Attachment J02 Drawings.pdf

PDF 34 MB Posted

Attached to
Santa Fe Indian Hospital Pharmacy Renovation
Solicitation number
75H70123R00015
Issued by

About this file

This document provides details for a federal construction solicitation notice seeking offers for the Santa Fe Indian Hospital Pharmacy Renovation project. The project scope involves a two-phased renovation of the existing pharmacy department and relocation of the security office at the Santa Fe Indian Hospital located in Santa Fe, New Mexico. Phase 1 includes removal of existing office furnishings and demolition of the pharmacy department. Phase 2 includes construction and renovation of the pharmacy department. The period of performance is 240 calendar days from notice to proceed. The construction magnitude is estimated between $1,000,000 to $5,000,000. A site visit is scheduled for May 31, 2023 at 10:00 AM MDT. The agency intends to award a single firm fixed price contract evaluated with lowest price technically acceptable criteria. The solicitation will be posted on the website for interested offerors to download.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Attachment J02. Drawings Solicitation Number: 75H70123R00015

10 8 5 4 3 2

P

A

PP

R O

VE

D

A R

C H

IT

EC

TU

R

A L

M

EC

H A

N

IC

A L

EL

EC

TR

IC

A L

PL

U

M B

IN

G

R

EV

D A

TE

B

Y D

ES

C

R

IP

TI

O

N

DWN BY

SHEET OF

PROJECT NUMBER

I N D

AI

N

HEALTH

SERVI C

E

P H S -

NOT FOR C

ONSTRUCTIO

N

KEY PLAN

N.T.S.

D

EP

A R

TM

EN

T O

F H

EA

LT

H

ED

U

C A

TI

O

N , A

N D

W

EL

FA

R

E O

FF

IC

E O

F

FA

C

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

A N

D

PR

O

PE

R

TY

M A

N A

G

EM

EN

T

R

EG

IO

N

A L

O

FF

IC

E

O F

FA

C

IL

IT

IE

S

EN

G

IN

EE

R

IN

G A

N D

C O

N

ST

R U

C

TI

O N

STAMP

DATE

SCALE

CKD BY

D

EM

O

LI

TI

O

N F

LO

O

R P

LA

N

AD-1

KEYED NOTES

GENERAL NOTES LEGEND:

DEMOLITION FLOOR PLAN

A

PP

R O

VE

D

A R

C H

IT

EC

TU

R

A L

M

EC

H A

N

IC

A L

EL

EC

TR

IC

A L

PL

U

M B

IN

G

R

EV

D A

TE

B

Y D

ES

C

R

IP

TI

O

N

DWN BY

SHEET OF

PROJECT NUMBER

I N D

AI

N

HEALTH

SERVI C

E

P H S -

NOT FOR C

ONSTRUCTIO

N

KEY PLAN

N.T.S.

D

EP

A R

TM

EN

T O

F H

EA

LT

H

ED

U

C A

TI

O

N , A

N D

W

EL

FA

R

E O

FF

IC

E O

F

FA

C

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

A N

D

PR

O

PE

R

TY

M A

N A

G

EM

EN

T

R

EG

IO

N

A L

O

FF

IC

E

O F

FA

C

IL

IT

IE

S

EN

G

IN

EE

R

IN

G A

N D

C O

N

ST

R U

C

TI

O N

STAMP

DATE

SCALE

CKD BY

R

EN

O

VA

TI

O

N F

LO

O

R P

LA

N

A-1

KEYED NOTES

GENERAL NOTES LEGEND

FLOOR PLAN1

CONCRETE SLAB INFILL2

A

PP

R O

VE

D

A R

C H

IT

EC

TU

R

A L

M

EC

H A

N

IC

A L

EL

EC

TR

IC

A L

PL

U

M B

IN

G

R

EV

D A

TE

B

Y D

ES

C

R

IP

TI

O

N

DWN BY

SHEET OF

PROJECT NUMBER

I N D

AI

N

HEALTH

SERVI C

E

P H S -

NOT FOR C

ONSTRUCTIO

N

KEY PLAN

N.T.S.

