Attachment J02 Drawings.pdf
PDF 34 MB Posted
- Attached to
- Santa Fe Indian Hospital Pharmacy Renovation
- Solicitation number
- 75H70123R00015
About this file
This document provides details for a federal construction solicitation notice seeking offers for the Santa Fe Indian Hospital Pharmacy Renovation project. The project scope involves a two-phased renovation of the existing pharmacy department and relocation of the security office at the Santa Fe Indian Hospital located in Santa Fe, New Mexico. Phase 1 includes removal of existing office furnishings and demolition of the pharmacy department. Phase 2 includes construction and renovation of the pharmacy department. The period of performance is 240 calendar days from notice to proceed. The construction magnitude is estimated between $1,000,000 to $5,000,000. A site visit is scheduled for May 31, 2023 at 10:00 AM MDT. The agency intends to award a single firm fixed price contract evaluated with lowest price technically acceptable criteria. The solicitation will be posted on the website for interested offerors to download.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Attachment J02. Drawings Solicitation Number: 75H70123R00015
10 8 5 4 3 2
P
A
PP
R O
VE
D
A R
C H
IT
EC
TU
R
A L
M
EC
H A
N
IC
A L
EL
EC
TR
IC
A L
PL
U
M B
IN
G
R
EV
D A
TE
B
Y D
ES
C
R
IP
TI
O
N
DWN BY
SHEET OF
PROJECT NUMBER
I N D
AI
N
HEALTH
SERVI C
E
P H S -
NOT FOR C
ONSTRUCTIO
N
KEY PLAN
N.T.S.
D
EP
A R
TM
EN
T O
F H
EA
LT
H
ED
U
C A
TI
O
N , A
N D
W
EL
FA
R
E O
FF
IC
E O
F
FA
C
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
A N
D
PR
O
PE
R
TY
M A
N A
G
EM
EN
T
R
EG
IO
N
A L
O
FF
IC
E
O F
FA
C
IL
IT
IE
S
EN
G
IN
EE
R
IN
G A
N D
C O
N
ST
R U
C
TI
O N
STAMP
DATE
SCALE
CKD BY
D
EM
O
LI
TI
O
N F
LO
O
R P
LA
N
AD-1
KEYED NOTES
GENERAL NOTES LEGEND:
DEMOLITION FLOOR PLAN
A
PP
R O
VE
D
A R
C H
IT
EC
TU
R
A L
M
EC
H A
N
IC
A L
EL
EC
TR
IC
A L
PL
U
M B
IN
G
R
EV
D A
TE
B
Y D
ES
C
R
IP
TI
O
N
DWN BY
SHEET OF
PROJECT NUMBER
I N D
AI
N
HEALTH
SERVI C
E
P H S -
NOT FOR C
ONSTRUCTIO
N
KEY PLAN
N.T.S.
D
EP
A R
TM
EN
T O
F H
EA
LT
H
ED
U
C A
TI
O
N , A
N D
W
EL
FA
R
E O
FF
IC
E O
F
FA
C
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
A N
D
PR
O
PE
R
TY
M A
N A
G
EM
EN
T
R
EG
IO
N
A L
O
FF
IC
E
O F
FA
C
IL
IT
IE
S
EN
G
IN
EE
R
IN
G A
N D
C O
N
ST
R U
C
TI
O N
STAMP
DATE
SCALE
CKD BY
R
EN
O
VA
TI
O
N F
LO
O
R P
LA
N
A-1
KEYED NOTES
GENERAL NOTES LEGEND
FLOOR PLAN1
CONCRETE SLAB INFILL2
A
PP
R O
VE
D
A R
C H
IT
EC
TU
R
A L
M
EC
H A
N
IC
A L
EL
EC
TR
IC
A L
PL
U
M B
IN
G
R
EV
D A
TE
B
Y D
ES
C
R
IP
TI
O
N
DWN BY
SHEET OF
PROJECT NUMBER
I N D
AI
N
HEALTH
SERVI C
E
P H S -
NOT FOR C
ONSTRUCTIO
N
KEY PLAN
N.T.S.
