BEQ HP285 FLRPLN.pdf
PDF 887 KB Posted
- Attached to
- BEQ HP200 Area Paint & Flooring Repairs
- Solicitation number
- N4008526R9055
About this file
This document is a set of architectural drawings for major interior and exterior repairs to Building HP 285 at Marine Corps Base Camp Lejeune, North Carolina, under contract N40085-06-B-0059. The project, prepared by Kanoy Architecture, P.A., consists of comprehensive demolition and renovation work across all three floors of a barracks-style facility containing multiple sleeping units, common areas, mechanical rooms, and support spaces.
The demolition scope includes removal of existing wood wall lockers, all doors and frames (except specific toilet room frames and chase doors), windows, ceramic tile showers, vanities, sinks, ceiling systems, mailboxes, and utility fixtures. Specific work involves demolishing approximately 40,000 square feet of vinyl composition tile (VCT) and mastic throughout the building, removing lay-in ceiling tile and grid systems, installing solid panels on mechanical room doors, and creating new openings through roofs and floors for vertical ductwork related to closet exhaust systems. The drawings document asbestos-containing materials identified in floor tile mastic (40,000 square feet, non-friable), parapet wall tar on the exterior roof (1,500 square feet, non-friable), and penetration mastic on the exterior roof (200 square feet, non-friable). Additionally, the contractor is required to photograph, tag, catalog, remove, store, and protect all existing furniture and mirrors, then reinstall the furniture upon project completion while offering wardrobes to the government for potential reuse or disposal.
View the file
Other files
Show all 20
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
IS
TE
R E
G E
R
R A
RPO
T
H
N.
I
D
AR
C
T
I
E
N
CTURAL
OC
O
C.N
AN
ORT H CA RO
IL
CERT. NO.K
A
N
OY
ARCH TE T
P .A
C URE,
I
50372
C
N.R
CRA
ERED
T
R E
G
IS
C E
T T
HI
N
O
RT H CA OLIN
A
A
K
COB A
Y
ON
J
S.
W
TSE
END,
W
EST E ND,
A
2 3 4
B
C
D
E
OF:
DATE:
DATE:APPROVED: PWO OR OICC
APPROVEDDESCRIPTIONSYM. DATE
DEPARTMENT OF THE NAVY
DESIGNED BY:
CHECKED BY:
80091
CODE IDENT NO
SATISFACTORY TO:
CAMP LEJEUNE, NORTH CAROLINA
SIZE
DESIGN DIR.:
NAVFAC DRAWING NO.
SUBMITTED BY:
DRAWN BY:
NAVAL FACILITIES ENGINEERING COMMAND
F
SCALE: SHEETSPEC.
Kanoy Architecture, P.A.
CONST. CONTR. NO.
OF
MARINE CORPS BASE
REVISIONS
GRAPHIC
JSK
1995A Juniper Lake Road West End, North Carolina 27376
Fax 910-215-5885
ADB
ADB
ADB
SHEET A3,A4.A5 09/24 JSK
MAJOR INTERIOR/EXTERIOR
REPAIRS TO BUILDING HP 285
N40085-06-B-0059
3205-06-0059
ARCHITECTS MASTER PLANNERSPROGRAMMERS
Phone 910-215-5885
287'-2"
'-4
LA
U
N D
R Y
LOUNGE
LA
U
N D
R Y
LOUNGE
CHASE
SLEEPING ROOMS SLEEPING ROOMS
SLEEPING ROOMS SLEEPING ROOMS
SLEEPING ROOMS SLEEPING ROOMS
SLEEPING ROOMS SLEEPING ROOMS
SLEEPING ROOMS SLEEPING ROOMS
SLEEPING ROOMS SLEEPING ROOMS
SLEEPING ROOMS SLEEPING ROOMS
SLEEPING ROOMS SLEEPING ROOMS
SLEEPING ROOMS SLEEPING ROOMS
SLEEPING ROOMS SLEEPING ROOMS
SLEEPING ROOMS SLEEPING ROOMS
SLEEPING ROOMS SLEEPING ROOMS
SLEEPING ROOMS SLEEPING ROOMS
SLEEPING ROOMS SLEEPING ROOMS
SLEEPING ROOMS SLEEPING ROOMS
SLEEPING ROOMS SLEEPING ROOMS
ENTRY
OFFICE
MECH.
RM
TLT.
M E
C H
R M
MECH.
RM
TLT.
