A

12345678910111213

B

C

D

E

F

G

H

ODA

IPPM

PCR

EXTRACTION

TENANT

F OFFICE

TENANT

F

WAREHOUSE

STORAGE

TENANT

F STOR.

1 TENANT

F STOR.

TENANT

F CONF.

TENANT

F ENTRY

VESTIBULE

TENANT

F IDF

O&M

WORKSHOP

STORAGE

BREAK

ROOM

O&M

TOUCH

DOWN

AREA

IDF

JAN. UNISEX

TOILETVESTIBULE

ELEC. ELEC.

FIRE

PUMP

O&M

PRIVATE

OFFICE

O&M

LAUND.

SHARED

BREAK

ROOM

O&M

CONF.

MED.

CONF.

SML.

CONF.

UNASGD

OPEN

OFFICE

PHONE PHONE

ALCOVE

UNASGD

OPEN

OFFICE

MED.

CONF.

SML.

CONF.

UNASGD

OPEN

OFFICE

ODA RLS

OPEN

MED.

CONF.

MED.

CONF.

SML.

CONF.

COPY/WORK

SML.

CONF.

AMENITY

AMENITY

PHONEPHONE

MED.

CONF.

SML.

CONF.

PHONE

PHONE

BREAKOUT

ODA RLS

OPEN

OFFICE

ODA RLS

MED.

CONF

MED.

CONF.

BREAKOUT

WOMEN'S MEN'S

JAN.

AISLE

ELEV.

MACH.RM.

MEN'S

WOMEN'S

JAN.

PHONE PHONE PHONE PHONE

LOCKERS

STOR.

KITCH.

BIKE

STOR.

VEND.

AISLE

OSHA

OPEN

OFFICE

MED.

CONF.

LRG

CONF.

SML.

CONF.

SML.

CONF.

COFFEE

UNISEX UNISEX

SML.

CONF.

ALCOVE

PHONEPHONE

SML.

CONF.

MED.

CONF.

ODA PHL

OPEN

OFFICE

MED.

CONF.

ALCOVE ALCOVE

SML.

CONF.

PHONE PHONE

MULTI-

PURPOSE

MAIN

ENTRY

LOBBY

SHARED

SAMPLE

INTAKE/MAIL

ROOM

TENANT

F BULKY

ITEM

STOR.

TENANT

F BIKE

STOR.

TENANT

F

WALK-IN

REF.

TENANT

F

WALK-IN

FREEZER

TENANT

F UNISEX

TENANT

F OFFICETENANT

F COPY/

WORK

MEN'S

WOMEN'S

JAN.

ODA PHL

- SEED

STOR.

SHARED

LAB

STOR.SHARED

LAB

STOR.

STOR.

STOR./

WT HTR

AISLE

COPY

ODA AHL

LAB

VESTIBULE

NODE 3

NODE 4

NODE 5

NODE 2

NODE 1B

O&M

TEAM

OFFICE

AREA

MPOE

ODA PHL

NEMATODE

UNASGD

LER

SHARED

GLASSWARE

WASHING

SHARED

GLASSWARE

WASHING

SUPPORT

SHARED

MEDIA

PREP

SHARED

COLD

ROOM

(KIT/REAGENT)

ODA PHL

PCR

INST. RM.

ODA PHL

TEMPLATE

UNASGD.

STOR.

ODA PHL

REAG.PREP

ODA

IPPM

OFFICE /

HOTEL

STAT.

UNASGD

IDF

SHARED

CHEMICAL

STORAGE

SHARED

BALANCE

ROOM

ODA RLS

PCR INST

RM ODA RLS

TEMPLATE

UNASGD

ODA RLS

MICRO

LAB

ODA AHL

FUME

HOOD

ALCOVE

ODA AHL

PCR

ROOM

ODA AHL

TEMPLT.

OSHA

X-RAY

DIFFRACT.

ODA AHL

REAGENT

PREP

ODA AHL

JITUNASGND

STORAGE

ODA RLS

CHEM

LAB

CYL CL

CYL CL

OSHA

FUME

HOOD

ALCOVE

OSHA

MICRO-

SCOPY

OSHA

FIELD

EQUIP.

STOR./CAL./REPAIR

SHARED

PERCHL.

ACID

ROOM

OSHA JIT

ODA RLS

JIT

STORAGE ODA RLS

SAMPLE

PREP

STOR. /

FUTURE

TENANT

ODA

IPPM

TRAP

UNLOAD

/ SORT /

PROCESS

CLEANING

SHARED

TRASH /

RECYCLING

SHARED

CUSTOMER

RECEIVING

MEN'S

WOMEN'S

SHARED

BIO

WASTE

SHARED

CHEM

WASTE

ODA

IPPM

IMAGING

ODA

IPPM JIT

ODA RLS

ORGANIC

EXTRACTIONS

ALCOVE

ODA RLS

INORGANIC

EXTRACTIONS

ALCOVE

OSHA

LER

ODA AHL

LER

LID

ACCS RM

ODA PHL

SAMPLE

PREP &

SEED

LAB

ODA

IPPM

MUSEUM

ODA

IPPM

LER

ODA

IPPM

WORK 1

ODA

IPPM

INTAKE

ODA

IPPM

WORK 2

ODA

IPPM

WORK 3

ODA

IPPM

WASHRM.

ODA

IPPM

VEST. 2

ODA

IPPM

VEST. 1

ODA

IPPM

REARING

ROOM

ODA

IPPM

PCR

ODA

IPPM

LER

ODA

IPPM

GROW

ROOMODA

IPPM

MEDIA

STOR. ODA PHL

JIT

ODA PHL

FUME

HOOD

ALC.

