Attch 12 Addendum FTIG ACPs.pdf
PDF 8 MB Posted
- Attached to
- Construct Access Control Points Fort Indiantown Gap Federal contract opportunity
- Solicitation number
- W912KC21B0002
About this file
This invitation for bid solicits construction services for two Access Control Points at Fort Indiantown Gap in Pennsylvania. The scope of work includes constructing gate structures with canopies, a visitor control center, vehicle inspection areas, a gatehouse, and ID check stations, as well as installing perimeter fencing around 25% of the base. Additional requirements comprise active and passive protection systems, roadway configurations for traffic management and inspection, ballistic protection, security cameras, speed detectors, remote controlled barriers, communications equipment, and related infrastructure. The period of performance is 490 calendar days. The estimated value of construction is between $10 million and $25 million. This is a 100% small business set-aside with a NAICS code of 237310 and size standard of $39.5 million. A mandatory site visit is scheduled for August 10, 2021, with questions due via amendment. The solicitation contains three base line items and six additive line items in priority order for award to the offeror with the lowest aggregate amount within available funds.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Bid Opening Sign In W912KC21B0002.pdf | ||
| OF 1419 Bid Abstract W912KC21B0002 signed.pdf | ||
| W912KC21B00020002 Amendment 0002.pdf | ||
| Attach 14 0a-506_Addendum.pdf | ||
| Attach 15 3A-402_Addendum.pdf | ||
| Attach 13 Preaward RFIs W912KC21B0002.pdf | ||
| W912KC21B0002_0001 Amendment 1.pdf | ||
| Attch 6_Deletions of Funcks Utility Lines 1C_128_129 (1).pdf | ||
| Attch 8 ACP East Geotech Report.pdf | ||
| Attch 9_SF24.pdf | ||
| Attch 2_ACP Specifications_Vol2_FTIG_ACP.pdf | ||
| Attch 1_ACP Specifications_Vol1_DIV-1_10-28-20.pdf | ||
| Attch 11_SF25A.pdf | ||
| Attch 3 ACP Specifications_Vol3_FTIG_ACP.pdf | ||
| IFB W912KC21B0002.pdf | ||
| Attch 10_SF25.pdf | ||
| Attch 7_FTIG_WestACP_Geotech.pdf |
Show all 17
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FTIG ACPs 28 May 2021
ADDENDUM
Remove Section 23 09 23.02 per RFI 1 response
Remove Section 12 24 13 per RFI 6 response (Horizontal blinds used vice roller shades). Delete issued Sheet 0A-506 and incorporate attached revised Sheet 0A-506 which replaces reference to roller shades with horizontal blinds.
Delete issued Specification Section 34 72 00 and incorporate attached revised Section 34 72 00 which incorporates RFI 7 & 8 responses.
Delete issued Sheets 6T-509 and 6T-603 and incorporate attached revised Sheets 6T-509 and 6T-603 in accordance with the current Access Control Point (ACP) Center of Excellence standards for ACP certification.
Delete issued Sheet 6T-511 and incorporate attached revised Sheet 6T-511 which refers to Drawing 6E- 502 as per RFI 33 response.
STONE WAINSCOT
VENEER
3" CAVITY INSUL, R-19
MIN
AIR SPACE
CONC.
FOUNDATION
SEE STRUCT.
8" BURNISHED
BLOCK CMU
CONC. SIDWALK
WHERE OCCURS, SEE
CIVIL
1/2" EXPANSION JOINT
MATERIAL W/ BACKER ROD
AND SEALANT
CONC. SLAB
SEE STRUCT.
GRANULAR FILL
PERIMETER INSULATION
2'-0" UNDER SLAB AND TO
B.O. FOUNDATION WALL
VAPOR RETARDER
THROUGH WALL
FLASHING AND WEEPS
MASONRY
REINFORCEMENT @ 16"
O.C.
AIR/VAPOR BARRIER
GROUT SOLID
CONC. SPLASH
BLOCK SEE
/C8 0A-506
GUTTER, WHERE
OCCURS
3 5/8" 4 3/4" 7 5/8"
1' - 4"
METAL GUTTER
STANDING SEAM METAL
ROOF (SSMR)
METAL FASCIA
PANEL
METAL SOFFIT PANEL
BOND BEAM
SEE STRUCT.
BRICK VENEER
3" CAVITY INSUL, R-19 MIN
COLD-FORMED METAL
TRUSS
6" ROOF INSUL, R-40 MIN
PURLINS BY SSMR
MFR
METAL DECK
FLASHING
AIR SPACE
INFILL 3-5/8" METAL STUDS
BETWEEN TRUSSES
AIR/VAPOR BARRIER TO DECK
MASONRY REINFORCEMENT
@ 16" O.C.
0A-506
E8
3/4" EXTERIOR GRADE
PLYWOOD INFILL
2' - 6" 3 5/8" 4 3/4" 7 5/8"
MINERAL FIBER
BLANKET INSULATION
SNOWGUARD ROOF
SYSTEM, LOCATED ABOVE
EXTERIOR BEARING WALL,
FASTENED TO SSMR RIBS,
TYP ALL BUILDINGS
NOTE:
SEE ROOF PLAN FOR SNOQGUARD
ROOF SYSTEM LOCATIONS
0A-506
C7
PLAN
SECTION
2'-0"
3"
PRECAST CONCRETE
SPLASHBLOCK
4 X 4 - W 1.4 X W1.4 WWF
3" 1
"4
T.O. CMU
110' - 8"
1' - 4"
5/8" GYP
BOARD
3 5/8" METAL
STUDS TYP
ACOUSTICAL
CEILING SYSTEM
COLD-FORM
METAL TRUSS
5/8" GYP BOARD
CEILING
FOLDING GLASS
PARTITION HEAD
KNEE BRACE
@ 48" O.C.
T.O. CMU
110' - 8"
1 1/2" 6" 4 1/2"
ALUMINUM STOREFRONT
SYSTEM
PREFINISHED
CORROSION RESISTANT
FLASHING
CONT. BACKER ROD AND
SEALANT BOTH SIDES
WEEP HOLES
MORTAR - GROUT
1/2" THIN BRICK
VENEER
THIN BRICK
SUPPORT PANEL
3/4" EXTERIOR
GRADE PLYWOOD
COLD-FORMED
METAL TRUSS
AIR/VAPOR
BARRIER
7/8" HAT CHANNEL
METAL SOFFIT
PANEL
BATT INSULATION
METAL DECK
6" ROOF INSUL,
R-40 MIN
BENT CLIP BOTH
SIDES OF STUDS, SEE
STRUCT.
CONT. TRACK
BETWEEN TRUSSES
STANDING SEAM
METAL ROOF (SSMR)
ANGLE, SEE STRUCT.
STEEL BEAM, SEE
STRUCT.
ANGLE, SEE STRUCT.
6" METAL STUDS
3-5/8" METAL STUDS
(CEILING)
GYPSUM BOARD
HORIZONTAL BLIND
WHERE OCCURS
6" x 18GA. GALV.
BOTTOM TRACK
PAINTED COLUMN
BEYOND, SEE
STRUCT.
PURLINS BY
SSMR MFR
0A-506
C7
SECTION A - A
A
A
1/16" NEOPRENE PAD
ENTRANCE MAT
FINISH
FLOORING
AS SCHEDULED
CONCRETE
SLAB
1/16" NEOPRENE
PAD
FINISH FLOORING
AS SCHEDULED
/2
/2
T.O. CMU
110' - 8"
PRE-FINISHED
METAL GUTTER
METAL
FASCIA PANEL
PRE-FINISHED METAL
SOFFIT TRIM
7/8" HAT CHANNEL
METAL SOFFIT PANEL W/
CONCEALED ANCHORS
STANDING SEAM
METAL ROOF (SSMR)
METAL FLASHING
6" ROOF INSUL,
R-40 MIN
METAL DECK
WOOD
BLOCKING
BENT PLATE
SEE STRUCT
COLD-FORMED
METAL TRUSS
MINERAL FIBER
BLANKET
INSULATION
SEALANT
ICE AND WATER
BARRIER BETWEEN
FLASHING AND
INSULATION
20 GA STRAPS
AT 16" O.C.
