720

1,930

1,214

1,273

1,227

( 340

6,545 rooms; beds rooms; beds rooms; beds rooms; beds

Page: 2

Center: CASCADES (01003) of 4

EDUCATION

Academic

Vocational Theory (128)

Carpentry

Cement Masonry

Culinary Arts

Painting

Facilities Maint. and Const.

Medical Assistant

Non-Academic

Business Office Technologies

Medical Office Specialist

Function Suggested

NSF

2,231 4,770

2,226

1,841

4,337 2,807 2,064

1,627 3,505 1,974

2,186

1,426 2,452

2,585 3,044

1,600 1,571

2,002

2,089 1,746

1,354

1,466

1,806

0032 - ADMIN/EDUCATION/MED-DENT

0015 - ACADEMICS/EVERGREEN DORMITORY

0032 - ADMIN/EDUCATION/MED-DENT

0032 - ADMIN/EDUCATION/MED-DENT

0032 - ADMIN/EDUCATION/MED-DENT

0032 - ADMIN/EDUCATION/MED-DENT

0031 - VOCATIONAL BLDG.

0031 - VOCATIONAL BLDG.

0026 - VOCATIONAL STORAGE

0030 - CULTURAL CENTER

0050 - CEMENT MASONRY

0031 - VOCATIONAL BLDG.

0026 - VOCATIONAL STORAGE

0013 - DINING HALL/CULINARY ARTS

0031 - VOCATIONAL BLDG.

0026 - VOCATIONAL STORAGE

0030 - CULTURAL CENTER

0027W- FMC/MED ASSIST/MED OFFICE SPEC/HEALTH OCC

0031 - VOCATIONAL BLDG.

0025 - DENTAL ASSISTANT

0027W- FMC/MED ASSIST/MED OFFICE SPEC/HEALTH OCC

0024 - CAREER TRANSITION

0048 - LRC/LIBRARY

0048 - LRC/LIBRARY

0032 - ADMIN/EDUCATION/MED-DENT

0017 - WHITEWATER DORMITORY

0033A - SAFETY/STORAGE

0031 - VOCATIONAL BLDG.

0057 - BUSINESS/CLERICAL

0027W- FMC/MED ASSIST/MED OFFICE SPEC/HEALTH OCC

Bldg Name Actual NSF Difference

10,793

1,841

9,208

7,106

2,186

3,878

6,451

3,171

8,893

1,466

1,806

3,400

1,280

3,000

1,500

1,200

1,800

1,800

3,400

1,200

7,393

6,208

5,606

2,078

4,651

2,271

5,493

( 340 )

Page: 3

Center: CASCADES (01003) of 4

EDUCATION

FOOD SERVICE

RECREATION

MEDICAL/DENTAL

Cert. Nursing Asst.

Food Preparation

Food Storage

Dining (1 Serving)

Arts & Crafts

Gymnasium

Weight Room

Pool Hall

Recreation/Snack Bar

Recreation Room

T.V. Room

Recreation Office

Medical/Dental

Medical Only

Function Suggested

NSF

3,812

5,573

2,163

5,772

1,463

7,770

1,395

1,970

1,109

4,192

0027W- FMC/MED ASSIST/MED OFFICE SPEC/HEALTH OCC

0013 - DINING HALL/CULINARY ARTS

0013 - DINING HALL/CULINARY ARTS

0013 - DINING HALL/CULINARY ARTS

0010 - RECREATION/GYMNASIUM

0010 - RECREATION/GYMNASIUM

0010 - RECREATION/GYMNASIUM

0030 - CULTURAL CENTER

0030 - CULTURAL CENTER

0030 - CULTURAL CENTER

0030 - CULTURAL CENTER

0010 - RECREATION/GYMNASIUM

0030 - CULTURAL CENTER

0033B - MENTAL HEALTH MEETING ROOM

0032 - ADMIN/EDUCATION/MED-DENT

0033A - SAFETY/STORAGE

Bldg Name Actual NSF Difference

3,812

5,573

2,163

5,772

1,463

7,770

1,395

1,970

1,638

4,682

Sub Total:

