B08_-_Attachment_03_-_TIMU_335507_Construction_Drawings.pdf
PDF 14 MB Posted
- Solicitation number
- 140P2026R0081
About this file
These are design drawings for the Kingsley Plantation Shoreline Stabilization project at Timucuan Ecological & Historical Preserve in Jacksonville, Florida, prepared by AECOM Savannah, GA for the National Park Service Denver Service Center. The project number is 140P2026F0010 and includes 27 sheets of construction documents.
The project involves stabilizing the shoreline through a seawall extension using both polyvinyl chloride (PVC) and fiber-reinforced polymer (FRP) composite sheet pile walls. Key structural components include 3/4-inch diameter steel tie rods with hot-dip galvanized and polymer-coated finishes, ASTM A307 Grade A or F1554 Grade 36 materials, stainless steel end plates and fasteners, limestone riprap for scour protection (6 to 12 inches), and woven geotextile filter fabric. The construction is divided into three phases with working limits clearly defined by coordinates. The design includes demolition of existing PVC bulkheads, timber facing boards, and tie rods, with selective salvage of horizontal facing timber boards for reuse. Select structural backfill must be imported to meet specifications with liquid limits and plasticity indices of less than 35 and 15 respectively, compacted to 95 percent maximum dry density per ASTM D698. The site includes temporary access roads stabilized with geotextile fabric and aggregate base material, with contractor deliveries limited to Mondays and Tuesdays. Riprap installation includes saltmeadow cordgrass (Spartina patens) and smooth cordgrass (Spartina alterniflora) plantings at specified elevations and spacing for ecological restoration.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
KINGSLEY PLANTATION
STABILIZE KINGSLEY PLANTATION
SHORELINE WITH SEAWALL EXTENSION
TIMUCUAN ECOLOGICAL & HISTORICAL PRESERVE
UNITED STATES
DEPARTMENT OF THE INTERIOR
Mark Sheet InitialDateREVISION TITLE OF PROJECT
NAME OF PARK
LOCATION WITHIN PARK
REGION
SOUTHEAST
COUNTY
DUVALL
STATE
FLORIDA
DESIGN DRAWINGS
NATIONAL PARK SERVICES
DENVER SERVICE CENTER
DRAWING NO.
PMIS
NO. SHEET
OF
QUALITY DESIGN CERTIFICATION
Prepared in Accordance with Design Development (Title I)
Variance from Design Development (Title I) Approved by Superintendent on
Construction Drawing Not Prededed by Design Development (Title I)
OR
OR
Drawing No.
Date
Project Manager Date
A/E FIRM
PRIME/CIVIL/STRUCT:
335507 01
191524
AECOM
SAVANNAH, GA
9/
/2
:2
AU
TO
C
AD
C
IV
IL
3D
C
:\U se rs \M
K5 \D
C \A
C C
D oc s\
AE
C O
M \E
N V-
AM
ER
(U S)
-6
9- N
PS
T iM U
K
IN
G
SL
EY
P
LA
N
TA
TI
O N
\P ro je ct
F ile s\
TI
M U
\1
6\
C
AD
v
D
R
AW
IN
G
S\ G
EN
ER
AL
\C
O
VE
R .d w g
PROJ. NO. 140P2026F0010
LEGEND
TIMUCUAN ECOLOGICAL & HISTORICAL PRESERVE
JACKSONVILLE
FLORIDA
0 1 21
01 1 2 3
20 200
SCALE OF MILES
SCALE OF MILES
SCALE OF KILOMETERS
INDEX
SHEET SUB
SHEET TITLE OF SHEET
01 N/A COVER SHEET & SHEET INDEX
02 G0.1 GENERAL NOTES
03 G0.2 LEGEND AND ABBREVIATIONS
04 G1.1 OVERALL SITE AND
CONSTRUCTION PHASING PLAN
05 G1.2 KEY PLAN
06 X1.1 DEMOLITION PLAN 1
07 X1.2 DEMOLITION PLAN 2
08 X1.3 DEMOLITION PLAN 3
09 X3.1 DEMOLITION SECTION
10 C1.1 EXISTING CONDITION PLAN 1
11 C1.2 EXISTING CONDITION PLAN 2
12 C1.3 EXISTING CONDITION PLAN 3
13 C1.4 CONTRACTOR SITE ACCESS AND
STAGING AREA
INDEX
SHEET SUB
SHEET TITLE OF SHEET
14 C1.5 SOIL BORING AND BENCHMARK
LOCATION PLAN
15 C1.6 GRADING PLAN 1
16 C1.7 GRADING PLAN 2
17 C1.8 GRADING PLAN 3
18 C3.1 RIP RAP DETAILS
19 C6.1 SOIL BORING LOGS 1
20 C6.2 SOIL BORING LOGS 2
21 S1.1 GENERAL LAYOUT PLAN 1
22 S1.2 GENERAL LAYOUT PLAN 2
23 S1.3 GENERAL LAYOUT PLAN 3
24 S3.1 SHEET PILE WALL SECTION 1
25 S3.2 SHEET PILE WALL SECTION 2
26 S5.1 SHEET PILE WALL DETAILS 1
27 S5.2 SHEET PILE WALL DETAILS 2
THIS ITEM HAS BEEN DIGITALLY SIGNED
AND SEALED BY ANIRBAN BHADRA
PROFESSIONAL ENGINEER, STATE OF
FLORIDA, LICENSE NO. 98875 ON THE
DATE INDICATED HERE. PRINTED COPY
OF THIS DOCUMENT ARE NOT CONSIDERED
SIGNED & SEALED. THE SIGNATURE
MUST BE VERIFIED ON ANY ELECTRONIC
COPIES.
GENERAL NOTES
PROJECT
1. PROJECT NAME:
STABILIZE TIMUCUAN ECOLOGICAL & HISTORICAL PRESERVE - KINGSLEY PLANTATION
SHORELINE WITH SEAWALL EXTENSION.
DRAWINGS
1. THE ISSUED PROJECT DRAWINGS ARE ONE COMPONENT OF THE CONSTRUCTION
CONTRACT DOCUMENTS WHICH IN CONJUNCTION WITH THE PROJECT
SPECIFICATION AND APPLICABLE CODES AND REGULATION ARE INTENDED TO
COVER A COMPLETE PROJECT.
2. WHERE A DETAIL, SECTION, TYPICAL SECTION OR A NOTE IS SHOWN FOR ONE
CONDITION, IT MUST APPLY FOR ALL LIKE OR SIMILAR CONDITIONS, UNLESS NOTED
OR DIRECTED OTHERWISE.
3. REFER TO DIMENSIONS SHOWN WHEN CONSTRUCTING WORK, DO NOT SCALE
DRAWINGS.
SAFETY AND SECURITY
1. PRIOR TO COMMENCING WORK, THE CONTRACTOR MUST FURNISH, ERECT AND
MAINTAIN ALL BARRICADES, FENCINGS, WARNING SIGNS AND MARKING FOR
HAZARDS.
2. THE CONTRACTOR MUST CONTROL HIS OPERATIONS AND THOSE OF HIS
SUBCONTRACTORS AND ALL SUPPLIERS TO ASSURE THE LEAST INCONVENIENCE
TO THE PARK AND ITS VISITORS. UNDER ALL CIRCUMSTANCES SAFETY MUST BE
THE MOST IMPORTANT CONSIDERATION.
3. THE CONTRACTOR MUST CONDUCT ALL OF ITS WORK IN A SAFE MANNER. ALL
WORKS MUST BE PERFORMED IN ACCORDANCE WITH RULES AND REGULATIONS,
PROCEDURES AND SAFE PRACTICES OF NPS, OSHA AND ALL OTHER GOVERNMENT
AGENCIES HAVING JURISDICTION OVER THE PROJECT.
4. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR MAINTAINING SITE SECURITY AND
CONTROLLING ACCESS TO THE WORK AREA.
GENERAL NOTES
1. THE CONTRACTOR MUST FIELD CHECK AND VERIFY ALL ELEVATIONS,
COORDINATES, DIMENSIONS AND EXISTING SITE CONDITIONS PRIOR TO
CONSTRUCTION. DISCREPANCIES MUST BE REPORTED IMMEDIATELY TO THE
CONTRACTING OFFICER.
2. CONTRACTOR MUST SWEEP CLEAN ALL PAVED AREAS SOILED/TRACKED BY
CONSTRUCTION ACTIVITIES AND AS DIRECTED.
3. THE CONTRACTOR MUST FAMILIARIZE HIMSELF WITH THE EXISTING CONDITIONS
AND BE PREPARED TO ADEQUATELY CARE FOR AND SAFEGUARD HIMSELF AND THE
OWNER FROM DAMAGE.
4. ALL MATERIALS MUST BE DELIVERED TO SITE ON MONDAYS AND TUESDAYS ONLY,
WHEN THE PARK IS CLOSED FOR THE VISITORS.
DESIGN CODES, STANDARDS AND REFERENCES
1. INTERNATIONAL BUILDING CODE (IBC) - 2024
2. AMERICAN SOCIETY OF CIVIL ENGINEERS (ASCE) PUBLICATION ASCE/SEI 7-22,
“MINIMUM DESIGN LOADS AND ASSOCIATED CRITERIA FOR BUILDINGS AND OTHER
STRUCTURES”.
3. FLORIDA BUILDING CODE, 2023 8TH EDITION.
4. AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC) "MANUAL OF STEEL
CONSTRUCTION, ALLOWABLE STRESS DESIGN", 15TH EDITION.
5. UNIFIED FACILITIES CRITERIA (UFC) PUBLICATION "UFC 4-152-001 PIERS AND
WHARVES".
6. U.S. ARMY CORPS OF ENGINEERS (USACE) "EM 1110-2-2504 DESIGN OF SHEET PILE
WALLS".
DESIGN CRITERIA
1. LOCATION OF EXISTING STRUCTURES TAKEN FROM LAND SURVEY PERFORMED BY
SSMC ON DECEMBER 2025, AND REPRESENTS THE CONDITIONS OF THE SITE AT THE
TIME OF THE SURVEY.
2. HYDROGRAPHIC SURVEY PERFORMED BY AECOM ON APRIL 2024 REPRESENTS THE
CONDITIONS OF THE SITE AT THE TIME OF THE SURVEY.
3. GEOTECHNICAL FIELD EXPLORATION PERFORMED BY TERRACON CONSULTANT ON
APRIL 2024 REPRESENTS THE SUBSOIL CONDITIONS OF THE SITE AT THE TIME OF
THE INVESTIGATION.
4. ALL ELEVATIONS ARE REFERENCED TO THE NORTH AMERICAN VERTICAL DATUM OF
1988 (NAVD88). HORIZONTAL DATUM IS THE FLORIDA STATE PLANE COORDINATE
SYSTEM (NAD83), EAST ZONE.
5. TIDAL DATUM AND STILL WATER ELEVATIONS AT THE PROJECT SITE ARE DEFINED
AS FOLLOWS:
PROJECT TIDAL ELEVATIONS:
MEAN HIGHER HIGH WATER: EL: +2.24
MEAN HIGH WATER: EL: +1.94
MEAN SEA LEVEL: EL: -0.36
MEAN LOW WATER: EL: -2.84
MEAN LOWER LOW WATER EL: -2.98
TIDAL ELEVATIONS WERE OBTAINED FROM TIDAL STATION ID 872-0186 LOCATED AT
FORT GEORGE ISLAND. THE ELEVATIONS ARE IN FEET AND REFERENCED TO
NAVD88. TIDAL DATA IS PER NOAA AVERAGE BASED ON THE 1983-2001 TIDAL EPOCH.
6. AS BUILT DRAWINGS FOR THE EXISTING BULKHEAD WERE USED IN CONJUNCTION
WITH THE SITE INFORMATION.
