Attachment H - dwg20of24.pdf
PDF 20 MB Posted
- Solicitation number
- N6247023R0005
View the file
Other files
Show all 40
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SM
D
C
B
1 2 3 4 5
NOT TO SCALE
1568016
DWG
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.
SCALE:
N62470-23-C-XXXX
RICHARD L STEPHENS, P.E.
LMM/MWL
CHIEF ENG/ARCH
DES DRW CHK
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
S O
U D
A B
A
YA
DRAWFORM REVISION: 25 AUGUST 2020
1 2 3 4 5
D
C
B
A
UNCLASSIFIED
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
A T
L A
N T
IC
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
N O
R F
O L K
V
A L A
N T
C A
P
IT
A L I M
P R
O V
E M
E N
T S
BRANCH MANAGER
PM/DM
SATISFACTORY TO DATE
FIRE PROTECTION DPS (DOUG STULTZ)
SEK (SOLVEIGH KEENE)
/3
/2
:1 :4
A
M
C R e v it L o c a l_ M o d e ls \2
\P
-1
-T R d ia n e .r io s E
Z M
N
.r v t
03/31/2023
T-001
MA DR JH
P J
O
IN
T M
O B
IL
IT
Y P
R O
C E
S S
IN
G
F A
C
IL
IT
Y
S O
U D
A B
A Y
G
R E
E C
E
G E
N E
R A
L N
O T
E S
A N
D A
B B
R E
V
IA
T
IO
N S
S H
E E
T
O F
14068905
T -0
Γ Ε
Ν
ΙΚ
Ε Σ
Σ Η
Μ Ε
ΙΩ
Σ
Ε
ΙΣ
Κ Α
Ι Σ
Υ Ν
Τ Μ
Η Σ
Ε
ΙΣ
Σ Χ
Ε Δ
ΙΟ
Α
Π Ο
TELECOMMUNICATIONS GENERAL NOTES
ΓΕΝΙΚΕΣ ΠΑΡΑΤΗΡΗΣΕΙΣ ΤΗΛΕΠΙΚOΙΝΩΝΙΩΝ
A THIS IS A STANDARD LEGEND SHEET. SOME SYMBOLS OR ABBREVIATIONS MAY APPEAR ON THIS SHEET AND NOT
ON THE PROJECT DRAWINGS.
ΑΥΤΟ ΕΙΝΑΙ ΕΝΑ ΠΡΟΤΥΠΟ ΣΧΕΔΙΟ ΥΠΟΜΝΗΜΑΤΟΣ. ΜΕΡΙΚΑ ΣΥΜΒΟΛΑ Η' ΣΥΝΤΜΗΣΕΙΣ ΜΠΟΡΕΙ ΝΑ ΕΜΦΑΝΙΖΟΝΤΑΙ ΣΕ
ΑΥΤΟ ΤΟ ΣΧΕΔΙΟ ΚΑΙ ΟΧΙ ΣΤΑ ΣΧΕΔΙΑ ΤΟΥ ΕΡΓΟΥ.
B ROUTE AND TERMINATE HORIZONTAL DATA AND VOICE CABLES TO THE NEAREST FLOOR SERVING TELECOMMUNICATION ROOM. FULLY TERMINATE CABLES AS SPECIFIED ON THE DRAWING. LEAVE NO GAPS IN THE
NUMBERING SEQUENCE, UNLESS INDICATED AND VERIFIED BY THE ENGINEER.
ΔΡΟΜΟΛΟΓΗΣΤΕ ΚΑΙ ΤΕΡΜΑΤΙΣΤΕ ΟΡΙΖΟΝΤΙΑΣ ΔΙΑΝΟΜΗΣ ΚΑΛΩΔΙΑ ΔΕΔΟΜΕΝΩΝ ΚΑΙ ΦΩΝΗΣ ΣΤΟ ΠΛΗΣΙΕΣΤΕΡΟ ΔΩΜΑΤΙΟ ΤΗΛΕΠΙΚΟΙΝΩΝΙΩΝ ΠΟΥ ΕΞΥΠΗΡΕΤΕΙ ΤΟΝ ΟΡΟΦΟ.ΤΕΡΜΑΤΙΣΤΕ ΠΛΗΡΩΣ ΤΑ ΚΑΛΩΔΙΑ ΟΠΩΣ ΠΡΟΔΙΑΓΡΑΦΟΝΤΑΙ ΣΤΑ ΣΧΕΔΙΑ.ΜΗΝ ΑΦΗΝΕΤΕ ΚΕΝΑ ΣΤΗΝ ΑΥΞΟΝΤΑ ΑΡΙΘΜΗΣΗ ΕΚΤΟΣ ΑΝ ΥΠΟΔΕΙΚΝΥΕΤΑΙ ΚΑΙ
ΕΠΙΒΕΒΑΙΩΝΕΤΑΙ ΑΠΟ ΤΟΝ ΜΗΧΑΝΙΚΟ.
C PROVIDE A 3-METER COIL OF HORIZONTAL CABLE IN CEILING AT EACH HORIZONTAL OUTLET LOCATIONS EXCEPT WHERE ADDED LENGTH CAUSES PERMANENT LINK TO EXCEED 90-METER. COIL CABLE IN A FIGURE-8 OR OBLONG
CIRCLE TO PREVENT EMI INTERFERENCE.
ΠΡΟΜΗΘΕΥΣΤΕ 3 ΜΕΤΡΑ ΕΠΙΠΛΕΟΝ ΚΑΛΩΔΙΟΥ ΟΡΙΖΟΝΤΙΑΣ ΔΙΑΝΟΜΗΣ ΣΤΗΝ ΟΡΟΦΗ ΣΕ ΚΑΘΕ ΣΗΜΕΙΟ ΛΗΨΗΣ ΟΡΙΖΟΝΤΙΑΣ ΔΙΑΝΟΜΗΣ ΕΚΤΟΣ ΑΝ ΤΟ ΕΠΙΠΛΕΟΝ ΜΗΚΟΣ ΟΔΗΓΕΙ ΣΕ ΜΟΝΙΜΗ ΣΥΝΔΕΣΗ ΠΟΥ ΞΕΠΕΡΝΑ ΤΑ 90 ΜΕΤΡΑ.
ΕΠΙΠΛΕΟΝ ΚΑΛΩΔΙΟ ΣΕ ΣΧΗΜΑ 8 Η' ΣΕ ΕΠΙΜΗΚΗ ΚΥΚΛΟ ΓΙΑ ΑΠΟΦΥΓΗ ΗΛΕΚΤΡΟΜΑΓΝΗΤΙΚΩΝ ΠΑΡΕΜΒΟΛΩΝ.
D VERIFY THAT THE TOTAL DISTANCE FROM DATA OUTLET TO PATCH PANEL DOES NOT EXCEED 90 METERS BEFORE PLACING CABLES. SUBMIT FOR DESIGN CLARIFICATION IF CABLE LENGTH WILL EXCEED 90 METERS.
ΕΠΑΛΗΘΕΥΣΤΕ ΟΤΙ Η ΣΥΝΟΛΙΚΗ ΑΠΟΣΤΑΣΗ ΑΠΟ ΤΗΝ ΤΕΡΜΑΤΙΚΗ ΠΡΙΖΑ ΔΕΔΟΜΕΝΩΝ ΜΕΧΡΙ ΤΟΝ ΠΙΝΑΚΑ ΜΙΚΤΟΝΟΜΙΣΗΣ ΔΕΝ ΥΠΕΡΒΑΙΝΕΙ ΤΑ 90 ΜΕΤΡΑ ΠΡΙΝ ΑΠΟ ΤΗΝ ΤΟΠΟΘΕΤΗΣΗ ΚΑΛΩΔΙΩΝ. ΥΠΟΒΑΛΛΕΤΕ ΓΙΑ
ΔΙΕΥΚΡΙΝΙΣΗ ΣΧΕΔΙΑΣΜΟΥ ΕΑΝ ΤΟ ΜΗΚΟΣ ΚΑΛΩΔΙΟΥ ΞΕΠΕΡΝΑΕΙ ΤΑ 90 ΜΕΤΡA.
E PROVIDE CABLE MANUFACTURER APPROVED FANOUT KIT FOR THE DIRECT TERMINATION OF GEL FILLED, LOOSE
TUBE, FIBER OPTIC CABLES ONLY. USE FUSION SPLICE METHOD WHENEVER POSSIBLE.
ΠΡΟΜΗΘΕΥΣΤΕ ΕΓΚΕΚΡΙΜΕΝΟ ΕΞΑΡΤΗΜΑ (FANOUT KIT) ΑΠΟ ΤΟΝ ΚΑΤΑΣΚΕΥΑΣΤΗ ΚΑΛΩΔΙΩΝ ΜΟΝΟ ΓΙΑ ΤΟΝ ΑΠΕΥΘΕΙΑΣ ΤΕΡΜΑΤΙΣΜΟ ΚΑΛΩΔΙΟΥ ΟΠΤΙΚΗΣ ΙΝΑΣ ΜΕ ΕΠΙΚΑΛΥΨΗ ΓΕΛΗΣ ΕΛΕΥΘΕΡΟΥ ΣΩΛΗΝΑ. ΧΡΗΣΙΜΟΠΟΙΗΣΤΕ
ΤΗΝ ΜΕΘΟΔΟ ΣΥΓΚΟΛΛΗΣΗΣ ΤΗΞΗΣ ΟΠΟΤΕΔΗΠΟΤΕ ΕΙΝΑΙ ΔΥΝΑΤΟΝ.
F PROVIDE CABLE TERMINATIONS INCLUDING CONNECTORS, COUPLERS, FDU’S, PATCH PANELS, STRESS RELIEF, AND
WIRE MANAGEMENT ACCORDING TO THE STANDARD DETAILS FOR EACH CABLE.
ΠΡΟΜΗΘΕΥΣΤΕ ΤΕΡΜΑΤΙΣΜΟΥΣ ΚΑΛΩΔΙΩΝ ΣΥΜΠΕΡΙΛΑΜΒΑΝΟΝΤΑΣ ΣΥΝΔΕΣΜΟΥΣ, ΖΕΥΚΤΕΣ, ΜΟΝΑΔΕΣ ΔΙΑΝΟΜΗΣ ΟΠΤΙΚΗΣ ΙΝΑΣ (FDU’S), ΠΙΝΑΚΕΣ ΜΙΚΤΟΝΟΜΙΣΗΣ, ΕΚΤΟΝΩΤΕΣ ΤΑΣΕΩΝ (STRESS RELIEF), ΚΑΙ ΔΙΑΧΕΙΡΙΣΤΕΣ
ΚΑΛΩΔΙΩΝ ΣΥΜΦΩΝΑ ΜΕ ΤΙΣ ΠΡΟΤΥΠΕΣ ΠΡΟΔΙΑΓΡΑΦΕΣ ΚΑΘΕ ΚΑΛΩΔΙΟΥ.
G COMMUNICATION PATHWAYS AND OUTLETS ARE SHOWN DIAGRAMMATICALLY. LOCATIONS ARE APPROXIMATE UNLESS DIMENSIONED. FIELD COORDINATE WORK WITH ARCHITECTURAL, POWER/LIGHTING, MECHANICAL, FURNITURE CONTRACTOR, AND OTHERS PRIOR TO INSTALLATION.
ΟΙ ΟΔΕΥΣΕΙΣ ΚΑΙ ΟΙ ΕΞΟΔΟΙ ΤΩΝ ΤΗΛΕΠΙΚΟΙΝΩΝΙΩΝ ΠΑΡΟΥΣΙΑΖΟΝΤΑΙ ΔΙΑΓΡΑΜΜΑΤΙΚΑ. ΟΙ ΘΕΣΕΙΣ ΕΙΝΑΙ ΚΑΤΑ ΠΡΟΣΕΓΓΙΣΗ ΕΚΤΟΣ ΑΝ ΔΙΑΣΤΑΣΙΟΛΟΓΟΥΝΤΑΙ. ΣΥΝΤΟΝΙΣΜΟΣ ΕΡΓΟΥ ΣΤΟ ΠΕΔΙΟ ΣΥΜΦΩΝΑ ΜΕ ΑΡΧΙΤΕΚΤΟΝΙΚΑ, ΙΣΧΥΡΑ/ ΦΩΤΙΣΜΟΥ, ΜΗΧΑΝΟΛΟΓΙΚΑ, ΕΡΓΟΛΑΒΟ ΕΠΙΠΛΩΣΗΣ, ΚΑΙ ΑΛΛΟΥΣ ΠΡΙΝ ΑΠΟ ΤΗΝ ΕΓΚΑΤΑΣΤΑΣΗ.
H COORDINATE FINAL MOUNTING OF THE DATA OUTLETS IN THE OPEN OFFICE CUBICLES WITH THE FURNITURE
INSTALLER.
ΣΥΝΤΟΝΙΣΤΕ ΤΗΝ ΤΕΛΙΚΗ ΤΟΠΟΘΕΤΗΣΗ ΤΩΝ ΛΗΨΕΩΝ ΔΕΔΟΜΕΝΩΝ ΣΤΙΣ ΚΑΜΠΙΝΕΣ ΤΩΝ ΑΝΟΙΚΤΩΝ ΓΡΑΦΕΙΩΝ ΜΕ
ΤΟΝ ΕΓΚΑΤΑΣΤΑΤΗ ΤΩΝ ΕΠΙΠΛΩΝ.
J PROVIDE NECESSARY CABLE, SUPPORTS, AND HARDWARE FOR A COMPLETE AND OPERABLE NETWORK CABLING
SYSTEM.
ΠΡΟΜΗΘΕΥΣΤΕ ΤΗΝ ΑΠΑΡΑΙΤΗΤΗ ΚΑΛΩΔΙΩΣΗ, ΣΤΗΡΙΞΗ, ΚΑΙ ΤΟ ΥΛΙΚΟ ΓΙΑ ΕΝΑ ΟΛΟΚΛΗΡΩΜΕΝΟ ΚΑΙ ΛΕΙΤΟΥΡΓΙΚΟ
ΣΥΣΤΗΜΑ ΚΑΛΩΔΙΩΣΕΩΝ ΔΙΚΤΥΟΥ.
K TELECOMMUNICATIONS INFRASTRUCTURE AND ELECTRONIC SECURITY MUST BE INSTALLED IN ACCORDANCE WITH THE SPECIFICIATIONS DEFINED IN THE FOLLOWING DIVISION 27, DIVISION 28, AND DIVISION 33 SPECIFICATIONS.
Η ΤΗΛΕΠΙΚΟΙΝΩΝΙΑΚΗ ΥΠΟΔΟΜΗ ΚΑΙ Η ΗΛΕΚΤΡΟΝΙΚΗ ΑΣΦΑΛΕΙΑ ΠΡΕΠΕΙ ΝΑ ΕΓΚΑΤΑΣΤΑΘΕΙ ΣΥΜΦΩΝΑ ΜΕ ΤΙΣ ΠΡΟΔΙΑΓΡΑΦΕΣ ΠΟΥ ΠΡΟΣΔΙΟΡΙΖΟΝΤΑΙ ΣΤΑ ΑΚΟΛΟΥΘΑ: ΤΟΜΕΑΣ 27,ΤΟΜΕΑΣ 28, ΚΑΙ ΤΟΜΕΑΣ 33 ΤΩΝ
ΠΡΟΔΙΑΓΡΑΦΩΝ.
L REFER TO SPECIFICATION 07 84 00 FOR FIRESTOP AND PENETRATIONS. USE RE-ENTERABLE FIRESTOP SYSTEMS FOR FIRE-RATED WALLS. SEE DRAWING T-505. PROVIDE MECHANICAL RE-ENTERABLE FIRESTOP SYSTEMS FOR TELECOMMUNICATION PATHWAYS ENTERING TR'S, INCLUDING TRAYS AND CONDUITS. SEE SITE DRAWING ES100.
