This is a technical specifications document for traffic signal systems and street lighting infrastructure prepared by the City of Lake Forest, California, establishing detailed requirements for traffic signal installations, modifications, and related equipment. The specifications cover comprehensive material standards, construction methodologies, and qualified product lists for traffic signal cabinets, controllers, detection systems, pedestrian signals, closed-circuit television systems, emergency vehicle preemption systems, street lighting, and associated infrastructure. The document references California Department of Transportation standards, NEMA specifications, and the California Manual on Uniform Traffic Control Devices as governing standards. Key components specified include NEMA TS-2 Plug-N-Go Type P cabinets with Econolite Cobalt controllers featuring touch screens and EOS systems, video detection using Iteris Vantage Apex technology, fiber optic interconnect systems with Corning cable and splice closures, LED luminaires, ADA-compliant pedestrian push buttons, and IP-CCTV systems mounted on traffic signal poles. The specifications mandate pre-installation configuration and testing of cabinet assemblies at the Agency lab at least 21 working days before field installation, with turn-on inspections scheduled between 9:00 a.m. and 2:00 p.m. on working days excluding Fridays and days preceding legal holidays. All installations must include continuous fiber optic cable with no splices between cabinets, proper conduit depths (42 inches beneath streets, 30 inches below curb and gutter), hand-pulled conductors with specific color-coding requirements, and comprehensive testing documentation including pre- and post-installation OTDR traces.

The specifications establish mandatory use of pre-qualified materials and equipment listed on the Lake Forest Traffic Signal Qualified Products List, with substitution requests requiring Agency approval within 30 days of submittal. Specific approved manufacturers include Econolite for controllers, EDI for flasher units, Corning for optical fiber and splice closures, Iteris for video detection, GTT for Emergency Vehicle Preemption systems, and various approved vendors for signal faces, pedestrian signals, and CCTV equipment. All work must comply with California Administrative Code Title 8, the National Electrical Code, and State Standard Specifications Section 86. The Contractor is responsible for maintaining existing detection systems during construction and must complete repairs to damaged systems within 24 hours, with video detection installation required if damage exceeds 50 percent of existing presence loops. Battery backup systems must be included in service enclosure assemblies using approved models from the QPL. All cabinet wiring diagrams must be approved by the City Engineer before construction begins, and a factory-trained technician employed by the controller manufacturer must be present at equipment turn-on to verify proper operation and complete software configuration as needed.

View the file

Other files

Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PART 7 STREET LIGHTING AND TRAFFIC SIGNAL

SYSTEMS

SECTION 700 – MATERIALS

REVISE as follows:

700-1 GENERAL. MODIFY to ADD the following:

The City maintains a Traffic Signal Qualified Product List (QPL) included in Section 700-6 of the Special Provisions. The Engineer shall not be precluded from sampling and testing products on this list. The manufacturer of the product on the QPL shall furnish the Engineer a Certificate of Compliance in accordance with subsection 4-5 “Certificate of Compliance” of the Special Provisions for each type of material supplied.

Requests for substitutions shall be in accordance with subsection 4-6 “Trade Names or Equals” of the Standard Specifications and the Special Provisions.

700-3.5 Conduits.

700-3.5.4 Rigid Non-Metallic Conduit. DELETE in its entirety and SUBSTITUTE with the following:

Rigid non-Metallic conduit shall conform to the requirements of the UL Standard for Rigid Non-Metallic Conduit, Publication UL651 and UL 651B, and the State Standard Specifications Section 86-2.05A “Type-3”. Rigid non-metallic conduit connections shall be of the solvent weld type. Unless otherwise indicated, the minimum trade size and type of conduit shall be as indicated in the table below:

Size Schedule Usage 4” 80* Signal wiring, interconnect* 4” 40 Signal wiring, interconnect 3” 80* Service wiring, primary pole entry, interconnect between intersections* 3” 40 Service wiring, primary pole entry, interconnect between intersections 2-1/2” 80* DLC cables* 2-1/2” 40 DLC cables

2” 40 Type 1 pole entry, pedestrian push button poles

* Schedule 80 conduit shall be used for all conduit installed beneath roadways, driveways and when installed in foundations.

700-3.7 Pull Boxes. ADD the following:

See City of Lake Forest Standard Plan TS-1 for installation.

Traffic signal wiring and interconnect boxes shall be 18-inch deep, No. 6 size (17 ½-inch x 30 ½-inch lid), per the State Standard Plans plan ES-8A, with a lightweight polymer lid and “TRAFFIC SIGNAL” marking, unless otherwise noted on the plans.

Electrical service boxes shall be No. 5 size (13 ¾-inch x 23 ¼-inch lid), per the State

Standard Plans plan ES-8A, with a lightweight polymer lid and “EDISON” marking.

Communications electrical boxes and primary signal wiring boxes, for storage of wire and cable adjacent to traffic signal cabinets, shall be B40 size (23 7/8-inch x 35 ½–inch lid) with a lightweight polymer lid and “TRAFFIC SIGNAL” marking.

The Contractor shall coordinate with Southern California Edison for location of service handholes and install per their requirements.

ADD:

700-3.10.1 Battery Backup System (BBS). Service enclosure assemblies shall include an Agency approved BBS. The system shall consist of bypass switch, Power Transfer Relay, BBS inverter, and batteries as shown in the City of Lake Forest Traffic Signal Standard Plan TS-4. Approved batteries and required cabling shall be provided with the BBS system. BBS components shall be from a model approved on the Lake Forest Traffic Signal QPL.

700-4.4 High Pressure Sodium Luminaires. DELETE in its entirety and SUBSTITUTE with the following:

High pressure sodium luminaires are not permitted for new or modified installations.

Only LED luminaires are permitted, see the QPL for LED luminaires.11

700-4.7.2 Photoelectric Control Units. DELETE e) and SUBSTITUTE with the following:

e) Housed in the service enclosure.

700-4.7.3 Contactor. DELETE in its entirety and SUBSTITUTE with the following. The contactor shall have contacts rated to switch the specified lighting load. The contact configuration shall be “normally open” unless otherwise specified in the Special Provisions. The contactor shall be the solid-state type. No mercury type contactors will be allowed. The contactor shall have a minimum rating of 30A, per contact, inductive load.

700-5.3 Conductors and Cable.