METAL STUDS
RIGID
INSULATION
AIR/VAPOR
BARRIER
3/4" EXTERIOR
PLYWOOD
BACKER ROD
AND SEALANT
METAL DECK
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
0A-506
G E
N E
R A
L D
E T
A
IL
S
F O
R T
I N
D
IA
N T
O W
N G
A P
P
A
B A
L T
IM
O
R E
D
IS
T R
IC
T
H D
R E
N G
IN
E
E R
IN
G
IN
C
S
T
H S
T R
E E
T O
M A
H A
N
E
(4
-1
K .T
O U
R E
K
K .T
O U
R E
K
J .S
M
IT
H
S .H
E A
N E
Y
O C
T
F -8
-1
-1
FINAL DESIGN
M A
IN
A
C C
E S
S C
O N
T R
O L P
O
IN
T
P R
O J E
C T
1 1/2" = 1'-0"E1
WALL BASE DETAIL
1 1/2" = 1'-0"E4
EAVE DETAIL
1 1/2" = 1'-0"C8
SPLASH BLOCK DETAIL
1 1/2" = 1'-0"B1
BULKHEAD DETAIL
1 1/2" = 1'-0"B4
WINDOW HEAD DETAIL
1 1/2" = 1'-0"A8
WALK OFF MAT
3" = 1'-0"E8
GUTTER DETAIL
1'0 6"3"
SCALE: 3" = 1'-0"
2'0 1'6"
SCALE: 1 1/2" = 1'-0"
3" = 1'-0"C7
TOP OF WALL DETAIL
A
G
R
GREEN INDICATING LIGHT
RED INDICATING LIGHT
AMBER INDICATING LIGHT
CONTROL SWITCHES
PB CONTROL SWITCH W/ HEAD GUARD
SELECTOR SWITCH
KEY OPERATED CONTROL SWITCH
EFO SWITCH WITH SAFETY COVER AND
KEYED RESET
PIEZO SOUNDER
NOTE 4
LEGEND
GENERAL NOTES :
A. THE CONTROL PANEL LAYOUTS DEPICT AN ACP
WITH A GATEHOUSE, SEARCH OFFICE 3 ID CHECK
LANES, AN OVERWATCH POSITION, AND 4 ACTIVE
VEHICLE BARRIERS.
B. SEE UFGS 34 41 26.00 10 "ACCESS CONTROL POINT
CONTROL SYSTEM" APPENDIX A "SIGNS AND
SIGNALS SAFETY SYSTEM" FOR DESCRIPTIONS OF
THE REQUIRED BARRIER AND TRAFFIC CONTROL
SEQUENCES.
C. THE BARRIER MODE SELECTOR SWITCHES,
BARRIER "DOWN" AND "UP" SWITCHES AND THE EFO
RESET SWITCH MAY BE LOCATED ON A SEPARATE
PANEL CALLED THE MAINTENANCE PANEL. THE
MAINTENANCE PANEL MUST BE LOCATED IN THE
GATEHOUSE IN AN AREA OR CABINET THAT IS ONLY
ACCESSIBLE TO THE CHIEF OF THE GUARDS.
NOTES :
1. PROVIDE A SEPARATE STAND ALONE EFO PUSH BUTTON SWITCH WITH KEYED RESET AND SAFETY
COVER MOUNTED ON THE INSIDE OF THE GUARD BOOTH TO THE LEFT OF THE DOOR FRAME FOR
EASY ACCESS BY THE GUARD WHO MAY BE STANDING OUTSIDE GUARD BOOTH DURING ID CHECKS.
2. THE BARRIER MODE SELECTOR SWITCHES SHALL BE KEY OPERATED WITH THE KEY REMOVABLE IN
ALL MODES. EACH BARRIER SHALL HAVE A UNIQUE KEY.
a. UNDER NORMAL OPERATIONS, THE BARRIER MODE SELECTOR SWITCHES WILL BE IN THEIR
EMERGENCY FAST OPERATE (EFO) POSITIONS WITH KEYS REMOVED AND STORED IN A LOCKED
CABINET IN THE GATEHOUSE ACCESSIBLE ONLY BY THE CHIEF OF THE GUARDS.
b. WHEN PERFORMING BARRIER MAINTENANCE, MAINTENANCE PERSONNEL WILL OBTAIN THE KEY
FROM THE CHIEF OF THE GUARDS, PUT THE SWITCH IN THE "LOCAL" POSITION, AND THEN
REMOVE AND RETAIN THE KEY. THE MAINTENANCE PERSON WILL THEN PUT THE KEY IN THE
MODE SELECTOR SWITCH ON THE BARRIERS LOCAL CONTROL PANEL LOCATED AT THE BARRIER
AND TURN THE KEY TO THE "LOCAL" POSITION TO ACTIVATE THE OPEN AND CLOSE SWITCHES ON
THE LOCAL CONTROL PANEL. WHEN MAINTENANCE IS COMPLETE, THE MAINTENANCE
PERSON WILL PLACE THE MODE SELECTOR SWITCH ON THE LOCAL CONTROL PANEL BACK TO
"AUTO" MODE, REMOVE THE KEY, AND RETURN THE KEY TO THE CHIEF OF THE GUARDS. THE
CHIEF OF THE GUARDS WILL USE THE KEY TO PLACE THE BARRIER'S MODE SELECTOR SWITCH
ON THE MASTER CONTROL PANEL IN THE "EFO" POSITION, AND THEN WILL REMOVE AND LOCKUP
THE KEY.
c. A GUARD MAY TEST OPERATE A BARRIER BY FIRST OBTAINING THE BARRIER'S MODE SWITCH
KEY FROM THE CHIEF OF THE GUARDS, PUTTING THE MODE SWITCH IN THE "TEST" POSITION, AND THEN OPENING OR CLOSING THE BARRIER WITH THE PUSHBUTTONS ON THE MASTER
CONTROL PANEL. UPON COMPLETION OF THE TEST OPERATIONS, THE GUARD WILL RETURN
MODE TO "EFO", REMOVE THE KEY, AND RETURN IT TO THE CHIEF OF THE GUARDS. PROCEDURES
MUST BE IN PLACE TO ENSURE ALL OPERABLE BARRIERS' MODE SELECTOR SWITCHES ARE
PLACED IN THE EFO POSITIONS FOR THE PROPER RESPONSE TO AN EFO COMMAND.
RAVB EFO ARMED YES
ACTIVATED
R
AVB EMERGENCY
FAST OPERATE
K
K
GCP
GCP
ACTIVATED
LAMP
TEST
GCP
R
ENABLED
YES
ENABLED
NO
R
G
R
WRONG-WAY
STATUS
RESET
EMERGENCY
AVB EFO
NOTE 6
R
DURESS
SWITCH
NOTES:
1. "AVB EMERGENCY FAST OPERATE" BOX IS TO BE RED IN COLOR.
LAMP
TEST
(NOTE 3)
WRONG WAY
NOTE 5
R YES
ACTIVATED
R
AVB EMERGENCY
FAST OPERATE
AVB EFO
NOTE 1
LAMP
TEST
(NOTE 3)
ALARM
SILENCE
NOTE 6
EFO
K
K
GCP
WRONG WAY
NOTE 5
UP
DOWN G
R
RTROUBLE
ID CHECK
GATE ARM
F1
LOCAL CONTROL PANEL (CLIN 0007)
NOT TO SCALE
SEARCH OFFICE
D1
LOCAL CONTROL PANEL
NOT TO SCALE
PORTABLE AVB OVERWATCH
3. LAMP TEST PUSH BUTTON SHALL TURN ON ALL INDICATING LIGHTS WHILE
BUTTON IS PUSHED WITHOUT EFFECTING ANY CONTROLS.