ΑΝΑΤΡΕΞΤΕ ΣΤΗΝ ΠΡΟΔΙΑΓΡΑΦΗ 07 84 00 ΓΙΑ ΠΥΡΟΦΡΑΓΜΟΥΣ ΚΑΙ ΔΙΕΙΣΔΥΣΕΙΣ. ΧΡΗΣΙΜΟΠΟΙΗΣΤΕ ΕΠΑΝΑΠΡΟΣΒΑΣΙΜΑ ΣΥΣΤΗΜΑΤΑ ΠΥΡΟΦΡΑΓΜΩΝ ΓΙΑ ΠΥΡΑΝΤΟΧΟΥΣ ΤΟΙΧΟΥΣ. ΒΛΕΠΕ ΣΧΕΔΙΑ Τ-505. ΠΡΟΜΗΘΕΥΣΤΕ ΜΗΧΑΝΙΚΑ ΕΠΑΝΑΠΡΟΣΒΑΣΙΜΑ ΣΥΣΤΗΜΑΤΑ ΠΥΡΟΦΡΑΓΜΩΝ ΓΙΑ ΟΔΕΥΣΕΙΣ ΤΗΛΕΠΙΚΟΙΝΩΝΙΩΝ ΠΟΥ ΕΙΣΑΓΟΝΤΑΙ ΣΤΑ TR, ΣΥΜΠΕΡΙΛΑΜΒΑΝΟΜΕΝΩΝ ΤΩΝ ΣΧΑΡΩΝ ΚΑΙ ΤΩΝ ΣΩΛΗΝΩΝ. ΒΛΕΠΕ ΣΧΕΔΙΟ ΕΞΩΤΕΡΙΚΩΝ ΧΩΡΩΝ ES100.
M CAT6 CABLES FOR ETHERNET REQUIRE 90-METER OR LESS DISTANCE FROM OUTLET TO PATCH PANEL IN TELECOMMUNICATIONS ROOM. VALIDATE DISTANCE BEFORE PULLING CABLE TO ASSURE DISTANCE FROM TR IS
NOT OVER DISTANCE.
ΤΑ ΚΑΛΩΔΙΑ ΚΑΤΗΓΟΡΙΑΣ 6 ΓΙΑ ETHERNET ΑΠΑΙΤΟΥΝ 90 ΜΕΤΡΑ Ή ΜΙΚΡΟΤΕΡΗ ΑΠΟΣΤΑΣΗ ΑΠΟ ΤΗΝ ΛΗΨΗ ΕΩΣ ΤΟΝ ΠΙΝΑΚΑ ΜΙΚΤΟΝΟΜΗΣΗΣ ΣΤΟ ΔΩΜΑΤΙΟ ΤΗΛΕΠΙΚΟΙΝΩΝΙΩΝ. ΕΠΑΛΗΘΕΥΣΤΕ ΤΗΝ ΑΠΟΣΤΑΣΗ ΠΡΙΝ ΤΡΑΒΗΞΕΤΕ ΤΟ ΚΑΛΩΔΙΟ ΓΙΑ ΝΑ ΔΙΑΒΕΒΑΙΩΣΕΤΕ ΟΤΙ Η ΑΠΟΣΤΑΣΗ ΑΠΟ ΤΟ TR ΔΕΝ ΥΠΕΡΒΑΙΝΕΙ ΑΥΤΗ ΤΗΝ ΑΠΟΣΤΑΣΗ.
N PROVIDE TWO PATCH CABLES FOR EACH HORIZONTAL CABLE (ONE AT PATCH PANEL AND ONE AT WORK AREA OUTLET). PROVIDE ONE DUPLEX PATCH CORD PER DUPLEX FIBER BACKBONE PORT. PROVIDE PATCH CABLES FOR FIBER PATCH PANEL AT EACH END OF TERMINATION AND FOR EVERY PORT OF FIBER STRAND INSTALLED.
COORDINATE WITH CLIENT FOR LENGTHS AND END TYPES.
ΠΡΟΜΗΘΕΥΣΤΕ ΔΥΟ ΚΑΛΩΔΙΑ ΜΙΚΤΟΝΟΜΗΣΗΣ ΓΙΑ ΚΑΘΕ ΟΡΙΖΟΝΤΙΑ ΚΑΛΩΔΙΩΣΗ (ΕΝΑ ΣΤΟΝ ΠΙΝΑΚΑ ΜΙΚΤΟΝΟΜΗΣΗΣ ΚΑΙ ΕΝΑ ΣΤΗΝ ΛΗΨΗ ΤΗΣ ΘΕΣΗΣ ΕΡΓΑΣΙΑΣ). ΠΡΟΜΗΘΕΥΣΤΕ ΕΝΑ ΔΙΠΛΟ ΚΑΛΩΔΙΟ ΜΙΚΤΟΝΟΜΗΣΗΣ ΑΝΑ ΘΥΡΑ ΔΙΠΛΗΣ ΙΝΑΣ ΚΟΡΜΟΥ. ΠΡΟΜΗΘΕΥΣΤΕ ΚΑΛΩΔΙΑ ΜΙΚΤΟΝΟΜΗΣΗΣ ΓΙΑ ΠΙΝΑΚΑ ΜΙΚΤΟΝΟΜΗΣΗΣ ΙΝΩΝ ΣΕ ΚΑΘΕ ΑΚΡΟ ΤΩΝ ΤΕΡΜΑΤΙΣΜΩΝ ΚΑΙ ΓΙΑ ΚΑΘΕ ΘΥΡΑ ΙΝΑΣ ΠΟΥ ΓΙΝΕΤΑΙ ΕΓΚΑΤΑΣΤΑΣΗ. ΣΥΝΤΟΝΙΣΤΕ ΜΕ ΤΟΝ ΠΕΛΑΤΗ ΓΙΑ ΜΗΚΗ ΚΑΙ
ΤΥΠΟ ΤΕΡΜΑΤΙΣΜΟΥ.
TELECOMMUNICATIONS DIVISON NOTES
ΠΑΡΑΤΗΡΗΣΕΙΣ ΚΑΤΗΓΟΡΙΑΣ ΤΗΛΕΠΙΚΟΙΝΩΝΙΩΝ
DIV 27 COMMUNICATIONS
ΚΑΤΗΓΟΡΙΑ 27 ΕΠΙΚΟΙΝΩΝΙΩΝ
27 10 00 BUILDING TELECOMMUNICATIONS CABLING SYSTEM
ΣΥΣΤΗΜΑ ΚΑΛΩΔΙΩΣΗΣ ΤΗΛΕΠΙΚΟΙΝΩΝΙΩΝ ΚΤΙΡΙΟΥ
27 51 16 RADIO AND PUBLIC ADDRESS SYSTEMS
ΡΑΔΙΟΦΩΝΟΝΙΚΑ ΚΑΙ ΔΗΜΟΣΙΩΝ ΑΝΑΓΓΕΛΙΩΝ ΣΥΣΤΗΜΑΤΑ
DIV 33 UTILITIES
ΚΑΤΗΓΟΡΙΑ 33 ΚΟΙΝΗΣ
ΩΦΕΛΕΙΑΣ
33 82 00 TELECOMMUNICATIONS OUTSIDE PLANT (OSP)
ΕΞΩΤΕΡΙΚΑ ΔΙΚΤΥΑ ΤΗΛΕΠΙΚΟΙΝΩΝΙΩΝ (OSP)
TELECOMMUNICATIONS OUTSIDE PLANT NOTES
ΣΗΜΕΙΩΣΕΙΣ ΕΞΩΤΕΡΙΚΟΥ ΔΙΚΤΥΟΥ ΤΗΛ/ΝΙΩΝ
1 OUTSIDE PLANT (OSP) CABLING TO CONFORM TO THE SPECIFICATIONS DEFINED IN 33 82 00 AND THE
MANUFACTURER INSTALLATION GUIDELINES.
ΤΟ ΕΞΩΤΕΡΙΚΟ ΔΙΚΤΥΟ (OSP) ΚΑΛΩΔΙΩΣΕΩΝ ΠΡΕΠΕΙ ΝΑ ΣΥΜΜΟΡΦΩΝΕΤΑΙ ΜΕ ΤΙΣ ΠΡΟΔΙΑΓΡΑΦΕΣ ΠΟΥ
ΟΡΙΖΟΝΤΑΙ ΣΤΟ 33 82 00, ΚΑΙ ΤΙΣ ΟΔΗΓΙΕΣ ΕΓΚΑΤΑΣΤΑΣΗΣ ΤΟΥ ΚΑΤΑΣΚΕΥΑΣΤΗ.
2 FIBER OPTIC CABLE TO BE AN ALL DIELECTRIC, INDOOR/OUTDOOR RATED CABLE, TO ELIMINATE THE NEED FOR
A TRANSITION SPLICE IN THE ENTRANCE FACILITY.
ΤΟ ΚΑΛΩΔΙΟ ΟΠΤΙΚΩΝ ΙΝΩΝ ΠΡΕΠΕΙ ΝΑ ΕΙΝΑΙ ΠΛΗΡΩΣ ΔΙΗΛΕΚΤΡΙΚΟ, ΚΑΛΩΔΙΟ ΓΙΑ ΕΣΩΤΕΡΙΚΗ/ΕΞΩΤΕΡΙΚΗ
ΧΡΗΣΗ, ΓΙΑ ΕΞΑΛΕΙΨΗ ΤΗΣ ΑΝΑΓΚΗΣ ΜΕΤΑΒΑΤΙΚΗΣ ΕΝΩΣΗΣ ΣΤΗΝ ΕΙΣΟΔΟ ΤΗΣ ΕΓΚΑΤΑΣΤΑΣΗΣ.
3 OSP COPPER AND FIBER CABLES TO BE TAGGED UPON ENTRY AND EXIT OF A COMMUNICATIONS MAINTENANCE HOLE, HANDHOLE, OR SPLICE CASE. OSP CABLE TAGS WILL BE USED IN UNDERGROUND ENVIRONMENTS
DESIGNED FOR SUCH ENVIRONMENTS.
ΤΟ ΕΞΩΤΕΡΙΚΟ ΔΙΚΤΥΟ ΚΑΛΩΔΙΩΝ ΧΑΛΚΟΥ ΚΑΙ ΟΠΤΙΚΩΝ ΙΝΩΝ ΝΑ ΣΗΜΑΝΘΕΙ ΚΑΤΑ ΤΗΝ ΕΙΣΟΔΟ ΚΑΙ ΕΞΟΔΟ ΤΟΥ ΑΠΟ ΦΡΕΑΤΙΟ ΣΥΝΤΗΡΗΣΗΣ ΕΠΙΚΟΙΝΩΝΙΩΝ, ΧΕΙΡΟΘΥΡΙΔΑ Η ΚΟΥΤΙ ΕΝΩΣΕΩΣ. ΟΙ ΣΗΜΑΝΣΕΙΣ ΚΑΛΩΔΙΩΝ ΤΩΝ ΕΞΩΤΕΡΙΚΩΝ ΔΙΚΤΥΩΝ ΠΟΥ ΧΡΗΣΙΜΟΠΟΙΟΥΝΤΑΙ ΣΕ ΥΠΟΓΕΙΑ ΠΕΡΙΒΑΛΛΟΝΤΑ ΠΡΕΠΕΙ ΝΑ ΕΙΝΑΙ ΚΑΤΑΛΛΗΛΕΣ ΓΙΑ
ΤΕΤΟΙΑ ΠΕΡΙΒΑΛΛΟΝΤΑ.
4 OSP BACKBONE CABLES TO BE LOOPED AT LEAST ONCE IN THE EACH MAINTENANCE HOLE BEFORE ENTERING
A FACILITY.
ΤΑ ΚΑΛΩΔΙΑ ΤΟΥ ΕΞΩΤΕΡΙΚΟΥ ΔΙΚΤΥΟΥ ΚΟΡΜΟΥ ΠΡΕΠΕΙ ΝΑ ΣΧΗΜΑΤΙΖΟΥΝ ΤΟΥΛΑΧΙΣΤΟΝ ΕΝΑ ΒΡΟΓΧΟ ΣΕ ΚΑΘΕ
ΦΡΕΑΤΙΟ ΣΥΝΤΗΡΗΣΗΣ ΠΡΙΝ ΤΗΝ ΕΙΣΑΓΩΓΗ ΤΟΥΣ ΣΤΗΝ ΕΓΚΑΤΑΣΤΑΣΗ.
5 REFER TO ES100 AND ES101 FOR TELECOMMUNICATIONS SITE WORK.
ΑΝΑΤΡΕΞΤΕ ΣΤΑ ES100 KAI ES101 ΓΙΑ ΕΡΓΑΣΙΕΣ ΤΗΛΕΠΙΚΟΙΝΩΝΙΩΝ ΕΞΩΤΕΡΙΚΟΥ ΧΩΡΟΥ.
TELECOMMUNICATIONS PATHWAY NOTES
ΠΑΡΑΤΗΡΗΣΕΙΣ ΟΔΕΥΣΕΩΝ ΤΗΛΕΠΙΚΟΙΝΩΝΙΩΝ
1 MOUNT 300-MILLIMETER WIDE BY 100-MILLIMETER HIGH WIRE BASKET TRAY ABOVE THE CEILING IN THE AIR OPS BUILDING. CONDUIT WILL BE INSTALLED FROM THE BASKET TRAY TO EACH WAO.
ΤΟΠΟΘΕΤΗΣΤΕ ΣΧΑΡΑ ΚΑΛΩΔΙΩΝ ΣΥΡΜΑΤΙΝΟΥ ΠΛΕΓΜΑΤΟΣ ΠΛΑΤΟΥΣ 300mm ΕΠΙ 100 mm ΥΨΟΥΣ
ΠΑΝΩ ΑΠΟ ΤΗΝ ΨΕΥΔΟΡΟΦΗ ΣΤΟ ΚΤΙΡΙΟ AIR OPS. ΕΝΑΣ ΣΩΛΗΝΑΣ ΘΑ ΤΟΠΟΘΕΤΗΘΕΙ ΑΠΟ ΤΗΝ
ΣΧΑΡΑ ΣΥΡΜΑΤΙΝΟΥ ΠΛΕΓΜΑΤΟΣ ΣΕ ΚΑΘΕ ΠΡΙΖΑ ΧΩΡΟΥ ΕΡΓΑΣΙΑΣ (WAO).
2 MOUNT 300-MILLIMETER WIDE BY 100-MILLIMETER HIGH WIRE BASKET TRAY NEAR THE ROOF OF
THE CARGO BAY AT MOUNTING HEIGHTS AS INDICATED.
ΤΟΠΟΘΕΤΗΣΤΕ ΣΧΑΡΑ ΚΑΛΩΔΙΩΝ ΣΥΡΜΑΤΙΝΟΥ ΠΛΕΓΜΑΤΟΣ ΠΛΑΤΟΥΣ 300 ΧΙΛΙΟΣΤΩΝ ΕΠΙ 100
ΧΙΛΙΟΣΤΑ ΥΨΟΥΣ ΚΟΝΤΑ ΣΤΗΝ ΟΡΟΦΗ ΤΟΥ ΧΩΡΟΥ ΑΠΟΘΗΚΕΥΣΗΣ ΣΕ ΥΨΗ ΕΓΚΑΤΑΣΤΑΣΗΣ ΟΠΩΣ
ΥΠΟΔΕΙΚΝΥΕΤΑΙ.
3 PROVIDE THREE (3) 100mm CONDUITS FROM THE 1ST FLOOR CARGO AREA IDF-2 TO THE 1ST
FLOOR MDF FOR INTRABUILDING BACKBONE CABLING.
ΠΡΟΜΗΘΕΥΣΤΕ ΤΡΕΙΣ (3) ΣΩΛΗΝΕΣ ΤΩΝ 100mm ΑΠΟ ΤΗΝ ΠΕΡΙΟΧΗ ΕΜΠΟΡΕΥΜΑΤΩΝ ΤΟΥ 1ΟΥ ΠΑΤΩΜΑΤΟΣ IDF-2 ΜΕΧΡΙ ΤΟΝ ΧΩΡΟ TOY 1ΟΥ ΠΑΤΩΜΑΤΟΣ MDF ΓΙΑ ΚΑΛΩΔΙΩΣΗ ΔΙΚΤΥΟΥ ΚΟΡΜΟΥ
ΤΟΥ ΚΤΙΡΙΟΥ.
4 PROVIDE THREE (3) 100mm CONDUITS FROM THE 1ST FLOOR MDF-1 TO THE 2ND FLOOR IDF-1.
ΠΡΟΜΗΘΕΥΣΤΕ ΤΡΕΙΣ (3) ΣΩΛΗΝΕΣ ΤΩΝ 100mm ΑΠΟ ΤΟ MDF-1 ΤΟΥ 1ΟΥ ΠΑΤΩΜΑΤΟΣ ΜΕΧΡΙ ΤΟ
IDF-1 ΤΟΥ ΔΕΥΤΕΡΟΥ ΠΑΤΩΜΑΤΟΣ.