7. ALL REFERENCE AND TEMPORARY BENCHMARKS LOCATED AT THE SITE ARE
SHOWN IN THE DRAWING.
DESIGN LOADING
1. STRUCTURE IS DESIGNED FOR THE FOLLOWING NOTED LOAD CRITERIA. LOAD
COMBINATION FOR BULKHEAD ARE IN ACCORDANCE WITH ASCE/SEI 7-22.
2. DEAD LOAD
DEAD LOADS ARE DETERMINED IN ACCORDANCE WITH APPLICABLE ENGINEERING
MANUALS AND ASCE 7-16 AND INCLUDE SELF WEIGHT OF ALL PERMANENT
CONSTRUCTION COMPONENTS.
3. LIVE LOAD
FOLLOWING UNIFORM LIVE LOAD SURCHARGE APPLIED TO THE STRUCTURE.
BULKHEAD: 100 PSF
4. WIND LOAD
WIND SPEED ON BULKHEAD: 130 MPH (ULTIMATE -LEVEL, 3 SEC GUST)
RISK CATEGORY II
5. SEISMIC LOAD
ANALYSIS PROCEDURE IS EQUIVALENT LATERAL FORCE IN ACCORDANCE WITH
ASCE 7-16.
RISK CATEGORY II,
SEISMIC SITE CLASS D
IMPORTANCE FACTOR 1.0
6. CURRENT LOAD
CURRENT SPEED IS ASSUMED TO BE MAXIMUM OF 4 FT/SEC.
7. TEMPERATURE
THERMAL RANGE: ± 40 DEGREE
DEMOLITION
1. ITEMS NOT TO BE SALVAGED MUST BE PROMPTLY REMOVED FROM THE SITE BY
THE CONTRACTOR.
2. ALL DEBRIS RESULTING FROM DEMOLITION AND REMOVAL OPERATIONS MUST BE
REMOVED FROM THE SITE AND DISPOSED OFF LEGALLY BY THE CONTRACTOR AT
THE CONTRACTOR'S EXPENSE.
3. ALL DEMOLISHED AND REMOVED BUT NOT SALVAGED MATERIAL BECOMES THE
PROPERTY OF THE CONTRACTOR UNLESS OTHERWISE NOTED.
4. THE CONTRACTOR MUST NOTIFY CONTRACTING OFFICER OF ANY APPARENT
CONTAMINATED OR HAZARDOUS MATERIALS FOUND.
5. THE CONTRACTOR MUST NOT DISTURB GROUND UNTIL THE GENERAL NPDES
PERMIT IS APPROVED, AND ONCE APPROVED ABIDE BY ITS CONDITION.
6. THERE ARE NO KNOWN UTILITIES PRESENT INSIDE THE WORK LIMIT. THE
CONTRACTOR SHALL IMMEDIATELY INFORM CONTRACTING OFFICER OF ANY
ACTIVE OR INACTIVE UTILITIES FOUND DURING THE CONSTRUCTION WORK.
7. ITEMS NOT TO BE SALVAGED MUST BE PROMPTLY REMOVED FROM THE SITE BY
THE CONTRACTOR.
TREE REPLACEMENT
1. CONTRACTOR SHALL REMOVE EXISTING CEDAR TREE AND REPLACE WITH A
NURSERY-GROWN CEDAR TREE OF SIMILAR SPECIES.
2. REPLACEMENT TREE SHALL MEET THE FOLLOWING MINIMUM REQUIREMENTS:
12–14 FT HEIGHT
3-INCH MINIMUM CALIPER (MEASURED 6 INCHES ABOVE GRADE)
BALLED AND BURLAPPED (B&B) WITH MINIMUM 36-INCH ROOT BALL
3. SAPLINGS, WHIPS, OR CONTAINER-GROWN STOCK ARE NOT PERMITTED. TREE
SHALL BE WELL-FORMED, FREE OF DEFECTS, AND MEET ANSI Z60.1.
4. INSTALL PER INDUSTRY STANDARDS WITH ROOT FLARE AT OR ABOVE FINISHED
GRADE. PROVIDE MULCH AND WATERING AT TIME OF INSTALLATION.
5. TREE SHALL BE WARRANTED FOR 1 YEAR. ANY TREE THAT FAILS DURING THE
WARRANTY PERIOD SHALL BE REPLACED WITH A TREE MEETING THESE
REQUIREMENTS.
6. CONTRACTOR SHALL SUBMIT TREE FOR APPROVAL PRIOR TO INSTALLATION.
EXCAVATION, BACKFILLING AND COMPACTION
1. THE SITE MUST BE EXCAVATED, BACKFILLED, COMPACTED AND GRADED TO THE
ELEVATIONS AND LIMITS SHOWN IN THE DRAWING AND AS NEEDED TO MEET THE
REQUIREMENTS OF THE WORK.
2. SELECT BACKFILL SOILS MUST BE IMPORTED TO THE SITE TO MEET THE
SPECIFICATION FOR SELECT STRUCTURAL BACKFILL. EXCAVATED MATERIAL FROM
THE SITE, IF USED AS SELECT STRUCTURAL BACKFILL, MUST MEET THE PROJECT
SPECIFICATION FOR SELECT STRUCTURAL FILL.
3. MATERIALS TO BE USED AS SELECT BACKFILL BEHIND THE WALL MUST BE
GRANULAR AND HAVE A LIQUID LIMIT (LL) AND PLASTICITY INDEX (PI) OF LESS THAN
35 AND 15 RESPECTIVELY. THE SELECT BACKFILL MATERIAL MUST BE LIMITED TO
NO MORE THAN 30 PERCENT FINE PARTICLES PASSING THROUGH THE NO. 200
SIEVE.
4. STRUCTURAL BACKFILL MUST BE PLACED IN LOOSE LIFT NOT EXCEEDING 8 INCHES
IN THICKNESS AND SHOULD BE COMPACTED TO AT LEAST 95 PERCENT OF THE
MAXIMUM DRY DENSITY DETERMINED IN ACCORDANCE WITH ASTM D698
(STANDARD PROCTOR TEST). MOISTURE CONTENT OF THE FILL MATERIALS SHOULD
BE ±3 PERCENT OF THE OPTIMUM CONTENT PER ASTM D 698.
SYNTHETIC SHEET PILING AND ACCESSORIES
1. SYNTHETIC SHEET PILING MUST MEET THE FOLLOWING MINIMUM PROPERTIES.
2. SHEET PILING MUST BE FULL LENGTH SECTIONS OF THE DIMENSION INDICATED.
POLYVINYL CHLORIDE (PVC) SHEET PILE WALL MUST MEET THE FOLLOWING
MINIMUM MECHANICAL PROPERTIES
MINIMUM TENSILE STRENGTH: 6,500 PSI
MODULUS OF ELASTICITY: 400,000 PSI
ALLOWABLE BENDING STRENGTH: 3,200 PSI
IMPACT RESISTANCE: 1,500 IN.LB/IN
3. FIBER REINFORCED POLYMER (FRP) COMPOSITE SHEET PILE WALL MUST MEET THE
FOLLOWING MINIMUM PROPERTIES.
MINIMUM TENSILE STRENGTH: 75,000 PSI
MODULUS OF ELASTICITY: 2,200,000 PSI
ALLOWABLE BENDING STRENGTH: 10,000 PSI
4. PVC AND FRP SHEET PILE MUST BE UV-LIGHT ABSORBERS AND STABILIZERS AND
INCLUDE A MINIMUM 3 MIL POLYESTER OR NYLON VEIL.
5. SHEET PILE INTERLOCKS MUST BE FREE SLIDING AND MUST PROVIDE A SWING
ANGLE SUITABLE FOR THE INTENDED INSTALLATION AND MAINTAIN CONTINUOUS
INTERLOCKING WHEN INSTALLED.
6. CORNER CONNECTORS MUST BE HIGH IMPACT, CORROSION RESISTANCE PVC OR
MARINE GRADE ALUMINUM MATERIAL, AS RECOMMENDED BY SHEET PILE
MANUFACTURER. MANUFACTURER MUST RECOMMEND SPECIAL CORNER
CONNECTOR BETWEEN PVC AND FRP SHEET PILE CORNER.
STEEL TIE RODS AND ACCESSORIES
1. STEEL TIE ROD HEAD AND EXTENSION MUST BE ASTM A307 GRADE A OR ASTM
F1554, GRADE 36, WITH HOT DIP GALVANIZED AND POLYMER COATED.
2. TURNBUCKLE MUST BE ASTM F1145 TYPE 1-GRADE 1- CLASS B AND HOT DIP
GALVANIZED TO ASTM A153.
3. TIE ROD ACCESSORIES TO INCLUDE HOT DIP GALVANIZED HEX NUTS AND WASHERS
MUST BE ASTM A307.
4. ALL END PLATES MUST BE STAINLESS STEEL ASTM A240 TYPE 316. ALL FASTENERS,
THROUGH BOLTS AND LAG BOLTS MUST BE ASTM F593 TYPE 316.
RIPRAP STONES
1. RIPRAP STONE MUST BE CLOSED GRAINED, ANGULAR, HARD, SOUND, CLEAN AND
DURABLE LIMESTONE.
2. UNIT WEIGHT MUST BE MORE THAN 160 PCF PER ASTM D6473.
3. BULK SPECIFIC GRAVITY MUST BE 2.5 TO 2.9 BASED ON WATER HAVING A UNIT
WEIGHT OF 62.4 PCF PER ASTM C127.
4. ABSORPTION SHALL BE LESS THAN 2% PER ASTM C127.
5. BEDDING STONE MUST BE DURABLE QUALITY LIMESTONE WITH A BULK SPECIFIC
GRAVITY OF NOT LESS THAN 1.90 AND REASONABLY FREE FROM THIN, FLAT AND
ELONGATED PIECE. BEDDING STONE MUST BE FREE FROM ORGANIC MATTER AND
SOFT AND FRIABLE PARTICLES. GRADATION SHALL MEET FDOT SECTION 530
SPECIFICATION.
6. WOVEN GEOTEXTILE FILTER FABRIC MUST MEET FDOT SECTION 985 (TYPE D2)
TIMBERS AND LUMBERS
1. ALL WALE CORE MUST BE SOUND WOOD #2 MIXED SOUTHERN PINE, FREE FROM
DECAY AND DISEASE DAMAGE. THE SIZES SPECIFIED ARE NOMINAL SIZES.
2. ALL WALE CORE AND LUMBER MUST HAVE UV RESISTANT POLYMER SURFACE
MATERIAL. THE COLOR OF WALE MUST MATCH WITH HORIZONTAL FACING AND CAP
BOARDS TO BE INSTALLED ALONG THE WALL.
3. TREATING PRACTICES AND SAMPLING, INSPECTION AND TEST PROCEDURES MUST
CONFORM TO THE REQUIREMENT OF ASTM D 1760.
4. SALVAGED LUMBERS MUST BE DELIVERED CLEAN, DENAILED AND FREE OF PAINT,
FINISH MATERIAL AND OTHER CONTAMINATION.
5. BORON BASED PRESERVATIVE CONFORMING TO AWPA P18, SODIUM SILICATE
WOOD MINERALIZATION PROCESS, OR AMMONIACAL COPPER QUATERNARY
COMPOUND MUST BE USED TO TREAT HORIZONTAL FACING AND CAP WOOD
BOARDS.
GENERAL NOTES
02G0.1
BHADRA
KARTHI
POFF
TIMUCUAN ECOLOGICAL & HISTORICAL PRESERVE
TITLE OF SHEET DRAWING NO.
