B08_Attachment_11_-_AWPA_Standards.pdf
PDF 178 KB Posted
- Attached to
- Drydocking of The Steam Paddle Tug EPPLETON HALL Federal contract opportunity
- Solicitation number
- 140P8624Q0049
About this file
This document is an excerpt from the American Wood Protection Association (AWPA) Standard U1-13, which provides specifications for the use category system and treatment requirements for various types of treated wood. The standard defines exposure conditions and service life expectations for wood products based on 5 use categories (UC1-UC5) plus 2 fire retardant categories. It lists standardized preservatives, wood species, and commodity specifications for sawn products, posts, crossties, poles, piling, composites, and other applications. The standard serves as a guide for specifiers and users of treated wood to identify the appropriate preservative and retention levels for specific end-use environments. Key details include descriptions of the use categories, preservative listings, and commodity specifications arranged by wood type and application.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Sol_140P8624Q0049_Amd_0004.pdf | ||
| Sol_140P8624Q0049_Amd_0003.pdf | ||
| Sol_140P8624Q0049_Amd_0002.pdf | ||
| Site_Visit_Sign_In_Sheet_0002.pdf | ||
| Questions_and_Answer_from_Site_Visit_August_9_0002.pdf | ||
| Sol_140P8624Q0049_Amd_0001.pdf | ||
| B08_Attachment_12_-_SSPC_Standards.pdf | ||
| B08_Attachment_9_-_ABS_Section_25.pdf | ||
| B08_Attachment_10_-_WCLIB.pdf | ||
| B08_Attachment_3_-_Eppleton_Hall_Docking_Plan.pdf | ||
| B08_Attachment_8_-_USCGSF_-MSIB_13-01.pdf | ||
| B03_Attachment_13_-_SCA_Wages.pdf | ||
| B08_Attachment_5_-_Eppleton_Hall_NPS_Drawings.pdf | ||
| Sol_140P8624Q0049.pdf | ||
| B08_Attachment_7_-_USCG_NAVIC_7-01.pdf | ||
| B08_Attachment_4_-_Eppleton_Hall_UT_Reports.pdf | ||
| B08_Attachment_2_-_Technical_Specifications.pdf | ||
| B08_Attachment_1-_Price_Schedule.pdf | ||
| B08_Attachment_6_-_Eppleton_Hall_Material_Specifications.pdf |
Show all 19
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ATTACHMENT 11
AMERICAN WOOD PROTECTION
ASSOCIATION STANDARDS FOR
SODIUM BORATE PRESERVATIVES, P5
Exc erp t fr om A
WPA U
1-1
Copyri ght 2
3 A
WPA
All R ights
Res erv ed
U1-13
AMERICAN WOOD PROTEC TION ASSOCIATION STANDARD
© 2013 All Rights Reserved
USE CATEGORY SYSTEM: USER SPECIFICATION FOR TREATED WOOD
Jurisdiction: AWPA Technical Committees T-1, T-2, T-3, T-4, T-8, and T-10
Adopted in 1999, amended in 2000, 2001, 2002, 2003, 2004, 2005, 2006, 2007, 2008, 2009, 2010, 2011, 2012, and 2013.
This Standard was developed by AWPA’s Technical Committees in an open, consensus-based process. Any modifications, deviations, or exceptions to this Standard invalidate any references to this Standard and nullifies any statements of compliance with this Standard.
IMPORTANT: Wood processing and treated wood are regulated by a number of organizations in addition to AWPA (e.g., U.S. EPA, state or local governments). The existence of AWPA Standards for treated products does not imply that all other regulatory bodies recognize or permit the use of the particular combination of preservatives, processes, and/or wood species listed in the AWPA Standards.
1. Introduction to the Use Category System
2. Service Conditions for Use Category Designations
3. Guide to Commodity Specifications for Treated
Wood End Uses
4. Standardized Preservatives
5. Standardized Wood Species
6. Commodity Specifications:
A. Sawn Products B. Posts
C. Crossties and Switchties D. Poles E. Round Timber Piling F. Wood Composites G. Marine (Salt Water) Applications H. Fire Retardants I. Nonpressure Applications J. Nonpressure Composites K. Barrier Protection Systems
SECTION 1: INTRODUCTION TO THE USE CATEGORY SYSTEM
The Use Category System (UCS) of the American Wood Protection Association (AWPA) designates what preservative systems and retentions have been determined to be effective in protecting wood products under specified exposure conditions. The strength of the UCS and its focus is that all wood uses can be placed into one of five major Use Categories that clearly describe the exposure conditions that specific wood products can be subjected to in service. The major Use Categories are further broken down into sub-categories to define the associated degree of biodegradation hazard and product service life expectations for specific products and exposure conditions. In addition to the five Use Categories for biodeterioration, there is a sixth and separate Use Category for fire retardant applications. The Use Category designations are described in detail in Section 2 below. The Use Category system is designed to help specifiers and product users locate the appropriate AWPA Standards that provide listing of preservatives deemed acceptable for specific products and end-use environments.
The user of the AWPA Standard U1 should first become familiar with the major differences between the Use Categories and the expected service conditions as described in Section 2. This information is then used in conjunction with Section 3: Guide to Treated Wood End Uses to determine the specific Commodity Specification of the Standard that lists the appropriate preservative requirements for that use. When purchasing under the Use Category System, material orders should include the specific commodity, Use Category designation, Standard U1 Commodity Specification, wood species, preservative and any special requirements such as pre-or post-treatment preparations (including conditioning and drying). Wherever practicable, material should be manufactured in its final form prior to treatment to eliminate the necessity for subsequent cutting or boring of the treated wood. Risk assessment documents and models (e.g., Best Management Practices) have been developed by the Western Wood Preservers Institute (www.wwpinstitute.org) for the use of CCA, ACZA, Creosote, Pentachlorophenol and ACQ treated wood in aquatic environments. Projects calling for large volumes of treated wood immersed in (i.e., below the splash zone) poorly circulating bodies of water should be evaluated on an individual basis using risk assessment procedures. There are a number of other AWPA Standards that complement Standard U1 for wood treated with preservative systems. These include:
Standard T1: Use Category System: Processing and Treatment Standard, that governs the preservative retention and penetration requirements, processing limitations, quality control and inspection requirements for treated wood.