5 PROVIDE ONE (1) EACH 50mm CONDUIT FROM THE 2ND FLOOR IDF-1 TO THE SIPRNET WALL MOUNT
CABINET IN THE SIPR/NIPR ROOM 218 AND CONFERENCE ROOM 217.
ΠΡΟΜΗΘΕΥΣΤΕ ΑΠΟ ΕΝΑ (1) ΣΩΛΗΝΑ 50 mm ΑΠΟ ΤΟ IDF-1 ΤΟΥ ΔΕΥΤΕΡΟΥ ΠΑΤΩΜΑΤΟΣ ΣΤΗΝ
ΕΠΙΤΟΙΧΕΙΑ ΚΑΜΠΙΝΑ SIPRNET ΣΤΟΝ ΧΩΡΟ 218 SIPR/NIPR ΚΑΙ ΣΤΟΝ ΧΩΡΟ ΣΥΣΚΕΨΕΩΝ 217.
6 PROVIDE ONE (1) 25mm CONDUIT TO EACH WAO TO ALLOW FOR FUTURE EXPANSION TO CAT6A
CABLING. TERMINATE CONDUIT IN A DEEP WELL (100-MILLIMETER) SINGLE GANG BACK BOX
INSTALLED BY ELECTRICAL CONTRACTOR. PROVIDE BUSHINGS ON CONDUIT ENDS.
ΠΡΟΜΗΘΕΥΣΤΕ ΕΝΑ ΣΩΛΗΝΑ 25mm ΣΕ ΚΑΘΕ ΠΡΙΖΑ ΠΕΡΙΟΧΗΣ ΕΡΓΑΣΙΑΣ (WAO) ΓΙΑ ΝΑ ΕΠΙΤΡΕΨΕΤΕ
ΜΕΛΛΟΝΤΙΚΗ ΕΠΕΚΤΑΣΗ ΣΕ ΚΑΛΩΔΙΑ ΚΑΤΗΓΟΡΙΑΣ CAT6A. ΤΕΡΜΑΤΙΣΤΕ ΤΟΝ ΣΩΛΗΝΑ ΣΕ ΕΝΑ
ΕΝΤΟΙΧΙΣΜΕΝΟ ΚΟΥΤΙ ΜΙΑΣ ΘΕΣΗΣ ΜΕΓΑΛΟΥ ΒΑΘΟΥΣ (100 ΧΙΛΙΟΣΤΩΝ) ΕΓΚΑΤΕΣΤΗΜΕΝΟ ΑΠΟ ΤΟΝ
ΕΡΓΟΛΑΒΟ ΗΛΕΚΤΡΙΚΩΝ. ΠΡΟΜΗΘΕΥΣΤΕ ΠΡΟΣΤΑΤΕΥΤΙΚΑ ΣΤΑ ΑΚΡΑ ΤΟΥ ΣΩΛΗΝΑ.
7 PROVIDE ONE (1) 25mm CONDUIT FOR WALL PHONES.
ΠΡΟΜΗΘΕΥΣΤΕ ΕΝΑ (1) ΣΩΛΗΝΑ 25 mm ΓΙΑ ΤΙΣ ΕΠΙΤΟΙΧA ΤΗΛΕΦΩΝΑ.
8 PROVIDE TWO (2) 50mm CONDUIT TO FLOOR BOXES FOR VOICE/DATA CABLING. PROVIDE 50mm CONDUIT TO FLOOR BOXES FOR AUDIO VISUAL CABLING. PROVIDE ONE (1) SPARE 25mm CONDUIT.
ΠΡΟΜΗΘΕΥΣΤΕ ΔΥΟ (2) ΣΩΛΗΝΕΣ 50 mm ΣΤΑ ΚΟΥΤΙΑ ΔΑΠΕΔΟΥ ΓΙΑ ΚΑΛΩΔΙΩΣΗ ΦΩΝΗΣ/ΔΕΔΟΜΕΝΩΝ. ΠΡΟΜΗΘΕΥΣΤΕ ΕΝΑ ΣΩΛΗΝΑ 50mm ΣΤΑ ΚΟΥΤΙΑ ΔΑΠΕΔΟΥ ΓΙΑ ΚΑΛΩΔΙΩΣΗ ΕΙΚΟΝΑΣ ΗΧΟΥ. ΠΡΟΜΗΘΕΥΣΤΕ ΕΝΑ ΕΦΕΔΡΙΚΟ ΣΩΛΗΝΑ 25 mm.
9 PROVIDE FOUR (4) 100mm UNDERGROUND CONDUITS DEDICATED TO COMMUNICATION CABLING TO THE BUILDING ENTRANCE FACILITY FROM A MANHOLE. SEE ELECTRICAL SITE DRAWING ES100.
ΠΡΟΜΗΘΕΥΣΤΕ ΤΕΣΣΕΡΙΣ (4) ΥΠΟΓΕΙΟΠΟΙΗΜΕΝΟΥΣ ΣΩΛΗΝΕΣ ΤΩΝ 100 mm ΑΠΟΚΛΕΙΣΤΙΚΑ ΓΙΑ
ΚΑΛΩΔΙΩΣΗ ΕΠΙΚΟΙΝΩΝΙΩΝ ΣΤΗΝ ΕΓΚΑΤΑΣΤΑΣΗ ΕΙΣΟΔΟΥ ΤΟΥ ΚΤΙΡΙΟΥ ΑΠΟ ΕΝΑ ΦΡΕΑΤΙΟ.
10 COMMUNICATION PATHWAY SUPPORTING METHODS WILL FOLLOW LOCAL CODES REQUIRED FOR
THE SEISMIC ZONE. BRACING TO BE FIELD LOCATED AND COORDINATED WITH OTHER TRADES
PRIOR TO INSTALLATION.
ΟΙ ΜΕΘΟΔΟΙ ΣΤΗΡΙΞΗΣ ΤΩΝ ΟΔΕΥΣΕΩΝ ΕΠΙΚΟΙΝΩΝΙΩΝ ΘΑ ΕΙΝΑΙ ΣΥΜΦΩΝΟΙ ΜΕ ΤΟΥΣ ΕΘΝΙΚΟΥΣ
ΚΑΝΟΝΙΣΜΟΥΣ ΠΟΥ ΑΠΑΙΤΟΥΝΤΑΙ ΓΙΑ ΤΗΝ ΣΕΙΣΜΙΚΗ ΖΩΝΗ. ΟΙ ΘΕΣΕΙΣ ΤΩΝ ΣΤΗΡΙΞΕΩΝ ΘΑ
ΥΠΟΔΕΙΧΘΟΥΝ ΚΑΙ ΣΥΝΤΟΝΙΣΤΟΥΝ ΣΤΟ ΠΕΔΙΟ ΜΑΖΙ ΜΕ ΑΛΛΕΣ ΕΙΔΙΚΟΤΗΤΕΣ ΠΡΙΝ ΑΠΟ ΤΗΝ
ΕΓΚΑΤΑΣΤΑΣΗ.
11 PROVIDE PULL STRINGS IN CONDUITS OVER 3-METERS IN LENGTH AT THE TIME OF CONDUIT
INSTALLATION.
ΠΡΟΜΗΘΕΥΣΤΕ ΟΔΗΓΟ ΕΛΞΗΣ ΚΑΛΩΔΙΩΝ ΣΕ ΣΩΛΗΝΕΣ ΜΗΚΟΥΣ ΜΕΓΑΛΥΤΕΡΟΥ ΑΠΟ 3 ΜΕΤΡΑ ΚΑΤΑ
ΤΗΝ ΔΙΑΡΚΕΙΑ ΕΓΚΑΤΑΣΤΑΣΗΣ ΤΩΝ ΣΩΛΗΝΩΝ.
12 LOCATE AND PROVIDE APPROVED FIRE STOPPING PASS THROUGH DEVICES FOR COMMUNICATION
CABLING THROUGH WALLS INTO ENCLOSED SPACES AND THOUGH FLOOR PENETRATIONS.
SLEEVES PROVIDED SIZED ACCORDING TO THE NUMBER OF CABLES PASSING THROUGH.
ΕΝΤΟΠΙΣΤΕ ΚΑΙ ΠΡΟΜΗΘΕΥΣΤΕ ΕΓΚΕΚΡΙΜΕΝΕΣ ΣΥΣΚΕΥΕΣ ΠΥΡΟΦΡΑΓΜΩΝ ΓΙΑ ΤΙΣ ΚΑΛΩΔΙΩΣΕΙΣ
ΕΠΙΚΟΙΝΩΝΙΩΝ ΔΙΑΜΕΣΟΥ ΤΟΙΧΩΝ ΜΕΣΑ ΣΕ ΚΛΕΙΣΤΟΥΣ ΧΩΡΟΥΣ ΚΑΙ ΔΙΑΤΡΗΣΕΙΣ ΠΑΤΩΜΑΤΩΝ. ΟΙ
ΜΑΝΔΥΕΣ ΠΟΥ ΠΑΡΕΧΟΝΤΑΙ ΝΑ ΕΧΟΥΝ ΔΙΑΣΤΑΣΙΟΛΟΓΗΘΕΙ ΣΥΜΦΩΝΑ ΜΕ ΤΟΝ ΑΡΙΘΜΟ ΤΩΝ
ΚΑΛΩΔΙΩΝ ΠΟΥ ΠΕΡΝΑΝΕ.
13 PROVIDE CONDUIT FOR EACH TELECOMMUNICATION OUTLET TO NEAREST COMMUNICATION
HORIZONTAL CABLE TRAY OR WIREWAY IN THE DIRECTION OF THE COMMUNICATION ROOM THAT
THE OUTLET IS FED FROM.
ΠΡΟΜΗΘΕΥΣΤΕ ΣΩΛΗΝΑ ΣΕ ΚΑΘΕ ΛΗΨΗ ΤΗΛΕΠΙΚΟΙΝΩΝΙΩΝ ΠΡΟΣ ΤΗΝ ΚΟΝΤΙΝΟΤΕΡΗ ΣΧΑΡΑ
ΟΡΙΖΟΝΤΙΑΣ ΔΙΑΝΟΜΗΣ ΤΗΛΕΠΙΚΟΙΝΩΝΙΩΝ Ή ΟΔΕΥΣΗ ΚΑΛΩΔΙΩΝ ΠΡΟΣ ΤΗΝ ΚΑΤΕΥΘΥΝΣΗ ΤΟΥ
ΔΩΜΑΤΙΟΥ ΤΗΛΕΠΙΚΟΙΝΩΝΙΩΝ ΑΠΟ ΤΟ ΟΠΟΙΟ ΕΧΕΙ ΠΑΡΟΧΗ Η ΛΗΨΗ.
14 PROVIDE 130-MILLIMETER RADIUS CABLE DROPOUTS (WATERFALLS) FOR CABLING TRAVERSING
DOWN FROM THE WIRE BASKET TRAY OR CABLE LADDER RACK MANAGEMENT TRAY.
ΠΡΟΜΗΘΕΥΣΤΕ ΕΞΑΡΤΗΜΑ ΑΝΑΧΩΡΗΣΗΣ ΚΑΛΩΔΙΩΝ (ΚΑΤΑΡΡΑΚΤΗΣ) ΑΚΤΙΝΑΣ 130 ΧΙΛΙΟΣΤΩΝ ΓΙΑ
ΚΑΘΕ ΟΔΕΥΣΗ ΚΑΛΩΔΙΩΝ ΠΡΟΣ ΤΑ ΚΑΤΩ ΑΠΟ ΣΧΑΡΕΣ ΣΥΡΜΑΤΙΝΟΥ ΠΛΕΓΜΑΤΟΣ Ή ΣΚΑΛΙΕΡΑ
ΔΙΑΧΕΙΡΙΣΗΣ ΚΑΛΩΔΙΩΝ .
15 CABLE LADDER RUNWAY SUPPORT ACCESSORIES AND HARDWARE ACCEPTABLE AS COMPLETE
KITS FROM RUNWAY MANUFACTURER.
ΤΑ ΥΠΟΣΤΗΡΙΚΤΙΚΑ ΕΞΑΡΤΗΜΑΤΑ ΚΑΙ ΤΑ ΥΛΙΚΑ ΓΙΑ ΤΙΣ ΟΔΕΥΣΕΙΣ ΚΑΛΩΔΙΩΝ ΤΥΠΟΥ ΣΚΑΛΙΕΡΑΣ ΝΑ
ΕΙΝΑΙ ΑΠΟΔΕΚΤΑ ΣΑΝ ΟΛΟΚΛΗΡΩΜΕΝΟΣ ΕΞΟΠΛΙΣΜΟΣ ΑΠΟ ΤΟΝ ΚΑΤΑΣΚΕΥΑΣΤΗ ΤΩΝ ΟΔΕΥΣΕΩΝ
ΚΑΛΩΔΙΩΝ.
TELECOMMUNICATIONS PREMISE CABLING NOTES
ΠΑΡΑΤΗΡΗΣΕΙΣ ΕΓΚΑΤΑΣΤΑΣΗΣ ΚΑΛΩΔΙΩΣΗΣ ΤΗΛ/ΝΙΩΝ
1 ALL PREMISE CABLING TO INCLUDE INTRABUILDING BACKBONE CABLING MUST CONFORM AND BE INSTALLED TO THE SPECIFICATIONS DEFINED BY 27 10 00 AND THE MANUFACTURER INSTALLATION GUIDELINES TO
INCLUDE, BUT NOT LIMITED TO:
* TERMINATION POSITION/JACKET REMOVAL
* BEND RADIUS FOR UTP AND OPTICAL FIBER
* MANUFACTURER RECOMMENDED CABLE PULLING TENSION.
ΟΛΗ Η ΕΓΚΑΤΑΣΤΑΣΗ ΚΑΛΩΔΙΩΣΗΣ ΚΤΙΡΙΟΥ ΠΟΥ ΠΕΡΙΛΑΜΒΑΝΕΙ ΚΑΙ ΤΟ ΕΣΩΤΕΡΙΚΟ ΔΙΚΤΥΟ ΚΟΡΜΟΥ ΠΡΕΠΕΙ ΝΑ ΣΥΜΜΟΡΦΩΝΕΤΑΙ ΚΑΙ ΝΑ ΕΓΚΑΤΑΣΤΑΘΕΙ ΣΥΜΦΩΝΑ ΜΕ ΤΙΣ ΠΡΟΔΙΑΓΡΑΦΕΣ ΠΟΥ ΟΡΙΖΟΝΤΑΙ ΑΠΟ ΤΟ 27 10 00 ΚΑΙ ΤΙΣ ΟΔΗΓΙΕΣ ΕΓΚΑΤΑΣΤΑΣΗΣ ΤΟΥ ΚΑΤΑΣΚΕΥΑΣΤΗ ΠΟΥ ΠΕΡΙΛΑΜΒΑΝΟΥΝ, ΑΛΛΑ ΔΕΝ ΠΕΡΙΟΡΙΖΟΝΤΑΙ ΣΕ:
* ΤΕΡΜΑΤΙΚΕΣ ΘΕΣΕΙΣ / ΑΜΟΜΑΚΡΥΝΣΗ ΕΠΕΝΔΥΣΗΣ
* ΑΚΤΙΝΕΣ ΚΑΜΠΥΛΟΤΗΤΑΣ ΓΙΑ UTP ΚΑΙ ΟΠΤΙΚΕΣ ΙΝΕΣ
* ΣΥΝΙΣΤΩΜΕΝΕΣ ΑΠΟ ΤΟΝ ΚΑΤΑΣΚΕΥΑΣΤΗ ΤΑΣΗΣ ΕΛΞΗΣ ΚΑΛΩΔΙΩΝ
2 NIPRNet HORIZONTAL CABLING WHICH IS DISTRIBUTED FROM EACH TELECOMMUNICATIONS ROOM (TR) WILL BE GREEN CAT6 CABLING AND TERMINATED USING T568A PIN ASSIGNMENTS. NIPRNet WORK AREA OUTLETS TO BE CONSIST OF TWO (2) CAT6 UTP CABLES AND TERMINATED ON A GREEN 8P8C JACK. PROVIDE A 4-PORT
FACEPLATE WITH LABEL WINDOWS. USE MATCHING BLANKS TO FILL THE EMPTY POSITIONS.