D
EP
A R
TM
EN
T O
F H
EA
LT
H
ED
U
C A
TI
O
N , A
N D
W
EL
FA
R
E O
FF
IC
E O
F
FA
C
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
A N
D
PR
O
PE
R
TY
M A
N A
G
EM
EN
T
R
EG
IO
N
A L
O
FF
IC
E
O F
FA
C
IL
IT
IE
S
EN
G
IN
EE
R
IN
G A
N D
C O
N
ST
R U
C
TI
O N
STAMP
DATE
SCALE
CKD BY
R
EN
O
VA
TI
O
N D
IM
EN
SI
O
N F
LO
O
R P
LA
N
A-1.1
KEYED NOTES
GENERAL NOTES
LEGEND
DIMENSION FLOOR PLAN1
10 8 5 410 8 5 410 8 5 4
PPP
3 23 23 2
A
PP
R O
VE
D
A R
C H
IT
EC
TU
R
A L
M
EC
H A
N
IC
A L
EL
EC
TR
IC
A L
PL
U
M B
IN
G
R
EV
D A
TE
B
Y D
ES
C
R
IP
TI
O
N
DWN BY
SHEET OF
PROJECT NUMBER
I N D
AI
N
HEALTH
SERVI C
E
P H S -
KEY PLAN
N.T.S.
D
EP
A R
TM
EN
T O
F H
EA
LT
H
ED
U
C A
TI
O
N , A
N D
W
EL
FA
R
E O
FF
IC
E O
F
FA
C
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
A N
D
PR
O
PE
R
TY
M A
N A
G
EM
EN
T
R
EG
IO
N
A L
O
FF
IC
E
O F
FA
C
IL
IT
IE
S
EN
G
IN
EE
R
IN
G A
N D
C O
N
ST
R U
C
TI
O N
STAMP
DATE
SCALE
CKD BY
KEYED NOTES
GENERAL NOTES
FI
R
E
PR
O
TE
C
TI
O N
N
EW
W O
R K
PL
AN
FP-1
FIRE PROTECTION NEW WORK PLAN1
FIRE PROTECTION NEW WORK PLAN - SECURITY OFFICE2
10 8 5 4
3 2
P
A
PP
R O
VE
D
A R
C H
IT
EC
TU
R
A L
M
EC
H A
N
IC
A L
EL
EC
TR
IC
A L
PL
U
M B
IN
G
R
EV
D A
TE
B
Y D
ES
C
R
IP
TI
O
N
DWN BY
SHEET OF
PROJECT NUMBER
I N D
AI
N
HEALTH
SERVI C
E
P H S -
KEY PLAN
N.T.S.
D
EP
A R
TM
EN
T O
F H
EA
LT
H
ED
U
C A
TI
O
N , A
N D
W
EL
FA
R
E O
FF
IC
E O
F
FA
C
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
A N
D
PR
O
PE
R
TY
M A
N A
G
EM
EN
T
R
EG
IO
N
A L
O
FF
IC
E
O F
FA
C
IL
IT
IE
S
EN
G
IN
EE
R
IN
G A
N D
C O
N
ST
R U
C
TI
O N
STAMP
DATE
SCALE
CKD BY
KEYED NOTES
GENERAL NOTES
PL
U
M
BI
N G
D
EM
O P
LA
N
DP-1
PLUMBING DEMO PLAN - PHARMACY1
PLUMBING DEMO PLAN - SECURITY OFFICE1
10 8 5 410 8 5 4
PP
A
PP
R O
VE
D
A R
C H
IT
EC
TU
R
A L
M
EC
H A
N
IC
A L
EL
EC
TR
IC
A L
PL
U
M B
IN
G
R
EV
D A
TE
B
Y D
ES
C
R
IP
TI
O
N
DWN BY
SHEET OF
PROJECT NUMBER
I N D
AI
N
HEALTH
SERVI C
E
P H S -
KEY PLAN
N.T.S.
D
EP
A R
TM
EN
T O
F H
EA
LT
H
ED
U
C A
TI
O
N , A
N D
W
EL
FA
R
E O
FF
IC
E O
F
FA
C
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
A N
D
PR
O
PE
R
TY
M A
N A
G
EM
EN
T
R
EG
IO
N
A L
O
FF
IC
E
O F
FA
C
IL
IT
IE
S
EN
G
IN
EE
R
IN
G A
N D
C O
N
ST
R U
C
TI
O N
STAMP
DATE
SCALE
CKD BY
KEYED NOTES
GENERAL NOTES
PL
U
M
BI
N G
W
AS
TE
A
N D
V
EN
T N
EW
W
O R
K
PL
AN
P-2
PLUMBING WASTE AND VENT NEW WORK PLAN1
10 8 5 410 8 5 4
PP
A
PP
R O
VE
D
A R
C H
IT
EC
TU
R
A L
M
EC
H A
N
IC
A L
EL
EC
TR
IC
A L
PL
U
M B
IN
G
R
EV
D A
TE
B
Y D
ES
C
R
IP
TI
O
N
DWN BY
SHEET OF
PROJECT NUMBER
I N D
AI
N
HEALTH
SERVI C
E
P H S -
KEY PLAN
N.T.S.
