C-501.pdf
PDF 156 KB Posted
- Attached to
- Force Protection Repairs Federal contract opportunity
- Solicitation number
- W50S8U22B0004
- Issued by
- Department of the Army National Guard
About this file
This document contains a solicitation for a federal contract opportunity and related technical drawings. The solicitation seeks bids to upgrade force protection at an Air National Guard Base in Tulsa, Oklahoma. Services required include providing all plant, labor, materials, tools and equipment to complete upgrades, such as installing security bollards, gates, fencing and drop bars. The total small business set-aside contract value is estimated between $100,000 to $250,000. The technical drawings depict details for security measures like removable bollards, gate posts, swing gates and connections to asphalt and concrete. The solicitation number is W50S8U22B0004 and was issued by the Tulsa Air National Guard for the Department of the Army National Guard. Funds may become available by September 2022, and award will be to the responsible bidder offering the most advantageous price.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Abstract of Offers OF 1419 - Force Protection.pdf | ||
| Attendance Sheet Bid opening Force Protection_Redacted.pdf | ||
| W50S8U-22-B-0004-0001.pdf | ||
| Pre-Bid RFI Force Protection 25 May 22.pdf | ||
| Site Visit Slides - Force Protection repairs.ppt | PPT presentation | |
| Site Visit Minutes - Force Protection repairs.pdf | ||
| Site Visit Sign In - Force Protection repairs Signed_Redacted.pdf | ||
| C-315-317_Redacted.pdf | ||
| C-101.pdf | ||
| A-501.pdf | ||
| RFI Template Force Protection Repairs.docx | DOCX document | |
| SOW - Force Protection v1.4.docx | DOCX document | |
| 22-B-0004.pdf | ||
| Sliding Gate Drawing.pdf |
Show all 14
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CO
M
BA
A I R M
AND
CO
M
T
AutoCAD SHX Text
NTS
AutoCAD SHX Text
TYPICAL SECURITY MEASURES AT DITCH
AutoCAD SHX Text E
AutoCAD SHX Text 1/2" = 1'-0"
AutoCAD SHX Text
6" REMOVABLE BOLLARD
AutoCAD SHX Text A
AutoCAD SHX Text
6" HANDLE, ALIGN ON FRONT & BACK OF BOLLARD
AutoCAD SHX Text
YELLOW REFLECTIVE TAPE, 3" WIDE AND 6" FROM TOP OF BOLLARD
AutoCAD SHX Text
EXISTING SUB-BASE
AutoCAD SHX Text
EXISTING SOIL
AutoCAD SHX Text
4,000 PSI CONCRETE
AutoCAD SHX Text
STEEL GROUND INSERT
AutoCAD SHX Text
EXISTING ASPHALT
AutoCAD SHX Text 1/2" = 1'-0"
AutoCAD SHX Text
GATE POST DETAIL
AutoCAD SHX Text B
AutoCAD SHX Text
EXISTING SOIL
AutoCAD SHX Text
4,000 PSI CONCRETE
AutoCAD SHX Text
6.625" DIA. POST
AutoCAD SHX Text
POST CAP
AutoCAD SHX Text 1/4" = 1'-0"
AutoCAD SHX Text
SWING GATE DETAIL
AutoCAD SHX Text G
AutoCAD SHX Text
EXISTING SOIL
AutoCAD SHX Text
4,000 PSI CONCRETE
AutoCAD SHX Text
POST CAP
AutoCAD SHX Text
EXISTING 4" GATE POST
AutoCAD SHX Text
EXISTING FOOTING
AutoCAD SHX Text
5" CONC WALK WITH BUCKEYE ULTRA FIBER 500
AutoCAD SHX Text
NEW 4" DIA. POST
AutoCAD SHX Text
SEE DETAIL "B" GATE POST
AutoCAD SHX Text
HINGE SIDE
AutoCAD SHX Text
REMOVE EXISTING CHAINLINK FENCE
AutoCAD SHX Text
TO INSTALL NEW POST AND GATE.
AutoCAD SHX Text
REINSTALL EXISTING FENCE
AutoCAD SHX Text 1/2" = 1'-0"
AutoCAD SHX Text
DROP BAR DETAIL
AutoCAD SHX Text C
AutoCAD SHX Text
EXISTING SOIL
AutoCAD SHX Text
EXISTING SUB-BASE
AutoCAD SHX Text
EXISTING ASPHALT
AutoCAD SHX Text
COMPACTED SAND
AutoCAD SHX Text
1" DIA. PVC PIPE
AutoCAD SHX Text
NTS
AutoCAD SHX Text
TYPICAL SECURITY MEASURES AT DITCH
AutoCAD SHX Text F
AutoCAD SHX Text
CLR
AutoCAD SHX Text
EXISTING CONC. DRIVE
AutoCAD SHX Text
LOCKSET TO MATCH
AutoCAD SHX Text
EXISTING ON BASE
AutoCAD SHX Text
1/2" EXPANSION JOINT (ALL SIDES)
AutoCAD SHX Text
EXISTING ASPHALT
AutoCAD SHX Text
EXISTING SUB-BASE
AutoCAD SHX Text 1/2" = 1'-0"
AutoCAD SHX Text
CONC. TO ASPHALT DETAIL
AutoCAD SHX Text D
AutoCAD SHX Text
#4 REBAR AT 24" O.C.E.W.
AutoCAD SHX Text
9" 4,000 PSI EARLY STRENGTH CONC
AutoCAD SHX Text
EXISTING SOIL
AutoCAD SHX Text
SELECT FILL, COMPACTED TO 95% PROCTOR DENSITY
AutoCAD SHX Text OKLAHOMA AIR NATIONAL GUARD - 138th FIGHTER WING
AutoCAD SHX Text
DEPARTMENT OF THE ARMY AND THE AIR FORCE
AutoCAD SHX Text
NATIONAL GUARD BUREAU - WASHINGTON,D.C.
AutoCAD SHX Text C-501
AutoCAD SHX Text of sheets
AutoCAD SHX Text
AutoCAD SHX Text 1/4"=1'-0"
AutoCAD SHX Text Checked By:
AutoCAD SHX Text Scale:
AutoCAD SHX Text Sheet
AutoCAD SHX Text Drawn By:
AutoCAD SHX Text
JC
AutoCAD SHX Text
REVISION:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
6JAN2021
AutoCAD SHX Text
PROJECT
AutoCAD SHX Text
TULSA I.A.P., OKLAHOMA
AutoCAD SHX Text
DETAILS
AutoCAD SHX Text
BCE: LT COL KURT STEPHENS
AutoCAD SHX Text 138th CIVIL ENGINEER SQUADRON
AutoCAD SHX Text
OKLAHOMA AIR NATIONAL GUARD TULSA I.A.P. OK.
AutoCAD SHX Text
DBCE: MAJ PATRICK DEERING