26M087CN BEQ HP200 Area Paint-Flooring Project PS.pdf

PDF 51 KB Posted

Attached to
BEQ HP200 Area Paint & Flooring Repairs
Solicitation number
N4008526R9055
Issued by

About this file

This document is a finishes specification schedule for a federal construction project under NAVFAC oversight. It establishes approved basis-of-design products for interior finishes, including paint, flooring, and related materials, with specific manufacturers and models identified for color, pattern, texture, and salient characteristics.

The specification requires Benjamin Moore paints for primary walls (1548 Classic Gray) and sleeping rooms (1552 River Reflections), Sherwin Williams for door frames (SW 7026 Griffin) and GWB/exposed ceilings (SW 7102 White Flour). Flooring materials include Mannington luxury vinyl tile for sleeping rooms (Crisscross Zoom Charcoal) and offices (Access Stone Linear Stone Shale), with Johnsonite rubber base (283 Toast) and Schluter transition strips (Reno-U AEU 35 and AEU 100, satin anodized). Epoxy resinous flooring specified for lounge and shared spaces uses Dur-A-Flex Dur-A-Quartz (Q28-23). Inpro Type 430 stainless steel corner guards are required for outside corners, and a wall graphic ("Find Your Level") is specified for the lounge in Lindsey II Beige. The general notes clarify that listed manufacturers represent approved basis of design only; equivalent products meeting specified criteria are acceptable if reviewed by the project manager and approved by the NAVFAC Contracting Officer. The contractor bears responsibility for timely material ordering to prevent delays and must install all materials per manufacturer requirements, ensure all interior finishes in exit ways meet minimum Class A rating, spray paint electrical panels and access panels to match adjacent wall colors, and ensure all flooring transitions comply with ABA guidelines with transitions under doors centered.

View the file

Other files

Show all 20

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

NAME LOCATION MANUFACTURER MODEL COLOR SIZE

PAINT PRIMARY WALLS BENJAMIN MOORE 1548 CLASSIC GRAY -

ACCENT PAINT SLEEPING ROOMS BENJAMIN MOORE 1552 RIVER REFLECTIONS -

PAINT DOOR FRAMES SHERWIN WILLIAMS SW 7026 GRIFFIN -

PAINT GWB & EXPOSED CEILINGS SHERWIN WILLIAMS SW 7102 WHITE FLOUR -

WALL GRAPHIC LOUNGE FIND YOUR LEVEL LINDSEY II BEIGE -

LUXURY VINYL TILE SLEEPING ROOMS MANNINGTON CRISSCROSS ZOOM CHARCOAL -

LUXURY VINYL TILE OFFICES MANNINGTON ACCESS STONE LINEAR STONE SHALE -

RUBBER BASE PRIMARY BASE JOHNSONITE 283 TOAST -

TRANSITION STRIP LVT TO TILE SCHLUTER RENO-U AEU 35 SATIN ANODIZED -

TRANSITION STRIP LVT TO CONCRETE OR EPOXY SCHLUTER RENO-U AEU 100 SATIN ANODIZED -

CORNER GUARD OUTSIDE CORNERS INPRO TYPE 430 STAINLESS STEEL -

EPOXY RESINOUS FLOORING LOUNGE & SHARED SPACES DUR-A-FLEX DUR-A-QUARTZ Q28-23 -

GENERAL NOTES

• FINISHES INDICATED ARE THE APPROVED BASIS OF

DESIGN TO CONVEY COLOR, PATTERN, TEXTURE AND

SALIENT CHARACTERISTICS ONLY. THE LISTING OF

MANUFACTURER INFORMATION IS NOT INTENDED TO LIMIT

THE SELECTION OF PRODUCTS PROVIDED BY OTHER

MANUFACTURERS. PRODUCTS MEETING THESE CRITERIA

WILL BE CONSIDERED AND MUST BE REVIEWED BY THE

PROJECT MANAHGER AND APPROVED BY THE NAVFAC

CONTRACTING OFFICER.

FINISH ITEMS ARE NOT TO BE SUBSTITUTED DUE TO

ORDERING LEAD TIMES. IT IS THE CONTRACTOR ’S

RESPONSIBILITY TO ORDER ALL MATERIALS IN TIME TO

AVOID DELAYS.

• FINISH ITEMS ARE NOT TO BE SUBSTITUTED DUE TO

ORDERING LEAD TIMES. IT IS THE CONTRACTOR ’S

RESPONSIBILITY TO ORDER ALL MATERIALS IN TIME TO

AVOID DELAYS.

• ALL INTERIOR FINISHES IN VERTICAL EXIT WAYS, EXIT

LOBBIES, AND EXIT CORRIDORS MUST MEET MINIMUM

CLASS A RATING.

• SPRAY PAINT ELECTRICAL PANELS, ACCESS PANELS, AND

EXPANSION JOINTS TO MATCH THE ADJACENT WALL

COLOR. PANELS PAINTED BY BRUSH ARE NOT

ACCEPTABLE.

• ALL MATERIALS/PRODUCTS ARE TO BE INSTALLED PER

MANUFACTURER'S INSTALLATION REQUIREMENTS.

• ALL FLOORING TRANSITIONS MUST MEET ABA

GUIDELINES. FLOORING TRANSITIONS OCCURRING UNDER

DOORS MUST BE CENTERED UNDER DOOR.