D

EP

A R

TM

EN

T O

F H

EA

LT

H

ED

U

C A

TI

O

N , A

N D

W

EL

FA

R

E O

FF

IC

E O

F

FA

C

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

A N

D

PR

O

PE

R

TY

M A

N A

G

EM

EN

T

R

EG

IO

N

A L

O

FF

IC

E

O F

FA

C

IL

IT

IE

S

EN

G

IN

EE

R

IN

G A

N D

C O

N

ST

R U

C

TI

O N

STAMP

DATE

SCALE

CKD BY

R

EN

O

VA

TI

O

N D

IM

EN

SI

O

N F

LO

O

R P

LA

N

A-1.1

KEYED NOTES

GENERAL NOTES

LEGEND

DIMENSION FLOOR PLAN1

10 8 5 410 8 5 410 8 5 4

PPP

3 23 23 2

A

PP

R O

VE

D

A R

C H

IT

EC

TU

R

A L

M

EC

H A

N

IC

A L

EL

EC

TR

IC

A L

PL

U

M B

IN

G

R

EV

D A

TE

B

Y D

ES

C

R

IP

TI

O

N

DWN BY

SHEET OF

PROJECT NUMBER

I N D

AI

N

HEALTH

SERVI C

E

P H S -

KEY PLAN

N.T.S.

D

EP

A R

TM

EN

T O

F H

EA

LT

H

ED

U

C A

TI

O

N , A

N D

W

EL

FA

R

E O

FF

IC

E O

F

FA

C

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

A N

D

PR

O

PE

R

TY

M A

N A

G

EM

EN

T

R

EG

IO

N

A L

O

FF

IC

E

O F

FA

C

IL

IT

IE

S

EN

G

IN

EE

R

IN

G A

N D

C O

N

ST

R U

C

TI

O N

STAMP

DATE

SCALE

CKD BY

KEYED NOTES

GENERAL NOTES

FI

R

E

PR

O

TE

C

TI

O N

N

EW

W O

R K

PL

AN

FP-1

FIRE PROTECTION NEW WORK PLAN1

FIRE PROTECTION NEW WORK PLAN - SECURITY OFFICE2

10 8 5 4

3 2

P

A

PP

R O

VE

D

A R

C H

IT

EC

TU

R

A L

M

EC

H A

N

IC

A L

EL

EC

TR

IC

A L

PL

U

M B

IN

G

R

EV

D A

TE

B

Y D

ES

C

R

IP

TI

O

N

DWN BY

SHEET OF

PROJECT NUMBER

I N D

AI

N

HEALTH

SERVI C

E

P H S -

KEY PLAN

N.T.S.

D

EP

A R

TM

EN

T O

F H

EA

LT

H

ED

U

C A

TI

O

N , A

N D

W

EL

FA

R

E O

FF

IC

E O

F

FA

C

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

A N

D

PR

O

PE

R

TY

M A

N A

G

EM

EN

T

R

EG

IO

N

A L

O

FF

IC

E

O F

FA

C

IL

IT

IE

S

EN

G

IN

EE

R

IN

G A

N D

C O

N

ST

R U

C

TI

O N

STAMP

DATE

SCALE

CKD BY

KEYED NOTES

GENERAL NOTES

PL

U

M

BI

N G

D

EM

O P

LA

N

DP-1

PLUMBING DEMO PLAN - PHARMACY1

PLUMBING DEMO PLAN - SECURITY OFFICE1

10 8 5 410 8 5 4

PP

A

PP

R O

VE

D

A R

C H

IT

EC

TU

R

A L

M

EC

H A

N

IC

A L

EL

EC

TR

IC

A L

PL

U

M B

IN

G

R

EV

D A

TE

B

Y D

ES

C

R

IP

TI

O

N

DWN BY

SHEET OF

PROJECT NUMBER

I N D

AI

N

HEALTH

SERVI C

E

P H S -

KEY PLAN

N.T.S.

D

EP

A R

TM

EN

T O

F H

EA

LT

H

ED

U

C A

TI

O

N , A

N D

W

EL

FA

R

E O

FF

IC

E O

F

FA

C

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

A N

D

PR

O

PE

R

TY

M A

N A

G

EM

EN

T

R

EG

IO

N

A L

O

FF

IC

E

O F

FA

C

IL

IT

IE

S

EN

G

IN

EE

R

IN

G A

N D

C O

N

ST

R U

C

TI

O N

STAMP

DATE

SCALE

CKD BY

KEYED NOTES

GENERAL NOTES

PL

U

M

BI

N G

W

AS

TE

A

N D

V

EN

T N

EW

W

O R

K

PL

AN

P-2

PLUMBING WASTE AND VENT NEW WORK PLAN1

10 8 5 410 8 5 4

PP

A

PP

R O

VE

D

A R

C H

IT

EC

TU

R

A L

M

EC

H A

N

IC

A L

EL

EC

TR

IC

A L

PL

U

M B

IN

G

R

EV

D A

TE

B

Y D

ES

C

R

IP

TI

O

N

DWN BY

SHEET OF

PROJECT NUMBER

I N D

AI

N

HEALTH

SERVI C

E

P H S -

KEY PLAN

N.T.S.