Miscellaneous (M) Standards for Quality control and inspection items Analytical (A) Standards to determine conformance of preservative systems, penetration, and retention. Refer to the Introduction to this Book of Standards at the front of this edition for additional information.
t fr om A
WPA U
1-1
Copyri ght 2
3 A
WPA
All R ights
Res erv ed
U1-13 USE CATEGORY SYSTEM: USER SPECIFICATION FOR TREATED WOOD
© 2013
SECTION 2: SERVICE CONDITIONS FOR USE CATEGORY DESIGNATIONS
The following is a breakdown of the Use Categories used by AWPA to describe the exposure conditions that wood may be subject to in service. This is also given in table form on the next page to summarize the major differences between Use Category groupings.
UC1 INTERIOR/DRY
Wood and wood based materials used in interior construction not in contact with the ground or foundations. Such products are protected from weather and interior sources of water such as leaking plumbing, condensate, pools and spas. Examples are interior furniture, construction furnishings, and millwork.
UC2 INTERIOR/DAMP
Wood and wood based materials used for interior construction that are not in contact with ground, but may be subject to dampness. These products are continuously protected from the weather but may be exposed to occasional sources of moisture.
Examples are interior beams, timbers, flooring, framing, millwork and sill plates.
UC3 ABOVE GROUND (Exterior)
UC3A ABOVE GROUND Protected -- Wood and wood-based materials used in exterior construction that are coated and not in contact with the ground. Such products may be exposed to the full effects of weather, such as vertical exterior walls or other types of construction that allows water to quickly drain from the surface. Examples are coated millwork, siding and trim.
UC3B ABOVE GROUND Exposed -- Wood and wood based materials used in exterior construction and not in contact with the ground. Materials do not require an exterior coating, but may be finished to achieve a desired aesthetic appearance.
Materials are used for a variety of applications in either horizontal and vertical positions such as decking, sills, walkways, railings and fence pickets.
Note: Retentions above the minimum specified for materials in this use category may be required for products such as crossarms where the individual components are difficult to maintain, repair or replace and are critical to the performance and safety of the entire system.
UC4 GROUND CONTACT
UC4A GROUND CONTACT General Use -- Wood and wood-based materials used in contact with the ground, fresh water, or other situations favorable to deterioration.
Examples are fence posts, deck posts, guardrail posts, structural lumber, timbers and utility poles located in regions of low natural potential for wood decay and insect attack.
UC4B GROUND CONTACT Heavy Duty -- Wood and wood-based material used in contact with the ground either in severe environments, such as horticultural sites, in climates with a high potential for deterioration, in critically important components such as utility poles, building poles and permanent wood foundations, and wood used in salt water splash zones. This category includes utility poles used in moist temperate climates.
UC4C GROUND CONTACT Extreme Duty --Wood and wood based materials used in contact with the ground either in very severe environments or climates demonstrated to have extremely high potential for deterioration, in critical structural components such as land and fresh water piling and foundation piling, and utility poles located in semi-tropical or tropical environments.
UC5 MARINE USE
UC5A MARINE USE Northern Waters -- Wood and wood based materials exposed to salt and brackish water which includes Long Island, NY and northward on the east coast and north of San Francisco on the west coast to the extent that the marine borers can attack them. This includes areas where Limnoria quadripunctata is present, but lacks those borers listed under UC5B and UC5C. This includes piling and bracing, bulk-heading or other construction that is actually exposed at some time during the year to salt water.
UC5B MARINE USE Central Waters -- Wood and wood based materials exposed to salt and brackish water south of Long Island, NY to the southern border of Georgia on the east coast and south of San Francisco on the west coast to the extent that the marine borers can attack them. This includes areas where creosote tolerant Limnoria tripunctata is present, but lacks those borers listed under UC5C. This includes piling and bracing, bulk-heading or other construction that is actually exposed at some time during the year to salt water.
UC5C MARINE USE Southern Waters -- Wood and wood based materials exposed to salt and brackish water south of Georgia and along the gulf coasts in the eastern U.S., as well as Hawaii and Puerto Rico, to the extent that the marine borers can attack them. This includes areas where Martesia and Sphaeroma are present. This includes piling and bracing, bulk-heading or other construction that is actually exposed at some time during the year to salt water.
UCF FIRE RETARDANT
UCFA FIRE RETARDANT Interior -- Wood and wood based materials intended for fire protection and used in interior construction where wood material is not in contact with the ground and is protected from exterior weather.
UCFB FIRE RETARDANT Exterior -- Wood and wood based materials intended for fire protection and used in exterior construction that is not in contact with the ground or with foundations, but may be exposed to full effects of weather such as intermittent rain, dew, sunlight and wind.
Materials are applied to vertical, exterior walls, inclined roof surfaces or other types of construction that allow water to quickly drain from the surface.
t fr om A
WPA U
1-1
Copyri ght 2
3 A
WPA
All R ights
Res erv ed
U1-13 USE CATEGORY SYSTEM: USER SPECIFICATION FOR TREATED WOOD
TABLE 2-1 SERVICE CONDITIONS FOR USE CATEGORY DESIGNATIONS
USE
CATEGORY
SERVICE CONDITIONS USE ENVIRONMENT
COMMON AGENTS OF
DETERIORATION
TYPICAL
APPLICATIONS
UC1
INTERIOR/
DRY
Interior construction Above Ground
Dry
Continuously protected from weather or other sources of moisture
Insects only Interior construction and furnishings
UC2
INTERIOR/
DAMP
Interior construction Above Ground
Damp
Protected from weather, but may be subject to sources of moisture
Decay fungi and insects Interior construction
UC3A
ABOVE
GROUND
Protected
Exterior construction Above Ground
Coated & rapid water runoff
Exposed to all weather cycles, not exposed to prolonged wetting
Decay fungi and insects Coated millwork, siding and trim
UC3B
ABOVE
GROUND
Exposed
Exterior construction Above Ground
Uncoated or poor water run-off
Exposed to all weather cycles including prolonged wetting
Decay fungi and insects Decking, deck joists, railings, fence pickets, uncoated millwork
UC4A
GROUND
CONTACT
General Use
Ground Contact or Fresh Water Non-critical components
Exposed to all weather cycles, normal exposure conditions
Decay fungi and insects Fence, deck, and guardrail posts, crossties & utility poles
(low decay areas)
UC4B
GROUND
CONTACT
Heavy Duty
Ground Contact or Fresh Water Critical components or difficult replacement
Exposed to all weather cycles, high decay potential includes salt water splash
Decay fungi and insects with increased potential for biodeterioration
Permanent wood foundations, building poles, horticultural posts, crossties & utility poles (high decay areas)
UC4C
GROUND
CONTACT
Extreme Duty
Ground Contact or Fresh Water Critical structural components
Exposed to all weather cycles, severe environments extreme decay potential
Decay fungi and insects with extreme potential for biodeterioration
Land & Freshwater piling, foundation piling, crossties & utility poles (severe decay areas)
UC5A
MARINE USE
Northern Waters
Salt or brackish water and adjacent mud zone which includes Long Island, NY and northward, north of San Francisco
Continuous marine exposure (salt water)
Salt water organisms Piling, bulkheads, bracing
UC5B
MARINE USE
Central Waters
Salt or brackish water and adjacent mud zone south of Long Island, NY to the southern border of
GA, south of San Francisco
Continuous marine exposure (salt water)
Salt water organisms Including creosote tolerant
Limnoria tripunctata
Piling, bulkheads, bracing
UC5C
MARINE USE
Southern Waters
Salt or brackish water and adjacent mud zone
South of GA, Gulf Coast, Hawaii, and Puerto Rico
Continuous marine exposure (salt water)
Salt water organisms Including
Martesia, Sphaeroma
Piling, bulkheads, bracing
UCFA
FIRE
RETARDANT
Interior
Fire protection as required by codes
Above Ground Interior construction
Continuously protected from weather or other sources of moisture
Fire Roof sheathing, roof trusses, studs, joists, paneling
UCFB
FIRE
RETARDANT
Exterior
Fire protection as required by codes
Above Ground Exterior construction
Subject to wetting Fire Vertical exterior walls, inclined roof surfaces or other construction which allows water to quickly drain t fr om A
WPA U
1-1
Copyri ght 2
3 A
WPA
All R ights
Res erv ed
U1-13 USE CATEGORY SYSTEM: USER SPECIFICATION FOR TREATED WOOD
SECTION 3: GUIDE TO COMMODITY SPECIFICATIONS FOR TREATED WOOD END USES
Section 6 of the UCS-U1 Standard lists standardized preservative systems and required retentions for specific commodities and end-uses. This section is designed to help direct users and specifiers to the governing sub-section of Section 6 for the treated wood application, and to help identify the appropriate Use Category for the intended use. Some commodities may require a retention for a specific application beyond that suggested by Section 2 of this Standard due to the critical nature of their use. Note that this section is only intended to be a guide. The designer should use their best judgment to determine the appropriate specifications for a particular use.
Table 3-1 Guide to commodity specifications for treated wood end uses, arranged by use.
Use Commodity Specification Commodity Use Exposure Category Section Special Reqs.
Bender Board General Ground Contact or Fresh Water 4A A Bulkhead Sheathing Non-Marine Ground Contact or Fresh Water 4A A
Marine Brackish or Salt Water 5A-5B-5C G 6.1-6.4 Cant Strips Building Construction Above Ground 3B A 4.1 Composite Lumber Structural Above Ground, Exterior 3B F (PSL & LVL) Highway Structural, General Ground Contact or Fresh Water 4A F
Highway Structural, Important or High Decay
Ground Contact or Fresh Water 4B F
Highway Structural, Critical or Severe Decay
Ground Contact or Fresh Water 4C F
Cribbing Highway Ground Contact or Fresh Water 4C A Crossarms, Sawn General Use Above Ground, Exterior 3B A 4.5 Critical or Hard to Replace Above Ground, Exterior 4A Crossties, Switchties General Ground Contact or Fresh Water 4A C
Important and/or High Decay Ground Contact or Fresh Water 4B C Critical and/or Severe Decay Ground Contact or Fresh Water 4C C
Decking Painted/Unpainted Above Ground, Exterior 3B A Building Construction, General Ground Contact or Fresh Water 4A A Highway Bridge Structural, Critical/Severe Decay
Above Ground 4B, 4C A 4.3
Decks, Residential Decking (Painted/Unpainted) Above Ground, Exterior Joists 3B A Railing Components Joists Ground Contact or Fresh Water
4A A
Support Posts (Sawn) Expansion Boards General Ground Contact or Fresh Water 4A A Fascia Boards Painted/Coated Above Ground, Exterior 3A A
Unpainted Above Ground, Exterior 3B A Fence Pickets Painted/Coated Above Ground, Exterior 3A A
Unpainted Above Ground, Exterior 3B A Fence Rail Painted/Coated Above Ground, Exterior 3A A
Unpainted Above Ground, Exterior 3B A Stockyard, Agricultural Above Ground, Exterior 4A A
Floor Plate Building Construction Above Ground, Potentially Wet 3B A Flooring Above Ground, Interior Protected, Insect Only 1 A 4.1
Above Ground, Interior Protected, Damp 2 A 4.1 Residential/Commercial, Veranda Above Ground, Exterior 3B A 4.1
Flooring, block Above Ground Low Humidity 2 A Above Ground High Humidity 3A A Furniture Indoor Protected, Insect Only 1 A
Outdoor Above Ground, Exterior 3B A Outdoor Ground Contact 4A A
Furring Strips Indoor Above Ground, Damp 2 A Outdoor Above Ground 3B A Gazebo Material Painted/Coated Above Ground, Exterior 3A A
Unpainted Above Ground, Exterior 3B A t fr om A
WPA U
1-1
Copyri ght 2
3 A
WPA
All R ights
Res erv ed
U1-13 USE CATEGORY SYSTEM: USER SPECIFICATION FOR TREATED WOOD
Table 3-1 Guide to commodity specifications for treated wood end uses, arranged by use. (cont.)
Use Commodity Specification
Commodity Use Exposure Category Section Special Reqs.
Glue Laminated Above Ground, Interior Protected, Insect Only 1 F Beams Above Ground, Interior Protected, Damp 2 F
Above Ground Structural (Painted/Unpainted)
Exterior 3B F
General Structural, Highway Structural Non-Critical
Ground Contact or Fresh Water, Low Decay
4A F
Highway Important Structural or Saltwater Splash
Ground Contact or Fresh Water, High Decay
4B F
Highway Critical Structural Ground Contact or Fresh Water, Severe Decay
4C F
Handrails/Guardrails Highway Construction Above Ground, Exterior 3B A 4.3 Joists Above Ground, Interior Insect Only 1 A 4.1
Above Ground, Interior Above Ground, Damp 2 A 4.1 Building Construction Above Ground, Exterior 3B A Building Construction Ground Contact/Fresh Water 4A A
Laminated Veneer Lumber (LVL)
See Composite Lumber
Landscape Ties General Ground Contact or Fresh Water 4A A Lattice Painted/Unpainted Above Ground, Exterior 3B A Lumber/Timbers Above Ground, Interior Insect Only 1 A 4.1
Above Ground, Interior Wood Exposed to Dampness 2 A 4.1 Above Ground, Exterior, Coated/Painted
All Applications 3A
General, Including Agriculture/Farms
Above Ground, Exterior, Uncoated 3B A
Food Harvest and Storage Above Ground, Exterior A Roof Decking, Flooring/Subflooring
Above Ground, Exterior A 4.1
Food Contact Above Ground, Exterior A General, Including Retaining Walls, Edging, Agri-/Mariculture, Boats, Furniture, Gazebos, Compost/ Plant/Mushroom Boxes, Flumes
Ground Contact or Fresh Water 4A A
Fire Escapes, Exterior Exposed Above Ground and Ground Contact A Wet Industrial Processing Areas Above Ground and Ground Contact A Cooling Towers Fresh Water Contact A 4.4 Brine Storage, Highway Construction Materials
Ground Contact or Fresh Water B 4.1
Playground Equipment Ground Contact or Fresh Water B 4.3 Permanent Wood Foundation Ground Contact and Above Ground 4B A 4.2 Highway Construction, Residential/Business Structural Support
Ground Contact or Fresh Water A 4.3
Crib Walls, Retaining Walls, Important Structural, Greenhouse
Ground Contact or Fresh Water A
Marine Out of Water and Above Ground
Salt Water Splash A G-2.9
Marine Out of Water and Ground Contact
Salt Water Splash 4C A G-2.9
Aquaculture Fresh Water A Residential/Business Structural Support
Ground Contact or Fresh Water
Marine, Aqua/Mariculture, Highway, Boats
Brackish or Salt Water 5A-5B-5C G 6.1-6.4
Fire Retardant, Fire Protection Interior FA H Fire Retardant, Fire Protection Exterior FB H t fr om A
WPA U
1-1
Copyri ght 2
3 A
WPA
All R ights
Res erv ed
U1-13 USE CATEGORY SYSTEM: USER SPECIFICATION FOR TREATED WOOD
Commodity Use Exposure Category Section Special Reqs.
Millwork, Trim Above Ground, Interior Insect Only 1 A 4.1 Above Ground, Interior Above Ground, Damp 2 A 4.1 Painted/Coated Above Ground, Exterior 3A A 4.1 Unpainted Above Ground, Exterior 3B A
Parallel Strand Lumber (PSL)
See Composite Lumber
Pergola Pergola Ground Contact or Fresh Water 4A A Piles, Foundation Building Construction, Completely Embedded in Soil Ground Contact 4C E
Piles, Round Highway Construction Ground Contact or Fresh Water 4C E Marine/Highway Construction Brackish or Salt Water 5A-5B-5C G 6.1-6.4
Piles, Sawn Residential/Business Structural Support
Ground Contact or Fresh Water 4B A
Residential/Business Structural Support, Critical
Ground Contact or Fresh Water 4C A
Plywood Above Ground, Interior, Subfloor Above Ground, Damp 2 F General, Including Agriculture/Farms
Above Ground, Exterior 3B F
Food Harvest-Storage-Contact Above Ground, Exterior F Roof Decking, Flooring/Subflooring
Above Ground, Exterior F 2.6
General: Including Edging, Agriculture, Mariculture, Boats, Furniture, Gazebos, Compost/Plant/Mushroom Boxes, Flumes
Ground Contact or Fresh Water 4A F
Brine Storage, Highway Construction Materials
Ground Contact or Fresh Water F B-4.1
Wet Industrial Processing Areas Ground Contact or Fresh Water F Fire Escapes, Exterior Exposed Above Ground and Ground Contact F Marine Salt Water Splash 4B F Permanent Wood Foundation Ground Contact and Above Ground A 4.2 Marine/Highway Construction, Boat Building
Brackish or Salt Water 5A-5B-5C G
Fire Retardant, Fire Protection Interior FA H Fire Retardant, Fire Protection Exterior FB H
Poles (Round) Agricultural Use, Utility Ground Contact or Fresh Water, Low Decay
4A D
Agriculture, Utility, Highway Construction, Lighting
Ground Contact or Fresh Water, Moderate Decay
4B D
Building Structural Ground Contact or Fresh Water 4B B 4.4 Utility, Lighting Ground Contact or Fresh Water, High Decay 4C D
Poles (Sawn) Agricultural/Farm Ground Contact or Fresh Water 4A A Structural Building Ground Contact or Fresh Water, Moderate Decay 4B A
Poles (Glue Laminated)
Utility Poles Ground Contact or Fresh Water, Low or Moderate Decay
4A/4B D 6
Utility Poles Ground Contact or Fresh Water, High Decay
4C D 6 t fr om A
WPA U
1-1
Copyri ght 2
3 A
WPA
All R ights
Res erv ed
U1-13 USE CATEGORY SYSTEM: USER SPECIFICATION FOR TREATED WOOD
Commodity Use Exposure Category Section Special Reqs.
Posts Round, ½ & ¼ Round
General, Fence, Highway Construction Including Guide, Sign and Sight
Ground Contact or Fresh Water 4A B
Playground Equipment Ground Contact or Fresh Water 4A B Highway Construction, Including Guardrail Posts, Spacer Blocks
Ground Contact or Fresh Water, Moderate Decay
4B B
Building Construction Ground Contact or Fresh Water 4B B 4.4 Agricultural Used as Round Structural Members
Ground Contact or Fresh Water, Moderate Decay
4B B 4.2.1
Brine Storage, Highway Ground Contact or Fresh Water, Moderate Decay
4B B 4.1.2
Posts (Sawn 4 Sides) General, Fence, Deck Support Ground Contact or Fresh Water 4A A Highway Construction, General Ground Contact or Fresh Water 4A A Playground Equipment Ground Contact or Fresh Water 4A B 4.3 Agricultural Use, Spacer Blocks Ground Contact or Fresh Water, Moderate Decay 4B A
Important Building Structural Ground Contact or Fresh Water 4C A Purlins Above Ground, Interior Insect Only 1 A
Above Ground, Damp 2 Painted/Coated Above Ground, Exterior 3A A Unpainted Above Ground, Exterior 3B A
Shakes and Shingles Painted or Unpainted Above Ground, Exterior 3B A 4.6 Siding (Beveled or Not)
Painted/Coated Above Ground, Exterior 3A A 4.1
Unpainted Above Ground, Exterior 3B A Sill Plates Interior Above Ground, Damp 2 A 4.1 Skirtboard Post Frame Construction Ground Contact 4A A Stakes (Sawn 4 Sides)
Grape, Agriculture Ground Contact/Fresh Water 4A A
Structural Composite Lumber
See Composite Lumber
Studs Building Construction, Interior Insect Only 1 A 4.1 Building Construction, Interior Wood Exposed to Dampness 2 A 4.1 Ties Mine and Bridge Ground Contact or Fresh Water 4A B Brackish or Salt Water 5A-5B-5C G 6.1-6.4 Trusses Roof Insect Only 1 A 4.1 Roof Wood Exposed to Dampness 2 A 4.1 Floor Above Ground 3B A 4.1 Utility Poles Distribution, Transmission, Laminated, General Ground Contact or Fresh Water 4A D
Distribution, Transmission, Laminated, Important
Ground Contact or Fresh Water, High Decay
4B D
Distribution, Transmission, Laminated, Critical
Ground Contact or Fresh Water, Severe Decay
4C D
Veranda supports Veranda Supports Ground Contact or Fresh Water 4A A t fr om A
WPA U
1-1
Copyri ght 2
3 A
WPA
All R ights
Res erv ed
U1-13 USE CATEGORY SYSTEM: USER SPECIFICATION FOR TREATED WOOD
SECTION 4: STANDARDIZED PRESERVATIVES
Table 1. Preservatives for Pressure Treatment Processes
Preservative Abbreviation
P Standard Reference
Preservative Retention
Basis, as Preservative Carrier
Oilborne and Creosote-Based
CPF P8/P9 Chlorpyrifos (use cobiocide Chlorothalonil) Not Available Hydrocarbon Solvent
CR P1/P13 Creosote Creosote Not applicable
CR-S P2 Creosote Solution Creosote Not applicable
CR-PS P3 Creosote-Petroleum Solution Creosote Hydrocarbon Solvent
Cu8 P8/P9 Oxine Copper Copper Light Hydrocarbon Solvent
CuN P8/P9 Copper Naphthenate Copper Hydrocarbon Solvent
PCP-A P8/P9 Pentachlorophenol (Penta) Solvent A PCP Hydrocarbon Solvent
PCP-C P8/P9 Pentachlorophenol (Penta) Solvent C PCP Light Hydrocarbon Solvent
PCP-G P8/P9 Pentacholorphenol (Penta) Solvent G PCP High Boiling Hydrocarbon
Solvent
Waterborne, Acid-based
ACC P5 Acid Copper Chromate Metal Oxides Water
CCA P5 Chromated Copper Arsenate Type C Metal Oxides Water
Waterborne, Alkali-based (amine/ammonia)
ACQ-A P5 Alkaline Copper Quat Type A CuO + Quat Water
ACQ-B P5 Ammoniacal Copper Quat Type B CuO + Quat Water
ACQ-C P5 Alkaline Copper Quat Type C CuO + Quat Water
ACQ-D P5 Alkaline Copper Quat Type D CuO + Quat Water
ACZA P22 Ammoniacal Copper Zinc Arsenate Metal Oxides Water
CA-B P5 Copper Azole Type B Cu + azole Water
CA-C P5 Copper Azole Type C Cu + azoles Water
CX-A P5 Copper HDO Type A CuO + H3BO3 + HDO Water
KDS P55 Alkaline Copper Betaine CuO + DPAB + H3BO3 Water
KDS-B P56 Alkaline Copper Betaine Type B CuO + DPAB Water
Waterborne, Other
CDDC P5
Copper bis(dimethyldithiocarbamate)
CDDC
Copper Water
CuN-W P5 Waterborne Copper Naphthenate Copper Water
EL2 P5
4,5-dichloro-2-n-octyl-4-isothiazolin-3-one (DCOI) and 2-Imidazolidinimine, 1-((6-chloro-3-pyridinyl)methyl)-nitro (Imidacloprid)
DCOI +
Imidacloprid
Water
PTI P5 Propiconazole Tebuconazole Imidacloprid Propiconazole Tebuconazole Imidacloprid
Water
SBX P5 Inorganic Boron (SBX) B2O3 Water t fr om A
WPA U
1-1
Copyri ght 2
3 A
WPA
All R ights
Res erv ed
U1-13 USE CATEGORY SYSTEM: USER SPECIFICATION FOR TREATED WOOD
Table 2. Protectants for Fire-Retardant Treatment Processes
Protectant
P Standard Reference
Protectant Retention Basis Preservative Carrier
FR-1 P49 FR-1 Not Available Water
FR-2 P50 FR-2 Not Available Water
Table 3. Preservatives for Non-Pressure Treatment Processes
P Standard Reference
Preservative Retention Basis Preservative Carrier
Oilborne and Creosote-based
Cu8 P37 Oxine Copper Oxine Copper Hydrocarbon Solvent
CuN P8/P9 Copper Naphthenate Copper Hydrocarbon Solvent
Waterborne, Other
AAC P5/P8 Alkyl Ammonium Compound Not Available Water/Hydrocarbon Solvent
Light Organic Solvent Systems
DCOI
P8/P9 4.5-dichlor-2-N-octyl-4-Isothiazolin-3-one
(Isothiazolin) (Note b) Not Available Light Hydrocarbon Solvent
IPBC P8/P9 3-iodo-2 propynyl butyl carbamate (Note b) Not Available Light Hydrocarbon Solvent
PPZ
P8/P9 1-[2-(4-dichlorophenyl)-4-propyl-1,3-dioxolan-2-Γ L-methyl]-1H-1,2,4-triazole (Propiconazole) (Note b)
Not Available Hydrocarbon Solvent
TEB
P8/P9 Γ-(2(4(chlorophenyl)ethyl-y-(1,1-dimethylethyl)-1H-1,2,4-Triazole-1 Ethanol (Tebuconazole) (Note b)
Not Available Hydrocarbon Solvent
Preservative Added During Manufacture
KDS P57 Alkaline Copper Betaine CuO + DPAB +
H3BO3
Water
ZB P51 Zinc Borate 2ZNO•3B2O3•3.5H2O Not Applicable
Table 4. Preservatives for Thermal Treatment Processes
P Standard Reference
Preservative Retention Basis Preservative Carrier
CuN P8/P9 Copper Naphthenate Copper Hydrocarbon Solvent Type A
PCP-A P8/P9 Pentachlorophenol (Penta) Solvent A PCP Hydrocarbon Solvent Type A
Table 5. Protectants for Nonbiocidal Treatment Processes
Protectant
P Standard Reference
Protectant Retention Basis Protectant Carrier
CM-A P59 Chemical Modification by Acetylation % Bound Acetyl Not Applicable t fr om A
WPA U
1-1
Copyri ght 2
3 A
WPA
All R ights
Res erv ed
U1-13 USE CATEGORY SYSTEM: USER SPECIFICATION FOR TREATED WOOD
SECTION 5: SPECIES AND SPECIES GROUPINGS REFERENCED IN AWPA STANDARDS
The individual species and species groupings listed herein have been included in AWPA Standards because experience has shown that it is possible to treat them successfully, with at least some preservative systems. Listing of a species in these tables does not imply that they are listed for all preservative systems, or that a preservative system appropriate to specific applications is listed or available.
Most species are treated either as sawn or round commodities. Other species groupings, such as those listed in the grade books of various ALSC-accredited grading agencies may contain a mix of species which cannot be readily separated, or properly treated as a whole. Grade marks are an acceptable means of species identification, but only sawn material is grade-marked. To predict treatability, species should be positively identified. The following list includes species groupings that are commonly treated under AWPA Standards, which are described under Notes 1-9 below. Treating of other species groupings should be avoided unless individual species identification can be made by a means acceptable to both buyer and seller. However, acceptance under AWPA Standards is ultimately governed by preservative penetration and retention. The listing of a preservative with a species or species group does not necessarily imply the species or the species group is treated regularly with any specific preservative. Prior to specifying a species for a given application, it should be cross-referenced with specific Commodity Specifications in Section 6, and information should be obtained on the availability of a species preservative combination.
Species Treatability and Variability. Some species are difficult to treat to the requirements of the AWPA Standards even when incised. Individual pieces or lots within a species or species grouping may vary, sometimes significantly in their treatability. Prior to specifying a species or species group for any commodity and preservative, accurate information should be obtained about the treatability and the variability of the species or species group. The recognized common and scientific names of wood species used in AWPA Standards are as follows:
Notes and Footnotes for Species Names and Listings in Section 5 Tables UCS-U1 – Use Category System: User Specification for Treated Wood Products
1 Coastal = West of Summit of Cascade Mountains; Intermountain = East of Cascade Summit.
2 Usually, but not always.
3 For sawn products treated with CCA, Western larch was removed from AWPA Standards with prejudice. For ammoniacal copper preservatives and pentachlorophenol, Western larch was removed from AWPA Standards without prejudice.
Note 1: Southern Pine includes Pinus elliottii (slash), P. echinata (shortleaf), P. palustris (longleaf), P. taeda (loblolly) Note 2: Mixed Southern pine includes all Southern Pine species plus P. virginiana (Virginia) and P. serotina (pond) Note 3: Hem-fir includes Tsuga heterophylla, Abies concolor (white), A. magnifica (Cal. red), A. grandis (grand), A. procera
(nobel) A. amabilis (pacific silver) Note 4: Hem-fir North includes Tsuga heterophylla, Abies amabilis Note 5: Spruce-Pine-Fir includes Abies balsamea, A. lasiocarpa, Picea engelmannii, P. glauca, P. mariana, P. rubrens, Pinus Banksiana, P. contorta Note 6: Spruce-Pine-Fir West (NLGA Grade Rules) is a Western Canadian subset of Spruce-Pine-Fir that is graded Northern
Lumber Grading Association (NLGA) rules, but only by the following Western Canadian agencies: Alberta Forest Products Association (AFPA), Caribou Lumber Manufacturers Association (CLMA), Canadian Mill Services Association (COFI), Interior Lumber Manufacturers Association (ILMA), Northern Forest Products Association (NFPA). It includes Abies Lasiocarpa, Picea engelmannii, P. plauca, P. mariana, Pinus contorta
Note 7: Red Oak includes Quercus rubra, Q. velutina, Q. marilandica, Q. kelloggii, Q falcata, Q. laurifolia, Q. elllipsoidalis, Q. nuttallii, Q. palustris, Q. coccinea, Q. shumardii, Q. laevis, Q. phellos, and Q. nigra.
Note 8: Scots Pine-Ger is Pinus Sylvestris from Germany as certified by a qualified third-party agency.
Note 9: Scots pine-Swe is Pinus sylvestris from Sweden as certified by a qualified third-party agency.
Note 10: Patula Pine is Pinus patula from South Africa and a component of African Montane Pine as certified by a qualified third-party agency.
t fr om A
WPA U
1-1
Copyri ght 2
3 A
WPA
All R ights
Res erv ed
U1-13 USE CATEGORY SYSTEM: USER SPECIFICATION FOR TREATED WOOD
Species Names and Listings in U1 – Use Category System: User Specification for Treated Wood Products Sawn Products
Common Scientific UCS Listings Shakes Cooling Sawn Bridges Name(s) Name(s) UC1&2 UC3 UC4A UC4B UC4C UC5A UC5B UC5C PWF Shingles Towers X-arms highway
Douglas-fir Coastal (Oregon Pine/Red Fir)1 Pseudotsuga menziesii var. menziesii2 X X X X X X X X X X X X Interior (Mountain or Intermountain)1 Pseudotsuga menziesii var. glauca2
Pines Southern Note 1 X X X X X X X X X X X X X Mixed Southern Note 2 X X X X X X X X Ponderosa P. ponderosa X X X X X X X X X X Jack P. banksiana X X X X X Lodgepole P. contorta X X X X X Eastern White (Northern White) P. strobus X X X X X Radiata P. radata X X X X X Caribbean (Ocote, Honduras) P. caribaea, P.oocarpa X X X X X Red (Norway) P. resinosa X X X X X X X X X Spruce Pinus glabra X X X X X Scots Pine – Ger Note 8 X X X X X Scots Pine – Swe Note 9 X X X X X Patula Note 10 X X X X X
Redwood Sequoia sempervirens X X X X X X Hemlocks, Spruces, True Firs
Hem-fir Note 3 X X X X X X X X X X X X Hem-fir North Note 4 X X X X X X X X X X X Western Hemlock Tsuga heterophylla X X X X X X X Eastern Hemlock Tsuga canadensis X X X Subalpine (alpine) Fir Abies lasiocarpa X X X X X X Spruce-Pine-Fir Note 5 X X Spruce-Pine-Fir West Note 6 X X X X X Sitka Spruce Picea sitchensis X X X X X Western White Spruce Picea glauca X X X X X Englemann Spruce Picea engelmannii X X X X X
Western Larch3 Larix occidentalis X Cedars
Western Red Cedar Thuja plicata X X X Alaska Yellow Cedar Chemaecyparis nootkatensis X X Northern White Cedar Thuja occidentalis Incense Cedar Libocedrus decurrens X X
Baldcypress (cypress) Taxodium distichum Hardwoods
Oak all Quercus sp. X X X X X X Red Oak Note 7 X X X Maple Acer sp. X X X Red Maple Acer rubrum Black Gum Nyssa spp. X X X X X X Red (sweet) Gum Liquidambar spp. X X X X X X Hickory Carya spp.
Yellow Poplar Liriodendron tulipifera Mixed Hardwoods All other N.A. hardwood species t fr om A
WPA U
1-1
Copyri ght 2
3 A
WPA
All R ights
Res erv ed
U1-13 USE CATEGORY SYSTEM: USER SPECIFICATION FOR TREATED WOOD
Posts Structural Poles/Posts Crossties Utility Poles
Common Scientific General Farm building switchties General Glue-lam Thermal Name(s) Name(s) UC4A UC4B UC4Bmod UC4B UC4 UC4A UC4B UC4C UC4A-C UC4A&B UC4C
Douglas-fir Coastal (Oregon Pine/Red Fir)1 Pseudotsuga menziesii var. menziesii2 X X X X X X X X X Interior (Mountain or Intermountain)1 Pseudotsuga menziesii var. glauca2 X X Pines Southern Note 1 X X X X X X X X X Mixed Southern Note 2 Ponderosa P. ponderosa X X X X X X X X Jack P. banksiana X X X X X X X Lodgepole P. contorta X X X X X X X Eastern White (Northern White) P. strobus Radiata P. radata X X X X X X X Caribbean (Ocote, Honduras) P. caribaea, P.oocarpa Red (Norway) P. resinosa X X X X X X X X Spruce Pinus glabra
Redwood Sequoia sempervirens
Hemlocks, Spruces, True Firs Hem-fir Note 3 Hem-fir North Note 4 Western Hemlock Tsuga heterophylla X X X Eastern Hemlock Tsuga canadensis Subalpine (alpine) Fir Abies lasiocarpa Spruce-Pine-Fir Note 5 Spruce-Pine-Fir West Note 6 Sitka Spruce Picea sitchensis Western White Spruce Picea glauca Englemann Spruce Picea engelmannii Western Larch3 Larix occidentalis X X X X X X X X X Cedars Western Red Cedar Thuja plicata X X X X X X Alaska Yellow Cedar Chemaecyparis nootkatensis X X X X X Northern White Cedar Thuja occidentalis X X Incense Cedar Libocedrus decurrens
Baldcypress (cypress) Taxodium distichum
Hardwoods Oak all Quercus sp. X Red Oak Note 7 Maple Acer sp.
Red Maple Acer rubrum Black Gum Nyssa spp.
Red (sweet) Gum Liquidambar spp.
Hickory Carya spp. X Yellow Poplar Liriodendron tulipifera Mixed Hardwoods All other N.A. hardwood species X t fr om A
WPA U
1-1
Copyri ght 2
3 A
WPA
All R ights
Res erv ed
U1-13 USE CATEGORY SYSTEM: USER SPECIFICATION FOR TREATED WOOD
Round Glue-Lam Common Scientific Piling Treated after Gluing before Gluing Name(s) Name(s) UC4C UC1-3B UC4A UC4B UC4C UC1-3B UC4A
Douglas-fir Coastal (Oregon Pine/Red Fir)1 Pseudotsuga menziesii var. menziesii2 X X X X X X X Interior (Mountain or Intermountain)1 Pseudotsuga menziesii var. glauca2 X
Pines Southern Note 1 X X X X X X X Mixed Southern Note 2 Ponderosa P. ponderosa X Jack P. banksiana X Lodgepole P. contorta X Eastern White (Northern White) P. strobus Radiata P. radata Caribbean (Ocote, Honduras) P. caribaea, P.oocarpa Red (Norway) P. resinosa X Spruce Pinus glabra
Redwood Sequoia sempervirens
Hemlocks, Spruces, True Firs Hem-fir Note 3 X X X X Hem-fir North Note 4 Western Hemlock Tsuga heterophylla X X X X Eastern Hemlock Tsuga canadensis Subalpine (alpine) Fir Abies lasiocarpa Spruce-Pine-Fir Note 5 Spruce-Pine-Fir West Note 6 Sitka Spruce Picea sitchensis Western White Spruce Picea glauca Englemann Spruce Picea engelmannii
Western Larch3 Larix occidentalis X
Cedars Western Red Cedar Thuja plicata Alaska Yellow Cedar Chemaecyparis nootkatensis Northern White Cedar Thuja occidentalis Incense Cedar Libocedrus decurrens
Baldcypress (cypress) Taxodium distichum Hardwoods
Oak all Quercus sp. X Red Oak Note 7 X X Maple Acer sp.
Red Maple Acer rubrum X X Black Gum Nyssa spp.
Red (sweet) Gum Liquidambar spp.
Hickory Carya spp.
Yellow Poplar Liriodendron tulipifera X X t fr om A
WPA U
1-1
Copyri ght 2
3 A
WPA
All R ights
Res erv ed
U1-13 USE CATEGORY SYSTEM: USER SPECIFICATION FOR TREATED WOOD
Structural Composite Lumber Common Scientific PSL LVL Marine Piling Name(s) Name(s) UC1-3B UC4A UC4B UC1-3B UC4A UC4B UC5A UC5B UC5C
Douglas-fir Coastal (Oregon Pine/Red Fir)1 Pseudotsuga menziesii var. menziesii2 X X X X X X Interior (Mountain or Intermountain)1 Pseudotsuga menziesii var. glauca2
Pines Southern Note 1 X X X X X X X X X Mixed Southern Note 2 Ponderosa P. ponderosa Jack P. banksiana Lodgepole P. contorta Eastern White (Northern White) P. strobus Radiata P. radata Caribbean (Ocote, Honduras) P. caribaea, P.oocarpa Red (Norway) P. resinosa X X X Spruce Pinus glabra
Redwood Sequoia sempervirens
Hemlocks, Spruces, True Firs Hem-fir Note 3 Hem-fir North Note 4 Western Hemlock Tsuga heterophylla Eastern Hemlock Tsuga canadensis Subalpine (alpine) Fir Abies lasiocarpa Spruce-Pine-Fir Note 5 Spruce-Pine-Fir West Note 6 Sitka Spruce Picea sitchensis Western White Spruce Picea glauca Engelmann Spruce Picea engelmannii
Western Larch3 Larix occidentalis
Cedars Western Red Cedar Thuja plicata Alaska Yellow Cedar Chemaecyparis nootkatensis Northern White Cedar Thuja occidentalis Incense Cedar Libocedrus decurrens
Baldcypress (cypress) Taxodium distichum Hardwoods
Oak all Quercus sp.
Red Oak Note 7 Maple Acer sp.
Red Maple Acer rubrum X X X Black Gum Nyssa spp.
Red (sweet) Gum Liquidambar spp.
Hickory Carya spp.
Yellow Poplar Liriodendron tulipifera X X X X X t fr om A
WPA U
1-1
Copyri ght 2
3 A
WPA
All R ights
Res erv ed
U1-13 USE CATEGORY SYSTEM: USER SPECIFICATION FOR TREATED WOOD
SECTION 6: COMMODITY SPECIFICATIONS
Section 6 provides a listing of all AWPA specifications for treated wood commodities. It is organized into a series of sub-sections for major commodity classifications and provides information on the listed preservative systems and species/species groupings that can be treated under AWPA Standards for each Use Category (use exposure condition). Use category descriptions are given in Section 2. If a user/specifier is unsure where to look up a specific commodity and end-use within these tables, they should consult Section 3 of this standard for specific commodity references. In all cases, treated material should be clean of preservative deposits and suitable for its intended end use. Material treated with creosote, creosote solutions, or oil borne preservatives in Use Categories UC1 through UC5 shall be supplied reasonably free of exudate and surface deposits. Material treated with waterborne preservatives shall be supplied free of visible surface deposits. Drying after treatment of material treated with waterborne preservatives is sometimes required or desirable for dimensional stability and should be specified. When drying after treatment is required, the moisture content in each piece of lumber shall not exceed 19% or that allowed by National Grading Rules for the species and size specified to be dried. The moisture content in each piece of plywood shall not exceed 18%.
SUB-SECTIONS OF SECTION 6:
COMMODITY SPECIFICATIONS
A. Sawn Products B. Posts C. Crossties and Switchties D. Poles E. Round Timber Piling F. Wood Composites G. Marine (Salt Water) Applications H. Fire Retardants I. Nonpressure Applications J. Nonpressure Composites K. Barrier Protection Systems
Location of Some Specialized Commodities, not otherwise obvious:
Permanent Wood Foundation (PWF) Both Lumber and Plywood: Commodity Specification A, Section 4.2
Playground Material Lumber, rounds (Posts/poles): Commodity Specification B, Section 4.3
Round Building Poles and Posts
Both poles and posts: Commodity Specification B, Section 4.4
File details come from the government source that posted it. Updated .