H ΟΡΙΖΟΝΤΙΑ ΚΑΛΩΔΙΩΣΗ ΤΟΥ NIPRNET ΠΟΥ ΔΙΑΝΕΜΕΤΑΙ ΑΠΟ ΚΑΘΕ ΤΗΛΕΠΙΚΟΙΝΩΝΙΑΚΟ ΧΩΡΟ (ΤR) ΘΑ ΕΙΝΑΙ ΠΡΑΣΙΝΟΥ ΧΡΩΜΑΤΟΣ CAT6 ΚΑΙ ΤΕΡΜΑΤΙΖΕΤΑΙ ΧΡΗΣΙΜΟΠΟΙΩΝΤΑΣ ΤΙΣ ΘΕΣΕΙΣ ΑΚΡΟΔΕΚΤΩΝ ΣΥΜΦΩΝΑ ΜΕ ΤΟ T568A . ΟΙ ΤΕΡΜΑΤΙΚΕΣ ΛΗΨΕΙΣ ΤΟΥ NIPRNET ΣΤΙΣ ΘΕΣΕΙΣ ΕΡΓΑΣΙΑΣ ΘΑ ΑΠΟΤΕΛΟΥΝΤΑΙ ΑΠΟ ΔΥΟ (2) CAT6 UTP ΚΑΛΩΔΙΑ ΚΑΙ ΘΑ ΤΕΡΜΑΤΙΖΟΝΤΑΙ ΣΕ ΜΙΑ ΠΡΑΣΙΝΗ 8P8C ΘΥΡΑ. ΠΡΟΜΗΘΕΥΣΤΕ ΕΝΑ ΠΛΑΙΣΙΟ 4 ΘΥΡΩΝ ΜΕ ΘΕΣΗ
ΓΙΑ ΕΤΙΚΕΤΑ. ΧΡΗΣΙΜΟΠΟΙΗΣΤΕ ΛΕΥΚΑ ΚΑΛΥΜΜΑΤΑ ΓΙΑ ΤΙΣ ΑΔΕΙΕΣ ΘΕΣΕΙΣ.
3 SIPRNet HORIZONTAL CABLING WHICH IS DISTRIBUTED WITHIN THE CONFINES OF THE SIPRNet SECURE SPACE WILL BE A MINIMUM OF A TWO (2) 2-STRAND RED MM OPTICAL FIBER CABLE AND BE TERMINATED WITH AN LC
CONNECTOR.
Η ΟΡΙΖΟΝΤΙΑ ΚΑΛΩΔΙΩΣΗ ΤΟΥ SIPRNET ΠΟΥ ΔΙΑΝΕΜΕΤΑΙ ΕΝΤΟΣ ΤΩΝ ΟΡΙΩΝ ΤΟΥ ΑΣΦΑΛΗ ΧΩΡΟΥ ΤΟΥ SIPRNET ΘΑ ΕΙΝΑΙ ΤΟΥΛΑΧΙΣΤΟΝ ΕΝΑ ΚΟΚΚΙΝΟ ΚΑΛΩΔΙΟ ΜΜ ΟΠΤΙΚΗΣ ΙΝΑΣ 2 ΙΝΩΝ ΚΑΙ ΘΑ ΤΕΡΜΑΤΙΖΕΤΑΙ ΣΕ ΕΝΑ
ΣΥΝΔΕΣΜΟ ΤΥΠΟΥ LC.
4 SIPRNet WORK AREA OUTLETS CONSIST OF A DUPLEX LC BULKHEAD. PROVIDE A 4-PORT FACEPLATE WITH
LABEL WINDOWS. USE MATCHING BLANKS TO FILL THE EMPTY POSITIONS.
ΟΙ ΤΕΡΜΑΤΙΚΕΣ ΠΡΙΖΕΣ ΣΤΟΝ ΧΩΡΟ ΕΡΓΑΣΙΑΣ ΤΟΥ SIPRNET ΑΠΟΤΕΛΟΥΝΤΑΙ ΑΠΟ ΕΝΑ ΔΙΠΛΟ ΣΥΝΔΕΣΜΟ ΤΥΠΟΥ LC.ΠΡΟΜΗΘΕΥΣΤΕ ΕΝΑ ΠΛΑΙΣΙΟ 4 ΘΥΡΩΝ ΜΕ ΘΕΣΗ ΓΙΑ ΕΤΙΚΕΤΑ. ΧΡΗΣΙΜΟΠΟΙΗΣΤΕ ΛΕΥΚΑ ΚΑΛΥΜΜΑΤΑ ΓΙΑ ΤΙΣ
ΑΔΕΙΕΣ ΘΕΣΕΙΣ.
5 TV OUTLETS CONSIST OF TWO (2) GREEN CAT6 CABLES AND ONE (1) RG-6 CABLE. MOUNT USING A 4-PORT
FACEPLATE WITH LABEL WINDOWS. USE MATCHING BLANKS TO FILL THE EMPTY POSITIONS.
ΟΙ ΤΕΡΜΑΤΙΚΕΣ ΠΡΙΖΕΣ ΤΗΛΕΟΡΑΣΗΣ (TV) ΑΠΟΤΕΛΟΥΝΤΑΙ ΑΠΟ ΔΥΟ (2) ΠΡΑΣΙΝΑ ΚΑΛΩΔΙΑ ΚΑΤΗΓΟΡΙΑΣ CAT6 ΚΑΙ ΕΝΑ (1) ΚΑΛΩΔΙΟ ΤΥΠΟΥ RG-6. ΕΓΚΑΤΑΣΤΗΣΤΕ ΜΙΑ ΜΟΝΑΔΑ 4 ΕΙΣΟΔΩΝ ΜΕ ΠΛΑΙΣΙΑ ΕΠΙΣΗΜΑΝΣΗΣ.
ΧΡΗΣΙΜΟΠΟΙΗΣΤΕ ΛΕΥΚΑ ΚΑΛΥΜΜΑΤΑ ΓΙΑ ΤΙΣ ΑΔΕΙΕΣ ΘΕΣΕΙΣ.
6 NIPRNET AUDIO VISUAL OUTLETS TO CONSIST OF TWO (2) GREEN CAT6 CABLES, ONE (1) HDMI CABLE, ONE (1) VGA OR DVI CABLE. SIPRNET AUDIO VISUAL OUTLETS WILL CONSIST OF TWO (2) TWO-STRAND RED MM OPTICAL FIBER CABLE, ONE (1) HDMI, ONE (1) AUDIO INPUT CABLE, AND ONE (1) VGA OR DVI CABLE. MOUNT
USING AN AUDIO-VISUAL FACEPLATE TO HOUSE ALL CONNECTIONS.
ΟΙ ΕΞΟΔΟΙ ΗΧΟΥ ΕΙΚΟΝΑΣ ΓΙΑ ΤΟ NIPRNET ΑΠΟΤΕΛΟΥΝΤΑΙ ΑΠΟ ΔΥΟ (2) ΠΡΑΣΙΝΑ ΚΑΛΩΔΙΑ ΚΑΤΗΓΟΡΙΑΣ 6, ΕΝΑ
(1) ΚΑΛΩΔΙΟ HDMI, ENA (1) ΚΑΛΩΔΙΟ VGA Ή DVI. ΟΙ ΕΞΟΔΟΙ ΗΧΟΥ ΕΙΚΟΝΑΣ ΓΙΑ ΤΟ SIPRNET ΘΑ ΑΠΟΤΕΛΟΥΝΤΑΙ ΑΠΟ ΔΥΟ (2) ΚΟΚΚΙΝΑ ΚΑΛΩΔΙΑ MM ΟΠΤΙΚΗΣ ΙΝΑΣ ΔΥΟ ΙΝΩΝ, ΕΝΑ (1) ΚΑΛΩΔΙΟ HDMI, ΕΝΑ (1) ΚΑΛΩΔΙΟ ΗΧΟΥ, ΚΑΙ ENA (1) ΚΑΛΩΔΙΟ VGA Ή DVI. ΕΓΚΑΤΑΣΤΗΣΤΕ ΧΡΗΣΙΜΟΠΟΙΩΝΤΑΣ ΕΝΑ ΠΛΑΙΣΙΟ ΗΧΟΥ ΕΙΚΟΝΑΣ ΠΟΥ ΘΑ
ΦΙΛΟΞΕΝΕΙ ΟΛΕΣ ΤΙΣ ΠΑΡΑΠΑΝΩ ΣΥΝΔΕΣΕΙΣ.
7 LABEL CABLES PER TIA/EIA-606-A, "ADMINSRTATION STANDARD FOR COMMERCIAL TELECOMMUNICATIONS
INFRASTRUCTURER.
ΤΑ ΚΑΛΩΔΙΑ ΘΑ ΕΙΝΑΙ ΕΠΙΣΗΜΑΣΜΕΝΑ ΣΥΜΦΩΝΑ ΜΕ ΤΗΝ TIA/EIA-606-A,”ΔΙΟΙΚΗΤΙΚΟ ΠΡΟΤΥΠΟ ΓΙΑ ΤΗΝ
ΕΜΠΟΡΙΚΗ ΤΗΛΕΠΙΚΟΙΝΩΝΙΑΚΗ ΥΠΟΔΟΜΗ’’.
8 WIRELESS ACCESS POINTS TO CONSIST OF TWO (2) BLUE CAT6 CABLES TO EACH AP LOCATION. LEAVE 3-METERS OF SLACK IN THE CEILING. TERMINATE ON AN 8P8C JACK AND PLACE IN A RATED 2-PORT SURFACE
MOUNT BOX.
ΤΑ ΑΣΥΡΜΑΤΑ ΣΗΜΕΙΑ ΠΡΟΣΒΑΣΗΣ ΘΑ ΑΠΟΤΕΛΟΥΝΤΑΙ ΑΠΟ ΔΥΟ (2) ΜΠΛΕ ΚΑΤΗΓΟΡΙΑΣ 6 ΚΑΛΩΔΙΑ ΣΕ ΚΑΘΕ ΘΕΣΗ ΑΣΥΡΜΑΤΗΣ ΠΡΟΣΒΑΣΗΣ (AP). ΑΦΗΣΤΕ 3 ΜΕΤΡΑ ΕΠΙΠΛΕΟΝ ΚΑΛΩΔΙΟ ΣΤΗΝ ΨΕΥΔΟΡΟΦΗ. ΤΕΡΜΑΤΙΣΤΕ ΠΑΝΩ ΣΕ ΜΙΑ 8P8C ΘΥΡΑ ΚΑΙ ΤΟΠΟΘΕΤΗΣΤΕ ΣΕ ΕΝΑ ΚΑΤΑΛΛΗΛΟ 2 ΘΥΡΩΝ ΚΥΤΙΟ ΕΠΙΦΑΝΕΙΑΚΗΣ
ΤΟΠΟΘΕΤΗΣΗΣ.
9 USE WET LOCATION APPROVED CABLE FOR ANY COMMUNICATION CABLE IN CONDUIT THAT IS IN SLAB-ON GRADE OR IN SLAB. USE ALSO IN ANY CONDUIT THAT IS EXPOSED TO THE ELEMENTS. DO NOT EXCEED 15 METERS OF EXPOSED WET LOCATION CABLE WITHIN THE BUILDING. FOR INSTALLATIONS TO FLOOR BOXES.
ΧΡΗΣΙΜΟΠΟΙΕΙΣΤΕ ΕΓΚΕΚΤΡΙΜΕΝΟ ΚΑΛΩΔΙΟ ΓΙΑ ΧΡΗΣΗ ΣΕ ΥΓΡΕΣ ΠΕΡΙΟΧΕΣ ΓΙΑ ΟΛΑ ΤΑ ΚΑΛΩΔΙΑ ΤΗΛΕΠΙΚΟΙΝΩΝΙΩΝ ΕΝΤΟΣ ΣΩΛΗΝΑ ΠΟΥ ΒΡΙΣΚΟΝΤΑΙ ΣΕ ΠΛΑΚΑ ΣΤΟ ΕΔΑΦΟΣ Ή ΣΕ ΠΛΑΚΑ. ΧΡΗΣΙΜΟΠΟΙΕΙΣΤΕ ΤΟ ΕΠΙΣΗΣ ΚΑΙ ΣΕ ΚΑΘΕ ΣΩΛΗΝΑ ΠΟΥ ΕΙΝΑΙ ΕΚΤΕΘΕΙΜΕΝΟΣ ΣΕ ΣΤΟΙΧΕΙΑ ΤΗΣ ΦΥΣΗΣ. ΝΑ ΜΗΝ ΥΠΕΡΒΟΥΝ ΤΑ 15 ΜΕΤΡΑ ΕΚΤΕΘΕΙΜΕΝΟΥ ΚΑΛΩΔΙΟΥ ΓΙΑ ΧΡΗΣΗ ΣΕ ΥΓΡΗ ΕΠΙΦΑΝΕΙΑ ΕΝΤΟΣ ΤΟΥ ΚΤΙΡΙΟΥ, ΓΙΑ ΕΓΚΑΤΑΣΤΑΣΗ
ΣΕ ΚΟΥΤΙΑ ΔΑΠΕΔΟΥ.
APPROVED BY: PAM COWDEN, P.E.
FEAD BRANCH HEAD
VIA SAT-TO-FORM
DESCRIPTION
ΠΕΡΙΓΡΑΦΗ
SYMBOLS
ΣΥΜΒΟΛΑ
TELECOMMUNICATIONS SYMBOLS
ΣΥΜΒΟΛΑ ΕΠΙΚΟΙΝΩΝΙΩΝ
CATV OUTLET- (2) GREEN CAT6, (1) RG-6 IN 25mm CONDUIT. SEE T-501, DETAIL
A1. COORDINATE WITH CATV INSTALLER.
CATV ΠΡΙΖΑ- (2) ΠΡΑΣΙΝΑ CAT6, (1) RG-6 ΕΝΤΟΣ 25mm ΣΩΛΗΝΑ. ΒΛΕΠΕ
ΛΕΠΤΟΜΕΡΕΙΑ Α1 ΣΧΕΔΙΟ Τ-501. ΣΥΝΤΟΝΙΣΤΕ ΜΕ ΤΟΝ ΕΓΚΑΤΑΣΤΑΤΗ ΤΟΥ
ΣΥΣΤΗΜΑΤΟΣ CATV.
WIRELESS ACCESS POINT OUTLET, MOUNTED IN CEILING,
(2) GREEN CAT6 CABLES
ΠΡΙΖΑ ΣΗΜΕΙΟΥ ΑΣΥΡΜΑΤΗΣ ΠΡΟΣΒΑΣΗΣ, ΤΟΠΟΘΕΤΗΜΕΝΗ ΣΤΗΝ ΟΡΟΦΗ, ΔΥΟ
(2) ΠΡΑΣΙΝΑ CAT6 ΚΑΛΩΔΙΑ
TELECOMMUNICATIONS EQUIPMENT CABINET LOCKABLE, 1829mm HIGH x 736mm WIDE x 711mm DEEP.
SEISMIC RATED CABINET TESTED IN ACCORDANCE WITH NEBS GR-63 CORE
AND ANSI T1.329.
