B1040 Second Floor.pdf

PDF 230 KB Posted

Attached to
Sound Testing IDIQ
Solicitation number
FA930226Q0031_V2
Issued by

About this file

This is an architectural plan document for RF (radio frequency) shielding specifications on the second floor of a secure facility. The plan illustrates the layout and shielding requirements for a secure perimeter area containing hardware-in-loop cockpits, ante bays, staging areas, and associated support spaces including toilet facilities, elevators, and corridors.

The shielding specifications require copper lining to be installed above the ceiling of enclosures in ante bays and integrated into RF panels per manufacturer specifications. No RF panel shielding is required on the east wall of ante bays, which features an unshielded window. The secure perimeter extends 1 meter horizontally around the full perimeter of the designated areas, with shielded sliding doors referenced to detailed schedules. The document includes two complementary plan views—one for the floor-level secure perimeter (Plan A1 at 3/64" scale) and one for the roof-level secure perimeter (Plan H1 at 3/64" scale)—each indicating test point areas marked for wall/door testing and ceiling/floor testing with directional indicators. References to detailed drawings (A-514, A-515, A-516) provide additional specifications for shielding materials, copper lining installation, and door schedules. This appears to be a construction or renovation specification document for a government or military facility requiring electromagnetic shielding compliance.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

UP

ELEC

HARDWARE-IN-LOOP

COCKPITS

HARDWARE-IN-LOOP

COCKPITS

ELEC

AN

TE

B

AY

S

AN

TE

B

AY

S

FREIGHT ELEV

STAGING

TOILE

ELEV

OPEN

BELOW

NO RF PANEL

SHIELDING ON EAST

WALL OF ANTE BAYS.

WINDOW IN WALL

WITHOUT SHIELDING

1 METER HORIZONTAL

EXTENSION. FULL PERIMETER.

1 METER HORIZONTAL

EXTENSION. FULL PERIMETER.

A13 A-514

E13 A-514 H17

A-514

. 1 G9 A-514 A-514

COPPER LINING TO BE

PROVIDED ABOVE CEILING

OF ENCLOSURE IN ANTE

BAYS AND RETURN INTO

RF PANELS AS PER

MANUFACTUER. REFER

TO DETAILING

NO RF PANEL

SHIELDING ON EAST

WALL OF ANTE BAYS.

WINDOW IN WALL

WITHOUT SHIELDING

COPPER LINING TO BE

PROVIDED ABOVE CEILING

OF ENCLOSURE IN ANTE

BAYS AND RETURN INTO

RF PANELS AS PER

MANUFACTUER. REFER

TO DETAILING

STAIRS #

E5

A-514

STAIR #1

1 METER HORIZONTAL

EXTENSION. FULL

PERIMETER.

SHIELDED SLIDING DOOR.

REFER TO SCHEDULE.

SHIELDED SLIDING DOOR.

REFER TO SCHEDULE.

1 METER HORIZONTAL

EXTENSION. FULL

PERIMETER.

TOILET SIM

204 A5

A-515 A9

203 CORRIDOR A-514

A5 A-516

A9 A-516

NOTE: REFERENCE

DETAILS ON A-516 FOR

ANTE BAYS 214

RF SHIELDED 11 GA

COPPER LINING RF

SHIELDING

COPPER LINING RF

SHIELDING AT

FLOOR - INCLUSIVE

BELOW RAISED

ACCESS FLOORING - 1

METER MINIMUM.

RF SHIELDED 11 GA

AT FLOOR

COPPER LINING RF

SHIELDING AT ROOF -

1 METER MINIMUM

RF SHIELDED 11 GA

BELOW ROOF

SECURED AREA

PERIMETER

ICD/ICS 705 w/ RF

SHIELDING

SECURED AREA

PERIMETER

ICD/ICS 705 WALL TYPE A

1 METER HORIZONTAL

EXTENSION. FULL PERIMETER.

1 METER HORIZONTAL

EXTENSION. FULL PERIMETER

ROOF DEC. ABOVE

SECURE AREA TO

TERMINATE FOR

CONTINUOUS

ENCLOSURE AT

LEVEL 2

ROOF DEC. ABOVE

SECURE AREA TO

TERMINATE FOR

CONTINUOUS

ENCLOSURE AT

LEVEL 2

D17 A-514

A17 A-514 L17

A-514

A17 A-514

SIM.

L9 A-514

COPPER LINING TO BE

PROVIDED ABOVE CEILING

OF ENCLOSURE IN ANTE

BAYS AND RETURN INTO

RF PANELS AS PER

MANUFACTUER. REFER

TO DETAILING

COPPER LINING TO BE

PROVIDED ABOVE CEILING

OF ENCLOSURE IN ANTE

BAYS AND RETURN INTO

RF PANELS AS PER

MANUFACTUER. REFER

TO DETAILING

E5 A-514

E9 A-514

E9 A-516

A5 A-516

A9 A-516

C

A B

D

US Army &orSs of Engineers ®

SHEET ID

N

3 5 7 9 11 13 15 17

L

G

E

C

A

DA

TE

DE

SC

RI

PT

IO

N

M

AR

K

2 4 6 10 12 14 16 1 19

SHIELDING LEGEND

P

M

K

H

F

D

B

KEY PLAN

AS-BUILT A120S

2N D

FL

O

O R

SE

C

U R

E

PE

R

IM

ET

ER

/S H

IE

LD

IN

G

PL

AN

S

C O

N

TR

AC

T

NO

W

2P L2

0C

SO

LI

C

IT

AT

IO

N

NO

W

2P

L2 0R

IS

SU

E

DA

TE

SE

PT

EM

BE

R

, 2

SU

BM

IT

TE

D

BY

PPC

H

EC

KE

D

BY

W F

D R

AW

N

BY

ALD

ES

IG

N

ED

BY

ES SI

ZE

AN

SI

D

TH

E

KO

R

TE

C

O M

PA

NY

U

S H

IG

H

W

AY

H

IG

H

LA

N

D ,I

L

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

RS

LO

S

AN

G

EL

ES

DI

ST

RI

CT

W

IL

SH

IR

E

BL

VD

,S

U

IT

E

0, LO

S

AN

G

EL

ES

C

AL

IF

O

R N

IA

R

EC

O R

D D

R

AW

IN

G

S

AS

-B U

IL

T

-2

ED

W

AR

D

S

AI

R

FO

R C

E

BA

SE

CA

LI

FO

RN

IA

-O

IN

T

SI

M U

LA

TI

O N

EN

VI

R O

N M

EN

T

FA

CI

LI

TY

3/64" = 1'-0"A1 2ND FLOOR SECURE PERIMETER / SHIELDING PLAN

PLAN NORTH

3/64" = 1'-0"H1 2ND FLOOR ROOF SECURE PERIMETER / SHIELDING PLAN

AS-B8ILT RECORD DRAWING

THIS RECORD DRAWINGS HAS BEEN

PREPARED, IN PART, BASED UPON

INFORMATION FURNISHED BY OTHERS.

WHILE THIS INFORMATION IS BELIEVED TO BE

RELIABLE, THE ARCHITECT/ENGINEER

ASSUMES NO RESPONSIBILITY FOR THE

ACCURACY OFTHIS RECORD DRAWING OR

RECORD SPECIFICATIONS OR FOR ANY

ERRORS OR OMISSIONS THAT MAY HAVE

BEEN INCORPORATED INTO IT AS A RESULT OF

INCORRECT INFORMATION PROVIDED TO THE

ARCHITECT/ENGINEER. THOSE RELYING ON

THIS RECORD DOCUMENT ARE ADVISED TO

OBTAIN INDEPENDENT VERIFICATION OF ITS

ACCURACY.

Indicates wall / door test point area

Indicates ceiling /floor test point area

Indicates direction of test points

File details come from the government source that posted it. Updated .