DJCC Environmental Survey Report
8 MB Posted
- Solicitation number
- DOL121RB20559
About this file
DOL121RB20559 - Environmental Survey Report (June 7 2011)
Text of this file
TABLE 1A
Building 1A Asbestos Bulk Sample Results Detroit Job Corp Center, Detroit, Michigan
Sample Number 1 Floor Location Material
Category 2 Materials / Items
Estimated Quantity of ACM Material
TEC-01 Unknown No location listed in TTL report SM Spray-on Fireproofing ACM 4 Material not observed by GZA
TEC-02 Unknown TSI Corrugated Straight Pipe Insulation ACM
TEC-03 Unknown TSI Corrugated Straight Pipe Insulation ACM
TEC-04 Unknown TSI White Fibrous Straight Pipe Insulation ACM
TEC-05 Unknown TSI Gray Fibrous Elbow Pipe Insulation ACM
TEC-06 Unknown TSI Gray Fibrous Elbow Pipe Insulation ACM
TEC-07 Unknown No location listed in TTL report MM 9" x 9" Dark Gray, Black and White
Streaked Floor Tile ACM Material not observed by GZA
TEC-08 Unknown No location listed in TTL report MM 9" x 9" Dark Gray, Black and White
Streaked Floor Tile ACM Material not observed by GZA
TEC-09 Unknown No location listed in TTL report MM 9" x 9" Beige and Tan Speckled Floor
Tile NAD 5 NA 6
TEC-10 Unknown No location listed in TTL report MM 9" x 9" Beige and Tan Speckled Floor
Tile
NAD NA
TEC-11 Unknown No location listed in TTL report MM 9" x 9" Putty Streaked Floor Tile ACM Material not observed by GZA
TEC-12 Unknown No location listed in TTL report MM 9" x 9" Coffee Streaked Floor Tile ACM Material not observed by GZA
TEC-13 Unknown No location listed in TTL report MM 9" x 9" Dark Coffee Streaked Floor Tile ACM Material not observed by GZA
TEC-14 Unknown No location listed in TTL report MM 1' x 1' Random Groove Ceiling Tile NAD NA
TEC-15 Unknown No location listed in TTL report SM Ceiling/Wall Plaster NAD NA
TEC-16 Unknown No location listed in TTL report MM 1' x 1' Small Dot Cream Colored Ceiling
Tile
NAD NA
TEC-17 Unknown No location listed in TTL report MM Glue Pods Above 1' x 1' Ceiling Tile NAD NA
TEC-18 Unknown No location listed in TTL report SM Wallboard NAD NA
TEC-19 Unknown No location listed in TTL report MM Carpet Mastic NAD NA
TEC-20 Unknown No location listed in TTL report MM 2' x 4' Random Dot Suspended Ceiling
Tile
NAD NA
TEC-21 Unknown No location listed in TTL report MM 2' x 4' False 2' x 2' Suspended Ceiling
Tile
NAD NA
TEC-22 Unknown No location listed in TTL report MM 12" x12" Pink Floor Tile NAD NA
TEC-23 Unknown No location listed in TTL report MM Mastic Below 12" x 12" Pink Floor Tile NAD NA
TEC-24 Unknown No location listed in TTL report MM Roof Filed Membrane NAD NA
TEC-25 Unknown No location listed in TTL report MM Vent Through Roof Flashing ACM 80 square feet
TEC-26 Unknown No location listed in TTL report MM Wall Base Flashing ACM 1,110 square feet
TEC-27 Unknown No location listed in TTL report MM Pitch Pan Flashing ACM 100 square feet
TEC-28 Unknown No location listed in TTL report MM Fan Base Flashing ACM 100 square feet
TEC-29 Unknown In Walls MM Duct Insulation Mastic ACM 2,450 square feet
TEC-30 Unknown No Location Given in Report TSI Tunnel Roof Insulation NAD NA
TEC-31 Unknown On Tunnel Ceiling SM Tunnel Plaster ACM 2,500 square feet
Analytical Results 3
13,600 linear feet
1,920 each
In walls and tunnels
In walls and tunnels
J:\61000\61718 - Detroit Job Corps Center\Environmental Survey\Survey Report\Environmental Report Table 1.xlsx 1 of 4 5/13/2011
Detroit Job Corp Center, Detroit, Michigan
Sample Number 1 Floor Location Material
Category 2 Materials / Items
Estimated Quantity of ACM Material
Analytical Results 3
TEC-32 Unknown On Tunnel Ceiling TSI Tunnel Insulation ACM 2,500 square feet
TEC-33 Unknown No location listed in TTL report MM 1' x 1' Glued-on SCT (Cream Colored) NAD NA
TEC-34 Unknown No location listed in TTL report MM 9" x 9" Green with Black and White
Streaks Floor Tile ACM 1,725 square feet
TEC-35 Unknown No location listed in TTL report 9" x 9" Green with Black and White
Streaks Floor Tile Mastic ACM 1,725 square feet
TEC-36 Unknown No location listed in TTL report MM Tan Linoleum ACM Material not observed by GZA
TEC-37 Unknown No location listed in TTL report MM Pebble Pattern Linoleum ACM 2,010 square feet
TEC-38 Unknown No location listed in TTL report MM 9" x 9" Cream Floor Tile ACM Material not observed by GZA
TEC-39 Unknown No location listed in TTL report MM 12" x 12" White with Grey Specks Floor
Tile
NAD NA
TEC-40 Unknown No location listed in TTL report MM 12" x 12"White with Dark Gray Streaks
Floor Tile
NAD NA
TEC-41 Unknown No location listed in TTL report MM 9" x 9" Dark Gray with Cream and Black
Streaks Floor Tile ACM Material not observed by GZA
TEC-42 Unknown No location listed in TTL report MM 9" x 9" Tan and Black Floor Tile ACM Material not observed by GZA
TEC-43 Unknown No location listed in TTL report MM 12" x 12" Bluish Gray with White and gray Streaks Floor Tile
NAD NA
TEC-44 Unknown No location listed in TTL report MM 9" x 9" Brownish Red with White and
Dark Brown Specks Floor Tile ACM Material not observed by GZA
TEC-45 Unknown No location listed in TTL report MM Black Mastic Under TEC-34 ACM Material not observed by GZA
TEC-46 Unknown No location listed in TTL report MM Tan Mastic Under TEC-35 NAD NA
TEC-47 Unknown No location listed in TTL report MM Black Mastic Under TEC-38 ACM Material not observed by GZA
TEC-48 Unknown No location listed in TTL report MM Tan Mastic Unser TEC-39 NAD NA
TEC-49 Unknown No location listed in TTL report MM Yellow/Tan Mastic Under TEC-40 NAD NA
TEC-50 Unknown No location listed in TTL report MM Black Mastic Under TEC-41 ACM Material not observed by GZA
