This notice summarizes a federal contract opportunity for construction services. The Department of Transportation Federal Highway Administration is soliciting bids for the CO FLAP PIT 82(1) Brush Creek Parking Area project through solicitation number 6982AF22B000026. Interested parties should review the attached Invitation for Bid (IFB) documents, including the CO FLAP PIT 82(1) Brush Creek Parking Area PDF, for details on responding to the solicitation by the response deadline to provide construction services for a new parking area as described in the IFB documentation. The IFB includes relevant project details, specifications, contract terms and pricing requirements for consideration and response.
View the file
Other files
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PLANS FOR PROPOSED
PROJECT MANAGER
Slopes are expressed as RISE:RUN
U.S. CUSTOMARY DIMENSIONS:
Know what'sbelow.
before you dig.Call
R www.call811.com
AND BRIDGES ON FEDERAL HIGHWAY PROJECTS, FP-14"
"STANDARD SPECIFICATIONS FOR CONSTRUCTION OF ROADS
SPECIFICATIONS:
LEAD DESIGNER
Water and Sanitary, Lighting
Grading, Aggregate Base, Asphalt Concrete Pavement, Building, TYPE OF CONSTRUCTION:
J. KNOWLES
Greeley
Sterling
Limon
Pueblo
Walsenburg
Cortez Durango
DENVER
COLORADO
SPRINGS
Steamboat
Springs
GRAND
WYOMING NEBRASKA
OKLAHOMA
NEW MEXICO
UTAH KANSAS
Trinidad
KEY MAP OF COLORADO
INTERSTATE
INTERSTATE
JUNCTION
GunnisonMontrose
PROJECT LOCATION
Project Location
4000'2000'0
Scale in Feet
PITKIN COUNTY, COLORADO
ASPEN
SPRINGS
GLENWOOD
VAIL
INTERSTATE
INTERSTATE
CO FLAP PIT 82(1)
FEDERAL HIGHWAY ADMINISTRATION
U.S. DEPARTMENT OF TRANSPORTATION
BRUSH CREEK PARKING AREA
R io G r a n d e T r a il
B ru s h C re e k T ra il
B ru s h C re e k R o a d
R o a r in g F o r k R iv e r
8.17q8.17qIndex!R2C3:R52C4J:/_Transportation/708879CH_CFL_Brush_Creek/700CADD/Roadway/CADD_Sheets/A-Gen_sht/Sheet_index_new.xls15856266251.000000rtf0.0000000.7000000.7000001.3000001.300000150.00000020.0000000.0000000.00000015.000000DefaultDefault
INDEX TO SHEETS
SHEET DESCRIPTION
S001-S512
E001-E603 ELECTRICAL SHEETS
P201-P901
A1
VOLUME II OF II
SECTION 670 BUILDING PLANS
A000-A601
M101-M901
STRUCTURAL SHEETS
ARCHITECTURAL SHEETS
MECHANICAL SHEETS
PLUMBING SHEETS
D E P
A R T
M
E
NT
OF TRANSPO
R T
A T I O
N
U N
IT
E
D STATES OF
AME
R I C
A
DENVER, COLORADO
CENTRAL FEDERAL LANDS HIGHWAY DIVISION
FEDERAL HIGHWAY ADMINISTRATION
U.S. DEPARTMENT OF TRANSPORTATION
FOR
PLANS PREPARED BY
RECOMMENDED:
DATE:
CENTRAL FEDERAL LANDS HIGHWAY DIVISION
CHIEF OF ENGINEERING
DATE:
APPROVED:
BY LETTER, DATED XX/XX/XXXX
PITKIN COUNTY PUBLIC WORKS DIRECTOR
JACOBS
INDEX CONTINUES ON A-000
OPTION Y
STATE PROJECT
P
M d e n p w p d p w ic s w o r k in g A a
T it
B C .d g n
U s e r D
E N
P W
P
NUMBER
SHEET
CO FLAP PIT 82(1)
4/14/21
08/04/2022
A. BUILDING AND DESIGN CODES:
1. 2015 INTERNATIONAL BUILDING CODE WITH THE PITKIN COUNTY CODE REQUIREMENTS.
2. AMERICAN SOCIETY OF CIVIL ENGINEERS: ASCE 7-10, MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER
STRUCTURES
3. AMERICAN INSTITUTE OF STEEL CONSTRUTION (AISC):
a. AISC 360-10, SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS
b. AISC 341-10, SEISMIC PROVISIONS FOR STRUCTURAL STEEL BUILDINGS
4. AMERICAN CONCRETE INSTITUTE: ACI 318-14, BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE
5. STEEL DECK INSTITUTE (SDI):
a. ANSI/RD1.0-10, STANDARD FOR STEEL ROOF DECK
b. SDI-QA/QC-2011, STANDARD FOR QUALITY CONTROL AND QUALITY ASSURANCE FOR INSTALLATION
OF STEEL DECK
6. AMERICAN IRON AND STEEL INSTITUTE (AISI): AISI S100-12, NORTH AMERICAN SPECIFICATION FOR THE DESIGN
OF COLD-FORMED STEEL STRUCTURAL MEMBERS, 2012
B. DESIGN LOADS:
1. FLOOR LEVEL
LIVE LOAD 60 PSF
DEAD LOAD SLAB WT + 10 PSF
2. ROOF LEVEL
LIVE LOAD 20 PSF
SNOW LOAD SEE BELOW
DEAD LOAD ROOF WT + 25 PSF
PV PANELS & RACKING 10 PSF
3. WIND LOADS:
ULTIMATE DESIGN WIND SPEED (3 SECOND GUST) Vult = 115 MPH
SURFACE ROUGHNESS CATEGORY C
ENCLOSURE CLASSIFICATION ENCLOSED
INTERNAL PRESSURE COEFFICIENT CGpi = ± 0.18
MASS DENSITY OF AIR 0.002378 SLUG/FT³
4. SNOW LOADS:
GROUND SNOW LOAD Pg = 69 PSF FLAT ROOF SNOW LOAD Pf = 53 PSF IMPORTANCE FACTOR Is = 1.0 EXPOSURE Ce = 0.9 THERMAL FACTOR Ct = 1.0
FROST DEPTH 36"
5. SEISMIC LOADS:
BUILDING RISK CATEGORY II
SITE CLASS D
MAPPED SPECTRAL RESPONSE ACCELERATIONS:
AT SHORT PERIODS SS = 0.431g AT PERIOD OF 1 SECOND S1 = 0.087g
DESIGN SPECTRAL RESPONSE ACCELERATIONS:
AT SHORT PERIODS SDS = 0.418g AT PERIOD OF 1 SECOND SD1 = 0.140g
SEISMIC DESIGN CATEGORY C
SEISMIC FORCE RESISTING SYSTEM STEEL SYSTEMS NOT SPECIFICALLY
DETAILED FOR SEISMIC RESISTANCE
RESPONSE MODIFICATION FACTOR R = 3
SEISMIC IMPORTANCE FACTOR Ie = 1.00
ANALYSIS PROCEDURE EQUIVALENT LATERAL FORCE (ELF)
SEISMIC RESPONSE COEFFICIENT Cs = 0.1395
C. GENERAL REQUIREMENTS:
1. SPECIFICATIONS ARE PART OF THE CONSTRUCTION DOCUMENTS AND MUST BE USED IN CONJUNCTION WITH
THE DRAWINGS.
2. VERIFY EXISTING CONDITIONS AND DIMENSIONS PRIOR TO BEGINNING WORK OR FABRICATING MATERIALS.
NOTIFY A/E OF DISCREPANCIES BEFORE PROCEEDING WITH ANY PHASE OF WORK.
3. VERIFY THE LOCATION OF CHASES, INSERTS, OPENINGS, SLEEVES, FINISHES, DEPRESSIONS, PADS, AND WALL
OPENINGS.
4. DO NOT SCALE DRAWINGS FOR THE PURPOSE OF ESTABLISHING DIMENSIONS.
5. DETAILS LABELED "TYPICAL DETAILS" ON DRAWINGS APPLY TO SITUATIONS OCCURRING ON THE PROJECT THAT ARE THE SAME OR SIMILAR TO THOSE SPECIFICALLY DETAILED. SUCH DETAILS APPLY WHETHER OR NOT
DETAILS ARE REFERENCED AT EACH LOCATION. NOTIFY ENGINEER OF CONFLICTS REGARDING
APPLICABILITY OF "TYPICAL DETAILS".
6. DO NOT STORE OR STACK CONSTRUCTION MATERIALS ON POURED OR ERECTED FLOORS/ROOFS IN EXCESS OF 80 PERCENT OF LIVE LOAD. GENERAL CONTRACTOR WILL ENSURE THAT ALL SUB-CONTRACTORS ARE INFORMED OF LOADING RESTRICTIONS. AVOID IMPACT WHEN PLACING MATERIALS ON POURED OR ERECTED FLOORS OR
ROOF.
7. THE CONTRACT STRUCTURAL DOCUMENTS REPRESENT THE FINISHED STRUCTURE. THE CONTRACTOR IS RESPONSIBLE FOR THE MEANS AND METHODS OF CONSTRUCTION. PROVIDE ALL MEASURES REQUIRED TO PROTECT THE STRUCTURE, WORKMEN, AND OTHER PERSONS DURING CONSTRUCTION; INCLUDING BRACING, SHORING FOR CONSTRUCTION EQUIPMENT, SHORING FOR THE BUILDING, FORMS AND SCAFFOLDING, SHORING
OF RETAINING WALLS AND OTHER TEMPORARY SUPPORTS AS REQUIRED.
8. PRINCIPAL OPENINGS THROUGH THE FRAMING ARE SHOWN ON DRAWINGS. EXAMINE THE ARCHITECTURAL AND MECHANICAL DRAWINGS FOR THE REQUIRED OPENINGS AND PROVIDE FOR REQUIRED OPENINGS WHETHER SHOWN ON THE STRUCTURAL DRAWINGS OR NOT. VERIFY SIZE AND LOCATION OF OPENINGS WITH THE MECHANICAL CONTRACTOR. DEVIATIONS FROM THE OPENINGS SHOWN ON THE STRUCTURAL DRAWINGS MUST
BE APPROVED PRIOR TO IMPLEMENTING THE CHANGES.
9. DO NOT CUT OR DRILL THROUGH EXISTING REINFORCING . X-RAY TO LOCATE REINFORCING AT LOCATIONS REQUIRING CUTTING OR CORING PRIOR TO START OF CONSTRUCTION. SUBMIT REINFORCEMENT LOCATION IN
CONFLICT WITH DRAWINGS FOR A/E REVIEW.
GENERAL NOTES
A. PROVIDE CONCRETE AS SHOWN. PROVIDE BATCH MIXING, TRANSPORTATION, PLACING AND CURING OF CONCRETE IN ACCORDANCE WITH RECOMMENDATIONS OF ACI 301, ACI 318 AND ASTM C94. USE TYPE I / II PORTLAND CEMENT UNLESS OTHERWISE NOTED. PROVIDE ADMIXTURES AND SPECIAL REQUIREMENTS AS
SPECIFIED. SEE CONCRETE MIX DESIGN SCHEDULE.
B. UNLESS SPECIFIED BELOW, CONCRETE MUST REACH THE FOLLOWING PERCENTAGES OF ITS 28 DAY COMPRESSIVE STRENGTH (F'c) BEFORE FORMS MAY BE REMOVED:
1. GRADE BEAM SIDES - 40 PERCENT
C. PROVIDE CONCRETE MIXES DESIGNED BY A QUALIFIED TESTING LABORATORY FOR REVIEW AND APPROVAL BY THE
STRUCTURAL ENGINEER.
D. PROVIDE CONSTRUCTION AND CONTROL JOINTS AS INDICATED ON DRAWINGS. HORIZONTAL CONSTRUCTION JOINTS ARE NOT ALLOWED UNLESS SPECIFICALLY NOTED OR APPROVED BY STRUCTURAL ENGINEER. NOTIFY STRUCTURAL ENGINEER OF PROPOSED CONSTRUCTION JOINT OR CONTROL JOINT LOCATIONS WHICH ARE
DIFFERENT OR IN ADDITION TO JOINTS INDICATED ON DRAWINGS.
E. CHAMFER EXPOSED EDGES 3/4 INCH UNLESS OTHERWISE NOTED.
F. WIRE BRUSH AND CLEAN CONSTRUCTION JOINTS PRIOR TO POURING NEW CONCRETE.
G. REFERENCE THE APPROPRIATE DISCIPLINE'S DRAWINGS FOR SUB SLAB PIPING, FLOOR DRAINS, AND SLAB AND
WALL PENETRATIONS.
H. FOR PIPE INSTALLED HORIZONTALLY WITHIN SLAB, PROVIDE MAXIMUM OUTSIDE DIAMETER OF 30 PERCENT OF THE SLAB THICKNESS. PLACE CONDUIT OR PIPE BETWEEN THE TOP AND BOTTOM LAYERS OF REINFORCEMENT WITHIN THE CENTER THIRD OF THE SLAB. DO NOT SPACE CONDUITS OR PIPES CLOSER THAN THREE DIAMETERS OR
WIDTHS ON CENTER.
I. PROVIDE DETAILING, FABRICATION, AND INSTALLATION OF REINFORCING AND ACCESSORIES IN ACCORDANCE
WITH ACI 315 AND ACI 318.
J. PROVIDE NEW BILLET STEEL REINFORCING BARS IN ACCORDANCE WITH ASTM A615, GRADE 60.
K. PROVIDE WELDED WIRE FABRIC IN ACCORDANCE WITH ASTM A185. LAP WELDED WIRE FABRIC TWO FULL MESH PANELS AND TIE SECURELY. PLACE WELDED WIRE FABRIC IN THE UPPER ONE-THIRD OF SLAB THICKNESS. WELDED WIRE FABRIC SHOULD BE DISCONTINUED AT ANY JOINTS. CONTRACTOR MUST ATTEND CLOSELY TO ESTABLISHING AND MAINTAINING ADEQUATE SUPPORT OF THE WELDED WIRE FABRIC REINFORCEMENT DURING THE CONCRETE PLACING OPERATIONS. WELDED WIRE FABRIC REINFORCEMENT SHOULD NOT BE LAID ON THE GROUND AND "PULLED UP" AFTER THE CONCRETE HAS BEEN PLACED, NOR SHOULD THE MATS BE "WALKED ON" AFTER PLACING THE CONCRETE. PROPER SUPPORT BAR SPACING MUST BE PROVIDED FOR THE WELDED WIRE FABRIC
REINFORCEMENT.
L. PROVIDE ANCHOR RODS CONFORMING TO THE STANDARDS OF ASTM F1554 GRADE 36 UNLESS OTHERWISE
NOTED.
M. COORDINATE PLACEMENT OF CAST-IN-PLACE EMBEDS AND ANCHOR RODS. SET ANCHOR RODS WITH A TEMPLATE.
SECURELY ATTACH EMBED ITEMS TO FORMWORK OR REINFORCING.
N. PROVIDE CLASS "B" REINFORCEMENT SPLICES FOR CONTINUOUS REINFORCEMENT. PROVIDE STANDARD 90- DEGREE HOOKS IN ACCORDANCE WITH ACI 318. STAGGER SPLICES UNLESS SPECIFICALLY NOTED OTHERWISE.
O. MAINTAIN THE FOLLOWING CONCRETE COVERAGE FOR REINFORCING STEEL UNLESS OTHERWISE NOTED:
1. CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH - 3 INCHES
2. CONCRETE EXPOSED TO EARTH OR WEATHER
a. NO. 6 AND LARGER - 2 INCHES
b. NO. 5 AND SMALLER - 1-1/2 INCHES
3. CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACT WITH THE GROUND:
a. SLABS AND WALLS
- NO. 14 AND NO. 18 - 1-1/2 INCHES
- NO. 11 AND SMALLER - 3/4 INCH
b. BEAM STIRRUPS AND COLUMN TIES - 1-1/2 INCHES
P. DO NOT WELD OR BEND REINFORCEMENT IN THE FIELD UNLESS SPECIFICALLY SHOWN OR APPROVED BY
STRUCTURAL ENGINEER.
Q. WHEN SPECIFICALLY APPROVED, PROVIDE WELDED REINFORCEMENT IN ACCORDANCE WITH ASTM A 706. USE LOW HYDROGEN ELECTRODES FOR WELDING OF REINFORCEMENT IN CONFORMANCE WITH "STRUCTURAL WELDING
CODE - REINFORCING STEEL", AMERICAN WELDING SOCIETY, AWS D1.4.
R. WHERE REQUIRED, PROVIDE DOWELS TO MATCH SIZE AND SPACING OF MAIN REINFORCING.
S. PROVIDE CONTINUOUS HORIZONTAL WALL REINFORCEMENT WITH 90-DEGREE BENDS AND EXTENSIONS AT
CORNERS AND INTERSECTIONS AS SHOWN ON TYPICAL BAR PLACING DETAILS.
T. PROVIDE BAR SUPPORT ACCESSORIES IN ACCORDANCE WITH THE LATEST ACI MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES. SUPPORT BEAM REINFORCING ON BEAM BOLSTERS
SPACED NOT MORE THAN 4 FEET ON CENTER.
U. REFER TO SPECIFICAITON SECTION 033000 3.9.D.1.a FOR FLOOR FLATNESS AND FLOOR LEVELNESS TOLERANCES.
CONCRETE NOTES
CONCRETE MIX DESIGN SCHEDULE
MIX DESCRIPTION
DAY
F'c
SLUMP
(±1")
MAXIMUM
WATER/CEMENT
RATIO
AIR
ENTRAINMENT
CEMENT TYPE FINISH CURING METHOD NOTES
FOOTINGS & STEM WALLS 4000 PSI 4" 0.40 20% 5-8% FORMED FORMED
2 4000 PSI 4" 0.45 20% 0-3% I/II TROWELINTERIOR SLAB ON GRADE
NOTES:
1. MAXIMUM AGGREGATE SIZE 3/4".
2. VERIFY SLAB FINISH WITH FLOOR FINISHES. SLAB FINISH MUST MEET SPECIFICATIONS OF FLOORING MANUFACTURER.
3. FINISH TO BE VERIFIED WITH MOCK-UP PRIOR TO CONSTRUCTION.
4. MAXIMUM AGGREGATE SIZE 3/8" FOR 5" THICK SLABS.
5. VERIFY SLAB FINISH WITH WATERPROOFING MANUFACTURER. SLAB FINISH MUST MEET SPECIFICATIONS OF WATERPROOFING MANUFACTURER.
6. CONCRETE TO CONTAIN CORROSION INHIBITING ADMIXTURE.
NOTE 6
MOIST OR MOISTURE
RETAINED (WINTER)
FLY ASH % OF
CEMENTITIOUS
BY WEIGHT
I/II NOTE 6NOTE 6
A. FOUNDATION DESIGN IS BASED UPON THE GEOTECHNICAL ENGINEERING REPORT PREPARED BY SHANNON &
WILSON (REPORT NUMBER 23-1-01458-060 DATED MARCH 24, 2020).
B. SUBGRADE PREPARATION FOR GROUND SUPPORTED SLABS AND FOUNDATIONS SHALL BE IN ACCORDANCE WITH
THE CORRESPONDING DETAILS AND DRAWINGS.
C. ALL FOUNDATION BEARING SURFACES SHALL BE OBSERVED BY A GEOTECHNICAL ENGINEER, OR DESIGNEE, TO VERIFY CONFORMANCE WITH THE CONTRACT DOCUMENTS AND GEOTECHNICAL ENGINEERING REPORT. THE
OBSERVATION SHALL BE MADE PRIOR TO PLACEMENT OF FORMS AND REINFORCING STEEL.
D. WALLS SHOWN RESTRAINED AT THE TOP SHALL NOT BE BACKFILLED UNTIL THE STRUCTURE PROVIDING RESTRAINT IS IN PLACE AND HAS ATTAINED DESIGN STRENGTH. THE CONTRACTOR SHALL BE RESPONSIBLE FOR TEMPORARY WALL BRACING WHEN BACKFILLING OCCURS PRIOR TO CONSTRUCTION OF THE TO RESTRAINT. THE CONTRACTOR SHALL PROVIDE THE ENGINEER WITH 48 HOUR MINIMUM NOTIFICATION PRIOR TO PROCEEDING
WITH RELATED WORK.
E. SOIL ULTIMATE DESIGN PARAMETERS:
1. ALLOWABLE BEARING PRESSURE = 4,500 PSF
2. PASSIVE SOIL RESISTANCE = 275 PCF
3. COEFFICIENT OF FRICTION = 0.44
FOUNDATION NOTES
STATE
CO
PROJECT
FLAP PIT 82(1)
SHEET
U.S. DEPARTMENT OF TRANSPORTATION
FEDERAL HIGHWAY ADMINISTRATION
CENTRAL FEDERAL LANDS HIGHWAY DIVISION
S-001
GENERAL NOTES
NO. PURPOSE DATE
0 100% DESIGN 08/11/21
51254
C O
LO
RA
DO REGIST ERED
P R O
F ESS IONA L EN
G I N
E E R
L E E B
A
RR
Y MA G
G E R T
8/10/2021
A. ALL DELEGATED ENGINEERING SUBMITTALS REQUIRE CONTRACTOR TO ENGAGE A QUALIFIED
PROFESSIONAL ENGINEER TO PROVIDE SIGNED AND SEALED PLANS AND CALCULATIONS TO STRUCTURAL
ENGINEER OF RECORD FOR REVIEW PRIOR TO THE START OF FABRICATION OF THE SYSTEM OR
COMPONENT PART AND PRIOR TO ANY FIELD CONSTRUCTION THAT MAY BE AFFECTED BY THE SYSTEM OF
COMPONENT PART.
B. LIGHT POLES AND BASES MUST BE DESIGNED FOR COMPLIANCE WITH GOVERNING BUILDING CODE.
CALCULATIONS SHALL BE SUBMITTED FOR REVIEW AND MUST BE SIGNED AND SEALED BY AN ENGINEER
REGISTERED IN THE STATE OF COLORADO.
C. GLAZING MUST BE DESIGNED FOR COMPLIANCE WITH GOVERNING BUILDING CODE. CALCULATIONS SHALL BE SUBMITTED FOR REVIEW AND MUST BE SIGNED AND SEALED BY AN ENGINEER REGISTERED IN THE STATE OF
COLORADO.
D. HANDRAILS MUST BE DESIGNED FOR COMPLIANCE WITH GOVERNING BUILDING CODE. CALCULATIONS SHALL BE SUBMITTED FOR REVIEW AND MUST BE SIGNED AND SEALED BY AN ENGINEER REGISTERED IN THE STATE
OF COLORADO.
E. COLD-FORMED STEEL FRAMING, INCLUDING BUT NOT LIMITED TO: WALLS, FASCIAS, CEILING, AND SOFFITS
SHALL BE DESIGNED BY A SPECIALTY ENGINEER. SHOP DRAWINGS SHALL BE SUBMITTED FOR
REVIEW AND MUST BE SIGNED AND SEALED BY AN ENGINEER REGISTERED IN THE STATE OF
COLORADO.
F. STEEL CONNECTION DESIGNS NOT DETAILED ON DRAWINGS INCLUDING SIMPLE-SHEAR, MOMENT, AND BRACE CONNECTIONS SHALL BE DESIGNED BY A LICENCED PROFESSIONAL ENGINEER WORKING FOR THE FABRICATOR PER AISC 303-10 3.1.2(3). DESIGN CALCULATIONS TO BE SEALED BY FABRICATOR'S REGISTERED PROFESSIONAL ENGINEER. SHOP DRAWINGS SUBMITTED WITHOUT COMPLETE DESIGN CALCULATIONS WILL REJECTED WITHOUT REVIEW. WHERE PREDESIGNED CONNECTIONS ARE TAKEN DIRECTLY FROM TABLES IN AISC MANUAL, CALCULATIONS NEED NOT BE SUBMITTED PROVIDED JOB DESIGN CONDITIONS PRECISELY
MATCH THOSE ASSUMED IN THE AISC MANUAL.
SPECIALTY ENGINEERING REQUIREMENTS NOTES
A. PROVIDE STRUCTURAL STEEL OF THE FOLLOWING ASTM DESIGNATIONS UNLESS OTHERWISE NOTED:
1. STRUCTURAL STEEL WIDE FLANGE AND WT SHAPES - ASTM A992.
2. STRUCTURAL STEEL STANDARD SHAPES, CHANNELS AND ANGLES - ASTM A36.
3. EDGE ANGLES, BENT PLATES, HANGER AND BRACES - ASTM A36.
4. STRUCTURAL PIPE - ASTM A53, GRADE B.
5. STRUCTURAL TUBING (SQUARE OR RECTANGULAR) - ASTM A500, GRADE B.
6. BASE PLATES AND MISCELLANEOUS STEEL PLATES - ASTM A570 Gr.50.
7. CONNECTION MATERIALS:
a. ALL CONNECTION MATERIALS, EXCEPT AS OTHERWISE NOTED HEREIN OR IN THE
DRAWINGS, INCLUDING BEARING PLATES, GUSSET PLATES, STIFFENER PLATES, ANGLES,
ETC. - ASTM A36.
8. HIGH STRENGTH BOLTS - ASTM A325, A490 OR ASTM F1852 (FULLY TENSIONED).
9. HARDENED STEEL WASHERS - ASTM F436.
10. HEAVY HEX NUTS - ASTM A563.
B. WELD MINIMUM SIZE AND STRENGTH
1. PROVIDE MINIMUM SIZE OF FILLET WELDS AS SPECIFIED IN TABLE J2.4 OF THE AISC MANUAL.
2. PROVIDE MINIMUM EFFECTIVE THROAT THICKNESS OF PARTIAL PENETRATION GROOVE WELDS
AS SPECIFIED IN TABLE J2.3 OF THE AISC MANUAL.
3. DEVELOP THE FULL TENSILE STRENGTH OF THE MEMBER ELEMENT JOINED ON ALL SHOP AND
FIELD WELDS UNLESS OTHERWISE NOTED ON THE DRAWINGS.
4. PROVIDE ELECTRODES FOR FIELD OR SHOP WELDING THAT CONFORM TO AWS D1.1 CLASS
E70XX.
C. PROVIDE MINIMUM OF TWO BOLTS PER CONNECTION. MINIMUM BOLT DIAMETER TO BE 3/4 INCH.
D. PROVIDE BOLTS, NUTS AND WASHERS THAT ARE HOT DIP GALVANIZED ACCORDING TO ASTM A153, CLASS C WHEN USED TO CONNECT STEEL ELEMENTS THAT ARE HOT DIP GALVANIZED AFTER
FABRICATION.
E. PROVIDE SIMPLE SHEAR CONNECTIONS FOR STEEL CONNECTIONS NOT OTHERWISE SPECIFIED UTILIZING HIGH STRENGTH BEARING BOLTS IN SINGLE OR DOUBLE SHEAR. PROVIDE DOUBLE ANGLE OR SINGLE PLATE SHEAR TAB BOLTED CONNECTIONS. REFER TO PLANS FOR FACTORED BEAM REACTIONS
FOR CONNECTION DESIGN.
F. STEEL FABRICATION
1. FABRICATE AND ASSEMBLE STRUCTURAL MEMBERS/ASSEMBLIES IN SHOP TO GREATEST
EXTENT POSSIBLE.
2. FABRICATOR SHALL BE RESPONSIBLE FOR ALL ERRORS OF DETAILING ON THE SHOP DRAWINGS, ERRORS IN FABRICATION, AND THE CORRECT FITTING OF STRUCTURAL STEEL MEMBERS.
G. CONFORM TO THE AISC CODE OF STANDARD PRACTICE, FOR ERECTION TOLERANCES. FIELD
MODIFICATION TO STRUCTURAL STEEL IS PROHIBITED WITHOUT PRIOR APPROVAL BY THE A/E.
H. CLEAN STEEL OF RUST, LOOSE MILL SCALE AND OTHER FOREIGN MATERIALS WHERE REQUIRED FOR
FABRICATION, FITTING UP, OR WELDING.
I. DO NOT CUT STRUCTURAL STEEL MEMBERS FOR THE WORK OF OTHER TRADES WITHOUT PRIOR
REVIEW AND APPROVAL BY THE A/E.
J. AFTER FABRICATION, HOT DIP GALVANIZE STRUCTURAL STEEL AND THEIR CONNECTIONS
PERMANENTLY EXPOSED TO THE OUTSIDE. SUCH ITEMS INCLUDE BUT ARE NOT LIMITED TO:
1. SHELF ANGLES AND STEEL LEDGERS
2. SCREEN WALL SUPPORTING MEMBERS
3. BENCH SUPPORT STEEL
4. BUILDING CLADDING SUPPORT STEEL.
STRUCTURAL STEEL NOTES
K. EXAMINE THE ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR OTHER ITEMS THAT REQUIRE HOT
DIPPED GALVANIZATION.
L. PROVIDE NON-SHRINK/NON-METALLIC GROUT FOR BASE PLATES WITH MINIMUM 28 DAY COMPRESSIVE
STRENGTH OF 5000 PSI.
M. FURNISH STEEL SHOP DRAWINGS FOR ARCHITECT'S AND STRUCTURAL ENGINEER'S REVIEW PRIOR TO
FABRICATION. INCLUDE WELDING PROCEDURES, TESTING PROGRAMS FOR WELDING AND HIGH
STRENGTH BOLTING, COATING MATERIAL, AND ERECTION SEQUENCE ON SHOP DRAWINGS.
N. MILL STEEL COLUMN ENDS TO FIT FLUSH WITH BASE PLATE, CAP PLATE, AND END PLATES. FIELD
ASSEMBLY OF THESE STEEL ELEMENTS TO THE COLUMNS IS PROHIBITED.
O. PROVIDE TEMPORARY SHORING OR BRACING DURING CONSTRUCTION PHASE PRIOR TO COMPLETING
CONNECTIONS.
A. PROVIDE DESIGN, FABRICATION, AND ERECTION OF METAL DECK CONFORMING TO THE STEEL DECK
INSTITUTE'S "CODE OF STANDARD PRACTICE".
B. FORM ROOF DECK FROM STEEL SHEETS CONFORMING A653 OR HIGHER SPECIFICATIONS WITH A MINIMUM
YIELD STRENGTH OF 33 KSI.
C. ATTACH SHEETS TO STEEL SUPPORT MEMBERS AS INDICATED AND IN ACCORDANCE WITH THE
MANUFACTURER'S INSTRUCTIONS FOR INSTALLATION.
D. LAP ROOF DECK ENDS MINIMUM OF 2 INCHES. WHEN FASTENING DECK TO SUPPORT MEMBERS, PROVIDE
WELDING MATERIALS INSTALLATION PROCEDURES TO PREVENT BURNING OF HOLES IN DECK.
E. PROVIDE 6 INCH CLOSURE STRIP WHERE CHANGES IN DECK DIRECTION OCCUR. CLOSURE TO BE SAME
GAGE AS DECK.
F. AT ENDS OF DECKS OR WHERE CHANGES OF DECK DIRECTION OCCUR, FASTEN TO SUPPORTS AT EACH
FLUTE. PROVIDE ADEQUATE CLOSURES AND FASTENERS TO SIDES AT 18 INCHES ON CENTER.
G. WHERE PARTIAL PANELS MAY BE REQUIRED TO COMPLETE DECK INSTALLATION AT PERIMETER OF STRUCTURE, PROVIDE WELDS IN EACH FLUTE TO STRUCTURAL MEMBERS. INSTALL DECK IN THREE SPAN
LENGTHS WHEREVER POSSIBLE.
H. METAL ROOF DECK:
1. SEE ROOF FRAMING PLAN NOTES FOR METAL ROOF DECK AND ITS ATTACHMENT.
METAL DECK NOTES
A. RE: SPECIFICATIONS FOR FIREPROOFING ASSEMBLIES, MATERIALS AND PROCEDURES.
FIRE-RESISTANCE RATING REQUIREMENTS TO COMPLY WITH ICC.
B. ALL STRUCTURAL ROOF FRAMING BEAMS AND JOISTS REQUIRING FIREPROOFING SHALL BE CONSIDERED
UNRESTRAINED.
C. ALL STRUCTURAL COLUMNS AND ALL STRUCTURAL MEMBERS INCLUDING BEAMS, GIRDERS AND LATERAL
BRACING CONNECTED TO STRUCTURAL COLUMNS SHALL BE CONSIDERED PRIMARY.
D. ALL MISCELLANEOUS STRUCTURAL MEMBERS SUCH AS FLOOR EDGE BRACING AND THE LIKE WHICH
SUPPORT FLOOR OR ROOF LOADS SHALL BE FIREPROOFED PER SECONDARY MEMBER CRITERIA.
FIREPROOFING NOTES
INSPECTION AND TESTS OF CONCRETE CONSTRUCTION
1. INSPECTION OF REINFORCING STEEL AND PLACEMENT. PERIODIC
CONTINUOUS
VERIFICATION AND INSPECTION TASK INSPECTION FREQUENCY
2. REINFORCING BAR WELDING.
a. VERIFY WELDABILITY OF REINFORCING BARS OTHER THAN ASTM A706
c. INSPECT ALL OTHER WELDS.
4. INSPECT ANCHORS POST-INSTALLED IN HARDENED CONCRETE MEMBERS
a. ADHESIVE ANCHORS INSTALLED HORIZONTALLY OR UPWARDLY INCLINED
ORIENTATIONS TO RESIST SUSTAINED TENSIONS LOADS.
b. MECHANICAL AND ADHESIVE ANCHORS NOT DEFINED IN 4a
5. VERIFY USE OF REQUIRED MIX DESIGN.
PRIOR TO CONCRETE PLACEMENT, FABRICATE SPECIMENS FOR STRENGTH TESTS,
PERFORM SLUMP AND AIR CONTENT TESTS, AND DETERMINE THE TEMPERATURES OF
THE CONCRETE
7. INSPECT CONCRETE AND SHOTCRETE PLACEMENT FOR PROPER APPLICATION TECHNIQUE.
8. VERIFY MAINTENANCE OF SPECIFIED CURING TEMPERATURE AND TECHNIQUES.
PERIODIC
b. INSPECT SINGLE PASS FILLET WELDS LESS THAN 5/16". PERIODIC
CONTINUOUS
PERIODIC
PERIODIC
CONTINUOUS
6.
CONTINUOUS
PERIODIC
INSPECT FORMWORK FOR SHAPE, LOCATION AND DIMENSIONS OF THE CONCRETE
MEMBER BEING FORMED.
9.
PERIODIC
INSPECTION AND TESTING FOR INSTALLATION OF STEEL DECK
SPECIAL INSPECTION AND TESTING FOR THE INSTALLATION OF STEEL DECK SHALL
BE IN ACCORDANCE WITH QUALITY CONTROL AND QUALITY ASSURANCE PLAN
REQUIREMENTS OF APPENDIX 1 - TABLES OF INSPECTION OR EXECUTION TASKS.
VERIFICATION AND INSPECTION TASK REFERENCED CRITERIA
SEE STEEL DECK INSTITUTE - 2011
STANDARD FOR QUALITY CONTROL
AND QUALITY ASSURANCE FOR
INSTALLATION OF STEEL DECK.
1.
STRUCTURAL STEEL, BOLTING, AND WELDING SPECIAL INSPECTION
SPECIAL INSPECTION OF STRUCTURAL STEEL, BOLTING, AND WELDING SHALL BE IN
ACCORDANCE WITH QUALITY CONTROL AND QUALITY ASSURANCE PLAN
REQUIREMENTS OF AISC 360-10 (CHAPTER N).
VERIFICATION AND INSPECTION TASK REFERENCED CRITERIA
SPECIAL INSPECTION OF STRUCTURAL STEEL, BOLTING, AND WELDING FOR THE
SEISMIC RESISTING SYSTEM STEEL SHALL BE IN ACCORDANCE WITH QUALITY
CONTROL AND QUALITY ASSURANCE PLAN REQUIREMENTS OF AISC 341-10
(CHAPTER J).
1.
2.
SEE AISC 360-10 FOR
ADDITIONAL AND MORE SPECIFIC
INSPECTION REQUIREMENTS.
SEE AISC 341-10 FOR
ADDITIONAL AND MORE SPECIFIC
INSPECTION REQUIREMENTS.
3. INSPECT ANCHORS CAST IN CONCRETE PERIODIC
A. ALL COLD-FORMED STEEL FRAMING SHALL BE FABRICATED AND ERECTED IN ACCORDANCE WITH
MANUFACTURER'S RECOMMENDATIONS AND IN ACCORDANCE WITH THE LATEST EDITION OF THE
"SPECIFICATION FOR THE DESIGN OF COLD-FORMED STEEL STRUCTURAL MEMBERS" BY THE AMERICAN
IRON AND STEEL INSTITUTE (AISI).
B. GALVANIZED 12, 14 AND 16 GAGE STUDS SHALL CONFORM TO ASTM A446 GRADE D WITH A MINIMUM
YIELD STRENGTH OF 50,000 PSI.
C. GALVANIZED 18 AND 20 GAGE STUDS AND ALL GALVANIZED TRACK, BRACING AND ACCESSORIES SHALL
CONFORM TO ASTM A446 GRADE A WITH A MINIMUM YIELD STRENGTH OF 33,000 PSI.
D. ALL COLD-FORMED STEEL SHALL BE GALVANIZED PER ASTM A525, G60.
E. STEEL STUD CONSTRUCTION FOR NON-BEARING PARTITION WALL SYSTEMS SHALL HAVE VERTICAL SLIP CONNECTIONS. DO NOT ATTACH THE STUDS TO THE STRUCTURE IN ANY WAY THAT WOULD PREVENT
THE STRUCTURE FROM DEFLECTING UNDER SUPERIMPOSED LOADS.
F. ALL WELDING SHALL BE PERFORMED BY WELDERS EXPERIENCED IN LIGHT-GAGE STEEL FRAMING
WORK.
COLD-FORMED STEEL FRAMING
A. EXTERIOR WALL SHEATHING SHALL BE APA RATED 7/16" OSB OR 15/32" PLYWOOD, EXPOSURE I WITH A 32/16 SPAN
RATING.
B. ATTACH SHEATHING TO COLD-FORMED METAL STUDS WITH #8 TEK SCREWS AT 6" OC ALONG PANEL EDGES AND
12" OC IN THE FIELD.
C. SHEATHING THICKNESS AND ATTACHMENT ARE MINIMUMS AND MAY BE INCREASED.
D. SHEATHING SHALL BE PLACED WITH THE 8'-0" DIMENSION PARALLEL TO STUDS FOR WALL FRAMING, STAGGER JOINTS IN ALL SHEATHING. PANEL END JOINTS SHALL OCCUR CENTERED ON A STUD. ALL SHEATHING ENDS &
EDGES SHALL HAVE A MINIMUM 1/16" AND MAXIMUM 1/8" GAP.
SHEATHING NOTES
STATE
CO
PROJECT
FLAP PIT 82(1)
SHEET
U.S. DEPARTMENT OF TRANSPORTATION
FEDERAL HIGHWAY ADMINISTRATION
CENTRAL FEDERAL LANDS HIGHWAY DIVISION
S-002
GENERAL NOTES
NO. PURPOSE DATE
0 100% DESIGN 08/11/21
51254
C O
LO
RA
DO REGIST ERED
P R O
F ESS IONA L EN
G I N
E E R
L E E B
A
RR
Y MA G
G E R
G
F
E
D
P
O
N
W
V
U
C
B
ABBREVIATIONS
A M
L
K
J
I
T
S
H
R
X
(ALL ABBREVIATIONS/SYMBOLS SHOWN ARE NOT
NECESSARILY USED ON THE DRAWINGS)
A/E
AB
ACI
ADDL
ADJ
AFF
AISC
APPROX
ARCH
ARCH'T
ASCE
ASTM
ARCHITECT/ENGINEER
ANCHOR BOLT
AMERICAN CONCRETE INSTITUTE
ADDITIONAL
ADJACENT
ABOVE FINISH FLOOR
AMERICAN INSTITUTE OF STEEL
CONSTRUCTION
APPROXIMATE (-LY)
ARCHITECTURAL
ARCHITECT
AMERICAN SOCIETY OF CIVIL
ENGINEERS
AMERICAN SOCIETY FOR
TESTING AND MATERIALS
BB
BC
BL
BACK TO BACK
BOTTOM CHORD
BASE LINE
BUILDING
BEAM
BOTTOM
BASE PLATE
BEARING
BRACKET
BOTH SIDES
BASEMENT
BEVELED
BOTH WAYS
C
CG
CGC
CGS
CJ
CL
CLR
CMU
COE
COL
CONC
CONST
CONT
CONX
COR
COMPRESSION, CHANNEL
SHAPE
CENTER OF GRAVITY
CENTER OF GRAVITY OF CONCRETE
CENTER OF GRAVITY OF STEEL
CONSTRUCTION JOINT
CENTERLINE
CLEAR, CLEARANCE
CONCRETE MASONRY UNIT
CORPS OF ENGINEER'S
COLUMN
CONCRETE
CONSTRUCTION
CONTINUOUS OR CONTINUED
CONNECTION
CONTRACTING OFFICER'S
REPRESENTATIVE
D
DETL
DIA
DIAG
DIM
DL
DN
DP
DWG
DWL
DEPTH
DETAIL
DIAMETER
DIAGONAL
DIMENSION
DEAD LOAD
DOWN
DAMP PROOFING
DRAWING (-S)
DOWEL
E
EA
EF
EJ
ELEC
ELEV, EL
EQ
EQUIP
EW
EXIST
EXP
EXT
EAST
EACH
EACH FACE
EXPANSION JOINT
ELECTRICAL
ELEVATION
EQUAL
EQUIPMENT
EACH WAY
EXISTING
EXPANSION
EXTERIOR
FAB
FD
FDN
FF
FIN
FLR
FS
FT
FTG
FABRICATION
FLOOR DRAIN
FOUNDATION
FINISH FLOOR
FINISH (-ED)
FLOOR
FAR SIDE
FOOT/FEET
FOOTING
XFMR TRANSFORMER
GA
GALV
GB
GAGE OR GAUGE
GALVANIZED
GRADE BEAM
HORIZ
HP
HS
HSS
HT
HORIZONTAL
HIGH POINT
HEADED STUD
HOLLOW STRUCTURAL
SECTION
HEIGHT
ID
IN
INT
INSIDE DIAMETER
INCH (-ES)
INTERIOR
JST
JT
JOIST
JOINT
K
KO
KIPS (1000 LBS)
KNOCKOUT
L
LB,#
LD
LDG
LH
LL
LLH
LLV
LONG
LP
LW
LWC
ANGLE SHAPE
POUND
DEVELOPMENT LENGTH
LANDING
LEFT HAND
LIVE LOAD
LONG LEG HORIZONTAL
LONG LEG VERTICAL
LONGITUDINAL
LOW POINT
LONG WAY
LIGHTWEIGHT CONCRETE
MAS
MATL
MAX
MC
MECH
MEP
MEZZ
MFR
MID
MIN
MISC
MS
MT
MTL
MASONRY
MATERIAL
MAXIMUM
MISCELLANEOUS CHANNEL
SHAPE
MECHANICAL
MECHANICAL, ELECTRICAL,
PLUMBING
MEZZANINE
MANUFACTURE (-R)
MIDDLE
MINIMUM
MISCELLANEOUS
MIDDLE STRIP
STRUCTURAL TEE CUT
FROM MISC STEEL
METAL
N/A
NF
NIC
NO
NOM
NS
NTS
NOT APPLICABLE
NEAR FACE
NOT IN CONTRACT
NUMBER
NOMINAL
NEAR SIDE
NOT TO SCALE
OA
OC
OD
OF
OPNG
OPP
OPP HND, OH
OPT
OVS
OVERALL
ON CENTER
OUTSIDE DIAMETER
OUTSIDE FACE
OPENING (-S)
OPPOSITE
OPPOSITE HAND
OPTIONAL
OVERSIZE
PC
PERP
PG
PL
PLUMB
PREFAB
PRELIM
PRMLD
PROJ
PSTG
P/T
PT
PVC
PVT
PRECAST CONCRETE
PERPENDICULAR
PLATE GIRDER
PLATE
PLUMBING
PREFABRICATED
PRELIMINARY
PREMOLDED
PROJECTION
PRESTRESSED GIRDER
POST-TENSION (-ED, -ING)
POINT
POLYVINYL CHLORIDE
PAVEMENT
R
RAD
RD
RE:
REINF
REM
REQD
REV
RH
RJ
RND
RO
RW
RIGHT, RISER
RADIUS
ROOF DRAIN
REFER TO
REINFORCING (-ED,-MENT)
REMAINDER
REQUIRED
REVISION
RIGHT HAND
RUSTICATION JOINT
ROUND
ROUGH OPENING
RETAINING WALL
S
SC
SCHED
SDI
SECT
SHT
SIM
SJ
SJI
SL
SPA
SPEC
SPL
SQ
SS
STD
STIFF
STIR
STL
STR
STRUCT
SW
SYM
SOUTH, STANDARD SHAPE
SHEAR CONNECTORS,
SLIP CRITICAL
SCHEDULE(D)
STEEL DECK INSTITUTE
SECTION
SHEET
SIMILAR
SAW JOINT
STEEL JOIST INSTITUTE
SLOPE
SPACE
SPECIFICATION(S)
SPECIAL
SQUARE
STAINLESS STEEL
STANDARD
STIFFENER
STIRRUP
STEEL
STRUCTURAL
STRUCTURE
SHEAR WALL
SYMMETRICAL
UNLESS OTHERWISE NOTEDUON
VERT VERTICAL
W
WB
w/ w/o
WP
WPJ
WT
WWF
WWM
WEST, WIDTH, WIDE FLANGE
WIND BRACE
WITH
WITHOUT
WORK POINT
WEAKENED PLANE JOINT
WEIGHT, STRUCTURAL TEE
CUT FROM WIDE FLANGE BEAM
WELDED WIRE FABRIC
WELDED WIRE MESH
T TOP, TENSION
T.O. TOP OF
T&B TOP & BOTTOM
TEMP TEMPERATURE
THRD THREADED
THK THICKNESS
TOS TOP OF STEEL
TRD TREAD (-S)
TRNV TRANSVERSE
TW TILT WALL
TYP TYPICAL
BLDG
BM
BOT
BP
BRG
BRKT
BS
BSMT
BVL
BW
EOD EDGE OF METAL DECK
EOS EDGE OF SLAB
ABBREVIATIONS (CONTINUED)
(ALL ABBREVIATIONS/SYMBOLS SHOWN ARE NOT
NECESSARILY USED ON THE DRAWINGS) STRUCTURAL SYMBOLS
DRAWING/DETAIL REFERENCE KEY
ELEVATION POINT (TOP OF
ELEMENT INDICATED)
SURFACE - SLOPE (2) WAYS
TOP OF CONCRETE EL
SURFACE - SLOPE DOWN
SURFACE - STEPPED
SURFACE - SLOPE UP
WORKPOINT
TOP OF MEMBER EL
WP
112'-0"
T.O. WALL
100'-0"
C 7/8"
THE AMOUNT OF MID-SPAN
DEAD LOAD CAMBER
MOMENT CONNECTION
[ X,Y,Z ]
[ X ]
( +3" )
SPECIAL STUD SPACING
COLUMN PASSING THRU
(DIRECTION OF SPAN)
SPACED SHEAR STUDS
TOP OF STEEL ± DEVIATION
FROM TYPICAL
NUMBER OF EVENLY
THIS LEVEL
SLOPE INDICATOR
STRUCTURAL ARROW
RE: 1/SF301
DRAWING/DETAIL REFERENCED TO
DRAWING/DETAIL NUMBER
REFER TO
DOUBLE ANGLE CONNECTION
REQUIRED IN LIEU OF SINGLE SHEAR
PLATE
1/SF301
SHEET SYMBOLS
MATERIAL GRAPHIC SYMBOLS
EARTH
NON-
SHRINK
GROUT
CAST-IN-PLACE
CONCRETE
THE FOLLOWING SYMBOLS ARE USED TO REPRESENT THE MATERIALS SHOWN ON
THE STRUCTURAL DRAWINGS. REFER TO SPECIFICATIONS AND GENERAL NOTES
FOR MATERIAL QUALITIES REQUIRED
ELEVATION OF WALL
OR FRAME
SECTION CUTS
STRUCTURAL
STEEL IN CROSS
SECTION
ENLARGED PLAN/
DETAIL REFERENCE
CMU
ROCK PRECAST CONCRETE
EXISTING
CONCRETE
STATE
CO
PROJECT
FLAP PIT 82(1)
SHEET
U.S. DEPARTMENT OF TRANSPORTATION
FEDERAL HIGHWAY ADMINISTRATION
CENTRAL FEDERAL LANDS HIGHWAY DIVISION
S-003
ABBREVIATIONS & LEGENDS
NO. PURPOSE DATE
0 100% DESIGN 08/11/21
51254
C O
LO
RA
DO REGIST ERED
P R O
F ESS IONA L EN
G I N
E E R
L E E B
A
RR
Y MA G
G E R
LEVEL 01
100'-0"
2 3 4 5 61
3'-0"3'-0"
46 5 5
LEVEL 01
100'-0"
23456 1
3'-0"
3'-0"
LEVEL 01
100'-0"
A CB
3'-0"3'-0"
4 55
LEVEL 01
100'-0"
AC B
3'-0"3'-0"
LEVEL 01
100'-0"
AC B
3'-0" 3'-0"
A
C
2 3 4 5 61
B
3'-0"
3'-0"
" 3
3 3
STATE
CO
PROJECT
FLAP PIT 82(1)
SHEET
U.S. DEPARTMENT OF TRANSPORTATION
FEDERAL HIGHWAY ADMINISTRATION
CENTRAL FEDERAL LANDS HIGHWAY DIVISION
S-010
DESIGN WIND PRESSURES
1/8" = 1'-0"S-010
5 SOUTH WIND LOAD ELEVATION
1/8" = 1'-0"S-010
2 NORTH WIND LOAD ELEVATION
1/8" = 1'-0"S-010
6 WEST WIND LOAD ELEVATION
1/8" = 1'-0"S-010
3 EAST WIND LOAD ELEVATION
1/8" = 1'-0"S-010
4 CHIMNEY WIND LOAD ELEVATION
SCREEN ZONE 6 37.38 37.38 37.38 -37.38 -37.38 -37.38
WALL ZONE 5 28.83 24.51 21.50 -38.60 -29.97 -23.94
WALL ZONE 4 28.83 24.51 21.50 -31.27 -26.96 -23.94
ROOF ZONE 3 16.61 16.00 16.00 -67.91 -53.25 -53.25
ROOF ZONE 2 16.61 16.00 16.00 -45.93 -33.71 -33.71
ROOF ZONE 1 16.61 16.00 16.00 -26.38 -23.94 -23.94
KEY ZONE 10 SF 100 SF 500 SF 10SF 100 SF 500 SF
REGION POSITIVE PRESSURE NEGATIVE PRESSURE
ULTIMATE DESIGN COMPONENTS & CLADDING WIND PRESSURES (PSF)
1/8" = 1'-0"S-010
1 ROOF WIND LOAD MAP
NOTES:
1. LINEAR INTERPOLATION IS NOT PERMITTED.
NO. PURPOSE DATE
0 100% DESIGN 08/11/21
51254
C O
LO
RA
DO REGIST ERED
P R O
F ESS IONA L EN
G I N
E E R
L E E B
A
RR
Y MA G
G E R
A
C
2 3 4 5 61
B
S-201
14'-6" 14'-6" 14'-6" 14'-6" 14'-6"
F7272
F4848
F4848
F4848
F7272 F4848 F4848 F4848
F4848 F4848
F4848
F48156
S-201
T.O. SLAB = 100'-0"
S-201
________3
S-201
S-201
S-501
S-501
OPP
F4848 6
3"
3"
T.O. PIER= 100'-6"
T.O. PIER= 100'-6"
S-501
T.O. WALL= 100'-0" ,TYP UNO
T.O. LEDGE = 99'-8" ,TYP UNO
T.O. FOOTING 98'-0" ,TYP UNO
W A
L L
10"
10"
T.O. WALL= 100'-0"
T.O. LEDGE = 99'-8"
T.O. WALL= 99'-0"
T.O. WALL= 99'-0"
S-501
6"
6"
W
A L
L
T Y
P U
N O
L E
D G
E T
Y P
U N
O
3"
T.O. WALL= 101'-0"
04 05
T.O. PIER= 99'-0"
T.O. PIER= 99'-0"
1'-0"
1'-0"
T.O. LEDGE = 99'-8"
T.O. WALL= 100'-0"
"9
F T
G T
Y P
U N
O
1'-6" 1'-6"
T.O. SLAB = 99'-8 3/4"
2.071%
2.071%
T.O. SLAB = 99'-8 3/4"
S-501
S-501
SLOPE
SLOPE
/2
/2
3'-2 1/4" 4" 5 1/2"
/2
/2
3'-2 1/4" 4" 5 1/2"
-1
/2
-1
/2
-1 1/2"
-1 1/2"
T.O. WALL= 101'-0"
STATE
CO
PROJECT
FLAP PIT 82(1)
SHEET
U.S. DEPARTMENT OF TRANSPORTATION
FEDERAL HIGHWAY ADMINISTRATION
CENTRAL FEDERAL LANDS HIGHWAY DIVISION
S-101
FOUNDATION PLAN
1/4" = 1'-0"S-101
1 FOUNDATION PLAN
A. TOP OF FLOOR SLAB ELEVATION = 100'-0" TYP UNO.
B. SEE STRUCTURAL NOTES AND ABBREVIATIONS FOR ADDITIONAL INFORMATION.
C. MAINTAIN STRUCTURAL SLAB THICKNESS AT ALL FLOOR SLOPES, STEPS, AND
DEPRESSIONS.
D. REFERENCE ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS NOT SHOWN.
E. REFERENCE PLUMBING DRAWINGS FOR FLOOR DRAINS, SANITARY RISERS, AND
SANITARY VENTS.
GENERAL NOTES:
FOOTING SCHEDULE
DESIGNATION LENGTH WIDTH THICKNESS REINFORCING
F4848 4'-0" 4'-0" 1'-0" (5) #5 EACH WAY BOTTOM
F7272 6'-0" 6'-0" 1'-0" (7) #5 EACH WAY BOTTOM
F48156 13'-0" 4'-0" 1'-0" (14) #5 TRANSVERSE, (5) #5 LONGITUDINAL BOTTOM
KEYED NOTES:
01 5" SLAB ON GRADE REINFORCED WITH
4X4-W1.4xW1.4 WELDED WIRE REINFORCING
ON RIGID INSULATION ON SUBGRADE
PREPARATION PER GEOTECHNICAL REPORT. SLAB
REINFORCING TO BE LOCATED MID-THICKNESS OF
SLAB W/ 3/4"ø MAX. RADIANT TUBING PLACED ON
TOP OF REINFORCING.
02 COLUMN BASE TYPE A. REFER TO DETAIL 1/S-503.
03 COLUMN BASE TYPE B. REFER TO DETAIL 2/S-503.
04 COLUMN BASE TYPE C. REFER TO DETAIL 3/S-503.
05 COLUMN BASE TYPE D. REFER TO DETAIL 4/S-503.
06 COLUMN BASE TYPE E. REFER TO DETAIL 5/S-503.
07 COLUMN BASE TYPE F. REFER TO DETAIL 6/S-503.
08 COLUMN BASE TYPE G. REFER TO DETAIL 7/S-503.
09 SAW-CUT CONTROL JOINT. REFER TO DETAIL
1/S-502.
10 (2) #4 X 4'-0" AT RE-ENTRANT SLAB CORNERS.
CENTER LENGTH AT CORNER AND SPACE 2" OC.
13 CONCRETE MECHANICAL HOUSEKEEPING PAD.
REFER TO DETAIL 2/S-502.
14 REINFORCE FOOTING SIMILAR TO F4848.
15 PROVIDE 2'-0"X2'-0" BENT CORNER BARS TO MATCH
SIZE AND SPACING OF WALL HORIZONTAL
REINFORCING.
NO. PURPOSE DATE
0 100% DESIGN 08/11/21
NOTE: FOOTINGS ARE CENTERED ON COLUMNS ABOVE UNLESS NOTED OTHERWISE.
51254
C O
LO
RA
DO REGIST ERED
P R O
F ESS IONA L EN
G I N
E E R
L E E B
A
RR
Y MA G
G E R
WOMENS
RESTROOM
MENS
RESTROOM
MENS
VESTIBULE
ELECTRICAL /
SECURITY
MECHANICAL /
JANITOR
WOMENS
VESTIBULE
CHASE
A
C
2 3 4 5 61
B
W X
W X
W X
W X
W X
C8x11.5
C x .5
C x .5
W27X84
W8X18
W X
W X
5 W
X
W X
W X
W X
W X
W X
W X
W X
W8X18 W8X18 W8X18 W8X18
W8X18W8X18W8X18W8X18W8X18
W8X15 W8X15
W X
W X
W X
W X
W X
W8X15
W8X15
C x .5
W X
W X
W X
W X
W8X15 W8X15
C8x11.5 C8x11.5C8x11.5
C x .5
H S
S X
X
/4
H S
S X
X
/4
S-201
S-201
S-201
S-201
14'-6" 14'-6" 14'-6" 14'-6" 14'-6"
7'-3" 7'-3" 4'-10" 2'-5" 2'-5" 4'-10" 4'-10" 2'-5" 2'-5" 4'-10" 4'-10" 2'-5" 2'-5" 4'-10" 7'-3" 7'-3"
SPLICE
3'-0"
SPLICE
3'-0"
S-201
SPLICE
3'-3"
EOD
3'-7 1/2"
EOD
2'-5 1/2"
C8x11.5
C8x11.5
C8x11.5
E O
D
/2
S-511
S-511
E O
D
/2
B.O. DECK @ RIDGE = 114'-9"
OPP
S-511
S-511
34K 34K
HSS4X4X1/4
(T.O. STEEL = 107'-0")
HSS4X4X1/4
(T.O. STEEL = 107'-0")
HSS4X4X1/4
(T.O. STEEL = 107'-0")
HSS4X4X1/4
(T.O. STEEL = 107'-0")
H S S 4x4x1/4
H
SS
4x 4x
1/
H S S 4x4x1/2
H
SS
4x 4x
1/
H
SS
4x 4x
1/
H S S 4x4x1/2
H
SS
4x 4x
1/
H
SS
4x 4x
1/
H
SS
4x 4x
1/
H S S 4x4x1/4
W 8x
W 8x
H
SS
4x 4x
1/
W X
W X
W8X15 W8X15
W8X15W8X15H
SS
3x 3x
1/
H
SS
3x 3x
1/
H
SS
3x 3x
1/
H
SS
3x 3x
1/
H
SS
3x 3x
1/
H
SS
3x 3x
1/
S-512
W X
W X
W X
W X
W X
W X
W X
W X
W X
W X
W X
C8x11.5
W X
H
SS
4x 4x
1/
H
SS
4x 4x
1/
M C
X
.3
H S S 4x4x1/4 H
SS
4x
4x 1/
H
SS
4x 4x
1/
H
SS
4x 4x
1/
M = ±26 K-FT
(ULTIMATE)
M = ±26 K-FT
(ULTIMATE)
11" 11"
W8X15
W8X15
S-511
SIM
(L O
W
(L O
W
H S
S X
X
/4
(L O
W
S-512
H
SS
4x 4x
1/
A. TOP OF STEEL ELEVATION TO MATCH BOTTOM OF DECK
ELEVATION AS NOTED ON PLAN UNO.
B. REFERENCE ARCHITECTURAL DRAWINGS FOR ROOFING
MATERIAL, SCUPPERS, FLASHING, AND TRIM.
C. SEE STRUCTURAL GENERAL NOTES AND ABBREVIATIONS FOR
ADDITIONAL INFORMATION.
D. COORDINATE ALL ROOF OPENING LOCATIONS AND SIZES
WITH ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND
PLUMBING DRAWINGS.
GENERAL NOTES:
STATE
CO
PROJECT
FLAP PIT 82(1)
SHEET
U.S. DEPARTMENT OF TRANSPORTATION
FEDERAL HIGHWAY ADMINISTRATION
CENTRAL FEDERAL LANDS HIGHWAY DIVISION
S-102
ROOF PLAN
1/4" = 1'-0"S-102
1 ROOF FRAMING PLAN
KEYED NOTES
11 3N18 METAL DECK ATTACHED TO SUPPORTS WITH HILTI
X-ENP-19 POWDER-ACTUATED FASTENERS IN 24/4
PATTERN & 6" OC @ EDGES PERIMETER W/ (3) #10 TEK
SCREWED SIDE LAP CONNECTIONS PER SPAN.
12 BOLTED SHEAR PLATE CONNECTIONS PER
CONTRACTOR'S SPECIALTY ENGINEER. MINIMUM
DESIGN SHEAR VERTICAL SHEAR LOAD (UP OR DOWN)
TO BE 15K (ULTIMATE) UNO. MINIMUM (2) BOLTS PER
CONNECTION.
NO. PURPOSE DATE
0 100% DESIGN 08/11/21
51254
C O
LO
RA
DO REGIST ERED
P R O
F ESS IONA L EN
G I N
E E R
L E E B
A
RR
Y MA G
G E R
B.O. TRANSOM
107'-0"
AC B
HSS4X4X1/4 HSS4X4X1/4
W8X31 W8X31
H S
S x x /2
H S
S x x /2
HSS4X4X1/4 HSS4X4X1/4
H S
S x x /2
S-512
SIM
T = C = 19 KIPST = C
= 19 K
IPS
S-511
S-511
S-511
S-503
S-503
LEVEL 01
100'-0"
AC B
S-201
W x
W x
W8X35 W8X35
S-511
S-511
S-501
S-501
S-511
M = ±46 K-FT M = ±46 K-FT
LEVEL 01
100'-0"
AC B
HSS4X4X1/4
H
SS4X
4X 1/
HSS4X4X1/4
H S
S x x /4
H S
S x x /4
W8X67
W8X67
S-511
S-501
S-512
SIM
S-503
ROTATE
90°
S-512
T = C = 16 KIPS
T = C
6 K
IP
S
LEVEL 01
100'-0"
B.O. TRANSOM
107'-0"
2 31
HSS4X4X1/4
H
SS4X
4X 1/
4 H
SS4X4X1/4 H
S S x x /4
H S
S x x /2
HSS4X4X1/4
HSS4X4X1/4
H S
S X
X
/4
7'-3" 7'-3"
TYP
1'-9 3/4"
S-512
SIM
S-503
S-503
T = C
K
IP
S T = C
= 4 K
IP
S
STATE
CO
PROJECT
FLAP PIT 82(1)
SHEET
U.S. DEPARTMENT OF TRANSPORTATION
FEDERAL HIGHWAY ADMINISTRATION
CENTRAL FEDERAL LANDS HIGHWAY DIVISION
S-201
FRAMING ELEVATIONS
1/4" = 1'-0"S-201
4 BRACED FRAME - GRID 2
1/4" = 1'-0"S-201
3 MOMENT FRAME - GRID 1
1/4" = 1'-0"S-201
1 BRACED FRAME - GRID 6
1/4" = 1'-0"S-201
2 BRACED FRAME - GRID A & C
NO. PURPOSE DATE
0 100% DESIGN 08/11/21
51254
C O
LO
RA
DO REGIST ERED
P R O
F ESS IONA L EN
G I N
E E R
L E E B
A
RR
Y MA G
G E R
S-201
CONCRETE SLAB
EXPANSION JOINT
CAP AND SEALANT
STEEL COLUMN
6" COLD-FORMED METAL FRAMING
STUD WALL BY CONTRACTOR'S
SPECIALTY ENGINEER
MASONRY LEDGE WHERE
INDICATED ON PLAN
9"
4"
RIGID INSULATION
SUBGRADE PER
GEOTECHNICAL
REPORT
" #5 AT 12" OC EA FACE
PER SCHEDULE
(4) #5 U BARS @ COLUMN
LOCATIONS, TYPICAL
#5 CONT
#4 TIES @ 12" OC
LEVEL 01
100'-0"
CONCRETE SLAB
1/2" EXPANSION
JOINT CAP AND
SEALANT
4"
6" COLD-FORMED METAL FRAMING
STUD WALL BY CONTRACTOR'S
SPECIALTY ENGINEER
MASONRY LEDGE
WHERE INDICATED
ON PLAN
9"
RIGID INSULATION
SUBGRADE PER
GEOTECHNICAL
REPORT
2'-0"
#5 AT 12" OC EA FACE
HOOK ENDS AT
BOTTOM
#4 @ 18" OC TRANSVERSE
(3) #5 LONGITUDINAL
CONTINUOUS
#5 CONT
LEVEL 01
100'-0"
CONCRETE SLAB
RIGID INSULATION
SUBGRADE PER
GEOTECHNICAL
REPORT
6"
2'-0"
/2
#5 AT 12"OC
HOOKED INTO
FOOTING
(2) #5 TOP AND
BOTTOM
#4 @ 18" OC TRANSVERSE
(3) #5 LONGITUDINAL
CONTINUOUS
LEVEL 01
100'-0"
CONCRETE SLAB
EXPANSION JOINT
CAP AND SEALANT
RIGID INSULATION
SUBGRADE PER
GEOTECHNICAL
REPORT
6" 2"
PLACE STEM WALL IN
(2) POURS TO ALLOW
COLUMNS AT GRID 6 TO
BE INSTALLED AT 99'-0".
2'-0"
/2
#5 AT 12" OC EA FACE
#4 @ 18" OC TRANSVERSE
(3) #5 LONGITUDINAL
CONTINUOUS
HOOK ENDS AT BOTTOM
LEVEL 01
100'-0"
S-201
9" 9"
CONCRETE SLAB
STEEL COLUMN
FOOTING REINFORCING
PER SCHEDULE
#4 TIES @ 12" OC
PER SCHEDULE
(8) #6 VERTICAL
HOOKED INTO FOOTING
3/16
(6) #5 U BARS
(3 EACH WAY)
(3) #4 TIES @ 3" OC
@ TOP OF PIER
HOOK BARS AT ENDS
LEVEL 01
100'-0"
S-201
CONCRETE SLAB
STEEL COLUMN
6" COLD-FORMED METAL FRAMING
STUD WALL BY CONTRACTOR'S
SPECIALTY ENGINEER
MASONRY LEDGE WHERE
INDICATED ON PLAN
HOOK ENDS AT
TOP AND BOT
PER SCHEDULE
4" 4"
#5 AT 12" OC EA FACE
STATE
CO
PROJECT
FLAP PIT 82(1)
SHEET
U.S. DEPARTMENT OF TRANSPORTATION
FEDERAL HIGHWAY ADMINISTRATION
CENTRAL FEDERAL LANDS HIGHWAY DIVISION
S-501
FOUNDATION DETAILS
3/4" = 1'-0"S-501
1 FOUNDATION AT COLUMN
3/4" = 1'-0"S-501
2 FOUNDATION WITH MASONRY LEDGE
3/4" = 1'-0"S-501
4 FOUNDATION AT DOOR
3/4" = 1'-0"S-501
3 FOUNDATION AT VESTIBULE
3/4" = 1'-0"S-501
5 FOUNDATION @ MOMENT FRAME
3/4" = 1'-0"S-501
6 FOUNDATION AT GRID 6
NO. PURPOSE DATE
0 100% DESIGN 08/11/21
51254
C O
LO
RA
DO REGIST ERED
P R O
F ESS IONA L EN
G I N
E E R
L E E B
A
RR
Y MA G
G E R
CONCRETE SLAB
CONCRETE SLAB
CONTROL JOINT
CONSTRUCTION JOINT
SAW CUT SLAB SOON ENOUGH
TO PREVENT CRACKING AND LATE
ENOUGH TO PREVENT SPALLING.
FILL WITH SEALANT.
3/4" DIA. x 12" SMOOTH
DOWEL AT 24"
KEYWAY
TERMINATE EVERY OTHER
REINFORCING BAR.
"T
6" 6"
1' - 0" 1' - 0"
6" 6"
"T
#4 AT 24" O.C. EACH WAY
DRILL AND EPOXY 3"
INTO SLAB
CONCRETE
HOUSEKEEPING SLAB
WITH #3 AT 18" EACH WAY
CENTERED
CONCRETE SLAB ON
GRADE
HOUSEKEEPING SLAB AT STRUCTURAL SLAB
COORDINATE PAD
SIZE WITH
EQUIPMENT
3/4" CHAMFER AT
EXPOSED EDGES
/2
/2
STATE
CO
PROJECT
FLAP PIT 82(1)
SHEET
U.S. DEPARTMENT OF TRANSPORTATION
FEDERAL HIGHWAY ADMINISTRATION
CENTRAL FEDERAL LANDS HIGHWAY DIVISION
S-502
FOUNDATION DETAILS
3/4" = 1'-0"S-502
1 TYPICAL SLAB JOINTS
3/4" = 1'-0"S-502
2 TYPICAL CONCRETE HOUSEKEEPING SLAB
NO. PURPOSE DATE
0 100% DESIGN 08/11/21
51254
C O
LO
RA
DO REGIST ERED
P R O
F ESS IONA L EN
G I N
E E R
L E E B
A
RR
Y MA G
G E R
STEEL COLUMN
1/4
3/4" THICK BASE PLATE
STEEL COLUMN
1 1/2" THICK GROUT
3/4"X9"X1'-2" EMBED PLATE
W/ (4) 3/4" HEADED STUDS
(3" EDGE DISTANCE TO CONCRETE)
PER PLAN
T.O. CONCRETE
(4) 3/4"ø THREADED ROD
IN STANDARD HOLES
6" 6"
2" 2"
CL COL.
GRID
CL COL.
GRID
FOUNDATION WALL
1/4
TYP
/4
/2
/4
3" 5" 5" 3"
FOUNDATION WALL
STEEL COLUMN
1/4
3/4" THICK BASE PLATE
STEEL COLUMN
CONCRETE PEDESTAL
PER PLAN
T.O. CONCRETE
5" 5"
2" 2"
CL COL.
GRID
CL COL.
GRID
1 1/2" THICK GROUT
3/4"X1'-0"X1'-0" EMBED PLATE
W/ (4) 3/4" HEADED STUDS
(3" EDGE DISTANCE TO CONCRETE)
1/4
TYP
/4
/2
/4
3" 6" 3"
(4) 3/4"ø THREADED ROD
IN STANDARD HOLES
CONCRETE PEDESTAL
STEEL COLUMN
1/4
3/4" THICK BASE PLATE
STEEL COLUMN
1 1/2" THICK GROUT
3/4"X9"X1'-2" EMBED PLATE
W/ (4) 3/4" HEADED STUDS
(3" EDGE DISTANCE TO CONCRETE)
PER PLAN
T.O. CONCRETE
(4) 3/4"ø THREADED ROD
IN STANDARD HOLES
10" 2 1/2"
2" 4"
CL COL.
GRID
CL COL.
GRID
FOUNDATION WALL
1/4
TYP
/4
/2
/4
3" 8" 3"
FOUNDATION WALL
STEEL COLUMN
1/4
3/4" THICK BASE PLATE
STEEL COLUMN
1 1/2" THICK GROUT
3/4"X1'-0"X1'-0" EMBED PLATE
W/ (4) 3/4" HEADED STUDS
(3" MIN EDGE DISTANCE TO
CONCRETE)
PER PLAN
T.O. CONCRETE
(4) 3/4"ø THREADED ROD
IN STANDARD HOLES
/2
8" 2 1/2"
CL COL.
GRID
CL COL.
GRID
FOUNDATION WALL
/2
1/4
TYP
/4
/2
/4
3" 6" 3"
2"
2 1/2"
2"
PIER
SECONDARY POUR
@ STEM WALL
SLAB ON GRADE
1/4
3/4" THICK BASE PLATE
STEEL COLUMN
1 1/2" THICK GROUT
3/4"X9"X2'-0" EMBED PLATE
W/ (6) 3/4" HEADED STUDS
(3" EDGE DISTANCE TO CONCRETE)
PER PLAN
T.O. CONCRETE
(6) 3/4"ø THREADED ROD
IN STANDARD HOLES
1'-4" 6"
/4
2" 4"
CL COL.
GRID
CL COL.
GRID
FOUNDATION WALL
1/4
TYP
/4
/2
/4
3" 9" 5" 4" 3"
GUSSET PL 3/4"
HSS BRACE
1/4
1/4
TYP
1'-1"
2"
FOUNDATION WALL
3/4" THICK BASE PLATE
STEEL COLUMN
1 1/2" THICK GROUT
3/4"X9"X2'-0" EMBED PLATE
W/ (6) 3/4" HEADED STUDS
(3" EDGE DISTANCE TO CONCRETE)
PER PLAN
T.O. CONCRETE
(11) 3/4"ø THREADED ROD
IN STANDARD HOLES
1'-4"6"
/4
2"4"
CL COL.
GRID
CL COL.
GRID
FOUNDATION WALL
/4
/2
/4
3"9"5"4"3"
GUSSET PL 3/4"
HSS BRACE
1'-1"
2"FOUNDATION WALL
9"
1 1/4"
2"
1/4
1/4
TYP
1/4
1/4
TYP
TYP
1/4
3/4" THICK BASE PLATE
STEEL COLUMN
1 1/2" THICK GROUT
3/4"X9"X2'-0" EMBED PLATE
W/ (6) 3/4" HEADED STUDS
(3" EDGE DISTANCE TO CONCRETE)
PER PLAN
T.O. CONCRETE
(6) 3/4"ø THREADED ROD
IN STANDARD HOLES
1'-4" 6"
2" 4"
CL COL.
GRID
CL COL.
GRID
FOUNDATION WALL
1/4
TYP
/4
/2
/4
3" 9" 5" 4" 3"
GUSSET PL 3/4"
HSS BRACE
1/4
1/4
TYP
1'-1"
2"
FOUNDATION WALL
STATE
CO
PROJECT
FLAP PIT 82(1)
SHEET
U.S. DEPARTMENT OF TRANSPORTATION
FEDERAL HIGHWAY ADMINISTRATION
CENTRAL FEDERAL LANDS HIGHWAY DIVISION
S-503
BASE PLATE DETAILS
1" = 1'-0"S-503
2 COLUMN BASE PLATE - TYPE B
1" = 1'-0"S-503
1 COLUMN BASE PLATE - TYPE A
1" = 1'-0"S-503
3 COLUMN BASE PLATE - TYPE C
1" = 1'-0"S-503
4 COLUMN BASE PLATE - TYPE D
1" = 1'-0"S-503
5 COLUMN BASE PLATE - TYPE E
1" = 1'-0"S-503
6 COLUMN BASE PLATE - TYPE F
1" = 1'-0"S-503
7 COLUMN BASE PLATE -TYPE G
NO. PURPOSE DATE
0 100% DESIGN 08/11/21
51254
C O
LO
RA
DO REGIST ERED
P R O
F ESS IONA L EN
G I N
E E R
L E E B
A
RR
Y MA G
G E R
B
DECK
BEAM
SINGLE-PLATE SHEAR
CONNECTION, TYPICAL
5/16" CONTINUOUS
BENT PLATE @ RIDGE
MATCH ROOF SLOPE
1/4 2-12
1/4 2-12
B
METAL DECK. FASTEN
PER PLAN NOTE.
SINGLE-PLATE SHEAR
CONNECTION, TYPICAL
CHANNEL FASCIA BEAM
MITER AT RIDGE
RIDGE BEAM
CJP
5/16" CONTINUOUS
BENT PLATE @ RIDGE
MATCH ROOF SLOPE
1/4 2-12
1/4 2-12
B.O. TRANSOM
107'-0"
S-201
BEAM
DECK
CHANNEL FASCIA BEAM
BEAM
COLUMN
8"X8"X3/4" CAP PLATE
W/ (4) 3/4"⌀ BOLTS
3/8" CONTINOUS
BENT PLATE
TYP
TYP
4"
T.O. CAP
118'-8"
B
L5X3-1/2X3/8 CONTINUOUS LEDGER (LLV)
(L7X4X3/8 LLH @ EAST & WEST FACES OF SIM)
SLOPE W/ ROOF @ ENDS & MITER CORNERS
W/ CJP WELD
BEAM BEAM
12"X4"X3/4" BASE PLATE
W/ (4) 3/4"⌀ BOLTS
HSS POST
HSS3X3X1/4
CONTINUOUS
P
E R
A R
C H
5/16" CONTINUOUS
BENT PLATE @ RIDGE
MATCH ROOF SLOPE
HSS3X3X1/4
STONE CLIPS ATTACHED TO COLD-
FORMED METAL FRAMING BY
CONTRACTOR'S SPECIALTY ENGINEER
MC4X13.8 CONTINUOUS LEDGER
W/ 3/8"X3"X4" PLATE @ EACH POST
MITER CORNERS W/ CJP WELD
HSS3X3X1/4
CONTINUOUS
HSS3X3X1/4
NOTES:
1. AT SIM, OMIT FRAMING ABOVE CAP
3"
1/4
1/4 2-12
1/4
FASTEN DECK PER PLAN
SINGLE-PLATE SHEAR
CONNECTION, TYPICAL
3 SIDES
CONTINUITY PLATES TO MATCH
THICKNESS OF COLUMN FLANGES
B
5/16" CONTINUOUS
BENT PLATE @ RIDGE
MATCH ROOF SLOPE
SINGLE-PLATE SHEAR
CONNECTION, TYPICAL
CJP, TYP
1/4
1/4 2-12
FASTEN DECK PER PLAN
L4x4x3/8
STEEL JOISTS
OR BEAMS
COORD W
ITH
UNIT C
URB
L3 1/2x3 1/2x3/8
L4x4x3/8
NOTE:
ANGLES SHALL BE LOCATED UNDER EQUIPMENT PER MANUFACTURER'S RECOMMENDATION.
1/8 2"
1/4
WELD 3 SIDES
CO
O
RDINATE
O
PENING
S W
ITH
UNIT CURB
STATE
CO
PROJECT
FLAP PIT 82(1)
SHEET
U.S. DEPARTMENT OF TRANSPORTATION
FEDERAL HIGHWAY ADMINISTRATION
CENTRAL FEDERAL LANDS HIGHWAY DIVISION
S-511
FRAMING DETAILS
3/4" = 1'-0"S-511
4 ROOF RIDGE AT COLUMN
3/4" = 1'-0"S-511
2 ROOF RIDGE AT FASCIA
3/4" = 1'-0"S-511
3 ROOF EAVE
3/4" = 1'-0"S-511
1 ROOF RIDGE AT CHIMNEY
3/4" = 1'-0"S-511
5 MOMENT CONNECTION AT COLUMN
1 1/2" = 1'-0"S-511
6 ROOF RIDGE AT MOMENT FRAME
NTSS-511
7 TYPICAL ROOF PENETRATION FRAMING
NO. PURPOSE DATE
0 100% DESIGN 08/11/21
51254
C O
LO
RA
DO REGIST ERED
P R O
F ESS IONA L EN
G I N
E E R
L E E B
A
RR
Y MA G
G E R
WP
BEAM
COL. SYM.
GRID
GUSSET PL 3/4"
TYP
2" MIN
M
IN
10" MIN
8" M
IN
2" M
IN
HSS 4X4 BRACING
TYP
TYP
TYP
DETAIL IS MIRRORED ABOUT
COLUMN CENTERLINE
AT SIM, BEAM IS CONTINUOUS
W/ COLUMN WELDED TO
BOTTOM FACE
B.O. TRANSOM
107'-0"
(2) 1/2"ø BOLTS CENTERED IN
VERTICAL LONG-SLOTTED
HOLES, SNUG TIGHTEN
L6X3-1/2X5/16 EACH SIDE (LLV)
3/16
3/16
3/16
3 SIDES
3/16
3/16
STONE VENEER
1/4"X3"X7-1/2" PLATE EACH SIDE
STONE CLIPS ATTACHED TO COLD-
FORMED METAL FRAMING BY
CONTRACTOR'S SPECIALTY ENGINEER
CFS FRAMING INFILL
BETWEEN HSS BY
CONTRACTOR'S
SPECIALTY ENGINEER.
CFS FRAMING NOT
SHOWN FOR CLARITY.
C
1/4
1/4
COLUMN PER PLAN
1/2"X24" PLATE
BOTTOM EDGE TAPERED
10-1/2" @ CHANNEL
5-1/2" @ FREE END
MC6X18
BENCH FASTENED TO
BRACE THE PLATE
1"x12"x12" STL PLATE
1/2"x12" PLYWOOD
3/4"x12"x12" PLYWOOD
1"x12"x12" STL PLATE
3/4"x12"x12" FABREEKA -TIM
1/2"x10-1/2"x6" STL PLATE
(4) 3/4" BOLTS
1/4
1/4
1/4
1/4
4"4"
1"x4"x20" STL PLATE
WP
COL. SYM.
GUSSET PL 3/4"
HSS BRACE
TYP
2"
8" M
IN
3/4"X8"X2'-0" CAP PLATE
W/ (8) 3/4"ø BOLTS
1/4
3/16
3/16
COLUMN PER PLAN
3/8"X3-3/4"X6" PLATE
MC6X18
3/8"X2-1/4"X6" PLATE
3/16
3/16
(2) 1/2"ø BOLTS
ATTACHMENT OF CHANNEL TO
COLUMN TO OCCUR @ TOP OF
CHANNEL & 4'-0" MAX VERTICALLY
/2
6"
1/4" OUTRIGGER PLATE EACH
SIDE OF DOWNSPOUT. REFER
TO ARCHITECTURAL
DRAWINGS FOR GEOMETRY.
1/4"X4-1/2" PLATE EACH SIDE OF
DOWNSPOUT. ATTACH W/ 3/16"
FILLET WELDS.
1/4"X6"X2'-0" COVER PLATE ABOVE.
ATTACH W/ 3/16" FILLET WELDS.
TYP
1/4" PLATE EACH SIDE OF
DOWNSPOUT. MATCH DEPTH
OF OUTRIGGER PLATE. ATTACH
W/ 3/16" FILLET WELDS.
STATE
CO
PROJECT
FLAP PIT 82(1)
SHEET
U.S. DEPARTMENT OF TRANSPORTATION
FEDERAL HIGHWAY ADMINISTRATION
CENTRAL FEDERAL LANDS HIGHWAY DIVISION
S-512
FRAMING DETAILS
1" = 1'-0"S-512
1 GUSSET @ TRANSOM BEAM-TO-COLUMN
3/4" = 1'-0"S-512
3 STEEL LINTEL
1" = 1'-0"S-512
4 BENCH SUPPORT
1" = 1'-0"S-512
2 GUSSET @ ROOF BEAM-TO-COLUMN
1" = 1'-0"S-512
5 ARCHITECTURAL CHANNEL ATTACHMENT
1" = 1'-0"S-512
6 OUTRIGGER @ DOWNSPOUT
NO. PURPOSE DATE
0 100% DESIGN 08/11/21
51254
C O
LO
RA
DO REGIST ERED
P R O
F ESS IONA L EN
G I N
E E R
L E E B
A
RR
Y MA G
G E R
08.11.21
STATE
CO
PROJECT
FLAP PIT 82(1)
SHEET
U.S. DEPARTMENT OF TRANSPORTATION
FEDERAL HIGHWAY ADMINISTRATION
CENTRAL FEDERAL LANDS HIGHWAY DIVISION
A-000
DRAWING INDEX
ARCHITECTURAL
SHEET # DRAWING TITLE
100% DESIGN -
09/11/20
A-000 DRAWING INDEX ●
A-001 GENERAL NOTES & LIFE SAFETY ●
A-002 GRAPHIC STANDARDS & MOUNTING HEIGHTS ●
A-003 ASSEMBLY TYPES ●
A-101 SITE PLAN ●
A-102 FLOOR PLAN ●
A-103 REFLECTED CEILING PLAN ●
A-104 ROOF PLAN ●
A-201 EXTERIOR ELEVATIONS ●
A-202 EXTERIOR ELEVATIONS ●
A-203 INTERIOR ELEVATIONS & FINISH SCHEDULES ●
A-301 BUILDING SECTIONS ●
A-302 WALL SECTIONS ●
A-401 ENLARGED PLANS ●
A-501 PLAN DETAILS ●
A-502 SECTION DETAILS ●
A-503 SECTION DETAILS ●
A-504 SECTION DETAILS ●
A-505 DOOR & WINDOW DETAILS ●
A-506 DOOR & WINDOW DETAILS ●
A-601 DOOR & WINDOW SCHEDULE/TYPES ●
STRUCTURAL
SHEET # DRAWING TITLE
100% DESIGN -
09/11/20
S-001 GENERAL NOTES ●
S-002 GENERAL NOTES ●
S-003 ABBREVIATIONS & LEGENDS ●
S-010 DESIGN WIND PRESSURES ●
S-101 FOUNDATION PLAN ●
S-102 ROOF PLAN ●
S-201 FRAMING ELEVATIONS ●
S-501 FOUNDATION DETAILS ●
S-502 FOUNDATION DETAILS ●
S-503 BASE PLATE DETAILS ●
S-511 FRAMING DETAILS ●
S-512 FRAMING DETAILS ●
MECHANICAL
SHEET # DRAWING TITLE
100% DESIGN -
09/11/20
M-001 HVAC LEGEND 1 OF 2 ●
M-002 HVAC LEGEND 2 OF 2 ●
M-101 AIRFLOW SCHEMATIC ●
M-102 HYDRONIC SCHEMATIC ●
M-201 HVAC FLOOR PLAN ●
M-202 HYDRONIC PIPING FLOOR PLAN ●
M-203 EXTERIOR HYDRONIC PIPING PLAN ●
M-204 HVAC AND HYDRONIC PIPING ROOF PLAN ●
M-301 SECTIONS ●
M-501 DETAILS ●
M-502 DETAILS ●
M-503 DETAILS ●
M-504 DETAILS ●
M-505 DETAILS ●
M-506 DETAILS ●
M-601 SCHEDULES ●
M-901 HYDRONIC PIPING OVERALL ISOMETRIC ●
ELECTRICAL
SHEET # DRAWING TITLE
100% DESIGN -
09/11/20
E-001 GENERAL NOTES ●
E-101 SITE POWER PLAN ●
E-102 SITE LIGHTING PLAN ●
E-103 SITE PHOTOMETRIC PLAN ●
E-104 BUILDING POWER PLAN ●
E-105 BUILDING LIGHTING PLAN ●
E-501 ELECTRICAL DETAILS ●
E-601 LUMINAIRE SCHEDULE ●
E-602 SINGLE LINE DIAGRAM ●
PLUMBING
SHEET # DRAWING TITLE
100% DESIGN -
09/11/20
P-001 PLUMBING LEGEND 1 OF 2 ●
P-002 PLUMBING LEGEND 2 OF 2 ●
P-201 PLUMBING FLOOR PLAN ●
P-501 DETAILS ●
P-502 DETAILS ●
P-503 DETAILS ●
P-901 PLUMBING - OVERALL ISOMETRIC ●
A-000
1 BUILDING ISOMETRIC
NO. PURPOSE DATE
0 100% DESIGN 08/11/21
WOMENS
RESTROOM
MECHANICAL /
JANITOR
ELECTRICAL /
SECURITY
MENS
VESTIBULE
MENS
RESTROOM
WOMENS
VESTIBULE
EXIT ACCESS
TRAVEL DISTANCE =
45'-9" ø 5' - 0" ø 5' - 0"
BLUE HATCH REPRESENTS
1 HR RATED WALL.
FIRE EXTINGUISHER CABINET
CODE SUMMARY
APPLICABLE CODES:
2015 INTERNATIONAL BUILDING CODE (IBC)
2015 INTERNATIONAL FIRE CODE (IFC)
2015 INTERNATIONAL PLUMBING CODE (IFC)
2015 INTERNATIONAL MECHANICAL CODE (IMC)
2015 INTERNATIONAL ENERGY CONSERVATION CODE (IECC)
2017 NATIONAL ELECTRICAL CODE (NEC)
2009 ICC A117.1 (ANSI)
OCCUPANCY CLASSIFICATION: UTILITY (U)
CONSTRUCTION TYPE: V-B
FIRE SPRINKLER SYSTEM: NOT PROVIDED
GROSS BUILDING AREA: 1,172 SF
OCCUPANT LOAD: (PER TABLE 1004.1.2)
ASSUMED: ACCESSORY STORAGE AREAS, MECHANICAL
EQUIPMENT ROOM
1,172 SF / 300 GSF/OCC = 4 OCCUPANTS MINIMUM
PROVIDING FOR: 16 OCCUPANTS TOTAL, 8 PER SEX
TOTAL EXIT ACCESS TRAVEL DISTANCE:
300' ALLOWED (PER TABLE 1017.2), 45'-9" ACTUAL
MAXIMUM COMMON PATH OF EGRESS TRAVEL:
SHALL NOT EXCEED 100' (PER TABLE 1006.2.1)
MINIMUM REQUIRED EGRESS WIDTH: PER SECTION 1005.3.2
OTHER EGRESS COMPONENTS
16 OCCUPANTS X 0.2 = 3.2" REQUIRED, 36" PROVIDED
ALLOWABLE HEIGHT AND AREA: PER TABLE 504.3, 504.4, & 506.2
ALLOWABLE HEIGHT: 1 STORY, 40 FEET
ALLOWABLE AREA: 5,500 SF PER FLOOR
ACTUAL HEIGHT: 1 STORY, 22'-11"
ACTUAL AREA: 1,172 SF
MAXIMUM OCCUPANT LOAD FOR SPACES WITH ONE EXIT:
49 OCCUPANTS (PER TABLE 1006.2.1)
DEAD END CORRIDORS: PER SECTION 1020.4
SHALL NOT EXCEED 20' WHERE NOT SPRINKLERED
FIRE RESISTANCE RATING REQUIREMENTS: PER TABLE 601
PRIMARY STRUCTURE = 0 HRS
BEARING WALLS = 0 HRS
NON BEARING WALLS = 0 HRS
FLOOR = 0 HRS
ROOF = 0 HRS
INTERIOR FINISH REQUIREMENTS: PER TABLE 803.11
EXIT PASSAGEWAYS = NO RESTRICTIONS
CORRIDORS FOR EXIT ACCESS STAIRWAYS = NO RESTRICTIONS
ROOMS AND ENCLOSED SPACES = NO RESTRICTIONS
PLUMBING FIXTURES COUNT PER 2902.1:
PLUMBING FIXTURE COUNTS WERE DETERMINED USING THE
FOLLOWING RATIONALE. A DWELL TIME OF 90 SECONDS FOR MEN
& 120 SECONDS FOR WOMEN. WITH A TYPICAL 5-MINUTE BUS
TRANSFER TIME, THE RESTROOMS CAN ACCOMMODATE 13 MEN &
10 WOMEN WHICH IS ABOUT 1/3 OF THE BUS PASSENGERS. WITH
PEOPLE ARRIVING FROM CARS AND TRANSFERRING BUSES, 8
TOTAL FIXTURES WITH THE ABILITY TO EXPAND IN THE FUTURE
WAS DETERMINED TO BE ADEQUATE.
GENERAL NOTES
1. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS AND NOTES SHALL ESTABLISH ALL LOCATIONS. LARGER SCALE DRAWINGS SHALL
HAVE PRECEDENCE OVER SMALLER SCALE DRAWINGS.
2. VERIFY EXISTING CONDITIONS AND TO NOTIFY THE A/E OF ANY DISCREPANCIES.
3. REFER TO APPLICABLE SECTIONS OF THE SPECIFICATIONS FOR ADDITIONAL INFORMATION AND REQUIREMENTS.
4. ELEVATIONS SHOWN ARE FOR REFERENCE AND COORDINATION. FINISHED FLOOR ELEVATION 100'-0" EQUALS THE CIVIL ELEVATION OF
7551.95 FEET.
5. EXISTING UTILITIES SHOWN ON THESE PLANS ARE APPROXIMATE. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO LOCATE AND
PROTECT EXISTING UTILITIES FROM THE CONSTRUCTION ACTIVITIES OF THIS CONTRACT.
6. NOTIFY ALL UTILITIES AFFECTED BY THIS CONTRACT PRIOR TO BEGINNING CONSTRUCTION.
7. EXECUTION OF WORK UNDER THE TERMS AND CONDITIONS OF THESE CONTRACT DOCUMENTS REQUIRES COORDINATION WITH
OTHER CONTRACTORS.
8. ALL WORK UNDER THE TERMS OF THESE CONSTRUCTION DOCUMENTS SHALL COMPLY WITH THE APPROPRIATE RELEVANT SECTIONS
OF THE STANDARD OSHA REGULATIONS.
9. ALL WORK AND MATERIALS ARE SUBJECT TO INSPECTION BY THE OWNER OR ENGINEER INDEPENDENT OF THE CONTRACTOR'S QUALITY CONTROL PROGRAM. UNSATISFACTORY WORK OR MATERIALS ARE SUBJECT TO REJECTION AND REPLACEMENT AT NO
ADDITIONAL COST TO THE OWNER.
10. DEVELOP AND SUBMIT FOR APPROVAL IN ADVANCE…