Sub Total:

Sub Total:

Sub Total:

60,611

13,508

15,903

5,067

2,400

2,040

1,360

5,440

2,070

1,680

22,780

8,840

17,000

3,750

1,412

3,533

2,612

-1,295

37,831

4,668

-1,097

1,317

Page: 4

Center: CASCADES (01003) of 4

ADMINISTRATION

STORAGE/SUPPORT

VACANT

Administration

Warehouse

Operations & Maintenance

Vacant

Function Suggested

NSF

8,758

11,899 3,742

1,025 1,545

1,211

0027E - WAREHOUSE/RECEIVING

0032 - ADMIN/EDUCATION/MED-DENT

0034 - SECURITY/SAFETY

0033A - SAFETY/STORAGE

0027E - WAREHOUSE/RECEIVING

0028 - CENTER MAINTENANCE SHOP

0027W- FMC/MED ASSIST/MED OFFICE SPEC/HEALTH OCC

0063 - CENTER MAINTENANCE STORAGE

0029 - FLAM STOR/CENTER SUPPORT

0013 - DINING HALL/CULINARY ARTS

Bldg Name Actual NSF Difference

10,063

16,461

2,570

1,211

Sub Total:

Sub Total:

Sub Total:

10,063

19,031

1,211

6,800

4,080

2,720

6,800

6,800

3,263

12,381

-150

1,211

3,263

12,231

1,211

Environmental Management Report Center: CASCADES (01003)

Page: 1 Date: 12/10/2014 of 1

SOLID & HAZARDOUS WASTE MANAGEMENT (RCRA)

Commercial Waste Service

HAZARDOUS MATERIALS STORAGE (EPCRA)

Yes Building 29

Oil-based paint (200 gals), organic solvent (100 gals), propane (250 gals) Yes

PETROLEUM UNDERGROUND STORAGE TANKS (RCRA)

N/A0

PETROLEUM ABOVEGROUND STORAGE TANKS (CWA)

ASBESTOS AND PCB MANAGEMENT (TSCA)

AIR POLLUTION CONTROL (CAA)

N/A None

Attainment

Solid Waste Disposal :

Hazardous Waste Generator :

Hazardous Waste ID :

Generator Classification :

Hazadous Materials Storage :

Hazardous Materials ID :

HazMat Storage Area :

HazMat Spill Response Plan :

Number of Regulated USTs :

Number of Un-regulated USTs :

Local Hazardous Use Permit :

LEPC Notification :

EPA Generator ID Number :

Hazardous Waste Disposal :

RCRA Compliance

ID LocationFuel Type Capacity

Number of ASTs :

Asbestos Survey Date :

Asbestos Type :

Asbestos Coordinator :

Coordinator Training Date:

Custodial/Maintenance Training :

AHERA Regulated :

Management Plan Approval :

PCB Transformer Testing :

PCB Transformers :

PCB-Contaminated Transformers :

Transformers Labelled :

Regional Air Quality :

Permitted Air Pollution Source :

Source Description :

Rural Skagit Sanitation Yes Organic solvent (< 25 gals/month)

Conditionally Exempt Small Quantity Generator N/A Commercial Hazardous Waste Disposal Service

Various licensed contractors

No No

Overfill Leak Corrosion

SPCC Plan Required : SPCC Plan Completed :