ΕΡΜΑΡΙΟ ΕΞΟΠΛΙΣΜΟΥ ΤΗΛΕΠΙΚΟΙΝΩΝΙΩΝ ΠΟΥ ΚΛΕΙΔΩΝΕΙ, 1829mm ΥΨΟΣ x 736mm ΠΛΑΤΟΣ x 711mm ΒΑΘΟΣ
ΕΡΜΑΡΙΟ ΚΑΤΑΛΛΗΛΟ ΓΙΑ ΕΓΚΑΤΑΣΤΑΣΗ ΣΕ ΧΩΡΟΥΣ ΜΕ ΕΝΤΟΝΕΣ ΔΟΝΗΣΕΙΣ
(SEISMIC RATED) ΕΛΕΓΜΕΝΟ ΣΥΜΦΩΝΑ ΜΕ NEBS GR-63 KAI ANSI T1.329
TELECOMMUNICATIONS CABINET WALL MOUNTED,MOUNT AT 2000mm AFF 516mm x 381mm ΕΠΙΤΟΙΧΟ ΕΡΜΑΡΙΟ ΤΗΛΕΠΙΚΟΙΝΩΝΙΩΝ ΤΟΠΟΘΕΤΕΙΤΑΙ 2000mm AFF 516mm x 381mm
SECTION LOCATED ON SAME SHEET
ΤΟΜΗ ΠΟΥ ΒΡΙΣΚΕΤΑΙ ΣΤΟ ΙΔΙΟ ΣΧΕΔΙΟ
SECTION LOCATED ON DIFFERENT SHEET
ΤΟΜΗ ΠΟΥ ΒΡΙΣΚΕΤΑΙ ΣΕ ΔΙΑΦΟΡΕΤΙΚΟ
ΣΧΕΔΙΟ
X
XXX-XXXX
KEYED NOTE
ΣΗΜΕΙΩΣΗ ΣΧΕΔΙΟΥ
BOX DENOTES FLOOR MOUNTED DEVICE
ΤΟ ΤΕΤΡΑΓΩΝΟ ΠΛΑΙΣΙΟ ΔΗΛΩΝΕΙ ΣΥΣΚΕΥΗ ΤΟΠΟΘΕΤΗΜΕΝΗ ΣΤΟ ΔΑΠΕΔΟ
TV
AP
WALL TELEPHONE OUTLET- (1) GREEN CAT6 IN 20mm CONDUIT
ΕΠΙΤΟΙΧΗ ΠΡΙΖΑ ΤΗΛΕΦΩΝΟΥ (1) ΠΡΑΣΙΝΟ CAT6 ΣΕ 20ΜΜ ΣΩΛΗΝΑ
W
C
NIPRNET OUTLET- NIPRNET (2) GREEN CAT6 IN 25mm CONDUIT. SEE T-501, DETAIL A2.
NIPRNET ΠΡΙΖΑ - NIPERNET (2) ΠΡΑΣΙΝΑ CAT6 ΣΕ 25mm ΣΩΛΗΝΑ ΚΑΛΩΔΙΩΝ.
ΒΛΕΠΕ ΛΕΠΤΟΜΕΡΕΙΑ Α2 ΣΧΕΔΙΟ Τ-501.
SIPRNET OUTLET- RED (2) 2-STRAND DUPLEX MM FOC IN 25mm CONDUIT. SEE
T-501, DETAIL A4.
(2) ΚΟΚΚΙΝΕΣ-ΠΡΙΖΕΣ SIPERNET 2-ΔΙΠΛΕΣ ΟΠΤΙΚΕΣ ΙΝΕΣ MM FOC ΣΕ ΣΩΛΗΝΑ 25
mm. ΒΛΕΠΕ Τ-501, ΛΕΠΤΟΜΕΡΙΑ Α4.
NIPRNET AV OUTLET- NIPRNET (1) HDMI, (1) AUDIO, (1) VGA, GREEN (2) CAT6 IN
50mm CONDUIT. SEE T-501, DETAIL B2.
NIPRNET AV ΠΡΙΖΑ - NIPERNET (1) HDMI, (1) ΗΧΟΣ, (1) VGA, ΠΡΑΣΙΝΟ (2) CAT6
ΣΕ 50mm ΣΩΛΗΝΑ ΚΑΛΩΔΙΩΝ. ΒΛΕΠΕ ΛΕΠΤΟΜΕΡΕΙΑ B2 ΣΧΕΔΙΟ Τ-501
AV
NIPRNET OUTLET SYSTEMS FURNITURE - CUBICLE FEED NIPRNET (2) GREEN
CAT6 IN 25mm CONDUIT. COORDINATE WITH SYSTEMS FURNITURE INSTALLER.
NIPERNET ΠΡΙΖΑ ΣΥΣΤΗΜΑΤΟΣ ΕΠΙΠΛΩΝ - ΤΡΟΦΟΔΟΣΙΑ ΓΡΑΦΕΙΩΝ ΑΝΟΙΚΤΟΥ
ΧΩΡΟΥ (CUBICLE) NIPERNET (2) ΠΡΑΣΙΝΑ ΚΑΛΩΔΙΑ CAT6 ΣΕ ΣΩΛΗΝΑ 25mm.
ΣΥΝΤΟΝΙΣΤΕ ΜΕ ΤΟΝ ΕΓΚΑΤΑΣΤΑΤΗ ΣΥΣΤΗΜΑΤΟΣ ΕΠΙΠΛΩΝ
EM NIPRNET OUTLET- ELECTRICAL METER MONITORING CONNECTION (1) GREEN
CAT6 CABLE IN 25mm CONDUIT FROM BASKET TRAY. INSTALLED TO METER VIA
CONDUIT FROM BASKET TRAY.SEE T-501, DETAIL C1.
COORDINATE WITH ELECTRICAL FOR MOUNTING HEIGHT
NIPERNET ΠΡΙΖΑ - ΣΥΝΔΕΣΗ ΜΕΤΡΗΤΗ ΚΑΤΑΝΑΛΩΣΗΣ ΡΕΥΜΑΤΟΣ (1) ΠΡΑΣΙΝΟ
CAT6 ΚΑΛΩΔΙΟ ΣΕ ΣΩΛΗΝΑ 25mm ΑΠΟ ΤΗΝ ΣΧΑΡΑ ΣΥΡΜΑΤΙΝΟΥ ΠΛΕΓΜΑΤΟΣ.
ΕΓΚΑΤΕΣΤΗΜΕΝΗ ΣΤΟΝ ΜΕΤΡΗΤΗ ΜΕΣΩ ΕΝΟΣ ΣΩΛΗΝΑ ΑΠΟ ΤΗΝ ΣΧΑΡΑ
ΣΥΡΜΑΤΙΝΟΥ ΠΛΕΓΜΑΤΟΣ. ΒΛΕΠΕ ΛΕΠΤΟΜΕΡΕΙΑ C1 ΣΧΕΔΙΟ Τ-501. ΣΥΝΤΟΝΙΣΤΕ
ΜΕ ΤΑ ΗΛΕΚΤΡΟΛΟΓΙΚΑ ΓΙΑ ΥΨΟΣ ΤΟΠΟΘΕΤΗΣΗΣ
CEILING MOUNTED PAGING SPEAKER
ΗΧΕΙΟ ΕΙΔΟΠΟΙΗΣΗΣ ΤΟΠΟΘΕΤΗΜΕΝΟ ΣΤΗΝ ΟΡΟΦΗS
AV SIPRNET AV OUTLET- SIPRNET (1) HDMI, (1) AUDIO, (1) VGA, (1) RED 2-STRAND
MM FOC IN 50mm CONDUIT. SEE T-501, DETAIL C2.
SIPRNET AV ΠΡΙΖΑ - SIPRNET (1) HDMI, (1) AUDIO, (1) VGA, (1) KOKKINΑ 2 ΙΝΩΝ
MM FOC ΣΕ 50mm ΣΩΛΗΝΑ ΚΑΛΩΔΙΩΝ. ΒΛΕΠΕ ΛΕΠΤΟΜΕΡΕΙΑ C2 ΣΧΕΔΙΟ Τ-501.
WALL MOUNTED PAGING HORN
ΕΠΙΤΟΙΧΗ ΚΟΡΝΑ ΕΙΔΟΠΟΙΗΣΗΣ
SP
FIRE ALARM OUTLET- (2) GREEN CAT6 IN 25mm CONDUIT. SEE T-501, DETAIL
A2. COORDINATE WITH FACP INSTALLER.
ΠΡΙΖΑ ΣΥΝΑΓΕΡΜΟΥ ΠΥΡΚΑΓΙΑΣ- (2) ΠΡΑΣΙΝΑ CAT6 ΣΕ 25mm ΣΩΛΗΝΑ
ΚΑΛΩΔΙΩΝ. ΒΛΕΠΕ ΛΕΠΤΟΜΕΡΕΙΑ Α2 ΣΧΕΔΙΟ Τ-501. ΣΥΝΤΟΝΙΣΤΕ ΜΕ ΤΟΝ
ΕΓΚΑΤΑΣΤΑΤΗ ΤΟΥ FACP
FA
CABLE TRAY, TYPE AND DIMENSIONS AS INDICATED ON DRAWING CABLE TRAY
TAGS
ΣΧΑΡΑ ΚΑΛΩΔΙΩΝ, ΤΥΠΟΣ ΚΑΙ ΔΙΑΣΤΑΣΕΙΣ ΟΠΩΣ ΥΠΟΔΕΙΚΝΥΕΤΑΙ ΣΤΑ
ΤΑΜΠΕΛΑΚΙΑ ΑΝΑΓΝΩΡΙΣΗΣ ΣΧΑΡΩΝ ΚΑΛΩΔΙΩΝ ΣΤΑ ΣΧΕΔΙΑ
mm x mm
H = XXXmmCT
CABLE TRAY SIZE
ΜΕΓΕΘΟΣ ΣΧΑΡΑΣ ΚΑΛΩΔΙΩΝ
CABLE TRAY HEIGHT
ΥΨΟΣ ΣΧΑΡΑΣ ΚΑΛΩΔΙΩΝ
CT = CABLE TRAY
CT = ΣΧΑΡΑ ΚΑΛΩΔΙΩΝ
CABLE TRAY IDENTIFICATION TAG
ΤΑΜΠΕΛΑΚΙ ΑΝΑΓΝΩΡΙΣΗΣ ΣΧΑΡΑΣ ΚΑΛΩΔΙΩΝ
AV AV CEILING MOUNTED SPEAKERS, 2 x 2.5 mm2 CABLE ΑV HXEIA ΤΟΠΟΘΕΤΟΥΝΤΑΙ ΣΤΗΝ ΟΡΟΦΗ, ΚΑΛΩΔΙΟ 2 x 2.5 mm2
J
JUNCTION BOX
ΚΟΥΤΙ ΔΙΑΣΥΝΔΕΣΗΣ
DEVICES/EQUIPMENT
ΣΥΣΚΕΥΕΣ/ΕΞΟΠΛΙΣΜΟΣ
MOUNTING HEIGHT (AFF)
ΥΨΟΣ ΤΟΠΟΘΕΤΗΣΗΣ (AFF)
MEASURED TO:
ΜΕΤΡΗΣΗ ΑΠΟ:
TELECOMMUNICATIONS OUTLETS
ΤΕΡΜΑΤΙΚΕΣ ΠΡΙΖΕΣ ΤΗΛΕΠΙΚΟΙΝΩΝΙΩΝ
460 mm BOTTOM
ΚΑΤΩ ΜΕΡΟΣ
TELECOMMUNICATIONS OUTLETS - OVER COUNTER
ΤΕΡΜΑΤΙΚΕΣ ΠΡΙΖΕΣ ΤΗΛ/ΝΙΩΝ -ΠΑΝΩ ΑΠΟ ΠΑΓΚΟΥΣ
150 mm
BOTTOM (OVER TOP OF COUNTER)
ΚΑΤΩ ΜΕΡΟΣ ( ΠΑΝΩ ΑΠΟ ΤΟ ΠΑΝΩ
ΜΕΡΟΣ ΤΟΥ ΠΑΓΚΟΥ)
MOUNTING HEIGHT SCHEDULE
ΠΙΝΑΚΑΣ ΥΨΩΝ ΤΟΠΟΘΕΤΗΣΗΣ
MOUNTING HEIGHT SCHEDULE NOTES:
ΣΗΜΕΙΩΣΕΙΣ ΤΟΥ ΠΙΝΑΚΑ ΥΨΟΥΣ ΤΟΠΟΘΕΤΗΣΗΣ
1. USE ABOVE INDICATED MOUNTING HEIGHTS UNLESS INDICATED OTHER WISE ON DRAWINGS OR SPECIFICATIONS.
ΧΡΗΣΙΜΟΠΟΙΗΣΤΕ ΤΑ ΥΨΗ ΤΟΠΟΘΕΤΗΣΗΣ ΠΟΥ ΔΕΙΧΝΟΝΤΑΙ ΠΑΡΑΠΑΝΩ ΕΚΤΟΣ ΕΑΝ ΔΕΙΧΝΕΤΑΙ ΔΙΑΦΟΡΕΤΙΚΑ ΣΤΑ
ΣΧΕΔΙΑ Η' ΣΤΙΣ ΠΡΟΔΙΑΓΡΑΦΕΣ
2. COORDINATE TV MOUNTING HEIGHTS WITH FIELD CONDITIONS, OTHER TRADES, AND RELATED EQUIPMENT.
COORDINATE LOCATION ADJACENT TO ELECTRICAL RECEPTACLES PRIOR TO INSTALLATION.
ΣΥΝΤΟΝΙΣΤΕ ΤΑ ΥΨΗ ΤΟΠΟΘΕΤΗΣΗΣ TV ΜΕ ΤΙΣ ΤΟΠΙΚΕΣ ΣΥΝΘΗΚΕΣ, ΑΛΛΕΣ ΕΙΔΙΚΟΤΗΤΕΣ, ΚΑΙ ΣΧΕΤΙΚΟ ΕΞΟΠΛΙΣΜΟ
ΣΥΝΤΟΝΙΣΤΕ ΤΗΝ ΘΕΣΗ ΔΙΠΛΑ ΣΤΙΣ ΗΛΕΚΤΡΙΚΕΣ ΛΗΨΕΙΣ ΠΡΙΝ ΤΗΝ ΕΓΚΑΤΑΣΤΑΣΗ
3. COORDINATE WALL TERMINATION ON INSERTS BASED ON SIZE OF TV OR AV DISPLAYS BEING INSTALLED (TYP).
ΣΥΝΤΟΝΙΣΤΕ ΤΟΥΣ ΕΠΙΤΟΙΧΟΥΣ ΤΕΡΜΑΤΙΣΜΟΥΣ ΣΕ ΕΣΟΧΕΣ ΒΑΣΙΖΟΜΕΝΟΙ ΣΤΟ ΜΕΓΕΘΟΣ ΤΩΝ TV Ή AV ΟΘΟΝΩΝ ΠΟΥ
ΘΑ ΤΟΠΟΘΕΤΗΘΟΥΝ (TYP) .
4. TYPICAL FURNITURE DATA OUTLETS MOUNTED UNDERNEATH SEATING AND CONFERENCE ROOM TABLES, OR INSIDE
CASEWORK.
ΤΥΠΙΚΕΣ ΛΗΨΕΙΣ ΔΕΔΟΜΕΝΩΝ ΕΠΙΠΛΩΝ ΤΟΠΟΘΕΤΟΥΝΤΑΙ ΚΑΤΩ ΑΠΟ ΚΑΘΙΣΜΑΤΑ ΚΑΙ ΤΡΑΠΕΖΙΑ ΣΥΣΚΕΨΕΩΝ, Ή ΕΝΤΟΣ
ΚΑΤΑΣΚΕΥΩΝ
5. PAGING SPEAKERS AND ACCESS POINTS TO BE MOUNTED ON CEILING UNLESS NOTED OTHERWISE. REFER TO
ARCHITECTURAL REFLECTED CEILING PLANS, DRAWINGS A-131 - A-142.
ΗΧΕΙΑ ΕΙΔΟΠΟΙΗΣΗΣ ΚΑΙ ΕΞΟΠΛΙΣΜΟΣ ΣΗΜΕΙΩΝ ΠΡΟΣΒΑΣΗΣ ΤΟΠΟΘΕΤΟΥΝΤΑΙ ΠΑΝΩ ΣΤΗΝ ΟΡΟΦΗ ΕΚΤΟΣ ΑΝ
ΑΝΑΦΕΡΕΤΑΙ ΔΙΑΦΟΡΕΤΙΚΑ. ΑΝΑΤΡΕΞΤΕ ΣΤΑ ΑΡΧΙΤΕΚΤΟΝΙΚΑ ΣΧΕΔΙΑ Α-131 - Α-132 ΚΑΤΟΠΤΡΙΚΑ ΣΧΕΔΙΑ ΨΕΥΔΟΡΟΦΗΣ
TELECOMMUNICATIONS OUTLETS W - TELEPHONE
ΤΕΡΜΑΤΙΚΕΣ ΠΡΙΖΕΣ ΤΗΛΕΠ/ΝΙΩΝ W - ΤΗΛΕΦΩΝΙΚΕΣ
1220 mm CENTER
ΚΕΝΤΡΟ
COLUMN MOUNTED PAGING HORN
ΚΟΡΝΕΣ ΕΙΔΟΠΟΙΗΣΗΣ ΤΟΠΟΘ/ΜΕΝΕΣ ΣΕ ΚΟΛΩΝΑ
3000 mm
TELECOMMUNICATIONS OUTLET - AV
ΤΕΡΜΑΤΙΚΕΣ ΠΡΙΖΕΣ ΤΗΛΕΠΙΚΟΙΝΩΝΙΩΝ - AV
460 mm BOTTOM
ΚΑΤΩ ΜΕΡΟΣ
BOTTOM
ΚΑΤΩ ΜΕΡΟΣ
SM
D
C
B
1 2 3 4 5
NOT TO SCALE
1568016
DWG
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.
SCALE:
N62470-23-C-XXXX
RICHARD L STEPHENS, P.E.
LMM/MWL
CHIEF ENG/ARCH
DES DRW CHK
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
S O
U D
A B
A
YA
DRAWFORM REVISION: 25 AUGUST 2020
1 2 3 4 5
D
C
B
A
UNCLASSIFIED
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
A T
L A
N T
IC
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
N O
R F
O L K
V
A L A
N T
C A
P
IT
A L I M
P R
O V
E M
E N
T S
BRANCH MANAGER
PM/DM
SATISFACTORY TO DATE
FIRE PROTECTION DPS (DOUG STULTZ)
SEK (SOLVEIGH KEENE)
/3
/2
:1 :5
A
M
C R e v it L o c a l_ M o d e ls \2
\P
-1
-T R d ia n e .r io s E
Z M
N
.r v t
03/31/2023
T-002
MA DR JH
P J
O
IN
T M
O B
IL
IT
Y P
R O
C E
S S
IN
G
F A
C
IL
IT
Y
S O
U D
A B
A Y
G
R E
E C
E
G E
N E
R A
L N
O T
E S
A N
D A
B B
R E
V
IA
T
IO
N S
S H
E E
T
O F
14068906
T -0
Γ Ε
Ν
ΙΚ
Ε Σ
Σ Η
Μ Ε
ΙΩ
Σ
Ε
ΙΣ
Κ Α
Ι Σ
Υ Ν
Τ Μ
Η Σ
Ε
ΙΣ
Σ Χ
Ε Δ
ΙΟ
Α
Π Ο
TELECOMMUNICATIONS ABBREVIATIONS
ΣΥΝΤΜΗΣΕΙΣ ΤΗΛΕΠΙΚΟΙΝΩΝΙΩΝ
SC ΤΥΠΟΣ ΣΥΝΔΕΣΗΣ ΟΠΤΙΚΗΣ ΙΝΑΣ
SCP SECURITY CONTROL PANEL
SCP ΠΙΝΑΚΑΣ ΕΛΕΓΧΟΥ ΑΣΦΑΛΕΙΑΣ
SIPRNET SECRET INTERNET PROTOCOL ROUTER
NETWORK
SIPRNET ΑΠΟΡΡΗΤΟ ΠΡΩΤΟΚΟΛΛΟ ΔΙΑΔΥΚΤΙΟΥ
ΔΡΟΜΟΛΟΓΗΣΗΣ ΔΙΚTΥΩΝ
SM SINGLEMODE
SM ΜΟΝΟΤΡΟΠΗ
ST STRAND
ST ΙΝΑ
T --------------------
TB TERMINAL BLOCK
TB ΤΕΡΜΑΤΙΚΗ ΔΙΑΤΑΞΗ
TGB TELECOM GROUNDING BUS BAR
TGB ΜΠΑΡΑ ΓΕΙΩΣΕΩΣ ΤΗΛΕΠΙΚΟΙΝΩΝΙΩΝ
TMGB TELECOM MAIN GROUNDING BUS BAR
TMGB ΚΥΡΙΑ ΜΠΑΡΑ ΓΕΙΩΣΕΩΣ ΤΗΛΕΠΙΚΟΙΝΩΝΙΩΝ
TR TELECOMMUNICATIONS ROOM
TR
TV TELEVISION
TV ΤΗΛΕΟΡΑΣΗ
TYP TYPICAL
TYP ΤΥΠΙΚΟ
U --------------------
UTP UNSHIELDED TWISTED PAIR
UTP ΑΘΩΡΑΚΙΣΤΟ ΚΑΛΩΔΙΟ ΣΥΝΕΣΤΡΑΜΜΕΝΟΥ
ΖΕΥΓΟΥΣ
W --------------------
W/O WITHOUT
W/O ΧΩΡΙΣ
WAO WORK AREA OUTLET
WAO ΠΡΙΖΑ ΠΕΡΙΟΧΗΣ ΕΡΓΑΣΙΑΣ
WAP WIRELESS ACCESS POINT
WAP ΣΗΜΕΙΟ ΑΣΥΡΜΑΤΗΣ ΠΡΟΣΒΑΣΗΣ
TELECOMMUNICATIONS ABBREVIATIONS
ΣΥΝΤΜΗΣΕΙΣ ΤΗΛΕΠΙΚΟΙΝΩΝΙΩΝ
A --------------------
AFF ABOVE FINISHED FLOOR
AFF ΠΑΝΩ ΑΠΟ ΤΕΛΕΙΩΜΕΝΟ ΠΑΤΩΜΑ
AV AUDIO VISUAL
AV ΟΠΤΙΚΟΑΚΟΥΣΤΙΚΟΣ
C --------------------
CAT6 CATEGORY 6 UTP CABLE
CAT6 ΚΑΛΩΔΙΟ UTP ΚΑΤΗΓΟΡΙΑΣ 6
CATV COMMUNITY ANTENNA TELEVISION
CATV ΕΠΙΓΕΙΑ ΚΕΡΑΙΑ ΤΗΛΕΟΡΑΣΗΣ
CT CABLE TRAY
CT ΣΧΑΡΑ ΚΑΛΩΔΙΩΝ
D --------------------
DTL DETAIL
DTL ΛΕΠΤΟΜΕΡΙΑ
DWG DRAWING
DWG ΣΧΕΔΙΟ
E --------------------
EA EACH
EA ΚΑΘΕ
EF ENTRANCE FACILITY
EF ΕΙΣΟΔΟΣ ΕΓΚΑΤΑΣΤΑΣΗΣ
EL, ELEV ELEVATION
EL,ELEV ΥΨΟΣ / ΟΨΗ / ΣΤΑΘΜΗ
EMI ELECTROMAGNETIC INTERFERNCE
EMI ΗΛΕΚΤΡΟΜΑΓΝΗΤΙΚΗ ΠΑΡΕΜΒΟΛΗ
ER EQUIPMENT ROOM
ER ΧΩΡΟΣ / ΔΩΜΑΤΙΟ ΕΞΟΠΛΙΣΜΟΥ
ESS ELECTRONIC SECURITY SYSTEM
ESS ΗΛΕΚΤΡΟΝΙΚΟ ΣΥΣΤΗΜΑ ΑΣΦΑΛΕΙΑΣ
F --------------------
F/R FRONT AND REAR
F/R ΕΜΠΡΟΣ ΚΑΙ ΠΙΣΩ
FA FIRE ALARM
FA ΣΥΝΑΓΕΡΜΟΣ ΠΥΡΚΑΓΙΑΣ
FDU FIBER OPTIC DISTRIBUTION UNIT
FDU ΜΟΝΑΔΑ ΔΙΑΝΟΜΗΣ ΟΠΤΙΚΗΣ ΙΝΑΣ
FO FIBER OPTIC
FO ΟΠΤΙΚΗ ΙΝΑ
FOC FIBER OPTIC CABLE
FOC ΚΑΛΩΔΙΟ ΟΠΤΙΚΗΣ ΙΝΑΣ
H --------------------
H HEIGHT
H ΥΨΟΣ
HH HANDHOLE
HH ΧΕΙΡΟΘΥΡΙΔΑ
I --------------------
IDF INTERMEDIATE DISTRIBUTION FRAME
IDF ΕΝΔΙΑΜΕΣΟ ΠΕΔΙΟ ΔΙΑΝΟΜΗΣ
J --------------------
JMPF JOINT MOBILITY PROCESS FACILITY
JMPF ΕΝΙΑΙΑ ΜΟΝΑΔΑ ΔΙΑΧΕΙΡΙΣΗΣ ΜΕΤΑΦΟΡΩΝ
M --------------------
MISC MISCELLANEOUS
MISC ΔΙΑΦΟΡΑ
MM MULTIMODE FIBER OPTIC CABLE
MM ΟΠΤΙΚΟ ΚΑΛΩΔΙΟ ΠΟΛΥΤΡΟΠΩΝ ΙΝΩΝ
mm MILLIMETER mm ΧΙΛΙΟΣΤΑ
MT,MTD MOUNT, MOUNTED
MT,MTD ΣΤΗΡΙΞΗ,ΤΟΠΟΘΕΤΗΜΕΝΟ ΣΕ
N --------------------
NA,N/A NOT APPLICABLE
NA,N/A ΔΕΝ ΕΧΕΙ ΕΦΑΡΜΟΓΗ
NEC NATIONAL ELECTRICAL CODE
NEC ΕΘΝΙΚΟΣ ΚΩΔΙΚΑΣ ΗΛΕΚΤΡΙΚΩΝ
NESC NATIONAL ELECTRICAL SAFETY CODE
NESC ΕΘΝΙΚΟΣ ΚΩΔΙΚΑΣ ΑΣΦΑΛΕΙΑΣ ΗΛΕΚΤΡΙΚΩΝ
NIPRNET NON-CLASSIFIED INTERNET PROTOCOL
ROUTER NETWORK
NIPRNET ΜΗ ΔΙΑΒΑΘΜΙΣΜΕΝΟ ΠΡΩΤΟΚΟΛΛΟ
ΔΙΑΔΥΚΤΙΟΥ ΔΡΟΜΟΛΟΓΗΣΗΣ ΔΙΚΤΥΩΝ
O --------------------
OC ON CENTER
OC ΣΤΟ ΚΕΝΤΡΟ
OSP OUTSIDE PLANT
OSP ΕΞΩΤΕΡΙΚΟ ΔΙΚΤΥΟ
P --------------------
PET PROTECTION ENTRANCE TERMINAL
PET ΤΕΡΜΑΤΙΚΟ ΠΡΟΣΤΑΣΙΑΣ ΕΙΣΟΔΟΥ
PNL PANEL
PNL ΠΙΝΑΚΑΣ
Q --------------------
QTY,# QUANTITY
QTY,# ΠΟΣΟΤΗΤΑ
R --------------------
RM ROOM
RM ΔΩΜΑΤΙΟ / ΧΩΡΟΣ
S --------------------
SC TYPE OF FIBER OPTIC CONNECTOR
APPROVED BY: PAM COWDEN, P.E.
1 2 3 4 5 5.1 65.9 7 8 9 10 11 12 13 14 14.4 15 16
14.814.514.212.412.310.5
J
H.5
H
G
F
E
D
C
B
A
CA
CB
CC
CD
CE
CF
CG
CH J.5
CC.7
K
SECTOR A
ΤΟΜΕΑΣ Α
SHEET T-111
ΣΧΕΔΙΟ Τ-111
SECTOR B
ΤΟΜΕΑΣ Β
SHEET T-112
ΣΧΕΔΙΟ Τ-112
SECTOR D
ΤΟΜΕΑΣ D
SHEET T-114
ΣΧΕΔΙΟ Τ-114
SECTOR C
ΤΟΜΕΑΣ C
SHEET T-113
ΣΧΕΔΙΟ Τ-113
SECTOR E
ΤΟΜΕΑΣ Ε
SHEET T-115
ΣΧΕΔΙΟ Τ-115
SECTOR F
ΤΟΜΕΑΣ F
SHEET T-116
ΣΧΕΔΙΟ T-116
SECTOR H
ΤΟΜΕΑΣ Η
SHEET T-118
ΣΧΕΔΙΟ Τ-118
SECTOR G
ΤΟΜΕΑΣ G
SHEET T-117
ΣΧΕΔΙΟ T-117
COMM RM 143 IDF-2
ΧΩΡΟΣ ΕΠΙΚΟΙΝΩΝΙΩΝ
RM 143 IDF-2
COMM RM 110 MDF-1
ΧΩΡΟΣ ΕΠΙΚΟΙΝΩΝΙΩΝ
RM 110 MDF-1
E.1
G.7
E.2
SM
G H C D
B A
EF
1 5 8 14 16
CA
CB
CE
CH
CG
B
C
K
G
D
C
B
1 2 3 4 5
1568016
DWG
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.
SCALE:
N62470-23-C-XXXX
RICHARD L STEPHENS, P.E.
LMM/MWL
CHIEF ENG/ARCH
DES DRW CHK
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
S O
U D
A B
A
YA KEYPLAN:
ΣΧΕΔΙΟ ΚΛΕΙΔΙ:
DRAWFORM REVISION: 25 AUGUST 2020
1 2 3 4 5
D
C
B
A
UNCLASSIFIED
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
A T
L A
N T
IC
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
N O
R F
O L K
V
A L A
N T
C A
P
IT
A L I M
P R
O V
E M
E N
T S
BRANCH MANAGER
PM/DM
SATISFACTORY TO DATE
FIRE PROTECTION DPS (DOUG STULTZ)
SEK (SOLVEIGH KEENE)
1 : 300
/3
/2
:1 :2
A
M
C R e v it L o c a l_ M o d e ls \2
\P
-1
-T R d ia n e .r io s E
Z M
N
.r v t
03/31/2023
T-110
MA DR JH
P J
O
IN
T M
O B
IL
IT
Y P
R O
C E
S S
IN
G
F A
C
IL
IT
Y
S O
U D
A B
A Y
G
R E
E C
E
F L
O O
R P
L A
N
L E
V E
L
O
V E
R A
L L
C
A B
L E
T R
A Y
14068907
T -1
Κ Α
Τ Ο
Ψ Η
-Ε Π
ΙΠ
Ε
Δ Ο
Σ Υ
Ν Ο
Λ
ΙΚ
Ο
Σ Χ
Α Ρ
Ε Σ
Κ Α
Λ Ω
Δ
ΙΩ
Ν
0 15000 30000
MILLIMETRESSCALE 1:300
90003000
PLAN NORTH
ΚΑΤΟΨΗ ΒΟΡΡΑ
A. SEE T-001 & T-002 FOR LEGEND, ABBREVIATIONS AND
GENERAL NOTES.
ΒΛΕΠΕ Τ-001 & Τ-002 ΓΙΑ ΥΠΟΜΝΗΜΑ, ΣΥΝΤΜΗΣΕΙΣ
ΚΑΙ ΓΕΝΙΚΕΣ ΠΑΡΑΤΗΡΗΣΕΙΣ
GENERAL NOTES:
ΓΕΝΙΚΕΣ ΠΑΡΑΤΗΡΗΣΕΙΣ:
SCALE: 1 : 300
FLOOR PLAN - LEVEL 1 - OVERALL - CABLE TRAY
ΚΑΤΟΨΗ - ΕΠΙΠΕΔΟ 1- ΣΥΝΟΛΙΚΟ- ΣΧΑΡΕΣ ΚΑΛΩΔΙΩΝ
APPROVED BY: PAM COWDEN, P.E.
SSSS
SSSSS
SSSSS
SSSSS
S
M A
T C
H L
IN
E
S E
E S
H E
E T
T -1
Γ Ρ
Α Μ
Μ Η
Σ Υ
Ν Α
Ρ Μ
Ο Γ Η
Σ Β
Λ Ε
Π Ε
Σ Χ
Ε Δ
ΙΟ
T
-1
MATCHLINE SEE SHEET T-114
ΓΡΑΜΜΗ ΣΥΝΑΡΜΟΓΗΣ ΒΛΕΠΕ
ΣΧΕΔΙΟ T-114
14 14.4 15 1614.814.514.2
J
H
G
GATE 1
GATE 2
GATE 3
AP
AP
AP
AP
TV TV
TV
TV TV
TV
TV TV
J.5
D O
W N
K
DOWN
UP
300mm x 100mm
H = 3720mmCT
300mm x 100mm
H = 3720mmCT
300mm x 100mm
H = 3720mmCT
300mm x 100mm
H = 3650mmCT
300mm x 100mm
H = 3720mmCT
300mm x 100mm
H = 4050mmCT
300mm x 100mm
H = 4230mmCT
UP DOWN
300mm x 100mm
H = 3720mmCT
300mm x 100mm
H = 3180mmCT
3 3
SM
A
1 5 8 14 16
CA
CB
CE
CH
CG
B
C
K
G
D
C
B
1 2 3 4 5
1568016
DWG
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.