D

EP

A R

TM

EN

T O

F H

EA

LT

H

ED

U

C A

TI

O

N , A

N D

W

EL

FA

R

E O

FF

IC

E O

F

FA

C

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

A N

D

PR

O

PE

R

TY

M A

N A

G

EM

EN

T

R

EG

IO

N

A L

O

FF

IC

E

O F

FA

C

IL

IT

IE

S

EN

G

IN

EE

R

IN

G A

N D

C O

N

ST

R U

C

TI

O N

STAMP

DATE

SCALE

CKD BY

KEYED NOTES

GENERAL NOTES

PL

U

M

BI

N G

W

AT

ER

N

EW

W

O R

K

PL

AN

P-3

PLUMBING WATER NEW WORK PLAN1

M-1

A

PP

R O

VE

D

A R

C H

IT

EC

TU

R

A L

M

EC

H A

N

IC

A L

EL

EC

TR

IC

A L

PL

U

M B

IN

G

R

EV

D A

TE

B

Y D

ES

C

R

IP

TI

O

N

DWN BY

SHEET OF

PROJECT NUMBER

I N D

AI

N

HEALTH

SERVI C

E

P H S -

D

EP

A R

TM

EN

T O

F H

EA

LT

H

ED

U

C A

TI

O

N , A

N D

W

EL

FA

R

E O

FF

IC

E O

F

FA

C

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

A N

D

PR

O

PE

R

TY

M A

N A

G

EM

EN

T

R

EG

IO

N

A L

O

FF

IC

E

O F

FA

C

IL

IT

IE

S

EN

G

IN

EE

R

IN

G A

N D

C O

N

ST

R U

C

TI

O N

STAMP

DATE

SCALE

CKD BY

GENERAL

DUCTWORK SYMBOLS

ABBREVIATIONS

M3

GENERAL NOTESMECHANICAL SYMBOL LEGEND

DEMOLITION GENERAL NOTES

M

EC

H

AN

IC

AL

S

YM

BO

L

LE

G

EN

D

G

EN

ER

AL

P

R O

JE

C

T N

O

TE

S

3 2

A

PP

R O

VE

D

A R

C H

IT

EC

TU

R

A L

M

EC

H A

N

IC

A L

EL

EC

TR

IC

A L

PL

U

M B

IN

G

R

EV

D A

TE

B

Y D

ES

C

R

IP

TI

O

N

DWN BY

SHEET OF

PROJECT NUMBER

I N D

AI

N

HEALTH

SERVI C

E

P H S -

KEY PLAN

N.T.S.

D

EP

A R

TM

EN

T O

F H

EA

LT

H

ED

U

C A

TI

O

N , A

N D

W

EL

FA

R

E O

FF

IC

E O

F

FA

C

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

A N

D

PR

O

PE

R

TY

M A

N A

G

EM

EN

T

R

EG

IO

N

A L

O

FF

IC

E

O F

FA

C

IL

IT

IE

S

EN

G

IN

EE

R

IN

G A

N D

C O

N

ST

R U

C

TI

O N

STAMP

DATE

SCALE

CKD BY

KEYED NOTES

GENERAL NOTES

M

EC

H

AN

IC

AL

N

EW

W O

R K

P

LA

N

M-2

MECHANICAL NEW WORK PLAN - PHARMACY]