D
EP
A R
TM
EN
T O
F H
EA
LT
H
ED
U
C A
TI
O
N , A
N D
W
EL
FA
R
E O
FF
IC
E O
F
FA
C
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
A N
D
PR
O
PE
R
TY
M A
N A
G
EM
EN
T
R
EG
IO
N
A L
O
FF
IC
E
O F
FA
C
IL
IT
IE
S
EN
G
IN
EE
R
IN
G A
N D
C O
N
ST
R U
C
TI
O N
STAMP
DATE
SCALE
CKD BY
KEYED NOTES
GENERAL NOTES
PL
U
M
BI
N G
W
AT
ER
N
EW
W
O R
K
PL
AN
P-3
PLUMBING WATER NEW WORK PLAN1
M-1
A
PP
R O
VE
D
A R
C H
IT
EC
TU
R
A L
M
EC
H A
N
IC
A L
EL
EC
TR
IC
A L
PL
U
M B
IN
G
R
EV
D A
TE
B
Y D
ES
C
R
IP
TI
O
N
DWN BY
SHEET OF
PROJECT NUMBER
I N D
AI
N
HEALTH
SERVI C
E
P H S -
D
EP
A R
TM
EN
T O
F H
EA
LT
H
ED
U
C A
TI
O
N , A
N D
W
EL
FA
R
E O
FF
IC
E O
F
FA
C
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
A N
D
PR
O
PE
R
TY
M A
N A
G
EM
EN
T
R
EG
IO
N
A L
O
FF
IC
E
O F
FA
C
IL
IT
IE
S
EN
G
IN
EE
R
IN
G A
N D
C O
N
ST
R U
C
TI
O N
STAMP
DATE
SCALE
CKD BY
GENERAL
DUCTWORK SYMBOLS
ABBREVIATIONS
M3
GENERAL NOTESMECHANICAL SYMBOL LEGEND
DEMOLITION GENERAL NOTES
M
EC
H
AN
IC
AL
S
YM
BO
L
LE
G
EN
D
G
EN
ER
AL
P
R O
JE
C
T N
O
TE
S
3 2
A
PP
R O
VE
D
A R
C H
IT
EC
TU
R
A L
M
EC
H A
N
IC
A L
EL
EC
TR
IC
A L
PL
U
M B
IN
G
R
EV
D A
TE
B
Y D
ES
C
R
IP
TI
O
N
DWN BY
SHEET OF
PROJECT NUMBER
I N D
AI
N
HEALTH
SERVI C
E
P H S -
KEY PLAN
N.T.S.
D
EP
A R
TM
EN
T O
F H
EA
LT
H
ED
U
C A
TI
O
N , A
N D
W
EL
FA
R
E O
FF
IC
E O
F
FA
C
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
A N
D
PR
O
PE
R
TY
M A
N A
G
EM
EN
T
R
EG
IO
N
A L
O
FF
IC
E
O F
FA
C
IL
IT
IE
S
EN
G
IN
EE
R
IN
G A
N D
C O
N
ST
R U
C
TI
O N
STAMP
DATE
SCALE
CKD BY
KEYED NOTES
GENERAL NOTES
M
EC
H
AN
IC
AL
N
EW
W O
R K
P
LA
N
M-2
MECHANICAL NEW WORK PLAN - PHARMACY]
MECHANICAL NEW WORK PLAN - SECURITY OFFICE2
K
S
T
U
10 8 5 4 3 21114161820212224
J
H
G
F
E
M-3
M
EC
H
AN
IC
AL
N
EW
W O
R K
R O
O F
PL
AN
A
PP
R O
VE
D
A R
C H
IT
EC
TU
R
A L
M
EC
H A
N
IC
A L
EL
EC
TR
IC
A L
PL
U
M B
IN
G
R
EV
D A
TE
B
Y D
ES
C
R
IP
TI
O
N
DWN BY
SHEET OF
PROJECT NUMBER
I N D
AI
N
HEALTH
SERVI C
E
P H S -
D
EP
A R
TM
EN
T O
F H
EA
LT
H
ED
U
C A
TI
O
N , A
N D
W
EL
FA
R
E O
FF
IC
E O
F
FA
C
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
A N
D
PR
O
PE
R
TY
M A
N A
G
EM
EN
T
R
EG
IO
N
A L
O
