B259 Asbestos Test Report.pdf
PDF 2 MB Posted
- Attached to
- B259 Epoxy Flooring
- Solicitation number
- FA446024Q0251
About this file
This document is a limited asbestos inspection report for Building 259 on the Little Rock Air Force Base in Jacksonville, Arkansas. The inspection was performed by Safety & Environmental Investigations, Inc. in August 2023 in preparation for future renovations to the flooring in the packing bay. The report states that no asbestos was detected in the samples collected from the floor tiles and cove base materials.
The related federal contract opportunity is for the removal and replacement of approximately 8,050 square feet of vinyl tile and 557 linear feet of base in Building 259. The contractor shall be responsible for all flooring preparation and installation of a new static-free epoxy floor finish in a light gray color, including a 4.5 inch cove base. The contract opportunity is solicitation FA446024Q0251 issued by the Department of the Air Force Air Mobility Command. Proposals are due by 1:00 PM CST on June 10, 2024. A site visit is scheduled for July 8, 2024.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
P.O. Box 22038, Little Rock, Arkansas 72221 Phone (501) 227-8900 FAX: (501) 227-7535
Safety & Environmental
Investigations, Inc.
LIMITED ASBESTOS INSPECTION REPORT
Building 259
Little Rock Air Force Base Jacksonville, Arkansas
August 2023
LIMITED ASBESTOS INSPECTION REPORT
Building 259
August 2023
Prepared For: Mike Minick
530 Thomas Avenue Little Rock AFB, Arkansas 72099
Prepared By: Safety & Environmental Investigations, Inc.
PO Box 22038 Little Rock, Arkansas 72221
Building 259 SEI Job # 23125 Page 3 Little Rock Air Force Base Jacksonville, Arkansas
Limited Asbestos Inspection Report Building 259
Jacksonville, Arkansas 72078
Safety & Environmental Investigations, (SEI) Inc. was retained by the Little Rock Air Force Base in Jacksonville, Arkansas to perform a limited pre-renovation asbestos inspection of the flooring in the packing bay of Building 259 located on the Little Rock Air Force Base, Jacksonville, Arkansas. On August 24th, 2023, Mr. Joshua Roberson (Certification #015183) of SEI, Inc. (License #000260) performed the on-site inspection and sampling of the structure for the presence of suspect asbestos-containing materials.
The inspection was performed following EPA AHERA guidelines (40 CFR 763) and NESHAP (40 CFR 61, Subpart M) and the Arkansas Department of Entergy and Environment, DEQ, Regulation 21.
Background
The structure is a single-story metal framed structure with a pitched, metal roof set on a concrete slab foundation. The interior finishes of the structure included fiberglass batt insulation, sheet rock walls and various floor coverings throughout the Packing Bay of the Structure. The structure was occupied and in good condition at the time of the inspection. The date of construction was unknown and according to the client, the structure is scheduled for future renovations to the flooring throughout the Packing Bay only.
Purpose of Study
The purpose of this study was to identify and collect samples of suspect asbestos-containing materials from the structure for laboratory analysis. At the client’s request, an inspection for the presence of suspect asbestos-containing materials was performed of the flooring in the packing bay of the structure.
Sampling was performed in accordance with guidelines published in the Asbestos Hazard Emergency Response Act (AHERA), 40 CFR Part 763. Suspect asbestos-containing materials were divided into three different categories: surfacing, thermal system insulation, and miscellaneous materials. Each category of materials was divided into homogeneous areas, which are defined as materials similar in appearance, color, texture, and installation date. Samples were collected from each homogeneous area according to the following scale:
Surfacing Materials: <1000 sq. ft. 3 Samples
1,000 – 5,000 sq. ft. 5 Samples >5,000 sq. ft. 7 Samples Thermal System Insulation any amount 3 Samples Minimum Miscellaneous Materials any amount 2 Samples Minimum
Building 259 SEI Job # 23125 Page 4
The Environmental Protection Agency defines an asbestos-containing material as any material which contains greater than one percent (1%) asbestos by weight. The entire homogeneous area is classified as asbestos-containing if any one (1) of the samples collected from that area is found to contain more than 1% asbestos. All samples collected from a homogeneous material must reveal a result of one (1) percent asbestos or less for a material to be considered non-asbestos containing.
