B1040 Second Floor.pdf
PDF 230 KB Posted
- Attached to
- Sound Testing IDIQ
- Solicitation number
- FA930226Q0031_V2
About this file
This is an architectural plan document for RF (radio frequency) shielding specifications on the second floor of a secure facility. The plan illustrates the layout and shielding requirements for a secure perimeter area containing hardware-in-loop cockpits, ante bays, staging areas, and associated support spaces including toilet facilities, elevators, and corridors.
The shielding specifications require copper lining to be installed above the ceiling of enclosures in ante bays and integrated into RF panels per manufacturer specifications. No RF panel shielding is required on the east wall of ante bays, which features an unshielded window. The secure perimeter extends 1 meter horizontally around the full perimeter of the designated areas, with shielded sliding doors referenced to detailed schedules. The document includes two complementary plan views—one for the floor-level secure perimeter (Plan A1 at 3/64" scale) and one for the roof-level secure perimeter (Plan H1 at 3/64" scale)—each indicating test point areas marked for wall/door testing and ceiling/floor testing with directional indicators. References to detailed drawings (A-514, A-515, A-516) provide additional specifications for shielding materials, copper lining installation, and door schedules. This appears to be a construction or renovation specification document for a government or military facility requiring electromagnetic shielding compliance.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
UP
ELEC
HARDWARE-IN-LOOP
COCKPITS
HARDWARE-IN-LOOP
COCKPITS
ELEC
AN
TE
B
AY
S
AN
TE
B
AY
S
FREIGHT ELEV
STAGING
TOILE
ELEV
OPEN
BELOW
NO RF PANEL
SHIELDING ON EAST
WALL OF ANTE BAYS.
WINDOW IN WALL
WITHOUT SHIELDING
1 METER HORIZONTAL
EXTENSION. FULL PERIMETER.
1 METER HORIZONTAL
EXTENSION. FULL PERIMETER.
A13 A-514
E13 A-514 H17
A-514
. 1 G9 A-514 A-514
COPPER LINING TO BE
PROVIDED ABOVE CEILING
OF ENCLOSURE IN ANTE
BAYS AND RETURN INTO
RF PANELS AS PER
MANUFACTUER. REFER
TO DETAILING
NO RF PANEL
SHIELDING ON EAST
WALL OF ANTE BAYS.
WINDOW IN WALL
WITHOUT SHIELDING
COPPER LINING TO BE
PROVIDED ABOVE CEILING
OF ENCLOSURE IN ANTE
BAYS AND RETURN INTO
RF PANELS AS PER
MANUFACTUER. REFER
TO DETAILING
STAIRS #
E5
A-514
STAIR #1
1 METER HORIZONTAL
EXTENSION. FULL
PERIMETER.
SHIELDED SLIDING DOOR.
REFER TO SCHEDULE.
SHIELDED SLIDING DOOR.
REFER TO SCHEDULE.
1 METER HORIZONTAL
EXTENSION. FULL
PERIMETER.
TOILET SIM
204 A5
A-515 A9
203 CORRIDOR A-514
A5 A-516
A9 A-516
NOTE: REFERENCE
DETAILS ON A-516 FOR
ANTE BAYS 214
RF SHIELDED 11 GA
COPPER LINING RF
SHIELDING
COPPER LINING RF
SHIELDING AT
FLOOR - INCLUSIVE
BELOW RAISED
ACCESS FLOORING - 1
METER MINIMUM.
RF SHIELDED 11 GA
AT FLOOR
COPPER LINING RF
SHIELDING AT ROOF -
1 METER MINIMUM
RF SHIELDED 11 GA
BELOW ROOF
SECURED AREA
PERIMETER
ICD/ICS 705 w/ RF
SHIELDING
SECURED AREA
PERIMETER
ICD/ICS 705 WALL TYPE A
1 METER HORIZONTAL
EXTENSION. FULL PERIMETER.
1 METER HORIZONTAL
EXTENSION. FULL PERIMETER
ROOF DEC. ABOVE
SECURE AREA TO
TERMINATE FOR
CONTINUOUS
ENCLOSURE AT
LEVEL 2
ROOF DEC. ABOVE
SECURE AREA TO
TERMINATE FOR
CONTINUOUS
ENCLOSURE AT
LEVEL 2
D17 A-514
A17 A-514 L17
A-514
A17 A-514
SIM.
L9 A-514
COPPER LINING TO BE
PROVIDED ABOVE CEILING
OF ENCLOSURE IN ANTE
BAYS AND RETURN INTO
RF PANELS AS PER
MANUFACTUER. REFER
TO DETAILING
COPPER LINING TO BE
PROVIDED ABOVE CEILING
OF ENCLOSURE IN ANTE
BAYS AND RETURN INTO
RF PANELS AS PER
MANUFACTUER. REFER
TO DETAILING
E5 A-514
E9 A-514
E9 A-516
A5 A-516
A9 A-516
C
A B
D
US Army &orSs of Engineers ®
SHEET ID
N
3 5 7 9 11 13 15 17
L
G
E
C
A
DA
TE
DE
SC
RI
PT
IO
N
M
AR
K
2 4 6 10 12 14 16 1 19
SHIELDING LEGEND
P
M
K
H
F
D
B
KEY PLAN
AS-BUILT A120S
2N D
FL
O
O R
SE
C
U R
E
PE
R
IM
ET
ER
/S H
IE
LD
IN
G
PL
AN
S
C O
N
TR
AC
T
NO
W
2P L2
0C
SO
LI
C
IT
AT
IO
N
NO
W
2P
L2 0R
IS
SU
E
DA
TE
SE
PT
EM
BE
R
, 2
SU
BM
IT
TE
D
BY
PPC
H
EC
KE
D
BY
W F
D R
AW
N
BY
ALD
ES
IG
N
ED
BY
ES SI
ZE
AN
SI
D
TH
E
KO
R
TE
C
O M
PA
NY
U
S H
IG
H
W
AY
H
IG
H
LA
N
D ,I
L
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
RS
LO
S
AN
G
EL
ES
DI
ST
RI
CT
W
IL
SH
IR
E
BL
VD
,S
U
IT
E
0, LO
S
AN
G
EL
ES
C
AL
IF
O
R N
IA
R
EC
O R
D D
R
AW
IN
G
S
AS
-B U
IL
T
-2
ED
W
AR
D
S
AI
R
FO
R C
E
BA
SE
CA
LI
FO
RN
IA
-O
IN
T
SI
M U
LA
TI
O N
EN
VI
R O
N M
EN
T
FA
CI
LI
TY
3/64" = 1'-0"A1 2ND FLOOR SECURE PERIMETER / SHIELDING PLAN
PLAN NORTH
3/64" = 1'-0"H1 2ND FLOOR ROOF SECURE PERIMETER / SHIELDING PLAN
AS-B8ILT RECORD DRAWING
THIS RECORD DRAWINGS HAS BEEN
PREPARED, IN PART, BASED UPON
INFORMATION FURNISHED BY OTHERS.
WHILE THIS INFORMATION IS BELIEVED TO BE
RELIABLE, THE ARCHITECT/ENGINEER
ASSUMES NO RESPONSIBILITY FOR THE
ACCURACY OFTHIS RECORD DRAWING OR
RECORD SPECIFICATIONS OR FOR ANY
ERRORS OR OMISSIONS THAT MAY HAVE
BEEN INCORPORATED INTO IT AS A RESULT OF
INCORRECT INFORMATION PROVIDED TO THE
ARCHITECT/ENGINEER. THOSE RELYING ON
THIS RECORD DOCUMENT ARE ADVISED TO
OBTAIN INDEPENDENT VERIFICATION OF ITS
ACCURACY.
Indicates wall / door test point area
Indicates ceiling /floor test point area
Indicates direction of test points
File details come from the government source that posted it. Updated .