FF
IC
E
O F
FA
C
IL
IT
IE
S
EN
G
IN
EE
R
IN
G A
N D
C O
N
ST
R U
C
TI
O N
STAMP
DATE
SCALE
CKD BY
KEYED NOTES
GENERAL NOTES
MECHANICAL NEW WORK ROOF PLAN1
M-5
M
EC
H
AN
IC
AL
E Q
U
IP
M
EN
T
SC
H
ED
U
LE
S A
PP
R
O
VE
D A
R C
H
IT
EC
TU
R A
L M
EC
H
A N
IC
A
L
EL
EC
TR
IC
A
L
PL
U M
B
IN
G
R
EV
D A
TE
B
Y D
ES
C
R
IP
TI
O
N
DWN BY
SHEET OF
PROJECT NUMBER
I N D
AI
N
HEALTH
SERVI C
E
P H S -
D
EP
A R
TM
EN
T O
F H
EA
LT
H
ED
U
C A
TI
O
N , A
N D
W
EL
FA
R
E O
FF
IC
E O
F
FA
C
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
A N
D
PR
O
PE
R
TY
M A
N A
G
EM
EN
T
R
EG
IO
N
A L
O
FF
IC
E
O F
FA
C
IL
IT
IE
S
EN
G
IN
EE
R
IN
G A
N D
C O
N
ST
R U
C
TI
O N
STAMP
DATE
SCALE
CKD BY
AIR DISTRIBUTION DEVICE SCHEDULE
MARK DESCRIPTION MANUFACTURER AND
MODEL TYPE MATERIAL FINISH REMARKS
S1 SUPPLY DIFFUSER PRICE
ASCDA SQUARE CONE DIFFUSER ALUMINUM BAKED ENAMEL, WHITE 24 X 24 RECTANGULAR SUPPLY DIFFUSER, LAY-IN CEILING FRAME
S2 SUPPLY DIFFUSER PRICE
ASCDA SQUARE CONE DIFFUSER ALUMINUM BAKED ENAMEL, WHITE 12 X 12 RECTANGULAR SUPPLY DIFFUSER, LAY-IN CEILING FRAME
S3 SUPPLY DIFFUSER PRICE
ASCDA SQUARE CONE DIFFUSER ALUMINUM BAKED ENAMEL, WHITE 24 X 24 RECTANGULAR SUPPLY DIFFUSER WITH OPPOSED BLADE DAMPER, HARD CEILING FRAME
R1 RETURN GRILLE PRICE
EGG CRATE
RETURN ALUMINUM BAKED ENAMEL, WHITE 24 X 24 RECTANGULAR RETURN GRILL, 1/2" X 1/2" EGG CRATE GRILL, LAY-IN FRAME, DUCTED RETURN
R2 RETURN GRILLE PRICE
EGG CRATE
RETURN ALUMINUM BAKED ENAMEL, WHITE 12 X 12 RECTANGULAR RETURN GRILL, 1/2" X 1/2" EGG CRATE GRILL, LAY-IN FRAME, DUCTED RETURN
R3 RETURN GRILLE PRICE
80DAL
EGG CRATE
RETURN ALUMINUM BAKED ENAMEL, WHITE 24 X 24 RECTANGULAR RETURN GRILL, 1/2" X 1/2" EGG CRATE GRILL, 1-1/4" HARD CEILING FRAME , ALUMINUM OPPOSED BLADE DAMPER, DUCTED RETURN
EQUIVALENT MANUFACTURES:
1. TITUS, KRUEGER, NAILOR
NOTES:
1. SIZE AND INSTALL REFRIGERANT PIPING BETWEEN OUTDOOR UNIT AND ASSOCIATED FAN COIL ACCORDING TO MANUFACTURER'S RECOMMENDATIONS. PIPING SHALL NOT EXCEED LENGTH RECOMMENDED BY MANUFACTURER.
2. ACCESSORIES: LOW AMBIENT HEATING TO -4°F, AND ALL CONTROLS AND ACCESSORIES FOR A COMPLETE AND OPERATIONAL SYSTEM. (OPERATING RANGE IN HEATING: -4°F TO +60°F.)
3. UNIT SELECTED AT AN ELEVATION OF 7,200 FT ABOVE SEA LEVEL.
4. PROVIDE ALL SERVICE AND OPERATIONAL CLEARANCES AS REQUIRED.
5. MOUNT UNIT LEVEL ON EQUIPMENT SUPPORTS. CONTRACTOR SHALL PROVIDE SHORTEST ROUTING OF 4-410A REFRIGERANT LINES TO ASSOCIATED INDOOR UNITS.
6. ELECTRICAL CONTRACTOR SHALL PROVIDE DISCONNECT SWITCH. REFER TO ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION.
7. POWER TO INDOOR UNITS FED FROM OUTDOOR UNIT. COORDINATE WITH ELECTRICAL CONTRACTOR TO ROUTE POWER TO INDOOR FAN COIL UNITS.
8. PROVIDE LOW AMBIENT COOLING ACCESSORIES AND CONTROLS.
9. HEAT PUMP UNIT. PROVIDE WIND BAFFLE AND COLD WEATHER KIT.
HEAT PUMP OUTDOOR CONDENSING UNIT SCHEDULE
MARK INDOOR UNIT
CONNECTION
O/A SUMMER
TEMP °F O/A WINTER TEMP °F
TOTAL COOLING
CAPACITY (MBH) SEER
TOTAL HEATING
CAPACITY (MBH) COP
ELECTRICAL
WEIGHT
(LBS.) MANUFACTURER AND MODEL NOTES
VOLT/PH MCA MFA
HP-1 EV-1 94 BD / 64 WB 12 DB 32.2 15.9 33.5 2.78 230/1ɸ 19.8 20 150 DAIKIN
RX36NMVJUA SEE NOTE 1-8
HP-2 EV-2 94 BD / 64 WB 12 DB 22.2 19 25.7 3.45 230/1ɸ 16.4 20 125 DAIKIN
RX24AXVJU SEE NOTE 1-8
ACCESSORIES:
FURNISH UNIT WITH HARD-WIRED MANUFACTURER'S 7-DAY PROGRAMMABLE CONTROLLER, LOW AMBIENT COOLING KIT, CONDENSATE PUMP.
NOTES:
1. UNIT SELECTED AT ELEVATION OF 7,200 FT ABOVE SEA LEVEL.
2. POWER CONDENSATE PUMP THROUGH UNIT. SHUTDOWN UNIT ON PUMP OVERFLOW.
3. PROVIDE ALL VALVES, FITTINGS AND ACCESSORIES FOR A COMPLETE AND OPERATIONAL SYSTEM.
4. PROVIDE ALL SERVICE AND OPERATIONAL CLEARANCES AS REQUIRED. INSTALL PER MANUFACTURER'S INSTRUCTIONS.
5. ELECTRICITY TO POWER INDOOR UNITS FED FROM EXTERIOR UNIT. REFER TO EXTERIOR CONDENSING UNIT SCHEDULE FOR VOLTAGE AND DISCONNECT INFORMATION.
HEAT PUMP INDOOR EVAPORATOR SCHEDULE
MARK LOCATION MAX CFM
COOLING CAPACITY HEATING
CAPACITY ELECTRICAL
FILTER WEIGHT (LBS.) MANUFACTURER AND MODEL NOTES
ENT. AIR
DB/WB
TOTAL
MBH
SENSIBLE
MBH TOTAL MBH VOLT /
PH MCA MOCP
EV-1 DISPENSING WORKROOM 960 78/63 34.4 22.2 36 SEE NOTE 5 WASHABLE 50 DAIKIN
FTX36 SEE NOTES 1-5
EV-2 OFFICE / TRAINING ROOM 716 78/63 24.0 15.7 27.6 SEE NOTE 5 WASHABLE 40 DAIKIN
FTX24 SEE NOTES 1-5
VENTILATION CALCULATION
SEQUENCE OF OPERATIONS (SOO):
T
System name
Condition analyzed (impacts Ez, Vdz, Vpz and Vps)
All zones are included in the VRP calculation
AHU-3 & AHU-4
Heating
Yes
Zone Zone Floor Area
Zone Name and Number
Occupancy Category
Az (sq ft)
Supervisor Office PD-01 Consulting PD-03 Consulting PD-04 Vestibule PD-02 Intake PD-05 Consulting PD-07 Consuting PD-08 Pharmacy Storage PD-09 Training Room PD-11 Dispensing Workroom PD-10
Office space Office space Office space Corridors Office space Office space Office space Occupiable storage rooms for dry materials Conference / meeting Pharmacy (prep, area)
Population
Pz (people)
2.00 2.00 2.00 0.00 1.00 2.00 2.00 1.00 6.00 5.00
0.80 0.80 0.80 0.80 0.80 0.80 0.80 0.80 0.80 0.80
Zone Air Distribution
Effectiveness
Ez
Zone Outdoor Airflow
Voz (cfm)
21.20 17.30 17.38
7.43 10.30 17.38 17.38 17.05 60.75
217.10 0.00
Zone Discharge Airflow
Vdz (cfm)
1,275
Zone Primary Airflow
Vpz (cfm)
1,275
1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
1.00 1.11 1.11 1.00 1.00 1.11 1.11 1.11 1.00 1.00 0.00
Zone Secondary Recirculation
Fraction
Er
Zone Primary Air Fraction
Ep
System area
System population
Sum of zone population
Occupant diversity
Uncorrected outdoor air intake
System primary airflow (at condition analyzed)
Average outdoor air fraction
As
Ps sum of Pz
D
Vou
Vps
Xs
(sq ft)
(people)
(people)
(cfm)
(cfm)
1,808 Net occupiable floor area served by the ventilation system
22.00
23.00 ∑Pz
0.95 Ps / ∑Pz
316.85 D ∑ (Rp Pz) + ∑(Ra Az)
3,260
0.09 Vou / Vps
Outdoor air intake flow provided (measured or design) (cfm) 350
SMOKE DAMPER SCHEDULE
MARK DESCRIPTION MANUFACTURER AND
MODEL SIZE QUANTITY ACTUATOR MAKE AND MODEL ELECTRICAL (VOLTS / PHASE / HERTZ)
SD-1, -2, -3, -4, -5, -7, -8, -11, -12 ROUND SMOKE DAMPER GREENHECK
SMDR-501 10"Ø 9 HONEYWELL MS4104F1010 120 / 1 / 60
SD-6 ROUND SMOKE DAMPER GREENHECK
SMDR-501 14"Ø 1 HONEYWELL MS4104F1010 120 / 1 / 60
SD-9 RECTANGULAR SMOKE
DAMPER
GREENHECK
SMD-201 24" X 12" 1 HONEYWELL MS4104F1010 120 / 1 / 60
SD-10 RECTANGULAR SMOKE
DAMPER
GREENHECK
SMD-201 14" X 10" 1 HONEYWELL MS4104F1010 120 / 1 / 60
SD-13, -14 RECTANGULAR SMOKE
DAMPER
GREENHECK
SMD-201 10" X 12" 2 HONEYWELL MS4104F1010 120 / 1 / 60
DDC POINTS LIST:
HEAT PUMP (HP-1 AND HP-2) CONTROL DIAGRAM:
EQUIVALENT MANUFACTURES:
1. RUSKIN, POTTORFF, NAILOR
A
PP
R O
VE
D
A R
C H
IT
EC
TU
R
A L
M
EC
H A
N
IC
A L
EL
EC
TR
IC
A L
PL
U
M B
IN
G
R
EV
D A
TE
B
Y D
ES
C
R
IP
TI
O
N
DWN BY
SHEET OF
PROJECT NUMBER
I N D
AI
N
HEALTH
SERVI C
E
P H S -
KEY PLAN
N.T.S.
D
EP
A R
TM
EN
T O
F H
EA
LT
H
ED
U
C A
TI
O
N , A
N D
W
EL
FA
R
E O
FF
IC
E O
F
FA
C
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
A N
D
PR
O
PE
R
TY
M A
N A
G
EM
EN
T
R
EG
IO
N
A L
O
FF
IC
E
O F
FA
C
IL
IT
IE
S
EN
G
IN
EE
R
IN
G A
N D
C O
N
ST
R U
C
TI
O N
STAMP
DATE
SCALE
CKD BY
KEYED NOTES
GENERAL NOTES
EL
EC
TR
IC
AL
L
IG
H
TI
N
G P
LA
N
E-3
ELECTRICAL LIGHTING PLAN1
ELECTRICAL LIGHTING PLAN2
File details come from the government source that posted it. Updated .