SCALE:
N62470-23-C-XXXX
RICHARD L STEPHENS, P.E.
LMM/MWL
CHIEF ENG/ARCH
DES DRW CHK
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
S O
U D
A B
A Y
SHEET KEYED NOTES:
ΠΑΡΑΤΗΡΗΣΕΙΣ ΣΧΕΔΙΟΥ:
GENERAL NOTES:
ΓΕΝΙΚΕΣ ΠΑΡΑΤΗΡΗΣΕΙΣ:
A KEYPLAN:
ΣΧΕΔΙΟ ΚΛΕΙΔΙ:
DRAWFORM REVISION: 25 AUGUST 2020
1 2 3 4 5
D
C
B
A
UNCLASSIFIED
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
A T
L A
N T
IC
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
N O
R F
O L K
V
A L A
N T
C A
P
IT
A L I M
P R
O V
E M
E N
T S
BRANCH MANAGER
PM/DM
SATISFACTORY TO DATE
FIRE PROTECTION DPS (DOUG STULTZ)
SEK (SOLVEIGH KEENE)
1 : 100
/3
/2
:1 :5
A
M
C R e v it L o c a l_ M o d e ls \2
\P
-1
-T R d ia n e .r io s E
Z M
N
.r v t
03/31/2023
T-111
MA DR JH
P J
O
IN
T M
O B
IL
IT
Y P
R O
C E
S S
IN
G
F A
C
IL
IT
Y
S O
U D
A B
A Y
G
R E
E C
E
F L
O O
R P
L A
N
L E
V E
L
S
E C
T O
R A
T
E L
E C
O M
14068908
T -1
Κ Α
Τ Ο
Ψ Η
Ε
Π
ΙΠ
Ε Δ
Ο
Τ Ο
Μ Ε
Α Σ
Α
Τ Η
Λ Ε
Π
ΙΚ
Ο
ΙΝ
Ω Ν
ΙΕ
Σ
SCALE: 1 : 100
FLOOR PLAN - LEVEL 1 - SECTOR A - TELECOM
ΚΑΤΟΨΗ - ΕΠΙΠΕΔΟ 1 - ΤΟΜΕΑΣ Α - ΤΗΛΕΠΙΚΟΙΝΩΝΙΕΣ 0 5000 10000
MILLIMETRESSCALE 1:100
30001000
PLAN NORTH
ΚΑΤΟΨΗ ΒΟΡΡΑ
A. SEE T-001 & T-002 FOR LEGEND, ABBREVIATIONS AND
GENERAL NOTES.
ΒΛΕΠΕ Τ-001 & Τ-002 ΓΙΑ ΥΠΟΜΝΗΜΑ, ΣΥΝΤΜΗΣΕΙΣ
ΚΑΙ ΓΕΝΙΚΕΣ ΠΑΡΑΤΗΡΗΣΕΙΣ
B. SEE SHEET T-002 FOR TELECOMMUNICATION DEVICE
MOUNTING HEIGHTS UNLESS OTHERWISE NOTED.
ΒΛΕΠΕ ΣΧΕΔΙΟ Τ-002 ΓΙΑ ΥΨΗ ΤΟΠΟΘΕΤΗΣΗΣ
ΤΗΛΕΠΙΚΟΙΝΩΝΙΑΚΩΝ ΣΥΣΚΕΥΩΝ ΕΚΤΟΣ ΑΝ ΑΝΑΓΡΑΦΕΤΑΙ
ΔΙΑΦΟΡΕΤΙΚΑ
C. PROVIDE 300-MILLIMETER WIDE BY 100-MILLIMETER HIGH
SLOTTED BOTTOM WIRE BASKET CABLE TRAY FOR
TELECOMMUNICATIONS HORIZONTAL CABLING. SEE SHEET
T-505, DETAIL C1 FOR TRAY INSTALLATION (TYP).
ΠΡΟΜΗΘΕΥΣΤΕ ΣΧΑΡΑ ΚΑΛΩΔΙΩΝ ΣΥΡΜΑΤΙΝΟΥ ΠΛΕΓΜΑΤΟΣ
ΜΕ ΔΙΑΤΡΗΤΟ ΚΑΤΩ ΜΕΡΟΣ, ΠΛΑΤΟΥΣ 300mm x 100mm
ΥΨΟΥΣ ΓΙΑ ΤΗΝ ΟΡΙΖΟΝΤΙΑ ΚΑΛΩΔΙΩΣΗ ΤΗΛΕΠΙΚΟΙΝΩΝΙΩΝ.
ΒΛΕΠΕ ΣΧΕΔΙΟ Τ-505, ΛΕΠΤΟΜΕΡΕΙΑ C1 ΓΙΑ ΤΟΠΟΘΕΤΗΣΗ
ΣΧΑΡΑΣ (ΤΥΡ)
GENERAL NOTES:
ΓΕΝΙΚΕΣ ΠΑΡΑΤΗΡΗΣΕΙΣ:
1. PROVIDE FURNITURE MOUNTED DATA OUTLET. TYPICAL FOR
ALL OUTLETS MOUNTED INSIDE CASEWORK. SEE SHEET
T-503, DETAIL C3.
ΠΡΟΜΗΘΕΥΣΑΤΕ ΠΡΙΖΕΣ ΔΕΔΟΜΕΝΩΝ ΤΟΠΟΘΕΤΗΜΕΝΕΣ
ΠΑΝΩ ΣΤΑ ΕΠΙΠΛΑ. ΤΥΠΙΚΟ ΓΙΑ ΟΛΕΣ ΤΙΣ ΠΡΙΖΕΣ ΠΟΥ
ΤΟΠΟΘΕΤΟΥΝΤΑΙ ΕΝΤΟΣ ΚΑΤΑΣΚΕΥΩΝ. ΒΛΕΠΕ ΣΧΕΔΙΟ Τ-503
ΛΕΠΤΟΜΕΡΕΙΑ C3.
2. PROVIDE MODULAR PATHWAY SYSTEM. MODULAR PATHWAY
SYSTEM TO BE THE SAME OR LARGER CABLE VOLUME OF
CABLE TRAY. SEE DRAWING T-505.
ΠΑΡΕΧΕΤΕ ΣΥΣΤΗΜΑ ΟΔΕΥΣΗΣ ΚΑΛΩΔΙΩΝ .ΤΟ ΣΥΣΤΗΜΑ
ΟΔΕΥΣΗΣ ΚΑΛΩΔΙΩΝ ΝΑ ΕΙΝΑΙ ΤΟ ΙΔΙΟ Η ΜΕΓΑΛΥΤΕΡΟ ΑΠΟ
ΤΟΝ ΟΓΚΟ ΚΑΛΩΔΙΩΝ ΤΗΣ ΣΧΑΡΑΣ. ΔΕΣ ΣΧΕΔΙΟ Τ-505
3. INSTALL TV OUTLET AT 2250mm AFF.
ΤΟΠΟΘΕΤΗΣΤΕ ΤΗΝ ΠΡΙΖΑ ΤV 2250mm AFF
APPROVED BY: PAM COWDEN, P.E.
S
S
S
S
S
S
SS
S S
S
S
S
S
M A
T C
H L
IN
E
S E
E S
H E
E T
T -1
Γ Ρ
Α Μ
Μ Η
Σ Υ
Ν Α
Ρ Μ
Ο Γ Η
Σ Β
Λ Ε
Π Ε
Σ Χ
Ε Δ
ΙΟ
T
-1
MATCHLINE SEE SHEET T-113
ΓΡΑΜΜΗ ΣΥΝΑΡΜΟΓΗΣ ΒΛΕΠΕ
ΣΧΕΔΙΟ T-113
M A
T C
H L
IN
E
S E
E S
H E
E T
T -1
Γ Ρ
Α Μ
Μ Η
Σ Υ
Ν Α
Ρ Μ
Ο Γ Η
Σ Β
Λ Ε
Π Ε
Σ Χ
Ε Δ
ΙΟ
T
-1
AP
8 9 10 11 12 13 1412.412.310.5
J
H.5
H
G
CF
CG
CH
GATE 3
SPEC CAT CORR
SPEC CAT RR
SPEC CAT
BAGGAGE
BREAKDOWN
STAIR 2
BAGGAGE CLAIM
BAGGAGE
BUILDUP
LOST & FOUND
CUSTOMS AND
IMMIGRATION
AP
TV
TV
TV
J.5
K
UP
300mm x 100mm
H = 3690mmCT
300mm x 100mm
H = 3630mmCT
300mm x 100mm
H = 3725mmCT
300mm x 100mm
H = 3725mmCT
300mm x 100mm
H = 3725mmCT
300mm x 100mm
H = 4000mmCT
300mm x 100mm
H = 3200mmCT
UP
DOWN
U P
D O
W N
300mm x 100mm
H = 3200mmCT
300mm x 100mm
H = 3200mmCT
300mm x 100mm
H = 4050mmCT
3 3
G.7
SM
B
1 5 8 14 16
CA
CB
CE
CH
CG
B
C
K
G
D
C
B
1 2 3 4 5
1568016
DWG
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.
SCALE:
N62470-23-C-XXXX
RICHARD L STEPHENS, P.E.
LMM/MWL
CHIEF ENG/ARCH
DES DRW CHK
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
S O
U D
A B
A Y
SHEET KEYED NOTES:
ΠΑΡΑΤΗΡΗΣΕΙΣ ΣΧΕΔΙΟΥ:
GENERAL NOTES:
ΓΕΝΙΚΕΣ ΠΑΡΑΤΗΡΗΣΕΙΣ:
A KEYPLAN:
ΣΧΕΔΙΟ ΚΛΕΙΔΙ:
DRAWFORM REVISION: 25 AUGUST 2020
1 2 3 4 5
D
C
B
A
UNCLASSIFIED
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
A T
L A
N T
IC
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
N O
R F
O L K
V
A L A
N T
C A
P
IT
A L I M
P R
O V
E M
E N
T S
BRANCH MANAGER
PM/DM
SATISFACTORY TO DATE
FIRE PROTECTION DPS (DOUG STULTZ)
SEK (SOLVEIGH KEENE)
1 : 100
/3
/2
:2 :0
A
M
C R e v it L o c a l_ M o d e ls \2
\P
-1
-T R d ia n e .r io s E
Z M
N
.r v t
03/31/2023
T-112
MA DR JH
P J
O
IN
T M
O B
IL
IT
Y P
R O
C E
S S
IN
G
F A
C
IL
IT
Y
S O
U D
A B
A Y
G
R E
E C
E
F L
O O
R P
L A
N
L E
V E
L
S
E C
T O
R B
T
E L
E C
O M
14068909
T -1
Κ Α
Τ Ο
Ψ Η
Ε
Π
ΙΠ
Ε Δ
Ο
Τ Ο
Μ Ε
Α Σ
Β
Τ Η
Λ Ε
Π
ΙΚ
Ο
ΙΝ
Ω Ν
ΙΕ
Σ
SCALE: 1 : 100
FLOOR PLAN - LEVEL 1 - SECTOR B - TELECOM
ΚΑΤΟΨΗ - ΕΠΙΠΕΔΟ - 1 - ΤΟΜΕΑΣ Β - ΤΗΛΕΠΙΚΟΙΝΩΝΙΕΣ 0 5000 10000
MILLIMETRESSCALE 1:100
30001000
PLAN NORTH
ΚΑΤΟΨΗ ΒΟΡΡΑ
1. PROVIDE FURNITURE MOUNTED DATA OUTLET. TYPICAL FOR
ALL OUTLETS MOUNTED INSIDE CASEWORK. SEE SHEET
T-503, DETAIL C3.
ΠΡΟΜΗΘΕΥΣΑΤΕ ΠΡΙΖΕΣ ΔΕΔΟΜΕΝΩΝ ΤΟΠΟΘΕΤΗΜΕΝΕΣ
ΠΑΝΩ ΣΤΑ ΕΠΙΠΛΑ. ΤΥΠΙΚΟ ΓΙΑ ΟΛΕΣ ΤΙΣ ΠΡΙΖΕΣ ΠΟΥ
ΤΟΠΟΘΕΤΟΘΝΤΑΙ ΕΝΤΟΣ ΚΑΤΑΣΚΕΥΩΝ. ΒΛΕΠΕ ΣΧΕΔΙΟ Τ-503
ΛΕΠΤΟΜΕΡΕΙΑ C3.
2. INSTALL TV OUTLET AT 1829mm AFF.
ΤΟΠΟΘΕΤΗΣΤΕ ΤΗΝ ΠΡΙΖΑ ΤV 1829mm AFF
3. PROVIDE MODULAR PATHWAY SYSTEM. MODULAR PATHWAY
SYSTEM TO BE THE SAME OR LARGER CABLE VOLUME OF
CABLE TRAY. SEE DRAWING T-505.
ΠΑΡΕΧΕΤΕ ΣΥΣΤΗΜΑ ΟΔΕΥΣΗΣ ΚΑΛΩΔΙΩΝ .ΤΟ ΣΥΣΤΗΜΑ
ΟΔΕΥΣΗΣ ΚΑΛΩΔΙΩΝ ΝΑ ΕΙΝΑΙ ΤΟ ΙΔΙΟ Η ΜΕΓΑΛΥΤΕΡΟ ΑΠΟ
ΤΟΝ ΟΓΚΟ ΚΑΛΩΔΙΩΝ ΤΗΣ ΣΧΑΡΑΣ. ΔΕΣ ΣΧΕΔΙΟ Τ-505
4. INSTALL TV OUTLET AT 2250mm AFF.
ΕΓΚΑΤΑΣΤΗΣΤΕ ΤΗΝ ΠΡΙΖΑ ΤΗΛΕΟΡΑΣΗΣ ΣΤΑ 2250 MM AFF
A. SEE T-001 & T-002 FOR LEGEND, ABBREVIATIONS AND
GENERAL NOTES.
ΒΛΕΠΕ Τ-001 & Τ-002 ΓΙΑ ΥΠΟΜΝΗΜΑ, ΣΥΝΤΜΗΣΕΙΣ
ΚΑΙ ΓΕΝΙΚΕΣ ΠΑΡΑΤΗΡΗΣΕΙΣ
B. SEE SHEET T-002 FOR TELECOMMUNICATION DEVICE
MOUNTING HEIGHTS UNLESS OTHERWISE NOTED.
ΒΛΕΠΕ ΣΧΕΔΙΟ Τ-002 ΓΙΑ ΥΨΗ ΤΟΠΟΘΕΤΗΣΗΣ
ΤΗΛΕΠΙΚΟΙΝΩΝΙΑΚΩΝ ΣΥΣΚΕΥΩΝ ΕΚΤΟΣ ΑΝ ΑΝΑΓΡΑΦΕΤΑΙ
ΔΙΑΦΟΡΕΤΙΚΑ
C. PROVIDE 300-MILLIMETER WIDE BY 100-MILLIMETER HIGH
SLOTTED BOTTOM WIRE BASKET CABLE TRAY FOR
TELECOMMUNICATIONS HORIZONTAL CABLING. SEE SHEET
T-505, DETAIL C1 FOR TRAY INSTALLATION (TYP).
ΠΡΟΜΗΘΕΥΣΤΕ ΣΧΑΡΑ ΚΑΛΩΔΙΩΝ ΣΥΡΜΑΤΙΝΟΥ ΠΛΕΓΜΑΤΟΣ
ΜΕ ΔΙΑΤΡΗΤΟ ΚΑΤΩ ΜΕΡΟΣ, ΠΛΑΤΟΥΣ 300mm x 100mm
ΥΨΟΥΣ ΓΙΑ ΤΗΝ ΟΡΙΖΟΝΤΙΑ ΚΑΛΩΔΙΩΣΗ ΤΗΛΕΠΙΚΟΙΝΩΝΙΩΝ.
