Checklist.pdf
PDF 134 KB Posted
- Attached to
- ICN OSP Project # 77244807, Polk Co
- Solicitation number
- 26-032
- Issued by
- Polk County, Iowa
About this file
This is a Construction Site Inspection Checklist for the Iowa Communications Network (ICN) OSP Project #77244807 in Polk County, a City of Des Moines cable relocation project managed by the ICN. The checklist provides a comprehensive quality assurance framework for inspecting fiber optic cable installation and related infrastructure work. The document outlines required inspections across six major categories: excavated areas (backfill, restoration, debris removal), installation-related items (cable/conduit depth and positioning, marker installation), handhole installation (grade setting, base preparation, conduit clearance, and sealing), cable installation (damage assessment, bend radius verification, coiling, and snap-around placement), locate facilities (ground rod installation, bonding, tracer wire routing, and facility testing), and building entrance/terminations (conduit securing, penetration sealing, grounding, fiber panel installation, and proper labeling). Each category contains specific checkpoints that must be verified during construction site inspections to ensure compliance with project standards.
The checklist serves as a quality control and compliance verification document without addressing pricing terms, set-asides, funding sources, or contractual pricing arrangements. The document functions as an operational tool for project management and inspection protocols rather than as a solicitation or award document containing procurement-specific information such as cost, incumbent status, or funding details.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 26-032 ITB OSP.docx | DOCX document | |
| SOW.docx | DOCX document | |
| Typicals.pdf | ||
| Engineering Plans.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Iowa Communications Network
Construction Site Inspection Checklist
Excavated Areas
• backfilled, restored, & tamped
• lawn restored
• concreted restored
• trash/debris removed
Installation Related Items
• cable/conduit at proper depth
• located within row
• markers installed
Handhole(s) Installation
• set at grade or provide depth
• crushed rock in base
• wire mesh on top of rock
• conduit(s) min. 6-in above rock
• conduit(s) plugged
• pull rope installed
• tracer wire conduit plugged
• backfilled / compacted
Cable Installation
• any visible damage to cable
• bend radius maintained
• cable properly coiled
• snap arounds installed
Locate Facilities
• ground rod installed per standards
• #6 bare copper bonded with ground clamp
• tracer wire routed into closure
• directions labeled
• locate facility tested and verified
Building Entrance/Terminations
• exterior conduit secured
• penetrations sealed
• locate facility installed (if appl)
• #10 ground to ground bar
• #10 grounded properly (lug)
• fiber panel installed correctly
• bulkhead installed correctly
• panel(s) labeled
• cable routed correctly