TEC-51 Unknown No location listed in TTL report MM Black Mastic Under TEC-42 ACM Material not observed by GZA
TEC-52 Unknown No location listed in TTL report MM Yellow/Tan Mastic Under TEC-43 NAD NA
TEC-53 Unknown No location listed in TTL report MM Black Mastic Under TEC-44 NAD NA
TEC-54 Unknown No location listed in TTL report MM Sprayed-on Fireproofing Insulation ACM Material not observed by GZA
TEC-55 Unknown No location listed in TTL report TSI Pipe Joint Insulation (On Fiberglass
Line)
ACM
Included with pipe joint quantity listed for sample TEC-05
TEC-56 Unknown No location listed in TTL report TSI Incinerator Gasket ACM 700 square feet
TEC-57 Unknown No location listed in TTL report TSI Incinerator Fire Brick NAD NA
42911-1A-02 4th Rm 603A 7 MM Grey Window Caulk NAD NA
42911-1A-03 4th Rm 612F MM Grey Window Caulk NAD NA
42911-1A-20 3rd Rm 413A Lounge MM Grey Window Caulk NAD NA
42911-1A-28 3rd Rm 404F MM Grey Window Caulk NAD NA
42911-1A-49 2nd Rm 203A MM Grey Window Caulk NAD NA
J:\61000\61718 - Detroit Job Corps Center\Environmental Survey\Survey Report\Environmental Report Table 1.xlsx 2 of 4 5/13/2011
Detroit Job Corp Center, Detroit, Michigan
Sample Number 1 Floor Location Material
Category 2 Materials / Items
Estimated Quantity of ACM Material
Analytical Results 3
42911-1A-05 4th Hall H-1 SM Plaster NAD NA
42911-1A-06 4th Hall H-1 SM Plaster NAD NA
42911-1A-37 2nd Rm 201A SM Plaster NAD NA
42911-1A-54 2nd Hall H-9 SM Plaster NAD NA
42911-1A-57 2nd Rm 209A Lounge MM Grey Cove Base NAD NA
42911-1A-58 2nd Rm 209A Lounge MM Grey Cove Base NAD NA
42911-1A-59 2nd Rm 209A Lounge MM Grey Cove Base NAD NA
42911-1A-07 4th Hall H-1 MM 12" x 12" Yellow Floor Tile NAD NA
42911-1A-08 4th Hall H-2 MM 12" x 12" Yellow Floor Tile NAD NA
42911-1A-09 4th Hall H-3 MM 12" x 12" Yellow Floor Tile NAD NA
42911-1A-45 2nd Hall H-7 MM 12" x 12" Yellow Floor Tile NAD NA
42911-1A-50 2nd Hall H-7 MM 12" x 12" Yellow Floor Tile NAD NA
42911-1A-55 2nd Hall H-9 MM 12" x 12" Yellow Floor Tile NAD NA
42911-1A-10 4th Hall H-1 MM 12" x 12" Yellow Floor Tile Mastic NAD NA
42911-1A-11 4th Hall H-2 MM 12" x 12" Yellow Floor Tile Mastic NAD NA
42911-1A-12 4th Hall H-3 MM 12" x 12" Yellow Floor Tile Mastic NAD NA
42911-1A-46 2nd Hall H-7 MM 12" x 12" Yellow Floor Tile Mastic NAD NA
42911-1A-51 2nd Hall H-7 MM 12" x 12" Yellow Floor Tile Mastic NA
42911-1A-56 2nd Hall H-9 MM 12" x 12" Yellow Floor Tile Mastic NAD NA
42911-1A-39 2nd Rm 202A MM 12" x 12" Black with White Flecks Floor
Tile <0.25% Chrysotile NA
42911-1A-40 2nd Rm 202A MM 12" x 12" Black with White Flecks Floor
Tile
NAD NA
42911-1A-41 2nd Rm 202A MM 12" x 12" Black with White Flecks Floor
Tile
NAD NA
42911-1A-42 2nd Rm 202A MM 12" x 12" Black with White Flecks Floor
Tile Mastic
NAD NA
42911-1A-43 2nd Rm 202A MM 12" x 12" Black with White Flecks
Floor Tile Mastic
NAD NA
42911-1A-44 2nd Rm 202A MM 12" x 12" Black with White Flecks Floor
Tile Mastic
NAD NA
42911-1A-22 3rd Hall H-4 MM 12" x 12" Tan Floor Tile NAD NA
42911-1A-24 3rd Hall H-4 MM 12" x 12" Tan Floor Tile NAD NA
42911-1A-26 3rd Hall H-4 MM 12" x 12" Tan Floor Tile NAD NA
42911-1A-33 3rd Hall H-5 MM 12" x 12" Tan Floor Tile <0.25% Chrysotile NA
42911-1A-35 3rd Hall H-6 MM 12" x 12" Tan Floor Tile NAD NA
42911-1A-23 3rd Hall H-4 MM 12" x 12" Tan Floor Tile Mastic NAD NA
Insufficient Material
J:\61000\61718 - Detroit Job Corps Center\Environmental Survey\Survey Report\Environmental Report Table 1.xlsx 3 of 4 5/13/2011
Detroit Job Corp Center, Detroit, Michigan
Sample Number 1 Floor Location Material
Category 2 Materials / Items
Estimated Quantity of ACM Material
Analytical Results 3
42911-1A-25 3rd Hall H-4 MM 12" x 12" Tan Floor Tile Mastic 0.3% Chrysotile
42911-1A-27 3rd Hall H-4 MM 12" x 12" Tan Floor Tile Mastic 1.7% Chrysotile
42911-1A-34 3rd Hall H-5 MM 12" x 12" Tan Floor Tile Mastic 15.9% Chrysotile
42911-1A-36 3rd Hall H-6 MM 12" x 12" Tan Floor Tile Mastic 4.9% Chrysotile
42911-1A-01 4th Rm 614 MM Brown Cove Base NAD NA
42911-1A-13 4th Rm 604 MM Brown Cove Base NAD NA
42911-1A-14 4th Rm 606 MM Brown Cove Base NAD NA
42911-1A-21 3rd Rm 401 Lounge MM Brown Cove Base NAD NA
42911-1A-29 3rd Rm 406 Lounge MM Brown Cove Base NAD NA
42911-1A-04 4th Rm 633A MM Black Cove Base NAD NA
42911-1A-15 4th Rm 611F MM Black Cove Base NAD NA
42911-1A-16 4th Rm 611F Lounge MM Black Cove Base NAD NA
42911-1A-38 2nd Rm 210A SM Drywall/Drywall Compound NAD NA
42911-1A-47 2nd Hall H-7 SM Drywall/Drywall Compound NAD NA
42911-1A-48 2nd Hall H-7 SM Drywall/Drywall Compound NAD NA
42911-1A-52 2nd Hall H-8 SM Drywall/Drywall Compound NAD NA
42911-1A-53 2nd Hall H-9 SM Drywall/Drywall Compound NAD NA
42911-1A-17 4th 4th Floor Mechanical Room TSI Fiber Glass Insulation Jacket NAD NA
42911-1A-18 4th 4th Floor Mechanical Room TSI Fiber Glass Insulation Jacket NAD NA
42911-1A-19 4th 4th Floor Mechanical Room TSI Fiber Glass Insulation Jacket NAD NA
Notes:
2. Materials include the following: TSI = Thermal System Insulation, MM = Miscellaneous Materials, SM = Surfacing Materials
5. NAD = No asbestos detected
7. Rm = room
6. NA = Not applicable. Quantities were not calculated for non-ACM materials.
1. Sample names that begin with "TEC" were collected by Testing Engineers and Consultants, Inc. and reported in the “Re-Inspection of Asbestos-Containing Materials”, TTL Associates, Inc., July 2005 (TTL Report). Sample locations were not listed in this report.
3. Analytical results for samples collected by GZA GeoEnvironmental, Inc. in 2011 provided by EMSL Laboratories in Ann Arbor, Michigan using PLM U.S. EPA Method 600 and PLM-NOB U.S. EPA Method 600/R-93/116.
