B08_Attachment_11-Title_24_Indoor_Lighting.pdf

PDF 175 KB Posted

Attached to
GOGA CONSTRUCT STINSON LG TOWER & CAFE Federal contract opportunity
Solicitation number
140P8526R0007
Issued by
Department of the Interior National Park Service

About this file

This is a California Energy Commission Certificate of Compliance for Indoor Lighting demonstrating adherence to Title 24 Building Energy Efficiency Standards for 2022. The project, NPS GOGA Stinson Beach, comprises 2,550 square feet of conditioned space across two habitable stories located in Climate Zone 3. The facility includes restaurant and general occupancy uses with a new lighting system installation covering the entire conditioned area.

The lighting design achieves full compliance with an allowed power allocation of 1,566.3 watts against a designed capacity of 1,448 watts, resulting in a compliant margin. The fixture schedule specifies seven distinct lighting types: 6" LED downlights (12 units, 216W), 6" wet-rated canless LED (4 units, 56W), 4' surface-mounted linear LED (12 units, 228W), 8' linear suspended LED (5 units, 330W), 4' surface-mounted linear LED alternate (4 units, 76W), 2x2 LED recessed fixtures (14 units, 434W), and 2' LED vanity (6 units, 108W). Indoor lighting controls include manual area controls with dimmer capability in the kitchen, garage, and break area; occupancy sensors in restrooms, storage, hallways, and stairwells; and multi-level controls in the kitchen. The project also requires submission of Certificate of Installation form NRCI-LTI-E and Certificate of Acceptance form NRCA-LTI-02-A for occupancy sensors and automatic time switch controls across all specified spaces. Documentation was prepared by Brian Flynn of AE Design on February 20, 2024, with Compliance ID 177993-0224-0007.

View the file

Other files for this federal contract opportunity

Other files attached to GOGA CONSTRUCT STINSON LG TOWER & CAFE, newest first.
File Type Posted
B08_Attachment_19-Archive_Drawings_Complete_0003.pdf PDF
B08_Attachment_18-RFI_Responses_Rev_1_0003.pdf PDF
Sol_140P8526R0007_Amd_0003.pdf PDF
B08_Attachment_18-RFI_Responses_0002.pdf PDF
B08_Attachment_14-Bid_Schedule_Revision_1_0002.xlsx XLSX spreadsheet
B08_Attachment_3-Drawings_Revision_1_0002.pdf PDF
Sol_140P8526R0007_Amd_0002.pdf PDF
B08_Attachment_17-Site_Visit_Attendance_Record_0001.pdf PDF
Sol_140P8526R0007_Amd_0001.pdf PDF
Sol_140P8526R0007.pdf PDF
B08_Attachment_15-LmtOnSubconRpt.xlsx XLSX spreadsheet
B08_Attachment_3-Drawings.pdf PDF
B08_Attachment_14-Bid_Schedule.xlsx XLSX spreadsheet
B08_Attachment_16-WD_CA20260007.pdf PDF
B08_Attachment_10-Structural_Calculations.pdf PDF
B08_Attachment_2-Division_2_Specifications.pdf PDF
B08_Attachment_7-Hazmat_Survey_Report.pdf PDF
B08_Attachment_9-Dune_Mitigation_and_Monitoring_Report.pdf PDF
B08_Attachment_8-Geotechnical_Investigation_Report.pdf PDF
B08_Attachment_5-HVAC_Load_Calculations.pdf PDF
B08_Attachment_6-Statement_of_Structural_Tests_Special_Inspections.pdf PDF
B08_Attachment_12-Title_24_Outdoor_Lighting.pdf PDF
B08_Attachment_4-Product_Files_Reduced.pdf PDF
B08_Attachment_1-Division_One_Specifications.pdf PDF
B08_Attachment_13-Construction_Contract_Administration.pdf PDF
Show all 25

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Generated Date/Time: Documentation Software: Energy Code Ace

CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220101

Compliance ID: 177993-0224-0007 Report Generated: 2024-02-20 12:28:54

STATE OF CALIFORNIA

Indoor Lighting CALIFORNIA ENERGY COMMISSION

CERTIFICATE OF COMPLIANCE NRCC-LTI-E

This document is used to demonstrate compliance with requirements in 110.9, 110.12(c), 130.0, 130.1, 140.6 and 141.0(b)2 for indoor lighting scopes using the prescriptive path for nonresidential and hotel/motel occupancies. It is also used to document compliance with requirements in 160.5, 170.2(e) and 180.2(b)4 for indoor lighting scopes using the prescriptive path for multifamily occupancies. Multifamily includes dormitory and senior living facilities.

