A5_PanelClaw.pdf
PDF 328 KB Posted
- Attached to
- Virgin Islands Renewable Energy Systems Federal contract opportunity
- Solicitation number
- W50S93-20-B-5002-0001
About this file
This document contains specifications for solar panel mounting systems and details for a related federal contract opportunity. The specifications cover PanelClaw mounting systems for roof slopes up to 70 degrees, wind speeds up to 150 mph, building heights up to 60 feet, and setbacks as low as 3 feet. Standard ballast block sizes and array layout guidelines are also provided. The related federal contract opportunity is a solicitation from the Department of the Army Michigan Army National Guard for renewable energy systems in the Virgin Islands. Responses are due on August 28, 2020 and the contract is to be awarded by September 30, 2020. The opportunity involves designing and installing solar photovoltaic systems at various sites on St. Croix and St. Thomas in the U.S. Virgin Islands.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| C_20kW Wind Turbine.pdf | ||
| Electrical.pdf | ||
| FAA 7460_Response.pdf | ||
| C_Glare Report.pdf | ||
| W50S93-20-B-5002-0001.pdf | ||
| VIANG Renewable Energy_SPECS.pdf | ||
| A_CUT SHEETS.pdf | ||
| 160861.20 - New Wind Turbine - Air National Guard Station - USVI - Geotechnical Report.pdf | ||
| G-001-Layout1.pdf | ||
| D_FAA FORMS.pdf | ||
| C_62.5kW PV.pdf | ||
| C_1VIANG VD.pdf | ||
| A1_WS-0001_P10-20.pdf | ||
| Structural.pdf | ||
| C_1CUT SHEETS.pdf | ||
| A2_sunmodule-plus-mono-5-busbar-datasheet.pdf | ||
| A3_IQ6-IQ6-plus_DS_EN-US.pdf | ||
| SANGB Base Access List.xlsx | XLSX spreadsheet | |
| A4_S-5.pdf | ||
| New Wind Turbine USVI - Geotechnical Report.pdf |
Show all 20
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
© 2016 PanelClaw, Inc. All Rights Reserved.
PA R T N E RS H I P | We h e l p y o u w i n S E R V I C E | A t o Z p ro j e c t s u p p o r t R E L I A B I L I T Y | M a d e t o o u t l a s t
Polar Bear® III HD SPECIFICATIONS and LAYOUT GUIDELINES
10 Degree 5 Degree
Polar Bear® III HD 5˚ & 10˚ Specifications
Roof Loading 2.5 psf to 12 psf (12.2 kg/m² to 58.6 kg/m²) including racking, modules and ballast
Roof Slope 7˚ max slope (1.5/12 pitch) in all directions
Wind Speed 150 mph (193 km/h) – 3 second gust per ASCE 7-05 (190 mph per ASCE 7-10) Higher wind speeds require PanelClaw engineering review
Exposures B and C D upon request
Seismic Design Category
A, B, C, D Category D may require mechanical attachments, or as required by the permitting authority
Maximum Building Height
60 ft (18.3 m), measured from grade Heights above 60 ft generally require mechanical attachments; check with PanelClaw engineering
Standard Setback 4 ft (1.2 m) Set backs as low as 3 ft (0.9 m) are possible, but require PanelClaw engineering review
Roof Material EPDM, TPO, PVC, Mod Bitumen, Asphalt, Coal Tar, Foam, Concrete, and Gravel
Fire Certification Requirements
System Fire Rating Class A with Type 1 and Type 2 modules No additional components required for compliance
Ballast Block Size Nominal 2”x8”x16”, 3”x8”x16”, or 4”x8”x16” blocks Actual dimensions: 1 5/8” or 2 5/8” or 3 5/8”x7 5/8”x15 5/8” with +/- 1/8” tolerance
2 v1
Array Layout Guidelines for 5˚ & 10˚
Maximum array row length - 150’ | Maximum array column length - 150’
Maintain a minimum of 6” clearance from obstructions and separate sub arrays
Diagonal connections between arrays not allowed
3 v1