The condition of suspect homogeneous areas was assessed to determine if the materials were friable (RACM) or non-friable. Friable materials (RACM) are materials that when dry can be crumbled, pulverized, or reduced to powder by hand pressure. Non-Friable materials are materials that cannot be crumbled, pulverized, or reduced to powder by hand pressure when dry. Non-Friable materials are divided into two categories, Category I Non-Friable materials, (asbestos-containing packing, gaskets, resilient floor coverings, and asphalt roofing products that contain >1% asbestos), and Category II Non-Friable materials (any material, excluding category I non-friable ACM, containing >1% asbestos that cannot be crumbled, pulverized, or reduced to powder by hand pressure).
Asbestos samples were analyzed via Polarized Light Microscopy utilizing EPA Method 600/R-93/116 by Crisp Analytical, LLC in Carrollton, Texas. CA Labs is accredited by the National Institute for Standards and Testing, National Voluntary Laboratory Accreditation Program for Bulk Asbestos Analysis (NVLAP Air and Bulk #200349-0). It should be noted EPA NESHAPS recommends point-counting of positive asbestos results revealing less than 10% asbestos content by visual estimation.
Findings
The following table provides a summary of the suspect asbestos-containing materials sampled from the structure, along with the analytical results and locations of the materials.
Building 259 SEI Job # 23125 Page 5 Little Rock Air Force Base Jacksonville, Arkansas
Table I – Asbestos Sample Summary Building 259
Little Rock Air Force Base Jacksonville, Arkansas
HA#
Sample
No.
Description
Analysis Result %/Type ACM
Sample Location
CB01
Brown Cove Base and Mastic Around Exterior of Offices
None Detected North End
Brown Cove Base and Mastic
Around Exterior of Offices None Detected South End
FT01
12x12 Red Floor Tile and Mastic
Throughout Packing Bay None Detected North End
12x12 Red Floor Tile and Mastic
Throughout Packing Bay None Detected Center
12x12 Red Floor Tile and Mastic
Throughout Packing Bay None Detected South End
FT02
12x12 Black Replacement Tiles and Mastic on South End
None Detected South End
12x12 Black Replacement Tiles and Mastic on South End None Detected South End
FT03
12x12 Tan/White Replacement Tiles and Mastic on South End
None Detected South End
12x12 Tan/White Replacement Tiles and Mastic on South End
None Detected South End
Safety & Environmental Investigations, Inc. has received the analytical results from the samples collected from Building 259 Located on the Little Rock Air Force Base, Jacksonville, Arkansas. The analysis revealed No Asbestos Detected in the samples collected.
Discussion
No other materials in the structure were included in this limited investigation.
Sample locations and the location of identified asbestos materials are noted on drawings included in the appendices of this report.
Limitations
This report relates to the flooring in the Packing Bay in Building 259 located on the Little Rock Air Force Base, Jacksonville, Arkansas. According to the client, this structure is scheduled for future renovations to the flooring in the Packing Bay.
Building 259 SEI Job # 23125 Page 6 Little Rock Air Force Base Jacksonville, Arkansas
Asbestos samples were collected from materials identified as Homogeneous Materials based upon visual inspection of the site. SEI, Inc. is not responsible for assumptions on homogeneity which prove to be incorrect. In addition, samples collected represent only that portion of the entire homogeneous material. SEI, Inc. is not responsible for materials not identified and sampled due to the restraints on accessibility of the material. No warranties, expressed or implied, relate to the previous and/or future conditions.
During any operations involving renovation or demolition, suspect asbestos materials may be encountered which were not identified in this inspection. Work should immediately cease, and a certified inspector contacted for further sampling to identify those additional materials.
Asbestos Analysis was performed by Crisp Analytical, LLC in Carrollton, Texas. CA Labs is solely responsible for all asbestos analytical results contained in and referred to in this report.
This report prepared by:
Joshua A. Roberson Field Services Manager Safety & Environmental Investigations, Inc.
