B1040 First Floor.pdf
PDF 316 KB Posted
- Attached to
- Sound Testing IDIQ
- Solicitation number
- FA930226Q0031_V2
About this file
This document is an architectural floor plan for the 1st Floor Secure Perimeter of a facility. The plan includes both a reflected ceiling plan (H1) and a floor plan (A1), drawn at a scale of 3/64" = 1'-0", depicting a secure operations facility with multiple functional areas and rooms.
The facility contains numerous operational spaces including master operations control rooms (blue force, white force, and red force control rooms), mission briefing areas, cockpit simulation stations (both standard and high-fidelity configurations), secure communication and storage areas, and administrative offices. Supporting infrastructure consists of mechanical rooms, electrical closures, UPS systems, loading docks, staging areas, and circulation corridors. The plan identifies specific test point locations marked with color-coded indicators (green squares for wall/door test points, red squares for ceiling/floor test points) and directional arrows indicating test point orientation. The secure perimeter is clearly demarcated with dashed red lines, and the document notes that roof deck and floor deck above the secure area must terminate for continuous enclosure at Level 1. The facility appears designed for military or defense-related simulation and command operations, with emphasis on secure communications, data storage, and coordinated multi-force operational control.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
U3
COFFEE
BAR/
ROOM
ADV.
AST.
MOD SIM
BREAK
ROOM/
TDY
SURGE
NON
SECURE
COMM
MAN
TRAP
108 109
MASTER OPS
FAC MAN
OPS CHIEF
CHIEF 131
144 146
FILE JSE DEV
CTR
BLUE
FORCE
CONTROL
ROOM
WHITE
FORCE
CONTROL
ROOM
E;TRA
COCKPITS
E;TRA
COCKPITS
MISSION MISSION
BRIEFING BRIEFING
LOADING
DOCK /
STAGING
MISSION
BRIEFING
SPACE /
CYBER
ROOM
TECH
WORKSPACE
SECURE
STORAGE
SECURE
COMM
LARGE
DATA
STORAGE
RED
FORCE
CONTROL
ROOM
WOMENS
DIRECTORS SECURE
CONFERENCE VTC
JSE OPS
CHIEF
117.1
CORRIDOR
113 114 115
EWB
LEAD CHIEF CHIEF 116
ELEVATOR 138AFREIGHT ELEV MR
SECURITY
ITORIUM
RM/ MENS
JAN
CO
RR
ID
OR
7EWG / CC
PM LEAD
JSE M ; ROOM CHIEF145
ADMIN
106WAITING
105 TECH
EWS CUBICLES
JSE CUBICLES
JSE PM LEAD JSE E;P
148 149 150
HIGH FIDELITY COCKPITS
HIGH FIDELITY COCKPITS
STORAGE (HIGH BAY)
CORRIDOR
ELEC
UPS
MECHANICAL
CIRCULATION
FILE ARCHITECDTIRECTOR
EWB CUBICLES
MOTHER SB12R6EAK
SECURITYSECURITY MISSION
121 155 PLANNING
SECURITY
103B CONFERENCE LEAD
TOILET
TOILET
MENS
STAIR
STAIRS
ELEV
ELEV MR
CORRIDOR MAN TRAP
127 153
VESTIBULE LOBBY TASK
102 STATIONWOMENS
MECHANICAL
YARD
EL
EV
VE
ST
4A
A-515
A5 SIM
A8
A-515
A12 A-515
A1 A-515
A16 A-515
133 EWS BUS EWS DIV
LOGISTICS
TEAM EBW FMEBW DIV HRL
EWS SITESUPPORT
SUP DIV DIV
CHIEF CHIEF
A5 178 A-515
RSOIMOM 177
SECURED AREA
PERIMETER
ICD/ICS 705 w/ RF
SHIELDING
SECURED AREA
PERIMETER
ICD/ICS 705 WALL TYPE A
LOBBY
MECHANICAL
YARD
FLOOR DECK AT SECOND
LEVEL ABOVE SECURE AREA
TO TERMINATE FOR
CONTINUOUS ENCLOSURE
AT LEVEL 1
ROOF DECK ABOVE SECURE
AREA TO TERMINATE FOR
CONTINUOUS ENCLOSURE
AT LEVEL 1
ROOF DECK ABOVE SECURE
AREA TO TERMINATE FOR
CONTINUOUS ENCLOSURE
AT LEVEL 1
F8 A-515
E1 A-514
E16 H16 SIM
A-515 A-515
F12 A-515
F5 A-515
H16 SIM
A-515
A5 A-516
A9 A-516
C
A B
D
US Army Corps of Engineers ®
SHEET ID
D R
AW
N
BY
SU
BM
IT
TE
D B
Y:
N
3 5 7 9 11 13 15 17
L
G
E
C
A
DA
TE
M
AR
K
DE
SC
RI
PT
IO
N
2 4 6 10 12 14 16 1 19
SHIELDING LEGEND
P
M
K
H
F
D
B
AS-BUILT A110S
1S T
FL
O
O R
SE
C
U R
E
PE
R
IM
ET
ER
PL
AN
S
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
RS
LO
S
AN
G
EL
ES
DI
ST
RI
CT
C
AL
IF
O
R N
IA
TH
E
KO
R
TE
CO
M
PA
NY
U S
H
IG
H W
AY
H
IG
H
LA
N D
,I L
D
ES
IG
N
ED
BY
ES
W
IL
SH
IR
E
BL
VD
,S
U
IT
E
0, LO
S
AN
G
EL
ES
AL PP SI
ZE
AN
SI
D
C H
EC
KE
D
BY
W
F
IS
SU
E
DA
TE
SE
PT
EM
BE
R
,2
SO
LI
C
IT
AT
IO
N
NO
W
2P L2
0R
C
O N
TR
AC
T
NO
W
2P
L2 0C
R
EC
O R
D D
R
AW
IN
G
S
AS
-B U
IL
T
-2
ED
W
AR
D
S
AI
R
FO
R C
E
BA
SE
CA
LI
FO
RN
IA
-O
IN
T
SI
M U
LA
TI
O N
EN
VI
R O
N M
EN
T
FA
CI
LI
TY
3/64" = 1'-0"A1 1ST FLOOR SECURE PERIMETER FLOOR PLAN
PLAN NORTH
3/64" = 1'-0"H1 1ST FLOOR SECURE PERIMETER REFLECTED CEILING PLAN
AS BUILT RECORD DRAWING
THIS RECORD DRAWINGS HAS BEEN
PREPARED, IN PART, BASED UPON
INFORMATION FURNISHED BY OTHERS.
WHILE THIS INFORMATION IS BELIEVED TO BE
RELIABLE, THE ARCHITECT/ENGINEER
ASSUMES NO RESPONSIBILITY FOR THE
ACCURACY OFTHIS RECORD DRAWING OR
RECORD SPECIFICATIONS OR FOR ANY
ERRORS OR OMISSIONS THAT MAY HAVE
BEEN INCORPORATED INTO IT AS A RESULT
OF INCORRECT INFORMATION PROVIDED TO
THE ARCHITECT/ENGINEER. THOSE RELYING
ON THIS RECORD DOCUMENT ARE ADVISED
TO OBTAIN INDEPENDENT VERIFICATION OF
ITS ACCURACY.
3 Walls and door
Indicates wall / door test point area
Indicates ceiling / floor test point area
Indicates direction of test points
File details come from the government source that posted it. Updated .