MECHANICAL

ROOM &

MEZZANINE

EMERGENCY

RESPONSE

ODA

IPPM

BULLPEN

ODA PHL

- LER

ODA PHL

OPEN

OFFICE

ODA

IPPM

OPEN

OFFICE

SHARED

FRZR RM

(SAMP.)ODA AHL

OPEN

OFFICE

EMERGENCY

ELECTRICAL

ROOM

UNISEX

UNISEX

UNISEX

UNISEX

ATTIC

STOCK

STOR.

SHARED

SOUND

ROOM

ODA RLS

ANIMAL

ROOM

CYL CL

CYL CL

O&M

WORKSHOP

- SHELL

SPACE

OSHA

LAB

ODA

IPPM

STOR.

ODA PHL

MOLECULAR

BIOLOGY

LAB

UNASGD

LER

UNASGD

LER

ODA RLS

LER

ODA RLS

REAGENT

PREP

ODA RLS

FUME

HOOD

ALCOVE

IDF

LID

ACCS RM

SHARED

MEDIA

PREP

SUPPORT

ODA

IPPM

ENTOMOLOGY

LAB

ODA

IPPM

SAMPLE

PROCESSING

ODA AHL

STOR.

O&M

STOR.

ODA RLS

STOR.

ODA PHL

STOR.

ODA

IPPM

CLEAN

TRAP

STOR.

ODA PHL

ANTI

ROOM

TENANT

F LOW

STORAGE

STAIR 2

MOTHERS

RM.

WELLNESS

RM.

UNASGD

SHARED

LOADING

DOCK /

MARSHALLING

H A

L L

W A

Y

H A

L L

W A

Y

HALLWAY

A

IS

L E

ALCOVE

MECH.

ROOM

SHARED

COLD

ROOM

(SAMP.)

HALLWAY

HALLWAY

P.V.

EQUIP. /

ELEC.

ROOMSHARED

SAMPLE

PROCESSING

ROOM

OSHA

CAGE 1 STOR.

H A

L L

W A

Y

ODA

IPPM

ACF

GROW

ROOM

NODE 1A

H A

L L

W A

Y

H A

L L

W A

Y

H A

L L

W A

Y

STOR.

ARCHITECTURE

URBAN DESIGN + PLANNING

INTERIOR DESIGN

PORTLAND|OAKLAND

SERADESIGN.COM

CHECKED BY:

ISSUE DATE:

PROJECT NO:

REVISIONS

S E

R A

D es ig n an d

A rc hi te ct ur e, In c.

C o p y ri g h t p ro te c te d

S e e D e s ig n A g re e m e n t.

F o r u s e o n t h is p ro je c t o n ly

U n a u th o ri z e d r e p ro d u c ti o n o f a n y p a rt o f th is m a te ri a l is p ro h ib it e d

/1 /2

:4

:4

P M

IS

S

U E

F O

R C

O N

S T

R U

C T

IO

N

N o rt h

V a ll e y C o m p le x R e n o v a ti o n

D e p a rt m e n t o f A d m in is tr a ti v e S e rv ic e s

S

W th

A v e n u e

W ils o n v ill e O re g o n

M101

Checker 11.18.2021

1901010

FLOOR PLAN -

LEVEL 01 - HVAC

V O

L U

M E

1" = 20'-0"1

OVERALL FLOOR PLAN - LEVEL 01 - HVAC

KEYPLAN

A B C

D E F

9 5

E

GENERAL NOTES:

A. GENERAL NOTES ON THIS PAGE APPLY TO ALL SECTOR PLANS FOR THIS FLOOR.

B. COORDINATE ALL WORK WITH ALL TRADES INVOLVED. PROVIDE ADDITIONAL OFFSETS IN PIPING AND DUCTWORK

AND TRANSITIONS AROUND OBSTRUCTIONS AT NO ADDITIONAL COST TO THE OWNER.

C. VERIFY ALL EQUIPMENT CONNECTIONS WITH MANUFACTURER'S CERTIFIED DRAWINGS. VERIFY AND PROVIDE DUCT AND PIPING TRANSITIONS TO FURNISHED EQUIPMENT. FIELD VERIFY AND COORDINATE ALL DIMENSIONS

BEFORE FABRICATION.

D. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATIONS AND TYPE OF AIR DEVICES FOR

ALL SPACE FOR DISTRIBUTION INTENT.

E. ALL DETAILS APPLY TO THIS SHEET WHETHER TAGGED OR NOT.

F. PROVIDE VOLUME DAMPER AT EACH BRANCH OUTLET AND INLET WHERE REQUIRED FOR BALANCING OF THE

SYSTEM.

G. PROVIDE DUCTWORK TRANSITIONS AND ACCESSORIES AS REQUIRED TO CONNECT TO LABORATORY EXHAUSTED EQUIPMENT SPECIFIED UNDER DIVISION 11. REFER TO LAB FURNISHING DRAWINGS FOR EXACT LOCATIONS AND REQUIREMENTS OF EXHAUSTED DEVICES. REFER TO SPECIFICATIONS FOR DUCT CONSTRUCTION REQUIREMENTS.

H. PIPING SHALL BE THE LARGEST SIZE SHOWN UNTIL SMALLER PIPING SIZE IS INDICATED INCLUDING MAINS AND

BRANCH PIPING.

I. BRANCH RUNOUT PIPING TO TERMINAL DEVICES INCLUDING, BUT NOT LIMITED TO TERMINAL UNITS, DUCT- MOUNTED COILS, AND FAN COIL UNITS SHALL BE 3/4-INCH UNLESS OTHERWISE NOTED ON PLANS OR

SCHEDULES.

.19.

damiller Cloud+ damiller Cloud+ Mechanical Room. Work Location