CHASE
S T
O R
A G
E
C O
R R
ID
O
R C
O R
R
ID
O R
CHASE
M E
C H
R M
.CHASE
CHASE
M E
C H
R M
.CHASE CHASE
M E
C H
R M
.CHASE
REMOVE ABOVE VENTILATION GRILL FROM ALL MECH ROOM DOORS. INSTALL A
SOLID PANEL TO MATCH THE COLOR OF THE DOORS.
DEMOLITION KEY NOTES
NOT USED
DEMO EXISTING MAILBOXES LOCATED INCORRIDORS OF
COMMON AREA. PREPARE OPENING FOR NEW BRICK TO FILL HOLE.
REMOVE PAPER TOWEL AND TRACH DISPENSER OUT OF PUBLIC TLT. IN
COMMON AREAS. ALL THREE FLOORS. (TYP 1 PER FLOOR.)
PATCH AND PREP ALL PAINTED SURFACES FOR NEW PAINT.
EXISTING PAINTED WALLS INCLUDE:
DEMO ALL EXISTING WOOD WALL LOCKERS IN SLEEPING
ROOMS.
ALL SLEEPING ROOM WALLS.
ALL LOUNGE WALLS.
ALL OFFICE WALLS.
ALL STAIR WALLS.
ALL STORAGE ROOM WALLS.
ALL TOILET WALLS.
ALL LAUNDRY ROOM WALLS.
ALL CEILINGS.
REMOVE 1ST FLOOR 5'-4" x 8'-8" WINDOW IN COMMON AREA
ENTRY OFFICE.
G.C. TO PROVIDE OPENINGS THROUGH ROOF AND 2ND & 3RD FLOORS IN
CHASE FOR VERTICAL DUCTWORK FOR NEW CLOSET EXHAUST SYSTEM.
VERIFY WITH HVAC CONTR.. (TYPICAL ONE PER 4 ROOMS)
DEMO EXISTING LAY-IN CEILING TILE & GRID TO INCLUDE BUT NOT
LIMITED TO: CEILING TILE, SUSPENSION SYSTEM, WIRES, HANGERS, ETC.
SEE FINISH SCHEDULE FOR LOCATIONS.
DEMO EXISTING GYP. BD CLG. IN CLOSET AND VANITY AND TOILET
AREAS. DEMO EXISTING METAL CEILING JOIST AND EXISTING
ACCESS PANEL. (SHADED AREA SHOWN IS CEILING TO BE REMOVED)
REMOVE TOWEL BARS IN SLEEPING UNIT BATHROOMS.
REMOVE TOILET TISSUE DISPENSERS IN ALL BATH UNITS TO INCLUDE
TLT. ROOMS IN COMMON AREAS. (Surface Mounted)
DEMO ELECTRIC WATER COOLERS.
DEMO ALL EXISTING H.M. DOORS & FRAMES AND WINDOWS AND ALL
WALL AND FLOOR STOPS AND HOLDERS. EXCEPT TOILET ROOM
DOOR FRAMES IN SLEEPING UNITS AND INTERIOR/EXTERIOR CHASE DOOR
FRAMES. TO INCLUDE ALL WINDOW TREATMENT, AND HARDWARE. PREPARE OP
FOR NEW WORK.
PLUMBING DRAWINGS FOR ADDITIONAL INFO.
DEMO ALL CERAMIC TILE SHOWERS, WALLS, AND FLOOR COMPLETE
TO SUBSTRATE. INCLUDE CERAMIC TILE, SHOWER VALVES, SHOWER PANS,
AND DRAINS AND ACCESSORIES. CLEAN AND PREPARE SHOWERS, WALLS
AND FLOORS THROUGH OUT ENTIRE BATHROOM, FOR NEW FINISH.
DEMO DOOR AND HARDWARE IN TOILET ROOMS LOCATED IN
SLEEPING ROOMS. INCLUDE DOORS AND HARDWARE TO
TOILET.
REMOVE PUBLIC TELEPHONE ENCLOSURES AND ANY
RELATED HARDWARE. (TYP 2 PER FLOOR, LOCATED IN
CORRIDOR OF COMMON AREAS.) DO NOT DISTURB THE
PHONE SYSTEM.
G.C. TO PROVIDE OPENING THROUGH ROOF AND 2ND & 3RD FLOOR IN MECH.
ROOMS. COORDINATE LOCATIONS & SIZES WITH HVAC CONTR. SEE DRAWING
M-4 FOR ADDITIONAL DETAILS. (TYPICAL 1 PER MECH. ROOM.)
