Bay Pines VA Health Care System
Finishes & Fixtures
Standards http://upload.wikimedia.org/wikipedia/commons/0/03/US-DeptOfVeteransAffairs-Seal.jpg
Date of Issue: 2021 08 04
1 | P a g e
Finishes and Fixtures Standards
Table of Contents
Ceiling Finishes and fixtures Page 2-3
Ceiling tile
Paint
Restroom Finishes Page 3-4
Tile
Paint
Accessories
Door & Hardware Page 5-9
Door
Accessories & finishes
Notes Page 9-13
2 | P a g e
Ceiling Finishes and Light Fixtures:
Use Code no. Item No. Image
ACT C-1 Armstrong 1728 24”Wx
24”L x 5/8” Thick, Med;
fine Fissured
ACT Clean/Sterile C-2 Armstrong 868B 24”W x 24” L x 5/8” Thick;
smooth
Grid C-5 Armstrong PRELUDE
XL/XL HRC, .050 white, Fire Guard, 15/16” width
Gypsum Board
Ceilings
P-16
Ceiling Bright White
SW7007
Corridors, patient rooms, exam rooms
LT-1 Lithonia Lighting
2BZL2-30L-MVOLT-
SLD-LP830
Storage, supply, and offices
LT-2 Lithonia Lighting
EPANL 22 34L 40K 2x2
Flat Panel
Patient rooms and alcoves
LT-3 Lithonia Lighting
LDN6 6” round open and wallwasher
Patient rooms and alcoves
LT-4 Lithonia Lighting
LDN4 4” Round open and wallwasher
Restrooms LT-5 Lightology, Pipeline 2 vanity center feed with power 5w/foot
Finish: Satin Nickel
Various Lengths.
Color: 3000K
3 | P a g e
Finishes and Fixtures Standards
Wattage: 5W
MFR ID: P2WDP-5W-
C4R-34-30K-SN
ITEM #: EDG819081
Patient Room Lights LT-6 Modular Services
Company - Clarity overbed light fixture
Model # MDL-
C4LV22LEDT8120
Restroom Finishes:
All Water Closets
RR-8
American Standard Huron with
EverClean Back 1.28 - 1.6 gpf
EverClean Universal
Flushometer Toilet
Concealed Toilet flush valve
All Water Closets
RR-9
American Standard Selectronic
Sensor Operated Concealed
Toilet Flush Valve
606B-322. PK00.HAC hard-wired AC transformer single Lavatory
RR-10
Bradley Verge LVA Series, Finish Denali
Multi sink lavatory RR-11 Bradley Verge LVA Series, Finish Denali
All Lavatory
RR-12
American Standard Paradigm
Selectronic integrated proximity lavatory faucet.
Hard wired
All Urinals
RR-13
American Standard FloWise
Universal Urinal. 6590.001
4 | P a g e
All Urinals
RR-14
American Standard Sensor
Operated Urinal Flush Valve, Model number 6063.013.022
Shower Systems RR-15 American Standard
Commercial Shower Systems
2.5 GPM Shower System with
hand shower. 1662.221XV
Commercial Shower System
Kit
Eye Wash RR-16 Speakman SE-575-DP pull down eyewash
Water Fountain RR-17 Elkay EXH2O Bottle Filling
Station with Single ADA
Cooler Filtered 8 GPH Light
Gray Model: LMABF8WSLK
Toilet Partitions RR-18 Hiny Hiders
Color Linen
Strikes: 3” stainless steel emergency access
Stirrup Brackets – Stainless steel double ear, Latches – occupancy indicator, Hinges-
Stealth integral hinge
5 | P a g e
Door & Hardware Finishes:
Use Code no. Item No. Image
Door frame guards F-1 InPro Custom Form Door
Frame: .040” (1mm) thick rigid vinyl
Standard Heights: 3’
(.91m), 4’ (1.22m), 8’
(2.44m)
Door edge protector E-2 InPro Stainless Steel Door
Edge Protector
• Styles: L-Shaped & U-
Shaped
• Standard Heights: 3’
(.91m), 8’ (2.44m)
Astragal AS-1 National Guard 553 beveled edge astragal set on active leaf. Stainless steel. To be installed on all double doors.