700-5.3.4 Fiber Optic Cable.

700-5.3.4.1 General. MODIFY to ADD the following:

Optical fiber shall be manufactured by Corning per Agency supplied QPL.

700-5.3.4.3 Construction. DELETE in its entirety and SUBSTITUTE with the following:

All materials furnished, assembled, fabricated or installed under this item shall be new, corrosion resistant and in strict accordance with the details as shown the Lake Forest Traffic Signal Standard Plan TS-2. All fibers in the cables shall be usable fibers and free of surface imperfections and occlusions, in order to meet or exceed all of the optical, mechanical, and environmental requirements contained within.

700-5.3.4.5 Identification. MODIFY to ADD the following:

1. The optical fiber cable outer jacket shall be marked with manufacturer's name, the month and year of manufacture, the words "Optical Cable," telecommunications handset symbol as required by Section 350G of the National Electrical Safety Code (NESC®), fiber count, fiber type, and sequential feet marks.

2. The markings shall be repeated every two (2) feet.

3. The actual length of the cable shall be within ±1% of the length marking.

4. The marking shall be in a contrasting color to the cable jacket.

5. The marking shall be approximately 2mm in height regardless of the cable diameter.

700-5.3.4.6 Quality Control. MODIFY to ADD the following:

The manufacture(s) of supplied optical cable, optical cable assemblies, and hardware shall be TL 9000 and/or ISO 9001 registered. All cabled optical fibers shall be 100% attenuation tested. The attenuation of each fiber shall be provided with each cable reel.

700-5.4 Controllers. ADD:

700-5.4.1.1 Signal Controller Cabinet Assembly. The signal control cabinet assembly shall include the following components:

a) Traffic signal controllers as defined in subsection 700-5.4.4.6 of theseSpecifications12

b) Detection and isolation subsystem as defined in subsection 700-5.4.4.7 of these Specifications

c) Load switch as defined in subsection 700-5.4.4.8 of these Specifications

d) Controller cabinet power supply as defined in subsection 700-5.4.4.9 of these Specifications

e) Malfunction Management Unit as defined in subsection 700-5.4.4.10 of these

Specifications

f) Fiber Interconnect Unit (FIU) as defined in subsection 700-5.4.4.11 of these Specifications

g) Fiber Optic Splice Closure as defined in subsection 700-5.4.4.11 of these Specifications

h) Communications data network as defined in subsection 700-5.4.4.12 of these

Specifications

i) A roll out computer table/drawer shall be mounted at a location designated by the City Representative

j) Inside Auxiliary Control Panel Switches as defined in subsection 700-5.4.4.13 of these Specifications

k) Removable manual control pushbutton with coiled cable

l) Front door LED lighting (downward reflectorized) with door- actuated switches

700-5.4.2 Cabinet Wiring.

Cables. All Controller and MMU cables shall be of sufficient length to access any shelf position. All cables shall be encased in a protective sleeve along their entire free length. Cables shall not obstruct the display or use of any cabinet equipment.

All cabinet wiring shall be color coded as follows:

Purple = Flash color programming Brown = Green Signal Wiring Yellow = Yellow signal wiring Red = Red signal wiring Blue = Controller wiring Gray = DC ground(return), (logic ground) Black = AC+ White = AC - (Neutral) Green= Chassis/Ground

Main-Panel and Wire Terminations. All wires terminated behind the main-panel and other panels shall be soldered. No pressure or solderless connectors shall be used. Printed circuit boards shall not be used on main panels. The main panel shall have a minimum clearance of 4 inches from the cabinet floor.

Flashing Operation. Cabinet shall be wired for NEMA flash. All cabinets shall be wired to flash red for all phases. Flashing display shall alternate between phases 1, 4, 5 and 8, and phases 2, 3, 6 and 7.

Detector Rack and Interface. A minimum of one vehicle loop detector rack and one detector interface panel shall be provided in each cabinet. Each rack shall support up to sixteen (16) channels of loop detection and one (1) BIU. Detector rack shall be labeled for each detector channel used and shall correspond with the cabinet door diagram. Labeling shall be a minimum of an 11-pt. font.

Main Panel Configuration. The main panel shall be fully wired in the following configuration:

a. Sixteen load sockets.

b. Six flash transfer relay sockets.

c. One flasher socket.

d. Wiring for Type 2 Controllers.

e. Wiring for one Type -16 MMU.

Field Terminal Locations. Field terminals shall be located at the bottom of the main panel and angled forward for easy viewing and wiring. Their order shall be left to right beginning with phase one and following the order of the load switches. Field terminals shall be of the barrier type.

700-5.4.3 Cabinet Construction. MODIFY to ADD the following:

The traffic signal controller assembly shall be a NEMA Plug-N-Go TS 2 Type P Cabinet as defined herein.

Interior and exterior cabinet surfaces shall be powder coat finished in White (AMS- STD-37925): Pursuant to Aerospace Material Specification (AMS) AMS-STD-595.

ADD:

Location. The preferred location for cabinet placement shall be per Lake Forest Standard Plan TS-6B, on the far-side corner of the main arterial, in the direction of the primary flow of traffic. The Engineer must approve any variance from the preferred location.

Cabinet Foundation. The foundation shall be constructed per Lake Forest Standard Plan TS-6A.

Cabinet Material. The cabinets shall meet, as a minimum, all applicable sections of the NEMA Standard Publication. Where differences occur, this specification shall govern. The following specification is standard from Econolite and shall be used for inspection purposes:

a) Material shall be 5052-H32 0.125-inch-thick aluminum.

b) The cabinet exterior shall be painted as indicated.

c) The door hinge shall be of the continuous type with a stainless-steel hinge pin.

d) The door handle shall be cast aluminum.

e) All seams shall be sealed with RTV sealant or equivalent material on the interior of the cabinet.

f) Cabinet lock shall be of the Corbin No. 2 type.

g) Each cabinet shall have 4 sets of cabinet wiring diagrams.

h) Each cabinet shall have 1 set of equipment manuals (Controller, MMU, etc.).

i) For cabinets that are installed to replace existing cabinets, existing communications, CCTV, BBS equipment, and alternative detection systems shall be moved to the new cabinet and verified operational on day of “Turn On”.

j) Cabinets shall be constructed to accommodate existing attached items such as existing Type ll service, BBS cabinet, exterior conduit(s), etc. as well as interior items referred to in (i).