G.C. TO PROVIDE OPENING THROUGH CMU CHASE WALL FOR 4"X6"
MECH. DUCT FOR NEW CLOSET EXHAUST SYSTEM. (TYPICAL ONE PER ROOM)
COORDINATE LOCATIONS & SIZES WITH HVAC CONTR..
20 DEMO ALL CHASE ENTRANCE DOORS AND HARDWARE. LEAVE EXISTING FOUR
SIDED FRAME.
DEMO EXISTING VCT AND MASTIC TO SUBSTRATE THROUGH OUT ENTIRE
BUILDING. CLEAN AND PREPARE SLAB FOR NEW FINISH. SEE EXISTING FINISH
SCHEDULE. SEE ASBESTOS SCHEDULE FOR LOCATIONS OF ASBESTOS MATERIAL.
VCT AND MASTIC AS BEEN FOUND TO CONTAIN ASBESTOS.
DEMO VANITIES AND SINKS IN ALL SLEEPING ROOMS AND WALL HUNG
SINKS IN COMMON AREA. SEE PLUMBING DRAWINGS
FOR ADDITIONAL WORK. REMOVE MIRROR AND PREPARE WALL FOR NEW.
ASBESTOS CONTAINING MATERIALS KEYNOTES
LEAD BASE PNT. CONTAINING MATS. KEYNOTES
-NO LEAD PAINT HAS BEED DETECTED:
-THE FOLLOWING ITEMS HAVE BEEN FOUND TO HAVE ASBESTOS:
-ALL FLOOR TILE MASTIC (THROUGHOUT) 40,000SF -NON-FRIABLE
-PARAPET WALL TAR (EXTERIOR ROOF) 1500SF-NON-FRIABLE
-PENETRATION MASTIC (EXTERIOR ROOF) 200SF-NON-FRIABLE
The contractor shall photograph, tag, and record the location each piece of furniture in the building.
The contractor shall remove each piece of furniture and mirrors from the building. The contractor shall store and protect the furniture from damage. The contractor shall place the furniture back in the building with exception of the wardrobes. The contractor shall offer the wardrobes to the government. If the government refuses the wardrobes, the contractor shall dispose of the wardrobes. The contractor shall provide an electronic copy of the furniture condition pictures and furniture locations to the government on CD.
A-1
A
A
DEMO FLOOR PLAN
A
A
A
A
A
A
3/32" = 1'-0"
3/32" = 1'-0"
2ND & 3RD FLOOR DEMO KEY PLAN
FIRST FLOOR DEMO KEY PLAN 1
A1
A1
60002089
IS
TE
R E
G E
R
R A
RPO
T
H
N.
I
D
AR
C
T
I
E
N
CTURAL
OC
O
C.N
AN
ORT H CA RO
IL
CERT. NO.K
A
N
OY
ARCH TE T
P .A
C URE,
I
50372
C
N.R
CRA
ERED
T
R E
G
IS
C E
T T
HI
N
O
RT H CA OLIN
A
A
K
COB A
Y
ON
J
S.
W
TSE
END,
W
EST E ND,
A
2 3 4
B
C
D
E
OF:
DATE:
DATE:APPROVED: PWO OR OICC
APPROVEDDESCRIPTIONSYM. DATE
DEPARTMENT OF THE NAVY
DESIGNED BY:
CHECKED BY:
80091
CODE IDENT NO
SATISFACTORY TO:
CAMP LEJEUNE, NORTH CAROLINA
SIZE
DESIGN DIR.:
NAVFAC DRAWING NO.
SUBMITTED BY:
DRAWN BY:
NAVAL FACILITIES ENGINEERING COMMAND
F
SCALE: SHEETSPEC.
Kanoy Architecture, P.A.
CONST. CONTR. NO.
OF
MARINE CORPS BASE
REVISIONS
GRAPHIC
JSK
1995A Juniper Lake Road West End, North Carolina 27376
Fax 910-215-5885
ADB
ADB
ADB
SHEET A3,A4.A5 09/24 JSK
MAJOR INTERIOR/EXTERIOR
REPAIRS TO BUILDING HP 285
N40085-06-B-0059
3205-06-0059
ARCHITECTS MASTER PLANNERSPROGRAMMERS
Phone 910-215-5885
6'-7 1/2"±
4' -1
0"
'-4
5'-4"
8'-8"
'-0
8'-8"
9' -2
6'
-2
9' -0
33'-4"
17'-4"±
4'-8"
93 4
DROPPED SOFFIT AREA.
ENTRY
OFFICE
LAUNDRY
STORAGE
MECH RM.
T.L.T.
