This file is a photographic documentation of existing conditions for an HVAC system replacement project at Buffumville Lake in Charlton, Massachusetts. The photographs, prepared by the U.S. Army Corps of Engineers - New England District, document the current state of heating, ventilation, and air conditioning equipment that is scheduled for replacement under solicitation W912WJ26QA095. The images include existing fan coil units (FCU-1 at 3-ton capacity and FCU-2 at 4-ton capacity), two boilers (B-1 and B-2) serving office/shop and living quarters buildings respectively, two condensing units (CU-1 and CU-2), radiant fin tube heating systems, hydronic unit heaters, radiant floor piping with zone controls, and the attic and plenum spaces where equipment is located. Equipment nameplates and manufacturer specifications are documented for reference purposes.
The photographs serve as baseline documentation for a small business set-aside project with an estimated construction value between $100,000 and $250,000. The work scope involves removing and replacing aging HVAC systems with new heat pump systems, ceiling-hung electric unit heaters for auxiliary heating, programmable thermostat controls, an energy recovery ventilator for air ventilation, cleaning of existing finned tube systems, insulation of heating and domestic water piping, and abandonment of non-functional radiant slab piping. The project is governed by NAICS code 238220 with a small business size standard of $19 million, and all vendors must maintain active SAM.GOV registration at the time of proposal submission.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Amendment W912WJ26QA095-0002.pdf | ||
| Amendment W912WJ26QA095-0001.pdf | ||
| Solicitation W912WJ26QA095.pdf | ||
| Attachments Drawings 26QA095.pdf | ||
| Solicitation Survey 26QA095.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
March 2026
PHOTOGRAPHS
EXISTING CONDITION PHOTOS
M-1: Rear of Three Buildings With CU-1 (Left) And CU-2 (Right) In View
M-2: Original Living Quarter Building With Infill Addition Connection Shown
U.S. Army Corps New England District
M-3: FCU-1 (3-Ton) System Above Ceiling
M-4: FCU-1 (3-Ton) System Nameplate
M-5: FCU-2 (4-Ton) System Above Ceiling
M-6: FCU-2 (4-Ton) System Nameplate
M-7: Attic Space Above Original Living Quarters Building
M-8: Plenum Space Above New Addition Infill Portion
M-9: Existing Radiant Fin Tube Typical in Two Existing Buildings
M-10: Boiler 1 (B-1) Located in Existing Office/Shop Building
M-11: Hydronic Unit Heater (Typical) Located in Shop Spaces
M-12: Boiler 2 (B-2) Located in Basement of Existing Living Quarters
M-13: Boiler 2 (B-2) Equipment Nameplate
M-14: Radiant Floor Piping/Zone Control Located in Existing Living Quarters Basement
M-15: Condensing Unit 1 (CU-1)
M-16: Condensing Unit 1 (CU-1) Equipment Nameplate
M-17: Condensing Unit 2 (CU-2)
M-18: Condensing Unit 2 (CU-2) Equipment Nameplate
| COVER |
| BIDDING SCHEDULE |
| STATEMENT OF WORK |
| A. General Description of the Work to be Performed |
| B. Measurement and Payment |
| C. General Project Requirements |
| D. Safety |
| E. General and Administrative Submittals Required |
| F. Technical Submittals Required |
| G. Technical Requirements |
| H. Delivery, Handling and Storage |
| I. Material Warranties |
| J. Coordination |
| K. References |
| SUBMITTAL FORM 4025 |
| ENG FORM 3394 (AUG 2021) MISHAP NOTIFICATION AND INVENTIGATION |
| DRAWINGS |
| PHOTOGRAPHS |