Inside Auxiliary Control Panel Switches. The inside door panel shall contain three (3) switches: Auto/Flash; Stop Time; and Controller Power On/Off. Auxiliary door panel switches shall be hard wired only. No printed circuit boards shall be used for the door panel switches.

2-Position Auto/Flash Switch In the Auto position the intersection shall operate normally. When in the Flash position, power shall be maintained to the controller and the intersection shall be placed in flash. The controller shall not be stop timed when in flash. A guard shall be installed to prevent the switch from being shut off accidentally.

3-Position Auto/Off/On Stop-Time Switch When in the Auto position the controller shall be stop timed when the police door AUTO/FLASH switch is in the flash position or MMU flash. If in the Off position the switch will release all stop time from controller. In the On position the switch shall maintain a continuous stop time to the controller.

2-Position Controller Power On/Off Switch This switch shall control the controller’s AC power. A guard shall be installed to prevent the switch from being shut off accidentally.

Shelves. Two (2) aluminum shelves extending completely across the back of the cabinet in the top cabinet area. The rear of each shelf shall be turned upward in order to prevent any shelf mounted equipment from coming in contact with the back wall or electrical panels. The shelves shall not interfere with the lowering or removal of the main panel.

1. The first aluminum shelf shall be the top shelf and extend completely across the back of the cabinet and shall be provided to support detector rack(s) and auxiliary equipment.

2. The second aluminum shelf extending completely across the back of the cabinet shall be provided to support the controller and master (if required), power supply, and the MMU.

Equipment Accessibility. All mounted panels and equipment shall have a minimum tool access clearance of 6”

Ventilation Fan. The cabinet shall be provided with a thermostatically-controlled ventilation fan (adjustable between 80 –150 F) and shall be installed in the top of the cabinet plenum.

Air Filter Assembly. The cabinet Air Filter shall be a one-piece removable, medium efficiency, synthetic, pleated (Econolite Part No. 57389P11) air filter and shall be firmly secured to the air entrance of the cabinet.

Cabinet Light Assembly. The cabinet shall be equipped with an LED light fixture that shall be mounted on the inside of the cabinet near the front edge. This light shall be activated by an on/off switch that is turned on when the cabinet door is opened and turned off when the door is closed.

Lightning Suppression. The cabinet shall be equipped with an HESCO/FLS- HE-300-15, or City-approved equivalent surge arrester.

Convenience Outlet. Two types of outlets shall be supplied, as per the following:

a. The first is a duplex outlet for short-term equipment use and shall be a 120-volt AC, 15 Amp NEMA 5-15 GFCI duplex outlet shall be mounted in the lower right corner of the cabinet facing the inside of the cabinet door and within 6" of the front edge of the opening of the door.

b. The second is two (2) duplex outlets for long-term equipment use and shall be 120 volt AC, 15 Amp NEMA conveniently located and sufficient to provide power to all existing or proposed ancillary equipment. Power shall be supplied from un-switched filtered power.

BIU (Bus Interface Unit). BIU’s shall meet all TS2-1992, Section 8 requirements. In addition, all BIU’s shall provide three (3) separate front panel indicators: Power, Valid Data, and Transmit.

Flasher Unit. All flasher units shall meet NEMA TS-2, Section 6 requirements and shall be EDI Model 810, or City-approved equal.

Cabinet Wiring Diagrams. Cabinet wiring diagrams shall be arranged on three separate sheets in a simplistic way to facilitate the reading of it. The first sheet shall represent everything on the left side of the cabinet, the second everything in the middle of the cabinet including the main panel, and the third sheet everything on the right side of the cabinet. The City Engineer shall approve the final cabinet wiring diagram layout. Cabinet construction shall not begin before approval.

Intersection sketch shall be included on wiring diagrams. All field wire terminations and detector rack assignments shall be labeled on wiring diagrams.

All pages shall have a title block which includes the cabinet wiring diagram identification number, the City, and the intersection name.

Econolite Systems shall arrange to have a signal technician, qualified to work on the controller assembly and employed by the controller manufacturer or his representative, present at the time the equipment is turned on. Technician will have capability of upgrading controller software, if needed, and complete necessary work to provide a fully functioning cabinet.

ADD:

700-5.4.4.5 Contactor. The power distribution assembly shall utilize a solid-state type contactor. No mercury type contactors will be allowed. The contactor shall have a minimum rating of 50A, per contact, inductive load.

ADD:

700-5.4.4.6 Controller Unit. The Lake Forest traffic signal controller unit shall be as specified in the plans or Econolite Cobalt controller with touch screen (Standard). The controller unit shall be from a manufacturer approved on the QPL. The Econolite Cobalt controller shall include EOS System with Ethernet port, data key, FSK Card and SD Card.

A client site license certificate shall be provided with each controller.

All installations shall include a factory produced category 5e network cable to interface the traffic signal controller to the communications network switch. The controller cabinet communication shall be verified with a Master controller. If BBS is used, controller shall allow logging of three (3) alarm inputs as required in the specification for battery back-up system.

ADD:

700-5.4.4.7 Detection and Isolation Subsystem.

Input Files: Lake Forest Type P signal control cabinets shall include eight (8) position detector rack with sixteen (16) channels of detection and six (6) two channel detector amplifiers, and one (1) bus interface unit (BIU), and detector isolations where loops are being used. Each input file shall be a NEMA TS-2 standard from a manufacturer approved on the QPL under the “Type P Cabinets” section. The input file slots shall be allocated and labeled as shown on the Lake Forest Traffic Signal Standard Plan TS-6C.

Detectors and Isolators: Inductive loop detectors shall be Model 222, two channel units. DC isolators shall be Model 242, two channel units. AC isolators shall be Model 252, two channel units. Detectors and isolators shall be from a manufacturer approved on the most recent SQPL under the respective sections or as amended by the QPL.

ADD:

700-5.4.4.8 Load Switch. Output and auxiliary files: Lake Forest Type P signal control cabinets shall include one NEMA TS-2 Standard, Sixteen (16) position load bay and twelve (12) load switches. The load control subsystem shall be fully populated with sixteen (16) Model 200 Switch Packs and all relays. Switch Packs shall be compatible for use with a model 2010 SMU with plus features activated (PDC SSS-86-3 or equivalent). All load control subsystem components shall be from a manufacturer approved on the QPL. The output and auxiliary file slots shall be labeled for phase and function.