Project Name: NPS GOGA Stinson Beach Report Page: (Page 1 of 8) Project Address: Date Prepared: 2024-02-20T15:28:51-05:00

A. GENERAL INFORMATION

01 Project Location (city) Stinson Beach 04 Total Conditioned Floor Area (ft2) 2,550 02 Climate Zone 3 05 Total Unconditioned Floor Area (ft2) 0 03 Occupancy Types Within Project (select all that apply): 06 # of Stories (Habitable Above Grade) 2

● Restaurant ● All Other Occupancies

B. PROJECT SCOPE

This table includes any lighting systems that are within the scope of the permit application and are demonstrating compliance using the prescriptive path outlined in 140.6 / 170.2(e) or 141.0(b)2 / 180.2(b)4 for alterations.

Scope of Work Conditioned Spaces Unconditioned Spaces 01 02 03 04 05

My Project Consists of (check all that apply): Calculation Method Area (ft2) Calculation Method Area (ft2) New Lighting System Area Category Method 2550 N/A 0 New Lighting System - Parking Garage N/A 0 N/A 0

Total Area of Work (ft2) 2550

STATE OF CALIFORNIA

Indoor Lighting CALIFORNIA ENERGY COMMISSION

CERTIFICATE OF COMPLIANCE NRCC-LTI-E

Project Name: NPS GOGA Stinson Beach Report Page: (Page 2 of 8)

Date Prepared: 2024-02-20T15:28:51-05:00

Generated Date/Time: Documentation Software: Energy Code Ace

CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220101

Compliance ID: 177993-0224-0007 Report Generated: 2024-02-20 12:28:54

C. COMPLIANCE RESULTS

If any cell on this table says "DOES NOT COMPLY" or "COMPLIES with Exceptional Conditions" refer to Table D. for guidance.

Lighting in conditioned and unconditioned spaces must not be combined for compliance per

140.6(b)1 / 170.2(e)

Allowed Lighting Power per 140.6(b) / 170.2(e) (Watts)

Adjusted Lighting Power per 140.6(a) / 170.2(e) (Watts) Compliance Results

01 02 03 04

05 06 07

08 09

Complete Building 140.6(c)1

Area Category 140.6(c)2 / 170.2(e)4

Area Category Additional 140.6(c)2G / 170.2(e)4Av

Tailored 140.6(c)3 / 170.2(e)4B

Total Allowed (Watts)

Total Designed (Watts)

Adjustments

Total Adjusted (Watts) *Includes

Adjustments

05 must be >= 08

140.6 / 170.2(e)

PAF Lighting Control Credits 140.6(a)2 / 170.2(e)1B

(See Table I) (See Table I) (See Table J) (See Table K) (See Table F) (See Table P)

Conditioned 1,566.3 = 1,566.3 ≥ 1,448 = 1448 COMPLIES Unconditioned = ≥ =

Controls Compliance (See Table H for Details) COMPLIES Rated Power Reduction Compliance (See Table Q for Details)

D. EXCEPTIONAL CONDITIONS

This table is auto-filled with uneditable comments because of selections made or data entered in tables throughout the form.

E. ADDITIONAL REMARKS

This table includes remarks made by the permit applicant to the Authority Having Jurisdiction.

CERTIFICATE OF COMPLIANCE NRCC-LTI-E

Project Name: NPS GOGA Stinson Beach Report Page: (Page 3 of 8)

Date Prepared: 2024-02-20T15:28:51-05:00

Generated Date/Time: Documentation Software: Energy Code Ace

CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220101

Compliance ID: 177993-0224-0007 Report Generated: 2024-02-20 12:28:54

F. INDOOR LIGHTING FIXTURE SCHEDULE

This table includes all planned permanent and portable lighting other than dwelling unit/ hotel/ motel room lighting. Multifamily dwelling unit and hotel/motel room lighting is documented in Table T. If using Table T to document lighting in multifamily common use areas providing shared provisions for living, eating, cooking or sanitation, those luminaires are not included here.

