Attachment Z - GEND6AG23 Generator Technical Specifications _.pdf

PDF 36 KB Posted

Attached to
Generator Maintenance at the Administrations District 6 Facilities in Alleghany, Garrett, and Washington Counties
Solicitation number
BPM017952
Issued by
Allegany County, Garrett County, Washington County, Maryland

About this file

This document appears to be an attachment containing technical specifications for generators located at various Maryland State Highway Administration (MD SHA) District 6 facilities in Allegany, Garrett, and Washington Counties. The attachment provides detailed information on 12 generator units, including their engine and generator manufacturer, model, serial number, phase, voltage, amperage, fuel type and tank size, as well as service history, filter and part numbers, and other maintenance-related details.

The related state and local contract opportunity is for Generator Maintenance at the MD SHA District 6 Facilities in these three counties. The contract appears to cover routine maintenance and servicing of the generators described in the attachment, though the specific scope of work is not provided. No further details are given regarding the contract term, award process, or pricing.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

MD SHA - OOM D6 Standby Generator & Maintenance List 2019/2020 Engine Engine Eng / Gen Generator Generator Generator Tran. Sw. Tran. Sw. Tran. Sw. Engine Engine Service Oil Type/ Qty Coolant

Capacity Battery

Hrs/Date Horse Power Mfg Date. Make Serv.Date

Dist.# Bldg. Loc. Generator Mfg Date. Manufactur. Eng.Ser. # Gen. Manuf. Phase Amps Type Model / No. Location Fuel Type Tank Size Contracts Fuel Filter Oil Filter H20 Filter Belt Name. Bat. CCA Air Filter

County Gen. Loc. Y / N Serv.Date Model # Gen. Ser. # Model No. Volts / kw Serv.Date Volt./Amp Serial No. Phase UST/AST Warranty Part#/Qty. Part#/Qty. Part# Part #/Qty. Part #/Qty. Part#/Qty.

566 hrs

11.2012 550 HP Unknown Kohler Unknown

15w-40 / 38 Qts 24 Qts Deka

#6 D6 Office La Vale Y 4/92?

Detroit Diesel Series

#7A42758 Kohler 3 694 amps Auto. #K16834180

D6 Bldg.

Basement Diesel 500 Gal. NO Luber Finer Luber Finer N/A Kohler 1000 cca Fletguard

Allegany Bldg Side- Outside

Eng.#

06AO471884 03.08..16

#10637305 Spec-A- 272650

#358562 #200ROZD8

240 volt 200 kw 03.08.16 208 volt

800amp #K-57057 3 Phase AST Subbase NO #LFP816FN

#LFP815FN #LFP911 x1 N/A #343623DF x3 #20-0367 x1 #1231PMF #AF 263 x1

296 on

7.22.16 240 HP Unknown Generac Unknown 15W40

20.7 Qts. 7.5 Gal. EXIDE WIX

#6 La Vale Shop Y Apr-97 New Holland #2033426 Generac 3 520 amp Auto. 97A01120-W Main Office Electric room Diesel 265 Gal. YES NAPA NAPA N/A Tri Power 1000 CCA ECO

SERIES

Allegany Gen. Room- Inside 11/13/2015 Unknown #2033426 #97A-

01120 S 208 volt 150kw 09/02/2015 208 volt

600 amp 38754 3 phase AST Subbase NO #3166 x2 #1775 x1 N/A Vextra AX55 x2

#COM-4D-P

x1 #546759 x1

17 hrs

6.14.16 674 HP 2014

Kohler Decission

Maker 1200 N/A 15W40

51 Qts. 16 Gal. Ameristart

#6 Keysers Ridge Shop Y Sep-14 Volvo Penta #D16

082563C3A Kohler 3 902 amp Auto. See Note! Generator Room Diesel 500 gal. YES Volvo ? ? Volvo 1000 cca Donaldson

Garrett Gen. Room- Inside

New Installtion 2015/16.

Family#

EVPXL16

IACW

#SGM32CF4

W

#600REOZV

B

480 volt 600 kw N/A

480 volts 400/800 amps See Note! 3 Phase AST -

Subbase YES #20998367 x1 ? ? #3883978 x1 #C31A-PF #FRG18003 1 x2

641/ 9.17.15 165 HP Unknown Kohler Unknown 9.0 Qt. 10 Qt. CarQuest

#6 Oakland Shop Y 03.20.1996 John Deere #CD6059T2 46727

Kohler Power

Systems 3 278 amp Auto. #S340 Elect. Room

Main Bldg Diesel 275 Gal. NO NAPA NAPA N/A Unknown 930 CCA Donaldson

Garrett Gen. Room- Inside Unknown #6059TF #374339 #80ROZJ81 208 volt 80 kw Unknown 208 volt 400 amp #K61892 3 Phase AST-

Subbase NO #3548 x1 #1243 x1 N/A ? X2 #2474-75 x1

#P133765 x1

247hr

9.18.15 465 P Unknown GE Zenith

Controls Unknown 15W40

10.2 gal 5.5 gal. Exide

#6 Hagerstown Shop Y Jan-85 Cummins #54638 Katolight 3 271 amp Auto. #ZTS-41EC-

7AAA4C

Generator

Room Diesel 300 gal NO Luber Finer Fleetguard Luber Finer Cummins 1000 CCA Vortox

Wahington Gen. Room- Inside 04.09.09 #NTA-855

G2 #91898-C-

34614 #D180FRZ4 480 volt 1800kw 04.09.09 480 volt

400 amp #54638 3 Phase AST NO #LFF5002 x2 #LF9009 x1 #LFW-2055 x1 #217638 x1 #201927 x3 #4D x2 #AN133C x1 1104 hrs /

9.17.15 92 HP Unknown Kohler Unknown 15w-40/

12.0 L. 16.5 L. NAPA

#6 I-68 Sideling Hill Resr Area Y Unknown John Deere #T04039T33

6164 Kohler 3 90 amp Auto. #60ROZJ71 At generator Diesel 150 Gal.? NO N/A NAPA N/A Kohler 950 CCA Fletguard

Wahington Fenced Area- Outside 01.10.14 4039TF001 #277257 #60R0ZJ71 480 volt

60kw 01/10/2014 480 volt 104 amp #277257 3Phase AST-

Subbase NO N/A #1243 x1 N/A 223640 x1 #7237 x1 AF-1913 x1

#6 I-68 Youghiogheny Overlook.

No Generator!!

Garrett NONE

Engine Engine Eng / Gen Generator Generator Generator Tran. Sw. Tran. Sw. Tran. Sw. Engine Engine Service Oil Type/ Qty Coolant Capacity Battery

Hrs/Date Horse Power Mfg Date. Make Serv.Date

Dist.# Bldg. Loc. Generator Mfg Date. Manufactur. Eng.Ser. # Gen. Manuf. Phase Amps Type Model / No. Location Fuel Type Tank Size Contracts Fuel Filter Oil Filter H20 Filter Belt Name. Bat. CCA Air Filter

County Gen. Loc. Y / N Serv.Date Model # Gen. Ser. # Model No. Volts / kw Serv.Date Volt./Amp Serial No. Phase UST/AST Warranty Part#/Qty. Part#/Qty. Part# Part #/Qty. Part #/Qty. Part#/Qty.

D6