ADD:

700-5.4.4.9 Controller Cabinet Power Supply. The main power distribution assembly shall be a NEMA TS-2 Standard. All power distribution subsystem components shall be from a manufacturer approved on the most recent SQPL under the “Model 206L Power Supply Module” sections or as amended by the QPL.

The Power Panel shall house the following equipment:

1. One (1) 40-Amp main breaker to supply power to the main panel, controller, MMU, and cabinet power supply.

2. One (1) 15-Amp auxiliary breaker to supply power to the fan, light, and GFCI outlet.

3. One (1) 50-Amp, 125-VAC radio interference line filter.

4. One (1) normally open, 60-Amp, Crydom Model #HA8475 solid-state relay, or City-approved equivalent.

ADD:

700-5.4.4.10 Malfunction Management Unit. The Malfunction Management Unit shall equip with LCD display (programmed for each specific intersection). Agency approved models are listed on the QPL.

ADD:

700-5.4.4.11 Fiber Optic Interconnect Unit. Cabinet assemblies shall include a Fiber Optic Interconnect Unit (FIU) to provide for termination of fiber optic cable. The FIU shall be assembled from components listed on the QPL, unless otherwise specified in the project plans. The exact quantities of components required shall be defined by the fiber charts provided by the Agency before signal turn-on. The FIU shall interface with the Fiber optic splice closure via a drop cable.

Any below ground fiber optic splices or fiber optic splices exposed to the elements shall be contained in a waterproof, rodent proof, re-enterable fiber optic splice closure designed for use on optical fiber cables in a cable vault environment where total and continuous submersion in water may be expected.

Splice closures shall be complete with outer and inner closures, splice organizer trays, brackets, plugs, clips, cable ties, seals and sealant, and a dry encapsulate and shall conform to the following Special Provisions.

1. The fiber optic splice closure be designed for a temperature range of -40° C. to +70° C.

2. The splice closure shall be suitable for either a direct burial or pull box/vault application.

3. The size of the closure shall allow all the fibers of the largest fiber optic cable to be spliced to a second cable of the same size. The closure shall be not more than 22 inches in length and diameter of either 4 inch to 6 inch. The closures shall be designed for both horizontal and butt splicing.

4. All materials in the closures shall be non-reactive and shall not support galvanic cell action. The outer closure shall be compatible with the other closure components, the inner closure, splice trays, and cables.

5. The outer closure shall protect the splices from mechanical damage; shall provide strain relief for the cable and shall be resistant to salt corrosion. The outer closure shall be waterproof, and re-enterable. The outer-closure shall be flash-tested at 100 kPa.

6. The inner closure shall be of metallic construction. The inner closure shall be compatible with the outer closure and the splice trays and shall allow access to and removal of individual splice trays.

7. The splice trays shall be compatible with the inner-closure and shall be constructed of rigid plastic or metal.

The splice closure shall be assembled from components listed on the QPL, unless otherwise specified in the project plans. The exact quantities of components required shall be defined by the fiber charts provided by the Agency before signal turn on.

ADD:

700-5.4.4.12 Communication Data Network. Agency approved models are listed on the QPL herein.

An additional switch that is compatible with twisted pairs shall be installed as needed to bridge the existing twisted pairs to fiber communication network.

700-5.5 Traffic Signal Faces and Fittings. MODIFY to ADD the following:

Traffic signal faces and fittings shall conform to the latest State Standard:

a) State Standard ES-4D

b) State Standard Plan RSP ES-4E

700-5.5.11 Circular Light Emitting Diode (LED) Signal Modules. MODIFY to ADD the following:

Agency approved models are listed on the QPL.

700-5.6.2.5 Housing. DELETE in its entirety and SUBSTITUTE with the following:

Housing shall conform to the latest State Standard:

a) State Standard Plan ES-4B

b) Pedestrian heads shall be clamshell side-mount Types SP-1-T, SP-2-T or top- mount TP-1-T

700-5.6.6 Pedestrian Signal Sections. DELETE in its entirety and SUBSTITUTE with the following:

Agency approved models are listed on the QPL.

700-5.8 Detection Systems.

700-5.8.2 Inductive Loop Detectors. MODIFY to ADD the following:

Inductive loop detection shall be utilized only for advanced detection on all new traffic signals. Modifications involving replacement of less than 50% of existing presence (limit line) detection loops may retain inductive loop detectors unless otherwise shown on the plans.

700-5.8.2.2 Sensor Units. MODIFY to ADD the following:

a) Type-P cabinet applications shall use Model 262-FC sensor units.

700-5.8.2.3 Conductors. MODIFY to ADD the following:

Lake Forest Inductive loop installations shall use only Type 2 loop wire and Type B lead-in cable (DLC).

700-5.8.4 Video Detection System.

700-5.8.4.1 General. A complete Video Detection System, Iteris Vantage Apex, shall be supplied by Contractor.

700-5.8.4.2 Equipment Specifications The following are considered minimum video detection system Specifications:

700-5.8.4.2.1 System - General Temperature: -35 F to +165 F (-34 C to + 74 C) Humidity: 0% to 95% non-condensing Vibration: 0.5G, 3 axes, 5-30Hz Shock: 10G in all 3 axes Ingress protection: IP67 Regulatory: NEMA TS-2

FCC Part15, Class A Warranty: 3 Years limited warranty

700-5.8.4.2.2 Sensor Head – General Connections: Terminal Block Communications: Ethernet over Power line Power: Voltage – 110VAC

Consumption: Camera Only – 15W (Max) Dimensions (Excluding Mounting Bracket): Camera only – 16” (406mm) D x 6.25" (159mm) W x 7” (178mm) H

Hybrid – Physical 17” (432mm) D x 15” (381mm) W x 14” (356mm) H Weight: Camera Only – 5lbs (2.3kg)

Hybrid – 10lbs (4.55kg)

700-5.8.4.2.3 Sensor Head – Camera Imager: 1080P 30FPS

1 Lux Minimum Illumination 3D-DNR Noise Reduction

Lens: Lens 12x Optical Zoom Focal Length 5.4” tele to 50.7” wide Dynamic Range > 100dB

Heater: Indium Tin Oxide

700-5.8.4.2.4 Sensor Head – Radar Frequency: 24GHz (K-Band) Accuracy: Speed 0 to 150mph +1mph (0 to 240kph +1.5kph) Tracked Objects: Up to 64

700-5.8.4.2.5 Cabinet Interface Configuration: Up to 4 sensors Communication: Ethernet

USB x4

SDLC

EMBUS

Cabinet Interface (CI) Dimensions: 10” (254mm) D x 4” (101.6mm) W x 10” (254mm) H Power Injector (PI) Dimensions: 10” (254mm) D x 4” (101.6mm) W x 10” (254mm) H

700-5.8.4.2.6 Installation The Contractor shall install the video detection system assembly per manufacturer’s installation requirements.