MECHANICAL NEW WORK PLAN - SECURITY OFFICE2

K

S

T

U

10 8 5 4 3 21114161820212224

J

H

G

F

E

M-3

M

EC

H

AN

IC

AL

N

EW

W O

R K

R O

O F

PL

AN

A

PP

R O

VE

D

A R

C H

IT

EC

TU

R

A L

M

EC

H A

N

IC

A L

EL

EC

TR

IC

A L

PL

U

M B

IN

G

R

EV

D A

TE

B

Y D

ES

C

R

IP

TI

O

N

DWN BY

SHEET OF

PROJECT NUMBER

I N D

AI

N

HEALTH

SERVI C

E

P H S -

D

EP

A R

TM

EN

T O

F H

EA

LT

H

ED

U

C A

TI

O

N , A

N D

W

EL

FA

R

E O

FF

IC

E O

F

FA

C

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

A N

D

PR

O

PE

R

TY

M A

N A

G

EM

EN

T

R

EG

IO

N

A L

O

FF

IC

E

O F

FA

C

IL

IT

IE

S

EN

G

IN

EE

R

IN

G A

N D

C O

N

ST

R U

C

TI

O N

STAMP

DATE

SCALE

CKD BY

KEYED NOTES

GENERAL NOTES

MECHANICAL NEW WORK ROOF PLAN1

M-5

M

EC

H

AN

IC

AL

E Q

U

IP

M

EN

T

SC

H

ED

U

LE

S A

PP

R

O

VE

D A

R C

H

IT

EC

TU

R A

L M

EC

H

A N

IC

A

L

EL

EC

TR

IC

A

L

PL

U M

B

IN

G

R

EV

D A

TE

B

Y D

ES

C

R

IP

TI

O

N

DWN BY

SHEET OF

PROJECT NUMBER

I N D

AI

N

HEALTH

SERVI C

E

P H S -

D

EP

A R

TM

EN

T O

F H

EA

LT

H

ED

U

C A

TI

O

N , A

N D

W

EL

FA

R

E O

FF

IC

E O

F

FA

C

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

A N

D

PR

O

PE

R

TY

M A

N A

G

EM

EN

T

R

EG

IO

N

A L

O

FF

IC

E

O F

FA

C

IL

IT

IE

S

EN

G

IN

EE

R

IN

G A

N D

C O

N

ST

R U

C

TI

O N

STAMP

DATE

SCALE

CKD BY

AIR DISTRIBUTION DEVICE SCHEDULE

MARK DESCRIPTION MANUFACTURER AND

MODEL TYPE MATERIAL FINISH REMARKS

S1 SUPPLY DIFFUSER PRICE

ASCDA SQUARE CONE DIFFUSER ALUMINUM BAKED ENAMEL, WHITE 24 X 24 RECTANGULAR SUPPLY DIFFUSER, LAY-IN CEILING FRAME

S2 SUPPLY DIFFUSER PRICE

ASCDA SQUARE CONE DIFFUSER ALUMINUM BAKED ENAMEL, WHITE 12 X 12 RECTANGULAR SUPPLY DIFFUSER, LAY-IN CEILING FRAME

S3 SUPPLY DIFFUSER PRICE

ASCDA SQUARE CONE DIFFUSER ALUMINUM BAKED ENAMEL, WHITE 24 X 24 RECTANGULAR SUPPLY DIFFUSER WITH OPPOSED BLADE DAMPER, HARD CEILING FRAME

R1 RETURN GRILLE PRICE

EGG CRATE

RETURN ALUMINUM BAKED ENAMEL, WHITE 24 X 24 RECTANGULAR RETURN GRILL, 1/2" X 1/2" EGG CRATE GRILL, LAY-IN FRAME, DUCTED RETURN

R2 RETURN GRILLE PRICE

EGG CRATE

RETURN ALUMINUM BAKED ENAMEL, WHITE 12 X 12 RECTANGULAR RETURN GRILL, 1/2" X 1/2" EGG CRATE GRILL, LAY-IN FRAME, DUCTED RETURN

R3 RETURN GRILLE PRICE

80DAL

EGG CRATE

RETURN ALUMINUM BAKED ENAMEL, WHITE 24 X 24 RECTANGULAR RETURN GRILL, 1/2" X 1/2" EGG CRATE GRILL, 1-1/4" HARD CEILING FRAME , ALUMINUM OPPOSED BLADE DAMPER, DUCTED RETURN

EQUIVALENT MANUFACTURES:

1. TITUS, KRUEGER, NAILOR

NOTES:

1. SIZE AND INSTALL REFRIGERANT PIPING BETWEEN OUTDOOR UNIT AND ASSOCIATED FAN COIL ACCORDING TO MANUFACTURER'S RECOMMENDATIONS. PIPING SHALL NOT EXCEED LENGTH RECOMMENDED BY MANUFACTURER.

2. ACCESSORIES: LOW AMBIENT HEATING TO -4°F, AND ALL CONTROLS AND ACCESSORIES FOR A COMPLETE AND OPERATIONAL SYSTEM. (OPERATING RANGE IN HEATING: -4°F TO +60°F.)

3. UNIT SELECTED AT AN ELEVATION OF 7,200 FT ABOVE SEA LEVEL.

4. PROVIDE ALL SERVICE AND OPERATIONAL CLEARANCES AS REQUIRED.

5. MOUNT UNIT LEVEL ON EQUIPMENT SUPPORTS. CONTRACTOR SHALL PROVIDE SHORTEST ROUTING OF 4-410A REFRIGERANT LINES TO ASSOCIATED INDOOR UNITS.

6. ELECTRICAL CONTRACTOR SHALL PROVIDE DISCONNECT SWITCH. REFER TO ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION.

7. POWER TO INDOOR UNITS FED FROM OUTDOOR UNIT. COORDINATE WITH ELECTRICAL CONTRACTOR TO ROUTE POWER TO INDOOR FAN COIL UNITS.

8. PROVIDE LOW AMBIENT COOLING ACCESSORIES AND CONTROLS.

9. HEAT PUMP UNIT. PROVIDE WIND BAFFLE AND COLD WEATHER KIT.

HEAT PUMP OUTDOOR CONDENSING UNIT SCHEDULE

MARK INDOOR UNIT

CONNECTION

O/A SUMMER

TEMP °F O/A WINTER TEMP °F

TOTAL COOLING

CAPACITY (MBH) SEER

TOTAL HEATING

CAPACITY (MBH) COP

ELECTRICAL

WEIGHT

(LBS.) MANUFACTURER AND MODEL NOTES

VOLT/PH MCA MFA

HP-1 EV-1 94 BD / 64 WB 12 DB 32.2 15.9 33.5 2.78 230/1ɸ 19.8 20 150 DAIKIN

RX36NMVJUA SEE NOTE 1-8

HP-2 EV-2 94 BD / 64 WB 12 DB 22.2 19 25.7 3.45 230/1ɸ 16.4 20 125 DAIKIN

RX24AXVJU SEE NOTE 1-8

ACCESSORIES:

FURNISH UNIT WITH HARD-WIRED MANUFACTURER'S 7-DAY PROGRAMMABLE CONTROLLER, LOW AMBIENT COOLING KIT, CONDENSATE PUMP.

NOTES:

1. UNIT SELECTED AT ELEVATION OF 7,200 FT ABOVE SEA LEVEL.

2. POWER CONDENSATE PUMP THROUGH UNIT. SHUTDOWN UNIT ON PUMP OVERFLOW.

3. PROVIDE ALL VALVES, FITTINGS AND ACCESSORIES FOR A COMPLETE AND OPERATIONAL SYSTEM.

4. PROVIDE ALL SERVICE AND OPERATIONAL CLEARANCES AS REQUIRED. INSTALL PER MANUFACTURER'S INSTRUCTIONS.

5. ELECTRICITY TO POWER INDOOR UNITS FED FROM EXTERIOR UNIT. REFER TO EXTERIOR CONDENSING UNIT SCHEDULE FOR VOLTAGE AND DISCONNECT INFORMATION.

HEAT PUMP INDOOR EVAPORATOR SCHEDULE

MARK LOCATION MAX CFM

COOLING CAPACITY HEATING

CAPACITY ELECTRICAL

FILTER WEIGHT (LBS.) MANUFACTURER AND MODEL NOTES

ENT. AIR

DB/WB

TOTAL

MBH

SENSIBLE

MBH TOTAL MBH VOLT /

PH MCA MOCP

EV-1 DISPENSING WORKROOM 960 78/63 34.4 22.2 36 SEE NOTE 5 WASHABLE 50 DAIKIN

FTX36 SEE NOTES 1-5

EV-2 OFFICE / TRAINING ROOM 716 78/63 24.0 15.7 27.6 SEE NOTE 5 WASHABLE 40 DAIKIN

FTX24 SEE NOTES 1-5

VENTILATION CALCULATION

SEQUENCE OF OPERATIONS (SOO):

T

System name

Condition analyzed (impacts Ez, Vdz, Vpz and Vps)

All zones are included in the VRP calculation

AHU-3 & AHU-4

Heating

Yes

Zone Zone Floor Area

Zone Name and Number

Occupancy Category

Az (sq ft)

Supervisor Office PD-01 Consulting PD-03 Consulting PD-04 Vestibule PD-02 Intake PD-05 Consulting PD-07 Consuting PD-08 Pharmacy Storage PD-09 Training Room PD-11 Dispensing Workroom PD-10

Office space Office space Office space Corridors Office space Office space Office space Occupiable storage rooms for dry materials Conference / meeting Pharmacy (prep, area)

Population

Pz (people)

2.00 2.00 2.00 0.00 1.00 2.00 2.00 1.00 6.00 5.00

0.80 0.80 0.80 0.80 0.80 0.80 0.80 0.80 0.80 0.80

Zone Air Distribution

Effectiveness

Ez

Zone Outdoor Airflow

Voz (cfm)

21.20 17.30 17.38

7.43 10.30 17.38 17.38 17.05 60.75

217.10 0.00

Zone Discharge Airflow

Vdz (cfm)

1,275

Zone Primary Airflow

Vpz (cfm)

1,275

1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00

1.00 1.11 1.11 1.00 1.00 1.11 1.11 1.11 1.00 1.00 0.00

Zone Secondary Recirculation

Fraction

Er

Zone Primary Air Fraction

Ep

System area

System population

Sum of zone population

Occupant diversity

Uncorrected outdoor air intake

System primary airflow (at condition analyzed)

Average outdoor air fraction

As

Ps sum of Pz

D

Vou

Vps

Xs

(sq ft)

(people)

(people)

(cfm)

(cfm)

1,808 Net occupiable floor area served by the ventilation system

22.00

23.00 ∑Pz

0.95 Ps / ∑Pz

316.85 D ∑ (Rp Pz) + ∑(Ra Az)

3,260

0.09 Vou / Vps

Outdoor air intake flow provided (measured or design) (cfm) 350

SMOKE DAMPER SCHEDULE

MARK DESCRIPTION MANUFACTURER AND

MODEL SIZE QUANTITY ACTUATOR MAKE AND MODEL ELECTRICAL (VOLTS / PHASE / HERTZ)

SD-1, -2, -3, -4, -5, -7, -8, -11, -12 ROUND SMOKE DAMPER GREENHECK

SMDR-501 10"Ø 9 HONEYWELL MS4104F1010 120 / 1 / 60

SD-6 ROUND SMOKE DAMPER GREENHECK

SMDR-501 14"Ø 1 HONEYWELL MS4104F1010 120 / 1 / 60

SD-9 RECTANGULAR SMOKE

DAMPER

GREENHECK

SMD-201 24" X 12" 1 HONEYWELL MS4104F1010 120 / 1 / 60

SD-10 RECTANGULAR SMOKE

DAMPER

GREENHECK

SMD-201 14" X 10" 1 HONEYWELL MS4104F1010 120 / 1 / 60

SD-13, -14 RECTANGULAR SMOKE

DAMPER

GREENHECK

SMD-201 10" X 12" 2 HONEYWELL MS4104F1010 120 / 1 / 60

DDC POINTS LIST:

HEAT PUMP (HP-1 AND HP-2) CONTROL DIAGRAM:

EQUIVALENT MANUFACTURES:

1. RUSKIN, POTTORFF, NAILOR

A

PP

R O

VE

D

A R

C H

IT

EC

TU

R

A L

M

EC

H A

N

IC

A L

EL

EC

TR

IC

A L

PL

U

M B

IN

G

R

EV

D A

TE

B

Y D

ES

C

R

IP

TI

O

N

DWN BY

SHEET OF

PROJECT NUMBER

I N D

AI

N

HEALTH

SERVI C

E

P H S -

KEY PLAN

N.T.S.

D

EP

A R

TM

EN

T O

F H

EA

LT

H

ED

U

C A

TI

O

N , A

N D

W

EL

FA

R

E O

FF

IC

E O

F

FA

C

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

A N

D

PR

O

PE

R

TY

M A

N A

G

EM

EN

T

R

EG

IO

N

A L

O

FF

IC

E

O F

FA

C

IL

IT

IE

S

EN

G

IN

EE

R

IN

G A

N D

C O

N

ST

R U

C

TI

O N

STAMP

DATE

SCALE

CKD BY

KEYED NOTES

GENERAL NOTES

EL

EC

TR

IC

AL

L

IG

H

TI

N

G P

LA

N

E-3

ELECTRICAL LIGHTING PLAN1

ELECTRICAL LIGHTING PLAN2

File details come from the government source that posted it. Updated .