Door edge protector E-1 InPro Stainless Steel Door
Edge Protector
96” Full Height
Kickplate K-1 InPro Stainless Steel
Kickplate: Custom Form
Door, standard type 430, 16 gauge
Kickplate Heavy Use
Areas
K-2 Palladium Kickplate
.060” Custom Form
6 | P a g e
Doors – all new doors
D-1 Marshfield Door Systems:
Durable Door: Color- Riga
Birch
Doors – Fire Doors D-2 Mesker metal doors and frame
Healthcare Occupancy
Office Lock
H-1
Corbin-Russwin ML2051 series Function: Lock is always open on inside, locked by button on inside.
Storeroom Lock
H-2
Corbin-Russwin ML2057 series Function: always locked on outside, always open inside, key retract latch bolt
Bathroom Privacy
Lock
H-3
Corbin-Russwin ML2030 series Function: Bathroom lock, button locks from inside, square stock key or thumb latch unlocks. It will be left unlocked upon leaving room.
Passage Set
H-4
Corbin-Russwin ML2010 series, Function: Passage.
Two levers, always unlocked.
7 | P a g e
Business Occupancy
Classroom Lock
H-5
Corbin-Russwin ML2055 series, Function: always open inside, can be locked and unlocked outside with key
Office Lock
H-6
Stanley QCL151 series, Sierra handle, Function:
Turn/push-button locking;
pushing and turning button locks outside lever, requiring use of key until button is manually unlocked. Push-button locking; pushing button locks outside lever until unlocked by key or by depressing inside lever.
Clutch feature disengages outside lever from latch when locked to prevent vandalism. Inside lever is always free for immediate egress. (Image for reference only)
Storeroom Lock
H-7
Stanley QCL171 series, Sierra handle, Function:
Outside lever always locked. Entrance by key only. Inside lever unlocked and free for immediate egress. Clutch feature disengages outside lever from latch when locked to prevent vandalism.
(Image for reference only)
Bathroom Privacy
Lock
H-8
Stanley QCL140 series, Sierra handle, Function:
Push-button locking. Can be opened from outside with a small screwdriver.
Turning inside lever or closing door releases button.
Inside lever is always free
8 | P a g e
Finishes and Fixtures Standards for immediate egress.
Clutch feature disengages outside lever from latch when locked to prevent vandalism. (Image for
Passage Set
H-9
Stanley QCL130 series, Sierra handle, Function:
Both levers always unlocked and always free for immediate ingress & egress. (Image for
Classroom Lock
H-10
Stanley QCL161 series, Sierra handle, Function:
Key required to either lock or unlock outside lever.
Inside lever is always unlocked and free for immediate egress. Clutch feature disengages outside lever from latch when locked to prevent vandalism. (Image for
Electrical
Combination Lock
H-11
Schlage Cobra pushbutton lock. Model: CO-100M.
The lock must comply with our 7-pin small format best cylinders.
Electrical
Combination Lock
H-12
Schlage Cobra pushbutton lock. Model: CO-100C.
The lock must comply with our 7-pin small format best cylinders.
Exit Hardware
H-13
Von Duprin 99 series, surface mounted.
Generally, storeroom function preferred; when hardware needs to be left unlocked it can be dogged down
9 | P a g e
Notes
Door Closure H-14 IR/LCN Series 4040 super smoothie. Function ADA compliance and heavy-duty use.
Door Closure H-15 IR/LCN Series 4041XP hold opens.
Door Hinge H-16 Hager CB1191 Concealed
Bearing -
Standard Weight, Non-rising removable pin with button tip and plug
Door Hinge H-17 Hager 780 Series –
Concealed leaf
Door Laminate DL-1 Wilsonart Laminate Riga
Birch
• All Healthcare Occupancy locks should be mortise style.
• All Business Occupancy locks can be cylindrical
• Where key locks are required, these locks shall conform to the lock cylinders currently in use.