700-5.8.4.2.7 System Components. Agency approved models are listed on the QPL.

700-5.9 Pedestrian Push Button Assemblies. MODIFY to ADD the following:

Note: Traffic signal modifications shall match installed equipment by make and model.

If the system cannot be matched, the entire system shall be replaced.

All signalized intersections shall have ADA compliant pedestrian and bicycle push buttons as specified below:

a) PPB: New or modified Pedestrian Push Buttons (PPB) shall be ADA compliant Accessible Pedestrian Signals (APS). The sign plates shall be per California MUTCD sign specifications with the full street name in Braille.

b) BPB: New or modified Bicycle Push Buttons (BPB) shall be ADA compliant, non-vibratory, Type B. The sign plates shall be with directional arrow and per California MUTCD sign specifications.

c) Special: When applicable, provide special height push buttons for equestrian trail street crossings.

d) ADA requirements: The pedestrian push button assembly shall be mounted such that the center of the PPB cap is located per ADA regulations or 42-inches from the ground. Bicycle push buttons, and any other non-vibratory buttons, shall have a 2-inch diameter, stainless steel, ADA compliant push button caps.

Agency approved models are listed on the QPL.

ADD:

700-5.10 Closed Circuit Television (CCTV). The CCTV system shall consist of camera/pan-tilt assembly, mounting, cables, conductors and wires, control software and video management system licensing.

700-5.10.1 Mounting. The Contractor shall mount the integrated camera/position unit on existing traffic signal pole as shown on plans and per manufacturer’s recommendation. The Contractor shall verify the mounting requirements of the integrated camera/position unit, and the suitability of the approach depicted in these plans. The Contractor may request approval for alternate mounting details by submitting a shop drawing signed by a registered Engineer.

700-5.10.2 Video Cable. The Contractor shall furnish and install manufacturer recommended Outdoor CAT-6 Ethernet cable with IP66-rated connectors and incidental hardware from the camera to an Ethernet switch in the cabinet to establish circuit continuity. The cable shall be installed without damaging the conductors, dielectric or jacket. The cable assembly shall not be kinked or bent tighter than the Manufacturer's recommended bending radius.

700-5.10.3 Testing. The Contractor shall test and document the installation and operation of all material, equipment, cables and connectors for continuity, shorts or grounds. The Contractor shall also carry out system integration testing to ensure that the video interface and camera interconnect wiring performs to the specified standards when used in operation with all other devices installed under the contract.

700-5.10.4 Warranty.

The Contractor shall provide a warranty for all equipment installed or modified under these projects for the extended warranty period provided by the manufacturer. The warranty shall be 12 months from the time the Agency accepts the Project. The warranty on all parts and equipment used on these projects shall be provided by the manufacturer or agent of the equipment. The Contractor shall provide, at no cost to the Agency, all labor, materials, testing, and equipment required restoring the system to its fully operational condition. Following this warranty period, the Contractor shall assign to the Agency the balance of the manufacturer’s warrantees or guarantees on all electrical and mechanical equipment of the system.

Agency approved IP-CCTV equipment is listed on the QPL.

ADD:

700-5.11 REFLECTORIZED STREET NAME SIGNS (RSNS).

All sign layouts shall be the contractor’s responsibility and shall be in accordance with the City’s and manufacturer’s specifications. All signs shall be made in accordance with layout drawings furnished by the City and these Special Provisions. All sign layouts must be approved by the City prior to final production.

700-5.11.1 GENERAL. All items shall be new. The materials and workmanship shall be the best quality for the purpose. The contractor shall replace any sign delivered under this contract which does not conform to these specifications at no cost to the City.

700-5.11.2 DETAILED REQUIREMENTS

1. Base Metal:

The base metal substrate shall be new sheet aluminum alloy 3003-H14 or 5052- H32.

The thickness of the aluminum shall be 0.05” (1 mm). The material shall be subject to inspection prior to degreasing and chromate conversion coating operations. Alloy and temper designations shall be verified in mill test certifications.

All sign panel edges shall be shear-trimmed or roll-slit to produce neat edges and square corners. Sign panel edges shall be straight within 1/32” (1 mm) form the straight plane. Edge delaminating or incomplete coverage of the base metal substrate up to and coincident with the cut edge of the sign panel shall be sufficient basis for rejection of the entire sign panel.

All treatment tanks and/or spray-applied systems must be performed on the contractor premises, to ensure proper adhesion of reflective sheeting materials. All treatment tanks or spray-applied systems shall be charged with fresh chemicals at least once a year. If pretreatment is performed by immersion methods, the tanks must be sufficient size to accommodate the complete panel. Titration equipment shall be available for the inspectors to check the solutions strengths. The cleaned and coated base metal shall be handled only by a mechanical device or by operators wearing clean cotton or rubber gloves. After cleaning and coating operations, the panels shall be protected at all times from contact or exposure to grease, oils, dust or other contaminates.

The front and back surfaces of the aluminum base metal shall be cleaned, deoxidized, and coated with a light tightly adherent chromate conversion coating free of any powdery residue. The base metal pretreatment process shall be in conformance with Section 5, “Recommended Processing methods” of ASTM Designation B-449. The coating weight shall be 30-100 mg/sq.ft. (285-950 mg/sq.m.), A class 1 coating.

2. Sign Message and Reflectorized Material:

Sign panels with identical legends shall be displayed on both sides of the sign frame unless otherwise indicated.

