Attachment II QAPS.pdf
PDF 7 MB Posted
- Solicitation number
- SPE603-26-R-0508
- Issued by
-
Defense Logistics Agency Energy
About this file
This document is a Supplemental Quality Assurance Provision (SQAP) for DLA Energy contracts covering multiple quality control and inspection requirements across various product and service categories.
The SQAP establishes contractor responsibilities for government inspections of services at contractor facilities, quality control plan requirements including receiving, blending, sampling, testing, storage, handling, loading, shipping, and calibration procedures. ENERGY QAP E11 mandates contractors prepare Quality Control Plans in triplicate submitted to the Contracting Officer and Quality Assurance Representative for approval prior to first receipt of government-owned product. ENERGY QAP E18 addresses inspection and cleaning of bulk petroleum storage tanks with specific frequencies: aviation fuel storage tanks require cleaning every 4-8 years depending on tank coating and inlet-filter configuration; ground and marine fuel storage tanks require cleaning when sample analysis indicates sediment buildup. Contractors must maintain historical data on each tank including construction date, service history, repair records, dimensions, and inspection schedules. ENERGY QAP E22, effective February 2022, establishes geographic inspection office assignments and office codes for DLA Energy contracts across continental United States (Code 110, 120), Alaska (Code 130), Hawaii, Europe/Africa (Code 200), and Indo-Pacific regions (Code 300), with detailed contact information for each regional quality manager. ENERGY QAP E28, effective February 2022, specifies contractor inspection responsibilities for storage operations including sampling per ASTM D4057, sample retention periods ranging from 15 to 90 days depending on shipment method, and routine testing procedures for water presence, density, temperature, appearance, color, flash point, fuel system icing inhibitor content, and electrical conductivity. ENERGY QAP E35 addresses nonconforming supplies and services, defining procedures for deviations and waivers with administrative cost thresholds of $500 minimum consideration and $1,000 contract modification requirements for cost impacts exceeding $1,000.
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Attachment II - QASP
SUPPLEMENTAL QUALITY ASSURANCE PROVISION (SQAP)
REVISIONS
REV DESCRIPTION DATE APPROVED
ENERGY QAP E28 February 2022
E28 CONTRACTOR INSPECTION RESPONSIBILITIES (STORAGE)
(a) Inspection and tests by the Government of services, facilities, and equipment specified within this contract does not relieve the Contractor from responsibility to meet all requirements of the contract.
(b) The Contractor shall furnish personnel, facilities, and equipment on-site to accomplish the following routine tests and procedures. These on-site resources may be provided by Contractor personnel or by a commercial source action on behalf of the Contractor. The Quality Representative will not be responsible for performing any of these services for the Contractor.
(1) Sampling of storage tanks, shipments and receipts in accordance with ASTM D4057, Standard Practice for Manual Sampling of Petroleum and Petroleum Products (API Manual of Petroleum Measurement Standards (MPMS), Chapter 8.1);
(2) Retaining of product composite samples from shipments and receipts as follows:
MINIMUM
METHOD OF SHIPMENT MINIMUM QUANTITY RETENTION PERIOD
Pipeline 20 liters 60 days
Tanker/Barge Parcel Composite 20 liters 90 days
Each compartment 0.5 liters 90 days
Navy Fleet Oilers/Vessels 10 liters 60 days
Tank Truck/Car 1 liter 15 days
NOTE: After the minimum retention period, samples shall be tested for Appearance, Color (Visual), API Gravity/Density and Flash Point and, if found to be on-specification, shall be returned to like Government stock on-site. Sample containers may be reused if properly cleaned.
(3) Determining the presence of water in storage tanks, shipments and receipts. Ensure that accurate water cuts are obtained by means of a water indicating paste conforming to MIL-W-83779B. Two suggested sources are Stewart Hall Chemical Testmaster Water Indicating Paste or Sartomer
Sar Gel Water Indicating Paste (see Note 2 below);
(4) Determining Density at 15 degrees Celsius or API gravity of products by ASTM D1298 or ASTM D4052 (see Note 2 below);
(5) Determining the temperature of products by the API MPMS, Chapter 7 (see Note 2 below);
(6) Determining the Appearance of applicable products using ASTM D4176, Procedure l (see Note 2 below);
(7) Determining the visual color of products.
