B08_Attachment_11-Title_24_Indoor_Lighting.pdf
PDF 175 KB Posted
- Attached to
- GOGA CONSTRUCT STINSON LG TOWER & CAFE Federal contract opportunity
- Solicitation number
- 140P8526R0007
About this file
This is a California Energy Commission Certificate of Compliance for Indoor Lighting demonstrating adherence to Title 24 Building Energy Efficiency Standards for 2022. The project, NPS GOGA Stinson Beach, comprises 2,550 square feet of conditioned space across two habitable stories located in Climate Zone 3. The facility includes restaurant and general occupancy uses with a new lighting system installation covering the entire conditioned area.
The lighting design achieves full compliance with an allowed power allocation of 1,566.3 watts against a designed capacity of 1,448 watts, resulting in a compliant margin. The fixture schedule specifies seven distinct lighting types: 6" LED downlights (12 units, 216W), 6" wet-rated canless LED (4 units, 56W), 4' surface-mounted linear LED (12 units, 228W), 8' linear suspended LED (5 units, 330W), 4' surface-mounted linear LED alternate (4 units, 76W), 2x2 LED recessed fixtures (14 units, 434W), and 2' LED vanity (6 units, 108W). Indoor lighting controls include manual area controls with dimmer capability in the kitchen, garage, and break area; occupancy sensors in restrooms, storage, hallways, and stairwells; and multi-level controls in the kitchen. The project also requires submission of Certificate of Installation form NRCI-LTI-E and Certificate of Acceptance form NRCA-LTI-02-A for occupancy sensors and automatic time switch controls across all specified spaces. Documentation was prepared by Brian Flynn of AE Design on February 20, 2024, with Compliance ID 177993-0224-0007.
View the file
Other files for this federal contract opportunity
Show all 25
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Generated Date/Time: Documentation Software: Energy Code Ace
CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220101
Compliance ID: 177993-0224-0007 Report Generated: 2024-02-20 12:28:54
STATE OF CALIFORNIA
Indoor Lighting CALIFORNIA ENERGY COMMISSION
CERTIFICATE OF COMPLIANCE NRCC-LTI-E
This document is used to demonstrate compliance with requirements in 110.9, 110.12(c), 130.0, 130.1, 140.6 and 141.0(b)2 for indoor lighting scopes using the prescriptive path for nonresidential and hotel/motel occupancies. It is also used to document compliance with requirements in 160.5, 170.2(e) and 180.2(b)4 for indoor lighting scopes using the prescriptive path for multifamily occupancies. Multifamily includes dormitory and senior living facilities.
Project Name: NPS GOGA Stinson Beach Report Page: (Page 1 of 8) Project Address: Date Prepared: 2024-02-20T15:28:51-05:00
A. GENERAL INFORMATION
01 Project Location (city) Stinson Beach 04 Total Conditioned Floor Area (ft2) 2,550 02 Climate Zone 3 05 Total Unconditioned Floor Area (ft2) 0 03 Occupancy Types Within Project (select all that apply): 06 # of Stories (Habitable Above Grade) 2
● Restaurant ● All Other Occupancies
B. PROJECT SCOPE
This table includes any lighting systems that are within the scope of the permit application and are demonstrating compliance using the prescriptive path outlined in 140.6 / 170.2(e) or 141.0(b)2 / 180.2(b)4 for alterations.
Scope of Work Conditioned Spaces Unconditioned Spaces 01 02 03 04 05
My Project Consists of (check all that apply): Calculation Method Area (ft2) Calculation Method Area (ft2) New Lighting System Area Category Method 2550 N/A 0 New Lighting System - Parking Garage N/A 0 N/A 0
Total Area of Work (ft2) 2550
STATE OF CALIFORNIA
Indoor Lighting CALIFORNIA ENERGY COMMISSION
CERTIFICATE OF COMPLIANCE NRCC-LTI-E
Project Name: NPS GOGA Stinson Beach Report Page: (Page 2 of 8)
Date Prepared: 2024-02-20T15:28:51-05:00
Generated Date/Time: Documentation Software: Energy Code Ace
CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220101
Compliance ID: 177993-0224-0007 Report Generated: 2024-02-20 12:28:54
C. COMPLIANCE RESULTS
If any cell on this table says "DOES NOT COMPLY" or "COMPLIES with Exceptional Conditions" refer to Table D. for guidance.
Lighting in conditioned and unconditioned spaces must not be combined for compliance per
140.6(b)1 / 170.2(e)
Allowed Lighting Power per 140.6(b) / 170.2(e) (Watts)
Adjusted Lighting Power per 140.6(a) / 170.2(e) (Watts) Compliance Results
01 02 03 04
05 06 07
08 09
Complete Building 140.6(c)1
Area Category 140.6(c)2 / 170.2(e)4
Area Category Additional 140.6(c)2G / 170.2(e)4Av
Tailored 140.6(c)3 / 170.2(e)4B
Total Allowed (Watts)
Total Designed (Watts)
Adjustments
Total Adjusted (Watts) *Includes
Adjustments
05 must be >= 08
140.6 / 170.2(e)
PAF Lighting Control Credits 140.6(a)2 / 170.2(e)1B
(See Table I) (See Table I) (See Table J) (See Table K) (See Table F) (See Table P)
Conditioned 1,566.3 = 1,566.3 ≥ 1,448 = 1448 COMPLIES Unconditioned = ≥ =
Controls Compliance (See Table H for Details) COMPLIES Rated Power Reduction Compliance (See Table Q for Details)
D. EXCEPTIONAL CONDITIONS
This table is auto-filled with uneditable comments because of selections made or data entered in tables throughout the form.
E. ADDITIONAL REMARKS
This table includes remarks made by the permit applicant to the Authority Having Jurisdiction.
CERTIFICATE OF COMPLIANCE NRCC-LTI-E
Project Name: NPS GOGA Stinson Beach Report Page: (Page 3 of 8)
Date Prepared: 2024-02-20T15:28:51-05:00
Generated Date/Time: Documentation Software: Energy Code Ace
CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220101
Compliance ID: 177993-0224-0007 Report Generated: 2024-02-20 12:28:54
F. INDOOR LIGHTING FIXTURE SCHEDULE
This table includes all planned permanent and portable lighting other than dwelling unit/ hotel/ motel room lighting. Multifamily dwelling unit and hotel/motel room lighting is documented in Table T. If using Table T to document lighting in multifamily common use areas providing shared provisions for living, eating, cooking or sanitation, those luminaires are not included here.
Designed Wattage: Conditioned Spaces
01 02 03 04 05 06 07 08 09 10
Name or Item Tag
Complete Luminaire Description
Modular (Track) Fixture
Small Aperture &
Color Change1 Watts per luminaire2
How is Wattage determined
Total Number of Luminaires
Excluded per 140.6(a)3 / 170.2(e)2C
Design Watts Field Inspector
Pass Fail
D1/D1EM 6" LED DOWNLIGHTS No NA 18 Mfr. Spec 12 No 216 D2 6" WET RATED CANLESS LED No NA 14 Mfr. Spec 4 No 56
L1/L1EM 4' SURFACE MOUNTED
LINEAR LED No NA 19 Mfr. Spec 12 No 228
L2/L2EM 8' LINEAR SUSPENDED LED No NA 66 Mfr. Spec 5 No 330
L3/L3EM 4' SURFACE MOUNTED
LINEAR LED No NA 19 Mfr. Spec 4 No 76
R2/R2EM 2X2 LED RECESSED No NA 31 Mfr. Spec 14 No 434 W1 2' LED VANITY No NA 18 Mfr. Spec 6 No 108
Total Designed Watts: CONDITIONED SPACES 1,448 1FOOTNOTE: Design Watts for small aperture and color changing luminaires which qualify per 140.6(a)4B / 170.2(e)2D is adjusted to be 75% /80% of their rated wattage. Table F automatically makes this adjustment, the permit applicant should enter full rated wattage in column 05.
2Authority Having Jurisdiction may ask for Luminaire cut sheets to confirm wattage used for compliance per 130.0(c) / 160.5(b). Wattage used must be the maximum rated for the luminaire, not the lamp.
G. MODULAR LIGHTING SYSTEMS
This section does not apply to this project.
CERTIFICATE OF COMPLIANCE NRCC-LTI-E
Project Name: NPS GOGA Stinson Beach Report Page: (Page 4 of 8)
Date Prepared: 2024-02-20T15:28:51-05:00
Generated Date/Time: Documentation Software: Energy Code Ace
CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220101
Compliance ID: 177993-0224-0007 Report Generated: 2024-02-20 12:28:54
H. INDOOR LIGHTING CONTROLS (Not including PAFs) This table includes lighting controls for conditioned and unconditioned spaces.
Building Level Controls
01 02 03
Mandatory Demand Response 110.12(c) Shut-off controls 130.1(c) / 160.5(b)4C Field Inspector Pass Fail
NA < 4,000W subject to multilevel See Area/Space Level Controls Area Level Controls
04 05 06 07 08 09 10 11 12
Area Description Complete Building or Area Category Primary Function
Area
Manual Area Controls 130.1(a) / 160.5(b)4A
Multi-Level Controls 130.1(b) / 160.5(b)4B
Shut-Off Controls 130.1(c) // 160.5(b)4C
Primary/Sky lit
Daylighting 130.1(d) / 160.5(b)4D
Secondary Daylighting 130.1(d) / 160.5(b)4D
Interlocked Systems 140.6(a)1/ 170.2(e)2A
Field Inspector
Pass Fail
KITCHEN Kitchen/ Food Preparation Readily Accessible Dimmer Occupancy Sensor NA: General
Ltg < 120W NA: General Ltg < 120W No
RESTROOM Restroom Readily Accessible NA: Restrooms Occupancy Sensor NA: Not daylit zone NA: Not daylit zone No
STORAGE Storage - MF common areas Readily Accessible
NA: Enclosed area <100SF Occupancy Sensor NA: Not daylit zone NA: Not daylit zone No
HALLWAY Corridor Readily Accessible
NA: General Ltg <= 0.5W/SF Occupancy Sensor NA: Not daylit zone NA: Not daylit zone No
GARAGE General Commercial Industrial Work Area High Bay
Readily Accessible Dimmer Occupancy Sensor NA: Not daylit zone NA: Not daylit zone No
STAIRWELL Stairwell Readily Accessible
NA: General Ltg <= 0.5W/SF Occupancy Sensor NA: Not daylit zone NA: Not daylit zone No
BREAK AREA Lounge Readily Accessible Dimmer Occupancy Sensor NA: General
Ltg < 120W NA: General Ltg < 120W No
WATCH TOWER All Other Space Types Readily Accessible
NA: Enclosed area <100SF Occupancy Sensor NA: General
Ltg < 120W NA: General Ltg < 120W No
CERTIFICATE OF COMPLIANCE NRCC-LTI-E
Project Name: NPS GOGA Stinson Beach Report Page: (Page 5 of 8)
Date Prepared: 2024-02-20T15:28:51-05:00
Generated Date/Time: Documentation Software: Energy Code Ace
CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220101
Compliance ID: 177993-0224-0007 Report Generated: 2024-02-20 12:28:54
H. INDOOR LIGHTING CONTROLS (Not including PAFs)
Plan Sheet Showing Daylit Zones:
I. LIGHTING POWER ALLOWANCE: COMPLETE BUILDING OR AREA CATEGORY METHODS
Each area complying using the Complete Building or Area Category Methods per 140.6(b) are included in this table. Column 06 indicates if additional lighting power allowances per 140.6(c) or adjustments per 140.6(a) are being used .
Conditioned Spaces
01 02 03 04 05 06
Area Description Complete Building or Area Category Primary Function Area
Allowed Density (W/ft2) Area (ft2) Allowed Wattage
(Watts) Additional Allowance / Adjustment Area Category PAF
KITCHEN Kitchen/ Food Preparation 0.95 574 545.3 No No RESTROOM Restroom 0.65 410 266.5 No No STORAGE Storage - MF common areas 0.45 82 36.9 No No HALLWAY Corridor 0.4 211 84.4 No No
GARAGE General Commercial Industrial Work Area High Bay 0.65 623 404.95 No No
STAIRWELL Stairwell 0.6 99 59.4 No No BREAK AREA Lounge 0.55 235 129.25 No No
WATCH TOWER All Other Space Types 0.4 99 39.6 No No TOTALS: 2,333 1,566.3 See Tables J, or P for detail
J. ADDITIONAL ALLOWANCE: AREA CATEGORY METHOD QUALIFYING LIGHTING SYSTEM
CERTIFICATE OF COMPLIANCE NRCC-LTI-E
Project Name: NPS GOGA Stinson Beach Report Page: (Page 6 of 8)
Date Prepared: 2024-02-20T15:28:51-05:00
Generated Date/Time: Documentation Software: Energy Code Ace
CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220101
Compliance ID: 177993-0224-0007 Report Generated: 2024-02-20 12:28:54
K. TAILORED METHOD GENERAL LIGHTING POWER ALLOWANCE
This section does not apply to this project.
L. ADDITIONAL LIGHTING ALLOWANCE: TAILORED WALL DISPLAY
This section does not apply to this project.
M. ADDITIONAL LIGHTING ALLOWANCE: TAILORED FLOOR AND TASK LIGHTING
This section does not apply to this project.
N. ADDITIONAL LIGHTING ALLOWANCE: TAILORED DECORATIVE /SPECIAL EFFECTS
This section does not apply to this project.
O. ADDITIONAL LIGHTING ALLOWANCE: TAILORED VERY VALUABLE MERCHANDISE
This section does not apply to this project.
P. POWER ADJUSTMENT: LIGHTING CONTROL CREDIT (POWER ADJUSTMENT FACTOR (PAF))
This section does not apply to this project.
Q. RATED POWER REDUCTION COMPLIANCE FOR ONE-FOR-ONE ALTERATIONS
This section does not apply to this project.
R. 80% LIGHTING POWER FOR ALL ALTERATIONS - CONTROLS EXCEPTIONS
CERTIFICATE OF COMPLIANCE NRCC-LTI-E
Project Name: NPS GOGA Stinson Beach Report Page: (Page 7 of 8)
Date Prepared: 2024-02-20T15:28:51-05:00
Generated Date/Time: Documentation Software: Energy Code Ace
CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220101
Compliance ID: 177993-0224-0007 Report Generated: 2024-02-20 12:28:54
S. DAYLIGHT DESIGN POWER ADJUSTMENT FACTOR (PAF)
This section does not apply to this project.
T. DWELLING UNIT LIGHTING
This section does not apply to this project.
U. DECLARATION OF REQUIRED CERTIFICATES OF INSTALLATION
Selections have been made based on information provided in this document. If any selections have been changed by permit applicant, an explanation should be included in Table E.
Additional Remarks. These documents must be provided to the building inspector during construction and can be found online
Form/Title
NRCI-LTI-E - Must be submitted for all buildings
V. DECLARATION OF REQUIRED CERTIFICATES OF ACCEPTANCE
Selections have been made based on information provided in this document. If any selections have been changed by the permit applicant, an explanation should be included in Table E.
Additional Remarks. These documents must be provided to the building inspector during construction and any with "-A" in the form name must be completed through an Acceptance Test Technician Certification Provider (ATTCP). For more information visit: http://www.energy.ca.gov/title24/attcp/providers.html
Form/Title Systems/Spaces To Be Field Verified
NRCA-LTI-02-A - Must be submitted for occupancy sensors and automatic time switch controls. KITCHEN; RESTROOM;
STORAGE; HALLWAY;
GARAGE; STAIRWELL; BREAK
AREA; WATCH TOWER
CERTIFICATE OF COMPLIANCE NRCC-LTI-E
Project Name: NPS GOGA Stinson Beach Report Page: (Page 8 of 8) Project Address: Date Prepared: 2024-02-20T15:28:51-05:00
Generated Date/Time: Documentation Software: Energy Code Ace
CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220101
Compliance ID: 177993-0224-0007 Report Generated: 2024-02-20 12:28:54
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
I certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Brian Flynn
Documentation Author Signature:
Company:
AE Design
Signature Date:
Address: CEA/ HERS Certification Identification (if applicable):
City/State/Zip: Phone:
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. The information provided on this Certificate of Compliance is true and correct.
2. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer)
3. The energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.
4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
5. I will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a completed signed copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy.
Responsible Designer Name: Responsible Designer Signature:
Company: Date Signed:
Address: License:
City/State/Zip: Phone:
| Section A - A. GENERAL INFORMATION |
| Section B - B. PROJECT SCOPE |
| Section C - C. COMPLIANCE RESULTS |
| Section D - D. EXCEPTIONAL CONDITIONS |
| Section E - E. ADDITIONAL REMARKS |
| Section F - F. INDOOR LIGHTING FIXTURE SCHEDULE |
| Section G - G. MODULAR LIGHTING SYSTEMS |
| Section H - H. INDOOR LIGHTING CONTROLS (Not including PAFs) |
| Section I - I. LIGHTING POWER ALLOWANCE: COMPLETE BUILDING OR AREA CATEGORY METHODS |
| Section J - J. ADDITIONAL ALLOWANCE: AREA CATEGORY METHOD QUALIFYING LIGHTING SYSTEM |
| Section K - K. TAILORED METHOD GENERAL LIGHTING POWER ALLOWANCE |
| Section L - L. ADDITIONAL LIGHTING ALLOWANCE: TAILORED WALL DISPLAY |
| Section M - M. ADDITIONAL LIGHTING ALLOWANCE: TAILORED FLOOR AND TASK LIGHTING |
| Section N - N. ADDITIONAL LIGHTING ALLOWANCE: TAILORED DECORATIVE /SPECIAL EFFECTS |
| Section O - O. ADDITIONAL LIGHTING ALLOWANCE: TAILORED VERY VALUABLE MERCHANDISE |
| Section P - P. POWER ADJUSTMENT: LIGHTING CONTROL CREDIT (POWER ADJUSTMENT FACTOR (PAF)) |
| Section Q - Q. RATED POWER REDUCTION COMPLIANCE FOR ONE-FOR-ONE ALTERATIONS |
| Section R - R. 80% LIGHTING POWER FOR ALL ALTERATIONS - CONTROLS EXCEPTIONS |
| Section S - S. DAYLIGHT DESIGN POWER ADJUSTMENT FACTOR (PAF) |
| Section T - T. DWELLING UNIT LIGHTING |
| Documentation Author's Declaration Statement |
File details come from the government source that posted it. Updated .