Letter size, style, spacing, arrows, and figures shall conform to the current standards established by Caltrans and the CA MUTCD.

a. The legends or street name shall be 8” (200 mm) upper case and 6” (150 mm) lower case. Series C shall beused.

b. The City of Lake Forest black and white logo shall be a minimum of 12” diameter.

c. 1” (27 mm) border.

d. Message layout shall be per attached drawing within these specifications. Side margins and spacing may be compressed when necessary to stay within signlength.

3M Diamond Grade DG3 Series 4090 or equivalent shall be used on both fore and background with anti-graffiti overlay that has UV inhibitors. The standard color shall be white legends, letters, borders, etc., on a blue background. No cut out legends, letters or border shall be used.

Signs shall have graffiti coating or film (such as 3M 1160 Overlay) with UV inhibitors as recommended by the manufacturer of the reflective material. Neither the color nor the reflective intensity of the finished sign panel shall be significantly diminished by the use of graffiti remover when used in a manner approved by Caltrans and the sheeting manufacturer.

3. Sign Frame & PanelConstruction:

The width or the sign shall be 18” (450 mm). Length to be determined by the text and shall not be less than 60” (1200 mm) or more than 96” (2400 mm).

a. Frames:

The frame shall be aluminum channel extrusion, 1.25” x 1.25” x .125” (35 x 35 x 3 mm) wall thickness. Alloy 6063-T5. All joints of the aluminum channel shall be welded with an inert gas shielded-arc welding process using 4043 electrode filler wire in accordance with good shop practice. The width of the filler wire shall be equal to the wall thickness of the channel being welded.

The top of the frame will have two 2” x 2” x .250” (53 x 53 x 6 mm) wall thickness channel members welded and fastened to the frame with stainless steel bolt, washer, lock nuts and cotter pins. The adjustable swing assembly will be attached to thesemembers.

b. Assembly:

A sign panel shall be fastened to both sides of the channel frame to make a double-faced unit. Each sign panel must be a continuous sheet, no vertical or horizontal splices to make up one panel.

The sign panels shall be affixed to the frame with 3/16” (5 mm) diameter blind pop rivets, alloy 5052, or a type approved by the City.

They must be aluminum approved. The exposed face of the rivet shall be of similar shade and compatible with face color of the finished sign.

The rivets shall be placed through the face of the sign with the wall of the channel placed against the back of the sign panel. Rivets shall be placed no closer than ½” (13 mm) from the edge of the sign panel and a maximum of 8” (200 mm) apart from one another. All rivets must penetrate the web of the channel frame for proper grip strength between sign panel and frame.

The swing hinge is attached to the 2” x 2” (53 x 53 mm) channel member with a ¼” (7 mm) stainless steel bolt and bronze bushing, and then secured with any lock nut.

4. Mounting Assemblies:

The top of the sign frame shall have two free swinging mounting brackets. They shall be of all aluminum, bronze, and stainless-steel parts. The 5” (125 mm) long stainless-steel bolt for fine adjustments shall have nuts and lock washers, or self-locking nuts and cotter key. Dampening springs are required. The bracket assembly shall permit the sign to swing perpendicular to the supporthardware.

The aluminum mounting brackets shall be adjustable MD Solutions Inc. Oscillating Mast Arm Bracket-Adj or approved equivalent (for example, ZAP Manufacturing Bracket Kit, Hawkins Adjustable Bracket Kit).

When installation of the sign to the mast arm is complete, the sign should swing freely 90 degrees in both directions when moved by the installer.

5. Finish:

The finished sign shall be flat within a ratio of 0.40” (10 mm) per linear foot when measured across the plane of each panel from opposite corners or at any location on the panel. All finished signs shall have a smooth flat surface without defects or objectionable marks of any kind on either the front or the back faces. All letters and designs shall be clearly cut and sharply defined.

The appearance of the sign face shall be uniform throughout and shall be free of wrinkles, gel, hard spots, streaks, extrusion marks, air bubbles or blemishes that may impair the serviceability, detract from the general appearance or color-matching of the sign when viewed from a distance of twenty-five (25) feet (7.5 m).

The finished sign shall be clean and free from all burns, sharp edges, loose rivets and aluminum marks.

Signs with any defects or damage that affect their appearance and serviceability will not be acceptable. All metal parts shall be fabricated in a uniform and quality workmanlike manner with all sign surfaces and edges free of defects. No repairs shall be made to the face sheet without the approval of the City inspectors.

ADD the following:

700-5.11.1 Payment

The payment for reflectorized street name signs (RSNS) shall include, but not limited to, all hardware components, mounting components, signage (double-sided), brackets, updating City’s GIS asset management program, and Work to remove, furnish and install reflectorized street name signs per the Contract Documents, unless otherwise noted, and shall be included in the various bid items to “Remove, Furnish and Install Reflectorized Street Name Signs…”.

Contractor shall review the list of street names at signalized intersections and any additional reflectorized street name signs shall be paid per the unit price in the bid.

Agency approved models are listed on the QPL.

ADD:

700-5.12 Emergency Vehicle Preemption (EVP).

700-5.12.1 General. Emergency Vehicle Preemption (EVP) shall include a multimode priority control system shall operate in a manner that allows Infrared, and GPS/Radio priority control technologies to interoperate and activate one another in a consistent manner. The priority control system shall consist of a matched system of vehicle equipment and intersection equipment capable of employing both data-encoded radio communications to identify the presence of designated priority vehicles, as well as data-encoded infrared signaling communications. In priority vehicle mode, the data-encoded communication shall request the traffic signal controller to advance to and/or hold a desired traffic signal display selected from phases normally available. A record of system usage by agency identification number, vehicle classification and vehicle identification number shall be created. The system software shall support call history analysis and reporting across any subset of intersections and/or vehicles independent of activation method. System software shall also support both onsite and remote programming and monitoring of the priority control system.

Agency approved EVP model is listed on the QPL.

700-5.12.2 Components. Agency approved models are listed on the QPL.

700-5.12.3 Warranty. At time of installation, the manufacturer shall warrant the system has been properly installed and is ready for operation. All component parts of the system shall be warranted to be free from workmanship and/or material defects during the first five (5) years from the date of shipment from the manufacturer. The system shall include an additional five-year maintenance coverage plan, providing repair or replacement at a fixed deductible charge to the Agency, for a total of ten (10) years of product coverage.