APPENDICIES
FIELD LOGS
LABORATORY ANALYSIS RESULTS
Attn:
Customer Project:
Reference #: Date: 08/30/23
Analysis and Method
Discussion
Qualifications
CA Labs
Dedicated to QualityDedicated to QualityDedicated to QualityDedicated to Quality
Crisp Analytical, L.L.C.
1929 Old Denton Road
Carrollton, TX 75006
Phone 972-242-2754
Fax 972-242-2798
CA Labs, L.L.C.
12232 Industriplex, Suite 32
Baton Rouge, LA 70809
Phone 225-751-5632
Fax 225-751-5634
Materials Characterization - Bulk Asbestos Analysis Laboratory Analysis Report - Polarized Light
Safety & Environmental Investigations, Inc Robert Roberson
PO Box 22038
Little Rock, AR 72201 23125, LRAFB Bldg 259
CAL23087123AS
Summary of polarized light microscopy (PLM / Stereomicroscopy bulk asbestos analysis) using the methods described in 40CFR Part 763
Appendix E to Subpart E (Interim and EPA 600 / R-93 / 116 (Improved). The sample is first viewed with the aid of a stereomicroscope. Numerous liquid slide preparations are created for analysis under the polarized microscope where identifications and quantifications are preformed. Calibrated liquid refractive oils are used as liquid mouting medium. These oils are used for identification (dispersion staining). A calibrated visual estimation is reported, should any asbestiform mineral be present. Other techniques such as acid washing are used in conjugation with refractive oils for detection of smaller quantities of asbestos. All asbestos percentages are based on calibrated visual estimation traceable to NIST standards for regulated asbestos. Traceability to measurement and calibration is achieved by using known amounts and types of asbestos from standards where analyst and laboratory accuracy are measured. As little as 0.001% asbestos can be detected in favorable samples, while detection in unfavorable samples may approach the detection limit of 0.50% (well above the laboratory definition of trace).
Vermiculite containing samples may contain trace amounts of actinolite/tremolite. When not detected by PLM, these samples should be analyzed using TEM methods and / or water separation techniques. Suspected actinolite/vermiculite presence will be indicated through the sample comment section of this report.
Fibrous talc containing samples may contain a regulated asbestos fiber known as anthophyllite. Under certain conditions the same fiber may actually contain both talc and anthophyllite (a phenomenon called intergrowth). Again, TEM detection methods are recommended. CA Labs PLM report comments will denote suspected amounts of asbestiform anthophyllite with talc, where further analysis is recommended.
Some samples (floor tiles, surfacings, etc.) may contain fibers too small to be detectable by PLM analysis and should be analyzed by TEM bulk protocols.
A "trace asbestos" will be reported if the analyst observes far less than 1% asbestos. CA Labs defines "trace asbestos" as a few fibers detected by the analyst in several preparations and will indicate as such under these circumstances.
Since allowable variation in quantification of samples close to 1% is high, <1% may be reported. Such results are ideal for point counting, and the technique is mandatory for friable samples (NESHAP, Nov. 1990 and clarification letter 8 May 1991) under 1% percent asbestos or "trace asbestos".
In order to make all initial PLM reports issued from CA Labs NESHAP compliant, all <1% asbestos results (except floor tiles) will be point counted at no additional charge.
CA Labs is accredited by the National Voluntary Accreditation Program (NVLAP) for selected test methods for airborne fiber analysis (TEM), and for bulk asbestos fiber analysis (PLM). CA Labs is also accredited by AIHA LAP, LLC. in the PLM asbestos field of testing for Industrial Hygiene. All analysts have completed college courses or hold a degree in a natural science (geology, biology, or environmental science). Recognition by a state professional board in one these disciplines is preferred, but not required. Extensive in-house training programs are used to augment the educational background of the analyst. The Laboratory Director and Quality Manager have received supplemental McCrone Research training for asbestos identification. Analysis performed at Crisp Analytical Labs, LLC 1929 Old Denton Road Carrollton, TX 75006
Dallas NVLAP Lab Code 200349-0 TEM/PLM TCEQ# T104704513-15-3 TDH 30-0235
AIHA LAP, LLC Laboratory #102929
Labs
A
C
/data/wordandspreadsheets/templates/asbestos/PLMReport.xls (Revision 4 2/25/2020) Page 1 of 6
Customer Project: 23125, LRAFB Bldg 259 CA Labs Project #: CAL23087123AS
No Asbestos Detected.
