Baker City - Architectural.pdf

PDF 20 MB Posted

Attached to
Baker City Armory Roof Replacement Project
Solicitation number
S-24800-00003705
Issued by
Baker County, Barlow City, Oregon

About this file

The provided document is an Architectural file related to the Baker City Armory Roof Replacement Project, a state and local contract opportunity in Baker City, Baker County, Oregon. The project requires a contractor to replace the existing membrane roofing and make repairs to the standing seam metal roofing on approximately 26,200 square feet of the Oregon Military's Baker City Armory.

The file does not contain pricing terms, set asides, incumbent information, funding requirements, or other salient financial details. It focuses solely on the technical scope of work for the roofing replacement project.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

¼

Detail 12/A-506, 5x5x3/8" angle, see general rules 1., 3., and 4

1. Angle length to be length of clear opening plus 4" min. bearing at both ends. Field verify.

Note the need to return veneer to wall as detailed in jamb details to provide adequate bearing where walls at openings are set back 2" from typical wall face.

3. Provide at least minimum required bearing area at masonry.

4. Angle is a floating lintel supported by brick veneer. No connection to wall required.

Detail 10/A-507, 7x4x3/8" angle, see general rules 1., 3., and 4.

Detail 1/A-507, 5x5x3/8" angle, see general rules 1., 3., and 4.

Detail 19/A-507, 4x4x3/8" angle, see general rules 1., and 4. front of angle to align with door frame.

1. Angle length to be length of clear opening plus 4" min. bearing at both ends.

Field verify. Note the need to return veneer to wall as detailed in jamb details to provide adequate bearing where walls at openings are set back 2" from typical wall face.

2. Provide minimum ¼" sealant joint at sheathing. Field Verify

3. Provide at least minimum required bearing area at masonry.

4. Angle is a floating lintel supported by brick veneer. No connection to wall required.

e threshold may be deleted at doors 103A, 101A and 101B. Provide a vinyl filler from the Pedimat to the quarry tile at the lobby side of the doors, under the doors.