4. ACM = Asbestos containing material as reported in 2005 TTL Report.
1935 square feet
J:\61000\61718 - Detroit Job Corps Center\Environmental Survey\Survey Report\Environmental Report Table 1.xlsx 4 of 4 5/13/2011
TABLE 1B
Building 1B - Asbestos Bulk Sample Results Detroit Job Corps Center, Detroit, Michigan
Sample Number 1 Floor Location Material
Category 2 Materials / Items
Estimated Quantity of ACM Material
TEC-01 Unknown No location listed in TTL report MM 12" x 12" White, Tan and Gray
Blotched Floor Tile ACM 4 Material not observed by GZA
TEC-02 Unknown No location listed in TTL report MM Bumpy Surfacing Material ACM Material not observed by GZA
TEC-03 Unknown No location listed in TTL report SM Wallboard NAD 5 NA 6
TEC-04 Unknown No location listed in TTL report SM Spray-on Fireproofing NAD NA
TEC-05 Unknown No location listed in TTL report MM 2' x 4' Dot and Squiggle Suspended
Ceiling Tile
NAD NA
TEC-06 Unknown No location listed in TTL report MM Carpet Mastic NAD NA
TEC-07 Unknown No location listed in TTL report MM 2' x 4' Random Dot Suspended Ceiling
Tile
NAD NA
TEC-08 Unknown No location listed in TTL report MM 2' x 4' False 2' x 2' Suspended Ceiling
Tile
NAD NA
TEC-09 Unknown No location listed in TTL report MM Roof Field Membrane NAD NA
TEC-10 Unknown No location listed in TTL report MM Base Flashing NAD NA
TEC-11 Unknown No location listed in TTL report MM Vent Through Roof Flashing ACM 50 square feet
TEC-12 Unknown No location listed in TTL report TSI Pipe Joint Insulation NAD NA
42811-1B-12 3rd Rm 443 7 MM Tan Cove Base NAD NA
42811-1B-14 2nd Rm 247 MM Tan Cove Base NAD NA
42811-1B-15 2nd Rm 259 MM Tan Cove Base NAD NA
42811-1B-33 1st Library MM Tan Cove Base NAD NA
42811-1B-11 3rd Rm 443 MM 12" x 12" Tan Floor Tile and Mastic NAD NA
42811-1B-34 1st Rm 054 MM 12" x 12" Tan Floor Tile and Mastic NAD NA
42811-1B-21 2nd Hall H-13 SM Plaster NAD NA
42811-1B-22 2nd Hall H-13 SM Plaster NAD NA
42811-1B-23 2nd Hall H-13 SM Plaster NAD NA
42811-1B-35 1st Rm 054 MM Maroon Cove Base NAD NA
42811-1B-36 1st Rm 058 MM Maroon Cove Base NAD NA
42811-1B-37 1st Rm 063 MM Maroon Cove Base NAD NA
42811-1B-20 2nd Rm D-7 SM Vinyl Wall Covering 15% Chrysotile
42811-1B-24 2nd Rm D-7 SM Vinyl Wall Covering 20% Chrysotile
42811-1B-25 2nd Rm D-7 SM Vinyl Wall Covering 15% Chrysotile
42811-1B-17 2nd Hall H-13 MM 12" x 12" Purple Floor Tile and Mastic NAD NA
42811-1B-18 2nd Hall H-13 MM 12" x 12" Beige with Gray Fleck Floor
Tile and Mastic
NAD NA
42811-1B-29 1st Stairwell S-1 MM 12" x 12" Beige with Gray Fleck Floor
Tile
NAD NA
42811-1B-30 1st Stairwell S-1 MM 12" x 12" Beige with Gray Fleck Floor
Tile Mastic
NAD NA
Analytical Results 3
12,000 square feet
J:\61000\61718 - Detroit Job Corps Center\Environmental Survey\Survey Report\Environmental Report Table 1.xlsx 1 of 2 5/13/2011
TABLE 1B
Building 1B - Asbestos Bulk Sample Results Detroit Job Corps Center, Detroit, Michigan
Sample Number 1 Floor Location Material
Category 2 Materials / Items
Estimated Quantity of ACM Material
Analytical Results 3
42811-1B-31 1st Stairwell S-1 MM 12" x 12" Beige with Gray Fleck Floor
Tile
NAD NA
42811-1B-32 1st Stairwell S-1 MM 12" x 12" Beige with Gray Fleck Floor
Tile Mastic
NAD NA
42811-1B-26 1st Elevator Mechanical Room SM White Spray-on Fire Proofing 15% Chrysotile
42811-1B-27 1st Elevator Mechanical Room SM White Spray-on Fire Proofing 15% Chrysotile
42811-1B-28 1st Elevator Mechanical Room SM White Spray-on Fire Proofing 10% Chrysotile
42811-1B-01 4th Rm D-2 MM 9" x 9" Brown Floor Tile and Mastic NAD NA
42811-1B-07 3rd Rm D-5 MM 9" x 9" Brown Floor Tile and Mastic 0.4% Chrysotile NA
42811-1B-09 3rd Rm D-4 MM 9" x 9" Brown Floor Tile and Mastic 0.7% Chrysotile NA
42811-1B-02 4th Rm D-2 MM 1' x 1' Groove Lay-in Ceiling Tile NAD NA
42811-1B-08 3rd Rm D-5 MM 1' x 1' Groove Lay-in Ceiling Tile NAD NA
42811-1B-10 3rd Rm D-4 MM 1' x 1' Groove Lay-in Ceiling Tile NAD NA
42811-1B-19 2nd Rm D-8 MM 1' x 1' Groove Lay-in Ceiling Tile NAD NA
42811-1B-04 4th Rm H-5 MM Gray Cove Base NAD NA
42811-1B-05 4th Hall H-5 MM Gray Cove Base NAD NA
42811-1B-06 4th Hall H-5 MM Gray Cove Base NAD NA
42811-1B-03 4th Hall H-5 MM Black Cove Base NAD NA
42811-1B-13 3rd Hall H-8 MM Black Cove Base NAD NA
42811-1B-16 2nd Hall H-10 MM Black Cove Base NAD NA
Notes:
5. NAD = No asbestos detected
7. Rm = room
420 square feet
4. ACM = Asbestos containing material as reported in 2005 TTL Report.
6. NA = Not applicable. Quantities were not calculated for non-ACM materials.
1. Sample names that begin with "TEC" were collected by Testing Engineers and Consultants, Inc. and reported in the “Re-Inspection of Asbestos-Containing Materials”, TTL Associates, Inc., July 2005 (TTL Report). Sample locations were not listed in this report.
2. Materials include the following: TSI = Thermal System Insulation, MM = Miscellaneous Materials, SM = Surfacing Materials
3. Analytical results for samples collected by GZA GeoEnvironmental, Inc. in 2011 provided by EMSL Laboratories in Ann Arbor, Michigan using PLM U.S. EPA Method 600 and PLM-NOB U.S. EPA Method 600/R-93/116.
J:\61000\61718 - Detroit Job Corps Center\Environmental Survey\Survey Report\Environmental Report Table 1.xlsx 2 of 2 5/13/2011
TABLE 1C
Building 1C - Asbestos Bulk Sample Results Detroit Job Corps Center, Detroit, Michigan
Sample Number 1 Floor Location Material
Category 2 Materials / Items
Estimated Quantity of ACM Material
TEC-01 Unknown No location listed in TTL report MM 9" x 9" Light Gray Streaked Floor Tile NAD 4 NA 5
TEC-02 Unknown No location listed in TTL report MM 9" x 9" Slate Gray Marbled Floor Tile NAD NA
TEC-03 Unknown No location listed in TTL report MM 9" x 9" Beige Marbled Floor Tile NAD NA
TEC-04 Unknown No location listed in TTL report MM 9" x 9" Beige Streaked Floor Tile ACM 6 Material not observed by GZA
TEC-05 Unknown No location listed in TTL report MM 9" x 9" Tan Speckled Floor Tile NAD NA
TEC-06 Unknown No location listed in TTL report MM 9" x 9" Black, White Streaked Floor
Tile
NAD NA
TEC-07 Unknown No location listed in TTL report MM 1' x 1' Dot and Groove Glued-on
Ceiling Tile
NAD NA
TEC-08 Unknown No location listed in TTL report MM Clue Pod from TEC-08 NAD NA
TEC-09 Unknown No location listed in TTL report SM Wall Plaster NAD NA
TEC-10 Unknown No location listed in TTL report SM Wall Board NAD NA
TEC-11 Unknown No location listed in TTL report MM Carpet Mastic NAD NA
TEC-12 Unknown No location listed in TTL report MM 9" x 9" White Floor Tile ACM Material not observed by GZA
TEC-13 Unknown No location listed in TTL report MM Black Mastic Under TEC-12 ACM Material not observed by GZA
TEC-14 Unknown No location listed in TTL report MM 2' x 4' Dot and Groove Ceiling Tile NAD NA
TEC-15 Unknown No location listed in TTL report MM Roof Field Membrane NAD NA
TEC-16 Unknown No location listed in TTL report MM Vent Through Roof Flashing ACM 50 square feet
TEC-17 Unknown No location listed in TTL report MM Fan Base Flashing NAD NA
TEC-18 Unknown No location listed in TTL report MM Edge Flashing NAD NA