Designed Wattage: Conditioned Spaces

01 02 03 04 05 06 07 08 09 10

Name or Item Tag

Complete Luminaire Description

Modular (Track) Fixture

Small Aperture &

Color Change1 Watts per luminaire2

How is Wattage determined

Total Number of Luminaires

Excluded per 140.6(a)3 / 170.2(e)2C

Design Watts Field Inspector

Pass Fail

D1/D1EM 6" LED DOWNLIGHTS No NA 18 Mfr. Spec 12 No 216 D2 6" WET RATED CANLESS LED No NA 14 Mfr. Spec 4 No 56

L1/L1EM 4' SURFACE MOUNTED

LINEAR LED No NA 19 Mfr. Spec 12 No 228

L2/L2EM 8' LINEAR SUSPENDED LED No NA 66 Mfr. Spec 5 No 330

L3/L3EM 4' SURFACE MOUNTED

LINEAR LED No NA 19 Mfr. Spec 4 No 76

R2/R2EM 2X2 LED RECESSED No NA 31 Mfr. Spec 14 No 434 W1 2' LED VANITY No NA 18 Mfr. Spec 6 No 108

Total Designed Watts: CONDITIONED SPACES 1,448 1FOOTNOTE: Design Watts for small aperture and color changing luminaires which qualify per 140.6(a)4B / 170.2(e)2D is adjusted to be 75% /80% of their rated wattage. Table F automatically makes this adjustment, the permit applicant should enter full rated wattage in column 05.

2Authority Having Jurisdiction may ask for Luminaire cut sheets to confirm wattage used for compliance per 130.0(c) / 160.5(b). Wattage used must be the maximum rated for the luminaire, not the lamp.

G. MODULAR LIGHTING SYSTEMS

This section does not apply to this project.

CERTIFICATE OF COMPLIANCE NRCC-LTI-E

Project Name: NPS GOGA Stinson Beach Report Page: (Page 4 of 8)

Date Prepared: 2024-02-20T15:28:51-05:00

Generated Date/Time: Documentation Software: Energy Code Ace

CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220101

Compliance ID: 177993-0224-0007 Report Generated: 2024-02-20 12:28:54

H. INDOOR LIGHTING CONTROLS (Not including PAFs) This table includes lighting controls for conditioned and unconditioned spaces.

Building Level Controls

01 02 03

Mandatory Demand Response 110.12(c) Shut-off controls 130.1(c) / 160.5(b)4C Field Inspector Pass Fail

NA < 4,000W subject to multilevel See Area/Space Level Controls Area Level Controls

04 05 06 07 08 09 10 11 12

Area Description Complete Building or Area Category Primary Function

Area

Manual Area Controls 130.1(a) / 160.5(b)4A

Multi-Level Controls 130.1(b) / 160.5(b)4B

Shut-Off Controls 130.1(c) // 160.5(b)4C

Primary/Sky lit

Daylighting 130.1(d) / 160.5(b)4D

Secondary Daylighting 130.1(d) / 160.5(b)4D

Interlocked Systems 140.6(a)1/ 170.2(e)2A

Field Inspector

Pass Fail

KITCHEN Kitchen/ Food Preparation Readily Accessible Dimmer Occupancy Sensor NA: General

Ltg < 120W NA: General Ltg < 120W No

RESTROOM Restroom Readily Accessible NA: Restrooms Occupancy Sensor NA: Not daylit zone NA: Not daylit zone No

STORAGE Storage - MF common areas Readily Accessible

NA: Enclosed area <100SF Occupancy Sensor NA: Not daylit zone NA: Not daylit zone No

HALLWAY Corridor Readily Accessible

NA: General Ltg <= 0.5W/SF Occupancy Sensor NA: Not daylit zone NA: Not daylit zone No

GARAGE General Commercial Industrial Work Area High Bay

Readily Accessible Dimmer Occupancy Sensor NA: Not daylit zone NA: Not daylit zone No

STAIRWELL Stairwell Readily Accessible

NA: General Ltg <= 0.5W/SF Occupancy Sensor NA: Not daylit zone NA: Not daylit zone No

