Amendment 0001A -Previous Assessment Report.pdf

PDF 4 MB Posted

Attached to
Tower Inspection and Engineering Evaluation of a ROHN Model 80 Series
Solicitation number
BX00050Y2026T
Issued by

About this file

Guyed Tower Maintenance and Condition Assessment Report

This document is a comprehensive maintenance and condition assessment report for a guyed tower located in Maynard, MA, conducted following the ANSI/TIA-222-G standard. The inspection evaluated the tower's structural integrity across multiple categories including structure condition, finish, lighting systems, grounding, antennas and lines, appurtenances, insulators, guys, concrete foundations, guyed mast anchors, and tower alignment.

The assessment identified several deficiencies requiring repair. Critical findings include: loose and missing bolts on guy pull-offs requiring replacement; rust and corrosion on B-leg flange at 70-ft and rigging block at 125-ft requiring steel brush cleaning and galvanizing compound application; climbing facilities lacking safety climb installation; inadequate guy tensions on multiple paths (Path A guy 1, Path B guys 1-2, and Path C guys 1 and 3R measured below acceptable tolerance ranges); disconnected grounding wire on Gamma guy requiring reconnection; loose lightning rod connection requiring tightening and installation of grounding wires; inadequate stabilizer arm and connection on antenna feed line; and surface corrosion on Beta anchor requiring treatment. Guy tension measurements detailed in Appendix A indicate that of the 11 measurable guy locations, four measured as "LOW" and one path's tensions could not be assessed due to ground-level insulators requiring crane assistance. Tower plumb and twist measurements in Appendix B confirm the structure remains within ANSI/TIA-222-G-2005 recommended limits for alignment and deflection across all reference elevations from 0-ft to 190-ft above concrete.

View the file

Other files

File Type Posted
Q and A.docx DOCX document
Amendment 0001A - Tower Pictures.docx DOCX document
2.2.1 RFQ - Tower Inspection.docx DOCX document
1.1.4 FRC Tower Inspection SOW.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Guyed Tower Maintenance and Condition Assessment Report

Maynard MA TIA Inspection

APPENDIX A: GUY TENSIONS

Table A-1

* Indicated guy tensions could not be checked due to insulators at the ground level. Tensions cannot be checked without the assistance of a crane.

Guy

Path

Guy #

Guy Size

(diameter in inches)

Measured

% Initial

Tension

-10% of Initial

Tension at 80°°°°F

(lbs)

+10% of Initial

Tension at 80°°°°F

(lbs)

Measured tension converted to 80°°F

(lbs)

Results

A

1 7/16 10 1870 2290 2000 OK

2* 1/2 -- -- -- -- --

3L* 1/2 -- -- -- -- --

3R* 1/2 -- -- -- -- --

B

1 7/16 10 1870 2290 1740 LOW

2 1/2 10 2420 2960 2200 LOW

3L 1/2 10 2420 2960 2430 OK

3R 1/2 10 2420 2960 2460 OK

C

1 7/16 10 1870 2290 1430 LOW

2 1/2 10 2420 2960 2670 OK

3L 1/2 10 2420 2960 2660 OK

3R 1/2 10 2420 2960 2210 LOW

APPENDIX B: TOWER PLUMB AND TWIST MEASUREMENTS

Table B-1: Tower Twist Measurements

Reference

Elevation

(above conc.)

Twist with

Respect

To Base (°°°°)

Allowable Twist with Respect

To Base (°°)

Relative Twist

Between Reference

Elevations (°°)

Allowable Twist

Between Reference

Elevations (°°)

T o w e r T w is t M e a su re m e n ts

190-ft 1.89 ±5.00 0.00

±2.65

183-ft 1.89 ±5.00 0.71

±3.00

130-ft 1.18 ±5.00 0.12

±1.00

70-ft 1.06 ±3.50 0.24

±0.75

50-ft 0.83 ±2.50 0.24

±0.75

35-ft 0.59 ±1.75 0.35

±1.00

20-ft 0.24 ±1.00 0.24

0-ft ± 0.00

Table B-2: Lateral Deflection Measurements

Reference

Elevation

(above conc.)

Resultant

Deflection (in)

Allowable

Resultant

Deflection (in) per TIA

Resultant Deflection

Between Reference

Elevations (in)

Allowable Deflection

Between Reference

Elevations (in) per TIA

T o w e r D e fl e ct io n

M e a su re m e n ts

190-ft 1.11 ±5.70

0.17 ±0.20

183-ft 0.95 ±5.50

0.458 ±1.60

130-ft 0.53 ±3.90

0.26 ±1.80

70-ft 0.62 ±2.10

0.10 ±0.60

50-ft 0.61 ±1.50

0.20 ±0.50

35-ft 0.44 ±1.05

0.46 ±0.50

20-ft 0.20 ± 0.60

0.20 ±0.60

0-ft 0.00 ± 0.00