No N/A

01/17/1991 Friable/Non-Friable Dan Singleton

Yes No N/A Yes Yes

ID Fuel Type Capacity Location Overfill

Prevention Secondary Containment

1 Petroleum - Gasoline 500 Near Building 26 Yes Yes

Tank Status Active

Tank Status Prevention/Detection

Asbestos-Containing Materials Inventory

Date: 12/10/2014Center : Cascades (01003) Page: 1 of 2

Roof Repair/Replacement Floor Finishes Floor Finishes

Floor Finishes Floor Finishes Floor Finishes Floor Finishes

Roof Repair/Replacement

Floor Finishes Floor Finishes

Wall Finishes Floor Finishes Roof Repair/Replacement

Floor Finishes

Bldg System

Bldg System

Bldg System

Bldg System

Bldg System

Bldg System

Roof flashing 9x9 floor tile, brown/white 12x12 floor tile, brown/tan

9x9 floor tile, gray 9x9 floor tile, tan 12x12 floor tile, brown/white 9x9 floor tile, tan/black

Roofing felt

12x12 flr. tile, tan (covered) 12x12 floor tile, tan

Asbestos cement board 12x12 floor tile, tan Roof flashing

12x12 floor tile, tan

Category Description

Category Description

Category Description

Category Description

Category Description

Category Description

Sq. Ft.

Sq. Ft.

Sq. Ft.

Sq. Ft.

Sq. Ft.

Sq. Ft.

Sq. Ft.

Sq. Ft.

Sq. Ft.

Sq. Ft.

Sq. Ft.

Sq. Ft.

Sq. Ft.

Sq. Ft.

Location

Location

Location

Location

Location

Location

Unit

Unit

Unit

Unit

Unit

Unit

Quantity

Quantity

Quantity

Quantity

Quantity

Quantity

Around vent stacks Hallway, arts/crafts Weight room office

Lobby storage room 1st fl. closet, SW Stairwell landings 1st fl. jan. closet

Culinary arts roof

Dorm rooms, hallways 1st fl. jan. closet

Plaster vocation Bathroom, office Around vent stacks

Bathroom, paint shop

12000

10000

Building :

Building :

Building :

Building :

Building :

Building :

0010 - RECREATION/GYMNASIUM

0012 - MOUNT RAINIER DORMITORY

0013 - DINING HALL/CULINARY ARTS

0016 - CHALLENGER DORMITORY

0027W- FMC/MED ASSIST/MED OFFICE SPEC/HEALTH O

0031 - VOCATIONAL BLDG.

Asbestos-Containing Materials Inventory

Page: 2 of 2

Floor Finishes Floor Finishes Floor Finishes Floor Finishes Floor Finishes Heating Roof Repair/Replacement

Floor Finishes

Bldg System

Bldg System

12x12 floor tile, gray 12x12 floor tile, tan 9x9 floor tile, green 9x9 floor tile, green/white 9x9 floor tile, tan/gray Pipe fitting insulation Roof flashing

9x9 floor tile, tan/red

Category Description

Category Description

Sq. Ft.

Sq. Ft.

Sq. Ft.

Sq. Ft.

Sq. Ft.

Ea.

Lin. Ft.

Sq. Ft.

Location

Location

Unit

Unit

Quantity

Quantity

Storage/Support Vocational office Medical hallway East wing Southwest wing Storage/Support Rooftop HVAC units

Detention/isolation

14000 12500

Building :

Building :

0032 - ADMIN/EDUCATION/MED-DENT

0034 - SECURITY/SAFETY

Site Description

Satellite View of the Campus

Page: 1 Date: 12/10/2014 of 4

Comments:

Paving Type for Roads & Parking

A gravel road loops around Building 33A. Parking areas located between Administration Building 32 and Vocational Building 31 and near Dining Hall Building 13 and dormitory buildings are concrete. The visitor parking at west side of Security Building 34 is compacted dirt road.

Paving Type for Sidewalks

Asphalt Concrete

Comments:

Topography Buildings and Structures

Center is not fully enclosed by fencing. Center is not fully enclosed by fencing. A chain link fence with lockable gates secures the area of vocational buildings at the north-east side of campus. The site has an abundance of mature trees and well maintained green space and other plantings.

