This document is a Fire Alarm Reporting Diagram schematic for a Siemens Desigo system serving multiple facilities. The diagram illustrates a networked fire alarm infrastructure connecting nine facilities across different locations: Trinity Powerplant, Shasta Powerplant, Shasta Dam, Shasta Upper Vista House, Lewiston Powerplant, Shasta Maintenance Center, JF Carr Powerplant, Spring Creek Powerplant, Keswick Powerplant, and Keswick Office Building. Each facility is equipped with a Siemens IP DACT (IP Digital Alarm Communicator Transmitter) and is connected via VoIP phone lines to a local area network/wide area network (LAN/WAN) infrastructure. The system architecture includes a central Bosch Receiver with PC located at Shasta Powerplant, which serves as the primary monitoring and control hub for the distributed fire alarm system.

The schematic indicates that the scope of work encompasses seven facilities (Spring Creek Powerplant, Shasta Powerplant, and associated LAN/WAN connections noted within a dashed box boundary). The system utilizes a Bosch D1218 Battery with 12VDC-18AH capacity for backup power at the panel level. All facilities communicate through VoIP phone lines connected to their respective LAN/WAN networks, enabling centralized monitoring and alarm reporting. This configuration represents a comprehensive, multi-site fire alarm communication network designed to provide redundant connectivity and centralized alarm management across the Reclamation facility portfolio.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Desigo

SIEMENS

IP DACT

Desigo

SIEMENS

IP DACT

Desigo

SIEMENS

IP DACT

Desigo

SIEMENS

IP DACT

Desigo

SIEMENS

IP DACT

Desigo

SIEMENS

IP DACT

Desigo

SIEMENS

IP DACT

Desigo

SIEMENS

IP DACT

Desigo

SIEMENS

IP DACT

Desigo

SIEMENS

IP DACT

SHEET NOTES (RSN 51 00 20)

BOSCH D1218 BATTERY

12VDC - 18AH

BATTERY

PANEL

+ A

LW

A

YS

T H

IN

K

S A

FE

TY

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

Managing

LAR M TA IOCE N

W in theWa estter

M. VELASQUEZM. HOPKINS

44OP-274238

NICET #112434 / LEVEL IV

BONG KEOMUANGTAI, S.E.T.

FIRE ALARM SYSTEM

SIEMENS

Fax (916) 447-4724

Smart Infrastructure /

West Sacramento, California 95691 3650 Industrial Boulevard, Suite 100

Tel (916) 553-4444

SACRAMENTO OFFICE

U.L. Certificate ID No. 324787-001

Fire Safety Division

California State C10 License No. 758796

RE

G

IS

TE

RED C - 10 L I CENSED CONTRACTOR

S T

A T

E O F C A L I F O R

N I A

S I E

M

E NS B L DG T E C HNOLOG

I ESLIC. NO. 758796

REV DESCRIPTION BY DATE

C

EN

TR

A L

V A

LL

EY

P

R O

JE

C T

S

PR

IN

G

C R

EE

K P

O W

ER

PL

A N

T

FI

R E

A

LA

R M

R

EP

LA

C

EM

EN

T

FIRE ALARM

REPORTING DIAGRAM

PROJECT NO.

FA3-00-SCPP

20-C0893

NICET #112434 / LE//// VEL

BONG KEOMUANGTAI,

FIRE ALARM SYSTEM

File details come from the government source that posted it. Updated .