The locks must accept a Medco 7-pin interchangeable core. The industry nomenclature is “I/C small format 7 pin core”. Vendor shall provide 1 core and 7 keys per lockset where cores are required.
10 | P a g e
Finishes and Fixtures Standards
• Door locks used throughout this installation are of two types: cylindrical and mortise. Mortise locks are preferred.
• Exit Hardware used on this station must also accept the Best cylinders. It should be surface mounted, and not mortise style. Vertical locking rods, when used, must also be surface mounted. Guards must be provided.
• All double doors shall have manual flush bolts.
• For door closers, it is recommended to use IR/LCN heavy-duty.
• All electrical conduits shall be a minimum of 3/4" diameter.
• Signal cables shall be routed in cable tray or conduits, minimum of 3/4" diameter.
• All building control systems shall be Johnson Controls Metasys. All work will be integrated into the existing Metasys system, including updating all graphics and programming. Utilize sole-source procurement for building controls.
• All electrical distribution panels shall be Square D electrical equipment.
• All electrical distribution panels shall be labeled with its power source information (circuit feeding it). Arc Flash labels will be added to comply with code requirements.
• Label the cover plates of all electrical receptacles both inside and outside with their circuit numbers (on the outside of the receptacle cover and a label inside the outlet box).
• The A/E shall prepare the bid documents to ensure the inclusion of the applicable safety and infection control measures per the VA Construction Safety policy, and as a result of formal construction safety risk assessments conducted by VA staff.
• Incorporate contractor’s staging areas into the plan sheets for storage, heavy equipment and cranes, if applicable. Contractor parking will be limited to within fenced staging areas only.
• Design penetrations of fire and smoke rated partitions to utilize manufacturer’s products that are able to accept additional cables without removing firestopping materials. Example: EZ-
Path® Fire Rated Pathways.
• All fire stopping caulking/putty shall be red in color.
• All access panel for fire/smoke dampers shall be 24" x 24" in diameter with clear access.
• All Fire /Smoke Dampers shall be identified and labeled on drawings
• All fire Alarm horn/strobes shall be red in color and be mounted on walls
• All fire Alarm control panels shall be Simplex brand and capable of voice announcements.
• All Exit lights shall be LED Green in color self-diagnostic testing. Battery backup is not allowed.
11 | P a g e
* Salient Characteristics for high use areas which require personal protective equipment.
Material: Rubber compound with abundant natural fillers and environmentally compatible color pigments
Surface: Smooth
Color: Tone-on-tone color visual
Roll Size: 0.12 inches (3mm high foot traffic or 2mm) thickness,
39.37 feet by 48 inches (12m by 1.22m)
Back of Roll: Smooth, double-sanded back
Homogeneous: Yes, mottled, single durometer
Limited Wear Warranty: 5 years
Hardness: ASTM D2240, Shore type A, required ≥ 75
Static Load: Per ASTM F970 Standard Test Method for Static Load
Limit, residual compression, when tested with 800 lbs, ≤
0.005”
ISO 14001: Manufacturer shall be ISO 14001 Environmental
Management Systems Certified
PVC Free: Products shall contain no polyvinyl chloride
Abrasion Resistance: Taber abrasion test, ASTM D3389, H-18 wheel, 500 gram load, 1000 cycles, gram weight loss ≤ 0.4
Slip Resistance: Static coefficient of friction (James Test): ASTM D2047, ≥ 0.5
Bacteria Resistance: Products shall be resistant to bacteria, fungi, and micro-organism activity, according to ASTM E2180 and ASTM
G21
Halogen Free: Products shall contain no halogens
Sound Absorption: ISO 140-8 Footfall Sound Absorption, 8 dB
Burn Resistance: Cigarette and solder burn resistance
Flammability: ASTM E648; NFPA 253; NBSIR 75 950, ≥ 0.45 watts per square centimeter, Class 1
Smoke Density: ASTM E662, NFPA 258, NBS smoke density, < 450
Asbestos Free: Products shall contain no asbestos
Non Hazardous: Flooring shall be made without any chemicals that may be hazardous or containing any teratogenic, mutagenic or any other ingredients known to be carcinogenic
• All fire extinguisher cabinets shall be fully recessed mounted, non-locking, capable of holding a 4A-60BC fire extinguisher. (TIL- Section 10 44 13) Install cabinet so that bottom of cabinet is 914 mm (36 inches) above finished floor.
• All Smoke/Fire Walls shall have a 4" tall stenciled on both sides of the entire wall with the rating of the wall above the ceiling. Space markings at 10 feet intervals.
• All door closers shall have hold open feature unless specifically not required.
• All egress lights shall be LED in style and wall mounted.
• New equipment shall be assessed for lockout-tagout requirements, and have a procedure written and added to the Bay Pines VAHCS LOTO database.
12 | P a g e
Finishes and Fixtures Standards
Cleaning: Flooring surface shall have the ability to be cleaned and maintained without the use of any chemicals that may be hazardous or containing any teratogenic, mutagenic or any other ingredients known to be carcinogenic. Manufacturer shall make available a cleaning system that effectively cleans the flooring surface using water, cleaning pads and a suitable cleaning machine, without the use of factory and/or field-applied coatings.
Shine: Higher shine surfaces can be achieved by dry buffing without any artificial topical applied coatings
Stain Resistance: Resistant to stains from healthcare related disinfectants and chemicals to include but not limited to rust, Betadine, Methylene Blue, Alcohol based hand sanitizer.
Manufacturer to provide samples for testing without manually or mechanically applied coatings, sealers or floor finish on the test sample.
Indoor Air Quality: Flooring shall be GREENGUARD Gold certified for indoor air quality
Installation: Flooring installers must be manufacturer-approved
Adhesive: Water-based acrylic adhesive must be low VOC (volatile organic compound) and resistant to 85% relative humidity
Millwork Standards
Millwork must be commercial grade quality and follow below premium guidelines.
Warranties are required by the Manufacturer.
Use Premium grade laminate millwork.
• HPL (high pressure laminate), nominal 0.7 mm thick
• blend and match continuous pattern (material permitting).
• Semi exposed parts not including backs of flush doors to be HPL 0.7mm thermoset overlay, any paper or particle board must be sealed or painted or paper impregnated overlay. Concealed parts, mill option.
• Premium grade direction matching (dependent on finish selected)
• Balanced construction for unrestrained components, shall contain an odd number of layers with the substrate forming the inner core layer. Same machine direction on double sided substrate components.
• Hot melt applied HPL edge banding shall be primed before application for proper adhesion unless the hot melt adhesive used has been specially formulated for HPL without requiring pre-application of a primer. Edge-bands to the extent of standard length of materials, must run the full length of a single vertical or horizontal member without a joint or splice. Finish all front edges of cases with a single piece of laminate, without joints at the corners. Thermally fused and wrapped.
• Toe kicks chamfer the lower edge for durability. Use concealed 35 mm cup hinges; adjustable metal shelves must be recessed and multiple min. 5mm diameter, dual pin holes provided.
• Joinery, case body members: Tops, exposed ends, and bottoms (finished ends on casework shall be integral, not applied secondarily) Any fasteners will not be visible on any exposed or semi-
13 | P a g e
Finishes and Fixtures Standards exposed parts; exposed end corner details and face frame attachment shall use a fully concealed interlocking mechanical system
• Cabinet backs – Floor Standing, side bound, captured in grooves; securely fastened to top and bottom, Full overlay, plant-on backs: min. 12.7mm (1/2”) thick attached with min #8 low root, high thread (not drywall) screws spaced max. 200mm (8”) on center. Edge of back shall not be exposed on finished ends.
• Gap tolerances: doors, panels, frames, door to door is 3.2mm (1/8”) horizontal in vertical alignment tolerance 0.8mm (1/32”) Max variation in flushness of adjacent doors 0.8m (1/32”), Flatness of exposed case doors max deviation and between factory assemble joints .13mm
(.005”), between fixed exposed components .4mm (1/64”) max gap between each end of adjustable shelf and case side 1.6mm (1/16”).