Glossary of abbreviations (non-asbestos fibers and non-fibrous minerals):
CA Labs
Dedicated to QualityDedicated to QualityDedicated to QualityDedicated to Quality
Crisp Analytical, L.L.C.
1929 Old Denton Road
Carrollton, TX 75006
Phone 972-242-2754
Fax 972-242-2798
CA Labs, L.L.C.
12232 Industriplex, Suite 32
Baton Rouge, LA 70809
Phone 225-751-5632
Fax 225-751-5634
Overview of Project Sample Material Containing Asbestos
Laboratory
Sample ID
Sample # Layer # Analysts Physical Description of
Subsample
Asbestos type / calibrated visual estimate percent
List of Affected
Building Material
Types
Dallas NVLAP Lab Code 200349-0 TEM/PLM TCEQ# T104704513-15-3 TDH 30-0235
AIHA LAP, LLC Laboratory #102929 ca - carbonate gypsum - gypsum bi - binder or - organic ma - matrix mi - mica ve - vermiculite ot - other pe - perlite qu - quartz fg - fiberglass mw - mineral wool wo - wollastinite ta - talc sy - synthetic ce - cellulose br - brucite ka - kaolin (clay) pa - palygorskite (clay)
This report relates to the items tested. This report is not to be used by the customer to claim product certification, approval or endorsement by NVLAP, NIST, AIHA LAP, LLC, or any other agency of the federal government. This report may not be reproduced except in full without written permission from CA Labs. These results are submitted pursuant to CA Labs' current terms and sale, condition of sale, including the company's standard warranty and limitations of liability provisions and no responsibility or liability is assumed for the manner in which the results are used or interpreted. Unless notified in writing to return the samples covered by this report, CA Labs will store the samples for a period of ninety (90) days before discarding. A shipping or handling fee may be assessed for the return of any samples.
Labs
A
/data/wordandspreadsheets/templates/asbestos/PLMReport.xls (Revision 4 2/25/2020) Page 2 of 6
Customer Info: Attn: Customer Project:
Date:
Phone #
Fax #
John Monaco Senior Analyst
Analyst Julio Robles
CA Labs
Dedicated to QualityDedicated to QualityDedicated to QualityDedicated to Quality
Crisp Analytical, L.L.C.
1929 Old Denton Road
Carrollton, TX 75006
Phone 972-242-2754
Fax 972-242-2798
CA Labs, L.L.C.
12232 Industriplex, Suite 32
Baton Rouge, LA 70809
Phone 225-751-5632
Fax 225-751-5634
Polarized Light Asbestiform Materials Characterization
Robert Roberson CA Labs Project #:
Safety & Environmental Investigations, Inc 23125, LRAFB Bldg 259
CAL23087123AS
PO Box 22038
Little Rock, AR 72201 Turnaround Time: 8/30/2023
3 Days Samples Rec'd: 8/25/23 10:30AM
501-227-8900 Date Of Sampling: 8/24/2023
Purchase Order #:
Laboratory
Sample ID
Sample # Com ment
Layer
Analysts Physical Description of
Subsample
Homo-geneo us
(Y/N)
Asbestos type / calibrated visual estimate percent
Non-asbestos fiber type / percent
Non-fibrous type / percent
80656 CB01-01
CB01-
01-1
Cove Base/Mastic/ brown baseboard y None Detected 100% gy,ma
80656
CB01-
01-2 tan mastic y None Detected 100% gy,bi
80657 CB01-02
CB01-
02-1
Cove Base/Mastic/ brown baseboard y None Detected 100% gy,ma
80657
CB01-
02-2 tan mastic y None Detected 100% gy,bi
80658 FT01-03
FT01-
03-1 Floor Tile/Mastic/ tan floor tile y None Detected 100% qu,ca
80658
FT01-
03-2 tan mastic y None Detected 100% gy,bi
80658
FT01-
03-3 red floor tile y None Detected 100% qu,ca
Dallas NVLAP Lab Code 200349-0 TEM/PLM TCEQ# T104704513-15-3 TDH 30-0235
AIHA LAP, LLC Laboratory #102929 Analysis Method: Interim (40CFR Part 763 Appendix E to Subpart E) / Improved (EPA-600 / R-93/116). All samples received in good condition unless noted.
Preparation Method: HCL acid washing for carbonate based samples, chemical reduction for organically bound components, oil immersion for identification of asbestos types by dispersion attaining / becke line method.
ca - carbonate gy - gypsum bi - binder or - organic ma - matrix mi - mica ve - vermiculite ot - other pe - perlite qu - quartz fg - fiberglass mw - mineral wool wo - wollastonite ta - talc sy - synthetic ce - cellulose br - brucite ka - kaolin (clay) pa - palygorskite (clay) Approved Signatories:
Technical Manager
Tanner Rasmussen
1. Fire Damage significant fiber damage - reported percentages reflect unaltered fibers
2. Fire Damage no significant fiber damages effecting fibrous percentages
3. Actinolite in association with Vermiculite
4. Layer not analyzed - attached to previous positive layer and contamination is suspected
5. Not enough sample to analyze
6. Anthophyllite in association with Fibrous Talc
7. Contamination suspected from other building materials
8. Favorable scenario for water separation on vermiculite for possible analysis by another method
9. < 1% Result point counted positive
10. TEM analysis suggested
Labs
A
/data/wordandspreadsheets/templates/asbestos/PLMReport.xls (Revision 4 2/25/2020) Page 3 of 6
Phone #
Fax #
John Monaco Senior Analyst
Analyst Julio Robles
CA Labs
Dedicated to QualityDedicated to QualityDedicated to QualityDedicated to Quality
Crisp Analytical, L.L.C.
1929 Old Denton Road
Carrollton, TX 75006
Phone 972-242-2754
Fax 972-242-2798
CA Labs, L.L.C.
12232 Industriplex, Suite 32
Baton Rouge, LA 70809
Phone 225-751-5632
Fax 225-751-5634
Polarized Light Asbestiform Materials Characterization
Robert Roberson CA Labs Project #:
Safety & Environmental Investigations, Inc 23125, LRAFB Bldg 259
CAL23087123AS
PO Box 22038
Little Rock, AR 72201 Turnaround Time: 8/30/2023
3 Days Samples Rec'd: 8/25/23 10:30AM
501-227-8900 Date Of Sampling: 8/24/2023
Purchase Order #:
Laboratory
Sample ID
Sample # Com ment
Layer
Analysts Physical Description of
Subsample
Homo-geneo us
(Y/N)
Asbestos type / calibrated visual estimate percent
Non-asbestos fiber type / percent
Non-fibrous type / percent
80658
FT01-
03-4 tan mastic y None Detected 100% gy,bi
80659 FT01-04
FT01-
04-1 Floor Tile/Mastic/ tan floor tile y None Detected 100% qu,ca
80659
FT01-
04-2 tan mastic y None Detected 100% gy,bi
80659
FT01-
04-3 red floor tile y None Detected 100% qu,ca
80659
FT01-
04-4 tan mastic y None Detected 100% gy,bi
80660 FT01-05
FT01-
05-1 Floor Tile/Mastic/ red floor tile y None Detected 100% qu,ca
80660
FT01-
05-2 tan mastic y None Detected 100% gy,bi
Dallas NVLAP Lab Code 200349-0 TEM/PLM TCEQ# T104704513-15-3 TDH 30-0235
AIHA LAP, LLC Laboratory #102929 Analysis Method: Interim (40CFR Part 763 Appendix E to Subpart E) / Improved (EPA-600 / R-93/116). All samples received in good condition unless noted.
Preparation Method: HCL acid washing for carbonate based samples, chemical reduction for organically bound components, oil immersion for identification of asbestos types by dispersion attaining / becke line method.
ca - carbonate gy - gypsum bi - binder or - organic ma - matrix mi - mica ve - vermiculite ot - other pe - perlite qu - quartz fg - fiberglass mw - mineral wool wo - wollastonite ta - talc sy - synthetic ce - cellulose br - brucite ka - kaolin (clay) pa - palygorskite (clay) Approved Signatories:
Technical Manager
Tanner Rasmussen
1. Fire Damage significant fiber damage - reported percentages reflect unaltered fibers
2. Fire Damage no significant fiber damages effecting fibrous percentages
3. Actinolite in association with Vermiculite
4. Layer not analyzed - attached to previous positive layer and contamination is suspected
5. Not enough sample to analyze
6. Anthophyllite in association with Fibrous Talc
7. Contamination suspected from other building materials
8. Favorable scenario for water separation on vermiculite for possible analysis by another method
9. < 1% Result point counted positive
10. TEM analysis suggested
Labs
A
/data/wordandspreadsheets/templates/asbestos/PLMReport.xls (Revision 4 2/25/2020) Page 4 of 6
Phone #
Fax #
John Monaco Senior Analyst
Analyst Julio Robles
CA Labs
Dedicated to QualityDedicated to QualityDedicated to QualityDedicated to Quality
Crisp Analytical, L.L.C.
1929 Old Denton Road
Carrollton, TX 75006
Phone 972-242-2754
Fax 972-242-2798
CA Labs, L.L.C.
12232 Industriplex, Suite 32
Baton Rouge, LA 70809
Phone 225-751-5632
Fax 225-751-5634
Polarized Light Asbestiform Materials Characterization
Robert Roberson CA Labs Project #:
Safety & Environmental Investigations, Inc 23125, LRAFB Bldg 259
CAL23087123AS
PO Box 22038
Little Rock, AR 72201 Turnaround Time: 8/30/2023
3 Days Samples Rec'd: 8/25/23 10:30AM
501-227-8900 Date Of Sampling: 8/24/2023
Purchase Order #:
Laboratory
Sample ID
Sample # Com ment
Layer
Analysts Physical Description of
Subsample
Homo-geneo us
(Y/N)
Asbestos type / calibrated visual estimate percent
Non-asbestos fiber type / percent
Non-fibrous type / percent
80661 FT02-06
FT02-
06-1
Floor Tile/Mastic/ black floor tile y None Detected 100% qu,ca
80661
FT02-
06-2 tan mastic y None Detected 100% gy,bi
80661
FT02-
06-3 tan floor tile y None Detected 100% qu,ca
80661
FT02-
06-4 tan mastic y None Detected 100% gy,bi
80662 FT02-07
FT02-
07-1
Floor Tile/Mastic/ black floor tile y None Detected 100% qu,ca
80662
FT02-
07-2 tan mastic y None Detected 100% gy,bi
80662
FT02-
07-3 tan floor tile y None Detected 100% qu,ca
Dallas NVLAP Lab Code 200349-0 TEM/PLM TCEQ# T104704513-15-3 TDH 30-0235
AIHA LAP, LLC Laboratory #102929 Analysis Method: Interim (40CFR Part 763 Appendix E to Subpart E) / Improved (EPA-600 / R-93/116). All samples received in good condition unless noted.
Preparation Method: HCL acid washing for carbonate based samples, chemical reduction for organically bound components, oil immersion for identification of asbestos types by dispersion attaining / becke line method.
ca - carbonate gy - gypsum bi - binder or - organic ma - matrix mi - mica ve - vermiculite ot - other pe - perlite qu - quartz fg - fiberglass mw - mineral wool wo - wollastonite ta - talc sy - synthetic ce - cellulose br - brucite ka - kaolin (clay) pa - palygorskite (clay) Approved Signatories:
Technical Manager
Tanner Rasmussen
1. Fire Damage significant fiber damage - reported percentages reflect unaltered fibers
2. Fire Damage no significant fiber damages effecting fibrous percentages
3. Actinolite in association with Vermiculite
4. Layer not analyzed - attached to previous positive layer and contamination is suspected
5. Not enough sample to analyze
6. Anthophyllite in association with Fibrous Talc
7. Contamination suspected from other building materials
8. Favorable scenario for water separation on vermiculite for possible analysis by another method
9. < 1% Result point counted positive
10. TEM analysis suggested
Labs
A
/data/wordandspreadsheets/templates/asbestos/PLMReport.xls (Revision 4 2/25/2020) Page 5 of 6
Phone #
Fax #
John Monaco Senior Analyst
Analyst Julio Robles
CA Labs
Dedicated to QualityDedicated to QualityDedicated to QualityDedicated to Quality
Crisp Analytical, L.L.C.
1929 Old Denton Road
Carrollton, TX 75006
Phone 972-242-2754
Fax 972-242-2798
CA Labs, L.L.C.
12232 Industriplex, Suite 32
Baton Rouge, LA 70809
Phone 225-751-5632
Fax 225-751-5634
Polarized Light Asbestiform Materials Characterization
Robert Roberson CA Labs Project #:
Safety & Environmental Investigations, Inc 23125, LRAFB Bldg 259
CAL23087123AS
PO Box 22038
Little Rock, AR 72201 Turnaround Time: 8/30/2023
3 Days Samples Rec'd: 8/25/23 10:30AM
501-227-8900 Date Of Sampling: 8/24/2023
Purchase Order #:
Laboratory
Sample ID
Sample # Com ment
Layer
Analysts Physical Description of
Subsample
Homo-geneo us
(Y/N)
Asbestos type / calibrated visual estimate percent
Non-asbestos fiber type / percent
Non-fibrous type / percent
80662
FT02-
07-4 tan mastic y None Detected 100% gy,bi
80663 FT03-08
FT03-
08-1 Floor Tile/Mastic/ tan floor tile y None Detected 100% qu,ca
80663
FT03-
08-2 tan mastic with debris n None Detected 100% gy,bi,ot
80664 FT03-09
FT03-
09-1 Floor Tile/Mastic/ tan floor tile y None Detected 100% qu,ca
80664
FT03-
09-2 tan mastic with debris n None Detected 100% gy,bi,ot
Dallas NVLAP Lab Code 200349-0 TEM/PLM TCEQ# T104704513-15-3 TDH 30-0235
AIHA LAP, LLC Laboratory #102929 Analysis Method: Interim (40CFR Part 763 Appendix E to Subpart E) / Improved (EPA-600 / R-93/116). All samples received in good condition unless noted.
Preparation Method: HCL acid washing for carbonate based samples, chemical reduction for organically bound components, oil immersion for identification of asbestos types by dispersion attaining / becke line method.
ca - carbonate gy - gypsum bi - binder or - organic ma - matrix mi - mica ve - vermiculite ot - other pe - perlite qu - quartz fg - fiberglass mw - mineral wool wo - wollastonite ta - talc sy - synthetic ce - cellulose br - brucite ka - kaolin (clay) pa - palygorskite (clay) Approved Signatories:
1. Fire Damage significant fiber damage - reported percentages reflect unaltered fibers
2. Fire Damage no significant fiber damages effecting fibrous percentages
3. Actinolite in association with Vermiculite
4. Layer not analyzed - attached to previous positive layer and contamination is suspected
5. Not enough sample to analyze
6. Anthophyllite in association with Fibrous Talc
7. Contamination suspected from other building materials
8. Favorable scenario for water separation on vermiculite for possible analysis by another method
9. < 1% Result point counted positive
10. TEM analysis suggested
Technical Manager
Tanner Rasmussen
Labs
A
/data/wordandspreadsheets/templates/asbestos/PLMReport.xls (Revision 4 2/25/2020) Page 6 of 6
PHOTOGRAPHS
CB01 – Brown Cove Base and Mastic (Non-ACM)
FT01 – 12x12 Red Floor Tile and Mastic (Non-ACM)
FT02 – 12x12 Black Floor Tile and Mastic (Non-ACM)
FT03 – 12x12 Tan/White Floor Tile and Mastic (Non-ACM)
DRAWINGS
S E
I, I nc
N o
S ca le
B ui ld in g
L it tl e R oc k
A ir
F or ce B as e
Ja ck so nv il le
, A rk an sa s
S am pl e
L oc at io ns
C B
-0
C B
-0
F T
-0
F T
-0
F T
-0
F T
-0
F
T
-0
F T
-0
F
T
-0
COMPANY & INSPECTOR CERTIFICATIONS
File details come from the government source that posted it. Updated .