PMIS
NO. SHEET
OF
A/E FIRM
PRIME/CIVIL/STRUCT:
191524
SUB SHEET NO.DESIGNED:
CADD:
TECH. REVIEW:
DATE:
AECOM
SAVANNAH, GA
335507
THIS ITEM HAS BEEN DIGITALLY SIGNED
AND SEALED BY ANIRBAN BHADRA
PROFESSIONAL ENGINEER, STATE OF
FLORIDA, LICENSE NO. 98875 ON THE
DATE INDICATED HERE. PRINTED COPY
OF THIS DOCUMENT ARE NOT CONSIDERED
SIGNED & SEALED. THE SIGNATURE
MUST BE VERIFIED ON ANY ELECTRONIC
COPIES.
04/01/2026
SHEET PILE
TYPE
DEPTH
(IN)
THICKNESS
(IN)
ALLOWABLE
MOMENT
(FT-LBS/FT)
SECTION
MODULUS
(IN3/FT)
MOMENT
OF INERTIA
(IN4/FT)
PVC 10 0.48 8,480 31.80 159
FRP 17 0.54 48,750 58.50 497
ABBREVIATIONS LIST
A/E OR A&E - ARCHITECT/ENGINEER
ACI - AMERICAN CONCRETE INSTITUTE
AISC - AMERICAN INSTITUTE OF STEEL CONSTRUCTION
AITC - AMERICAN INSTITUTE OF TIMBER CONSTRUCTION
AMEND - AMENDMENT
ANSI - AMERICAN NATIONAL STANDARDS INSTITUTE
ASCE - AMERICAN SOCIETY FOR CIVIL ENGINEERS
ASTM - AMERICAN SOCIETY FOR TESTING AND MATERIALS
CAD - COMPUTER AIDED DESIGN
CPT - CONE PENETRATION TEST
DSC - DENVER SERVICE CENTER
ELEV / EL - ELEVATION
FDOT - FLORIDA DEPARTMENT OF TRANSPORTATION
FRP - FIBER REINFORCED POLYMER
IBC - INTERNATIONAL BUILDING CODE
IN - INCH/INCHES
ISO - INTERNATIONAL ORGANIZATION FOR STANDARDIZATION
LB - POUNDS
LL - LIQUID LIMIT
MDD - MAXIMUM DRY DENSITY
MECH - MECHANICAL
MHHW - MEAN HIGHER HIGH WATER
MHW - MEAN HIGH WATER
MLLW - MEAN LOWER LOW WATER
MLW - MEAN LOW WATER
MPH - MILES PER HOUR
MOD - MODIFICATION
MIN - MINIMUM
MSL - MEAN SEA LEVEL
NAD - NORTH AMERICAN DATUM
NAVD - NORTH AMERICAN VERTICAL DATUM
NCS - NATIONAL CAD STANDARD
NOAA - NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION
NPS - NATIONAL PARK SERVICES
O.C. - ON CENTER
OSHA - OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION
PCI - PRESTRESSED CONCRETE INSTITUTE
PCF - POUNDS PER CUBIC FOOT
PDF - PORTABLE DOCUMENT FORMAT
PI - PLASTICITY INDEX
PMIS - PROJECT MANAGEMENT INFORMATION SYSTEM
PMIS NO - PROJECT PMIS NUMBER
PSF - POUNDS PER SQUARE FOOT
PSI - POUND PER SQUARE INCH
PVC - POLYVINYL CHLORIDE
RCA - RECYCLED CONCRETE AGGREGATE
SPT - STANDARD PROCTOR TEST
STRUC - STRUCTURAL
TCS - TAPE COATING SYSTEM
TYP - TYPICAL
UFC - UNIFIED FACILITIES CRITERIA
U.S. - UNITED STATES
USACE - U.S. ARMY CORPS OF ENGINEERS
UV - ULTRAVIOLET
V - VERSION
V.I.F - VERIFY IN FIELD
V6 - VERSION 6
WL - WORK LIMIT
LEGEND AND
ABBREVIATIONS
03G0.2
BHADRA
KARTHI
POFF
TIMUCUAN ECOLOGICAL & HISTORICAL PRESERVE
TITLE OF SHEET DRAWING NO.
PMIS
NO. SHEET
OF
A/E FIRM
PRIME/CIVIL/STRUCT:
191524
SUB SHEET NO.DESIGNED:
CADD:
TECH. REVIEW:
DATE:
AECOM
SAVANNAH, GA
335507
THIS ITEM HAS BEEN DIGITALLY SIGNED
AND SEALED BY ANIRBAN BHADRA
PROFESSIONAL ENGINEER, STATE OF
FLORIDA, LICENSE NO. 98875 ON THE
DATE INDICATED HERE. PRINTED COPY
OF THIS DOCUMENT ARE NOT CONSIDERED
SIGNED & SEALED. THE SIGNATURE
MUST BE VERIFIED ON ANY ELECTRONIC
COPIES.
04/01/2026
MASTER LEGEND
WORK LIMIT
0 EXISTING MAJOR CONTOUR
16 EXISTING MINOR CONTOUR
PROPOSED MAJOR CONTOUR
PROPOSED MINOR CONTOUR
GRADING LIMITS
STONE RIPRAP
IMPORTED BACKFILL
RUBBER TRAIL
EXISTING SHEET PILE
PROPOSED SHEET PILE
EXISTING TREE
DEMOLITION
LIMIT FOR BACKFILLING
TB TOP OF BANK
TS TOP OF SLOPE
WOODEN FENCE
ACCESS ROUTE
DIRECTIONAL ARROWS
S3.1
A
DETAIL NUMBER OR
SECTION LETTER
INDICATES DIRECTION
OF SECTION
SHEET SHOWING SECTION
OR DETAIL
DETAIL
SCALE
A
SHT
DETAIL NUMBER OR
SECTION LETTER
DESCRIPTION
REFERENCE SHEET
WHERE SECTION OR
DETAIL IS TAKEN
-10
-5
-14
-14
-14
-13 -12
-11
-9 -8
-7
-6
-4
-3
-2
-1
12346
-15
-10
-5
-1
-14
-13 -12 -11
-9 -8 -7 -6
-4
-3
-2
-1
12346
-10
-5
-13-1
-12
-11
-9 -8
-7 -6
-4
-3
-2
-1
-10
-5
9 9
WL-1
WL-2
WL-3 WL-4
WL-5
WL-6
WL-7
WL-8
WL-9
WL-12
WL-13
WL-14
WL-17
WL-10
WL-11
WL-16
WL-15
PHASE 3 CONSTRUCTIONPHASE 1 CONSTRUCTION PHASE 2 CONSTRUCTION
KEY NOTES
PVC SHEET PILE WALL WITH TIE RODS AND DEADMAN WALLS
FRP COMPOSITE CANTILEVER SHEET PILE WALL
IMPORTED SOIL BACKFILL
LIMESTONE ROCK RIPRAP
EXISTING PVC BULKHEAD WITH STEEL TIE ROD AND
CONCRETE DEADMAN ABANDONED IN PLACE
LEGEND
1 4
TIMUCUAN ECOLOGICAL & HISTORICAL PRESERVE
TITLE OF SHEET DRAWING NO.
PMIS
NO. SHEET
OF
A/E FIRM
PRIME/CIVIL/STRUCT:
191524
SUB SHEET NO.DESIGNED:
CADD:
TECH. REVIEW:
DATE:
AECOM
SAVANNAH, GA
335507
THIS ITEM HAS BEEN DIGITALLY SIGNED
AND SEALED BY ANIRBAN BHADRA
PROFESSIONAL ENGINEER, STATE OF
FLORIDA, LICENSE NO. 98875 ON THE
DATE INDICATED HERE. PRINTED COPY
OF THIS DOCUMENT ARE NOT CONSIDERED
SIGNED & SEALED. THE SIGNATURE
MUST BE VERIFIED ON ANY ELECTRONIC
COPIES.
OVERALL SITE AND
CONSTRUCTION
PHASING PLAN 04G1.1
BHADRA
KARTHI
POFF
04/01/2026
NOTES
1. PROJECT SCOPE OF WORK IS SHOWN IN BLACK COLOR. EXISTING
FEATURES TO REMAIN ARE SHOWN IN GRAY COLOR.
2. WORK PRESENTED ON THIS SHEET DESCRIBES GENERAL INTENT
ONLY. NOT ALL PROJECT WORKS AND FEATURES ARE SHOWN FOR
CLARITY ON THIS SHEET.
3. UPON COMPLETION OF WALL CONSTRUCTION, EXISTING RUBBER
TRAIL MUST BE REINSTALLED.
WORK LIMIT
RUBBER TRAIL
LIMIT FOR BACKFILLING 25 50
SCALE OF FEET
0 25
WORKING LIMIT TABLE
WORKING LIMIT #
WL-1
NORTHING
2220391.67
2220409.42
2220351.78
2220281.32
2220275.83
2220233.69
2220183.54
2220127.33
2220172.30
EASTING
517934.47
517972.83
518130.12
518316.63
518314.42
518419.22
518500.42
518639.61
518655.61
WL-2
WL-3
WL-4
WL-5
WL-6
WL-7
WL-8
WL-9
WORKING LIMIT TABLE
WORKING LIMIT # NORTHING
2220270.79
2220308.85
2220325.23
2220401.42
2220470.75
2220437.15
2220424.64
EASTING
518437.97
518343.32
518349.64
518148.00
517958.40
517946.24
517919.21
WL-11
WL-12
WL-13
WL-14
WL-15
WL-16
WL-17
2220221.08 518518.44WL-10
EXISTING TREES
-14
-14
-14
-13 -12 -11
-9 -8
-7
-6
-4
-3
-2
-1
12346
-15
-10
-5
-1
-14
-13 -12 -11
-9 -8 -7 -6
-4
-3
-2
-1
12346
-10
-5
-13-1
-13
-12
-11
-9 -8
-7 -6
-4
-3
-2
-1
-10
-5
TIMUCUAN ECOLOGICAL & HISTORICAL PRESERVE
TITLE OF SHEET DRAWING NO.
PMIS
NO. SHEET
OF
A/E FIRM
PRIME/CIVIL/STRUCT:
191524
SUB SHEET NO.DESIGNED:
CADD:
TECH. REVIEW:
DATE:
AECOM
SAVANNAH, GA
335507
THIS ITEM HAS BEEN DIGITALLY SIGNED
AND SEALED BY ANIRBAN BHADRA
PROFESSIONAL ENGINEER, STATE OF
FLORIDA, LICENSE NO. 98875 ON THE
DATE INDICATED HERE. PRINTED COPY
OF THIS DOCUMENT ARE NOT CONSIDERED
SIGNED & SEALED. THE SIGNATURE
MUST BE VERIFIED ON ANY ELECTRONIC
COPIES.
KEY PLAN
05G1.2
BHADRA
KARTHI
POFF
04/01/2026
PLAN 1 PLAN 2 PLAN 3
25 50
SCALE OF FEET
0 25
-12
-11
-9
-8
-7
-6
-4
-3
-2
-1
12346
EXISTING PVC
BULKHEAD
RETURN WALL
137'-0" 246'-0"
EXISTING PVC
BULKHEAD
EXISTING TIE
ROD, TYP EXISTING PRECAST
CONCRETE DEADMAN
1 2
X3.1
A
'-5
STRUCTURE TO BE
REMOVED BY PARK
EXISTING CEDAR TREE
TO BE REPLACED
KEY MAP
1 2 3
LEGEND
WORK LIMIT
0 EXISTING MAJOR CONTOUR
16 EXISTING MINOR CONTOUR
EXISTING SHEET PILE
EXISTING TREE
RUBBER TRAIL
DEMOLITION
NOTES
1. DEMOLITION WORK SHOWN IN BLACK COLOR. EXISTING
ITEMS TO REMAIN ARE SHOWN IN GRAY COLOR FOR
CLARITY.
2. SURVEY TEXT SHOWN IN GRAY COLOR FOR CLARITY
REGARDLESS WHETHER ITEM IS TO BE DEMOLISHED OR
NOT.