(8) Determining the Flash Point of applicable products using test methods cited in the appropriate product specification (see Note 2 below);
(9) Conversion of gross to net gallonage (liters);
(10) Determining the percentage (volume) of fuel system icing inhibitor (FSII) by means of a portable refractometer in accordance with ASTM D
5006. One suggested source is H.B. Industries, Inc., Glenview, IL 60025 (B/2 Anti-Icing Additive test kit) (see Note 2 below); and
(11) Determining the range of fuel electrical conductivity using ASTM D2624. One suggested source for a conductivity meter is Emcee
Electronics, Inc., Sarasota, FL 33581 (Model 1152) (see Note 2 below)
SUPPLEMENTAL QUALITY ASSURANCE PROVISION (SQAP)
DEFENSE ENERGY SUPPORT CENTER
8725 JOHN J. KINGMAN RD
FORT BELVOIR, VIRGINIA 22060-6222
DISTRIBUTION PREPARED BY DATE ITEM
STATEMENT -A ENERGY QAP E28
APPROVED FOR REVIEWED BY DATE NSN CODE IDNO.
PUBLIC RELEASE MULTIPLE 52838
DISTRIBUTION IS APPROVED BY DATE SIZE SCALE DRAWING NUMBER
"UNLIMITED"
DLA FORM 1889, OCT 2011 PREVIOUS EDITION IS USABLE Add Continuation Page SHEET 1 OF 2 PDF(DLA)
SUPPLEMENTAL QUALITY ASSURANCE PROVISION (SQAP)
REVISIONS
REV DESCRIPTION DATE APPROVED
ENERGY QAP E28 February 2022
Note 1: All costs for providing the above tests and procedures shall be included in the monthly service charge. The only exception to the
Contractor's obligation to provide these services as part of the monthly service charge is when the tests described above are part of the higher order analysis (defined as the following categories: Composite Samples, Storage Tanks After Receipt, Interface Mixtures, Dormant
Stocks and Individual Tests (including particulate contamination) found in the MIL-STD-3004-1 Table titled MINIMUM SAMPLING AND
TESTING REQUIREMENTS FOR PETROLEUM PRODUCTS.
Note 2: Upon request, the Contractor shall permit the Quality Representative unrestricted use of the equipment and ancillary supplies needed to perform this test/procedure on behalf of the Government.
(c) During the contract, the Contractor shall furnish representative samples of the product in each storage tank, shipment or receipt at the request of, and in the manner and to the place designated by, the Quality Representative. Sample size will be 2 gallons for gasoline-type fuels and one gallon or 10 gallons for jet diesel-type fuels. The number of samples to be furnished during any 12-month period shall not exceed eight times the number of tanks specified in the contract. Such samples shall be packed, marked, and shipped by the Contractor, shipping expense prepaid, in containers and shipping boxes furnished by the Contractor. Sample containers shall be epoxy coated on the interior. This requirement is in addition to sampling required elsewhere in this contract provision and the contract. All reasonable direct shipping costs associated with samples required by this paragraph shall be reimbursed upon request from the Contractor and such costs shall not be included in the monthly service charge.
However, all other costs related to this requirement shall be included as part of the monthly service charge.
SUPPLEMENTAL QUALITY ASSURANCE PROVISION
(SOAP)
DEFENSE ENERGY SUPPORT CENTER
8725 JOHN J. KINGMAN RD
FORT BELVOIR, VIRGINIA 22060-6222
DISTRIBUTION STATEMENT -A
APPROVED FOR PUBLIC RELEASE
DISTRIBUTION IS "UNLIMITED"
SIZE SCALE CODE IDNO.
52838
DRAWING NUMBER
DLA FORM 1889, OCT 2011 PREVIOUS EDITION IS USABLE Add Continuation Page SHEET 2 OF 2 PDF(DLA)