C_62.5kW PV.pdf

PDF 88 KB Posted

Attached to
Virgin Islands Renewable Energy Systems Federal contract opportunity
Solicitation number
W50S93-20-B-5002-0001
Issued by
Department of the Army Michigan Army National Guard

About this file

This document contains a technical specification for a 62.5 kW photovoltaic system and the related federal contract solicitation for renewable energy systems in the U.S. Virgin Islands. The technical specification provides projected annual energy generation figures calculated using the PVWatts model, indicating the system would generate approximately 102,285 kWh per year with a range of 99,482 to 104,985 kWh. It also lists component details such as the DC system size, module type, array configuration, losses, and inverter efficiency. The related solicitation is from the Department of the Army Michigan Army National Guard to design and install renewable energy systems on St. Croix and provides a point of contact for site visits. Interested offerors are instructed to submit proposals to the specified contracting office by the amended due date.

View the file

Other files for this federal contract opportunity

Other files attached to Virgin Islands Renewable Energy Systems, newest first.
File Type Posted
FAA 7460_Response.pdf PDF
C_Glare Report.pdf PDF
W50S93-20-B-5002-0001.pdf PDF
VIANG Renewable Energy_SPECS.pdf PDF
A5_PanelClaw.pdf PDF
A_CUT SHEETS.pdf PDF
160861.20 - New Wind Turbine - Air National Guard Station - USVI - Geotechnical Report.pdf PDF
G-001-Layout1.pdf PDF
D_FAA FORMS.pdf PDF
C_1VIANG VD.pdf PDF
A1_WS-0001_P10-20.pdf PDF
Structural.pdf PDF
C_20kW Wind Turbine.pdf PDF
Electrical.pdf PDF
C_1CUT SHEETS.pdf PDF
A2_sunmodule-plus-mono-5-busbar-datasheet.pdf PDF
A3_IQ6-IQ6-plus_DS_EN-US.pdf PDF
SANGB Base Access List.xlsx XLSX spreadsheet
A4_S-5.pdf PDF
New Wind Turbine USVI - Geotechnical Report.pdf PDF
Show all 20

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Caution: Photovoltaic system performance predictions calculated by PVWatts include many inherent assumptions and uncertainties and do not reflect variations between PV technologies nor site-specific characteristics except as represented by

PVWatts inputs. For example, PV modules with better performance are not differentiated within PVWatts from lesser performing modules. Both NREL and private companies provide more sophisticated PV modeling tools (such as the System Advisor

Model at http://sam.nrel.gov) that allow for more precise and complex modeling of PV systems.

The expected range is based on 30 years of actual weather data at the given location and is intended to provide an indication of the variation you might see. For more information, please refer to this NREL report:

The Error Report.

Disclaimer: The PVWatts Model ("Model") is provided by the National Renewable

Energy Laboratory ("NREL"), which is operated by the Alliance for Sustainable

Energy, LLC ("Alliance") for the U.S.

Department Of Energy ("DOE") and may be used for any purpose whatsoever.

The names DOE/NREL/ALLIANCE shall not be used in any representation, advertising, publicity or other manner whatsoever to endorse or promote any entity that adopts or uses the Model. DOE/NREL/ALLIANCE shall not provide any support, consulting, training or assistance of any kind with regard to the use of the Model or any updates, revisions or new versions of the Model.

YOU AGREE TO INDEMNIFY

DOE/NREL/ALLIANCE, AND ITS AFFILIATES,

OFFICERS, AGENTS, AND EMPLOYEES

AGAINST ANY CLAIM OR DEMAND,

INCLUDING REASONABLE ATTORNEYS'

FEES, RELATED TO YOUR USE, RELIANCE,

OR ADOPTION OF THE MODEL FOR ANY

PURPOSE WHATSOEVER. THE MODEL IS

PROVIDED BY DOE/NREL/ALLIANCE "AS IS"

AND ANY EXPRESS OR IMPLIED

WARRANTIES, INCLUDING BUT NOT

LIMITED TO THE IMPLIED WARRANTIES OF

MERCHANTABILITY AND FITNESS FOR A

PARTICULAR PURPOSE ARE EXPRESSLY

DISCLAIMED. IN NO EVENT SHALL

DOE/NREL/ALLIANCE BE LIABLE FOR ANY

SPECIAL, INDIRECT OR CONSEQUENTIAL

DAMAGES OR ANY DAMAGES WHATSOEVER,

INCLUDING BUT NOT LIMITED TO CLAIMS

ASSOCIATED WITH THE LOSS OF DATA OR

PROFITS, WHICH MAY RESULT FROM ANY

ACTION IN CONTRACT, NEGLIGENCE OR

OTHER TORTIOUS CLAIM THAT ARISES

OUT OF OR IN CONNECTION WITH THE USE

OR PERFORMANCE OF THE MODEL.

The energy output range is based on analysis of 30 years of historical weather data for nearby , and is intended to provide an indication of the possible interannual variability in generation for a Fixed (open rack) PV system at this location.

102,284 kWh/Year*RESULTS

System output may range from 99,482 to 104,985kWh per year near this location.

Month Solar Radiation

( kWh / m

/ day )

AC Energy ( kWh )

Energy Value

January 5.22 8,277 3,890

February 5.62 8,023 3,771

March 6.09 9,581 4,503

April 5.94 9,072 4,264

May 5.45 8,563 4,025

June 5.56 8,493 3,992

July 5.69 8,916 4,191

August 5.74 8,967 4,214

September 5.84 8,828 4,149

October 5.43 8,518 4,003

November 4.89 7,445 3,499

December 4.82 7,602 3,573

Annual 5.52 102,285 $ 48,074

Location and Station Identification

Requested Location us vi

Weather Data Source (TMY2) SAN JUAN, FL 80 mi

Latitude 18.43° N

Longitude 66° W

PV System Specifications (Commercial)

DC System Size 62.44 kW

Module Type Premium

Array Type Fixed (roof mount)

Array Tilt 20°

Array Azimuth 180°

System Losses 10%

Inverter Efficiency 97%

DC to AC Size Ratio 1.1

Economics

Average Cost of Electricity Purchased from Utility

0.47 $/kWh

Performance Metrics

Capacity Factor 18.7%

Page 1 of 1PVWatts Calculator

9/19/2017http://pvwatts.nrel.gov/pvwatts.php