ROADS, PARKING & SIDEWALKS

Water Source Water Authority Service Meter On-Site Treatment Plant

1. Water System

Treatment Type Storage Type Storage Capacity(Gallons)

NoIndividualSkagit County Public Utility District No. 1.Public Water Authority

None 0None

Water is metered at 8 locations for Job Corps buildings.Comments:

Comments:

Fire Hydrants On-Site Water Supply Storage Capacity

(Gallons) Pressure Source FD Response Time (Minutes)

Yes 0 8None Municipal

Nearest fire station is Sedro Woolley Fire Department, approximately 4 miles from the center.

Fire Station Response time is 8 minutes.

Number of Deficiencies = 3

Number of Deficiencies = 1

SITE FEATURES

UTILITIES

2. Fire Protection System

Buildings Structures23 20Flat

Surrounding

Outdoor Recreation

Forest

Basketball, Football, Soccer, Soft/Baseball, Swing Set, Volleyball Retention Pond, Two Bioswales, Underground Utility Tunnel System

Vocations Chain Link

Location Type

Maintenance Responsibility System Capacity Adequate System Condition

Lessor Lessor Yes Good

Separate Loop

No

Ownership Maintenance Responsibility System Capacity Adequate System Condition

Lessor Lessor Yes Good

Ownership

Roads & Parking Adequate Roads & Parking Condition Sidewalks Adequate Sidewalk Condition Yes Fair Yes Good

Fencing

Other Features

Page: 2 Date: 12/10/2014 of 4

Sewage Treatment Flow

Utility

Publicly Owned Treatment Works

Lessor

Gravity

Maintenance ResponsibilityOwnership

Comments: Propane is provided by Amerigas.

Cascade Natural Gas Corporation

Comments: Steam is provided to the center buildings from the on-site Lessor-operated power plant (Bldg. 19). At most center buildings, the steam is converted to hot water and used for space heating.

3. Sanitary Sewer System/ Sewage Treatment Plant

5. Fuel Distribution System

6. Central Plant

System Capacity Adequate System Condition

Yes Good

4. Storm Water System Number of Deficiencies = 7

Drain Type On-Site Storm Water Management

Underground Retention Pond

Ownership Maintenance Responsibility System Capacity Adequate System Condition

Lessor Yes GoodLessor

Gas Company Metering

Master

Ownership Maintenance Responsibility System Capacity Adequate System Condition

Lessor Lessor Yes Good

Type Energy Source

Steam Natural Gas Most Cascades JCC buildings.

Bldgs Served

Ownership Maintenance Responsibility Plant Capacity Adequate Plant Condition

Lessor Lessor Yes Unknown

Page: 3 Date: 12/10/2014 of 4

Comments:

Electric Company PCB Trans.

Transformer Mounting Transformer Ownership

Systems Ownership Maintenance Responsibility

Puget Sound Energy (PSE)

Service is brought to the center from the main switchgear located in the lessor's power house. The 4.16/2.4 kV lines are routed through a loop of transformer vaults which are either above ground or underground in the tunnel. From these vaults the secondary 120/208V, 3-phase, 4 wire system is distributed to DOL leased buildings via their respective service disconnects and/or main distribution panels. Some buildings have their own meter while others are zone-metered. Dining Hall Building 13 and Dormitory Buildings 12, 15, 16 and 17 have backup power from an emergency generator in the power house for critical loads such as condensate pumps and cooking equipment. The emergency backup power is metered separately.

Vault Utility

Lessor Lessor

No

Comments:

Telephone Company

On-site Line Owner

Six T-1 lines are brought to the main telephone/server room located in Building 32. Local telephone service is provided by Frontier Communication with a T-1 line connected to router and long distance provided by AT&T travels via VoIP on the Job Corps Data Center network. The data and VoIP communication networks are routed via underground fiber optic cabling. A central fire alarm control/annunciator panel in Security Building 34 monitors fire alarm panels in Dining Hall Building 13, Warehouse Building 27E, Health Occupations Building 27W, and dormitory Buildings 12, 15, 16, and 17. Other fire alarm panels at the center are monitored by lessor's central fire alarm control/annunciator panel in the power house. Comcast provides cable TV in all dormitory lounges and other recreational spaces at the center. The security system is limited to dormitories only with door alarms for unauthorized ingress/egress detection.

