C-501.pdf

PDF 156 KB Posted

Attached to
Force Protection Repairs Federal contract opportunity
Solicitation number
W50S8U22B0004
Issued by
Department of the Army National Guard

About this file

This document contains a solicitation for a federal contract opportunity and related technical drawings. The solicitation seeks bids to upgrade force protection at an Air National Guard Base in Tulsa, Oklahoma. Services required include providing all plant, labor, materials, tools and equipment to complete upgrades, such as installing security bollards, gates, fencing and drop bars. The total small business set-aside contract value is estimated between $100,000 to $250,000. The technical drawings depict details for security measures like removable bollards, gate posts, swing gates and connections to asphalt and concrete. The solicitation number is W50S8U22B0004 and was issued by the Tulsa Air National Guard for the Department of the Army National Guard. Funds may become available by September 2022, and award will be to the responsible bidder offering the most advantageous price.

View the file

Other files for this federal contract opportunity

Other files attached to Force Protection Repairs, newest first.
File Type Posted
Abstract of Offers OF 1419 - Force Protection.pdf PDF
Attendance Sheet Bid opening Force Protection_Redacted.pdf PDF
W50S8U-22-B-0004-0001.pdf PDF
Pre-Bid RFI Force Protection 25 May 22.pdf PDF
Site Visit Slides - Force Protection repairs.ppt PPT presentation
Site Visit Minutes - Force Protection repairs.pdf PDF
Site Visit Sign In - Force Protection repairs Signed_Redacted.pdf PDF
C-315-317_Redacted.pdf PDF
C-101.pdf PDF
A-501.pdf PDF
RFI Template Force Protection Repairs.docx DOCX document
SOW - Force Protection v1.4.docx DOCX document
22-B-0004.pdf PDF
Sliding Gate Drawing.pdf PDF
Show all 14

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CO

M

BA

A I R M

AND

CO

M

T

AutoCAD SHX Text

NTS

AutoCAD SHX Text

TYPICAL SECURITY MEASURES AT DITCH

AutoCAD SHX Text E

AutoCAD SHX Text 1/2" = 1'-0"

AutoCAD SHX Text

6" REMOVABLE BOLLARD

AutoCAD SHX Text A

AutoCAD SHX Text

6" HANDLE, ALIGN ON FRONT & BACK OF BOLLARD

AutoCAD SHX Text

YELLOW REFLECTIVE TAPE, 3" WIDE AND 6" FROM TOP OF BOLLARD

AutoCAD SHX Text

EXISTING SUB-BASE

AutoCAD SHX Text

EXISTING SOIL

AutoCAD SHX Text

4,000 PSI CONCRETE

AutoCAD SHX Text

STEEL GROUND INSERT

AutoCAD SHX Text

EXISTING ASPHALT

AutoCAD SHX Text 1/2" = 1'-0"

AutoCAD SHX Text

GATE POST DETAIL

AutoCAD SHX Text B

AutoCAD SHX Text

EXISTING SOIL

AutoCAD SHX Text

4,000 PSI CONCRETE

AutoCAD SHX Text

6.625" DIA. POST

AutoCAD SHX Text

POST CAP

AutoCAD SHX Text 1/4" = 1'-0"

AutoCAD SHX Text

SWING GATE DETAIL

AutoCAD SHX Text G

AutoCAD SHX Text

EXISTING SOIL

AutoCAD SHX Text

4,000 PSI CONCRETE

AutoCAD SHX Text

POST CAP

AutoCAD SHX Text

EXISTING 4" GATE POST

AutoCAD SHX Text

EXISTING FOOTING

AutoCAD SHX Text

5" CONC WALK WITH BUCKEYE ULTRA FIBER 500

AutoCAD SHX Text

NEW 4" DIA. POST

AutoCAD SHX Text

SEE DETAIL "B" GATE POST

AutoCAD SHX Text

HINGE SIDE

AutoCAD SHX Text

REMOVE EXISTING CHAINLINK FENCE

AutoCAD SHX Text

TO INSTALL NEW POST AND GATE.

AutoCAD SHX Text

REINSTALL EXISTING FENCE

AutoCAD SHX Text 1/2" = 1'-0"

AutoCAD SHX Text

DROP BAR DETAIL

AutoCAD SHX Text C

AutoCAD SHX Text

EXISTING SOIL

AutoCAD SHX Text

EXISTING SUB-BASE

AutoCAD SHX Text

EXISTING ASPHALT

AutoCAD SHX Text

COMPACTED SAND

AutoCAD SHX Text

1" DIA. PVC PIPE

AutoCAD SHX Text

NTS

AutoCAD SHX Text

TYPICAL SECURITY MEASURES AT DITCH

AutoCAD SHX Text F

AutoCAD SHX Text

CLR

AutoCAD SHX Text

EXISTING CONC. DRIVE

AutoCAD SHX Text

LOCKSET TO MATCH

AutoCAD SHX Text

EXISTING ON BASE

AutoCAD SHX Text

1/2" EXPANSION JOINT (ALL SIDES)

AutoCAD SHX Text

EXISTING ASPHALT

AutoCAD SHX Text

EXISTING SUB-BASE

AutoCAD SHX Text 1/2" = 1'-0"

AutoCAD SHX Text

CONC. TO ASPHALT DETAIL

AutoCAD SHX Text D

AutoCAD SHX Text

#4 REBAR AT 24" O.C.E.W.

AutoCAD SHX Text

9" 4,000 PSI EARLY STRENGTH CONC

AutoCAD SHX Text

EXISTING SOIL

AutoCAD SHX Text

SELECT FILL, COMPACTED TO 95% PROCTOR DENSITY

AutoCAD SHX Text OKLAHOMA AIR NATIONAL GUARD - 138th FIGHTER WING

AutoCAD SHX Text

DEPARTMENT OF THE ARMY AND THE AIR FORCE

AutoCAD SHX Text

NATIONAL GUARD BUREAU - WASHINGTON,D.C.

AutoCAD SHX Text C-501

AutoCAD SHX Text of sheets

AutoCAD SHX Text

AutoCAD SHX Text 1/4"=1'-0"

AutoCAD SHX Text Checked By:

AutoCAD SHX Text Scale:

AutoCAD SHX Text Sheet

AutoCAD SHX Text Drawn By:

AutoCAD SHX Text

JC

AutoCAD SHX Text

REVISION:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

6JAN2021

AutoCAD SHX Text

PROJECT

AutoCAD SHX Text

TULSA I.A.P., OKLAHOMA

AutoCAD SHX Text

DETAILS

AutoCAD SHX Text

BCE: LT COL KURT STEPHENS

AutoCAD SHX Text 138th CIVIL ENGINEER SQUADRON

AutoCAD SHX Text

OKLAHOMA AIR NATIONAL GUARD TULSA I.A.P. OK.

AutoCAD SHX Text

DBCE: MAJ PATRICK DEERING

File details come from the government source that posted it. Updated .