3. DEMOLITION AND REMOVAL WORK MUST NOT DAMAGE
EXISTING ITEMS TO REMAIN. THE CONTRACTOR MUST
PROMPTLY REPORT TO THE CONTRACTING OFFICER ALL
DAMAGES RESULTING FROM HIS OPERATION ALONG
WITH HIS REPAIR RECOMMENDATION FOR APPROVAL.
CONTRACTOR MUST REPAIR ALL DAMAGES RESULTING
FROM HIS OPERATION TO THE SATISFACTION OF THE
CONTRACTING OFFICER.
4. ITEMS IDENTIFIED AS TO BE DEMOLISHED OR REMOVED
AND DEBRIS MUST BECOME THE PROPERTY OF THE
CONTRACTOR AND BE DISPOSED OFFSITE. EXERCISE
CARE WHEN REMOVING ITEMS TO AVOID DAMAGING
ADJACENT REMAINING ITEMS.
5. THE CONTRACTOR MUST FOLLOW CONSTRUCTION
SEQUENCE IN SHEETS S3.1 AND S3.2 PRIOR TO START
DEMOLITION.
6. THE CONTRACTOR MUST PROTECT THE TREES AND
STRUCTURES TO BE REMAIN IN PLACE DURING THE
DEMOLITION AND THROUGHOUT THE CONSTRUCTION.
7. THE CONTRACTOR MUST REINSTALL THE RUBBER TRAIL
AFTER COMPLETION OF THE CONSTRUCTION.
TIMUCUAN ECOLOGICAL & HISTORICAL PRESERVE
TITLE OF SHEET DRAWING NO.
PMIS
NO. SHEET
OF
A/E FIRM
PRIME/CIVIL/STRUCT:
191524
SUB SHEET NO.DESIGNED:
CADD:
TECH. REVIEW:
DATE:
AECOM
SAVANNAH, GA
335507
THIS ITEM HAS BEEN DIGITALLY SIGNED
AND SEALED BY ANIRBAN BHADRA
PROFESSIONAL ENGINEER, STATE OF
FLORIDA, LICENSE NO. 98875 ON THE
DATE INDICATED HERE. PRINTED COPY
OF THIS DOCUMENT ARE NOT CONSIDERED
SIGNED & SEALED. THE SIGNATURE
MUST BE VERIFIED ON ANY ELECTRONIC
COPIES.
DEMOLITION PLAN 1
06X1.1
BHADRA
KARTHI
POFF
04/01/2026
DEMOLITION NOTES
DISPOSE 2"x12" TIMBER SHEET PILE TOP WITH LAG BOLTS.
SALVAGE 2"x6" HORIZONTAL FACING TIMBERS ABOVE SPLASHING
ZONE TO BE RE-INSTALLED AT NEW WALL FACE. DISPOSE
HORIZONTAL FACING TIMBERS BELOW SPLASH ZONE.
CUT AND DISPOSE EXISTING TIE RODS.
SE
E
M
AT
C H
LI
N
E
SH
EE
T
X1 .2
10 20
0 10
-12
-11
-9
-8
-7
-6
-4
-3
-2
-1
12346
EXISTING PVC
BULKHEAD
EXISTING TIE
ROD, TYP
EXISTING PRECAST
CONCRETE DEADMAN
EXISTING PVC BULKHEAD
RETURN WALL
246'-0"
1 2
X3.1
A
'-6
KEY MAP
1 2 3
LEGEND
WORK LIMIT
0 EXISTING MAJOR CONTOUR
16 EXISTING MINOR CONTOUR
TB TOP OF BANK
EXISTING SHEET PILE
EXISTING TREE
DEMOLITION
NOTES
1. DEMOLITION WORK SHOWN IN BLACK COLOR. EXISTING
ITEMS TO REMAIN ARE SHOWN IN GRAY COLOR FOR
CLARITY.
2. SURVEY TEXT SHOWN IN GRAY COLOR FOR CLARITY
REGARDLESS WHETHER ITEM IS TO BE DEMOLISHED OR
NOT.
3. DEMOLITION AND REMOVAL WORK MUST NOT DAMAGE
EXISTING ITEMS TO REMAIN. THE CONTRACTOR MUST
PROMPTLY REPORT TO THE CONTRACTING OFFICER ALL
DAMAGES RESULTING FROM HIS OPERATION ALONG
WITH HIS REPAIR RECOMMENDATION FOR APPROVAL.
CONTRACTOR MUST REPAIR ALL DAMAGES RESULTING
FROM HIS OPERATION TO THE SATISFACTION OF THE
CONTRACTING OFFICER.
4. ITEMS IDENTIFIED AS TO BE DEMOLISHED OR REMOVED
AND DEBRIS MUST BECOME THE PROPERTY OF THE
CONTRACTOR AND BE DISPOSED OFFSITE. EXERCISE
CARE WHEN REMOVING ITEMS TO AVOID DAMAGING
ADJACENT REMAINING ITEMS.
5. CLEARING AND GRUBBING SHALL BE LIMITED TO ONLY
THOSE AREAS NECESSARY FOR INSTALLATION OF THE
SHEET PILE WALL EXTENSION AND ASSOCIATED
WORK. ALL OTHER VEGETATION AND EXISTING
FEATURES SHALL REMAIN UNDISTURBED.
6. THE CONTRACTOR MUST FOLLOW CONSTRUCTION
SEQUENCE IN SHEETS S3.1 AND S3.2 PRIOR TO START
DEMOLITION.
7. THE CONTRACTOR MUST PROTECT THE TREES AND
STRUCTURES TO BE REMAIN IN PLACE DURING THE
DEMOLITION AND THROUGHOUT THE CONSTRUCTION.
DEMOLITION PLAN 2
07X1.2
BHADRA
KARTHI
POFF
TIMUCUAN ECOLOGICAL & HISTORICAL PRESERVE
TITLE OF SHEET DRAWING NO.
PMIS
NO. SHEET
OF
A/E FIRM
PRIME/CIVIL/STRUCT:
191524
SUB SHEET NO.DESIGNED:
CADD:
TECH. REVIEW:
DATE:
AECOM
SAVANNAH, GA
335507
THIS ITEM HAS BEEN DIGITALLY SIGNED
AND SEALED BY ANIRBAN BHADRA
PROFESSIONAL ENGINEER, STATE OF
FLORIDA, LICENSE NO. 98875 ON THE
DATE INDICATED HERE. PRINTED COPY
OF THIS DOCUMENT ARE NOT CONSIDERED
SIGNED & SEALED. THE SIGNATURE
MUST BE VERIFIED ON ANY ELECTRONIC
COPIES.
04/01/2026
SE
E
M
AT
C H
LI
N
E
SH
EE
T
X1 .3
SE
E
M
AT
C H
LI
N
E
SH
EE
T
X1 .1
10 20
SCALE OF FEET
0 10DEMOLITION NOTES
DISPOSE 2"x12" TIMBER SHEET PILE TOP WITH LAG BOLTS.
SALVAGE 2"x6" HORIZONTAL FACING TIMBERS ABOVE SPLASHING
ZONE TO BE RE-INSTALLED AT NEW WALL FACE. DISPOSE
HORIZONTAL FACING TIMBERS BELOW SPLASH ZONE.
CUT AND DISPOSE EXISTING TIE RODS.
-11
-9
-8
-7
-6
-4
-3
-2
-1
-10
-5
KEY MAP
1 2 3
NOTES
1. DEMOLITION WORK SHOWN IN BLACK COLOR. EXISTING
ITEMS TO REMAIN ARE SHOWN IN GRAY COLOR FOR
CLARITY.
2. SURVEY TEXT SHOWN IN GRAY COLOR FOR CLARITY
REGARDLESS WHETHER ITEM IS TO BE DEMOLISHED OR
NOT.
3. DEMOLITION AND REMOVAL WORK MUST NOT DAMAGE
EXISTING ITEMS TO REMAIN. THE CONTRACTOR MUST
PROMPTLY REPORT TO THE CONTRACTING OFFICER ALL
DAMAGES RESULTING FROM HIS OPERATION ALONG WITH
HIS REPAIR RECOMMENDATION FOR APPROVAL.
CONTRACTOR MUST REPAIR ALL DAMAGES RESULTING
FROM HIS OPERATION TO THE SATISFACTION OF THE
CONTRACTING OFFICER.
4. ITEMS IDENTIFIED AS TO BE DEMOLISHED OR REMOVED
AND DEBRIS MUST BECOME THE PROPERTY OF THE
CONTRACTOR AND BE DISPOSED OFFSITE. EXERCISE
CARE WHEN REMOVING ITEMS TO AVOID DAMAGING
ADJACENT REMAINING ITEMS.
5. CLEARING AND GRUBBING SHALL BE LIMITED TO ONLY
THOSE AREAS NECESSARY FOR INSTALLATION OF THE
SHEET PILE WALL EXTENSION AND ASSOCIATED WORK.
ALL OTHER VEGETATION AND EXISTING FEATURES
SHALL REMAIN UNDISTURBED.
6. THE CONTRACTOR MUST PROTECT THE TREES AND
STRUCTURES TO BE REMAIN IN PLACE DURING THE
DEMOLITION AND THROUGHOUT THE CONSTRUCTION.
LEGEND
WORK LIMIT
0 EXISTING MAJOR CONTOUR
16 EXISTING MINOR CONTOUR
TB TOP OF BANK
TS TOP OF SLOPE
WOOD FENCE
EXISTING TREE
DEMOLITION PLAN 3
08X1.3
BHADRA
KARTHI
POFF
TIMUCUAN ECOLOGICAL & HISTORICAL PRESERVE
TITLE OF SHEET DRAWING NO.
PMIS
NO. SHEET
OF
A/E FIRM
PRIME/CIVIL/STRUCT:
191524
SUB SHEET NO.DESIGNED:
CADD:
TECH. REVIEW:
DATE:
AECOM
SAVANNAH, GA
335507
THIS ITEM HAS BEEN DIGITALLY SIGNED
AND SEALED BY ANIRBAN BHADRA
PROFESSIONAL ENGINEER, STATE OF
FLORIDA, LICENSE NO. 98875 ON THE
DATE INDICATED HERE. PRINTED COPY
OF THIS DOCUMENT ARE NOT CONSIDERED
SIGNED & SEALED. THE SIGNATURE
MUST BE VERIFIED ON ANY ELECTRONIC
COPIES.
04/01/2026
SE
E
M
AT
C H
LI
N
E
SH
EE
T
X1 .2
10 20
SCALE OF FEET
0 10DEMOLITION NOTES
DEMOLISH AND DISPOSE EXISTING WOOD FENCE1
+/- 30'-00"
EXISTING PRECAST 2"x2"x8"
CONCRETE DEADMAN TO
REMAIN IN PLACE
EXISTING FILL
ORIGINAL GRADE ELEV (+) 2.00
3/4" TURNBUCKLE
EXISTING PVC SHEET PILE
TO REMAIN IN PLACE
EXIST TIE RODS IN PVC SLEEVED
TO REMAIN IN PLACE EXCEPT
FOR SOME LOCATIONS SHOWN
IN PLANS (X1.1 AND X1.2)
REMOVE AND SALVAGE 2"x6" HORIZONTAL
FACING BOARD ABOVE SPLASH ZONE LAG
BOLTED TO EXISTING PVC SHEET PILE.
EXISTING 2"x12" SHEET PILE TIMBER
CAP, LAG BOLTED TO TOP OF WALES
TO BE REMOVED AND DISPOSED
APPROXIMATE EXISTING
GRADE
(+) 1.94 (MHW ELEVATION)
(+) 7.00 (EXISTING WALL TOP ELEVATION)
(-) 4.00 (ELEVATION)
VARIES
EXISTING 4"x8" TIMBER
WALES TO BE REMOVED
AND DISPOSED
APPROXIMATE EXISTING
GRADE
17'-0"
CUT, REMOVE AND DISPOSE
EXISTING TIE ROD INCLUDING
TURNBUCKLE AND PVC SLEEVES
REMOVE AND DISPOSE 2"x6" HORIZONTAL
FACING BOARD AT SPLASH ZONE.