ADD:

700-5.13 Lighted Crosswalks. Agency approved models are listed on the QPL.

All signs and Rectangular Rapid Flashing Beacons (RRFB) units shall comply with current CA MUTCD requirements.

Lighted crosswalk systems shall provide an audible message when the crosswalk system is activated.

The system shall use ADA compliant push buttons, installed as defined in 700-5.9 “Push Button Assemblies” of these Specifications.

Conduits and pull boxes shall conform to 700-3.5 “Conduit” and 700-3.7 “Pull Boxes” of the Special Provisions.

700-6 LAKE FOREST TRAFFIC SIGNAL QUALIFIED PRODUCTS LIST.18

700-6.1 General. Specific models listed on this Qualified Products List (QPL) are approved by the Agency. Equivalency requests for substitute products shall require submittal of specifications and/or samples, as deemed necessary by the Agency, to determine interchangeability, interoperability, and/or compatibility with existing hardware and equipment. Submittals shall be required before use or installation of any material not specifically listed or defined in the Special Provisions. Materials not specifically listed in the QPL or Special Provisions by make and/or model shall comply with the characteristics defined in the Special Provisions or referenced base specifications.

Equipment equivalency submittals shall be coordinated with the City of Lake Forest Traffic Engineering Division. Such submittals will be reviewed for actual equivalency within 30 days of receipt and approved or declined by the Engineer. Submittal for equivalency shall not guarantee acceptance. Only accepted equipment, as specified herein, shall be allowable for field installation. Approval of equivalency shall be conveyed to the submitter through the Agency Representative in a written memo from the Engineer modifying the specifications herein.

700-6.2 Reference Specifications. Except as modified herein and on the Plans, Specifications, and Special Provisions all components shall conform, where applicable, to the following:

a) State of California Department of Transportation, Qualified Products Lists (SQPL)

b) State of California Department of Transportation, Transportation Electrical Equipment Specifications (TEES)

c) The CA MUTCD

700-6.3 Pre-Qualified Materials and Equipment. Materials and equipment listed in Table 700-6(A) have been pre-qualified for use in the City of Lake Forest. Where no specific make is specified, or to determine the standards for equivalency, refer to the Lake Forest Special Provisions sections listed in the reference column. QPL is the standard at all traffic signal infrastructure, Approved equal products shall be subject to Section 4 in the Greenbook.

Table 700-6(A) Pre-Qualified Materials and Equipment

Material Type Make Model Reference

Standards and Arms: 700-3.3

Conduit: 700-3.5

Pull Boxes: 700-3.7

#5 Box Oldcastle/Christy N30 Electrical Box

BES C30 Electrical Box

#5 Lid Oldcastle/Christy FL 30T

BES PL30T

#6 Box Oldcastle/Christy N36 Electrical Box

BES C36 Electrical Box

#6 Lid Oldcastle/Christy FL36T

BES PL36T

B40/C40 Box Oldcastle/Christy N40 Electrical Box

BES C40 Electrical Box

B40/C40 Lid Oldcastle/Christy SYN2436T

BES PL40T

Electrical Service for Type-P Cabinet: 700-3.10

Left Utility Entrance

Myers Power Products B.M. No. 518606E

Right Utility Entrance

Myers Power Products B.M. No. 518642E

Side Mount BBS Cabinet: 700-3.10.2 Clary CBS-127

Battery Backup System: 700-3.10.2

Clary SP 1250LX

Luminaires: 700-4.4

LumenSafe Navion

Conductors and Wiring: 700-5.3

Interconnect Cable: 700-5.3.3

72-Fiber SMFO Corning 072EU4-T4701D20

12-Fiber SMFO Corning 012EU4-T4701D20

Traffic Signal Cabinet Assembly: 700-5.4

NEMA TS-2 Econolite Plug-N-Go Type 2

Controller Unit and Firmware: 700- 5.4.4.6

Cobalt Econolite EOS Firmware Version (latest)

Input Files and Detector Units: NEMA TS-2 700- 5.4.4.7

Output Files: NEMA TS-2 700- 5.4.4.8

Load Switch Pack: 700- 5.4.4.8

PDC SSS-86-3

Malfunction Management Unit: 700- 5.4.4.10EDI MMU-16LE(ip)

Fiber Optic Splice Closure: 700- 5.4.4.4.11Splice Closure Corning SCF-6C22-01

Splice Tray SCF-ST-099

Fiber Optic Interconnect Unit: 700- 5.4.4.11Term Housing Corning CCH-02U

MM Coupler Panel

CCH-CP12-15T

SM Coupler Panel

CCH-CP12-19T

Fan-Out Kit FAN-BT25-06

MM ST

Connector

95-000-51

SM ST

Connector

95-200-51

Communication Data Network: 700- 5.4.4.12Local Cabinet

Switch Actelis ML 680 DF with two (2) SFPs

(1Gbps) Local Cabinet

Switch at Comm Crossings

ML5114D with four (4) SFPs

Comm HUB Switch

Cisco IE-9320-22S2C4X-A with 4 1/10G SFP ports fully populated

Power Supply PWR-IE170W-PC-AC=

TMC

Switch

Extreme Networks 5520-24T with all SFP ports fully populated

Vehicle and Pedestrian Signal Faces: 700-5.5

12” Red Ball GE Lighting DR6-RTFB-VLA

Dialight 433-1210-003XL

Leotek TSL-12R-LX-IL6-A1

12” Amber Ball GE Lighting DR6-YTFB-1V7LAA-VLA

Dialight 433-3230-901XL

Leotek TSL-12Y-LX-IL6-A1

12” Green Ball GE Lighting DR6-GTFB-VLA

Dialight 433-2220-001XL

Leotek TSL-12G-LX-IL6-A1

12” Red Arrow GE Lighting DR6-RTAAN-17A

Dialight 432-1314-001XOD

Leotek TSL-12RA-IL6-A1

12” Amber Arrow

GE Lighting DR6-YTAAN-17A-YX

Dialight 431-3334-901XOD

Leotek TSL-12YA-IL6-A1

12” Green Arrow

GE Lighting DR6-GTAAN-17A

Dialight 432-2324-001XOD

Leotek TSL-12GA-IL6-A1

12” Flashing Amber Arrow

GE Lighting DR6-YTAAN-17A-YX

Dialight 431-3334-901XOD

Leotek TSL-12YA-IL6-A1

PED Module GE Lighting PS7-CFF1-26A

Dialight 430-6479-001X

Leotek TSL-PED-16-CIL-9

Detection Systems: 700-5.8

Video Detection Processor

Iteris Vantage APEX

Video Detection Sensor

Iteris Vantage Apex Camera / Vantage Apex Vector (Hybrid)