Frontier Communication

Maint. Responsibility

Center Center, Lessor

Door Alarms

4.16/2.4 kV, 3-Phase, 4 Wire

120/208V, 3-Phase, 4 WireUnderground

UndergroundPrimary Service

Secondary Service

Distribution Characteristics

9. Electrical (Communication/Alarm/Security)

7. Electrical (Service)

Yes

Central

VOIP

System Capacity Adequate System Condition

GoodYes

Transformer Maint Resp

Utility

System Capacity Adequate System Condition

Yes Good

Generator

Diesel

8. Electrical (Site Lighting)

Roadways Parking Walkways Building Outdoor Sports

Mounting

Control

Pole Pole Pole Building Sport Light

Photocell, Time Clock Photocell, Time Clock Photocell Photocell Switch

System Ownership Maintenance Responsibility System Capacity Adequate System Condition

Center, Lessor Center, Lessor Yes Good

Comments: The site lighting system, consisting of building-mounted exterior and pole-mounted fixtures, is owned and maintained by the lessor. The site lighting system is controlled by photocells and time clocks.

ATS MTS

Yes No

Number of Deficiencies = 4

Fire Alarm Security

Metering Individual and Groups

Page: 4 Date: 12/10/2014 of 4

ACCESSIBILITY

Yes

Comments:

UnknownYesYes

The site and nine buildings were listed on the National Historical Preservation Registry in December, 2010.

Yes

Nationally Registered Site

Site Eligible for National Register

Located in Historic District

Archaeological Significance

04/01/1999

04/01/1999

Center

Center

Active

Active

Aboveground

Aboveground

Near Building 26

Near Building 57

Yes

Yes

Petroleum - Gasoline

Propane

STORAGE TANKS

TypeStatus Location Owner Fuel Type Capacity (Gallons) Install Date

Earthquake Risk

High Low LowMedium LowIBC Low

LightningEarthquake Def. Authority Flooding Tornado Hurricane Forest

Fire

ID

Reg.

Number of Deficiencies = 1

Number of Deficiencies = 1

Accessible Parking: Accessible Slope:

Yes

Curb Cuts:

Yes

Ramps:

YesYes

Site Accessible Route:

GENERAL SITE CONDITION

Rating X Good Fair Poor

The site is well maintained and in good condition.

HISTORIC PRESERVATION

NATURAL HAZARDS

The site condition is not impacting the functional use of the facilities.

The site condition IS impacting the functional use of the facilities.

The site condition IS SIGNIFICANTLY impacting the functional use of the facilities.

Equip/Veh Fueling

Heating

Purpose

Active Energy Use Reduction Program

Active Water Use Reduction Program

Approximate or Measured Waste Recycled

Use of School Dude or CMMS for Preventative Maintenance

Green Purchasing Policy Practiced

Site Stormwater Absorption Measures in Place

Center has Onsite Renewable Energy (PV or Wind)

Center has a Chartered Green Committee & Roster

Center Uses Green Cleaning Practices

SUSTAINABILITY

Comments: The Center currently uses the Benchmate a Computerized Maintenance Management System (CMMS) for preventive maintenance.

Yes

Yes

NO

NO

Yes

Yes

Yes

Yes

50 %

Building Descriptions and Structures

BUILDING 10 - RECREATION/GYMNASIUM

Building Descriptions

Page: 1 of 104

Building: 0010 - RECREATION/GYMNASIUM

BUILDING ENVELOPE

Foundation RoofBuilding

Concrete Loadbearing Masonry Steel

CMU Masonry

Comments: There is stucco finish on the exterior walls.