TEC-19 Unknown No location listed in TTL report MM Wall Base Flashing NAD NA
TEC-20 Unknown No location listed in TTL report TSI Pipe Joint Insulation on Fiberglass NAD NA
TEC-21 Unknown No location listed in TTL report SM Spray-on Fireproofing ACM Material not observed by GZA
42811-1C-01 2nd Rm 2 7 MM 12" x 12" White w/ Gray Fleck Floor
Tile
NAD NA
42811-1C-02 2nd Rm 2 MM 12" x 12" White w/ Gray Fleck Floor
Tile
NAD NA
42811-1C-03 2nd Rm 2 MM 12" x 12" White w/ Gray Fleck Floor
Tile
NAD NA
42811-1C-04 2nd Rm 2 MM 12" x 12" White w/ Gray Fleck Floor
Tile
NAD NA
42811-1C-05 2nd Rm 2 MM 12" x 12" White w/ Gray Fleck Floor
Tile
NAD NA
42811-1C-06 2nd Rm 2 MM 12" x 12" White w/ Gray Fleck Floor
Tile Mastic 0.3% Chrysotile NA
42811-1C-07 2nd Rm 2 MM 12" x 12" White w/ Gray Fleck Floor
Tile Mastic
NAD NA
42811-1C-08 2nd Rm 2 MM 12" x 12" White w/ Gray Fleck Floor
Tile Mastic
NAD NA
42811-1C-09 2nd Rm 2 MM 12" x 12" White w/ Gray Fleck Floor
Tile Mastic 0.7% Chrysotile NA
42811-1C-10 2nd Rm 2 MM 12" x 12" White w/ Gray Fleck Floor
Tile Mastic 0.3% Chrysotile NA
42811-1C-11 2nd Barber Shop MM White and Black Speckled Floor Tile NAD NA
42811-1C-12 2nd Barber Shop MM White and Black Speckled Floor Tile NAD NA
42811-1C-13 2nd Barber Shop MM White and Black Speckled Floor Tile 0.4% Chrysotile NA
42811-1C-14 2nd Barber Shop MM White and Black Speckled Floor Tile
Mastic <0.25% Chrysotile NA
Analytical Results 3
J:\61000\61718 - Detroit Job Corps Center\Environmental Survey\Survey Report\Environmental Report Table 1.xlsx 1 of 2 5/13/2011
TABLE 1C
Building 1C - Asbestos Bulk Sample Results Detroit Job Corps Center, Detroit, Michigan
Sample Number 1 Floor Location Material
Category 2 Materials / Items
Estimated Quantity of ACM Material
Analytical Results 3
42811-1C-15 2nd Barber Shop MM White and Black Speckled Floor Tile
Mastic
NAD NA
42811-1C-16 2nd Barber Shop MM White and Black Speckled Floor Tile
Mastic
NAD NA
42911-1C-17 1st Hall H-1 SM Plaster NAD NA
42911-1C-18 1st Hall H-1 SM Plaster NAD NA
42911-1C-19 1st Hall H-1 SM Plaster NAD NA
42911-1C-20 1st Rm 090 MM Tan Cove Base NAD NA
42911-1C-21 1st Rm 081 MM Tan Cove Base NAD NA
42911-1C-22 1st Rm 101 MM Tan Cove Base NAD NA
42911-1C-23 1st Rm 098 MM Tan Cove Base NAD NA
42911-1C-24 1st Rm 097 MM Tan Cove Base NAD NA
42911-1C-25 1st Rm 087 MM 12" x 12" Tan Floor Tile NAD NA
42911-1C-26 1st Rm 087 MM 12" x 12" Tan Floor Tile NAD NA
42911-1C-27 1st Rm 087 MM 12" x 12" Tan Floor Tile NAD NA
42911-1C-28 1st Rm 087 MM 12" x 12" Tan Floor Tile Mastic 0.4% Chrysotile
42911-1C-29 1st Rm 087 MM 12" x 12" Tan Floor Tile Mastic 0.6% Chrysotile
42911-1C-30 1st Rm 087 MM 12" x 12" Tan Floor Tile Mastic 1.0% Chrysotile
42911-1C-31 1st Hall H-2 MM 12" x 12" Purple Floor Tile NAD NA
42911-1C-32 1st Hall H-2 MM 12" x 12" Purple Floor Tile Mastic 1.7% Chrysotile 970 square feet
42911-1C-33 1st Hall H-3 MM 12" x 12" Purple Floor Tile NAD NA
42911-1C-34 1st Hall H-3 MM 12" x 12" Purple Floor Tile Mastic 2.3% Chrysotile 970 square feet
42911-1C-35 1st Hall H-4 MM 12" x 12" Purple Floor Tile NAD NA
42911-1C-36 1st Hall H-4 MM 12" x 12" Purple Floor Tile Mastic NAD NA
42911-1C-37 1st Hall H-1 MM 12" x 12" Beige with Gray Fleck Floor
Tile
NAD NA
42911-1C-38 1st Hall H-1 MM 12" x 12" Beige with Gray Fleck Floor
Tile
NAD NA
42911-1C-39 1st Hall H-1 MM 12" x 12" Beige with Gray Fleck Floor
Tile
NAD NA
42911-1C-40 1st Hall H-1 MM 12" x 12" Beige with Gray Fleck Floor
Tile Mastic 0.3% Chrysotile NA
42911-1C-41 1st Hall H-1 MM 12" x 12" Beige with Gray Fleck Floor
Tile Mastic 0.5% Chrysotile NA
Notes:
4. NAD = No asbestos detected
7. Rm = room
1. Sample names that begin with "TEC" were collected by Testing Engineers and Consultants, Inc. and reported in the “Re-Inspection of Asbestos-Containing Materials”, TTL Associates, Inc., July 2005 (TTL Report). Sample locations were not listed in this report.
2. Materials include the following: TSI = Thermal System Insulation, MM = Miscellaneous Materials, SM = Surfacing Materials
3. Analytical results for samples collected by GZA GeoEnvironmental, Inc. in 2011 provided by EMSL Laboratories in Ann Arbor, Michigan using PLM U.S. EPA Method 600 and PLM-NOB U.S. EPA Method 600/R-93/116.
6. ACM = Asbestos containing material as reported in 2005 TTL Report.
5. NA = Not applicable. Quantities were not calculated for non-ACM materials.
30 square feet
J:\61000\61718 - Detroit Job Corps Center\Environmental Survey\Survey Report\Environmental Report Table 1.xlsx 2 of 2 5/13/2011
TABLE 1D
Building 1D - Asbestos Bulk Sample Results Detroit Job Corps Center, Detroit, Michigan
Sample Number 1 Floor Location Material
Category 2 Materials / Items
Estimated Quantity of ACM Material
TEC-01 Unknown No location listed in TTL report MM 9" x9" Black, Micro White
Speckled Floor Tile NAD 4 NA 5
TEC-02 Unknown No location listed in TTL report MM 12" x 12" Beige, Brown and White
Streaked Floor Tile
NAD NA
TEC-03 Unknown No location listed in TTL report Sm Wallboard NAD NA
TEC-04 Unknown No location listed in TTL report MM 2' x 2' Small Dot and Groove
Suspended Ceiling Tile
NAD NA
TEC-05 Unknown No location listed in TTL report MM Carpet Mastic NAD NA
TEC-06 Unknown No location listed in TTL report MM 1' x 1' Large Groove Suspended
Ceiling Tile
NAD NA
TEC-07 Unknown No location listed in TTL report SM Ceiling/Wall Plaster NAD NA
TEC-08 Unknown No location listed in TTL report TSI Straight Pipe Insulation (FG Line) NAD NA
TEC-09 Unknown No location listed in TTL report MM 2' x 4' Dot and Groove Suspended
Ceiling Tile
NAD NA
TEC-10 Unknown No location listed in TTL report MM 2' x 4' Pinhole and Groove
Suspended Ceiling Tile
NAD NA
TEC-11 Unknown No location listed in TTL report MM 2' x 2' Multidot Suspended Ceiling
Tile
NAD NA
TEC-12 Unknown No location listed in TTL report MM 1' x 1' Small Groove Suspended
Ceiling Tile
NAD NA
TEC-13 Unknown No location listed in TTL report TSI Straight Pipe Insulation (Paper) ACM 6 Material not observed by GZA
TEC-14 Unknown No location listed in TTL report TSI Pipe Joint Insulation ACM 225 each
TEC-15 Unknown No location listed in TTL report SM Spray-on Fireproofing ACM Material resampled, tested negative
TEC-16 Unknown No location listed in TTL report MM 12" x12" Light Brown Floor Tile NAD NA
TEC-17 Unknown No location listed in TTL report MM Mastic Below 12' x 12' Light
Brown Floor Tile
NAD NA
TEC-18 Unknown No location listed in TTL report MM 2' X 4' False 2' x 2' Suspended
Ceiling Tile
NAD NA
TEC-19 Unknown No location listed in TTL report MM Roof Field Membrane NAD NA
TEC-20 Unknown No location listed in TTL report MM Vent Through Roof Flashing ACM 100 square feet
TEC-21 Unknown No location listed in TTL report MM Base Flashing ACM 880 square feet
TEC-22 Unknown No location listed in TTL report MM Edge Flashing ACM 880 square feet
TEC-23 Unknown No location listed in TTL report MM Pitch Pan Flashing ACM 1,000 square feet
TEC-24 Unknown No location listed in TTL report SM Spray-on Fireproofing NAD NA
TEC-25 Unknown No location listed in TTL report MM Fire Door Insulation (FG) NAD NA
TEC-26 Unknown No location listed in TTL report MM Fire Door Insulation (Paper) NAD NA
TEC-27 Unknown No location listed in TTL report MM Fire Door Insulation (Mag) ACM 20 ea
TEC-28 Unknown No location listed in TTL report MM 9" x 9" Mint Green with Gray and
Cream Streaks Floor Tile ACM Material not observed by GZA
Analytical Results 3
J:\61000\61718 - Detroit Job Corps Center\Environmental Survey\Survey Report\Environmental Report Table 1.xlsx 1 of 5 5/13/2011
Detroit Job Corps Center, Detroit, Michigan
Sample Number 1 Floor Location Material
Category 2 Materials / Items
Estimated Quantity of ACM Material
Analytical Results 3
TEC-29 Unknown No location listed in TTL report MM Mastic Below 9" x 9" Mint Green with Gray and Cream Streaks Floor NAD NA
TEC-30 Unknown No location listed in TTL report MM 9" x 9" Dark Green with White and
Black Streaks Floor Tile
NAD NA
TEC-31 Unknown No location listed in TTL report MM Mastic Under 9" x 9" Dark Green with White and Black Streaks Floor NAD NA
TEC-32 Unknown No location listed in TTL report MM 12" x 12" White with Brown
Streaks Floor Tile
NAD NA
TEC-33 Unknown No location listed in TTL report MM Mastic Under 12" x 12" White with
Brown Streaks Floor Tile
NAD NA
TEC-34 Unknown No location listed in TTL report MM 9" x 9" Beige with Cream and Gray
Streaks Floor Tile
NAD NA
TEC-35 Unknown No location listed in TTL report MM 9" x 9" Beige with Cream and Gray
Streaks Floor Tile Mastic
NAD NA
TEC-36 Unknown No location listed in TTL report MM 9" x 9" Gray with Black Streaks
Floor Tile
NAD NA
TEC-37 Unknown No location listed in TTL report MM Mastic Under 9" x 9" Gray with
Black Streaks Floor Tile
NAD NA
TEC-38 Unknown No location listed in TTL report Found beneath existing floor tile
MM
12" x 12" Black with Cream
Streaks Floor Tile ACM 5,010 square feet
TEC-39 Unknown No location listed in TTL report MM Mastic Under 12" x 12" Black with
Cream Streaks Floor Tile
NAD NA
TEC-40 Unknown No location listed in TTL report MM 9" x 9" Black with Tan Floor
Specks Floor Tile
NAD NA
TEC-41 Unknown No location listed in TTL report MM Mastic Under 9" x 9" Black with
Tan Floor Specks Floor Tile
NAD NA
TEC-42 Unknown No location listed in TTL report MM Gray and Cream Pebble Pattern
Linoleum ACM Material not observed by GZA
TEC-43 Unknown No location listed in TTL report MM Gray and Cream Pebble Pattern
Linoleum Mastic ACM Material not observed by GZA
TEC-44 Unknown No location listed in TTL report MM 9" x 9" Dark Gray with Cream
Specks Floor Tile
NAD NA
TEC-45 Unknown No location listed in TTL report MM Mastic Under 9" x 9" Dark Gray with Cream Specks Floor Tile
NAD NA
TEC-46 Unknown No location listed in TTL report MM 9" x 9" White with Brown Specks
Floor Tile
NAD NA
TEC-47 Unknown No location listed in TTL report MM Mastic Under 9" x 9" White with
Brown Specks Floor Tile
NAD NA
TEC-48 Unknown No location listed in TTL report MM Green Pebble Pattern Linoleum ACM Material not observed by GZA
TEC-49 Unknown No location listed in TTL report MM Green Pebble Pattern Linoleum
Mastic ACM Material not observed by GZA
TEC-50 Unknown No location listed in TTL report MM Gray Mastic Under TEC-01 NAD NA
TEC-51 Unknown No location listed in TTL report MM 9" x 9" Gray with Yellow Specks
Floor Tile
NAD NA
TEC-52 Unknown No location listed in TTL report MM Brown Mastic Under 9" x 9" Gray with Yellow Specks Floor Tile
NAD NA
TEC-53 Unknown No location listed in TTL report MM Brown Mastic Under TEC-02 NAD NA
TEC-54 Unknown No location listed in TTL report MM 9" x 9" Red with Black and White
Streaks Floor Tile ACM Material not observed by GZA
TEC-55 Unknown No location listed in TTL report MM Black Mastic Under 9" x 9" Red with Black and White Streaks Floor NAD NA
TEC-56 Unknown No location listed in TTL report MM 12" x 12" Black with White Streaks
Floor Tile
NAD NA
J:\61000\61718 - Detroit Job Corps Center\Environmental Survey\Survey Report\Environmental Report Table 1.xlsx 2 of 5 5/13/2011
Detroit Job Corps Center, Detroit, Michigan
Sample Number 1 Floor Location Material
Category 2 Materials / Items
Estimated Quantity of ACM Material
Analytical Results 3
TEC-57 Unknown No location listed in TTL report 12" x 12" Black with White Streaks
Floor Tile Mastic
NAD NA
TEC-58 Unknown No location listed in TTL report MM 12" x 12" White with Black Flecks
Floor Tile
NAD NA
TEC-59 Unknown No location listed in TTL report MM Black Mastic Under 12" x 12"
White with Black Flecks Floor Tile
NAD NA
TEC-60 Unknown No location listed in TTL report MM 9" x 9" Cream with Brown Specks
Floor Tile ACM Material not observed by GZA
TEC-61 Unknown No location listed in TTL report MM Brown Mastic Under 9" x 9" Cream with Brown Specks Floor Tile
NAD NA
TEC-62 Unknown No location listed in TTL report SM Wall Covering Material ACM 15,840 square feet
TEC-63 Unknown No location listed in TTL report SM Bumpy Surfacing Material ACM 5,250 square feet
TEC-64 Unknown No location listed in TTL report SM Wall Covering (Linoleum Type) ACM Material included in the quantity listed for sample TEC-62
TEC-65 Unknown No location listed in TTL report MM 9" x 9" White Floor Tile NAD NA
TEC-66 Unknown No location listed in TTL report MM Mastic Under 9" x 9" White Floor
Tile
NAD NA
TEC-67 Unknown No location listed in TTL report MM 9" x 9" Gray Floor Tile ACM Material not observed by GZA
TEC-68 Unknown No location listed in TTL report MM Mastic Under 9" x 9" Gray Floor
Tile
NAD NA
TEC-69 Unknown No location listed in TTL report SM Ceiling Plaster ( Rough) NAD NA
TEC-70 Unknown No location listed in TTL report TSI Duct Insulation NAD NA
42711-1D-01 2nd Rm Career Prep 7 MM 12" x 12" White with Grey Flecks
Floor Tile
NAD NA
42711-1D-02 2nd Rm Career Prep MM 12" x 12" White with Grey Flecks
Floor Tile Mastic
NAD NA
42711-1D-03 2nd Rm 361 MM 12" x 12" White with Grey Flecks
Floor Tile
NAD NA
42711-1D-04 2nd Rm 361 MM 12" x 12" White with Grey Flecks
Floor Tile Mastic 0.3% Chrysotile NA
42711-1D-05 2nd Rm 356 MM 12" x 12" White with Grey Flecks
Floor Tile
NAD NA
42711-1D-06 2nd Rm 356 MM 12" x 12" White with Grey Flecks
Floor Tile Mastic
NA
42711-1D-07 2nd Rm CCP Counseling MM 12" x 12" White with Grey Flecks
Floor Tile
NAD NA
42711-1D-08 2nd Rm CCP Counseling MM 12" x 12" White with Grey Flecks
Floor Tile Mastic
NA
42711-1D-09 2nd Rm CCP 1 MM 12" x 12" White with Grey Flecks
Floor Tile
NAD NA
42711-1D-10 2nd Rm CCP 1 MM 12" x 12" White with Grey Flecks
Floor Tile Mastic 0.3% Chrysotile NA
42711-1D-11 2nd Rm Drivers Education MM 12" x 12" White with Grey Flecks
Floor Tile
NAD NA
42711-1D-12 2nd Rm Drivers Education MM 12" x 12" White with Grey Flecks
Floor Tile Mastic <0.25% Chrysotile NA
42711-1D-13 2nd Rm CCP Counselor MM 12" x 12" White with Grey Flecks
Floor Tile
NAD NA
42711-1D-14 2nd Rm CCP Counselor MM 12" x 12" White with Grey Flecks
Floor Tile Mastic
NA
42711-1D-15 2nd Rm 361 SM Grey Spray-on Fire Proofing NAD NA
Insufficient Material
Insufficient Material
J:\61000\61718 - Detroit Job Corps Center\Environmental Survey\Survey Report\Environmental Report Table 1.xlsx 3 of 5 5/13/2011
Detroit Job Corps Center, Detroit, Michigan
Sample Number 1 Floor Location Material
Category 2 Materials / Items
Estimated Quantity of ACM Material
Analytical Results 3
42711-1D-16 2nd Rm 356 SM Grey Spray-on Fire Proofing NAD NA
42711-1D-17 2nd Rm 356A SM Grey Spray-on Fire Proofing NAD NA
42711-1D-18 2nd Rm 356 SM Plaster <1% Chrysotile NA
42711-1D-19 2nd Hall H-5 SM Plaster <1% Chrysotile NA
42711-1D-20 2nd Rm 365A SM Plaster NAD NA
42711-1D-21 2nd Rm CCP 1 MM Tan Cove Base NAD NA
42711-1D-22 2nd Rm Drivers Education MM Tan Cove Base NAD NA
42711-1D-23 2nd Rm CCP Counselor MM Tan Cove Base NAD NA
42711-1D-24 2nd Hall H-1 MM Maroon Cove Base NAD NA
42711-1D-25 2nd Hall H-2 MM Maroon Cove Base NAD NA
42711-1D-26 2nd Hall H-5 MM Maroon Cove Base NAD NA
42711-1D-27 2nd Hall H-3 MM Maroon Cove Base NAD NA
42711-1D-28 2nd Hall H-4 MM Maroon Cove Base NAD NA
42711-1D-30 2nd Hall H-1 MM 12" x 12" Purple Floor Tile NAD NA
42711-1D-31 2nd Hall H-1 MM 12" x 12" Purple Floor Tile Mastic NAD NA
42711-1D-32 2nd Hall H-2 MM 12" x 12" Purple Floor Tile NAD NA
42711-1D-33 2nd Hall H-2 MM 12" x 12" Purple Floor Tile Mastic NAD NA
42711-1D-34 2nd Hall-H-5 MM 12" x 12" Purple Floor Tile NAD NA
42711-1D-35 2nd Hall H-5 MM 12" x 12" Purple Floor Tile Mastic NAD NA
42711-1D-36 2nd Hall H-3 MM 12" x 12" Purple Floor Tile NAD NA
42711-1D-37 2nd Hall H-3 MM 12" x 12" Purple Floor Tile Mastic 0.3% Chrysotile NA
42711-1D-38 2nd Hall H-4 MM 12" x 12" Purple Floor Tile NAD NA
42711-1D-39 2nd Hall H-4 MM 12" x 12" Purple Floor Tile Mastic 0.7% Chrysotile NA
42711-1D-40 2nd 2nd Floor Mechanical Room MM Vibration Dampener NAD NA
42711-1D-41 2nd 2nd Floor Mechanical Room MM Vibration Dampener NAD NA
42711-1D-42 2nd 2nd Floor Mechanical Room MM Vibration Dampener NAD NA
42711-1D-43 2nd 2nd Floor Mechanical Room TSI Insulation Jacket NAD NA
42711-1D-44 2nd 2nd Floor Mechanical Room TSI Insulation Jacket NAD NA
J:\61000\61718 - Detroit Job Corps Center\Environmental Survey\Survey Report\Environmental Report Table 1.xlsx 4 of 5 5/13/2011
Detroit Job Corps Center, Detroit, Michigan
Sample Number 1 Floor Location Material
Category 2 Materials / Items
Estimated Quantity of ACM Material
Analytical Results 3
42711-1D-45 2nd 2nd Floor Mechanical Room TSI Insulation Jacket NAD NA
42711-1D-46 1st Rm 129 MM 12" x 12" Blue/Green Floor Tile NAD NA
42711-1D-47 1st Rm 129 MM 12" x 12" Blue/Green Floor Tile NAD NA
42711-1D-48 1st Rm 129 MM 12" x 12" Blue/Green Floor Tile NAD NA
42711-1D-49 1st Rm 123 MM 12" x 12" Blue/Green Floor Tile NAD NA
42711-1D-50 1st Rm 123 MM 12" x 12" Blue/Green Floor Tile NAD NA
42711-1D-51 1st Rm 129 MM 12" x 12" Blue/Green Floor Tile
Mastic
NAD NA
42711-1D-52 1st Rm 129 MM 12" x 12" Blue/Green Floor Tile
Mastic
NAD NA
42711-1D-53 1st Rm 129 MM 12" x 12" Blue/Green Floor Tile
Mastic
NAD NA
42711-1D-54 1st Rm 123 MM 12" x 12" Blue/Green Floor Tile
Mastic
NAD NA
42711-1D-55 1st Rm 123 MM 12" x 12" Blue/Green Floor Tile
Mastic
NA
42711-1D-56 1st Rm 301 MM 12" x 12" Yellow Floor Tile NAD NA
42711-1D-57 1st Rm 301 MM 12" x 12" Yellow Floor Tile NAD NA
42711-1D-58 1st Rm 301 MM 12" x 12" Yellow Floor Tile NAD NA
42711-1D-59 1st Rm 301 MM 12" x 12" Yellow Floor Tile NAD NA
42711-1D-60 1st Rm 301 MM 12" x 12" Yellow Floor Tile NAD NA
42711-1D-61 1st Rm 301 MM 12" x 12" Yellow Floor Tile Mastic NA
42711-1D-62 1st Rm 301 MM 12" x 12" Yellow Floor Tile Mastic NAD NA
42711-1D-63 1st Rm 301 MM 12" x 12" Yellow Floor Tile Mastic NA
42711-1D-64 1st Rm 301 MM 12" x 12" Yellow Floor Tile Mastic 0.5% Chrysotile NA
42711-1D-65 1st Rm 301 MM 12" x 12" Yellow Floor Tile Mastic NAD NA
Notes:
4. NAD = No asbestos detected
7. Rm = room
6. ACM = Asbestos containing material as reported in 2005 TTL Report.
5. NA = Not applicable. Quantities were not calculated for non-ACM materials.
3. Analytical results for samples collected by GZA GeoEnvironmental, Inc. in 2011 provided by EMSL Laboratories in Ann Arbor, Michigan using PLM U.S. EPA Method 600 and PLM-NOB U.S. EPA Method 600/R-93/116.
2. Materials include the following: TSI = Thermal System Insulation, MM = Miscellaneous Materials, SM = Surfacing Materials
1. Sample names that begin with "TEC" were collected by Testing Engineers and Consultants, Inc. and reported in the “Re-Inspection of Asbestos-Containing Materials”, TTL Associates, Inc., July 2005 (TTL Report). Sample locations were not listed in this report.
Insufficient Material
Insufficient Material
J:\61000\61718 - Detroit Job Corps Center\Environmental Survey\Survey Report\Environmental Report Table 1.xlsx 5 of 5 5/13/2011
TABLE 1E
Building 1E Upper - Asbestos Bulk Sample Results
Detroit Job Corps Center, Detroit, Michigan
Sample Number 1 Floor Location Material
Category 2 Materials / Items
Estimated Quantity of ACM Material
TEC-01 Unknown No location listed in TTL report MM 12" x 12" White Floor Tile NAD 4 NA 5
TEC-02 Unknown No location listed in TTL report MM 12" x 12" White Floor Tile Mastic NAD NA
TEC-03 Unknown No location listed in TTL report MM 2' x 4' Dot and Groove Suspended
Ceiling Tile
NAD NA
TEC-04 Unknown No location listed in TTL report SM Wall Board NAD NA
TEC-05 Unknown No location listed in TTL report MM 2' x 4' Random Dot Suspended
Ceiling Tile
NAD NA
TEC-06 Unknown No location listed in TTL report MM Roof Field Membrane NAD NA
TEC-07 Unknown No location listed in TTL report MM Vent Through Roof Flashing ACM 6 100 square feet
TEC-08 Unknown No location listed in TTL report MM Fan Base Flashing ACM 50 square feet
TEC-09 Unknown No location listed in TTL report MM Asphalt Shingles NAD NA
TEC-10 Unknown No location listed in TTL report MM Edge Flashing ACM 300 square feet
TEC-11 Unknown No location listed in TTL report MM 12" x 12" Floor Tile - Unknown Color NAD NA
TEC-12 Unknown No location listed in TTL report MM 12" x 12" Floor Tile Mastic NAD NA
TEC-13 Unknown No location listed in TTL report MM 9" x 9" Green Floor Tile with Black
Streaks
NAD NA
TEC-14 Unknown No location listed in TTL report MM 9" x 9" Green Floor Tile with Black
Streaks Mastic
NAD NA
Notes:
4. NAD = No asbestos detected
Analytical Results 3
2. Materials include the following: TSI = Thermal System Insulation, MM = Miscellaneous Materials, SM = Surfacing Materials
5. NA = Not applicable. Quantities were not calculated for non-ACM materials.
6. ACM = Asbestos containing material as reported in 2005 TTL Report.
1. Sample names that begin with "TEC" were collected by Testing Engineers and Consultants, Inc. and reported in the “Re-Inspection of Asbestos-Containing Materials”, TTL Associates, Inc., July 2005 (TTL Report). Sample locations were not listed in this report.
3. Analytical results for samples collected by GZA GeoEnvironmental, Inc. in 2011 provided by EMSL Laboratories in Ann Arbor, Michigan using PLM U.S. EPA Method 600 and PLM-NOB U.S. EPA Method 600/R-93/116.
J:\61000\61718 - Detroit Job Corps Center\Environmental Survey\Survey Report\Environmental Report Table 1.xlsx 1 of 1 5/13/2011
TABLE 1F
Building 1E Lower - Asbestos Bulk Sample Results
Detroit Job Corps Center, Detroit, Michigan
Sample Number 1 Floor Location Material
Category 2 Materials / Items Estimated Quantity of ACM
Material
TEC-01 Unknown No location listed in TTL report TSI Sticky Brown Fibrous Straight Pipe
Insulation ACM 4
TEC-02 Unknown No location listed in TTL report TSI Brown Condensate Straight Pipe
Insulation
ACM
TEC-03 Unknown No location listed in TTL report TSI Yellow Straight Pipe Insulation ACM Material not observed by GZA
TEC-04 Unknown No location listed in TTL report TSI Condensate Tank Insulation ACM Material not observed by GZA
TEC-05 Unknown No location listed in TTL report TSI Pipe Joint Insulation ACM 85 each
TEC-06 Unknown No location listed in TTL report TSI Chiller Line Pipe Joint Insulation ACM Material not observed by GZA
TEC-07 Unknown No location listed in TTL report TSI Boiler Exhaust Flue Insulation ACM 500 square feet
TEC-08 Unknown No location listed in TTL report MM Roof Field Membrane NAD 5 NA 6
TEC-09 Unknown No location listed in TTL report MM Pitch Pan Flashing ACM
TEC-10 Unknown No location listed in TTL report MM Base Flashing ACM
TEC-11 Unknown No location listed in TTL report MM Vent Through Roof Flashing ACM
TEC-12 Unknown No location listed in TTL report MM Edge Flashing ACM
TEC-13 Unknown No location listed in TTL report TSI Boiler Insulation (White Powder) ACM
TEC-14 Unknown No location listed in TTL report TSI Boiler Insulation (Brown Fibrous) ACM
TEC-15 Unknown No location listed in TTL report TSI Boiler Insulation (Brown Metallic) ACM
TEC-16 Unknown No location listed in TTL report TSI Fire Brick (White) NAD NA
TEC-17 Unknown No location listed in TTL report TSI Fire Brick (Orange) NAD NA
No Sample Collected- Assumed
1 Electrical Room TSI Asbestos-Cement Panel ACM 500 square feet
Notes:
5. NAD = No asbestos detected
2. Materials include the following: TSI = Thermal System Insulation, MM = Miscellaneous Materials, SM = Surfacing Materials
3. Analytical results for samples collected by GZA GeoEnvironmental, Inc. in 2011 provided by EMSL Laboratories in Ann Arbor, Michigan using PLM U.S. EPA Method 600 and PLM-NOB U.S. EPA Method 600/R-93/116.
4. ACM = Asbestos containing material as reported in 2005 TTL Report.
6. NA = Not applicable. Quantities were not calculated for non-ACM materials.
Analytical Results 3
6,410 square feet
Quantity included on Table 1E Upper
220 linear feet
1. Sample names that begin with "TEC" were collected by Testing Engineers and Consultants, Inc. and reported in the “Re-Inspection of Asbestos-Containing Materials”, TTL Associates, Inc., July 2005 (TTL Report). Sample locations were not listed in this report.
J:\61000\61718 - Detroit Job Corps Center\Environmental Survey\Survey Report\Environmental Report Table 1.xlsx 1 of 1 5/13/2011
TABLE 1G
Penthouse (Building 1A) - Asbestos Bulk Sample Results
Detroit Job Corps Center, Detroit, Michigan
Sample Number 1 Location Material
Category 2 Materials / Items
Estimated Quantity of ACM Material
TEC-01 No location listed in TTL report MM Roofing Material NAD 3 NA 4
TEC-02 No location listed in TTL report SM Spray-on Fireproofing NAD NA
Notes:
3. NAD = No asbestos detected
Analytical Results
1. Sample names that begin with "TEC" were collected by Testing Engineers and Consultants, Inc. and reported in the “Re-Inspection of Asbestos-Containing Materials”, TTL Associates, Inc., July 2005 (TTL Report). Sample locations were not listed in this report.
2. Materials include the following: TSI = Thermal System Insulation, MM = Miscellaneous Materials, SM = Surfacing Materials
4. NA = Not applicable. Quantities were not calculated for non-ACM materials.
J:\61000\61718 - Detroit Job Corps Center\Environmental Survey\Survey Report\Environmental Report Table 1.xlsx 1 of 1 5/13/2011
TABLE 2
Lead Paint Bulk Sampling Results
Detroit Job Corps Center, Detroit, Michigan
Sample # Building # Floor # Room # Medium Lead Concentrations
% wt.
LBP-01 1D 2nd Hall H-4 Maroon paint on door frame <0.010
LBP-02 1D 2nd Hall H-5 Cream paint on radiator 0.029
LBP-03 1D 2 Hall H-2 Red paint on fire extinguisher box 0.050
LBP-04 1D 2 Rm CCP-3 Peach paint on drywall <0.010
LBP-05 1D 2 Rm CCP-3 Orange paint on drywall <0.010
LBP-06 1D 2 Rm CCP-3 Tan paint on drywall <0.010
LBP-07 1D 2 Rm 365 Salmon paint on drywall <0.010
LBP-08 1D 2 Rm 301 White paint on door frame <0.010
LBP-09 1D 2 2nd Floor Mechanical Room Light blue paint on drywall <0.010
LBP-10 1D 1 Rm 147 Dark blue paint on drywall <0.010
LBP-11 1B 1 Stairwell S-2 Gray paint on drywall <0.010
LBP-12 1A 4 RA Room Green paint on door frame <0.010
LBP-13 1A 4 RA Room White paint on drywall <0.010
LBP-14 1A 3 Rm 421 Brown paint on door 0.130
LBP-15 1A 3 Rm 421 Dark brown paint on door frame 0.220
LBP-16 1A 2 Stairwell S-1 Yellow paint on door frame 0.016
J:\61000\61718 - Detroit Job Corps Center\Environmental Survey\Survey Report\Environmental Report Table 2.xls 1 of 1 5/13/2011
TABLE 3
Hazardous Materials Summary Detroit Job Corps Center, Detroit, Michigan
Location Fluorescent Tubes
(Mercury Containing) Ballasts Leaking Ballasts
Mercury Containing Devices
Refrigerants Mold Transformers
Building 1A 926 354 None observed None observed Drinking Fountains - 4 None observed None observed
Building 1B 920 340 None observed None observed None None observed None observed
Building 1C 347 138 None observed None observed Drinking Fountains - 2 None observed None observed
Building 1D 2050 863 None observed None observed Drinking Fountians - 6 None observed 2nd Floor Mechanical Room - 3 Wet Type
Building 1E 439 59 None observed None observed Window AC Units - 2 None observed Room 284 - 1 Dry Type
Notes:
AC = Air Conditioning
J:\61000\61718 - Detroit Job Corps Center\Environmental Survey\Survey Report\Environmental Report Table 3.xls 1 of 1 5/13/2011
N
S
EW
MICHIGAN
SOURCE:
QUADRANGLE LOCATION
SHEET NO.
GZA GeoEnvironmental, Inc.
Engineers and Scientists
PREPARED BY: PREPARED FOR:
www.gza.com
PROJECT NO.DATE: REVISION NO.
DESIGNED BY:
PROJ MGR:
DRAWN BY:
REVIEWED BY: CHECKED BY:
SCALE:
DETROIT JOB CORPS CENTER
11801 WOODROW WILSON STREET
DETROIT, MICHIGAN 48206
ASBESTOS AND BUILDING HAZARD ASSESSMENT
LOCUS MAP
M.C. Smith Associates and Architectural Group, Inc.
East Grand Rapids, MI 49506
MAY 2011 16.0061718.00
FIGURE
LMN
MAR
JMC
NAM 1" = 2000'
HIGHLAND PARK, MICHIGAN
SITE
SHEET NO.
GZA GeoEnvironmental, Inc.
Engineers and Scientists
PREPARED BY: PREPARED FOR:
www.gza.com
PROJECT NO.DATE: REVISION NO.
DESIGNED BY:
PROJ MGR:
DRAWN BY:
REVIEWED BY: CHECKED BY:
SCALE:
DETROIT JOB CORPS CENTER
11801 WOODROW WILSON STREET
DETROIT, MICHIGAN 48206
ASBESTOS AND BUILDING HAZARD ASSESSMENT
EXISTING SITE PLAN
M.C. Smith Associates and Architectural Group, Inc.
East Grand Rapids, MI 49506
MAY 2011 16.0061718.00
FIGURE
LMN
MAR
JMC
NAM AS SHOWN
N
S
EW
0 20 120 240
APPROXIMATE SCALE IN FEET
NOTE:
SITE LAYOUT TAKEN FROM A DRAWING
ENTITLED "EXISTING SITE PLAN".
ORIGINAL SCALE: 1" = 120'.
FIRST FLOOR
MECH
MECHLOUNGE
STORAGE
STORAGE
RA
STORAGE
LIVING
LOUNGE
LOUNGE
LIVING
LOUNGE INCINERATOR
ROOM
SHEET NO.
