C-101.pdf
PDF 150 KB Posted
- Attached to
- Force Protection Repairs Federal contract opportunity
- Solicitation number
- W50S8U22B0004
- Issued by
- Department of the Army National Guard
About this file
This document contains a solicitation and site plan for force protection upgrades at an Air National Guard base. The Tulsa Air National Guard in Oklahoma is seeking a fixed-price contract to provide all labor, materials, equipment, and supervision necessary to upgrade force protection at its base in Tulsa. Services include fence and gate installations and repairs as depicted in the site plan. The project magnitude is between $100,000 and $250,000. This is a total small business set-aside with a NAICS code of 236220 and small business size standard of $39.5 million. Bids are due by an unspecified date in 2022, and award will be made if funding becomes available prior to September 30, 2022 to the responsible bidder offering the most advantageous price.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Attendance Sheet Bid opening Force Protection_Redacted.pdf | ||
| Abstract of Offers OF 1419 - Force Protection.pdf | ||
| W50S8U-22-B-0004-0001.pdf | ||
| Pre-Bid RFI Force Protection 25 May 22.pdf | ||
| Site Visit Sign In - Force Protection repairs Signed_Redacted.pdf | ||
| Site Visit Slides - Force Protection repairs.ppt | PPT presentation | |
| Site Visit Minutes - Force Protection repairs.pdf | ||
| 22-B-0004.pdf | ||
| Sliding Gate Drawing.pdf | ||
| C-501.pdf | ||
| RFI Template Force Protection Repairs.docx | DOCX document | |
| SOW - Force Protection v1.4.docx | DOCX document | |
| C-315-317_Redacted.pdf | ||
| A-501.pdf |
Show all 14
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CO
M
BA
A IR
M
AND
CO
M
T
EXISTING FENCE
BLDG 330
EXISTING GATE
NEW 4" POST AND
SWING GATE
NEW 5" CONC. W/ BUCKEYE
ULTRA FIBER 500
65.50'
8.00'
4.00'
EXISTING GATE
EXISTING DRAIN
TOP = 98.12
98.90
98.98
99.16
99.16
SAW CUT AT STREET EDGE
SAW CUT 2.00' FROM ASPHALT EDGE
SAW CUT 1.00' FROM ASPHALT EDGE
9" THICK CONC. WITH #4 REBAR AT 24" O.C.E.W.
9" THICK CONC. WITH #4 REBAR AT 24" O.C.E.W.
9" THICK CONC. WITH #4 REBAR AT 24" O.C.E.W.
SEE DETAIL D/A502
AutoCAD SHX Text
NORTH
AutoCAD SHX Text OKLAHOMA AIR NATIONAL GUARD - 138th FIGHTER WING
AutoCAD SHX Text
DEPARTMENT OF THE ARMY AND THE AIR FORCE
AutoCAD SHX Text
NATIONAL GUARD BUREAU - WASHINGTON,D.C.
AutoCAD SHX Text C-101
AutoCAD SHX Text of sheets
AutoCAD SHX Text
OF
AutoCAD SHX Text 1"=10'-0"
AutoCAD SHX Text Checked By:
AutoCAD SHX Text Scale:
AutoCAD SHX Text Sheet
AutoCAD SHX Text Drawn By:
AutoCAD SHX Text
JC
AutoCAD SHX Text
REVISION:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
6JAN2021
AutoCAD SHX Text
PROJECT
AutoCAD SHX Text
TULSA I.A.P., OKLAHOMA
AutoCAD SHX Text
BCE: LT COL KURT STEPHENS
AutoCAD SHX Text 138th CIVIL ENGINEER SQUADRON
AutoCAD SHX Text
OKLAHOMA AIR NATIONAL GUARD TULSA I.A.P. OK.
AutoCAD SHX Text
DBCE: MAJ PATRICK DEERING
AutoCAD SHX Text
BLDG 330 SWING GATE ADDITION
AutoCAD SHX Text 1" = 10'-0"
AutoCAD SHX Text A
AutoCAD SHX Text
FENCE / GATE LOCATIONS
AutoCAD SHX Text
LIMA TWO SITE PLAN
AutoCAD SHX Text 1" = 10'-0"
AutoCAD SHX Text B
File details come from the government source that posted it. Updated .