Push Buttons: 700-5.9

Accessible Pedestrian

Station Approved by Agency for

Special Locations

Polara iNavigator APS, 3-wire

(New Construction)

Polara iNavigator APS, 2-wire

Closed Circuit Television (CCTV) System: 700-5.10

Camera Axis Q6315-LE 60 Hz

Axis Q6075-E 60 Hz

Arm LumenSafe Navion

Reflectorized Street Name Signs (RSNS): 700-5.11

Sign and Enclosure

Swarco SG Type

Emergency Vehicle Preempt (EVP) System: 700-5.12

Multimode Phase Selector

GTT Opticom 764

GPS Radio GTT Opticom 3100

Auxiliary Interface Panel

GTT Opticom 768

GPS Rack GTT Opticom 1040

GPS

Installation Cable

GTT Opticom 1070

SECTION 701 – CONSTRUCTION

REVISE as follows:

701-1 GENERAL. MODIFY to ADD the following:

The work shall conform to the following codes and standards:

a) California Administrative Code, Title 8, Chapter 4 subchapter 5

b) NEC

c) The State Standard Specifications and State Standard Plans, current editions

d) The CA MUTCD

ADD:

701.1.1 Equipment List and Drawings. Agency approved models are listed on the

QPL.

701-4 DAMAGE TO EXISTING

SYSTEMS. ADD:

701-4.1.1 Traffic Detectors. Existing detection shall be maintained at all times during construction. In the event of unexpected damage by the Contractor or any of their subcontractors as determined by the City Representative, the Contractor shall commence repairs immediately. The Contractor shall replace and restore to operation any damaged detector (inductive loop or other) within 24 hours after damage occurs. If at any time damage to existing presence vehicle loop detection exceeds 50%, video detection shall be installed for the entire intersection in accordance with the Special Provisions, unless otherwise approved by the Engineer.

701-11 PULL BOXES.

701-11.1 General. MODIFY to ADD the following:

a) Pull boxes shall not be installed in paved shoulder, roadway, in or within 1-foot of handicap ramps.

b) Pull boxes shall be installed in the sidewalk.

c) A grounding rod and lug shall be installed in each pull box per State Standard Specifications Section 86-2.10, providing connection for the #10 solid wire from the nearest pole.26

d) Pull box covers shall not be bolted down.

e) The B-40 communications electrical box shall include a fiber optic cable splice canister to provide for splicing of fiber optic cable. The splice canister shall be the consolidation point for all fiber optic cables and the source of the drop cable for the traffic signal cabinet fiber interconnect unit

(FIU).

701-12 CONDUIT.

701-12.1 General. MODIFY to ADD the following:

Conduit types and sizes for each application shall be as specified in 700-3.5 “Conduit” of the Standard Specifications and these Special Provisions.

Unless otherwise indicated, the depth of the conduit shall be as indicated in the table below:

Location Depth Requirement

Beneath Streets and Driveways

42-inches below finished surface or 6-inches below the deepest structural section

Back of Curb and Gutter 30-inches below top of curb

If conduits cannot be installed at required depths: Conduits shall be installed at the maximum allowable depth and encased with a minimum of 3” of concrete, unless otherwise specified by the Engineer. Conduits shall not be installed deeper than 66-inches.

All conduits shall be free from defects including non-circularity, foreign inclusions, etc. It shall be nominally uniform (as commercially practical) in color, density, and physical properties.

All conduits furnished, as part of the Contract shall be new, UL-listed, and meet NEMA and NEC requirements pertaining to electrical conduits and components.

701-13 WIRES, CONDUCTORS AND CABLES.

701-13.1 General. MODIFY to ADD the following:

The service feed from the service pull box to the electrical service shall have a tag at both ends identifying them as “City of Lake Forest Service Conductors.”

All individual conductors shall be labeled in the cabinet per NEMA numeric format.

Conductor insulation colors and wire sizes shall be in accordance with the State Standard Specifications Section 86.2.08A, “Conductor Identifications,” except as required herein.

The conditions of this subsection shall apply to all new traffic signal installations and modifications where entire signal conductor legs are re-pulled.

New traffic signal field conductors shall be multi-conductor signal cable and individual wires as specified herein and in accordance with the State Standard Specifications Sections 86-2.08D, “Signal Cable,” and 86-2.08B, “Multiple Circuit Conductors.”

New traffic signal field conductors used for phase indications and buttons shall be State standard 12CSC, 5CSC, and 3CSC multi-conductor signal cable. IMSA cable shall not be utilized. Each signal cable shall be one continuous cable from the signal cabinet to the terminal block on the signal standard it services. No splicing of signal cable shall be permitted. The signal cables shall be labeled in each pull box, per the State Standard Specifications Section 86-2.08D, and at the signal cabinet, indicating the signal standard to which it is connected.

Primary and secondary signal standards shall receive one 12CSC cable for vehicle and pedestrian indications and one 3CSC cable for each button circuit. Additional 5CSC cable shall be furnish and installed for each additional vehicle phase serviced by the pole. All 12 CSC cable conductors shall terminate on the terminal block. The 3CSC cables shall service the buttons directly. The 12CSC conductor utilization shall be in accordance with the State Standard Specifications Section 86-2.08D, with the black conductors reserved as spares. The 3CSC conductor utilization shall be blue/black stripe for pedestrian buttons, blue/orange stripe for bike buttons, and white/black stripe for common.

Pedestrian signal standards shall receive one 5CSC and one 3CSC cable. The 5CSC cable shall service the pedestrian indication and the 3CSC cable shall service button circuits.

Conductors and cables shall be as defined in the State Standard Specifications Section 86-2.08 “CONDUCTORS AND CABLES” and the Special Provisions.

a) When new conductors are added to or existing conductors removed from an existing conduit, all conductors shall be removed.

This is the start of the file's text. The full file is on GovTribe.