W
W
W
D
DD
D
LOUNGE
VENDING
AREA
STAIR
WELL
2 20
16 16
C O
R R
ID
O
R
9' -0
5'-8"
4' -8
6'
-2
'-6
'-0
32'-6"±
5'-4"
17'-4"±
4'-8"±
8'-8"±
9' -0
8'-8"
LOUNGE
MECH RM.
3RD FLOOR
ROOF HATCH
C O
R R
ID
O
R
OFFICE
LAUNDRY
STORAGE
93 4
T.L.T.
W
W
W
D
DD
DSTAIR
WELL
'-6
14'-0"±
28'-8"
6'-6" 6'-6"
5' -8
14'-0"
EXISTING CMU OPENING
SLEEPING UNITS
LAVITORY
11 11
LAVITORY
SEE NOTES ON OPPSISTE
SIDE.
SLEEPING UNITS
SEE NOTES ON OPPSISTE
SIDE.
EXISTING CMU OPENING
6 6
SLEEPING UNITS
SLEEPING UNITS
LINE OF GYP. BD. BULKHEAD ABOVE
CONC. CLG.
13 13
GYP BD CLG
4 4
10 10
A10 A2
REMOVE ABOVE VENTILATION GRILL FROM ALL MECH ROOM DOORS. INSTALL A
SOLID PANEL TO MATCH THE COLOR OF THE DOORS.
DEMOLITION KEY NOTES
NOT USED
DEMO EXISTING MAILBOXES LOCATED INCORRIDORS OF
COMMON AREA. PREPARE OPENING FOR NEW BRICK TO FILL HOLE.
REMOVE PAPER TOWEL AND TRACH DISPENSER OUT OF PUBLIC TLT. IN
COMMON AREAS. ALL THREE FLOORS. (TYP 1 PER FLOOR.)
PATCH AND PREP ALL PAINTED SURFACES FOR NEW PAINT.
EXISTING PAINTED WALLS INCLUDE:
DEMO ALL EXISTING WOOD WALL LOCKERS IN SLEEPING
ROOMS.
ALL SLEEPING ROOM WALLS.
ALL LOUNGE WALLS.
ALL OFFICE WALLS.
ALL STAIR WALLS.
ALL STORAGE ROOM WALLS.
ALL TOILET WALLS.
ALL LAUNDRY ROOM WALLS.
ALL CEILINGS.
REMOVE 1ST FLOOR 5'-4" x 8'-8" WINDOW IN COMMON AREA
ENTRY OFFICE.
G.C. TO PROVIDE OPENINGS THROUGH ROOF AND 2ND & 3RD FLOORS IN
CHASE FOR VERTICAL DUCTWORK FOR NEW CLOSET EXHAUST SYSTEM.
VERIFY WITH HVAC CONTR.. (TYPICAL ONE PER 4 ROOMS)
DEMO EXISTING LAY-IN CEILING TILE & GRID TO INCLUDE BUT NOT
LIMITED TO: CEILING TILE, SUSPENSION SYSTEM, WIRES, HANGERS, ETC.
SEE FINISH SCHEDULE FOR LOCATIONS.
DEMO EXISTING GYP. BD CLG. IN CLOSET AND VANITY AND TOILET
AREAS. DEMO EXISTING METAL CEILING JOIST AND EXISTING
ACCESS PANEL. (SHADED AREA SHOWN IS CEILING TO BE REMOVED)
REMOVE TOWEL BARS IN SLEEPING UNIT BATHROOMS.
REMOVE TOILET TISSUE DISPENSERS IN ALL BATH UNITS TO INCLUDE
TLT. ROOMS IN COMMON AREAS. (Surface Mounted)
DEMO ELECTRIC WATER COOLERS.
DEMO ALL EXISTING H.M. DOORS & FRAMES AND WINDOWS AND ALL
WALL AND FLOOR STOPS AND HOLDERS. EXCEPT TOILET ROOM
DOOR FRAMES IN SLEEPING UNITS AND INTERIOR/EXTERIOR CHASE DOOR
FRAMES. TO INCLUDE ALL WINDOW TREATMENT, AND HARDWARE. PREPARE OPENING
FOR NEW WORK.
PLUMBING DRAWINGS FOR ADDITIONAL INFO.
DEMO ALL CERAMIC TILE SHOWERS, WALLS, AND FLOOR COMPLETE
TO SUBSTRATE. INCLUDE CERAMIC TILE, SHOWER VALVES, SHOWER PANS,
AND DRAINS AND ACCESSORIES. CLEAN AND PREPARE SHOWERS, WALLS
AND FLOORS THROUGH OUT ENTIRE BATHROOM, FOR NEW FINISH.
DEMO DOOR AND HARDWARE IN TOILET ROOMS LOCATED IN
SLEEPING ROOMS. INCLUDE DOORS AND HARDWARE TO
TOILET.
REMOVE PUBLIC TELEPHONE ENCLOSURES AND ANY
RELATED HARDWARE. (TYP 2 PER FLOOR, LOCATED IN
CORRIDOR OF COMMON AREAS.) DO NOT DISTURB THE
PHONE SYSTEM.
G.C. TO PROVIDE OPENING THROUGH ROOF AND 2ND & 3RD FLOOR IN MECH.
ROOMS. COORDINATE LOCATIONS & SIZES WITH HVAC CONTR. SEE DRAWING
M-4 FOR ADDITIONAL DETAILS. (TYPICAL 1 PER MECH. ROOM.)
G.C. TO PROVIDE OPENING THROUGH CMU CHASE WALL FOR 4"X6"
MECH. DUCT FOR NEW CLOSET EXHAUST SYSTEM. (TYPICAL ONE PER ROOM)
COORDINATE LOCATIONS & SIZES WITH HVAC CONTR..
20 DEMO ALL CHASE ENTRANCE DOORS AND HARDWARE. LEAVE EXISTING FOUR
SIDED FRAME.
DEMO EXISTING VCT AND MASTIC TO SUBSTRATE THROUGH OUT ENTIRE
BUILDING. CLEAN AND PREPARE SLAB FOR NEW FINISH. SEE EXISTING FINISH
SCHEDULE. SEE ASBESTOS SCHEDULE FOR LOCATIONS OF ASBESTOS MATERIAL.
VCT AND MASTIC AS BEEN FOUND TO CONTAIN ASBESTOS.
DEMO VANITIES AND SINKS IN ALL SLEEPING ROOMS AND WALL HUNG
SINKS IN COMMON AREA. SEE PLUMBING DRAWINGS
FOR ADDITIONAL WORK. REMOVE MIRROR AND PREPARE WALL FOR NEW.
ASBESTOS CONTAINING MATERIALS KEYNOTES
LEAD BASE PNT. CONTAINING MATS. KEYNOTES
-NO LEAD PAINT HAS BEED DETECTED:
-THE FOLLOWING ITEMS HAVE BEEN FOUND TO HAVE ASBESTOS:
-ALL FLOOR TILE MASTIC (THROUGHOUT) 40,000SF -NON-FRIABLE
-PARAPET WALL TAR (EXTERIOR ROOF) 1500SF-NON-FRIABLE
-PENETRATION MASTIC (EXTERIOR ROOF) 200SF-NON-FRIABLE
7' -0
2"
1' -4
2"
2" 5'-4"2" 3'-0"
8'-8"
8' -8
REMOVE PORITION OF CMU/BRICK
MASONRY WALL. TYPICAL TO ALL.
EXISTING BRICK COLUMN REMAINS.
TYPICAL.
REMOVE EXISTING STEEL FRAME . INCLUDED
IN STEEL FRAME TO BE REMOVED:
WINDOW, DOOR,AND ALL WINDOW TREATMENTS.
PREPARE REMAINING OPENING FOR NEW
WALL INSTALLATION.
The contractor shall photograph, tag, and record the location each piece of furniture in the building.
The contractor shall remove each piece of furniture and mirrors from the building. The contractor shall store and protect the furniture from damage. The contractor shall place the furniture back in the building with exception of the wardrobes. The contractor shall offer the wardrobes to the government. If the government refuses the wardrobes, the contractor shall dispose of the wardrobes. The contractor shall provide an electronic copy of the furniture condition pictures and furniture locations to the government on CD.
A-2
1/4" = 1'-0" 05 10
A2A1
1/4" = 1'-0" 05 10
A2A1
1/4" = 1'-0" 05 10
A2A1
1/4" = 1'-0" 05 10
A2A1
TYPICAL DEMO PLAN
DOOR AND WINDOW FRAMES 4
1/2" = 1'-0" 0 51
A1 A2
A2
5EXIST.WINDOW & DOOR ELEV.
TYPICAL SLEEPING UNIT DEMO TYPICAL SECOND AND THIRD
COMMON AREA DEMO PLAN
FIRST FL. COMMON AREA DEMO
DEMO PLAN TYP. ROOM
A2
60002090
File details come from the government source that posted it. Updated .