TYPICAL SECTION EXISTING PVC SHEET PILE
SCALE: 1" = 2'
A
X1.1 AND X1.2
TIMUCUAN ECOLOGICAL & HISTORICAL PRESERVE
TITLE OF SHEET DRAWING NO.
PMIS
NO. SHEET
OF
A/E FIRM
PRIME/CIVIL/STRUCT:
191524
SUB SHEET NO.DESIGNED:
CADD:
TECH. REVIEW:
DATE:
AECOM
SAVANNAH, GA
335507
THIS ITEM HAS BEEN DIGITALLY SIGNED
AND SEALED BY ANIRBAN BHADRA
PROFESSIONAL ENGINEER, STATE OF
FLORIDA, LICENSE NO. 98875 ON THE
DATE INDICATED HERE. PRINTED COPY
OF THIS DOCUMENT ARE NOT CONSIDERED
SIGNED & SEALED. THE SIGNATURE
MUST BE VERIFIED ON ANY ELECTRONIC
COPIES.
DEMOLITION SECTION
09X3.1
BHADRA
KARTHI
POFF
04/01/2026
NOTES
1. EXISTING BULKHEAD INFORMATION SHOWN
BASED ON THE "RETAINING WALL
INSTALLATION" DRAWING BY NATIONAL
PARK SERVICES DATED JUNE 07, 1999.
2. LOCATION OF SUBSURFACE STRUCTURAL
ELEMENT IS APPROXIMATE. ALL DIMENSION
SHALL BE FIELD VERIFIED AND
COORDINATED WITH CONSTRUCTION
ACTIVITIES. THE CONTRACTOR SHALL
NOTIFY CONTRACTING OFFICER OF ANY
DISCREPANCIES.
3. SALVAGED HORIZONTAL FACING BOARDS
ABOVE SPLASH ZONE MUST BE REUSED
FOR INSTALLING NEW WALL FACIA. THE
CONTRACTOR SHALL TAKE NECESSARY
CARE WHILE REMOVING THOSE BOARDS
WITH NO OR MINIMAL DAMAGE.
4. THE CONTRACTOR MUST FOLLOW
CONSTRUCTION SEQUENCE IN SHEETS S3.1
AND S3.2 PRIOR TO START DEMOLITION.
LEGEND
REMOVE AND DISPOSE OFFSITE
REMOVE AND SALVAGE
2 4
0 2
-12
-11
-9
-8
-7
-6
-4
-3
-2
-1
12346
12'-0" 8'-0" 12'-0" 10'-0"
TYP
EXISTING PVC
BULKHEAD
RETURN WALL
12'-0"8'-0" 6'-0"
EXISTING PRECAST
CONCRETE DEADMAN (TYP.)
4'-0"
137'-0" 246'-0"
2'-8"
'-5
9' -8
'-0
'-0
(T
YP
30'-0" EXISTING PARK
FURNITURE
EXISTING TIE
ROD (TYP.)
EXISTING PVC
BULKHEAD
KEY MAP
1 2 3
LEGEND
WORK LIMIT
0 EXISTING MAJOR CONTOUR
16 EXISTING MINOR CONTOUR
EXISTING SHEET PILE
EXISTING TREE
RUBBER TRAIL
NOTES
1. ELEMENTS IN BLACK ON THE SHEET SERIES REPRESENT
CONDITION SURVEYED. ELEMENTS SHOWN IN GRAY
INDICATE OTHER EXISTING CONDITION, INCLUDED FOR
VISUAL CLARITY.
2. SURVEY CONTOURS AND TEXTS ARE SHOWN IN GRAY
COLOR FOR CLARITY.
3. LOCATION OF SUBSURFACE STRUCTURAL ELEMENTS
ARE APPROXIMATE. ALL DIMENSION SHALL BE FIELD
VERIFIED AND COORDINATED WITH CONSTRUCTION
ACTIVITIES. THE CONTRACTOR SHALL NOTIFY
CONTRACTING OFFICER OF ANY DISCREPANCIES.
4. EXISTING BULKHEAD INFORMATION SHOWN BASED ON
THE "RETAINING WALL INSTALLATION" DRAWING BY
NATIONAL PARK SERVICES DATED JUNE 07, 1999.
TIMUCUAN ECOLOGICAL & HISTORICAL PRESERVE
TITLE OF SHEET DRAWING NO.
PMIS
NO. SHEET
OF
A/E FIRM
PRIME/CIVIL/STRUCT:
191524
SUB SHEET NO.DESIGNED:
CADD:
TECH. REVIEW:
DATE:
AECOM
SAVANNAH, GA
335507
THIS ITEM HAS BEEN DIGITALLY SIGNED
AND SEALED BY ANIRBAN BHADRA
PROFESSIONAL ENGINEER, STATE OF
FLORIDA, LICENSE NO. 98875 ON THE
DATE INDICATED HERE. PRINTED COPY
OF THIS DOCUMENT ARE NOT CONSIDERED
SIGNED & SEALED. THE SIGNATURE
MUST BE VERIFIED ON ANY ELECTRONIC
COPIES.
EXISTING CONDITION
PLAN 1
10C1.1
POFF
KARTHI
BHADRA
04/01/2026
SE
E
M
AT
C H
LI
N
E
SH
EE
T
C 1.
10 20
-12
-11
-9
-8
-7
-6
-4
-3
-2
-1
12346
EXISTING PVC
BULKHEAD
EXISTING TIE
ROD (TYP.)
EXISTING PRECAST
CONCRETE DEADMAN (TYP.)
EXISTING PVC BULKHEAD
RETURN WALL
246'-0"
'-0
(T
YP
) 30'-0"
'-6
10'-0"
(TYP)
6'-0" 1'-7" 8'-0"12'-0"
9' -8
KEY MAP
1 2 3
LEGEND
WORK LIMIT
0 EXISTING MAJOR CONTOUR
16 EXISTING MINOR CONTOUR
TB TOP OF BANK
EXISTING SHEET PILE
EXISTING TREE
NOTES
1. ELEMENTS IN BLACK ON THE SHEET SERIES REPRESENT
CONDITION SURVEYED. ELEMENTS SHOWN IN GRAY
INDICATE OTHER EXISTING CONDITION, INCLUDED FOR
VISUAL CLARITY.
2. SURVEY CONTOURS AND TEXTS ARE SHOWN IN GRAY
COLOR FOR CLARITY.
3. LOCATION OF SUBSURFACE STRUCTURAL ELEMENTS
ARE APPROXIMATE. ALL DIMENSION SHALL BE FIELD
VERIFIED AND COORDINATED WITH CONSTRUCTION
ACTIVITIES. THE CONTRACTOR SHALL NOTIFY
CONTRACTING OFFICER OF ANY DISCREPANCIES.
4. EXISTING BULKHEAD INFORMATION SHOWN BASED ON
THE "RETAINING WALL INSTALLATION" DRAWING BY
NATIONAL PARK SERVICES DATED JUNE 07, 1999.
EXISTING CONDITION
PLAN 2
11C1.2
POFF
KARTHI
BHADRA
TIMUCUAN ECOLOGICAL & HISTORICAL PRESERVE
TITLE OF SHEET DRAWING NO.
PMIS
NO. SHEET
OF
A/E FIRM
PRIME/CIVIL/STRUCT:
191524
SUB SHEET NO.DESIGNED:
CADD:
TECH. REVIEW:
DATE:
AECOM
SAVANNAH, GA
335507
THIS ITEM HAS BEEN DIGITALLY SIGNED
AND SEALED BY ANIRBAN BHADRA
PROFESSIONAL ENGINEER, STATE OF
FLORIDA, LICENSE NO. 98875 ON THE
DATE INDICATED HERE. PRINTED COPY
OF THIS DOCUMENT ARE NOT CONSIDERED
SIGNED & SEALED. THE SIGNATURE
MUST BE VERIFIED ON ANY ELECTRONIC
COPIES.
04/01/2026
SE
E
M
AT
C H
LI
N
E
SH
EE
T
C 1.
SE
E
M
AT
C H
LI
N
E
SH
EE
T
C 1.
10 20
-11
-9
-8
-7
-6
-4
-3
-2
-1
-10
-5
KEY MAP
1 2 3
LEGEND
WORK LIMIT
0 EXISTING MAJOR CONTOUR
16 EXISTING MINOR CONTOUR
TB TOP OF BANK
TS TOP OF SLOPE
WOOD FENCE
EXISTING TREE
NOTES
1. ELEMENTS IN BLACK ON THE SHEET SERIES REPRESENT
CONDITION SURVEYED. ELEMENTS SHOWN IN GRAY
INDICATE OTHER EXISTING CONDITION, INCLUDED FOR
VISUAL CLARITY.
2. SURVEY CONTOURS AND TEXTS ARE SHOWN IN GRAY
COLOR FOR CLARITY.
EXISTING CONDITION
PLAN 3
12C1.3
POFF
KARTHI
BHADRA
04/01/2026
SE
E
M
AT
C H
LI
N
E
SH
EE
T
C 1.
10 20
SCALE OF FEET
0 10
TIMUCUAN ECOLOGICAL & HISTORICAL PRESERVE
TITLE OF SHEET DRAWING NO.
PMIS
NO. SHEET
OF
A/E FIRM
PRIME/CIVIL/STRUCT:
191524
SUB SHEET NO.DESIGNED:
CADD:
TECH. REVIEW:
DATE:
AECOM
SAVANNAH, GA
335507
THIS ITEM HAS BEEN DIGITALLY SIGNED
AND SEALED BY ANIRBAN BHADRA
PROFESSIONAL ENGINEER, STATE OF
FLORIDA, LICENSE NO. 98875 ON THE
DATE INDICATED HERE. PRINTED COPY
OF THIS DOCUMENT ARE NOT CONSIDERED
SIGNED & SEALED. THE SIGNATURE
MUST BE VERIFIED ON ANY ELECTRONIC
COPIES.
15' (MIN)
8" (MIN)
EXISTING GROUND NONWOVEN GEOTEXTILE
FABRIC
AGGREGATE BASE
MATERIAL (NOTE 3)
0'
-0
50'-0" 15'-0"
GTB2
0'
-0
50'-0"
GTB1
GTB3
GTB4
GTB5
GTB6
TIMUCUAN ECOLOGICAL & HISTORICAL PRESERVE
TITLE OF SHEET DRAWING NO.
PMIS
NO. SHEET
OF
A/E FIRM
PRIME/CIVIL/STRUCT:
191524
SUB SHEET NO.DESIGNED:
CADD:
TECH. REVIEW:
DATE:
AECOM
SAVANNAH, GA
335507
THIS ITEM HAS BEEN DIGITALLY SIGNED
AND SEALED BY ANIRBAN BHADRA
PROFESSIONAL ENGINEER, STATE OF
FLORIDA, LICENSE NO. 98875 ON THE
DATE INDICATED HERE. PRINTED COPY
OF THIS DOCUMENT ARE NOT CONSIDERED
SIGNED & SEALED. THE SIGNATURE
MUST BE VERIFIED ON ANY ELECTRONIC
COPIES.
CONTRACTOR SITE ACCESS
AND STAGING AREA
13C1.4
POFF
KARTHI
BHADRA
04/01/2026
NOTES
1. A TEMPORARY HAUL ROAD SHALL BE PROVIDED FOR CONSTRUCTION ACTIVITIES FOR THE DURATION
OF CONSTRUCTION.
2. A NONWOVEN GEOTEXTILE SEPARATOR SHALL BE INSTALLED BENEATH THE HAUL ROAD IN
ACCORDANCE WITH FDOT SECTION 985, TYPE IV, OR APPROVED EQUIVALENT.
