This is a facility planning diagram depicting Lab DI sinks that require removal from the DI Loop within a laboratory facility. The drawing illustrates a detailed floor plan layout with color-coded room designations and piping systems, identifying multiple sample locations and decontamination areas throughout the building.
The document identifies 10 lab sinks (Lab Sink 1 through Lab Sink 10) located in various rooms including BB-145, BB-125, BB-141, BB-142, BB-134, BB-110, BB-110, BD-111, BD-124, and BD-135, each assigned corresponding sign labels (DI #1 through DI #10). Additionally, the diagram shows three decontamination sinks (Decontam Sink 1, 2, and 3) and three scope room sinks (Scope Room Sink 1, 2, and 3) with their respective location designations and sign labels. A red-outlined callout box provides technical guidance indicating that DI loop disconnections must be made in the interstitial space above the ceiling to maintain DI loop integrity, with instructions that disconnected sinks may be left in place or removed as part of project scope. The diagram also identifies rough sink locations, equipment designations, and the DI generation system loop-out and loop-return connections necessary for proper facility operation.
View the file
Other files
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
UP
UP
HJKLMNPQRSTUVWXYAABB
Drawing - 4 , Lab DI sinks
VHAMINFahM Polygon
VHAMINFahM Polygon
VHAMINFahM Line
VHAMINFahM Line
VHAMINFahM Rectangle
VHAMINFahM Text Box DI to Machine
VHAMINFahM Text Box DI to potential Machine
VHAMINFahM Text Box Rough sink location
VHAMINKaediC Cloud
VHAMINKaediC Text Box
SPS
VHAMINKaediC Text Box Lab DI Sinks to remove from the DI Loop
VHAMINKaediC Cloud
VHAMINKaediC Callout
DI #1
VHAMINKaediC Callout
DI #2
VHAMINKaediC Callout
DI #3
VHAMINKaediC Callout
DI #4
VHAMINKaediC Callout
DI #5
VHAMINKaediC Callout
DI #6
VHAMINKaediC Callout
DI #7
VHAMINKaediC Callout
DI #8
VHAMINKaediC Callout
DI #9
VHAMINKaediC Callout
DI #10
VHAMINKaediC Callout
DI #11
VHAMINKaediC Callout
DI #12
VHAMINKaediC Rectangle
VHAMINKaediC Polygon
VHAMINKaediC Polygon
VHAMINKaediC Polygon
VHAMINKaediC Rectangle
VHAMINKaediC Rectangle
VHAMINKaediC Rectangle
VHAMINKaediC Rectangle
VHAMINKaediC Rectangle
VHAMINKaediC Rectangle
VHAMINKaediC Cloud
VHAMINKaediC Cloud
VHAMINKaediC Rectangle
VHAMINKaediC Rectangle
VHAMINKaediC Rectangle
VHAMINKaediC Rectangle
VHAMINKaediC Text Box Disconnect the DI loop to these sinks in the interstitial space and tie main supply line back into together and the return lines back together at each location in the interstitial space so the integrity of the DI loop stays intact. The DI lines to the disconnected sinks can be left as is and not demoed or removed as a part of this project.