4. THE INDICATING LIGHT LABELED 'TROUBLE' SHALL COME ON FOR ANY PROBLEMS
OR ALARM CONDITIONS AT THE BARRIER, e.g. LOW VOLTAGE, ETC. THE INDICATING
LIGHT LABELED 'VPD ON' SHALL COME ON WHEN ANY OF THE BARRIER'S VEHICLE
PRESENCE DETECTORS (VDL'S) GETS A CALL (VEHICLE DETECTED) FOR MORE THAN
15 SECONDS.
5. WRONG-WAY, AND DURESS ALARMS SHALL INCLUDE BACK LIT WINDOWS
AND ADJUSTABLE AUDIBLE ALARMS. DURESS ALARMS SHALL BE ON OVERWATCH
POSITION PANEL AND GATEHOUSE PANEL ONLY. DURESS ALARM
ACKNOWLEDGEMENT SWITCH SHALL BE ON GATEHOUSE PANEL ONLY.
6. OVERWATCH POSITION PANEL SHALL INCLUDE A DURESS ALARM SILENCE SWITCH TO
SILENCE THE AUDIBLE ALARM. ALL WRONG WAY ALARMS SHALL BE SELF CLEARING.
7. VOLUME ADJUST ABLE PEIZO SOUNDER.
8. BASE BID: PROVIDE EFO SWITCH ON SEARCH AREA CANOPY. INCLUDE IN SEC0501.
SEE C8/6T-510 FOR EFO SWITCH DETAILS.
CLIN 0007: PROVIDE EFO SWITCH ON CONTROL PANEL AS INDICATED IN ADDITION TO
EFO SWITCH ON CANOPY. INCLUDE IN SEC0401.
D4
LOCAL CONTROL PANEL
NOT TO SCALE
ID CHECK WITH AVB EVO SWITCH
D6
OPEN SWITCH
NOT TO SCALE
ID CHECK AVB EMERGENCY FAST
AVB
EFO
ARMED
E7
LOCAL CONTROL PANEL
NOT TO SCALE
GATEHOUSE
D
UP
DOWN G
R
RTROUBLE
SEARCH AREA
ENTRANCE
GATE
YES
NO
NO
YES
G
R
OVERWATCH POSITION AVB EFO ARMED
G
R
ID CHECK 01
AVB EFO ARMED
YES
NO G
R
ID CHECK 02
AVB EFO ARMED
YES
NO
R
POWER
NOYES NOYES NOYES
UP
DOWN
R
R
TROUBLE
WRONG WAY
NOTE 5
G
R
ID CHECK 03
AVB EFO ARMED
YES
NO
NOYES
LAMP
TEST
(NOTE 3)
UP
DOWN G
R
RTROUBLE
ID CHECK
GATE ARM
LANE - 1
ALARM
SILENCE
DURESS
ACK
UP
DOWN G
R
RTROUBLE
SEARCH AREA
ENTRANCE GATE
RVPD ON
LOOP
RELEASE
INBOUND FINAL AVB
UP
DOWN G
R
RTROUBLE
ID CHECK
GATE ARM
LANE - 2
UP
DOWN G
R
RTROUBLE
ID CHECK
GATE ARM
LANE - 3
NOTE 3
G
R
SEARCH AREA
AVB EFO ARMED
YES
NO
NOYES
R ACT R ACT R ACT R ACT
ALARM
SILENCE
NOTE 7
NOTE 6
K
NOTE 7
CAB TAMPER
COMM LOSS
PNL TAMPER
NOTE 7
R
R
VDP ON
INSIDE AVB
UP
DOWN
R
R
OUTSIDE AVB
R
LOOP
RELEASE
UP
DOWN
TEST
R
EFO LOCAL
EFO
MODE
R
TROUBLE
INBOUND FINAL AVB
R
R
VDP ON
INSIDE AVB
A
UP
DOWN
R
R
OUTSIDE AVB
R
LOOP
RELEASE
NOTE 2
UP
DOWN
OFF
R
LOCAL
R
TROUBLE
MAINTENANCE CONTROL PANEL
R
INSIDE AVB
UP
DOWN
R
R
OUTSIDE AVB
ALARM
SILENCE
NOTE 7
LAMP
TEST
(NOTE 3)
G
D9
MAINTENANCE LOCAL CONTROL PANEL
NOT TO SCALE
NOTES:
1. FURNISH ONE MAINTENANCE CONTROL PANEL FOR EACH
DIRECTION OF TRAVEL.
ALARM
SILENCE
NOTE 7
NOTE 6
EFO
TEST
MODE
A
EFO
LOCAL
MODE
A
TEST
EFO LOCAL
EFO
MODE
A
EFO
TEST
MODE
A
EFO
LOCAL
MODE
A
NOTE 8
S O
L I C
I T
A T
I O
N
N
O
D E
S I G
N E
D
B
Y
D E
S C
R I P
T I O
N
M A
R K
S I Z
E
S U
B M
I T
T E
D
B
Y
D A
T E
C O
N T
R A
C T
N
O
C H
E C
K E
D
B
Y
D R
A W
N
B
Y
I S
S U
E
D
A T
E
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
US Army Corps of Engineers
U S
A
R M
Y
C
O R
P
F
E
N G
I N
E E
R S
H D
R
E
N G
I N
E E
R I N
G
I N
C
S
T
H
S
T R
E E
T
O
M A
H A
N
E
B A
L T
I M
O R
E
D
I S
T R
I C
T
O C
T
A N
S I
D
F O
I
D I A
N T
O W
N
G
A P
P
A
M A
C
E S
S
C
O N
T R
O L
P
O I N
T
P R
O J E
FINAL DESIGN
F
D
R O
B E
R T
S
M
H O
F R
E I T
E R
S
W I C
K S
J
S M
I T
H
A C
P
S
E C
U R
I T
Y
D
E T
A I L S
6T-509 c:\pwworking\central01\d0708585\10078599-FIGW-1T-501.dwg
30 October 2019 1:48 PM Brandt, Jill C.
EFO
RESET
NOT USED.
NOTE 9
9. AREA AROUND EFO SWITCH SHALL BE RED.
OUTBOUND
NOT USED.
3. REFER TO 2/6E-502 FOR FOUNDATION DETAILS.
1. REFER TO 2/6E-502 FOR FOUNDATION DETAILS.
x(2) (3)xx(2) (3)x x(2) x(2)
Access Control Points FTINDIANTOWN
SECTION 34 72 00.00
PASSIVE BOLLARD AND CABLE-BASED PASSIVE VEHICLE BARRIERS
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.
ASTM INTERNATIONAL (ASTM)
ASTM A1023/A1023M (2009; E 2012) Standard Specification for Stranded Carbon Steel Wire Ropes for General Purposes
ASTM D698 (2012; E 2014; E 2015) Laboratory Compaction Characteristics of Soil Using Standard Effort (12,400 ft-lbf/cu. ft.
(600 kN-m/cu. m.))
ASTM D2487 (2017) Standard Practice for Classification of Soils for Engineering Purposes (Unified Soil Classification System)
ASTM F2656 (2007) Standard Test Method for Vehicle Crash Testing of Perimeter Barriers
ASTM F2656/F2656M (2018) Standard Test Method for Crash Testing of Vehicle Security Barriers
U.S. DEPARTMENT OF STATE (SD)
SD-STD-02.01 (2003; Rev A) Specification For Vehicle Crash Test of Perimeter Barriers and Gates
1.2 BARRIER SYSTEM DESCRIPTION
Provide a complete passive vehicle barrier system meeting design and performance requirements presented in this Specification Section and in the Contract Drawings. Vehicle barriers covered by this Specification Section include post/cable barriers.
1.3 CRASH RESISTANCE REQUIREMENTS
Minimum performance requirements for the barriers are provided in this Specification Section. Similar-type vehicle barriers meeting higher crash resistance rating may be submitted for approval.
1.3.1 Impact Condition
Make the passive cable vehicle barriers to withstand an impact corresponding to DOS SD-STD-02.01, Impact Condition shall be as indicated on the Contract Drawings.
SECTION 34 72 00.00 Page 1
Make the passive bollard vehicle barriers to withstand an impact corresponding to ASTM F2656/F2656M, Impact Condition shall be as indicated at various locations on the Contract Drawings.
1.3.2 Penetration Rating
For DOD certified barriers, use the Penetration Rating indicated on the Contract drawings.
1.4 CRASH RESISTANCE DEMONSTRATION OF COMPLIANCE
Submit a DoD letter of Certification as demonstration of compliance with the specified crash resistance requirements for each manufactured passive vehicle barrier proposed for this project.
1.5 SUBMITTALS
Government approval is required for submittals with a "G" designation;
submittals not having a "G" designation are for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. The following shall be submitted in accordance with Section 01 33 00.00 06 SUBMITTAL
PROCEDURES:
SD-02 Shop Drawings
Shop Drawing; G AE
SD-03 Product Data
Data Sheets; G, AE
SD-05 Design Data
Analysis Report; G, AO
SD-07 Certificates
Installer Certification; G AO
DOD Letter of Certification; G AO
SD-08 Manufacturer's Instructions
Manufacturer's Written Installation Instructions
Coating Repair Instructions
SD-09 Manufacturer's Field Reports
Manufacturer Verification
Contractor/Installer Verification
Concrete Strength Reports
Soil Compaction Reports
SECTION 34 72 00.00 Page 2
Manufacturer Inspection Reports
SD-10 Operation and Maintenance Data
Operation And Maintenance Manual
SD-11 Closeout Submittals
Warranty
Spare Parts
1.6 QUALITY ASSURANCE
1.6.1 Manufacturer
Use a company specializing in manufacturing the products specified in this Specification Section.
1.6.2 Installers
Submit installer certification stating that the installers are certified (if the manufacturer provides installer certifications) or trained by the manufacturer in the installation of the specific manufacturer's barriers being installed.
1.6.3 Contractor Project Manager
Designate a Project Manager for all work under this Specification Section.
Require the Project Manager to provide technical and managerial leadership to all contractor personnel, subcontractors, engineers, inspectors and surveyors during the design and installation phases of this Work.
Require the Project Manager to have experience in the design, manufacture, and installation of similar barriers.
1.6.4 Engineers
Submit Engineer Qualifications showing that the Engineer providing the demonstration of crash rating compliance analysis has formal training in dynamic finite element analysis with a minimum of five years experience in performing non-linear dynamic analysis.
1.6.5 As-Certified Certification
Submit written verification that vehicle barriers provided under this contract are the As-Certified configurations.
1.6.6 Installation Certification
Submit written verification that the vehicle barriers provided under this contract are installed in the As-Certified configurations, including soil conditions at foundations.
1.6.7 Pre-Installation Conference
Conduct a pre-installation conference with all associated subcontractors.
SECTION 34 72 00.00 Page 3
1.7 DELIVERY, STORAGE AND HANDLING
Protect components delivered to site and/or placed in storage from the weather, humidity, and temperature variation, dirt and dust, or other contaminants. Store structural materials on sleepers or pallets and protect them from rust and objectionable materials such as dirt, grease, or oil. Handle all components to protect finish and coatings from scuffs, abrasions or other damage. Damage to factory applied finishes and coatings can be cause for rejection.
Provide all other delivery, storage and handling protections as recommended by the manufacturer.
1.8 PROJECT SITE CONDITIONS
1.8.1 Environmental Requirements
Ensure that all materials, equipment and installation techniques are appropriate for the prevalent temperature conditions at the installation location. Ensure the installation is in conformance with the manufacturer's written environmental requirements.
1.8.2 Existing Conditions
1.8.2.1 Site Survey Report
A topographic site survey report is included as part of the Contract Documents and can be found in the Contract Drawings.
1.9 WARRANTY
Submit the manufacturer's complete warranty for materials, workmanship, and installation for five years from the time of project completion. Do not prorate.
1.10 SPARE PARTS
Provide a manufacturer's standard recommended spare parts package with detailed manuals on parts replacement, with each barrier to facilitate one year of normal operations.
1.11 DATA SHEETS
Submit Data Sheets, including catalog cuts, illustrations, schedules, diagrams, performance charts, instructions and brochures illustrating size, physical appearance and other characteristics of materials, systems or equipment for all components of vehicle barriers.
PART 2 PRODUCTS
2.1 DoD CERTIFIED BOLLARD AND POST/CABLE BARRIERS
Provide bollard and post/cable barriers that are approved in accordance with one of the following:
a. Included on the list of DOD Anti-Ram Vehicle Barriers maintained by the US Army Corps of Engineers (USACE)-Protective Design Mandatory Cneter of Expertise (PD-MCX).
SECTION 34 72 00.00 Page 4
b. Reserved.
In addition to meeting the general requirements listed in this Specification Section, ensure the DOD standard bollard and post/cable barriers conform to the following barrier-specific requirements.
2.1.1 Alterations to Design
Do not modify designs shown on drawings and or as certified..
2.1.2 Concrete
Concrete strength is as shown on the drawings and as specified in Section
03 30 00.00 10 CAST-IN-PLACE CONCRETE.
2.1.3 Reinforcing Steel
Reinforcing steel is fy = 60,000 psi unless otherwise noted on the drawings, and as specified in Section 03 20 01.00 10 CONCRETE
REINFORCEMENT.
2.1.4 Cable
Provide cable as shown on the drawings and per requirements of ASTM A1023/A1023M . No substitutions are acceptable.
2.1.4.1 Pipe Steel
Provide pipe steel as shown on the drawings and provide hot dipped galvanized. Provide steel finishes as specified in Section 09 90 00
PAINTS AND COATINGS.
2.1.4.2 Over-excavation and Backfill
Over-excavate soil below walls by at least 12 inches and backfill with any materials classified by ASTM D2487 as GW, GP, GM, GP-GM, GW-GM, GC, GP-GC, GM-GC, SW, SP. Ensure the soil is free of debris, roots, wood, scrap material, vegetation, refuse, soft unsound particles, and frozen, deleterious, or objectionable materials. Unless specified otherwise, make the maximum particle diameter one-half the lift thickness at the intended location.
Compact the 12 inches of over-excavation to 95 percent of ASTM D698 (unless noted otherwise on the drawings). Backfill areas of over-excavation at sides of walls to meet same fill and compaction requirements. Make the maximum lifts for over excavation and backfill 6 inches.
2.1.5 Terminal and Line Post Spacing
Ensure the spacing of line and terminal posts meets the minimal DoD certified requirements; spacing of posts shall be designed by the Contractor and submitted for approval.
SECTION 34 72 00.00 Page 5
2.2 COMPONENT REQUIREMENTS
2.2.1 Single Manufacturer
Ensure a single manufacturer supplies all parts, components, accessories, fittings and fasteners as required by manufacturer's written requirements, manufacturer's written installation instructions and written warranty, unless otherwise noted in this Specification Section.
2.2.2 Metal Component Primer and Color
Ensure all above ground metal components are hot dipped galvanized unless otherwise specified.
2.2.3 Grounding System
Provide grounding system in accordance with Section 28 05 26.00 40
GROUNDING AND BONDING FOR ELECTRICAL SAFETY AND SECURITY.
2.3 ACCESSORIES
Provide all accessories as required for a complete and finished barrier system. Accessories to be, at a minimum, as required by manufacturer's instructions.
2.4 FABRICATION
2.4.1 Shop Assembly
Shop assemble the vehicle barriers to the greatest extent possible.
2.5 TEST,INSPECTIONS ND VERIFICATIONS
2.5.1 Manufacturer Verification
Provide written verification that vehicle barriers provided under this contract conform to the "As-Certified certification" configurations, based on the anti-ram crash testing.
2.5.2 Contractor/Installer Verification
Provide written verification that the vehicle barriers provided under this contract are installed per the "As-Certified certification" configurations, based on the Crash Test Report or Analysis Report.
2.6 SHOP DRAWINGS
Show the locations of openings on the Shop Drawings. Submit Shop Drawings that include layout, locations, components, materials, dimensions, sizes, weights, finishes of components, installation and operational clearances, terminal and line post sizes and locations, spacing and details of post anchorage, and post attachment/bracing, and other pertinent details as applicable. Provide Crash Test Report and testing lab as-built certification drawings or Analysis Report at the same time as the Shop Drawings. Shop Drawings cannot be approved without the corresponding Crash Test Report or Analysis Report.
SECTION 34 72 00.00 Page 6
PART 3 EXECUTION
3.1 EXAMINATION
3.1.1 Sub-surface Conflicts
Verify all existing conditions prior to performing any work. Locate all underground utilities and structures, including publicly and privately owned, prior to excavating. Coordinate with all involved parties in order to accomplish indicated work with minimal interference to existing underground utilities and structures. If unforeseen conditions exist that prohibit the execution of work as indicated, immediately coordinate with Contracting Officer for viable alternative solutions.
3.2 PREPARATION
3.2.1 Layout
All vehicle barrier installations shall be laid out and certified by a Registered Professional Land Surveyor in accordance with the Contract Documents and approved Shop Drawings, prior to installation.
3.2.2 Soil Conditions
3.2.2.1 Comparable Soils
Certify that the existing soil conditions are comparable to those in the Crash Test Reportor Analysis Report. If not, either remedy the soil conditions at each foundation point or provide additional testing to verify that the actual soil conditions provide the required performance.
3.2.3 Grade Between Terminal Posts
Ensure that the grade between terminal posts (and for no less than 10 feet on either side of the vehicle barriers, along the running length) is constant such that the cables consistently match the design distance from grade between terminal posts.
3.2.4 Interference with Existing Utilities
Based on Contract Drawings, survey, utility locating activities and approved Shop Drawings. Identify areas of interference with existing utilities and propose mitigating measures (with supporting analysis if mitigating measures require modifications to the typical foundation details) to remedy the interference conditions.
3.2.5 Protection
Ensure that adjacent structures, utilities, and roadways are protected from damage during construction.
3.3 INSTALLATION
3.3.1 Contractor's Project Manager Oversight
Contractor's project manager shall oversee all vehicle barrier installation activities.
SECTION 34 72 00.00 Page 7
3.3.2 Trained or Certified Installers
Vehicle Barriers shall be installed by manufacturer trained or certified installers in accordance with manufacturer's written installation instructions. Submit Manufacturer's Written Installation Instructions.
3.3.3 Manufacturer's Representative
Manufacturer's representative is required to observe or inspect vehicle barrier installation
3.3.4 Vertical Alignment
Install all vertical elements plumb and in alignment with a tolerance of 1/2 inches.
3.3.5 Horizontal Alignment
Install all horizontal elements in the alignment indicated on the approved Shop Drawings with a tolerance of 1/2 inches in 6 feet-6 inches.
3.3.6 Field Welding
Field welding is unacceptable as it will cause significant damage to the galvanizing and powder coat protective finishes.
3.3.7 Field Cutting and Drilling
Avoid unnecessary cutting and drilling of pre-finished components. If necessary to cut or drill or otherwise modify product due to field conditions, repair factory finish in accordance manufacturer's written installation instructions.
3.4 FIELD QUALITY CONTROL
3.4.1 Test Reports
Submit Concrete Strength Reports Soil Compaction Reports Manufacturer Inspection Reports.
3.4.2 Reinforcing Steel Inspection
Ensure all reinforcing steel is inspected by Contractor's project manager prior to concrete placement. Provide no less than 2 days notice of concrete placement schedule to required inspection personnel.
3.5 OPERATION AND MAINTENANCE MANUAL
Submit written Operation and Maintenance Manual.
3.5.1 Periodic AInspection and Testing
As part of the Operation and Maintenance Manual, provide periodic inspection and testing recommendations for daily, weekly, monthly and yearly intervals.
SECTION 34 72 00.00 Page 8
3.6 ADJUSTING AND CLEANING
3.6.1 Clean Job Site
Clean job site.
3.6.2 Above Ground Components
Thoroughly clean all above ground components of concrete spatter and dirt.
3.6.3 Tensioning
After installing all barriers, ensure that the tensioning of all cable and fence fabric is in accordance with manufacturer's written installation instructions.
3.7 REPAIR
3.7.1 Metal Finishes
Repair damage to galvanized, coated, painted finishes in accordance with manufacturer's written installation instructions. In the case where the manufacturer does not have written instructions, submit recommended coating repair instructions (referencing published standards) for approval.
-- End of Section --
SECTION 34 72 00.00 Page 9
THIS PAGE INTENTIONALLY LEFT BLANK
SECTION 34 72 00.00 Page 10
FTIG ACPs 2 June 2021
ADDENDUM #2
1. Delete issued Sheet 1C-133 and incorporate attached C.3.0_REV-1 as the new Sheet 1C-133 as per RFI 4.c.
response.
2. Incorporate attached Sheet C.4.2. as per RFI 4.c. response. Figures on the table on this drawing take precedence over elevations shown in the diagram above the table.
3. On attached C.4.2, change “FTIG Rye Tan Mix” in the diagram to “FTIG ITAM Mix”. Add the following to Specification Section 34 72 00 Para 2.1.3 Seed Formulas:
FTIG ITAM Mix (requires inoculant)
a. 25% Annual Ryegrass
b. 10% Perennial Ryegrass (Saint variety preferred)
c. 20% Medium Red Clover
d. 10% White Ladino Clover
e. 10% White Dutch Clover
f. 10% Vernal Alfalfa
g. 10% Norcen Birdsfoot Trefoil
h. 5% Crimson Clover
FTIG ACPs 4 June 2021
ADDENDUM #3
1. Delete issued Specification Section 34 71 13.19 and incorporate attached revised Section 34 71 13.19 which in accordance with the current Access Control Point (ACP) Center of Excellence standards for ACP certification
2. Delete issued Specification Section 23 09 23.02 for the 24/7 thermostats and incorporate the revised 23 09 13 spec per RFI #1 response.
3. On Sheet 7C-103 delete reference to CLIN 0005 14’ M50, P-2 Crash Beam. On Sheet 7C-001, in General Note 1, change “SEE SHEETS 7C-401 AND 7C-402 FOR CLIN 0006, ELECTRONIC CRASH BEAMS” to “SEE SHEET 7C-401 FOR CLIN 0006, ELECTRONIC CRASH BEAMS”. Sheet 7C-402 shows this crossing of Asher-Miner Road correctly. RFI 35 Response incorrectly identified this P-2 Crash Beam as CLIN0005 when it is in fact CLIN0006.
4. Delete issued Specification Section 33 34 00 Force Mains Sewer as the Force Main was deleted from the project.
FTIG ACPs 9 June 2021
ADDENDUM #4
The Government’s intent is that the contractor’s bid in CLIN 0003 for the Main ACP gas services is for the contractor, in concert with UGI, to build the gas line connection as shown on Sheets 1C-129 & 1C-130. While UGI will not allow the contractor to lay pipe and make connections, UGI will allow for the contractor to excavate and place bedding and backfill the trench in accordance with UGI’s standards. The contractor’s bid should include his own work as well as an estimated amount for UGI’s connection work.
The contractor should note that the actual connection point is at least 220 feet to the east in front of Building 8- 63 from what is shown on Sheet 1C-130. See attached photo for approximate locations of current UGI service in the area.
The Government will continue to work with UGI to prepare for the installation of this line. The Government will pay the difference between the contractor’s projected price as bid and actual UGI costs at time of installation.
This includes any changes UGI requires from the contract drawings provided on the solicitation. The contractor’s price will include the 220’ of additional line mentioned above from the matchline shown on Sheet 1C-130 in the vicinity of Keynote 3.
The bid package pricing for CLIN 0003 shall be documented at time of bid to show estimated UGI connection price in the body of the line item, with the total of all work associated with CLIN 0003 (including estimated connection price) on the Amount line.
FTIG ACPs 10 June 2021
ADDENDUM #5
1. Delete issued Sheet 1C-503 and incorporate attached 1C-503 as per RFI 55 response.
2. Delete issued Specification Section 13 34 23 PREENGINEERED GUARD BOOTH STRUCTURES and incorporate the revised 13 34 23 spec per RFI #59 response.
08067
Q-003
08063
Q-004 pool h 2
08065
08069 Q-005
Garage
Q-002
08080
Garage 08064 pool h
08071
08066
08070
08068
Fort Indiantown Gap:
Gas Utility Line ACP Main
FORT INDIANTOWN GAP
ANNVILLE, PENNSYLVANIA
Produced and printed by: JMD Comm: (717) 861-9558 µ
0 0.05 0.1 0.150.025 Miles
Coordinate System: WGS 1984 UTM Zone 18N
Date: 6/9/2021
Gas Utility Line
Building
DRAFT: The information on this map is for planning purposes only. This information is not adequate for legal boundary definition, regulatory interpretation, or parcel-level analysis.The data on this map are based on the best available information existing at this time.
This map is a "living document" intended to be updated as new data become available and are incorporated into the GIS database.
6"
MIN
8"
MIN
2"
CURB NOTES:
1. PROVIDE MATERIALS AND CONSTRUCTION MEETING THE REQUIREMENTS OF
PUBLICATION 408, SECTION 630 FOR PLAIN CEMENT CURB AND DEPRESSED
CURB,SECTION 640 FOR PLAIN CEMENT CONCRETE GUTTER AND SECTION 641
FOR PLAIN CEMENT CURB GUTTER.
2. SPACE CONTRACTION JOINTS IN UNIFORM LENGTHS OR SECTIONS.
3. PLACE 20 (3/4") THICK PREMOLDED EXPANSION JOINT FILLER MATERIAL AT
STRUCTURES AND AT THE END OF THE WORK DAY. CUT MATERIAL TO CONFORM
TO CROSS SECTIONAL AREA OF CURB.
E1
VERTICAL CURB
NOT TO SCALE
DETAIL A
CONTRACTION JOINT
PLAIN CEMENT
CONCRETE CURB
7"1"
8"
1/4" RADIUS
TOPSOIL OR
SIDEWALK AS
REQUIRED BY
LOCATION
(2) #5 CONT
EXCEPT AT
THRU JOINTS
8" MIN BASE COURSE PER
SPECIFICATION 32 11 20
GEOTEXTILE FABRIC
ASPHALTIC OR PORTLAND
CEMENT CONCRETE
ROADWAY SECTION
3/4" RADIUS
TACK COAT AT INTERFACE
FOR ASPHALT CEMENT OR
EXPANSION JOINT FOR PCC -
SEE A1/1C-502
C
O
N
T
R
A
C
T
I
J
I
A
C
I
N
G
COMPACT BACKFILL TYP.
M
X
N
CONTRACTION JOINT,
SEE DETAIL A.
PCC CONCRETE PER SPECIFICATIONS
2" DEEP, 3/16" WIDE
A1
PLAIN CEMENT CONCRETE CURB GUTTER
NOT TO SCALE
TYPICAL
CROSS SECTION
2" DEEP, 3/16" WIDE
CONTRACTION JOINT
PLAIN CEMENT
CONCRETE CURB
CONTRACTION JOINT
(CONTINUOUS THRU
CURB AND GUTTER)
C
O
N
T
R
A
C
T
I
I
A
C
I
N
G
N
1/2" MINIMUM
7"1"
8"2'-0"
1/4" RADIUS
1/4" RADIUS
3/4" RADIUS
GUTTER WIDTH
* 8.0% (1"/FT) MIN.
PCC CONCRETE
PER SPECIFICATIONS
* SLOPE
1/4" RADIUS
A6
VERTICAL CURB OVER AVB FOUNDATION
NOT TO SCALE
DETAIL A
CONTRACTION JOINT
PLAIN CEMENT
CONCRETE CURB
7"1"
8"
1/4" RADIUS
TOPSOIL OR SIDEWALK
AS REQUIRED BY
LOCATION
3/4" RADIUS
C
O
N
T
R
A
C
T
I
I
A
C
I
N
G
2" DEEP, 3/16" WIDE
N
CONTRACTION JOINT,
SEE DETAIL A.
PCC CONCRETE PER SPECIFICATIONS
M
I N
AVB FOUNDATION
#4 x 12" TIE BAR -
SEE NOTES 1 AND 2
DETAIL B
#4 x 12" TIE BARS
2"
3"
NOTES:
1. PLACE TIE BARS AT 18" TO 24" ON CENTER LONGITUDINAL SPACING BETWEEN JOINTS IN
EXISTING PAVEMENT. TIE BARS SHALL BE LOCATED 3" MINIMUM FROM TOP OF CURB, BACK OF
CURB AND ANY CARRIAGE BOLTS IN AVB FOUNDATION.
2. DRILL 3/4" HOLES FOR TIE BARS AND EPOXY TO NEW PAVEMENT. EPOXY-RESIN SHALL BE TWO
COMPONENT EPOXY-RESIN MATERIAL FORMULATED TO MEET THE REQUIREMENTS OF ASTM
C881/C881M, TYPE III, GRADE AND CLASS AS APPROVED, FOR USE IN BOND COAT APPLICATIONS
AND AS A COMPONENT OF EPOXY-RESIN CONCRETE OR MORTAR. MIX EPOXY-RESIN GROUT
COMPONENTS IN THE PROPORTIONS RECOMMENDED BY THE MANUFACTURER. CONDITION THE
COMPONENTS TO 20 TO 30 DEGREES C 70 TO 85 DEGREES F FOR 48 HOURS PRIOR TO MIXING.
MIX THE TWO EPOXY COMPONENTS WITH A POWER-DRIVEN, EXPLOSION-PROOF STIRRING
DEVICE IN A METAL OR POLYETHYLENE CONTAINER HAVING A HEMISPHERICAL BOTTOM. ADD
THE CURING-AGENT COMPONENT GRADUALLY TO THE EPOXY-RESIN COMPONENT WITH
CONSTANT STIRRING UNTIL A UNIFORM MIXTURE IS OBTAINED. STIR SUCH THAT THE AMOUNT
OF ENTRAINED AIR IS A MINIMUM. CURE EPOXY PER MANUFACTURER INSTRUCTIONS.
CARRIAGE BOLT
S O
L I C
I T
A T
I O
N
N
O
D E
S I G
N E
D
B
Y
D E
S C
R I P
T I O
N
M A
R K
S I Z
E
S U
B M
I T
T E
D
B
Y
D A
T E
C O
N T
R A
C H
E C
K E
D
B
Y
D R
A W
N
B
Y
I S
S U
E
D
A T
E
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
US Army Corps of Engineers
U
M
Y
C
O R
F
E
N G
I N
E E
R S
H D
R
E
N G
I N
E E
R I N
G
I N
C
T
H
S
T R
E E
T
O
M A
H A
N
E
B A
L T
I M
O R
E
D
I S
T R
I C
T
O C
T
A N
S I
D
F O
D I A
N T
O W
N
G
A P
P
A
M A
C
E S
S
C
O N
T R
L
I N
T
P R
O J E
FINAL DESIGN
J B
C S
C H
J S
F
C I V
L
D
E T
A I L
S
1C-503 c:\pwworking\central01\d0478269\10078599-FIGW-1C-501.dwg
31 October 2019 11:46 AM Brandt, Jill C.
SECTION 13 34 23
PREENGINEERED GUARD BOOTH STRUCTURES
11/11
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.
AMERICAN SOCIETY OF CIVIL ENGINEERS (ASCE)
ASCE 7 (2017) Minimum Design Loads for Buildings and Other Structures
ASTM INTERNATIONAL (ASTM)
ASTM A653/A653M (2017) Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process
ASTM A924/A924M (2017a) Standard Specification for General Requirements for Steel Sheet, Metallic-Coated by the Hot-Dip Process
ASTM C1036 (2016) Standard Specification for Flat Glass
ASTM C592 (2016) Standard Specification for Mineral Fiber Blanket Insulation and Blanket-Type Pipe Insulation (Metal-Mesh Covered) (Industrial Type)
ASTM D2244 (2016) Standard Practice for Calculation of Color Tolerances and Color Differences from Instrumentally Measured Color Coordinates
ASTM D4214 (2007; R 2015) Standard Test Method for Evaluating the Degree of Chalking of Exterior Paint Films
ASTM E84 (2018b) Standard Test Method for Surface Burning Characteristics of Building Materials
BUILDERS HARDWARE MANUFACTURERS ASSOCIATION (BHMA)
ANSI/BHMA A156.115 (2016) Hardware Preparation in Steel Doors and Steel Frames
ANSI/BHMA A156.1 (2016) Butts and Hinges
ANSI/BHMA A156.2 (2017) Bored and Preassembled Locks and
SECTION 13 34 23 Page 1
Latches
ANSI/BHMA A156.4 (2013) Door Controls - Closers
ANSI/BHMA A156.8 (2015) Door Controls - Overhead Stops and Holders
ANSI/BHMA A156.18 (2016) Materials and Finishes
METAL BUILDING MANUFACTURERS ASSOCIATION (MBMA)
MBMA MBSM (2012) Metal Building Systems Manual
STEEL DOOR INSTITUTE (SDI/DOOR)
SDI/DOOR A250.8 (2003; R2008) Recommended Specifications for Standard Steel Doors and Frames
UNDERWRITERS LABORATORIES (UL)
UL 752 (2005; Reprint Dec 2015) Standard for Bullet-Resisting Equipment
1.2 GENERAL REQUIREMENTS
This specification covers pre-engineered guard booths associated with the ID Check Area Canopy. See the contract drawings for more information regarding the layout and configuration of these structures. The guard booths in the ID check area shall be similar or equal to the Standard 4'-0" x 10'-0" bullet resistant guard booth, as shown on the drawings.
Manufacturer's Instructions shall be submitted by the Contracting Officer for Pre-Engineered Guard Booth Structures, indicating the recommended installation methods and sequence.
Manufacturer's Standard Color Charts and Color Panels shall be submitted by the Contacting Officer for Exterior Panels, Interior Panels, Accessories and Trim.
Design analysis and calculations for Pre-Engineered Guard Booth Structures, and Metal Roofing and Siding Panels shall be prepared and certified by a registered professional structural engineer.
Certificates shall be submitted for Materials, Equipment and Accessories showing conformance with the referenced standards contained in this section.
1.2.1 Dimensions
Guard Booth dimensions shall be as standard with manufacturer, not less than those indicated, but exceeding the indicated dimensions only by the amount of the closest standard size thereto, subject to approval by the Contracting Officer, and at no additional cost to the government. Any approved changes in dimensions from those shown on the contract drawings shall be carefully coordinated with the other trades.
1.3 DESIGN CRITERIA
Use MBMA MBSM except as modified herein and except that ASCE 7 will govern
SECTION 13 34 23 Page 2 for for loading combinations and methodology for development of wind, snow, live, and seismic loads. Design for each material shall be as specified by the Design Authority as listed in MBMA MBSM. Deflection of metal roofing and siding panels shall not exceed 1/180 of the span on single span loading under the total live and wind load. See contract drawings for Guard Booth foundation details.
1.4 SUBMITTALS
Government approval is required for submittals with a "G" designation;
submittals not having a "G" designation are for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:
SD-01 Preconstruction Submittals
Manufacturer's Instructions
SD-02 Shop Drawings
Fabrication drawings shall be submitted for the following items:
Installation drawings shall also be submitted for the following items and shall be in accordance with the paragraph entitled, "Assembly and Erection," of this section.
Roofing And Siding Panels; G, AO
Structure; G, AO
Accessories
Interior Panels; G, AO
Windows; G, AO
Steel Doors And Frames; G, AO
Louvers
Gutters And Downspouts
Base Reactions; G, AE
Anchorage To Foundation; G, AE
SD-03 Product Data
Manufacturer's catalog data shall be submitted for the following items, including accessories and installation materials.
Structure; G, AO
Roofing And Siding; G, AO
Finish; G, AO
SECTION 13 34 23 Page 3
Accessories; G, AO
Interior Panels; G, AO
Insulating Materials
Windows
Steel Doors And Frames; G, AO
Weather-Stripping
Glass And Glazing
Louvers
Gutters And Downspouts
SD-04 Samples
Contractor shall provide the following samples:
Manufacturer's Standard Color Charts shall be submitted in accordance with paragraph entitled, "General Requirements", of this section
Color Panels; G, AO Three pieces, 4 by 4 inches, to indicate maximum color range
Exterior Panels; G, AO
Interior Panels; G, AO
Accessories; G, AO
Trim; G, AO
Roofing And Siding: One piece, 9 inches by width of panel
Insulating Materials: One piece 8 by 11 inches
SD-05 Design Data
Design analysis and calculations for the following items shall be in accordance with the paragraph entitled, "General Requirements," of this section.
Pre-Engineered Guard Booth Structures; G, AO
SD-07 Certificates
Certificates shall be submitted for the following in accordance with paragraph entitled, "General Requirements", of this section
Materials; G, AO
Equipment
SECTION 13 34 23 Page 4
Accessories; G, AO
SD-11 Closeout Submittals
Manufacturer's Warranty
Contractor's Warranty for Installation
1.5 Manufacturer's Warranty
1.5.1 Building System Warranty
Furnish manufacturer's no-dollar-limit warranty for the metal building system. The warranty period is to be no less than 1 year from the date of acceptance of the work and be issued directly to the Government. The warranty must provide that if within the warranty period, the metal building system shows evidence of deterioration resulting from defective materials and/or workmanship, correcting of any defects is the responsibility of the metal building system manufacturer. Repairs that become necessary because of defective materials and workmanship while metal building system is under warranty are to be performed within 32 hours after notification, unless additional time is approved by the Contracting Officer. Failure to perform repairs within 32 hours of notification will constitute grounds for having emergency repairs performed by others and will not void the warranty.
1.5.2 Roof System Weather-Tightness Warranty
Furnish manufacturer's no-dollar-limit warranty for the metal panel system. The warranty period is to be no less than 1 year from the date of acceptance of the work and be issued directly to the Government.
The warranty is to provide that if within the warranty period the roof panel system shows evidence of corrosion, perforation, rupture, lost of weather-tightness or excess weathering due to deterioration of the panel system resulting from defective materials and correction of the defective workmanship is to be the responsibility of the metal building system manufacturer.
Repairs that become necessary because of defective materials and workmanship while roof panel system is under warranty are to be performed within 24 hours after notification, unless additional time is approved by the Contracting Officer. Failure to perform repairs within 24 hours of notification will constitute grounds for having emergency repairs performed by others and not void the warranty. Immediate follow-up and completion of permanent repairs must be performed within 7 days from date of notification.
1.5.3 Roof Finish Warranty
Furnish manufacturer's no-dollar-limit warranty for the metal panel system. The warranty period is to be no less than 5 years from the date of acceptance of the work and be issued directly to the Government.
The warranty is to provide that if within the warranty period the metal panel system shows evidence of checking, delaminating cracking, peeling, chalk in excess of a numerical rating of eight, as determined by ASTM D4214 test procedures; or change colors in excess of five CIE or Hunter units in accordance with ASTM D2244 or excess weathering due to deterioration of
SECTION 13 34 23 Page 5 the panel system resulting from defective materials and finish or correction of the defective workmanship is to be the responsibility of the metal building system manufacturer.
Liability under this warranty is exclusively limited to replacing the defective coated materials.
Repairs that become necessary because of defective materials and workmanship while roof and wall panel system is under warranty are to be performed within 32 hours after notification, unless additional time is approved by the Contracting Officer. Failure to perform repairs within 32 hours of notification will constitute grounds for having emergency repairs performed by others and not void the warranty.
PART 2 PRODUCTS
2.1 STRUCTURE
Pre-engineered steel guard booth shall be a single unit welded steel construction with galvannealed steel panels on the exterior and tubing with steel panels on the interior.
2.1.1 Structural Loads
Loads to the pre-engineered steel guard booth shall be determined based on the following parameters. Loads to be determined and applied in accordance with the requirements and methodology in ASCE 7. Base Reactions resulting from these applied structural loads are to be documented and submitted.
These base reactions are to be used in the design of the anchorage to foundation.
2.1.1.1 Floor Live Load
Pre-engineered steel guard booth floor shall be designed a minimum floor live load of 75 psf.
2.1.1.2 Minimum Roof Live Load
Pre-engineered steel guard booth roof shall be designed for a minimum construction and maintenance uniform live load of 20 psf.In addition to uniform live load, a minimum concentrated load of 300 pounds shall be used to simulate a construction load on roof panels. The concentrated load shall be applied at the midspan and shall be resisted by a single metal roof panel assumed to be acting as a beam. The undeformed shape of the panel shall be used to determine the section properties.
2.1.1.3 Roof Snow Load
Pre-engineered steel guard booth roof shall be designed for a roof snow based on the following parameters:
Ground Snow Load: Pg = 35 psf.
Exposure Factor: Ce = 1.0 Thermal Factor: Ct= 1.1 Importance Factor: I = 1.0 Snow Density: 18.55 pcf Effects of sliding snow, drifting snow, and rain on snow surcharge shall be included as required.
SECTION 13 34 23 Page 6
2.1.1.4 Wind Loads
Pre-engineered steel guard booth walls and roof shall be designed for wind loads based on the following parameters:
Basic Wind Speed: V = 115 mph Importance Factor: I = 1.0 Exposure Category: C Topographic Factor: Kzt = 1.0 Internal Pressure Coefficients: GCpi = +/- 0.55 Design shall performed with due regard for components and cladding wind loads.
2.1.1.5 Seismic Loads
Pre-engineered steel guard booth structure shall be designed for seismic loads based on the following parameters:
Short Period Spectral Response Acceleration: Ss = 0.16g 1 Second Spectral Response Acceleration: S1 = 0.06g Site Class: B Occupancy Category: II Importance Factor: I =1.0 Seismic Design Category: A Response Factor, R: 3, minimum
2.2 ROOFING AND SIDING
Panels shall conform to ASTM A653/A653M , Grade A, and be ballistic rated in accordance UL 752 to Level III (44 magnum round). Zinc coating shall conform to ASTM A653/A653M and ASTM A924/A924M . Rood seams shall be continuously welded, caulked and waterproofed.
Metal fascia shall be of the same material as the roofing and siding and not less than 26-gage.
Provide lifting rings welded to roof for onsite lifting of the unit.
2.3 FINISH
All steel surfaces shall be painted with a rust inhibitive epoxy primer.
All exposed exterior steel surfaces shall be painted with an industrial acrylic enamel paint.
2.4 ACCESSORIES
Sheet-metal accessories shall be formed of material of the same type and finish as roofing and siding panels and shall be not less than 26-gage.
2.5 INTERIOR PANELS
Panels shall conform to ASTM A653/A653M , grade with an industrial acrylic epoxy finish standard with the manufacturer.
SECTION 13 34 23 Page 7
2.6 INSULATING MATERIALS
2.6.1 Flame Spread
Insulation shall have a flame spread not in excess of 25 and a smoke developed rating not in excess of 50 when tested in accordance with
ASTM E84.
2.6.2 Rigid Board
Board insulation shall conform to ASTM C592. Roof structure shall have an R=17.4, walls R=10.
2.7 WINDOWS
Windows shall be steel and shall be ballistic rated in accordance UL 752 to Level III (44 magnum round) requirement. Windows shall be glazed with bullet resistant glass.
2.8 STEEL DOORS AND FRAMES
Doors and frames shall conform to SDI/DOOR A250.8 .
Door shall be steel and ballistic rated in accordance UL 752 to Level III (44 magnum round).
Sliding steel door suspended from a top mounted track. The door shall suspend from heavy steel axles, all steel ball bearing, and steel wheels.
Tracks shall be heavy duty steel standard to the manufacturer.
Swing doors shall be commercial heavy duty hollow metal 1 3/8" thick with bored lockset, heavy duty hydraulic closer and hinges.
Preparation for hardware shall be in accordance with ANSI/BHMA A156.115 and the manufacturer's standards.
2.9 FINISH HARDWARE
Hardware shall manufacturer's standard and conform to ANSI/BHMA A156.1 , ANSI/BHMA A156.2 , ANSI/BHMA A156.4 , ANSI/BHMA A156.8 .
Finishes shall conform to ANSI/BHMA A156.18 .
2.10 WEATHER-STRIPPING
Weatherstripping for the heads, jambs, and sills of exterior doors shall be the manufacturer's standard.
2.11 GLASS AND GLAZING
Glass shall conform to ASTM C1036. Glass shall be ballistic rated for Level III (.44 Magnum)ammunition.
2.12 LOUVERS
Louvers shall be the manufacturer's standard for galvanized bullet resistant steel conforming to ASTM A653/A653M . Zinc coating shall be in accordance with ASTM A653/A653M and ASTM A924/A924M .
SECTION 13 34 23 Page 8
2.13 GUTTERS AND DOWNSPOUTS
Gutters and downspouts shall conform to ASTM A653/A653M . Zinc coating shall be in accordance with ASTM A653/A653M and ASTM A924/A924M . Material shall be not less than 26-gage.
2.14 Miscellaneous
Base and floor shall be 4 inches in height for outside use. Floors shall be 12-gauge galvanized steel, 4-way tread plate. Four 1/4 inch steel angle clips with pre-drilled holes provided to secure the building.
Anchors shall be galvanized or stainless steel.
Work counter located across the with of the unit shall be painted steel.
A single steel storage drawer shall be provided in the center of the counter.
PART 3 EXECUTION
3.1 ASSEMBLY AND ERECTION
Assembly and erection shall be on a prepared foundation in accordance with the manufacturer's instructions and recommendations.
3.2 WARRANTY
3.2.1 MANUFACTURER'S WARRANTY
Submit all manufacturers' signed warranties to Contracting Officer prior to final commissioning and acceptance.
3.2.2 CONTRACTOR'S WARRANTY for INSTALLATION
Submit contractor's warranty for installation to the Contracting Officer prior to final commissioning and acceptance.
3.2.3 CONTRACTOR'S FIVE (5) YEAR NO PENAL SUM WARRANTY
SECTION 13 34 23 Page 9
CONTRACTOR'S FIVE (5) YEAR NO PENAL SUM WARRANTY
FOR
METAL BUILDING SYSTEM
FACILITY DESCRIPTION:________________________________________________________
BUILDING NUMBER:_____________________________________________________________
CORPS OF ENGINEERS CONTRACT NUMBER:__________________________________________
CONTRACTOR
CONTRACTOR:__________________________________________________________________
ADDRESS:_____________________________________________________________________
POINT OF CONTACT:____________________________________________________________
TELEPHONE NUMBER:____________________________________________________________
OWNER
OWNER:_______________________________________________________________________
ADDRESS:_____________________________________________________________________
POINT OF CONTACT:____________________________________________________________
TELEPHONE NUMBER:____________________________________________________________
CONSTRUCTION AGENT
CONSTRUCTION AGENT:__________________________________________________________
ADDRESS:_____________________________________________________________________
POINT OF CONTACT:____________________________________________________________
TELEPHONE…