This document contains technical specifications for Enphase IQ 6 and IQ 6+ Microinverters. The specifications cover product details such as input voltage ranges, output power levels, efficiency ratings, environmental tolerances, dimensions, weight, and compliance with relevant standards. The microinverters are designed for use in residential and small commercial solar installations, integrating with the Enphase Envoy monitoring system.
The related federal contract opportunity is a solicitation from the Department of the Army Michigan Army National Guard seeking proposals for renewable energy systems to be installed in the U.S. Virgin Islands. Offerors are instructed to submit proposals to the specified contracting office by the amended due date. The opportunity involves designing and installing solar photovoltaic arrays on government sites in St. Croix utilizing microinverters meeting the specifications documented.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| FAA 7460_Response.pdf | ||
| C_Glare Report.pdf | ||
| W50S93-20-B-5002-0001.pdf | ||
| VIANG Renewable Energy_SPECS.pdf | ||
| A5_PanelClaw.pdf | ||
| A_CUT SHEETS.pdf | ||
| C_20kW Wind Turbine.pdf | ||
| Electrical.pdf | ||
| 160861.20 - New Wind Turbine - Air National Guard Station - USVI - Geotechnical Report.pdf | ||
| G-001-Layout1.pdf | ||
| D_FAA FORMS.pdf | ||
| C_62.5kW PV.pdf | ||
| C_1VIANG VD.pdf | ||
| A1_WS-0001_P10-20.pdf | ||
| Structural.pdf | ||
| C_1CUT SHEETS.pdf | ||
| A2_sunmodule-plus-mono-5-busbar-datasheet.pdf | ||
| SANGB Base Access List.xlsx | XLSX spreadsheet | |
| A4_S-5.pdf | ||
| New Wind Turbine USVI - Geotechnical Report.pdf |
Show all 20
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
The high-powered smart grid-ready Enphase IQ 6 Micro™ and Enphase IQ 6+ Micro™ dramatically simplify the installation process while achieving the highest efficiency for module-level power electronics.
Part of the Enphase IQ System, the IQ 6 and IQ 6+ Micro integrate seamlessly with the Enphase IQ Envoy™, Enphase Q Aggregator™, Enphase IQ Battery™, and the Enphase Enlighten™ monitoring and analysis software.
The IQ 6 and IQ 6+ Micro extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years.
Enphase IQ 6 and IQ 6+ Microinverters
To learn more about Enphase offerings, visit enphase.com
Data Sheet Enphase Microinverters
Easy to Install
• Lightweight and simple
• Faster installation with improved two-wire cabling
• Built-in rapid shutdown compliant (NEC 2014 & 2017)
Productive and Reliable
• Optimized for high powered 60-cell and 72-cell* modules
• More than a million hours of testing
• Class II double-insulated enclosure
• UL listed
Smart Grid Ready
• Complies with fixed power factor, voltage and frequency ride-through requirements
• Remotely updates to respond to changing grid requirements
• Configurable for varying grid profiles
• Meets CA Rule 21 (UL 1741-SA)
* The IQ 6+ Micro is required to support 72-cell modules http://www.enphase.com
To learn more about Enphase offerings, visit enphase.com © 2017 Enphase Energy. All rights reserved. All trademarks or brands used are the property of Enphase Energy, Inc.
2017-09-11
INPUT DATA (DC) IQ6-60-2-US / IQ6-60-5-US IQ6PLUS-72-2-US / IQ6PLUS-72-5-US
Commonly used module pairings¹ 195 W - 330 W + 235 W - 400 W + Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules Maximum input DC voltage 48 V 62 V Peak power tracking voltage 27 V - 37 V 27 V - 45 V Operating range 16 V - 48 V 16 V - 62 V
| Min/Max | start | voltage 22 V / 48 V 22 V / 62 V | ||||||||||
| Max | DC | short | circuit | current | (module | Isc) 15 A 15 A | ||||||
| Overvoltage | class | DC | port II II | |||||||||
| DC | port | backfeed | under | single | fault 0 A 0 A | |||||||
| PV | array | configuration 1 | x | 1 | ungrounded | array; | No | additional | DC | side | protection | required; |
AC side protection requires max 20A per branch circuit OUTPUT DATA (AC) IQ 6 Microinverter IQ 6+ Microinverter Peak output power 240 VA 290 VA Maximum continuous output power 230 VA 280 VA Nominal (L-L) voltage/range² 240 V / 211-264 V 208 V / 183-229 V 240 V / 211-264 V 208 V / 183-229 V Maximum continuous output current 0.96 A 1.11 A 1.17 A 1.35 A Nominal frequency 60 Hz 60 Hz Extended frequency range 47 - 68 Hz 47 - 68 Hz Power factor at rated power 1.0 1.0 Maximum units per 20 A (L-L) branch circuit 16 (240 VAC) 13 (240 VAC)
14 (208 VAC) 11 (208 VAC)
Overvoltage class AC port III III AC port backfeed under single fault 0 A 0 A Power factor (adjustable) 0.7 leading ... 0.7 lagging 0.7 leading ... 0.7 lagging
EFFICIENCY @240 V @208 V @240 V @208 V
CEC weighted efficiency 97.0 % 97.0 % 97.0 % 97.0 %
MECHANICAL DATA
Ambient temperature range -40ºC to +65ºC Relative humidity range 4% to 100% (condensing) Connector type MC4 (-2-US) or Amphenol H4 UTX (-5-US) Dimensions (WxHxD) 219 mm x 191 mm x 37.9 mm (without bracket) Weight 1.5 kg (3.3 lbs) Cooling Natural convection - No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated Environmental category / UV exposure rating Outdoor - NEMA 250, type 6 (IP67)
FEATURES
Communication Power line Monitoring Enlighten Manager and MyEnlighten monitoring options
Compatible with Enphase IQ Envoy Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690.
Compliance CA Rule 21 (UL 1741-SA)
UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01
This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according manufacturer’s instructions.
| 1. | No | enforced | DC/AC | ratio. | See | the | compatibility | calculator | at | enphase.com/en-us/support/module-compatibility. | |||
| 2. | Nominal | voltage | range | can | be | extended | beyond | nominal | if | required | by | the | utility. |
Enphase IQ 6 and IQ 6+ Microinverters http://www.enphase.com enphase.com/en-us/support/module-compatibility
File details come from the government source that posted it. Updated .