GZA GeoEnvironmental, Inc.
Engineers and Scientists
PREPARED BY: PREPARED FOR:
www.gza.com
PROJECT NO.DATE: REVISION NO.
DESIGNED BY:
PROJ MGR:
DRAWN BY:
REVIEWED BY: CHECKED BY:
SCALE:
DETROIT JOB CORPS CENTER
11801 WOODROW WILSON STREET
DETROIT, MICHIGAN 48206
ASBESTOS AND BUILDING HAZARD ASSESSMENT
DORMITORY, BUILDING 1A, FIRST FLOOR
SAMPLE LOCATION PLAN
M.C. Smith Associates and Architectural Group, Inc.
East Grand Rapids, MI 49506
MAY 2011 16.0061718.00
FIGURE
LMN
MAR
JMC
NAM AS SHOWN
N
S
EW
0 20 40 80
SCALE IN FEET
NOTES:
1. LAYOUT TAKEN FROM DRAWING FILE A1035
ORIGINAL.DWG, TAB "A1ST", ENTITLED DETROIT
JOB CORPS CENTER, FIRST FLOOR, DORMITORY
BUILDING 1A. ORIGINAL SCALE: 1" = 40'.
2. NO SAMPLES WERE COLLECTED FROM THE
FIRST FLOOR OF BUILDING 1A.
SECOND FLOOR
5F
5A
4F
4A
6A
6F
7A
7F
S2
H-8
S1
203F 203A 202F 202A 201A
212A 212F 213A 213F 214A
9A
9F
8A
8F
0F
0A
1F
1A
S3
H-7
H-9
LIVING
LIVING
LIVING
RA
INDEPENDENT
LIVING
SPECIALIST
LIVING
STORAGE
LAUNDRY
LIVING
OFFICE
SHEET NO.
GZA GeoEnvironmental, Inc.
Engineers and Scientists
PREPARED BY: PREPARED FOR:
www.gza.com
PROJECT NO.DATE: REVISION NO.
DESIGNED BY:
PROJ MGR:
DRAWN BY:
REVIEWED BY: CHECKED BY:
SCALE:
DETROIT JOB CORPS CENTER
11801 WOODROW WILSON STREET
DETROIT, MICHIGAN 48206
ASBESTOS AND BUILDING HAZARD ASSESSMENT
DORMITORY, BUILDING 1A, SECOND FLOOR
SAMPLE LOCATION PLAN
M.C. Smith Associates and Architectural Group, Inc.
East Grand Rapids, MI 49506
JUNE 2011 16.0061718.00
FIGURE
LMN
MAR
JMC
NAM AS SHOWN
N
S
EW
0 20 40 80
SCALE IN FEET
NOTE:
LAYOUT TAKEN FROM DRAWING FILE A1035
ORIGINAL.DWG, TAB "A2ND", ENTITLED DETROIT JOB
CORPS CENTER, SECOND FLOOR, DORMITORY
BUILDING 1A. ORIGINAL SCALE: 1" = 40'.
LEGEND
ASBESTOS SAMPLE LOCATION
LOCATION WHERE CARPET WAS PULLED DURING
DESTRUCTIVE TESTING
THIRD FLOOR
5F
5A
4F
4A
6A
6F
7A
7F
S2
H-5
S1
403F 403A 402F 402A 401
412A 412F 413A 413F 414
9A
9F
8A
8F
0F
0A
1F
1A
S3
H-4
H-6
RA
OFFIC
E
LAUNDRY
STORAGE
JAN.
RA
STORAGE
LAUNDRY
STORAGE
SHEET NO.
GZA GeoEnvironmental, Inc.
Engineers and Scientists
PREPARED BY: PREPARED FOR:
www.gza.com
PROJECT NO.DATE: REVISION NO.
DESIGNED BY:
PROJ MGR:
DRAWN BY:
REVIEWED BY: CHECKED BY:
SCALE:
DETROIT JOB CORPS CENTER
11801 WOODROW WILSON STREET
DETROIT, MICHIGAN 48206
ASBESTOS AND BUILDING HAZARD ASSESSMENT
DORMITORY, BUILDING 1A, THIRD FLOOR
SAMPLE LOCATION PLAN
M.C. Smith Associates and Architectural Group, Inc.
East Grand Rapids, MI 49506
JUNE 2011 16.0061718.00
FIGURE
LMN
MAR
JMC
NAM AS SHOWN
N
S
EW
0 20 40 80
SCALE IN FEET
NOTE:
LAYOUT TAKEN FROM DRAWING FILE A1035
ORIGINAL.DWG, TAB "A3RD", ENTITLED DETROIT JOB
CORPS CENTER, THIRD FLOOR, DORMITORY
BUILDING 1A. ORIGINAL SCALE: 1" = 40'.
LEGEND
ASBESTOS SAMPLE LOCATION
LEAD-BASED PAINT (LBP) SAMPLE LOCATION
3RD FLOOR
BATHROOM
LOCATION WHERE CARPET WAS PULLED DURING
DESTRUCTIVE TESTING
LOCATION WHERE WALL WAS OPENED
DURING DESTRUCTIVE TESTING
FOURTH FLOOR
5F
5A
4F
4A
6A
6F
7A
7F
S2
H-2
S1
603F 603A 602F 602A 601
612A 612F 613A 613F 614
9A
9F
8A
8F
0F
0A
1F
1A
S4
H-1
H-3
S3
B1
RA JAN.
MECH
MECH
STORAGE
LAUNDRY
STORAGE
LAUNDRY
LOUNGE
SHEET NO.
GZA GeoEnvironmental, Inc.
Engineers and Scientists
PREPARED BY: PREPARED FOR:
www.gza.com
PROJECT NO.DATE: REVISION NO.
DESIGNED BY:
PROJ MGR:
DRAWN BY:
REVIEWED BY: CHECKED BY:
SCALE:
DETROIT JOB CORPS CENTER
11801 WOODROW WILSON STREET
DETROIT, MICHIGAN 48206
ASBESTOS AND BUILDING HAZARD ASSESSMENT
DORMITORY, BUILDING 1A, FOURTH FLOOR
SAMPLE LOCATION PLAN
M.C. Smith Associates and Architectural Group, Inc.
East Grand Rapids, MI 49506
JUNE 2011 16.0061718.00
FIGURE
LMN
MAR
JMC
NAM AS SHOWN
N
S
EW
0 20 40 80
SCALE IN FEET
NOTE:
LAYOUT TAKEN FROM DRAWING FILE A1035
ORIGINAL.DWG, TAB "A4TH", ENTITLED DETROIT JOB
CORPS CENTER, FOURTH FLOOR, DORMITORY
BUILDING 1A. ORIGINAL SCALE: 1" = 40'.
LEGEND
ASBESTOS SAMPLE LOCATION
LEAD-BASED PAINT (LBP) SAMPLE LOCATION
LOCATION WHERE CARPET WAS PULLED DURING
DESTRUCTIVE TESTING
S2 B-1 B-2 B-3
ELEVATOR
MECH
H-9
H-9
H-9
063B
063A 063 063
059 059A
ADMISSION
ADMISSION
STORAGE
S1
FIRST FLOOR
TRAINING/CONFERENCE
LIBRARY OFFICE
FINANCE
DIRECTOR OF
ADMINISTRATION
PURCHASING
HUMAN RESOURCE
DIRECTOR
HUMAN RESOURCE
DEPARTMENT
MAILROOM
STORAGE
SERVER ROOM
KITCHENETTE
WAITING
SHEET NO.
GZA GeoEnvironmental, Inc.
Engineers and Scientists
PREPARED BY: PREPARED FOR:
www.gza.com
PROJECT NO.DATE: REVISION NO.
DESIGNED BY:
PROJ MGR:
DRAWN BY:
REVIEWED BY: CHECKED BY:
SCALE:
DETROIT JOB CORPS CENTER
11801 WOODROW WILSON STREET
DETROIT, MICHIGAN 48206
ASBESTOS AND BUILDING HAZARD ASSESSMENT
ADMINISTRATION/DORMITORY, BUILDING 1B,
FIRST FLOOR - SAMPLE LOCATION PLAN
M.C. Smith Associates and Architectural Group, Inc.
East Grand Rapids, MI 49506
MAY 2011 16.0061718.00
FIGURE
LMN
MAR
JMC
NAM AS SHOWN
N
S
EW
0 10 20 40
SCALE IN FEET
NOTE:
LAYOUT TAKEN FROM DRAWING FILE A1035
ORIGINAL.DWG, TAB "B1ST", ENTITLED DETROIT JOB
COR…
This is the start of the file's text. The full file is on GovTribe.