3. AGGREGATE BASE MATERIAL SHALL CONSIST OF FDOT SECTION 911 BASE MATERIAL, INCLUDING
LIME ROCK BASE OR RECYCLED CONCRETE AGGREGATE (RCA), MEETING FDOT REQUIREMENTS.
4. THE TEMPORARY HAUL ROAD SHALL BE CONSTRUCTED AND MAINTAINED BY THE CONTRACTOR IN A
CONDITION SUITABLE FOR CONSTRUCTION ACCESS FOR THE DURATION OF THE WORK.
5. THE TEMPORARY HAUL ROAD SHALL INCLUDE PULL-OFF AREAS AS NECESSARY TO ACCOMMODATE
CONSTRUCTION ACCESS AND TRAFFIC.
6. UPON COMPLETION OF CONSTRUCTION, ALL HAUL ROAD AND LAYDOWN AREA MATERIALS SHALL BE
REMOVED AND DISPOSED OFFSITE. DISTURBED AREAS RESTORED TO EXISTING CONDITIONS.
7. TEMPORARY ACCESS ROAD WAY MUST BE CONSTRUCTED TO AVOID ANY DISTURBANCE TO EXISTING
TREES.
8. TEMPORARY EMBANKMENT OF THE ACCESS ROAD MUST MAINTAIN POSITIVE DRAINAGE AND AVOID
PONDING.
9. TEMPORARY ACCESS ROAD MUST BE STABILIZED AT THE ENTRANCE.
10. CONTRACTOR DELIVERIES SHALL BE LIMITED TO MONDAYS AND TUESDAYS. DELIVERIES ON OTHER DAYS SHALL ONLY BE DONE IF APPROVED BY PARK MANAGEMENT AND SHALL ONLY BE CONDUCTED
WHEN THE PARK IS CLOSED.
11. TREE PROTECTION SHALL BE PROVIDED IN ACCORDANCE WITH FDOT STANDARD FY 2026-27
STANDARD PLAN 110-100 FOR TREE PROTECTION AND PRESERVATION.
12. ALL GOPHER TORTOISE BURROWS WITHIN OR ADJACENT TO THE PROJECT AREA SHALL BE
PROTECTED. BURROWS SHALL NOT BE EXCAVATED, FILLED, OR OTHERWISE DISTURBED WITHOUT
PRIOR AUTHORIZATION AND PERMIT FROM THE FLORIDA FISH AND WILDLIFE CONSERVATION
COMMISSION (FWC). IF A BURROW IS ENCOUNTERED DURING CONSTRUCTION, WORK SHALL STOP IN
THE IMMEDIATE AREA AND THE CONTRACTING OFFICE SHALL BE NOTIFIED.
13. EXISTING ROAD TO DUMPSTER TO BE CLEAR FOR VEHICLE MOVEMENT ALL TIME DURING THE
CONSTRUCTION.
14. WOODEN POSTS AT THE ENTRANCE OF HAUL ROAD TO BE REMOVED, SALVAGED AND REINSTALL ON
COMPLETION OF CONSTRUCTION.
SECTION A
NOT TO SCALE
A C1.5
FORT GEORGE RIVER
FORT GEORGE RIVER
EXISTING WALL
PLANTER'S
HOUSE
VISITORS
CENTER
KITCHEN
HOUSE
BARN
TEMPORARY
ACCESS ROAD
C1.5
A
VISITOR PARKING
AREA
L ENGLE AVE
PA
LM
ET
TO
A
VE
LEGEND
STAGING / LAYDOWN AREA
CM/CONTRACTOR PARKING AND
TRAILER AREA
GOPHER TURTLE LOCATION
ACCESS ROUTE
DIRECTIONAL ARROWS
50 100
SCALE OF FEET
0 50
PRESERVE AND PROTECT
EXISTING CEDAR TREE
(SEE NOTE 11)
EXISTING ROAD
TO DUMPSTER
INSTALL FENCE TO BLOCK
ACCESS THROUGH THE TRAIL
DURING CONSTRUCTION
-14
-14
-14
-13 -12 -11
-9 -8
-7
-6
-4
-3
-2
-1
12346
-15
-10
-5
-1
-14
-13 -12 -11
-9 -8 -7 -6
-4
-3
-2
-1
12346
-10
-5
-12
-11
-9 -8
-7 -6
-4
-3
-2
-1
-5
ATS-04ATS-03
ATS-02
ATS-01 CPTU-01
CPTU-02
TIMUCUAN ECOLOGICAL & HISTORICAL PRESERVE
TITLE OF SHEET DRAWING NO.
PMIS
NO. SHEET
OF
A/E FIRM
PRIME/CIVIL/STRUCT:
191524
SUB SHEET NO.DESIGNED:
CADD:
TECH. REVIEW:
DATE:
AECOM
SAVANNAH, GA
335507
THIS ITEM HAS BEEN DIGITALLY SIGNED
AND SEALED BY ANIRBAN BHADRA
PROFESSIONAL ENGINEER, STATE OF
FLORIDA, LICENSE NO. 98875 ON THE
DATE INDICATED HERE. PRINTED COPY
OF THIS DOCUMENT ARE NOT CONSIDERED
SIGNED & SEALED. THE SIGNATURE
MUST BE VERIFIED ON ANY ELECTRONIC
COPIES.
SOIL BORING AND
BENCHMARK LOCATION
PLAN 14C1.5
POFF
KARTHI
BHADRA
04/01/2026
DENOTES SOIL BORING LOCATION
DENOTES CPT SOUNDING LOCATION
EXISTING SHEET PILE
WALL
NOTES
1. GEOTECHNICAL DATA COLLECTION LISTED
HEREIN WAS COLLECTED IN 04/2024. REFER TO
AECOM GEOTECHNICAL REPORT "GEOTECHNICAL
ENGINEERING REPORT" DATED APRIL 14TH 2025.
2. BORING AND CPT LOCATIONS ARE APPROXIMATE.
LEGEND
25 50
SCALE OF FEET
0 25
REFERENCE BENCHMARK
TEMPORARY BENCHMARK
REFERENCE BENCHMARK
FOUND BRASS DISK
STAMPED ”0186 A 1987”
ELEV=8.22’ (NAVD 1988)
EASTING : 517951.750
NORTHING : 2220403.920
REFERENCE BENCHMARK
FOUND BRASS DISK STAMPED
"FT GEORGE NO. 1 1977"
ELEV=9.32' (NAVD 1988)
EASTING : 518466.520
NORTHING : 2220212.190
TEMPORARY BENCHMARK
SET 5/8” IRON ROD WITH CAP
STAMPED ”SSMC TRAV PT”
ELEV=9.46’ (NAVD 1988)
TEMPORARY BENCHMARK
SET 5/8” IRON ROD WITH CAP
STAMPED ”SSMC TRAV PT”
ELEV=2.15’ (NAVD 1988)
TEMPORARY BENCHMARK
SET 5/8” IRON ROD WITH CAP
STAMPED ”SSMC TRAV PT”
ELEV=7.79’ (NAVD 1988)
-12
-11
-9 -8
-7
-6
-4
-3
-2
-1
12346
RIPRAP
(FRONT WALL)
SG750 PVC
SHEET PILE WALL
TOP OF WALL 8.5'
8.56
8.50 8.66 8.62
8.50
8.82 8.85 8.88 8.98 8.99 8.99 8.99 8.99 8.81
8.96
8.99 8.99 8.99 8.99 8.99 8.81
8.98 9.00
9.00 9.00 8.99
8.99 8.99 8.82
9.00 9.00 8.99 8.99 8.99 8.83
9.00 9.00 8.99 8.99 8.99 8.84
9.00
9.00 8.99 8.99
8.99 8.85
9.00
8.99 8.99 8.99 8.86
9.00 8.99 8.99 8.99 8.87
9.00
8.99 8.99 8.99
8.88
9.00
8.99 8.99 8.99 8.88
9.00 8.99
8.99 8.99 8.89
9.00 8.99 8.99 8.99 8.90
9.00
8.99 8.99 8.91
8.99 8.99
8.99 8.92
8.99 8.99 8.99 8.91
8.99 8.99 8.99 8.91
8.99 8.99
8.90
8.99 8.99 8.90
8.99 8.99 8.89
8.99 8.99 8.89
8.99 8.99 8.88
8.99 8.99 8.88
8.99 8.99 8.87
8.55
8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50
TIMUCUAN ECOLOGICAL & HISTORICAL PRESERVE
TITLE OF SHEET DRAWING NO.
PMIS
NO. SHEET
OF
A/E FIRM
PRIME/CIVIL/STRUCT:
191524
SUB SHEET NO.DESIGNED:
CADD:
TECH. REVIEW:
DATE:
AECOM
SAVANNAH, GA
335507
THIS ITEM HAS BEEN DIGITALLY SIGNED
AND SEALED BY ANIRBAN BHADRA
PROFESSIONAL ENGINEER, STATE OF
FLORIDA, LICENSE NO. 98875 ON THE
DATE INDICATED HERE. PRINTED COPY
OF THIS DOCUMENT ARE NOT CONSIDERED
SIGNED & SEALED. THE SIGNATURE
MUST BE VERIFIED ON ANY ELECTRONIC
COPIES.
KEY MAP
1 2 3 GRADING PLAN 1
15C1.6
POFF
04/01/2026
KARTHI
BHADRA
LEGEND
WORK LIMIT
PROPOSED MAJOR CONTOUR
PROPOSED MINOR CONTOUR
GRADING LIMITS
EXISTING MAJOR CONTOUR
EXISTING MINOR CONTOUR
STONE RIPRAP
PROPOSED SHEET PILE
EXISTING TREE
NOTES
1. SOD ALL DISTURBED AREAS NOT OTHERWISE
PAVED OR STABILIZED. SOD AND INSTALLATION
SHALL CONFORM TO TECHNICAL SPECIFICATION
SECTION 32 92 23. CONTRACTOR SHALL
MAINTAIN SOD UNTIL FINAL ACCEPTANCE.
SE
E
M
AT
C H
LI
N
E
SH
EE
T
C 1.
10 20
-12
-11
-9
-8
-7
-6
-4
-3
-2
-1
12346
RIPRAP
(FRONT WALL)
SG750 PVC
SHEET PILE WALL TOP OF WALL 8.5'
SCOUR PROTECTION
(STONE RIPRAP)
8.99
8.99
8.87
8.99
8.99
8.87
8.99
8.99
8.86
8.99
8.99
8.86
8.99
8.99
8.85
8.99
8.99
8.85
8.99
8.99
8.84
8.99
8.99
8.84
8.99
8.99
8.83
8.99
8.99
8.83
8.99
8.99
8.82
8.99
8.99
8.82
8.99
8.99
8.81
8.99
8.99
8.99
8.81
8.99
8.99
8.99
8.80
8.99
8.99
8.99
8.80
9.01 8.97 8.95 8.92 8.90 8.87 8.85 8.82 8.79 8.77 8.74
8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50
8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50
8.50
8.50
8.50
8.50
8.50
8.50 8.50 8.50 8.50 8.50 8.50 8.50
8.50 8.50 8.50
KEY MAP
1 2 3
TIMUCUAN ECOLOGICAL & HISTORICAL PRESERVE
TITLE OF SHEET DRAWING NO.
PMIS
NO. SHEET
OF
A/E FIRM
PRIME/CIVIL/STRUCT:
191524
SUB SHEET NO.DESIGNED:
CADD:
TECH. REVIEW:
DATE:
AECOM
SAVANNAH, GA
335507
THIS ITEM HAS BEEN DIGITALLY SIGNED
AND SEALED BY ANIRBAN BHADRA
PROFESSIONAL ENGINEER, STATE OF
FLORIDA, LICENSE NO. 98875 ON THE
DATE INDICATED HERE. PRINTED COPY
OF THIS DOCUMENT ARE NOT CONSIDERED
SIGNED & SEALED. THE SIGNATURE
MUST BE VERIFIED ON ANY ELECTRONIC
COPIES.
GRADING PLAN 2
16C1.7
POFF
KARTHI
BHADRA
04/01/2026
NOTES
1. SOD ALL DISTURBED AREAS NOT OTHERWISE
PAVED OR STABILIZED. SOD AND INSTALLATION
SHALL CONFORM TO TECHNICAL SPECIFICATION
SECTION 32 92 23. CONTRACTOR SHALL
MAINTAIN SOD UNTIL FINAL ACCEPTANCE.
LEGEND
WORK LIMIT
PROPOSED MAJOR CONTOUR
PROPOSED MINOR CONTOUR
GRADING LIMITS
EXISTING MAJOR CONTOUR
EXISTING MINOR CONTOUR
TOP OF BANK
STONE RIPRAP
PROPOSED SHEET PILE
EXISTING TREE
TB
SE
E
M
AT
C H
LI
N
E
SH
EE
T
C 1.
SE
E
M
AT
C H
LI
N
E
SH
EE
T
C 1.
10 20
-11
-9
-8
-7
-6
-4
-3
-2
-1
-10
-5
9 9
8.72
9.10
8.50
8.84
9.34
8.65
8.94 8.74
9.10
8.55
8.84
9.34
8.65
8.94 8.84 8.86 8.87 8.89 8.90 8.92 8.93 8.95 8.96 8.98 9.00
8.50
9.70
9.70
9.04
8.50
9.70
9.39
8.50
9.60
9.42
8.97
8.50
8.50
8.50
8.50
8.50
8.50
8.50
8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50
8.50
SCOUR PROTECTION
(STONE RIPRAP)
UC-95 FRP CANTILEVER
SHEET PILE WALL
RIPRAP (RETURN WALL)
TOP OF WALL 8.5'
UC-95 FRP SHEET PILE
RETURN WALL
KEY MAP
1 2 3 GRADING PLAN 3
17C1.8
POFF
KARTHI
BHADRA
TIMUCUAN ECOLOGICAL & HISTORICAL PRESERVE
TITLE OF SHEET DRAWING NO.
PMIS
NO. SHEET
OF
A/E FIRM
PRIME/CIVIL/STRUCT:
191524
SUB SHEET NO.DESIGNED:
CADD:
TECH. REVIEW:
DATE:
AECOM
SAVANNAH, GA
335507
THIS ITEM HAS BEEN DIGITALLY SIGNED
AND SEALED BY ANIRBAN BHADRA
PROFESSIONAL ENGINEER, STATE OF
FLORIDA, LICENSE NO. 98875 ON THE
DATE INDICATED HERE. PRINTED COPY
OF THIS DOCUMENT ARE NOT CONSIDERED
SIGNED & SEALED. THE SIGNATURE
MUST BE VERIFIED ON ANY ELECTRONIC
COPIES.
04/01/2026
NOTES
1. SOD ALL DISTURBED AREAS NOT OTHERWISE
PAVED OR STABILIZED. SOD AND INSTALLATION
SHALL CONFORM TO TECHNICAL SPECIFICATION
SECTION 32 92 23. CONTRACTOR SHALL
MAINTAIN SOD UNTIL FINAL ACCEPTANCE.
LEGEND
WORK LIMIT
PROPOSED MAJOR CONTOUR
PROPOSED MINOR CONTOUR
GRADING LIMITS
EXISTING MAJOR CONTOUR
EXISTING MINOR CONTOUR
TOP OF BANK
TOP OF SLOPE
STONE RIPRAP
PROPOSED SHEET PILE
EXISTING TREE
TB
TS
SE
E
M
AT
C H
LI
N
E
SH
EE
T
C 1.
10 20
SHEET PILE WALL
EXTENSION
5'-0"3'-0"
RIPRAP SCOUR PROTECTION
(6" TO 12" LIMESTONE ROCK) TYP
EXISTING RIVER
BED LEVEL
1'-6"
10'-0"2'-0"
1'-6"
SHEET PILE WALL
EXTENSION
WOVEN GEOTEXTILE
FILTER LAYER
EXISTING RIVER
BED LEVEL
RIPRAP SCOUR PROTECTION
(6" TO 12" LIMESTONE ROCK) TYP
0'-6"
BEDDING STONE
TYPICAL SPARTINA PLANTING AREA (SEE NOTE 1 & 2)
RIP RAP DETAILS
18C3.1KARTHI
BHADRA
TIMUCUAN ECOLOGICAL & HISTORICAL PRESERVE
TITLE OF SHEET DRAWING NO.
PMIS
NO. SHEET
OF
A/E FIRM
PRIME/CIVIL/STRUCT:
191524
SUB SHEET NO.DESIGNED:
CADD:
TECH. REVIEW:
DATE:
AECOM
SAVANNAH, GA
335507
THIS ITEM HAS BEEN DIGITALLY SIGNED
AND SEALED BY ANIRBAN BHADRA
PROFESSIONAL ENGINEER, STATE OF
FLORIDA, LICENSE NO. 98875 ON THE
DATE INDICATED HERE. PRINTED COPY
OF THIS DOCUMENT ARE NOT CONSIDERED
SIGNED & SEALED. THE SIGNATURE
MUST BE VERIFIED ON ANY ELECTRONIC
COPIES.
POFF
04/01/2026
TYPICAL HAND INSTALLED RIPRAP DETAILS - PVC SHEET PILE WALL SECTION IN FRONT OF EXISTING WALL
SCALE: 1" = 1'
C S3.1
TYPICAL RIPRAP DETAILS - SHEET PILE WALL EXTENSION
SCALE: 1" = 1'
D S3.2
1 2
SCALE OF FEET
0 1
NOTES
1. THE CONTRACTOR SHALL PLANT THE
SALTMEADOW CORDGRASS (SPARTINA PATENS) IN
THE AREA EXTENDING FROM THE NEWLY
INSTALLED EXTENSION WALL RIPRAP TOE OUT TO
+2 FEET NAVD88 CONTOUR LINE. SPACING FOR
SPARTINA PATENS SHALL BE 1 FEET ON CENTER
IN A STAGGERED (TRANGLE) DISTRIBUTION.
2. THE CONTRACTOR SHALL PLANT THE SMOOTH
CORDGRASS (SPARTINA ALTERNIFOLIA)
WATERWARD OF PLANTED SALTMEADOW
CORDGRASS (SPARTINA PATENS) BETWEEN +2
FEET NAVD88 CONTOUR LINE AND THE +1.95
NAVD88 MEAN HIGH WATER LINE. SPACING FOR
SPARTINA ALTERNIFOLIAOF SHALL BE 5 FEET ON
CENTER IN A STAGGERED (TRANGLE)
DISTRIBUTION.
TIMUCUAN ECOLOGICAL & HISTORICAL PRESERVE
TITLE OF SHEET DRAWING NO.
PMIS
NO. SHEET
OF
A/E FIRM
PRIME/CIVIL/STRUCT:
191524
SUB SHEET NO.DESIGNED:
CADD:
TECH. REVIEW:
DATE:
AECOM
SAVANNAH, GA
335507
THIS ITEM HAS BEEN DIGITALLY SIGNED
AND SEALED BY ANIRBAN BHADRA
PROFESSIONAL ENGINEER, STATE OF
FLORIDA, LICENSE NO. 98875 ON THE
DATE INDICATED HERE. PRINTED COPY
OF THIS DOCUMENT ARE NOT CONSIDERED
SIGNED & SEALED. THE SIGNATURE
MUST BE VERIFIED ON ANY ELECTRONIC
COPIES.
SOIL BORING LOGS 1
19C6.1
POFF
KARTHI
BHADRA
04/01/2026
NOTES
1. GEOTECHNICAL DATA COLLECTION LISTED HEREIN
WAS COLLECTED IN 04/2024. REFER TO AECOM
GEOTECHNICAL REPORT "GEOTECHNICAL
ENGINEERING REPORT" DATED APRIL 14TH 2025.
2. FOR BORING LOCATIONS SEE DRAWING C1.5.
TIMUCUAN ECOLOGICAL & HISTORICAL PRESERVE
TITLE OF SHEET DRAWING NO.
PMIS
NO. SHEET
OF
A/E FIRM
PRIME/CIVIL/STRUCT:
191524
SUB SHEET NO.DESIGNED:
CADD:
TECH. REVIEW:
DATE:
AECOM
SAVANNAH, GA
335507
THIS ITEM HAS BEEN DIGITALLY SIGNED
AND SEALED BY ANIRBAN BHADRA
PROFESSIONAL ENGINEER, STATE OF
FLORIDA, LICENSE NO. 98875 ON THE
DATE INDICATED HERE. PRINTED COPY
OF THIS DOCUMENT ARE NOT CONSIDERED
SIGNED & SEALED. THE SIGNATURE
MUST BE VERIFIED ON ANY ELECTRONIC
COPIES.
SOIL BORING LOGS 2
20C6.2
POFF
KARTHI
BHADRA
04/01/2026
NOTES
1. GEOTECHNICAL DATA COLLECTION LISTED HEREIN
WAS COLLECTED IN 04/2024. REFER TO AECOM
GEOTECHNICAL REPORT "GEOTECHNICAL
ENGINEERING REPORT" DATED APRIL 14TH 2025.
2. FOR BORING LOCATIONS SEE DRAWING C1.5.
-12
-11
-9
-8
-7
-6
-4
-3
-2
-1
12346
WEATHERABLE
RIGID VINYL (PVC)
SHEET PILE WALL
FACE OF EXISTING
SHEET PILE WALL
3/4" DIA TIE
ROD, TYP
RIPRAP
(FRONT WALL)
SEE NOTE 3 SEE NOTE 2
RIPRAP
WEATHERABLE RIGID
VINYL (PVC) SHEET
PILE (RETURN WALL)
S3.1
A
B S5.1
D S5.2
139'-6" 247'-6"
'-0
4'-2" 4'-6" 4'-0" 3'-6" 4'-6" 5'-0"
(TYP)
4'-0"
4'-6"
'-6
(T
YP
12'-9"
3' -6
WP-2
WP-3
WP-4
3'-6"
3' -6
EXISTING CEDER TREE TO BE
REPLACED WITH MINIMUM 10
YEARS OLD SAME SPECIES TREE
'-0
'-6
WP-1
H S5.2
A S5.1
KEY MAP
1 2 3
LEGEND
WORK LIMIT
0 EXISTING MAJOR CONTOUR
16 EXISTING MINOR CONTOUR
STONE RIPRAP
EXISTING SHEET PILE
PROPOSED SHEET PILE
EXISTING TREE
NOTES
1. PROPOSED STRUCTURAL ELEMENTS ARE
SHOWN IN BLACK ON THIS SHEET SERIES.
ELEMENTS SHOWN IN GRAY INDICATE EXISTING
CONDITION.
2. SHEET PILE WALL PLAN TYPE I - FOR DETAIL
REFER SHEET S5.1.
3. SHEET PILE WALL PLAN TYPE II - FOR DETAIL
REFER SHEET S5.1.
4. THE LOCATION OF SUBSURFACE STRUCTURAL
ELEMENTS IS APPROXIMATE. ALL DEMOLITION
SHALL BE FIELD VERIFIED. CONTRACTOR SHALL
NOTIFY CONTRACTING OFFICER IN WRITING OF
ANY DISCREPANCIES IN PLAN.
5. THE WORKING POINTS (WP) ARE BASED ON
TOPOGRAPHIC SURVEY. THE CONTRACTOR
MUST SITE VERIFY ALL POINTS. ANY
DISCREPANCIES MUST BE REPORTED TO THE
CONTRACTING OFFICER.
6. THE CONTRACTOR MUST NOT REMOVE ANY
TREE FOR CONSTRUCTING DEADMAN WALL OR
INSTALLING TIE ROD. THE CONTRACTOR MUST
INFORM THE CONTRACTING OFFICER IF ANY
TREE IS PRESENT AT THE DEADMAN OR TIE ROD
LOCATION.
7. ALL PALM TREES AT THE EXCAVATION AREA
MUST BE PROTECTED DURING THE
CONSTRUCTION PERIOD IN ACCORDANCE WITH
FDOT FY 2026-27 STANDARD PLAN 110-100, TREE
PROTECTION AND PRESERVATION.
GENERAL LAYOUT PLAN 1
21S1.1
BHADRA
04/01/2026
KARTHI
POFF
WORKING POINT TABLE
WORKING
POINT # NORTHING EASTING
WP-1 2220416.95 517939.29
WP-2 2220425.85 517958.51
WP-3 2220450.97 517967.73
WP-4 2220403.63 518098.53
SE
E
M
AT
C H
LI
N
E
SH
EE
T
S1 .2
TIMUCUAN ECOLOGICAL & HISTORICAL PRESERVE
TITLE OF SHEET DRAWING NO.
PMIS
NO. SHEET
OF
A/E FIRM
PRIME/CIVIL/STRUCT:
191524
SUB SHEET NO.DESIGNED:
CADD:
TECH. REVIEW:
DATE:
AECOM
SAVANNAH, GA
335507
THIS ITEM HAS BEEN DIGITALLY SIGNED
AND SEALED BY ANIRBAN BHADRA
PROFESSIONAL ENGINEER, STATE OF
FLORIDA, LICENSE NO. 98875 ON THE
DATE INDICATED HERE. PRINTED COPY
OF THIS DOCUMENT ARE NOT CONSIDERED
SIGNED & SEALED. THE SIGNATURE
MUST BE VERIFIED ON ANY ELECTRONIC
COPIES.
10 20
-12
-11
-9
-8
-7
-6
-4
-3
-2
-1
12346
SCOUR PROTECTION
(STONE RIPRAP)
3/4" DIA TIE
ROD, TYP SEE NOTE 3
SEE NOTE 2
RIPRAP
FACE OF EXISTING
SHEET PILE WALL
WEATHERABLE
RIGID VINYL (PVC)
SHEET PILE WALL
S3.1
A
S3.2
B
E S5.2
C S5.1
2'-6"4'-0"5'-0"
(TYP)
'-6
(T
YP
3' -6
4' -0
'-0
115'-0"
WP-5
WEATHERABLE RIGID VINYL (PVC)
SHEET PILE (RETURN WALL)
4'-6"
247'-6"
1'-10"
18'-0"
3'-6"
STRUCTURAL FRP
COMPOSITE SHEET
PILE WALL
F S5.2
WP-6
KEY MAP
1 2 3
LEGEND
WORK LIMIT
0 EXISTING MAJOR CONTOUR
16 EXISTING MINOR CONTOUR
TB TOP OF BANK
STONE RIPRAP
EXISTING SHEET PILE
PROPOSED SHEET PILE
EXISTING TREE
NOTES
1. PROPOSED STRUCTURAL ELEMENTS ARE
SHOWN IN BLACK ON THIS SHEET SERIES.
ELEMENTS SHOWN IN GRAY INDICATE EXISTING
CONDITION.
2. SHEET PILE WALL PLAN TYPE I - FOR DETAIL
REFER SHEET S5.1.
3. SHEET PILE WALL PLAN TYPE II - FOR DETAIL
REFER SHEET S5.1.
4. THE LOCATION OF SUBSURFACE STRUCTURAL
ELEMENTS IS APPROXIMATE. ALL DEMOLITION
SHALL BE FIELD VERIFIED. CONTRACTOR SHALL
NOTIFY CONTRACTING OFFICER IN WRITING OF
ANY DISCREPANCIES IN PLAN.
5. THE WORKING POINTS (WP) ARE BASED ON
TOPOGRAPHIC SURVEY. THE CONTRACTOR
MUST SITE VERIFY ALL POINTS. ANY
DISCREPANCIES MUST BE REPORTED TO THE
CONTRACTING OFFICER.
6. THE CONTRACTOR MUST NOT REMOVE ANY
TREE FOR CONSTRUCTING DEADMAN WALL OR
INSTALLING TIE ROD. THE CONTRACTOR MUST
INFORM THE CONTRACTING OFFICER IF ANY
TREE IS PRESENT AT THE DEADMAN OR TIE ROD
LOCATION.
7. ALL PALM TREES AT THE EXCAVATION AREA
MUST BE PROTECTED DURING THE
CONSTRUCTION PERIOD IN ACCORDANCE WITH
FDOT FY 2026-27 STANDARD PLAN 110-100, TREE
PROTECTION AND PRESERVATION.
TIMUCUAN ECOLOGICAL & HISTORICAL PRESERVE
TITLE OF SHEET DRAWING NO.
PMIS
NO. SHEET
OF
A/E FIRM
PRIME/CIVIL/STRUCT:
191524
SUB SHEET NO.DESIGNED:
CADD:
TECH. REVIEW:
DATE:
AECOM
SAVANNAH, GA
335507
THIS ITEM HAS BEEN DIGITALLY SIGNED
AND SEALED BY ANIRBAN BHADRA
PROFESSIONAL ENGINEER, STATE OF
FLORIDA, LICENSE NO. 98875 ON THE
DATE INDICATED HERE. PRINTED COPY
OF THIS DOCUMENT ARE NOT CONSIDERED
SIGNED & SEALED. THE SIGNATURE
MUST BE VERIFIED ON ANY ELECTRONIC
COPIES.
GENERAL LAYOUT PLAN 2
22S1.2
BHADRA
KARTHI
POFF
04/01/2026
WORKING POINT TABLE
WORKING
POINT # NORTHING EASTING
WP-5 2220316.30 518329.67
WP-6 2220295.27 518321.56
SE
E
M
AT
C H
LI
N
E
SH
EE
T
S1 .3
SE
E
M
AT
C H
LI
N
E
SH
EE
T
S1 .1
10 20
-11
-9
-8
-7
-6
-4
-3
-2
-1
-10
-5
SCOUR PROTECTION
(STONE RIPRAP)
STRUCTURAL FRP
COMPOSITE SHEET
PILE WALL
STRUCTURAL FRP
SHEET PILE
(RETURN WALL)
RIPRAP
(RETURN WALL)
S3.2
B 115'-0"
WP-10
WP-9
WP-8
WP-7
7' -6
95'-0"
G S5.2
127'-6"
LEGEND
WORK LIMIT
0 EXISTING MAJOR CONTOUR
16 EXISTING MINOR CONTOUR
TB TOP OF BANK
TS TOP OF SLOPE
STONE RIPRAP
PROPOSED SHEET PILE
EXISTING TREE
NOTES
1. PROPOSED STRUCTURAL ELEMENTS ARE
SHOWN IN BLACK ON THIS SHEET SERIES.
ELEMENTS SHOWN IN GRAY INDICATE EXISTING
CONDITION.
2. THE WORKING POINTS ARE BASED ON
TOPOGRAPHIC SURVEY. THE CONTRACTOR
MUST SITE VERIFY ALL POINTS. ANY
DISCREPANCIES MUST BE REPORTED TO THE
CONTRACTING OFFICER.
3. THE CONTRACTOR MUST NOT REMOVE ANY
TREE FOR CONSTRUCTING DEADMAN WALL OR
INSTALLING TIE ROD. THE CONTRACTOR MUST
INFORM THE CONTRACTING OFFICER IF ANY
TREE IS PRESENT AT THE DEADMAN OR TIE ROD
LOCATION.
4. ALL PALM TREES AT THE EXCAVATION AREA
MUST BE PROTECTED DURING THE
CONSTRUCTION PERIOD IN ACCORDANCE WITH
FDOT FY 2026-27 STANDARD PLAN 110-100, TREE
PROTECTION AND PRESERVATION.
KEY MAP
1 2 3 GENERAL LAYOUT PLAN 3
23S1.3
BHADRA
KARTHI
POFF
TIMUCUAN ECOLOGICAL & HISTORICAL PRESERVE
TITLE OF SHEET DRAWING NO.
PMIS
NO. SHEET
OF
A/E FIRM
PRIME/CIVIL/STRUCT:
191524
SUB SHEET NO.DESIGNED:
CADD:
TECH. REVIEW:
DATE:
AECOM
SAVANNAH, GA
335507
THIS ITEM HAS BEEN DIGITALLY SIGNED
AND SEALED BY ANIRBAN BHADRA
PROFESSIONAL ENGINEER, STATE OF
FLORIDA, LICENSE NO. 98875 ON THE
DATE INDICATED HERE. PRINTED COPY
OF THIS DOCUMENT ARE NOT CONSIDERED
SIGNED & SEALED. THE SIGNATURE
MUST BE VERIFIED ON ANY ELECTRONIC
COPIES.
04/01/2026
WORKING POINT TABLE
WORKING
POINT # NORTHING EASTING
WP-7 2220252.24 518428.59
WP-8 2220202.31 518509.43
WP-9 2220159.73 518629.15
WP-10 2220153.20 518626.83
SE
E
M
AT
C H
LI
N
E
SH
EE
T
S1 .2
10 20
8" 15'-6"
±30'-0"
5'-0" VARIES
EXISTING PRECAST
CONCRETE DEADMAN
CORE DRILL 2" Ø HOLES THRU EXIST
PILES ALTERNATE SHEET PILES
EXISTING FILL
SG 750 PVC SHEET
PILE DEADMAN
(TYPE I AND II)
3" DIA OPEN END MAINTAINABLE
WEEP HOLE @ 6' O/C
EXISTING PVC SHEET PILE
3/4"Ø STEEL TIE ROD WRAP
WITH TAPE COATING SYSTEM
WEATHERABLE RIGID
VINYL (PVC) EXIST TIE RODS
IN PVC SLEEVED
EXISTING
GRADE
PROPOSED GRADE
IMPORTED
BACKFILL
INSTALL 2"x6" SALVAGE AND
NEW HORIZONTAL FACING
TIMBER BOARD
GRAVEL FILL
NOTE 4
EXCAVATE
AND BACKFILL
A S5.1
B S5.1
(+) 8.50 (TOP OF NEW WALL)
(+) 7.00 (EXISTING WALL TOP ELEVATION)
(+) 1.94 (MHW ELEVATION)
(-) 4.00 (ELEVATION)
(+) 3.50 (ELEVATION)
0.00 (ELEVATION)
(-) 8.50 (ELEVATION)
TURNBUCKLE
(TYP)
C C3.1
(+) 9.00 (PROPOSED GRADE)
(+) 3.00 (MINIMUM EXCAVATION LIMIT)
APPROXIMATE
EXISTING GRADE
10"
10"
1'-6"
1.0 2.0
WORK POINT COORDINATE
LOCATION INSTALL 2" THICK
TIMBER BOARD TO
COVER THE CAP
HAND INSTALL
RIPRAP SCOUR
PROTECTION
TYPICAL PVC SHEET PILE WALL SECTION IN FRONT OF EXISTING WALL
SCALE: 1" = 2'
A
S1.1 AND S1.2
NOTES
CONSTRUCTION SEQUENCE
EXISTING SHEET PILE WALL MODIFICATION
TIMUCUAN ECOLOGICAL & HISTORICAL PRESERVE
TITLE OF SHEET DRAWING NO.
PMIS
NO. SHEET
OF
A/E FIRM
PRIME/CIVIL/STRUCT:
191524
SUB SHEET NO.DESIGNED:
CADD:
TECH. REVIEW:
DATE:
AECOM
SAVANNAH, GA
335507
THIS ITEM HAS BEEN DIGITALLY SIGNED
AND SEALED BY ANIRBAN BHADRA
PROFESSIONAL ENGINEER, STATE OF
FLORIDA, LICENSE…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .