This document includes an attachment reviewing well inspection details and a federal contract solicitation. The solicitation is for an Indefinite Delivery Indefinite Quantity Multiple Award Contract for environmental remediation services in the Hampton Roads, Virginia area. Services include operation and maintenance of remedial systems, long-term management, monitoring, and treatment of contaminants. The contract value has a maximum of $30 million over multiple years. Task orders will range from $50,000 to $250,000. The solicitation is designated as a 100% small business set-aside for firms in the Eastern United States. Responses are due by the date listed on the solicitation. The Naval Facilities Engineering Command Mid-Atlantic will award up to five basic contracts for services to commence upon award.

View the file

Other files

Show all 18

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet1

Well IDGauging DateTime of CollectionDepth to Water (ft below TOC)Depth to Product (ft below TOC)Depth to Bottom (ft below TOC)COMMENTSRPM NotesBolts requiredBollards/Casings to ReplaceJ-plugs to replacePaintLocksHinges
B-MW9A12/11/2012:485.75-26.625316923103
B-MW9B12/11/2012:526.3565.14
B-MW8A12/11/209:155.6525.63missing bolts3
B-MW8B12/11/209:165.8766.48missing j-plug1
A-GW-312/11/2012:468.1145.47missing bollardsNo need for bollards
A-GW-212/11/2010:316.26-24.811 leaning bollard, missing j-plug1
A-MW11A12/11/2010:338.93-26.87light rust1
A-MW11B12/11/2010:548.69-64.53light rust1
A2-MW2912/11/2010:576.51-22.06peeling paint1
A-MW1212/11/2011:057.8-21.41rust1
A-MW19B12/11/2011:009.09-66.73overgrown w/vegetation, rustclear vegetation1
A2-MW3012/11/2011:1913.47-22.73overgrown w/vegetation, paint peelingclear vegetation1
A-MW1B12/11/2011:409.02-54.74overgrown w/vegetation, paint peelingclear vegetation1
B-15WA12/11/2011:384.39-25.32overgrown w/vegetation, no lockclear vegetation1
B-15WB12/11/2011:365.23-127.11overgrown w/vegetation, no lock, no bollardsclear vegetation, no need for bollards due to location1
A1-MW24B12/11/2014:223.51-67.34no lock1
A1-MW4A12/11/2010:546.39-22.14rust1
A1-MW4B12/11/2010:477.80-59.8rust1
B-9W12/11/2012:408.1523.97peeling paint1
B-11W12/11/2012:2010.13-25.49missing j-plug, well extends above casingcut PVC down to fit in casing1
B-13W12/11/2012:248.52-25.14light rust1
B-16W12/11/2012:288.46-25.93overgrown w/vegetation, light rustclear vegetation1
B-17W12/11/2012:307.56-17.13overgrown w/vegetation, 1 broken bollardclear vegetation1
B-20SS12/11/2012:326.24-27.33light rust1
B-20W12/11/2012:333.74-23.781 broken bollard, well extends above casingreplace casing or cut PVC down to fit in casing1
B-1W12/11/208:576.32-24.63
B-4W12/11/209:517.06-25.33missing j-plug1
B-7W12/11/2010:007.21-24.83light rust1
B-5W12/11/209:545.38-21.08missing j-plug1
A1-MW2112/11/209:245.27-27.47cracked pad/bollards, no j-plug, no lock311
A1-MW2012/11/2010:207.81-31.74missing 2 bollards2
A1-MW9A12/11/2010:274.79-24.57peeling paint1
A1-MW9B12/11/2010:294.12-61.99peeling paint1
A1-MW9C12/11/2010:257.91-116.63missing bollard, no lock11
A1-MW8A12/11/2010:364.78-25.11no lock, rust11
A1-MW8B12/11/2010:384.83-63.23rust1
A1-MW25A12/11/2010:075.37-21.05paint peeling1
A1-MW25B12/11/2010:064.72-67.61paint peeling, leaning bollard11
A1-MW6A12/11/2010:125.45-35.12overgrown w/vegetation, light rustclear vegetation1
A1-MW6B12/11/2010:116.63-59.71overgrown w/vegetation, light rustclear vegetation1
A-MW512/11/208:222.2-26.87missing j-plug, broken hinge, downed bollards311
A-MW712/11/2014:452.93-21.81broken hinge1
A-MW31B12/11/2013:072.60-66.71missing 3 bolts3
A-MW13B12/11/2013:105.75-64.07missing bolts, damaged well casing31
A1-MW26B12/11/2015:136.64-66.5light rust1
A1-EW1B12/11/2015:156.9266.5
A1-MW27B12/11/2015:127.4966.95no lock, 2 bollards down21
A1-MW10A12/11/2015:043.4121.51no lock1
A1-MW10B12/11/2015:083.78-68.27no lock1
A-MW-30AR12/11/208:354.15-12.54
A-MW-30BR12/11/208:403.88-70.211 bolt broken in well casing tab1
A-MW18A12/11/208:506.61-14.9
A-MW18B12/11/208:454.75-77.76
A2-MW32AR12/11/208:106.39-16.3
A2-MW32BR12/11/208:157.35-58.55
B-MW3812/11/2010:100.97-27.3missing 1 bolt1
B-MW3912/11/2010:044.13-24.87
B-MW37A12/11/2010:011.07-13.56missing 1 bolt, 2 bolts stripped3
B-MW1612/11/209:452-15missing 2 bolts2
B-MW15A12/11/209:501.24-14.95missing 2 bolts2
B-MW15B12/11/209:56NA-NAobstructed by wiring/pump mechanism
B-MW35A12/11/209:532.47-13.093 bolts stripped3
B-MW29R12/11/2010:253.14-14.19missing 1 bolt, 1 broken tab, 2 stripped bolts3
B-MW22A12/11/2010:352.48-16.303 bolts stripped3
B-MW22B12/11/2010:393.33-63.8
B-MW1412/11/2010:443.50-15.04
B-MW4412/11/2010:495.34-11.68rubber lid over PVC riser, no well casingFixed on 1/25/20221111
B-MW112/11/2010:565.78-24.50
B-MW4512/11/2010:532.9611.85
B-GW-612/11/2011:205.71-25.81
B-MW2A12/11/2011:243.65-22.43
B-MW2B12/11/2011:354.49-60.63missing 1 bolt1
B-MW2C12/11/2011:304.48-124.35
B-MW18A12/11/2011:405.02-16.2
B-MW1012/11/2012:393.02-22.45
B-MW1312/11/2011:553.53-13.84missing 2 bolts2
B-MW1212/11/2012:072.7-13.32missing 1 bolt1
B-MW11A12/11/2012:193.35-20.46
B-MW11B12/11/2012:163.71-65.38missing 2 bolts2
B-MW2012/11/2012:102.76-24.7missing 2 bolts2
B-MW3A12/11/2012:303.02-20.22
B-MW3B12/11/2012:334.39-59.5missing j-plug1
B-MW33A12/11/2012:274.09-12.84missing 3 bolts3
B-MW33B12/11/2012:225.02-64.01missing 3 bolts3
B-MW3112/11/2012:363.05-12.36missing 3 bolts3
B-MW34A12/11/2012:564.14-16.231 missing bolt, 2 bolts stripped3
B-MW34B12/11/2013:015.9-62.643 bolts stripped3
B-MW3212/11/2012:424.0412.923 bolts stripped3