BREAK AREA Lounge Readily Accessible Dimmer Occupancy Sensor NA: General

Ltg < 120W NA: General Ltg < 120W No

WATCH TOWER All Other Space Types Readily Accessible

NA: Enclosed area <100SF Occupancy Sensor NA: General

Ltg < 120W NA: General Ltg < 120W No

CERTIFICATE OF COMPLIANCE NRCC-LTI-E

Project Name: NPS GOGA Stinson Beach Report Page: (Page 5 of 8)

Date Prepared: 2024-02-20T15:28:51-05:00

Generated Date/Time: Documentation Software: Energy Code Ace

CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220101

Compliance ID: 177993-0224-0007 Report Generated: 2024-02-20 12:28:54

H. INDOOR LIGHTING CONTROLS (Not including PAFs)

Plan Sheet Showing Daylit Zones:

I. LIGHTING POWER ALLOWANCE: COMPLETE BUILDING OR AREA CATEGORY METHODS

Each area complying using the Complete Building or Area Category Methods per 140.6(b) are included in this table. Column 06 indicates if additional lighting power allowances per 140.6(c) or adjustments per 140.6(a) are being used .

Conditioned Spaces

01 02 03 04 05 06

Area Description Complete Building or Area Category Primary Function Area

Allowed Density (W/ft2) Area (ft2) Allowed Wattage

(Watts) Additional Allowance / Adjustment Area Category PAF

KITCHEN Kitchen/ Food Preparation 0.95 574 545.3 No No RESTROOM Restroom 0.65 410 266.5 No No STORAGE Storage - MF common areas 0.45 82 36.9 No No HALLWAY Corridor 0.4 211 84.4 No No

GARAGE General Commercial Industrial Work Area High Bay 0.65 623 404.95 No No

STAIRWELL Stairwell 0.6 99 59.4 No No BREAK AREA Lounge 0.55 235 129.25 No No

WATCH TOWER All Other Space Types 0.4 99 39.6 No No TOTALS: 2,333 1,566.3 See Tables J, or P for detail

J. ADDITIONAL ALLOWANCE: AREA CATEGORY METHOD QUALIFYING LIGHTING SYSTEM

CERTIFICATE OF COMPLIANCE NRCC-LTI-E

Project Name: NPS GOGA Stinson Beach Report Page: (Page 6 of 8)

Date Prepared: 2024-02-20T15:28:51-05:00

Generated Date/Time: Documentation Software: Energy Code Ace

CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220101

Compliance ID: 177993-0224-0007 Report Generated: 2024-02-20 12:28:54

K. TAILORED METHOD GENERAL LIGHTING POWER ALLOWANCE

This section does not apply to this project.

L. ADDITIONAL LIGHTING ALLOWANCE: TAILORED WALL DISPLAY

This section does not apply to this project.

M. ADDITIONAL LIGHTING ALLOWANCE: TAILORED FLOOR AND TASK LIGHTING

This section does not apply to this project.

N. ADDITIONAL LIGHTING ALLOWANCE: TAILORED DECORATIVE /SPECIAL EFFECTS

This section does not apply to this project.

O. ADDITIONAL LIGHTING ALLOWANCE: TAILORED VERY VALUABLE MERCHANDISE

This section does not apply to this project.

P. POWER ADJUSTMENT: LIGHTING CONTROL CREDIT (POWER ADJUSTMENT FACTOR (PAF))

This section does not apply to this project.

Q. RATED POWER REDUCTION COMPLIANCE FOR ONE-FOR-ONE ALTERATIONS

This section does not apply to this project.

R. 80% LIGHTING POWER FOR ALL ALTERATIONS - CONTROLS EXCEPTIONS

CERTIFICATE OF COMPLIANCE NRCC-LTI-E

Project Name: NPS GOGA Stinson Beach Report Page: (Page 7 of 8)

Date Prepared: 2024-02-20T15:28:51-05:00

Generated Date/Time: Documentation Software: Energy Code Ace

CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220101

Compliance ID: 177993-0224-0007 Report Generated: 2024-02-20 12:28:54

S. DAYLIGHT DESIGN POWER ADJUSTMENT FACTOR (PAF)

This section does not apply to this project.

T. DWELLING UNIT LIGHTING

This section does not apply to this project.

U. DECLARATION OF REQUIRED CERTIFICATES OF INSTALLATION

Selections have been made based on information provided in this document. If any selections have been changed by permit applicant, an explanation should be included in Table E.

Additional Remarks. These documents must be provided to the building inspector during construction and can be found online

Form/Title

NRCI-LTI-E - Must be submitted for all buildings

V. DECLARATION OF REQUIRED CERTIFICATES OF ACCEPTANCE

Selections have been made based on information provided in this document. If any selections have been changed by the permit applicant, an explanation should be included in Table E.

Additional Remarks. These documents must be provided to the building inspector during construction and any with "-A" in the form name must be completed through an Acceptance Test Technician Certification Provider (ATTCP). For more information visit: http://www.energy.ca.gov/title24/attcp/providers.html

Form/Title Systems/Spaces To Be Field Verified

NRCA-LTI-02-A - Must be submitted for occupancy sensors and automatic time switch controls. KITCHEN; RESTROOM;

STORAGE; HALLWAY;

GARAGE; STAIRWELL; BREAK

AREA; WATCH TOWER

CERTIFICATE OF COMPLIANCE NRCC-LTI-E

Project Name: NPS GOGA Stinson Beach Report Page: (Page 8 of 8) Project Address: Date Prepared: 2024-02-20T15:28:51-05:00

Generated Date/Time: Documentation Software: Energy Code Ace

CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220101

Compliance ID: 177993-0224-0007 Report Generated: 2024-02-20 12:28:54

DOCUMENTATION AUTHOR'S DECLARATION STATEMENT

I certify that this Certificate of Compliance documentation is accurate and complete.

Documentation Author Name:

Brian Flynn

Documentation Author Signature:

Company:

AE Design

Signature Date:

Address: CEA/ HERS Certification Identification (if applicable):

City/State/Zip: Phone:

RESPONSIBLE PERSON'S DECLARATION STATEMENT

I certify the following under penalty of perjury, under the laws of the State of California:

1. The information provided on this Certificate of Compliance is true and correct.

2. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer)

3. The energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.

4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.

5. I will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a completed signed copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy.

Responsible Designer Name: Responsible Designer Signature:

Company: Date Signed:

Address: License:

City/State/Zip: Phone:

Section A - A. GENERAL INFORMATION
Section B - B. PROJECT SCOPE
Section C - C. COMPLIANCE RESULTS
Section D - D. EXCEPTIONAL CONDITIONS
Section E - E. ADDITIONAL REMARKS
Section F - F. INDOOR LIGHTING FIXTURE SCHEDULE
Section G - G. MODULAR LIGHTING SYSTEMS
Section H - H. INDOOR LIGHTING CONTROLS (Not including PAFs)
Section I - I. LIGHTING POWER ALLOWANCE: COMPLETE BUILDING OR AREA CATEGORY METHODS
Section J - J. ADDITIONAL ALLOWANCE: AREA CATEGORY METHOD QUALIFYING LIGHTING SYSTEM
Section K - K. TAILORED METHOD GENERAL LIGHTING POWER ALLOWANCE
Section L - L. ADDITIONAL LIGHTING ALLOWANCE: TAILORED WALL DISPLAY
Section M - M. ADDITIONAL LIGHTING ALLOWANCE: TAILORED FLOOR AND TASK LIGHTING
Section N - N. ADDITIONAL LIGHTING ALLOWANCE: TAILORED DECORATIVE /SPECIAL EFFECTS
Section O - O. ADDITIONAL LIGHTING ALLOWANCE: TAILORED VERY VALUABLE MERCHANDISE
Section P - P. POWER ADJUSTMENT: LIGHTING CONTROL CREDIT (POWER ADJUSTMENT FACTOR (PAF))
Section Q - Q. RATED POWER REDUCTION COMPLIANCE FOR ONE-FOR-ONE ALTERATIONS
Section R - R. 80% LIGHTING POWER FOR ALL ALTERATIONS - CONTROLS EXCEPTIONS
Section S - S. DAYLIGHT DESIGN POWER ADJUSTMENT FACTOR (PAF)
Section T - T. DWELLING UNIT LIGHTING
Documentation Author's Declaration Statement