Wall Roof None Batt

Metal Units - Metal Frame

AccessibilityFeature

GSF NSF Year Built Use Group Historic Ownership#Floors

Assembly 15,740 11,157 1 Leased 1963 Not Evaluated

Comments: Strobes are not provided in the restrooms.

REAL ESTATE

Access to Building

Ramps

Entrance

2nd Egress

Visual Alarm

Corridor/Aisle

Rooms

Stairs

Elevator

Restrooms

Drinking Fountain

Telephone

Yes

N/A

Yes

Yes

Yes

Yes

Yes

N/A

N/A

Yes

No

N/A

ACCESSIBILITY

Structural Systems1.

Exterior Walls2. Number of Deficiencies = 3

Insulation4.

Exterior Doors5.

Material

Asbestos: Yes

The condition and life expectancy of the roof is based on visual observation during the June 2014 Facility Survey.

Drainage Year Life

Remaining Type Area Served

Single Ply Interior Roof Drains, Scuppers 1996 2 Flat Entire Building

Number of Deficiencies = 1

Comments:

3. Roof

Entire Building

Area Served

Page: 2 of 104

Building: 0010 - RECREATION/GYMNASIUM

INTERIOR FINISH

Carpet Concrete Rubber Terrazzo Vinyl Tile Wood

Ceramic Tile Drywall Plaster

Metal Units - Metal Frame Metal Units - Wood Frame

Wood Units - Wood Frame

VERTICAL CIRCULATION

Metal Ladder

Comments: There is a steel ladder to the roof hatch.

Casement - Wood Frame; Single Glazing; Fixed - Aluminum Frame; Double Glazing;

Sliding - Aluminum Frame; Double Glazing;

Acoustical Tile Exposed Structure Gypsum Board Plaster

Windows6.

Floors1. Asbestos: Yes

Interior Walls2.

3.

Interior Doors4.

Heat Source

Heat Distribution

Piping System

Control System

Fresh Air Intake

Energy Conservation

Measure

Area Served

Four heating and ventilating units serve the gymnasium.

An air handler with hot water coils serves the offices and restrooms.

Heating hot water is provided by two cast iron Burnham series 8B boilers manufactured in 2002.

Comments:

Comments:

Comments:

HVAC

Heat1.

Gas-Fired Hot Water Boiler

Gas-Fired Hot Water Boiler

Gas-Fired Hot Water Boiler

Unit Ventilator

Single Duct

Fan Coil

Two-Pipe

Two-Pipe

Two-Pipe

Electric

Electric

Electric

Mechanical

Natural

Mechanical

None

None

None

Gymnasium

Offices

Recreation Area

Ceilings

Page: 3 of 104

Building: 0010 - RECREATION/GYMNASIUM

Mechanical

Mechanical

Mechanical

Toilet/Shower

Restroom

Kiln Area

One 100-gallon commercial gas water heater provides domestic hot water. The water heater is A. O.

Smith model BTR 197 118 with 199 MBH input, 193 GPH recovery capacity, and manufactured on 5/14/2010.

Comments:

Cast-Iron None Cast-Iron

Electric Water Cooler Hose Bibb Lavatory Shower Urinal Water Closet (Flush Valve)

Gas (Natural)

None None ABC Type Fire Extinguisher

Ventilation Area Served

Copper Copper Gas-Fired None No

Hot Water Cold Water Water Heater Water Treatment HW Storage Tank

Grease InterceptorWaste / Vent Interior Storm

Packaged Direct

Expansion (Air Source)

Window Unit None Electric Natural None Recreation Area

Sprinkler System Stand Pipe System Fire Suppression

PLUMBING

Exhaust Ventilation

Number of Deficiencies = 1

Ventilation2.

System Type

Number of Deficiencies = 1

Air Distribution

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .