C03. Drawings - Electrical.pdf

PDF 22 MB Posted

Attached to
Y1NB--Renovate Operating Rooms - VAMC Cleveland
Solicitation number
Not on record
Issued by

About this file

This document provides details on a federal contract award notice. The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 10 awarded contract number 36C25020C0076 to BRIGADIER CONSTRUCTION SERVICES, LLC on September 29, 2020 for $6,979,000. The contract is for renovations to the operating rooms at the Veterans Affairs Medical Center in Cleveland, Ohio. The awarded contract and project details are contained in file C03. Drawings - Electrical.pdf, which includes electrical drawings related to the operating room renovation project.

View the file

Other files

Show all 21

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ABBREVIATIONS

GENERAL ELECTRICAL SPECIFICATION NOTES:

DEDICATED NEUTRAL CONDUCTORS

AC ABOVE COUNTER AT 9" UNLESS OTHERWISE NOTED

AF AMP FRAME

AFC ABOVE FINISHED CEILING

AFF ABOVE FINISHED FLOOR

AT AMP TRIP

BC BELOW COUNTER AT 18"AFF UNLESS OTHERWISE NOTED

BFC BELOW FINISHED CEILING

CM CEILING MOUNTED

EC ELECTRICAL CONTRACTOR

EG EQUIPMENT GROUND

GC GENERAL CONTRACTOR

GFCI GROUND FAULT CIRCUIT INTERRUPTER

IG ISOLATED GROUND

ITD INFORMATION TECHNOLOGY DEPARTMENT

PROVIDE DEFINITION: FURNISH, INSTALL AND CONNECT COMPLETE.

X EXISTING OUTLET, DEVICE, LIGHTING FIXTURE, CONDUIT, ETC. - TO REMAIN

XB INDICATES EXISTING OUTLET, LIGHTING FIXTURE, CONDUIT, ETC - TO BE REMOVED.

PROVIDE BLANK COVER FOR OUTLET AND MAINTAIN CIRCUIT CONTINUITY.

XL NEW LOCATION OF EXISTING OUTLET, DEVICE, LIGHTING FIXTURE, ETC.

XN EXISTING OUTLET, DEVICE, LIGHTING FIXTURE, ETC. - TO BE REPLACED WITH NEW OF

SPECIFIED TYPE

XR EXISTING OUTLET, DEVICE, LIGHTING FIXTURE, CONDUIT, ETC. - TO BE REMOVED COMPLETE-

MAINTAIN CIRCUIT CONTINUITY TO ADJACENT OUTLETS, EXTEND CONDUIT AND WIRING AS

REQUIRED.

XRR EXISTING OUTLET, DEVICE, LIGHTING FIXTURE, ETC. - TO BE REMOVED AND REINSTALLED

AT NEW LOCATION - EXTEND CONDUIT AND WIRING AS REQUIRED

MC MECHANICAL CONTRACTOR

MLO MAIN LUGS ONLY

NEC NATIONAL ELECTRICAL CODE

NF NOT FUSED

OFE OWNER FURNISHED EQUIPMENT

TC TELECOMMUNICATIONS CONTRACTOR

TCC TEMPERATURE CONTROLS CONTRACTOR

TV TELEVISION

VDC VOICE/DATA CONTRACTOR

VFD VARIABLE FREQUENCY DRIVE

WM WIREMOLD

WP WEATHERPROOF ENCLOSURE - NEMA 4

DEDICATED NEUTRAL CONDUCTORS ARE REQUIRED FOR ALL 120V AND 277V BRANCH CIRCUITS. MULTIWIRE BRANCH

CIRCUITS WITH SHARED NEUTRAL CONDUCTORS ARE NOT PERMITTED.

ROUTE NO MORE THAN (3) BRANCH CIRCUIT HOMERUNS PER EACH CONDUIT RUN.

THE FOLLOWING ITEMS SUPERCEDE ITEMS WITHIN THE SPECIFICATIONS:

ALL FIRESTOPPING MATERIAL SHALL BE MANUFACTURED BY STI. ALL INSTALLERS SHALL BE CERTIFIED INSTALLERS OF STI

FIRESTOPPING PRODUCTS AND HAVE PROOF OF CERTIFICATION.

THE USE OF HOSPITAL GRADE HCF CABLE IS PERMITTED FOR CONNECTION TO FIXED EQUIPMENT (LIGHTING FIXTURES, SURGICAL BOOMS,ETC). THE LENGTH IS LIMITED TO 6 FEET.

THE FOLLOWING SYSTEM CABLING IS PERMITTED TO BE INSTALLED IN THE CABLE TRAY SYSTEM:

A. TEL/DATA CABLING

B. HOSPITAL PAGING SYSTEM

ALL OTHER SPECIAL SYSTEMS CABLING (FIRE ALARM AND SECURITY) SHALL BE INSTALLED IN A COMPLETE CONDUIT

SYSTEM. E.C SHALL GROUND CABLE TRAY IN ACCORDANCE WITH N.E.C. ARTICLE 250.96.

GENERAL ELECTRICAL INSTALLATION NOTES:

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

ALL MOUNTING HEIGHTS ARE TO CENTER OF DEVICE UNLESS OTHERWISE NOTED.

ALL NEW WALL MOUNTED ELECTRICAL DEVICES ARE TO BE INSTALLED FLUSH IN WALL UNLESS OTHERWISE NOTED.

ALL ELECTRICAL CONDUIT SHALL BE CONCEALED BEHIND FINISHED WALLS AND ABOVE FINISHED CEILING UNLESS OTHERWISE NOTED. THE COST TO CUT AND PATCH WALLS SHALL BE THE RESPONSIBILITY OF THE TRADE

REQUIRING THE CUTTING.

CONTRACTOR IS RESPONSIBLE FOR REMOVAL AND REPLACEMENT OF CEILINGS REQUIRED FOR ELECTRICAL WORK.

CONTRACTOR SHALL REPLACE ANY DAMAGED CEILING TILES.

PRIOR TO INSTALLATION, VERIFY PRECISE LOCATION OF NEW OR RELOCATED WALL OR CEILING MOUNTED DEVICES

WITH ARCHITECTURAL ELEVATIONS AND REFLECTED CEILING PLANS.

COORDINATE ALL SHUT-DOWNS OF EXISTING ELECTRICAL SYSTEMS WITH OWNER A MINIMUM OF FOURTEEN (14) WORKING DAYS IN ADVANCE. ALL SHUT-DOWNS SHALL OCCUR DURING WEEKENDS OR BETWEEN 8:00PM AND 7:00AM

ON WEEKDAYS ("OFF-HOURS"). INCLUDE ALL PREMIUM TIME CHARGES IN BID.

ALL NOISE GENERATING OPERATIONS, INCLUDING CUTTING OF CEILINGS, WALLS AND FLOORS, CORING, DRILLING, ETC. SHALL BE SCHEDULED DURING WEEKENDS OR BETWEEN 8:00PM AND 7:00AM ON WEEKDAYS ("OFF-HOURS").

INCLUDING ALL PREMIUM TIME CHARGES IN BID.

CONTRACTOR SHALL CONNECT ALL MECHANICAL EQUIPMENT COMPLETE PER MANUFACTURER'S WIRING DIAGRAMS AND INSTRUCTIONS. COORDINATE WITH MECHANICAL CONTRACTOR AND VERIFY LOCATION, VOLTAGE, AMPS, NO. OF WIRES, AND PROTECTION REQUIREMENTS PRIOR TO ROUGH-IN. CONTACT ENGINEER WITH ANY DISCREPANCIES

FROM DESIGN DRAWINGS.

PROVIDE LIQUID-TIGHT FLEXIBLE METAL CONDUIT FOR FINAL CONNECTION TO MECHANICAL EQUIPMENT OR OTHER

EQUIPMENT WHICH MAY PROPAGATE VIBRATION.

ALL FLUORESCENT LAMPS THAT WILL NOT BE REUSED SHALL BE DISPOSED OF IN ACCORDANCE WITH EPA STANDARDS, AND WRITTEN EVIDENCE OF PROPER DISPOSAL SHALL BE FURNISHED TO THE OWNER.

ALL WORK SHALL BE PERFORMED IN STRICT CONFORMANCE WITH THE PHASING REQUIREMENTS OF THE PROJECT.

ALL COSTS ASSOCIATED WITH THESE REQUIREMENTS SHALL BE INCLUDED IN THE BID SUBMITTAL.

CONTRACTOR IS RESPONSIBLE FOR PROVIDING TEMPORARY LIGHTING TO ADEQUATELY LIGHT ALL CONSTRUCTION AREAS, TEMPORARILY PARTITIONED AREAS, AND EXIT CORRIDORS MAINTAINED DURING CONSTRUCTION.

DEFINITION: "PROVIDE" - FURNISH, INSTALL AND CONNECT COMPLETE.

PROJECT AND PHASING SCOPE LINES INDICATE WHERE GENERAL CONSTRUCTION BOUNDARIES OCCUR.

ELECTRICAL WORK AND UTILITY TIE-INS MAY OCCUR OUTSIDE OF SCOPE LINES.

C. NURSE CALL CABLING

D. CATV

CPT CONTROL POWER TRANSFORMER

ETR EXISTING TO REMOVE

COR CONTRACTING OFFICER'S REPRESENTATIVE

OS

D

LIGHTING CONTROLS

20A-1P-120/277V WALL SWITCH - MOUNTED AT 48" AFF UNLESS OTHERWISE NOTED

20A-3WAY-120/277V WALL SWITCH MOUNTED AT 48" UNLESS OTHERWISE NOTED

277V SINGLE POLE 0-10VDC LOW-VOLTAGE LARGE PADDLE SWITCH WITH SMALL DIMMER SLIDER, AUTOMATICALLY RETURNS TO PRESET LEVEL - ENGRAVING LABEL - MOUNTED AT 48" AFF UNLESS OTHERWISE NOTED. VERIFY ALL

SWITCHES ARE COMPATIBLE WITH FIXTURE TYPE.

277V SINGLE POLE, 3-WAY, 0-10VDC LOW-VOLTAGE LARGE PADDLE SWITCH WITH SMALL DIMMER SLIDER, AUTOMATICALLY RETURNS TO PRESET LEVEL - MOUNTED AT 48" AFF UNLESS OTHERWISE NOTED. VERIFY ALL

SWITCHES ARE COMPATIBLE WITH FIXTURE TYPE.

DUAL TECHNOLOGY OCCUPANCY SENSOR - PROVIDE COMPLETE OCCUPANCY SENSOR SYSTEM INCLUDING SENSOR, POWER SUPPLY AND RELAY UNIT. REFER TO " OCCUPANCY SENSOR PROGRAM SCHEDULE" AND "OCCUPANCY SENSOR SYSTEM SPECIFICATION" FOR ADDITIONAL INFORMATION. PROVIDE FORM C RELAY IN RELAY UNIT IN ALL OCCUPANCY

SENSORS FOR HVAC SWITCHING.

RELAY DESIGNATIONS

# - PROVIDE RELAY WITH NORMALLY OPEN (N.O.) CONTACT(S), # DENOTES THE QUANTITY OF N.O. RELAYS. IF BLANK, PROVIDE (1) N.O. RELAY.

OTHER DESIGNATIONS

L - "LINEAR COVERAGE", TWO SIDED, 90 LINEAR FT. COVERAGE

NOTE: REFER TO "DEVICE AND WALL PLATE DETAIL" FOR ADDITIONAL INFORMATION.

S

S

S

3DS

MOTOR AND MOTOR CONTROLLERS (FLOOR PLAN VIEW)

COMBINATION CIRCUIT BREAKER MAGNETIC MOTOR STARTER COMPLETE WITH "HAND-OFF-AUTO" SELECTOR SWITCH,

(2) AUX CONTACTS, CPT AND RED "RUN" PILOT LIGHT IN COVER. NEMA SIZE 0 CONTACTS AND NEMA 1 ENCLOSURE

MINIMUM UNLESS OTHERWISE NOTED.

VARIABLE SPEED DRIVE MOTOR CONTROLLER - (REFER TO SPECIFICATIONS SECTION 262911).

120V -1ø OR 277V -1ø (AS REQUIRED) MANUAL MOTOR STARTER WITH INTEGRAL OVERLOAD PROTECTION.

120V -1ø OR 277V -1ø (AS REQUIRED) MANUAL MOTOR STARTER WITH INTEGRAL OVERLOAD PROTECTION AND "HANDS-

OFF-AUTO"

120V -1ø OR 277V -1ø (AS REQUIRED) LOCKABLE MANUAL SWITCH (NO THERMAL OVERLOADS).

CONTROLLER FURNISHED WITH EQUIPMENT

VSMC

ST

STHOA

SML

POWER DISTRIBUTION EQUIPMENT

208/120V-3PH-4W-SN PANELBOARD UNLESS OTHERWISE NOTED

480/277V-3PH-4W-SN PANELBOARD UNLESS OTHERWISE NOTED

ISOLATED POWER PANELBOARD

SPECIAL PANEL OR PULLBOX - SIZE AND TYPE AS NOTED

NON-FUSED DISCONNECT SWITCH - SIZE AND TYPE AS NOTED

FUSED DISCONNECT SWITCH - SIZE AND TYPE AS NOTED, WITH TYPE RK1 FUSES

GROUNDING BUSBAR

GB

IPP-XX

WIRING DEVICES

TV

20A-125V, HOSPITAL GRADE, GROUNDED DUPLEX RECEPTACLE, MOUNTED IN (2) GANG BACKBOX AT 18" UNLESS

OTHERWISE NOTED. CONNECTED TO NORMAL POWER

DOUBLE 20A-125V, HOSPITAL GRADE, GROUNDED DUPLEX RECEPTACLES, MOUNTED IN (2) GANG BACKBOX AT 18" UNLESS

OTHERWISE NOTED. CONNECTED TO NORMAL POWER.

20A-125V, HOSPITAL GRADE, GROUND FAULT (GF) INTERRUPTER TYPE RECEPTACLE, MOUNTED IN A (2) GANG BACKBOX AT

18" UNLESS OTHERWISE NOTED. CONNECTED TO NORMAL POWER

20A-125V, HOSPITAL GRADE, GROUNDED DUPLEX RECEPTACLE, MOUNTED IN (2) GANG BACKBOX. COORDINATE EXACT

MOUNTING HEIGHT WITH ARCHITECT PRIOR TO ROUGH-IN. CONNECTED TO NORMAL POWER

20A-125V, HOSPITAL GRADE, TAMPER RESISTANT GROUNDED DUPLEX RECEPTACLE, MOUNTED IN (2) GANG BACKBOX AT

18" UNLESS OTHERWISE NOTED. CONNECTED TO NORMAL POWER.

SAME DEVICE TYPES AS INDICATED ABOVE EXCEPT SHADING INDICATES DEVICE IS CONNECTED TO EMERGENCY CIRCUIT

SPECIAL OUTLETS - TYPES AS NOTED ON PLANS

POWER GROUND MODULE - PROVIDE CONFIGURATION AS INDICATED ON ELECTRICAL DETAILS. INCLUDE HOSPITAL GRADE DUPLEX RECEPTACLES (RED), STAINLESS STEEL FRONT FACE, GALVANIZED BACKBOX PROVIDED BY EC. COVERPLATE SHALL BE ENGRAVED INDICATING PANEL NAME AND SUPPLYING PANEL AND CIRCUIT NUMBER FOR EACH RECEPTACLE.

MOUNT FLUSH IN WALL AT 24" AFF.

NOTE: REFER TO "DEVICE AND WALL PLATE DETAIL" FOR ADDITIONAL INFORMATION.

TR

PG

WIRE TERMINATIONS

JJ JUNCTION BOX, CEILING OR WALL MOUNTED, 4" SQ. WITH GROUND LUG, UNLESS OTHERWISE NOTED:

MGA - MEDICAL GAS ALARM PANEL. CONNECT TO 120V, 20A LIFE SAFETY CIRCUIT. WALL MOUNTED.

VAV - VARIABLE AIR VOLUME TERMINALS. SEE PLANS FOR ADDITIONAL WORK INFORMATION AND WORK REQUIREMENTS AD - AUTOMATIC DOOR. JUNCTION BOX ABOVE CEILING. EC SHALL CONNECT AUTOMATIC DOOR INCLUDING PUSH PAD.

TCP - TEMPERATURE CONTROL PANEL. FURNISHED AND INSTALLED BY MC. EC SHALL PROVIDE 120V CONNECTION.

SLC - SURGICAL LIGHT CONTROLLER - CONNECT TO 120V,20A-1P CIRCUIT. WALL MOUNTED COORDINATE BACKBOX AND

HEIGHT WITH MANUFACTURER PRIOR TO ROUGH IN.

MOTOR - HORSEPOWER AND VOLTAGE AS NOTED

JUNCTION BOX MOUNTED AT 48" AFF FOR CONNECTION TO AUTOMATIC DOOR PUSH PAD DEVICE. PROVIDE 3/4"C TO DOOR

CONTROLLER WITH WIRING PER MANUFACTURER'S REQUIREMENTS.

3/4" MINIMUM SIZE CONCEALED CONDUIT WITH #12 AWG, THWN STRANDED COPPER CONDUCTORS PLUS SEPARATE #12 GROUND ( ), AND CONDUIT WIRE FILLS IN ACCORDANCE WITH N.E.C. - EMT MAY BE USED IN INTERIOR STUD WALLS, AND ABOVE FINISHED CEILINGS. DEDICATED NEUTRAL CONDUCTORS ARE REQUIRED FOR ALL 120V AND 277V BRANCH CIRCUITS.

MULTIWIRE BRANCH CIRCUITS WITH SHARED NEUTRAL CONDUCTORS ARE NOT PERMITTED. ROUTE NO MORE THAN (3)

BRANCH CIRCUIT HOMERUNS PER EACH CONDUIT RUN.

GENERAL LEGEND:

CODED NOTE - "1" INDICATES NOTE NUMBER

REVISION REFERENCE NUMBER

MECHANICAL EQUIPMENT IDENTIFIER

DETAIL REFERENCE - "1" INDICATES DETAIL NUMBER, "E0.1" INDICATES DRAWING NUMBER

COLUMN REFERENCE GRID

INDICATES EXISTING CONSTRUCTION WALL TYPE

INDICATES DEMOLITION WALL TYPE

INDICATES NEW CONSTRUCTION WALL TYPE

AC

GB1

E0.1

A

LIGHTING FIXTURES LEGEND

LED LIGHTING FIXTURE CONNECTED TO NORMAL CIRCUIT AS INDICATED - TYPE AS SPECIFIED IN SCHEDULE, "A" INDICATES TYPE, "3" INDICATES CIRCUIT NUMBER ASSIGNMENT, "a" INDICATES LOCAL SWITCHING CONTROL.

CONNECT FIXTURES SO THAT FIXTURES ARE CONTROLLED BY

LED LIGHTING FIXTURE CONNECTED TO EMERGENCY LIFE SAFETY CIRCUIT - TYPE AS SPECIFIED IN SCHEDULE, "A" INDICATES TYPE, "3" INDICATES CIRCUIT NUMBER ASSIGNMENT. CONNECT AHEAD OF LOCAL SWITCHING.

LED LIGHTING FIXTURE - CONNECTED TO EMERGENCY CRITICAL LIGHTING CIRCUIT - TYPE AS SPECIFIED IN SCHEDULE "A" INDICATES TYPE, "3" INDICATES CIRCUIT NUMBER ASSIGNMENT. CONNECT FIXTURES SO THAT FIXTURES ARE

CONTROLLED BY

LED LIGHTING FIXTURE - CONNECTED TO NORMAL CIRCUIT - TYPE AS SPECIFIED IN SCHEDULE. "A" INDICATES TYPE.

LED LIGHTING FIXTURE - CONNECTED TO EMERGENCY LIFE SAFETY LIGHTING CIRCUIT - TYPE AS SPECIFIED IN

SCHEDULE. "A" INDICATES TYPE. CONNECT AHEAD OF LOCAL SWITCHING.

LED LIGHTING FIXTURE - TYPE AS SPECIFIED IN SCHEDULE OR AS INDICATED ON PLANS

LED LIGHTING FIXTURE - CONNECTED TO EMERGENCY CRITICAL OR LIFE SAFETY LIGHTING CIRCUIT AS INDICATED

NL - NIGHT LIGHT

EXIT SIGN - CEILING OR WALL MOUNTED - TYPE AS SPECIFIED IN SCHEDULE OR AS INDICATED ON PLANS

A

A

C C

C C

3,a aS aS

A

3,a

A

A

S

59459

M.P. LONG

R

E

S

O F

I

R

G E

NO

I

S

P

E

N

E

D

ERT

L EA

E I N

G

R

T

S

TE

A

H

F OO

IO

FREDRICK, FREDRICK & HELLER

ENGINEERS, INC.

672 EAST ROYALTON ROAD

BROADVIEW HTS., OHIO 44147

TEL. (440) 546-9696

FAX: (440) 546-9699

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

1DESIGN AND CONSTRUCTION DOCUMENTS AS

INSTRUMENTS OF SERVICE ARE GIVEN IN

CONFIDENCE AND REMAIN THE PROPERTY OF

PERSPECTUS ARCHITECTURE. THE USE OF THIS

DESIGN AND THESE CONSTRUCTION

DOCUMENTS FOR PURPOSES OTHER THAN THE

SPECIFIC PROJECT NAMED HEREIN IS STRICTLY

PROHIBITED WITHOUT THE EXPRESSED

WRITTEN CONSENT OF PERSPECTUS

ARCHITECTURE. COPYRIGHT C 2019.

13212 Shaker Square Suite 204 Cleveland, Ohio 44120 P. 216.752.1800 F. 216.752.3833

18067

Z M y D o c u m e n ts \1

F F

H C

F R jd u a le .r v t

/2

/2

:4

:3

P

M

0-E1-1

10701 East Blvd. Cleveland, OH 44106

06/26/2020 MPL JRD

541-19-101Renovate Operating RoomsBID ISSUEELECTRICAL LEGEND AND GENERAL NOTES

Revisions: Date:

Bid Issue 06/26/2020

OCCUPANCY SENSOR PROGRAM SCHEDULE:

SENSOR TYPE

DUAL

TECHNOLOGY

ON CONTROL OFF CONTROL

MANUAL/SENSOR

TYPICAL

ROOM

TYPES

TYPICAL OFFICES

TOILET

OFF TIME

DELAY

AUTO OFF AFTER

MINUTES

MANUAL/SENSOR

AUTO OFF AFTER 5

MINUTES

DUAL

TECHNOLOGY

DUAL

TECHNOLOGY

MANUAL/SENSOR

AUTO OFF AFTER

MINUTES

CONFERENCE,

LARGER OFFICES

MANUAL

MANUAL

MANUAL

OCCUPANCY SENSOR SYSTEM SPECIFICATIONS

A. GENERAL SYSTEM SPECIFICATIONS

1. POWER SUPPLY, RELAY UNITS AND OCCUPANCY SENSOR SHALL BE FROM A SINGLE

MANUFACTURER.

2. CONTRACTOR MUST SUBMIT THE FOLLOWING AT A MINIMUM FOR SHOP DRAWING REVIEW.

a. COMPONENTS

POWER SUPPLY

RELAY UNITS

OCCUPANCY SENSOR

b. POWER SUPPLY CALCULATIONS

c. WIRING DIAGRAM

3. POWER SUPPLY, RELAY UNITS AND OCCUPANCY SENSOR SHALL ALL HAVE A FIVE YEAR

WARRANTY.

4. REFER TO SPECIFICATIONS SECTION 260923 FOR ADDITIONAL WORK REQUIREMENTS.

B. SENSOR

a. MINIMUM COVERAGE AREA OF 500SQFT WITH ADJUSTABLE SENSITIVITY

b. PROGRAMMABLE AUTO-ON/MANUAL-ON

c. 360 DEGREE COVERAGE OR 180 DEGREE COVERAGE AS NECESSARY SUCH THAT

THE ENTIRE ROOM IS COVERED WITHOUT NUISANCE TRIPS (AWAY FROM GLASS

WALLS, DOORS TO HALLWAYS, ETC.)

d. ADJUSTABLE TIME DELAY

C. POWER SUPPLY SPECIFICATIONS

1. INPUT

a. VOLTAGE: 277/120V-1ɸ

2. OUTPUT

a. VOLTAGE: 24VDC

b. PROVIDE POWER SUPPLY OR SUPPLIES AS NECESSARY FOR ALL CONNECTED

ACCESSORIES (SENSORS, RELAYS, ETC.)

3. SHALL BE UL LISTED

D. RELAY UNIT SPECIFICATIONS

1. INPUT

a. VOLTAGE: 24VDC

2. FORM C RELAY (ONE NORMALLY CLOSED, ONE NORMALLY OPEN CONTACT)

3. NORMALLY OPEN (N.O.) OR NORMALLY CLOSED (N.C.) SINGLE CONTACT RELAY

4. SHALL BE UL LISTED

BALLAST BALLAST MOTOR

5A @ 120VAC

3A @ 277VAC

.25HP @ 120VAC

.5HP @ 277VAC

MINIMUM RATINGS

3A @ 120VAC

2.5A @ 277VAC

BALLAST BALLAST MOTOR

20A @ 120VAC

20A @ 277VAC

1HP @ 120VAC

MINIMUM RATINGS

16A @ 277VAC

POWER

PACK

277VAC:24VDC

CONTROL OUTPUT

COMMON

+24VDC

WHT

BLK

R E

D

B L K

B L U

RED

RED

OS

NEUTRAL

HOT

MOUNT ABOVE

FINISHED CEILING

A

L

O

D

SINGLE POLE WALL SWITCH MOUNTED AT DOORWAY

(PROVIDE ADDITIONAL CONDUCTORS AS

REQUIRED FOR DIMMER SWITCH)

ANY 24VDC SENSOR-

CEILING MOUNTED

LOW VOLTAGE "LV" CABLING PER

MANUFACTURERS WIRING DIAGRAMS.

INSTALLED IN 3/4"C.

LIGHTING FIXTURE APPEARANCE SCHEDULE

TYPE A1, A2 TYPE B2, C1 TYPE D,F

TYPE E

TYPE G

TYPE B1, C2

TYPE EXIT

S

59459

M.P. LONG

R

E

S

O F

I

R

G E

NO

I

S

P

E

N

E

D

ERT

L EA

E I N

G

R

T

S

TE

A

H

F OO

IO

FREDRICK, FREDRICK & HELLER

ENGINEERS, INC.

672 EAST ROYALTON ROAD

BROADVIEW HTS., OHIO 44147

TEL. (440) 546-9696

FAX: (440) 546-9699

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

1DESIGN AND CONSTRUCTION DOCUMENTS AS

INSTRUMENTS OF SERVICE ARE GIVEN IN

CONFIDENCE AND REMAIN THE PROPERTY OF

PERSPECTUS ARCHITECTURE. THE USE OF THIS

DESIGN AND THESE CONSTRUCTION

DOCUMENTS FOR PURPOSES OTHER THAN THE

SPECIFIC PROJECT NAMED HEREIN IS STRICTLY

PROHIBITED WITHOUT THE EXPRESSED

WRITTEN CONSENT OF PERSPECTUS

ARCHITECTURE. COPYRIGHT C 2019.

13212 Shaker Square Suite 204 Cleveland, Ohio 44120 P. 216.752.1800 F. 216.752.3833

18067

Z M y D o c u m e n ts \1

F F

H C

F R jd u a le .r v t

/2

/2

:4

:4

P

M

0-E1-2

10701 East Blvd. Cleveland, OH 44106

06/26/2020 MPL JRD

541-19-101Renovate Operating RoomsBID ISSUELIGHTING FIXTURE SCHEDULE AND DETAILS

LIGHTING FIXTURE SCHEDULE

TYPE FIXTURE DESCRIPTION MOUNTING MAX HEIGHT

FIXTURE DRIVER(S)

TYPE COLOR TEMP

LUMEN

MAINTANCE

RATING

EFFICANCY LUMEN WATTAGE VOLTAGE TYPE QUANTITY

A1 2' X 4' SURGICAL LED ASYMMETRIC/SYMMETRIC LIGHTING FIXTURE,

FULLY SEALED, HOLE-FREE HOUSING, WHITE ANTI-MICROBIAL

PAINT FINISH, SILICONE-GASKETED BETWEEN HOUSING AND LENS

FRAME AND LENS, DOOR WITH CONTINUOUS HINGE AND STAINLESS

STEEL CAPTIVE FASTENERS, WET LOCATION LISTED, IP65 RATED,

MEETS MIL-STD 461F. 90 CRI

LAY-IN GRID 0' - 3 1/4" LED 5000 K

L70@80,000 hrs

135 LPW 13550 134 W 277 V

100% - 1%V Dimming

A2 SAME AS TYPE 'A1' WITH EMERGENCY BATTERY BACKUP WITH

'REMOTE TEST SWITCH. DISABLE AUDIO ALARM FOR BATTERY

BACK UP.

LAY-IN GRID 0' - 3 1/4" LED 5000 K

L70@80,000 hrs

135 LPW 13550 134 W 277 V

100% - 1%V Dimming

B1 2' X 4', DIRECT/INDIRECT, RIBBED FROSTED ARCYLIC CENTER LENS,

HIGH REFLECTANCE WHITE POWDER COATED REFLECTORS, STEEL

HOUSING WITH HINGED DOOR, FUSING.

LAY-IN GRID 0' - 3 1/4" LED 4000 K

L70@60,000 hrs

113.8 LPW 4043 29 W 277 V

100% - 1%V Dimming

B2 2' X 4' FULLY LUMIOUS DEEP RECESSED TROFFER, PRISMATIC

ACRYLIC LENS, HEAVY GAUGE STEEL HOUSING AND DOOR FRAME,

FUSING

LAY-IN GRID 0' - 3 1/4" LED 4000 K

L70@60,000 hrs

113.8 LPW 4269 35 W 277 V

100% - 1%V Dimming

C1 2' X 2' FULLY LUMIOUS DEEP RECESSED TROFFER, PRISMATIC

ACRYLIC LENS, HEAVY GAUGE STEEL HOUSING AND DOOR FRAME,

FUSING. POSITIVE CAM ACTION STEEL LATCHES WITH BAKED

WHITE ENAMEL FINISH.

LAY-IN GRID 0' - 3 1/4" LED 4000 K

L80@60,000 hrs

106.9 LPW 2400 19 W 277 V

100% - 1%V Dimming

C2 2' X 4', DIRECT/INDIRECT, RIBBED FROSTED ARCYLIC CENTER LENS,

HIGH REFLECTANCE WHITE POWDER COATED REFLECTORS, STEEL

HOUSING WITH HINGED DOOR, FUSING.

LAY-IN GRID 0' - 3 1/4" LED 4000 K

L70@60,000 hrs

102.27 LPW 2400 19 W 277 V

100% - 1%V Dimming

D 6" DIA RECESSED DOWNLIGHT, SEMI-SPECULAR CLEAR REFLECTOR

AND WHITE POLYMER TRIM, LED BOARD AND DRIVER ACCESSIBLE

FROM BELOW, CONVEX TRANSITIONAL LENS.

LAY-IN GRID 0' - 7" LED 4000 K

L70@ 50,000 hrs

70.4 LPW 1500 23 W 277 V

100% - 1%V Dimming

E 5-3/8"W X 4'L LED STRIP FIXTURE, COLD-ROLLED STEEL HOUSING,

HIGH GLOSS BACKED WHITE ENAMEL FINISH, FLAT DIFFUSE LENS.

LAY-IN GRID 0' - 3 1/2" LED 4000 K

L70@50,000hr s

105.5 LPW 4269 0 W 277 V

100% - 1%V Dimming

EXIT LED TYPE, AC ONLY, WALL OR CEILNG MOUNT AS INDICATED ON

DRAWINGS, ALUMINUM CANOPY WITH WHITE FINISH, HIGH IMPACT

CLEAR POLYCARBONATE HOUSING, RED LETTERS WITH WHITE

FACE. REFER TO LIGHTING PLANS FOR CUSTOM CONFIGURATION

OF CHEVRON DIRECTIONAL ARROWS. UL 924 LISTED. CONNECT TO

UNSWITCHED EMERGENCY LIFE SAFETY CIRCUIT.

LED 4 W 277 V NA 1

F 6" DIA RECESSED SURGICAL DOWNLIGHT, LOWER REFLECTOR

WITH A LENSED UPPER OPTICAL CHAMBER, STEEL TRIM RING,

POWDER COATED PAINTED ANTI-MICROBIAL WHITE WITH

GAKETING LENS TO TRIM RING. LED BOARD AND RIVER

ACCESSIBLE FROM BELOW. UL LISTED FOR PROTECTED WET

LOCATIONS.

GYPSUM

CEILING

0' - 7" LED 5000 K

L70@ 50,000 hrs

105.5 LPW 2000 21 W 277 V

100% - 1%V Dimming

G 5.2"W X 10.37"H LED ENCLOSED AND GASKETED BRACKET

MOUNTED FIXTURE WITH FROSTED GLASS GLOBE WITH

REMOVABLE ALUMINUM CAGE AND DIE CAST ALUMINUM HOUSING.

REFER TO EXTERIOR EQUIPMENT LIGHT/RECEPTACLE DETAIL FOR

ADDITIONAL INFORMATION.

UNISTRUT

MOUNTED

0' - 10 3/8" LED 4000 K

L70@50,000hr s

85 LPW 17 W NA 1

SL SURGICAL EXAM LIGHT FIXTURE - OWNER FURNISHED./INSTALLED

RADIAL ARM MOUNTED LAMPHEADS, CEILING MOUNTED. PROVIDE

SUPPORT SYSTEM AS REQUIRED BY MANUFACTURER AND

ROUGH-IN FOR WALL MOUNTED LIGHT CONTROLLER. CONTRACTOR

SHALL COORDINATE MANUFACTURER'S INSTALLATION

REQUIREMENTS WITH EQUIPMENT VENDOR

LAY-IN GRID 0' - 0" LED 5000 K - - 16000 160 W 120 V - -

NOT TO SCALE

OCCUPANCY SENSOR WITH SINGLE SWITCHING

TYPICAL WIRING DIAGRAM 1

120V1450

WALL/CEILIN

G

N/A N/A N/A N/A N/A

DNDN

9A 12A 25D 27b

A1

ZZ

YY

XX

UU

RR

B

D

TT

VV

27m27n27p 27r 27s 27t27w 2 35.5532 36.5

E

38.6

34.1

J

K

L

11 13a 14 15a 16a 18a 21 23d 28a 31 414038

M

19b

K1

H1

MCC-E1MCC-N1 XX

REFER TO DRAWINGS 3-E4-1 AND

3-E4-2 FOR PROJECT SCOPE

NEW ELECTRICAL ROOM

(SECOND FLOOR)

ETR ELECTRICAL ROOM

(SECOND FLOOR)

EXISTING

ROTOMATS

EXISTING

ROTOMATS

EXISTING

ROTOMATS

EXISTING

ROTOMATS

EXISTING

ROTOMATS

EXISTING

ROTOMATS

XXXXX

X

SUBSTATION L1

X X

X

X

X

X X

WORK ABOVE CEILING SHALL BE

COMPLETED DURING THE

WEEKENDS. REFER TO

ARCHITECTURAL DRAWINGS

FOR ADDITIONAL WORK

REQUIREMENTS. COORDINATE

SCHEDULING WITH VA COR.

X

DPHL11CR1

UP TO SECOND FLOOR.

REFER TO DRAWING 0-

E1-4 FOR CONTINUATION

EMS

Patient

Clothing

1B431

VSO Office

1B414

Hall

1B412

VSO Office

1B415 VSO Office

1B413

Escort Services

1B411

Patient Alcove

1B410

Tri-C Veterans

Edu.

Connection

Center

1B420

Surgical Service Office

1B462

EMS

1B464

Hall

1B400EMillion Veteran

Program-MVP

1B461

Tele-Health

1B472

Surgical Service Office

1B473

Neurology Office

1B463

Tele-Health

1B475

EEG Lab

1B466 E.C.

1B465

PIV

1B467 Surgical Service Office

1B477

Electrical

1B497

IRM

1B496 Surgical Service Office

1B476

Eng Closet

1B495

Surgical Service Office

1B474

Office

1B471

Hall

1B400C

Stair #8

1C401

Men's Toil.

1B327

Women's Toil.

1B326

Mainstreet

1B400B

Mainstreet

1B400A

Stair #11

1B400C

Office

1E234

Office

1E237

Office

1E231

Office

1E235

Office

1E239 Secretary

1E230

Office

1E215

CL

1E214

Office

1E233

Office Services

1E213

Office

1E232

Stair #4

1E201

Office

1E222

Office

1E221

Office Services

1E212

ACP-

Details

PAT

Funds

1A219B

ACP

Travel

1E302C

ACP

Travel

1A219C Reception

1A219A

PCAS

Photo ID

1A219D

Stor.

1B101

Elect.

1B103

MCCR I.P.

Biller

1A219F

MCCR

U.R. Nurse

1A219I

MCCR Bill Rep.

1A219G

ACP

Eligibility

1A219E

ACP

Means Clerk

1A219J

ACP

Means Clerk

1B311K

Hall

1A219

Corridor

1B300A

Laundry

1B113

ACP Lead

1B320AACP Lead

1B320C

ACP Lead

1B320D

ACP Lead

1B320E

PCAS Bed Control

1A320

PTC Prog.

Supp.

Assist

1B320L

Hall

1B300C

PTC Day Ward Supr

1B323

PTC Day Ward Supr

1B325

PTC

Work/File

1B324

PTC

Office-Chief

1B322

Closet

1B321A

PCAS

Conf Rm

1B321

Cubicle

1B320K

Cubicle

1B320J

ACP

Sched.

1B320H

ACP

Sched.

1B320G

Office

1B267

Waiting Room

1B220 Entry

1B102L

Changing Rm.

1B102B

Comm.

1B100

Kitchen

1C228

Office

1C226

Section Chief:

Otorhinolaryngology

1C227

Hall

1C200B

Court Liason

1C225

Social Work Office

1C224

Clinical Social

Worker

1C223 Vacant

1C222

Vascular Surgeon

1C221

Office

1C220

Stair #9

1C216

Waiting/Clerical

1C215

Vacant

1C214

Section Chief:

Orthopedics

1C213

Vascular Surgeon

1C211 Section Chief:

Vascular Surgeon

1C212

VAST-D

Study Office

1C210

Hall

1C200A

Psych Testing

1B268

Elec.

1C211A

Servery

1C411

Dining

1C410

Corridor

1C400

Electrical

1C418

Vending

1C419

Corridor

1C400D

Storage

1C420

Chancel

1E384C

Chapel

1E384

Sacristy/Storage/AV Equip

1E385

Stair #3

1E301

Hemo/Oncology

1E344

Elec

1E343

Storage

1E384B

Muslim Prayer Room

1E382

Worship Vestibule

1E383

Office

1E384A

Conference Room

1E335

A159 EC/Data

1E334

Office Admin Asst

1E331

Deputy Chief of

Staff

1E332

Deputy Chief of

Staff

1E333

Office

1E312

Office Chief

1E313

Storage

1E311

Rec/Wtg

1E310

Hemo/Oncology

1E349

Swing Space

1E330

Hematology Office

1E322

Office Qual Schol

1E324

Office Qual Schol

1E326

Hall

1E320B

Elect.

1E328A

Hall

1E320A

Rec/Wtg

1E320

Office Training

1E321

Office Qual Schol

1E323

Office Qual Schol

1E325

Blessed Sacrement

Chapel

1E381

Corridor

1E380

Mainstreet

1F300

Chaplain Office

1F313

Emergency Management

Storage

1E353

Elevator Lobby

1C400A

Mechanical

1C300C

Lobby

1C300A

Corridor

1C300

Office

1E421

Office

1E422

Office

1E411

Electrical Closet

1E401

Cubicle

1E423L

Cubicle

1E423M

Cubicle

1E423N

Cubicle

1E423O

Nurse Station

1B102F

Clean Utility

1B102E Office

1B102K

Seclusion

1B102I

Toilet

1B102J

Ante Room

1B102M

Corridor

1B102 Holding

1B102G

Soiled Utility

1B102D

Seclusion

1B102H

Toilet

1B102GA

Interview

1B102A

Consult/ Exam

1B102C

F. Lockers

M. Lockers

VSO Office

1B417

VSO Office

1B416

Corridor

1B300B

EMS

Supervisors

2nd + 3rd Shift

1D394

Entry 3

1D400C

Part. Stor

1D370G

Storage

1D393

Entry 2

1D400B

Part. Stor

1D370F

EMS

1D392

Entry 1

1D400A

Kitchen

1D391

Stair #5

1D301

Rec Hall 1

1D370A

Rec Hall 4

1D370B

Rec Hall 5

1D370C

Rec Hall 2

1D370D

Rec Hall 3

1D370E

Corridor

1D400

Corridor

1D350

Corridor

1D340A

Hall

1D340

Hemo Oncology

1E350

Pain Mgmt.

Office

1E340A

Pain Mgmt.

Office

1E340B

Rec Hall Storage

1E351

Hemo/Oncology

1E348

Pain Mgmt.

Office

1E347

Closet

1E352A

Conference Room

1E352

Men's Rest.

1D331

Women's Rest.

1D330

Retail Storage

1D320

Counting

1D311B

Retail Office Chief

1D311C

Retail Office Admin Asst

1D311A

Hall

1D311

Secure Sales

1D310A

Retail Sales

1D310

Mainstreet

1E300

Hall

1E342

Pain Mgmt.

Office

1E338

Hemo/Oncology Office

1E337

Pain Mgmt.

Office

1E339

Pain Mgmt.

Office

1E341

Pain Mgmt.

Work Room

1E346

Phys.

Office 18

1D421

Men

1D401

Women

1D402 Conference

1D429

Phys.

Office 11

1D428

Phys.

Office 12

1D427

Phys.

Office 13

1D426

Phys.

Office 15

1D424

Phys.

Office 16

1D423

Phys.

Office 17

1D422

Stair #2

A138

Office

1F323

Office

1F324

Cares Nutrition

1F326

Corridor

1F325

Corridor

1F321

Office

1F319

Office

1F315

Break Room

1F317A

Corridor

1F317

Admin.

Manager

1F318

Office

1F316

Copy Work

1F314

Radio Room

1D390 Storage Room

1D371

Corridor

1C400C

Service Lobby

1C400B

Cart Wash

1C431

Elect.

1C432

Elect.

1C420A

Tray Make-Up

1C430

Corridor

1B200L

PTC Prog.

Supp.

Assist

1B320M

PTC Prog.

Supp.

Assist

1B320N

PTC Prog.

Supp.

Assist

1B320O

ACP Lead

1B320B

ACP Lead

1B320F

Cubicle

1B320I

Corridor

1E400

Corridor

1E400G

Office

1E211

Loan

1F433

Public Access

Computers

1F432

Circulation

1F420

Basic Reference

1F421

Library Seating

1F440

Corridor

1F400

Vacant

1F401

Chaplain Office

1F402

Public Aff.

Office

1F403

Librarian

1F404

Medical Librarian

1F405

Corridor

1F406

Workstations

1F410 Chief Office

1F412

AV

Storage

1F411

AV Room

1F435

AV Room

1F436 AV Room

1F437

Work Room

1F407

Office Interns

1E287

Restroom

1E288

Staff Assist. Dir.

Office

1E289

Office

1E290

Copy/ Work

1E291

Open Office

1E292

MCCR

U.R. Nurse

1A219H

Elect.

1D400D

Closet

1E352B

Phys.

Office 14

1D425

Closet

1B324A

ACP

Travel

1B311A

Reception

1E220

Corridor

1E200A

Office

1E236

Corridor

1E200C

Corridor

1E200B

Corridor

1F310

Corridor

1F320

Cl.

1ZZ027

Office

1E238

Corridor

1D410

Electrical

1D467

OFFICE

1-C335

EXAM 6

1-C332

EXAM 5

1-C331

SOILED

HOLDING

1-C333

EXAM 4

1-C327

EXAM 2

1-C325

WAITING

1-C324

EXAM 1

1-C326

EXAM 3

1-C328

PACT

TEAM

ROOM

1-C322

PACT

TEAM

ROOM

1-C334

CORRIDOR

1-C330

CORRIDOR

1-C330A

CORRIDOR

1-C320A

COORDINATOR

OFFICE

1-C321

RECEPTION

1-C323

CORRIDOR

1-B300B

CLEAN

HOLDING

1-C329

ELECT.

1-C343

HSKP

1-351

CORRIDOR

1-C320

EQUIP./SPEC.

PROCESSING

1-C365

EXAM 1

1-C362

SOILED

HOLDING

1-C371

CLEAN

HOLDING

1-C366

BLOOD

DRAW

1-C364

WAITING

1-C370

EXAM 4

1-C355

EXAM 2

1-C359

EXAM 3

1-C357

EXAM 6

1-C361

EXAM 7

1-C358

EXAM 8

1-C356

EXAM 9

1-C354

TLT.

1-C363

CORRIDOR

1-C370A

WORKROOM

1-C382

EXAM 5

1-C353

EXAM 10

1-C352

RECEPT.

1-C372

CUBICLE

SPACE

1-C380

FILES

1-C381

KITCHEN

1-C383

CORRIDOR

1-C360

CORRIDOR

1-C350

CORRIDOR

1-C370B

WOMENS

TLT.

1-C344

MENS

TLT.

1-C341PAT. REPS

1-C345

PAT. REPS

1-C346

PAT. REPS

1-C347

PAT. REPS

1-C348

P.E.R.C.

1-C349

UNISEX

TLT.

1-C342

REPS

WAITING

1-C300E

Chaplain Office

1F312

Chaplain Office

1F322

Office/Exam Rm.

1D121

Office/Exam Rm.

1D120

Office/Exam Rm.

1D119

Stair 13

Toilet

1D124

Office/Exam Rm.

1D115

Office/Exam Rm.

1D114

Tl.

1D112

Office/Exam Rm.

1D132

Office/Exam Rm.

1D131

Clean Linen

1D125

Office/Exam Rm.

1D126

Office/Exam Rm.

1D127

Office/Exam Rm.

1D128

Office/Exam Rm.

1D129

Office/Exam Rm.

1D130

Vascular Lab

1D139

Office/Exam Rm.

1D140

Office

1D138

Office/Exam Rm.

1D141

Toilet Room

1D210 Elect.

1D211 Clean

1D215

Office/Exam Rm.

1D137 Vascular Lab

1D135

Ems

1D136

Tl, F

1D219

Tl, M

1D220

Office

1D218

Office/Exam Rm.

1D217

Geri./ID Office/Exam

Rm.

1D216

Geri./ID Office/Exam

Rm.

1D226

Geri./ID Office/Exam

Rm.

1D225

Office/Exam Rm.

1D214

Geri./ID Office/Exam

Rm.

1D213

Office/Exam Rm.

1D212

Office/Exam Rm.

1D227

Toilet

1D229 Office/Exam Rm.

1D228

Office/Exam Rm.

1D224

Pain Mgmt.

Office/Exam Rm.

1D223

Office/Exam Rm.

1D231

Office/Exam Rm.

1D232

Pain Mgmt.

Office/Exam Rm.

1D233 Conference

Rm

1D230

Lounge

TL,F &

Lockers

Tl, M & Lockers

Ems

Gas-soiled

Gas-clean

Elevator Equipment

Storage

124 Ems

Preperation

Sterilization

Office

104B

Office

104A

Conference Room

HAC

Clean Receiving

Storage

Computer Room

Storage

1D133A

Sprinkler Shut-off

129E

Firm A Waiting

Rm.

1D235

Reception

1D234A Work Room

1D234B

Sterile Storage

Nuses Station

1D222

Equip Access

115A Cart Wash

Switchgear

Mechanical Room

ML

Office/Exam Rm.

1D113 Office/Exam

Rm.

1D116Office/Exam Rm.

1D117

Conference

1D118

Office/Exam Rm.

1D122

Firm B Waiting Room

1D110 Director's Office

S129DOffice

S129A Office

S129B Office

S129C

Office

1D133B

Reception

1D111A

Work Room

1D111B

Holding

1D133

Corridor

C100C

Cart Driving

Nurses Station

1D134

Stair

2S7

Dispatch Cart Area

Shell Space

C102

Corridor

1D100C

Corridor

1D100B

Corridor

1D100E

Corridor

1D200B

Corridor

1D100H

Corridor

1D200A

Corridor

1D200D

Corridor

1D200G

Corridor

1D200C

Corridor

1D200E

Corridor

1D100G

Corridor

C100B

Entry

117A

Soiled/ Recieving

And Decontamination

Deionizer

Corridor

C100D

Mechanical

1D123

Corridor

C100A

Room

S129E

Corridor

1D100F

Corridor

1D100D

Corridor

1D200F

Office

1B266

Office

1B263

Office

1B262

Office

1B260

Office

1B258

Office

1B257

Office

1B255

Area-Well

1B253

Office

1B265A

Office

1B265

Group Room

1B264

Office

1B261

Office

1B259 Detox

1B226

Detox Office/Exam

1B224A

Reception

1B222

Detox Office

1B224

Methadone

1B223

Urine Testing

1B225

JC

1B227

Intake Office

1B228

Group Room

1B244

Office

1B245A

Office

1B245

Office

1B256

Office

1B254

Office

1B252

Office

1B250

Office

1B249

Office

1B248

Exam

1B247

Office

1B246

Office

1B242

Meds Storage

1B243

Staff Tlt Men

1B230

Staff Tlt Women

1B231

Office

1B234

Office

1B241

Office

1B240 Office

1B236

Office

1B237

Office

1B235

Office

1B233

Pump Room

1B229

Stair

1B311

Detox Shower

1B226A

S

59459

M.P. LONG

R

E

S

O F

I

R

G E

NO

I

S

P

E

N

E

D

ERT

L EA

E I N

G

R

T

S

TE

A

H

F OO

IO

FREDRICK, FREDRICK & HELLER

ENGINEERS, INC.

672 EAST ROYALTON ROAD

BROADVIEW HTS., OHIO 44147

TEL. (440) 546-9696

FAX: (440) 546-9699

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

1DESIGN AND CONSTRUCTION DOCUMENTS AS

INSTRUMENTS OF SERVICE ARE GIVEN IN

CONFIDENCE AND REMAIN THE PROPERTY OF

PERSPECTUS ARCHITECTURE. THE USE OF THIS

DESIGN AND THESE CONSTRUCTION

DOCUMENTS FOR PURPOSES OTHER THAN THE

SPECIFIC PROJECT NAMED HEREIN IS STRICTLY

PROHIBITED WITHOUT THE EXPRESSED

WRITTEN CONSENT OF PERSPECTUS

ARCHITECTURE. COPYRIGHT C 2019.

13212 Shaker Square Suite 204 Cleveland, Ohio 44120 P. 216.752.1800 F. 216.752.3833

18067

Z M y D o c u m e n ts \1

F F

H C

F R jd u a le .r v t

/2

/2

:5

:5

P

M

0-E1-3

10701 East Blvd. Cleveland, OH 44106

06/26/2020 MPL JRD

541-19-101Renovate Operating RoomsBID ISSUEPARTIAL FIRST FLOOR ELECTRICAL KEY PLAN

0' 8' 16' 32' 64'0' 8' 16' 32' 64'0' 8' 16' 32' 64'0' 8' 16' 32' 64'0' 8' 16' 32' 64'

1/16" = 1'-0"

PARTIAL FIRST FLOOR ELECTRICAL KEY PLAN 1N

PATHWAY SHOP DRAWINGS REQUIREMENTS

APPROXIMATE ROUTING SHOWN ON THESE DRAWINGS FOR ELECTRICAL FEEDERS ARE ONLY TO INDICATE GENERAL SCOPE OF WORK. CONTRACTOR MUST FIELD VERIFY ACTUAL ROUTING AND SUBMIT "PATHWAY SHOP DRAWING" TO VA COR FOR APPROVAL AND COORDINATION. DRAWING SHALL BE MINIMUM 1/16" = 1'-0" SCALE AND SHALL INDICATE, BUT IS NOT LIMITED TO, PROPOSED ROUTE, PULLBOXES, PENETRATIONS THROUGH FLOORS AND LIFE SAFETY BARRIERS (SMOKE AND FIRE), ETC. WHERE ROUTING IS ABOVE FINISHED CEILINGS IN OCCUPIED

AREAS, INDICATE APPROXIMATE LENGTH OF TIME AND EXTENT OF WORK REQUIRED.

15C 16C 20A 24C 25B 26B 28B27d

C2

A1

ZZ

YY

XX

UU

RR

ss

TT

WW

VV

14B 27m 27s 27t27w 27x 532

E

G1

C1

13a 14 15a 16a 17a 18a 21 23d 24b 25a 28 30a19c

LL22CR2

HL22CR1

HL22CR2

T-LL21

HL21

LL21

HL21CR1

LL21CR1

LL21CR2

HL21CR2

T-LL21CR1

LL21CR2

LL22CR1

LL23CR1

NEW REMOTE MASTER

ANNUCIATOR PANEL FOR

ISOLATE POWER PANELS. REFER

TO DRAWING 2-E3-2 FOR

ADDITIONAL INFORMATION.

OUTLINE OF EXISTING

ELECTRICAL ROOM 3-B162b

ON THIRD FLOOR.

Phase 2

Phase 2A Phase 2B

Phase 3

Phase 3B Phase 3C

P h a s e

A

P h a s e

D

Phase 1

DOWN TO FIRST FLOOR.

REFER TO DRAWING 0-

E1-3 FOR CONTINUATION.

TYP

UP TO 3RD FLOOR ELECT ROOM

THRU EXISTING PATHWAY. REFER

TO DRAWING 0-E1-5 FOR

CONTINUATION

Office

2D285

Office

2D284

Office

2D283

Anesthesia Workroom

2C218

Ortho OR

(OR-10)

2C217

General

OR

(OR-09)

2C216

Ortho OR

(OR-08)

2C215

Laboratory, Frozen Section

2C214

Ortho Equipment

2C215A

Electrical Room

2C213

Semi-Restricted

2C200F

Bed Holding

2C200M Scrub

2C200L

Bed Holding

2C200K

Scrub

2C200J

Bed Holding

2C200H

Scrub

2C200G

General

OR (OR-6)

2C212

Bed Holding

2C200E

Scrub

2C200D

Bed Holding

2C200C

General

OR (OR-5)

2C210

Scrub

2C200B

Anesthesia Office

2D282

Anesthesia Storage

2C222

Medication Prep

Room

2C219A

Soiled Holding

2D281

Cart Holding

2C219

Clean Corridor

2C200P

Alcove

2C200Q

Alcove

2C200R

Robotic

OR (OR-5)

2C114

Immediate Use

Sterilization Room

2C123

OI&T

2C122

Electrical Room

2C115

Scrub

2C100D

Bed Holding

2C2100C

Gas Room

2C211

EMS

2C110

Anesthesia Storage

2C111

Semi-Restricted

2C100B

Robotic Equipment

Storage

2C213

Equipment Storage

2C112

Semi-Restricted

2C100A

Semi-Restricted

2C200A

EMS

Closet

2D280

Alcove

2C100N

Alcove

2C100M Alcove

2C100K

Cardiac Equipment

2C127

Cardiac

OR (OR-1)

2C129

Cardiac

OR (OR-2)

2C126

Cardiac Pump Room

2C128

Scrub

2C100Q

Bed Holding

2C100P

Semi-Restricted

2C100E

Scrub

2C100U

Bed Holding

2C100T

Implant Storage

2D252

Mens Lockers

2D251A

Corridor

2D250 Clean

Corridor

2C100J

Clean Corridor

2C100H

Vestibule

2C200N

Male Lockers

2D192C

Staff Toilet/

Shower

2D192D

Staff Toilet/

Shower

2D192B

Female Lockers

2D192A

Pharmacy

2D193

Lactation

2D194

Public Toilet

2D195

Family Lounge

2D196

Corridor

2D100M

Communication (Monitor)

Room

2D197

Dietician Office

2D198

Procedure

2C231

Procedure

2C232

Passage

2C230

Sub-Sterile

2C235

Procedure

2C233

Stair #9

2C202

PACU EMS

2C234

PACU

Cubicle 1

2C237A

PACU

Cubicle 2

2C237B

PACU

Cubicle 3

2C237C

PACU

Cubicle 4

2C237D

PACU

Cubicle 5

2C237E

PACU

Cubicle 6

2C237F

HAC

2C224

Office

2D132

Consult

2D264

Foyer

2D255E

Nurse Manager

2D134

Soiled Utility Room

2D124

On-call

2D265

On-call

2D266

Vest.

2D258

Vest.

2D256

Anteroom

2D127A

Shower

2D255D

Shower

2D257D

Men Tlt.

2D255C

Men Lockers

2D255A

Corridor

2D275

Alcove

2D250C

Women Lockers

2D257A

Work

2D260A

Work

2D260B

Work

2D260C

Work

2D260D

Work

2D260E

Patient Room #12

2D122

Locker Room

2D131

EMS Closet

2D110

Staff Toilet

2D133

Patient Room #1

2D125

Corridor

2D130B

Staff Lounge

2D135

Patient Room #3

(Isolation)

2D127B

Toilet

2D127C

Women Tlt.

2D257C Women Tlt.

2D257B

Men Tlt.

2D255B

Work

2D260F

Tlt / Shower

2D265A

Nurse Mgr.

2D262

Surgery Waiting

2D270

Alcove

2D260H

Administrative Center

2D118

Patient Room #2

2D126

Patient Room #4

2D111

Patient Room #5

2D112

Nourishment

2D130A

Corridor

2D130

Alcove

2D275B

Alcove

2D275C

Corridor

2D275A

Alcove

2D260G

Office

2D261C

Lounge / Dictation

2D251

Alcove

2D251A

S

59459

M.P. LONG

R

E

S

O F

I

R

G E

NO

I

S

P

E

N

E

D

ERT

L EA

E I N

G

R

T

S

TE

A

H

F OO

IO

FREDRICK, FREDRICK & HELLER

ENGINEERS, INC.

672 EAST ROYALTON ROAD

BROADVIEW HTS., OHIO 44147

TEL. (440) 546-9696

FAX: (440) 546-9699

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

1DESIGN AND CONSTRUCTION DOCUMENTS AS

INSTRUMENTS OF SERVICE ARE GIVEN IN

CONFIDENCE AND REMAIN THE PROPERTY OF

PERSPECTUS ARCHITECTURE. THE USE OF THIS

DESIGN AND THESE CONSTRUCTION

DOCUMENTS FOR PURPOSES OTHER THAN THE

SPECIFIC PROJECT NAMED HEREIN IS STRICTLY

PROHIBITED WITHOUT THE EXPRESSED

WRITTEN CONSENT OF PERSPECTUS

ARCHITECTURE. COPYRIGHT C 2019.

13212 Shaker Square Suite 204 Cleveland, Ohio 44120 P. 216.752.1800 F. 216.752.3833

18067

Z M y D o c u m e n ts \1

F F

H C

F R jd u a le .r v t

/2

/2

:4

:2

P

M

0-E1-4

10701 East Blvd. Cleveland, OH 44106

06/26/2020 MPL JRD

541-19-101Renovate Operating RoomsBID ISSUEPARTIAL SECOND FLOOR ELECTRICAL KEY

PLAN

0' 4' 8' 16' 32'0' 4' 8' 16' 32'0' 4' 8' 16' 32'0' 4' 8' 16' 32'0' 4' 8' 16' 32'

1/8" = 1'-0"

PARTIAL SECOND FLOOR ELECTRICAL KEY PLAN 1

N

CODED NOTES

NEW ELECTRICAL ROOM AND ELECTRICAL DISTRIBUTION EQUIPMENT - REFER TO POWER DISTRIBUTION ONE

LINE DIAGRAM FOR ADDITIONAL INFORMATION AND WORK REQUIREMENTS.

PROVIDE ROOM COORDINATION PLAN ALONG WITH POWER DISTRIBUTION SUBMITTAL THAT INDICATES ALL NEW AND EXISTING EQUIPMENT AND SUPPORTS WITH FIELD MEASURE DIMENSIONS OF ROOM, EXISTING

EQUIPMENT, NEW EQUIPMENT AND DIMENSIONS TO CONFIRM NEC WORK CLEARANCES ARE MET.

PROVIDE NEC COMPLIMENT PULLBOXES ALONG NEW FEEDER RUNS ON 100' CENTERS OR AFTER (4) 90 DEGREE HANDS. FIELD VERIFY EXACT LOCATIONS OF ALL PULL BOXES AND COORDINATE WITH SYSTEMS

ABOVE FINISHED CEILING. TYPICAL FOR ALL FEEDER RUNS.

PATHWAY SHOP DRAWINGS REQUIREMENTS

APPROXIMATE ROUTING SHOWN ON THESE DRAWINGS FOR ELECTRICAL FEEDERS ARE ONLY TO INDICATE GENERAL SCOPE OF WORK. CONTRACTOR MUST FIELD VERIFY ACTUAL ROUTING AND SUBMIT "PATHWAY SHOP DRAWING" TO VA COR FOR APPROVAL AND COORDINATION. DRAWING SHALL BE MINIMUM 1/16" = 1'-0" SCALE AND SHALL INDICATE, BUT IS NOT LIMITED TO, PROPOSED ROUTE, PULLBOXES, PENETRATIONS THROUGH FLOORS AND LIFE SAFETY BARRIERS (SMOKE AND FIRE), ETC. WHERE ROUTING IS ABOVE FINISHED CEILINGS IN OCCUPIED

AREAS, INDICATE APPROXIMATE LENGTH OF TIME AND EXTENT OF WORK REQUIRED.

DN

9A 11B 12A 27b

XX

RR

ss

A

B

D

TT

WW

VV

27n27p 27t

27u

27aa 2 35.532.5532 38.5

E

J

K

L

14 15a 16a 18a 21 23d 31 4038

M

K1

H1

HL31LS

LL31LS

X X

X

X

LL31EQB

HL33CR2

HL32CR2

HL31

DPHL31

DPHL31CR2 DPHL31EQB

DPHL31EQA

HL31EQB

HL31EQA

T-LL31EQB

LL34CR2UPS UPS

T-LL31CR2

LL31CR2

LL32CR2

LL35CR2

LL34CR1

LL33CR1

T-LL33CR1

HL32CR1

X

X

X

X

X X

X

X

X

X

X

X

XX

X

X X X X

X

X

X

X X X

LL33CR2 X

T-LL31LS

REFER TO DRAWINGS 2-

E4-1, 2-E4-2, 3-E4-3 AND 3-

E4-4

PAGING

X

X

X

X

DOWN TO SECOND FLOOR.

REFER TO DRAWING 0-E1-4 FOR

CONTINUATION

Space

2C217-2

Space

2C217-3

Alcove

3B164

Corridor

3B100H

Corridor

3B100F

2 Bedroom

3B124

Dictation

3B111B

Nourish.

3B127 Toilet

3B125

Nurse Station

3B110

Corridor

3B100D

Toilet/ Shower

3B154A

Toilet/ Shower

3B156A

Private

3B156

2 Bedroom Observation

3B158

Toilet/ Shower

3B158A

Corridor

3B100E

Elect./ Telecom.

3B112

Elect.

3B114

Storage

3B116

Toilet/ Shower

3B118A

Private

3B118

Toilet/ Shower

3B109A

Private

3B109

Ante Room

3B165

Toilet/ Shower

3B166A

Private Isolation

3B166

Corridor

3B100G

Toilet/ Shower

3B160A

2 Bedroom

3B160 Private

3B163

Toilet/ Shower

3B163A Toilet/

Shower

3B161A

2 Bedroom

3B161

Stair #4

3B002

Private

3B168

Toilet/ Shower

3B168A

Toilet/ Shower

3B170A

Private

3B170

Private

3B172

Toilet/ Shower

3B172A

Toilet/ Shower

3B174A

Private

3B174

Corridor

3B100k

Corridor

3B100L

Corridor

3B100J

Nurse/ Clinician

3B107

Head Nurse

3B105A

Dictation

3B105

Open Office

3B103

Elect.

3B149

Alcove

3B151

Office Social Work

3B101A

Office

3B178

Office

3B180

Elect.

3C105

Staff Lockers

3B100

Toilet/ Shower

3B100A

Private

3B102 Toilet/

Shower

3B102A

Private

3B104

Toilet/ Shower

3B104A

Toilet/ Shower

3B106A

Private

3B106

Private Isolation

3B108

Toilet/ Shower

3B108A

Clean Linen

3B109

Toilet

3C27

Shower

3C28

Staff Lockers

3C24

Shower

3C25

Toilet

3C26

Staff Lounge

3B176

VARC

Group Room

3A165

VARC

Office

3A163

Women's Health-Mammography

Suite

3A161

Toilet/ Shower

3A161A

Equipment Storage

3A159A

Equipment Storage

3A159

ECG/EKG

3A157

Toilet/ Shower

3A157A

Toilet/ Shower

3A155A

ECG/EKG

3A155

Pain Mgmt.

Exam Room

3A153

Pain Mgmt.

Check-In

3A151

Toilet/ Shower

3A153A

Pain Mgmt.

Cos/Office

3A138

Toilet/ Shower

3A138A

Toilet/ Shower

3A140A

Pain Mgmt.

Fluoroscopy

3A140

Corridor

3A100G

Stair #9

3A149

Pain Mgmt.

Exam Room

3A147

Clean

3A147A

Toilet/ Shower

3A145A

Pain Mgmt.

Exam Room

3A145

Pain Mgmt.

Work Room

3A143 Toilet/

Shower

3A143A

Toilet/ Shower

3A141A ICU Call Room

3A141

ICU Call Room

3A139

Toilet/ Shower

3A139A

Toilet/ Shower

3A137A

Dialysis

3A137

Office

3C104

Mammography

3C103

Vacant

3A167

Vacant

3A171

Women's Health-Office-Mammograms

3A169

Corridor

3A100A

Corridor

3A100C

Vacant

3A148

Lockers

3A146A

Vacant

3A146

Clean Utility

3A102

Soiled Utility

3A104

Vacant

3A144

Office

3A106

Head Nurse

3A142

Passage

3A100F

Corridor

3A100H

Nurse Station

3A108

Medication

3A108A

Dictation

3A108B

Nourish

3A118

Toilet

3A120

Elect.

3A122

Elect.

3A136

Corridor

3A100J

Storage

3A124

Storage

3A126

EMS

3A134 L.C.

3A132

EMS

3A128

L.C.

3A130

Telephone Equipment

3A135

Battery Room

3A135A

IRM

3A133 Corridor

3A100E

2 Bedroom

3A131

Toilet/ Shower

3A131A

Private

3A129 Toilet/

Shower

3A129A

Ante

3A127

Private Isolation

3A125

Toilet/ Shower

3A125A

Alcove

3A123

Storage

3A110

Corridor

3A100D

E.C.

3A115 Elect.

3A113

2 Bedroom

3A117

Storage

3A112

Storage

3A119 Private

3A114

Toilet/ Shower

3A114A

Toilet/ Shower

3A121A

Toilet/ Shower

3A117A

Toilet/ Shower

3A111A

Private

3A111

Private

3A109 Toilet/

Shower

3A109A

Toilet/ Shower

3A107A Private

3A107

Private

3A105 Toilet/

Shower

3A105A

Toilet/ Shower

3A103A Pain Med Phycian Office

3A103

Corridor

3A100B

IRM

3A101

Shaft

3C102

Female Restroom

3C101

Corridor

3C100A

Male Restroom

3C100

Stair #5

3C106

Elect.

3A100

Nursing Storage

3B167

Rec.

Therapist

3B169

Corridor

3B100M

Room

3B101 Meds

3B111A

Corridor

3B111

Telecom Room

3B162C Electrical

Room

3B162B

Low Volt Room

3B162E

S

59459

M.P. LONG

R

E

S

O F

I

R

G E

NO

I

S

P

E

N

E

D

ERT

L EA

E I N

G

R

T

S

TE

A

H

F OO

IO

FREDRICK, FREDRICK & HELLER

ENGINEERS, INC.

672 EAST ROYALTON ROAD

BROADVIEW HTS., OHIO 44147

TEL. (440) 546-9696

FAX: (440) 546-9699

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

1DESIGN AND CONSTRUCTION DOCUMENTS AS

INSTRUMENTS OF SERVICE ARE GIVEN IN

CONFIDENCE AND REMAIN THE PROPERTY OF

PERSPECTUS ARCHITECTURE. THE USE OF THIS

DESIGN AND THESE CONSTRUCTION

DOCUMENTS FOR PURPOSES OTHER THAN THE

SPECIFIC PROJECT NAMED HEREIN IS STRICTLY

PROHIBITED WITHOUT THE EXPRESSED

WRITTEN CONSENT OF PERSPECTUS

ARCHITECTURE. COPYRIGHT C 2019.

13212 Shaker Square Suite 204 Cleveland, Ohio 44120 P. 216.752.1800 F. 216.752.3833

18067

Z M y D o c u m e n ts \1

F F

H C

F R jd u a le .r v t

/2

/2

:5

:3

P

M

0-E1-5

10701 East Blvd. Cleveland, OH 44106

06/26/2020 MPL JRD

541-19-101Renovate Operating RoomsBID ISSUEPARTIAL THIRD FLOOR ELECTRICAL KEY PLAN

0' 8' 16' 32' 64'0' 8' 16' 32' 64'0' 8' 16' 32' 64'0' 8' 16' 32' 64'0' 8' 16' 32' 64'

1/16" = 1'-0"

PARTIAL THIRD FLOOR ELECTRICAL KEY PLAN 1N

PATHWAY SHOP DRAWINGS REQUIREMENTS

APPROXIMATE ROUTING SHOWN ON THESE DRAWINGS FOR ELECTRICAL FEEDERS ARE ONLY TO INDICATE GENERAL SCOPE OF WORK. CONTRACTOR MUST FIELD VERIFY ACTUAL ROUTING AND SUBMIT "PATHWAY SHOP DRAWING" TO VA COR FOR APPROVAL AND COORDINATION. DRAWING SHALL BE MINIMUM 1/16" = 1'-0" SCALE AND SHALL INDICATE, BUT IS NOT LIMITED TO, PROPOSED ROUTE, PULLBOXES, PENETRATIONS THROUGH FLOORS AND LIFE SAFETY BARRIERS (SMOKE AND FIRE), ETC. WHERE ROUTING IS ABOVE FINISHED CEILINGS IN OCCUPIED

AREAS, INDICATE APPROXIMATE LENGTH OF TIME AND EXTENT OF WORK REQUIRED.

NAME

TRANSFORMER

SIZE

PRIMARY

VOLTAGE

SECONDARY

VOLTAGE

INPUT

BREAKER

INPUT

BREAKER

AIC RATING 15A-2P

MOUNTING DIMENSIONS

20A-2P 30A-2P

BRANCH CIRCUIT BREAKERS

IP1B 480V-1ø 10KVA 120V-1ø 30A-2P 0 16 0 FLUSH 60"H X 25"W X 6"D

X

NOTES:

EXISTING BRANCH CIRCUIT WIRING -

REMOVE

AFTER RECONNECTION OF LOAD TO NEW

BREAKER OR STARTER

EXISTING BRANCH CIRCUIT WIRING TO

LOAD -

TO REMAIN

NEW TERMINAL BLOCKS IN MASTER TERMINAL

BLOCK (MTB) ENCLOSURES.

BREAKER OR STARTER IN NEW EQUIPMENT

BRANCH CIRCUIT/FEEDER TAG

REFER TO "BRANCH CIRCUIT/FEEDER

RECONNECTION TABLE"

FOR CONDUIT, WIRE SIZE, TERMINATION

METHODS, ETC.

225A

1.

2.

3.

4.

5.

6.

ELECTRICAL CONTRACTOR SHALL IDENTIFY ALL EXISTING CIRCUITS FED OUT OF EXISTING ELECTRICAL ROOM #2509 PRIOR TO DISCONNECTING IN PHASE 2. TRACE EXISTING CIRCUITS WITH AN ADVANCED WIRE TRACER THAT WORKS WITH ENERGIZED OR DE-ENERGIZED CIRCUITS AND IS CAPABLE OF INJECTING TRACE SIGNAL WITH CLAMP-ON ATTACHMENT FOR NON-CONTACT OPERATION. IN GENERAL, CIRCUITS MUST BE TRACED WHILE ENERGIZED. A WRITTEN LOAD IDENTIFICATION REPORT OF ALL EXISTING CIRCUITS FED FROM THIS ROOM SHALL BE SUBMITTED TO THE C.O.R. FOR REVIEW WITH THE FACILITIES MAINTENANCE DEPARTMENT. THE REPORT SHALL INDICATE; SOURCE EQUIPMENT NAME, CIRCUIT NUMBER, CIRCUIT RATING, LOAD DESCRIPTION, LOAD LOCATION, DATE OF TRACE AND INITIAL OF PERSON COMPLETING

TRACE.

PERFORM ALL CUT-OVER WORK OF RECONNECTED BRANCH CIRCUITS/FEEDERS DURING VAMC "OFF-HOURS". THIS WORK SHALL BE SCHEDULED WITH THE VA COR AT LEAST 14 DAYS IN ADVANCE. ALL PREMIUM COST (LABOR, EQUIPMENT RENTALS, ETC) ASSOCIATED WITH PERFORMING THIS WORK DURING SECOND SHIFTS, THIRD SHIFTS OR WEEKENDS SHALL BE INCLUDED IN THE CONTRACTORS BID PRICE. THE RECONNECTION OF FEEDERS AND BRANCH CIRCUITS MUST BE COMPLETED AT THE

END OF EACH OFF-HOURS SHIFT SUCH THAT THERE IS NO LOSS OF POWER FOR SURGERY.

QUANTITY OF BREAKERS ARE AN APPROXIMATION. CONTRACTOR SHALL FIELD VERIFY EXACT QUANTITY OF BREAKERS PRIOR TO DEMOLITION OF EXISTING

PANELBOARDS. REPORT ANY DISCREPANCIES TO ENGINEER.

CONTRACTOR SHALL TRACE EXISTING BRANCH CIRCUIT CONDUCTORS AND COORDINATE SHUT-DOWNS OF ALL EXISTING ELECTRICAL SYSTEMS WITH OWNER.

FOR EXISTING MULTIWIRE BRANCH CIRCUIT LOADS ROUTED IN THE FLOOR SLAB, THE CONTRACTOR SHALL TRACE THE CIRCUITS AND CONNECT THE NEW BRANCH CIRCUIT CONDUCTOR TO THE FIRST OUTLET/JUNCTION BOX IN THE CIRCUIT IN ORDER TO MAINTAIN ALL EXISTING CIRCUITING.

CONTRACTOR SHALL RECONNECT ALL EXISTING (REMAINING) ACTIVE CIRCUITS TO NEW ELECTRICAL DISTRIBUTION. REFER TO BRANCH CIRCUIT RECONNECTION

DETAILS FOR ELECTRICAL REQUIREMENTS.

B

EQUIPMENT

DESCRIPTION

FEEDER SCHEDULE

0.75"C - 3 #6 AND 1 #10EG

CONDUIT AND WIRE SIZE

ONE-LINE

TAG

50A-3Ø-3W

60A-3Ø-4W

100A-3Ø-3W

100A-3Ø-4W

150A-3Ø-3W

150A-3Ø-4W

250A-3Ø-3W

250A-3Ø-4W

1"C - 4 #4 AND 1 #8EG

1.25"C - 3 #2 AND 1 #8EG

1.25"C - 4 #2 AND 1 #8EG

1.5"C - 3 #1/0 AND 1 #6EG

1.5"C - 4 #1/0 AND 1 #6EG

2.5"C - 3 #4/0 AND 1 #4EG

2.5"C - 4 #4/0 AND 1 #4EG

LEGEND: POWER DISTRIBUTION ONE-LINE

175A-3Ø-4W 2"C - 4 #2/0 AND 1 #6EG

70A-3Ø-3W 1"C - 3 #4 AND 1 #8EG

0.75"C - 3 #10 AND 1 #10EG25A-3Ø-3W

125A-3Ø-3W 1.5"C - 3 #1/0 AND 1 #6EG

225A-3Ø-4W 2.5"C - 4 #4/0 AND 1 #4EG

0.75"C - 3 #8 AND 1 #10EG40A-3Ø-3W

0.75"C - 2 #8 AND 1 #10EG40A-1Ø-2W

60A-1Ø-2W 1"C - 2 #4 AND 1 #8EG

225A-3Ø-3W 2.5"C - 3 #4/0 H, 1 #4EG

60A-3Ø-3W 1"C - 3 #4 AND 1 #8EG

BRANCH CIRCUIT RECONNECTION DETAIL - TYPICAL

SINGLE ISOLATED POWER PANEL SCHEDULE

EXISTING EQUIPMENT, FEEDER/CIRCUIT - TO BE DEMOLISHED

NEW FEEDER/CIRCUIT AND FEEDER TAG, REFER TO FEEDER SCHEDULE ON THIS DRAWING

FOR ELECTRICAL REQUIREMENTS.

EXISTING EQUIPMENT, FEEDER/CIRCUIT - TO REMAIN

EQUIPMENT OUTLINE

SPLICE JOINT FOR RECONNECTION OF EXISTING CIRCUITS TO NEW SOURCE

BOLTED STATIONARY CIRCUIT BREAKER - 3-POLE UNLESS OTHERWISE NOTED

• GF - EQUIP BREAKER W/ GROUND FAULT TRIP

• GFA - EQUIP BREAKER W/ GROUND FAULT ALARM

• LSI - EQUIP BREAKER W/ ADJUSTABLE LONG, SHORT AND INSTANT. SETTINGS

400A-3Ø-4W

GROUNDING TERMINATION POINT FOR AN EQUIPMENT GROUNDING CONDUCTOR.

CONNECTION SHALL BE MADE BY BONDING THE EQUIPMENT GROUNDING CONDUCTOR TO

THE GROUNDED SERVICE CONDUCTOR AND THE GROUNDING ELECTRODE CONDUCTOR.

FUTURE EQUIPMENT, FEEDER/CIRCUIT - N.I.C.

CONTINUATION MARKER - REFER TO MATCHING MARKER AND ONE LINE CONTINUED

ON

ANOTHER DRAWING.

NAME (OLD NAME)

XR

IP2B 480V-1ø 10KVA 120V-1ø 30A-2P 0 16 0 FLUSH 60"H X 25"W X 6"D

IP5B 480V-1ø 10KVA 120V-1ø 30A-2P 0 16 0 FLUSH 60"H X 25"W X 6"D

IP6B 480V-1ø 10KVA 120V-1ø 30A-2P 0 16 0 FLUSH 60"H X 25"W X 6"D

IP7B 480V-1ø 10KVA 120V-1ø 30A-2P 0 16 0 FLUSH 60"H X 25"W X 6"D

IP8B 480V-1ø 10KVA 120V-1ø 30A-2P 0 16 0 FLUSH 60"H X 25"W X 6"D

IP9B 480V-1ø 10KVA 120V-1ø 30A-2P 0 16 0 FLUSH 60"H X 25"W X 6"D

IP10B 480V-1ø 10KVA 120V-1ø 30A-2P 0 16 0 FLUSH 60"H X 25"W X 6"D

ISOLATED POWER PANEL SCHEDULE NOTES:

ELECTRICAL CONDUCTORS CONNECTED TO ISOLATED POWER CIRCUITS SHALL BE TYPE XHHW-2 WITH DIELECTRIC CONSTANT OF LESS THAN 3.5. INCOMING PRIMARY AND GROUND CONDUCTORS ARE PERMITTED TO BE TYPE THHN.

SECONDARY CIRCUITS SHALL BE COLORED BROWN AND ORANGE WITH A DISTINCTIVE STRIPE IN A CONTRASTING COLOR PER NEC 517.160. BROWN AND ORANGE CONDUCTORS SHALL BE CONNECTED TO THE L2 BUS (HOT TERMINAL OF STANDARD RECEPTACLE) AND L1 BUS (NEUTRAL TERMINAL OF STANDARD RECEPTACLE), RESPECTIVELY. MAINTAIN CONVENTION THROUGHOUT THE INSTALLATION.

BRANCH CIRCUIT CONDUIT AND WIRING SHALL BE AS SHORT AND DIRECT TO THE LOAD AS POSSIBLE TO MINIMIZE LEAKAGE CURRENT. APPROXIMATELY 450FT IS THE MAXIMUM CUMULATIVE LENGTH FOR ALL BRANCH CIRCUITS FROM A SINGLE TRANSFORMER. CONTRACTOR SHALL KEEP DETAILED RECORD OF CIRCUIT LENGTHS FOR EACH PANELBOARD AND SUBMIT TO VA COR AND ENGINEER FOR REVIEW.

PULLING COMPOUNDS AND LUBRICANT ARE NOT PERMITTED.

ISOLATED POWER CIRCUITS SHALL BE KEPT SEPARATE FROM ALL OTHER CIRCUITS, INCLUDING OTHER ISOLATE POWER CIRCUITS FROM ANOTHER SYSTEM.

CONNECT ALL RECEPTACLES AND EQUIPMENT BACK TO REFERENCE GROUND BOX IN ISOLATE POWER PANEL.

BOND ALL ISOLATED POWER PANELBOARDS WITHIN THE SAME ROOM TO EACH OTHER VIA #6 AWG CONDUCTOR.

LINE ISOLATION MONITOR (LIM) SHALL HAVE DIGITAL READOUT FOR TOTAL HAZARD CURRENT (THC), GREEN SIGNAL LIGHT (WHEN SYSTEM IS ISOLATED FROM GROUND), RED SIGNAL LIGHT AND BUZZER WHEN THC EXCEEDS 5mA SELF-TEST, AND SELF-CALIBRATION. THE LINE ISOLATION MONITOR SHALL NO ALARM FOR A FAULT HAZARD CURRENT OF LESS THAT 3.7 mA. THE LIMS SHALL BE FLUSH MOUNTED ON THE FRONT OF THE PANEL SO THAT THE LIM SIGNALS ARE CLEARLY VISIBLE AT ALL TIMES. THE LIM SIGNALS MUST NOT BE OBSCURED WHEN THE CIRCUIT BREAKER DOOR IS OPEN. THE LIM SHALL BE RECOGNIZED UNDER UL STANDARD 1022.

REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION.

X

XR

NAME

PRIMARY

VOLTAGE SEC. A

(IP#A)

TRANSFORMER

LIM

INPUT BREAKER SEC A (IP#A) - 120V BREAKERS

IP1A/IP1L 277V-1ø DIGITAL

METER

70"H X 35"W X 8"D

IP5A/IP5L 277V-1ø 70"H X 35"W X 8"D

IP2A/IP2L 277V-1ø 70"H X 35"W X 8"D

IP6A/IP6L 277V-1ø 70"H X 35"W X 8"D

IP7A/IP7L 277V-1ø 70"H X 35"W X 8"D

IP8A/IP8L 277V-1ø 70"H X 35"W X 8"D

IP9A/IP9L 277V-1ø 70"H X 35"W X 8"D

IP10A/IP10L 277V-1ø 70"H X 35"W X 8"D

LIM

DIGITAL

METER

DIGITAL

METER

DIGITAL

METER

DIGITAL

METER

DIGITAL

METER

DIGITAL

METER

DIGITAL

METER

DIGITAL

METER

14,000 AIC

14,000 AIC

14,000 AIC

14,000 AIC

14,000 AIC

14,000 AIC

14,000 AIC

14,000 AIC

GROUND BUS

(24) #12 - #6

TERMINATIONS

(24) #12 - #6

TERMINATIONS

(24) #12 - #6

TERMINATIONS

(24) #12 - #6

TERMINATIONS

(24) #12 - #6

TERMINATIONS

(24) #12 - #6

TERMINATIONS

(24) #12 - #6

TERMINATIONS

(24) #12 - #6

TERMINATIONS

SEC. B

(IP#L)

SECONDARY TRANSFORMER

10KVA

10KVA

10KVA

10KVA

10KVA

10KVA

10KVA

10KVA

5KVA

5KVA

5KVA

5KVA

5KVA

5KVA

5KVA

5KVA

120V

120V

120V

120V

120V

120V

120V

120V

208V

208V

208V

208V

208V

208V

208V

208V

DIGITAL

METER

DIGITAL

METER

DIGITAL

METER

DIGITAL

METER

DIGITAL

METER

DIGITAL

METER

DIGITAL

METER

45A-1P 25A-1P

45A-1P 25A-1P

45A-1P 25A-1P

45A-1P 25A-1P

45A-1P 25A-1P

45A-1P 25A-1P

45A-1P 25A-1P

45A-1P 25A-1P

INPUT BREAKER

AIC RATING

14,000AIC

14,000AIC

14,000AIC

14,000AIC

14,000AIC

14,000AIC

14,000AIC

14,000AIC

SEC B(IP#B) - 208V BREAKERS

15A-2P 20A-2P 30A-2P

0 16 0

0 16 0

0 16 0

0 16 0

0 16 0

0 16 0

0 16 0

0 16 0

20A-2P 30A-2P

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

MOUNTING DIMENSIONS

FLUSH

FLUSH

FLUSH

FLUSH

FLUSH

FLUSH

FLUSH

FLUSH

GROUND BUS

(24) #12 - #6

TERMINATIONS

(24) #12 - #6

TERMINATIONS

(24) #12 - #6

TERMINATIONS

(24) #12 - #6

TERMINATIONS

(24) #12 - #6

TERMINATIONS

(24) #12 - #6

TERMINATIONS

(24) #12 - #6

TERMINATIONS

(24) #12 - #6

TERMINATIONS

DUAL VOLTAGE ISOLATED POWER PANEL SCHEDULE

SEC. A

(IP#A)

SEC. B

(IP#L)

SEC. A

(IP#A)

SEC. B

(IP#L)

0.75"C - 2 #12 AND 1 #12EG20A-1Ø-2W

MANUFACTURER MODEL

PG LIFELINK

PG LIFELINK

PG LIFELINK

PG LIFELINK

PG LIFELINK

PG LIFELINK

PG LIFELINK

PG LIFELINK

IPP

IPP

IPP

IPP

IPP

IPP

IPP

IPP

MANUFACTURER MODEL

PG LIFELINK

PG LIFELINK

PG LIFELINK

PG LIFELINK

PG LIFELINK

PG LIFELINK

PG LIFELINK

PG LIFELINK

IPX

IPX

IPX

IPX

IPX

IPX

IPX

IPX

0.75"C - 2 #10 AND 1 #10EG25A-1Ø-2W

1.

2.

3.

4.

5.

6.

7.

8.

9.

S

59459

M.P. LONG

R

E

S

O F

I

R

G E

NO

I

S

P

E

N

E

D

ERT

L EA

E I N

G

R

T

S

TE

A

H

F OO

IO

FREDRICK, FREDRICK & HELLER

ENGINEERS, INC.

672 EAST ROYALTON ROAD

BROADVIEW HTS., OHIO 44147

TEL. (440) 546-9696

FAX: (440) 546-9699

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

1DESIGN AND CONSTRUCTION…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .