Detroit Job Corps Center Amendment 2 - 1 Solicitation No. DOL121RB20559 Amendment No. 2

CHANGES TO SPECIFICATION

Revise the specifications sections as outlined below according to the following text in BOLD :

1. Division 01 Section 01 1000 “Summary”

a. Delete subparagraph 1.9.K.3.

2. Division 01 Section 01 3233 “Photographic Documentation”

a. Change paragraph 3.1.D to read as follows:

D. Selective Construction Video Recordings: Record video recording of the following construction activities:

1. Predemolition conditions.

2. Erection of precast concrete elements.

3. Installation of roofing system(s).

4. Demonstration of equipment and training of Owner ’s personnel.

3. Division 01 Section 01 4000 “Quality Control, Testing And Inspection Services”

a. Delete the last sentence in subparagraph 1.9.E.4 .

4. Division 03 Section 03 4103 “Precast Concrete Wall Panels”

a. Add new subparagraph 1.4.F as follows:

F. Finish: Wall panel finish shall comply with PCI Plate #228.

1. Light sandblast.

2. Cement: White.

3. Fine Aggregate: Crushed gray limestone.

4. Coarse Aggregate: 1/2-inch gray limestone.

5. Division 04 Section 04 2000 “Unit Masonry”

a. Delete subparagraph 3.6.C.1.

6. Division 08 Section 08 7100 “Door Hardware”

a. Add new subparagraph 2.3.B.1.f as follows:

f. Pemko Manufacturing Co.; an ASSA ABLOY Group Com pany (PEM).

Detroit Job Corps Center Amendment 2 - 2 Solicitation No. DOL121RB20559

7. Division 08 Section 08 7100 “Door Hardware”

a. Add new subparagraph 2.12.A.1.e as follows:

e. Rixson Specialty Door Controls; an ASSA ABLOY Gr oup company

(RIX).

8. Division 08 Section 08 7100 “Door Hardware”

a. Add new subparagraph 2.13.A.1.e as follows:

e. National Guard Products, Inc. (NGP).

9. Division 08 Section 08 7100 “Door Hardware”

a. Add new subparagraph 2.14.A.1.f as follows:

f. National Guard Products, Inc. (NGP).

10. Division 09 Section 09 3000 “Tiling”

a. At subparagraph 2.2.A.1, change the indicated Basis-of-Design Product from “Stone Peak Ceramics, Inc.; Slate Collection ” to read “Florim USA; Stone Fire Series .”

b. Change subparagraph 2.2.A.6.a.1) to read “Florim USA; Stone Fire Series, “Almond .”

c. Change subparagraph 2.2.A.9.d to read “Hardness: Not less than 6 mohs .”

11. Division 10 Section 10 2600 “Wall Protection”

a. Add new subparagraph 2.2.A.1.d as follows:

d. IPC Door and Wall Protection Systems; Division o f InPro Corporation (IPC).

Detroit Job Corps Center Amendment 2 - 3 Solicitation No. DOL121RB20559

CHANGES TO DRAWINGS

Revise the following drawing sheets as outlined below.

1. Sheet A3.1, Door Schedule Area A, make the following changes:

a. A100.1; change the frame designation to read “E/A3.3”.

b. A100.2; change the frame designation to read “F/A3.3”.

c. A130.1; change door type to “Type VL” with “G5 Glazing”.

2. Sheet A3.2, Door Schedule Area B &C, make the following changes:

a. B100.1; change the frame designation to read “M/A3.3”.

b. B100.2; change the frame designation to read “N/A3.3”.

c. B130.1; change door type to “Type VL” with “G5 Glazing”.

3. Sheet A3.4, Detail 1; change keynote 07 26 00.A2 to 07 27 00.A1 reading “MODIFIED

BITUMINOUS SHEET AIR BARRIER – SEE SPECIFICATIONS.”

4. Sheet A3.4, Detail 3; add keynote 07 27 00.A1 reading “MODIFIED BITUMINOUS SHEET AIR BARRIER – SEE SPECIFICATIONS” to the exterior face of the precast concrete wall panel.

5. Sheet A3.4, Detail 5; change keynote 07 26 00.A2 to 07 27 00.A1 reading “MODIFIED

BITUMINOUS SHEET AIR BARRIER – SEE SPECIFICATIONS.”

6. Sheet A3.4, Detail 7; add keynote 07 27 00.A1 reading “MODIFIED BITUMINOUS SHEET AIR BARRIER – SEE SPECIFICATIONS” to the exterior face of the precast concrete wall panel.

7. Sheet A3.4, Detail 9; add keynote 07 27 00.A1 reading “MODIFIED BITUMINOUS SHEET AIR BARRIER – SEE SPECIFICATIONS” to the exterior face of the concrete masonry unit (CMU) wall.

8. Sheet A6.2, Detail 5; add keynote 07 27 00.A1 reading “MODIFIED BITUMINOUS SHEET AIR BARRIER – SEE SPECIFICATIONS” to the exterior face of the concrete masonry unit (CMU) wall.

9. Sheet A6.3, Detail 6; add keynote 07 27 00.A1 reading “MODIFIED BITUMINOUS SHEET AIR BARRIER – SEE SPECIFICATIONS” to the exterior face of the concrete masonry unit (CMU) wall.

10. Sheet A6.3, Detail 7; add keynote 07 27 00.A1 reading “MODIFIED BITUMINOUS SHEET AIR BARRIER – SEE SPECIFICATIONS” to the exterior face of the concrete masonry unit (CMU) wall.

Detroit Job Corps Center Amendment 2 - 4 Solicitation No. DOL121RB20559

11. Sheets C0.7 and C1.2 change Manhole Rim elevations to be as follows:

MH 1 RIM 640.10

MH 3 RIM 641.50

MH 4 RIM 642.25

MH 5 RIM 641.80

MH 6 RIM 641.80

MH 8 RIM 641.10

For MH reference numbers refer to plan sheet C1.1.

All other Rim and Invert information remain as per the plans.

12. Sheet C 0.8 (clarification).

The Temporary Access Drive as shown on Sheet C0.8 shall be constructed as per the plans and details and shall remain in place at the end of the Contract. Restoration and seeding will be required up to the edge of the temporary access drive. Reconstruction of 18 linear feet of curb and gutter at the north end of the driveway will not be required.