ΒΛΕΠΕ ΣΧΕΔΙΟ Τ-505, ΛΕΠΤΟΜΕΡΕΙΑ C1 ΓΙΑ ΤΟΠΟΘΕΤΗΣΗ
ΣΧΑΡΑΣ (ΤΥΡ)
APPROVED BY: PAM COWDEN, P.E.
SS
S S S S
S
S S
S
M A
T C
H L
IN
E
S E
E S
H E
E T
T -1
Γ Ρ
Α Μ
Μ Η
Σ Υ
Ν Α
Ρ Μ
Ο Γ Η
Σ Β
Λ Ε
Π Ε
Σ Χ
Ε Δ
ΙΟ
T
-1
MATCHLINE SEE SHEET T-112
ΓΡΑΜΜΗ ΣΥΝΑΡΜΟΓΗΣ ΒΛΕΠΕ
ΣΧΕΔΙΟ T-112
M A
T C
H L
IN
E
S E
E S
H E
E T
T -1
Γ Ρ
Α Μ
Μ Η
Σ Υ
Ν Α
Ρ Μ
Ο Γ Η
Σ Β
Λ Ε
Π Ε
Σ Χ
Ε Δ
ΙΟ
T
-1
M A
T C
H L
IN
E
S E
E S
H E
E T
T -1
Γ Ρ
Α Μ
Μ Η
Σ Υ
Ν Α
Ρ Μ
Ο Γ Η
Σ Β
Λ Ε
Π Ε
Σ Χ
Ε Δ
ΙΟ
T
-1
8 9 10 11 12 13 1412.3
G
F
E
D
C
B
A
CB
CC
CD
CE
CF
VEST
LOBBY
PAX
SECURITY
CORR
BAGGAGE
BUILDUP
CUSTOMS OFC
AG OFC
CUSTOMS AND
IMMIGRATION
TVTV
TV
CC.7
1 2
3 3
AP
AP
AP
APAP
AP
AP
300mm x 100mm
H = 3200mmCT
300mm x 100mm
H = 3200mmCT
300mm x 100mm
H = 3200mmCT
300mm x 100mm
H = 3860mmCT
300mm x 100mm
H = 3890mmCT
300mm x 100mm
H = 3200mmCT
U P
U P
E.2
4 4
7 4 7 4 7
8 8
SM
C
1 5 8 14 16
CA
CB
CE
CH
CG
B
C
K
G
D
C
B
1 2 3 4 5
1568016
DWG
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.
SCALE:
N62470-23-C-XXXX
RICHARD L STEPHENS, P.E.
LMM/MWL
CHIEF ENG/ARCH
DES DRW CHK
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
S O
U D
A B
A Y
SHEET KEYED NOTES:
ΠΑΡΑΤΗΡΗΣΕΙΣ ΣΧΕΔΙΟΥ:
GENERAL NOTES:
ΓΕΝΙΚΕΣ ΠΑΡΑΤΗΡΗΣΕΙΣ:
A KEYPLAN:
ΣΧΕΔΙΟ ΚΛΕΙΔΙ:
DRAWFORM REVISION: 25 AUGUST 2020
1 2 3 4 5
D
C
B
A
UNCLASSIFIED
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
A T
L A
N T
IC
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
N O
R F
O L K
V
A L A
N T
C A
P
IT
A L I M
P R
O V
E M
E N
T S
BRANCH MANAGER
PM/DM
SATISFACTORY TO DATE
FIRE PROTECTION DPS (DOUG STULTZ)
SEK (SOLVEIGH KEENE)
1 : 100
/3
/2
:2 :2
A
M
C R e v it L o c a l_ M o d e ls \2
\P
-1
-T R d ia n e .r io s E
Z M
N
.r v t
03/31/2023
T-113
MA DR JH
P J
O
IN
T M
O B
IL
IT
Y P
R O
C E
S S
IN
G
F A
C
IL
IT
Y
S O
U D
A B
A Y
G
R E
E C
E
F L
O O
R P
L A
N
L E
V E
L
S
E C
T O
R C
T
E L
E C
O M
14068910
T -1
Κ Α
Τ Ο
Ψ Η
Ε
Π
ΙΠ
Ε Δ
Ο
Τ Ο
Μ Ε
Α Σ
C
Τ Η
Λ Ε
Π
ΙΚ
Ο
ΙΝ
Ω Ν
ΙΕ
Σ
SCALE: 1 : 100
FLOOR PLAN - LEVEL 1 - SECTOR C - TELECOM
ΚΑΤΟΨΗ - ΕΠΙΠΕΔΟ 1- ΤΟΜΕΑΣ C - ΤΗΛΕΠΙΚΟΙΝΩΝΙΕΣ 0 5000 10000
MILLIMETRESSCALE 1:100
30001000
PLAN NORTH
ΚΑΤΟΨΗ ΒΟΡΡΑ
1. COORDINATE FLOOR MOUNTED TELECOM OUTLETS WITH
ELECTRICAL DURING INSTALLATION. FLOOR BOX WILL BE
SUPPLIED BY ELECTRICAL.
ΣΥΝΤΟΝΙΣΤΕ ΤΗΝ ΤΟΠΟΘΕΤΗΣΗ ΤΩΝ ΕΠΙΔΑΠΕΔΙΩΝ
ΤΗΛ/ΚΩΝ ΠΡΙΖΩΝ ΜΕ ΤΑ ΗΛΕΚΤΡΙΚΑ ΚΑΤΑ ΤΗΝ ΔΙΑΡΚΕΙΑ
ΤΗΣ ΕΓΚΑΤΑΣΤΑΣΗΣ. ΤΑ ΕΝΔΟΔΑΠΕΔΙΑ ΚΟΥΤΙΑ
ΠΡΟΜΗΘΕΥΟΝΤΑΙ ΜΕ ΤΟΝ ΗΛΕΚΤΡΟΛΟΓΙΚΟ ΕΞΟΠΛΙΣΜΟ
2. COORDINATE WITH EQUIPMENT MANUFACTURER AND
ELECTRICAL TO DETERMINE MOUNTING REQUIREMENTS.
ΣΥΝΤΟΝΙΣΤΕ ΜΕ ΤΟΝ ΚΑΤΑΣΚΕΥΑΣΤΗ ΕΞΟΠΛΙΣΜΟΥ ΚΑΙ ΤΑ
ΗΛΕΚΤΡΙΚΑ ΓΙΑ ΤΟΝ ΠΡΟΣΔΙΟΡΙΣΜΟ ΑΠΑΙΤΗΣΕΩΝ
ΤΟΠΟΘΕΤΗΣΗΣ.
3. ROUTE 25mm CONDUIT FROM FLOOR BOX TO ADJACENT
WALL AND EXTEND CONDUIT UP INSIDE THE WALL AND
ROUTE TO NEAREST TELECOM CABLE TRAY.
ΧΡΗΣΙΜΟΠΟΙΗΣΤΕ ΣΩΛΗΝΑ ΚΑΛΩΔΙΩΝ 25mm ΑΠΟ ΤΟ
ΕΠΙΔΑΠΕΔΙΟ ΚΟΥΤΙ ΠΡΟΣ ΤΟΝ ΔΙΠΛΑΝΟ ΤΟΙΧΟ ΚΑΙ
ΕΚΤΕΙΝΕΤΑΙ ΠΡΟΣ ΤΑ ΠΑΝΩ ΕΝΤΟΣ ΤΟΥ ΤΟΙΧΟΥ ΕΩΣ ΤΗΝ
ΠΛΗΣΙΕΣΤΕΡΗ ΣΧΑΡΑ ΤΗΛΕΠΙΚΟΙΝΩΝΙΑΚΩΝ ΚΑΛΩΔΙΩΝ
4. PROVIDE FURNITURE MOUNTED DATA OUTLET. TYPICAL FOR
ALL OUTLETS MOUNTED INSIDE CASEWORK. SEE SHEET
T-503, DETAIL C3.
ΠΡΟΜΗΘΕΥΣΑΤΕ ΠΡΙΖΕΣ ΔΕΔΟΜΕΝΩΝ ΤΟΠΟΘΕΤΗΜΕΝΕΣ
ΠΑΝΩ ΣΤΑ ΕΠΙΠΛΑ. ΤΥΠΙΚΟ ΓΙΑ ΟΛΕΣ ΤΙΣ ΠΡΙΖΕΣ ΠΟΥ
ΤΟΠΟΘΕΤΟΘΝΤΑΙ ΕΝΤΟΣ ΚΑΤΑΣΚΕΥΩΝ. ΒΛΕΠΕ ΣΧΕΔΙΟ Τ-503
ΛΕΠΤΟΜΕΡΕΙΑ C3.
5. SPEAKERS AND ACCESS POINT DEVICES ARE MOUNTED
TO CEILING CLOUDS AND CEILINGS IN LOBBY ROOM 101.
REFER TO ARCHITECTURAL DRAWING A-133 FOR
SPECIFICATIONS. REFER TO T-504, DETAIL A3 FOR
MOUNTING INSTRUCTIONS.
ΤΑ ΗΧΕΙΑ ΚΑΙ ΟΙ ΣΥΣΚΕΥΕΣ ΣΗΜΕΙΩΝ ΠΡΟΣΒΑΣΗΣ
ΤΟΠΟΘΕΤΟΥΝΤΑΙ ΣΤΙΣ ΑΝΑΡΤΟΥΜΕΝΕΣ ΟΡΟΦΕΣ ΤΥΠΟΥ
ΣΥΝΝΕΦΟ ΚΑΙ ΟΡΟΦΕΣ ΣΤHN ΑΙΘΟΥΣΑ ΑΝΑΜΟΝΗΣ ΧΩΡΟΣ
101. ΑΝΑΤΡΕΞΤΕ ΣΤO ΑΡΧΙΤΕΚΤΟΝΙΚO ΣΧΕΔΙO Α-133 ΓΙΑ
ΠΡΟΔΙΑΓΡΑΦΕΣ. ΑΝΑΤΡΕΞΤΕ ΣΤΟ Τ-504, ΛΕΠΤΟΜΕΡΕΙΑ A3
ΓΙΑ ΟΔΗΓΙΕΣ ΤΟΠΟΘΕΤΗΣΗΣ
6. PROVIDE MODULAR PATHWAY SYSTEM. MODULAR PATHWAY
SYSTEM TO BE THE SAME OR LARGER CABLE VOLUME OF
CABLE TRAY. SEE DRAWING T-505.
ΠΑΡΕΧΕΤΕ ΣΥΣΤΗΜΑ ΟΔΕΥΣΗΣ ΚΑΛΩΔΙΩΝ .ΤΟ ΣΥΣΤΗΜΑ
ΟΔΕΥΣΗΣ ΚΑΛΩΔΙΩΝ ΝΑ ΕΙΝΑΙ ΤΟ ΙΔΙΟ Η ΜΕΓΑΛΥΤΕΡΟ ΑΠΟ
ΤΟΝ ΟΓΚΟ ΚΑΛΩΔΙΩΝ ΤΗΣ ΣΧΑΡΑΣ. ΔΕΣ ΣΧΕΔΙΟ Τ-505
7. OUTLET NEEDS FOUR (4) CAT6.
Η ΠΡΙΖΑ ΑΠΑΙΤΕΙ ΤΕΣΣΕΡΑ (4) CAT6.
8. INSTALL TV OUTLET AT 1829mm AFF.
ΕΓΚΑΤΑΣΤΗΣΤΕ ΤΗΝ ΠΡΙΖΑ ΤΗΛΕΟΡΑΣΗΣ ΣΤΑ 1829 MM AFF
9. INSTALL TV OUTLET AT 2250mm AFF.
ΕΓΚΑΤΑΣΤΗΣΤΕ ΤΗΝ ΠΡΙΖΑ ΤΗΛΕΟΡΑΣΗΣ ΣΤΑ 2250 MM AFF
A. SEE T-001 & T-002 FOR LEGEND, ABBREVIATIONS AND
GENERAL NOTES.
ΒΛΕΠΕ Τ-001 & Τ-002 ΓΙΑ ΥΠΟΜΝΗΜΑ, ΣΥΝΤΜΗΣΕΙΣ
ΚΑΙ ΓΕΝΙΚΕΣ ΠΑΡΑΤΗΡΗΣΕΙΣ
B. SEE SHEET T-002 FOR TELECOMMUNICATION DEVICE
MOUNTING HEIGHTS UNLESS OTHERWISE NOTED.
ΒΛΕΠΕ ΣΧΕΔΙΟ Τ-002 ΓΙΑ ΥΨΗ ΤΟΠΟΘΕΤΗΣΗΣ
ΤΗΛΕΠΙΚΟΙΝΩΝΙΑΚΩΝ ΣΥΣΚΕΥΩΝ ΕΚΤΟΣ ΑΝ ΑΝΑΓΡΑΦΕΤΑΙ
ΔΙΑΦΟΡΕΤΙΚΑ
C. PROVIDE 300-MILLIMETER WIDE BY 100-MILLIMETER HIGH
SLOTTED BOTTOM WIRE BASKET CABLE TRAY FOR
TELECOMMUNICATIONS HORIZONTAL CABLING. SEE SHEET
T-505, DETAIL C1 FOR TRAY INSTALLATION (TYP).
ΠΡΟΜΗΘΕΥΣΤΕ ΣΧΑΡΑ ΚΑΛΩΔΙΩΝ ΣΥΡΜΑΤΙΝΟΥ ΠΛΕΓΜΑΤΟΣ
ΜΕ ΔΙΑΤΡΗΤΟ ΚΑΤΩ ΜΕΡΟΣ, ΠΛΑΤΟΥΣ 300mm x 100mm
ΥΨΟΥΣ ΓΙΑ ΤΗΝ ΟΡΙΖΟΝΤΙΑ ΚΑΛΩΔΙΩΣΗ ΤΗΛΕΠΙΚΟΙΝΩΝΙΩΝ.
ΒΛΕΠΕ ΣΧΕΔΙΟ Τ-505, ΛΕΠΤΟΜΕΡΕΙΑ C1 ΓΙΑ ΤΟΠΟΘΕΤΗΣΗ
ΣΧΑΡΑΣ (ΤΥΡ)
APPROVED BY: PAM COWDEN, P.E.
S
SSS
S
S
M A
T C
H L
IN
E
S E
E S
H E
E T
T -1
Γ Ρ
Α Μ
Μ Η
Σ Υ
Ν Α
Ρ Μ
Ο Γ Η
Σ Β
Λ Ε
Π Ε
Σ Χ
Ε Δ
ΙΟ
T
-1
MATCHLINE SEE SHEET T-111
ΓΡΑΜΜΗ ΣΥΝΑΡΜΟΓΗΣ ΒΛΕΠΕ
ΣΧΕΔΙΟ T-111
AP
14 14.4 15 16
14.814.514.2
G
F
E
D
C
B
A
FUNDS
PAX
PSC
MECH
ELEC
CORR
MEN
WOMEN
COMM
FAMILY
MOTHER
WOMEN
MEN
ELEV
ELEV RM
STAIR 1
JAN
CORR
LOBBY
T-401
A2
AP
TV
TV
TV
RR
AP
EM
EM
JAN
W
W
TV
300mm x 100mm
H = 3420mmCT
300mm x 100mm
H = 3180mmCT
D O
W N
4 4
300mm x 100mm
H = 3180mmCT
1 1 1
W
E.1
SM
D
1 5 8 14 16
CA
CB
CE
CH
CG
B
C
K
G
D
C
B
1 2 3 4 5
1568016
DWG
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.
SCALE:
N62470-23-C-XXXX
RICHARD L STEPHENS, P.E.
LMM/MWL
CHIEF ENG/ARCH
DES DRW CHK
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
S O
U D
A B
A Y
SHEET KEYED NOTES:
ΠΑΡΑΤΗΡΗΣΕΙΣ ΣΧΕΔΙΟΥ:
GENERAL NOTES:
ΓΕΝΙΚΕΣ ΠΑΡΑΤΗΡΗΣΕΙΣ:
A KEYPLAN:
ΣΧΕΔΙΟ ΚΛΕΙΔΙ:
DRAWFORM REVISION: 25 AUGUST 2020
1 2 3 4 5
D
C
B
A
UNCLASSIFIED
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
A T
L A
N T
IC
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
N O
R F
O L K
V
A L A
N T
C A
P
IT
A L I M
P R
O V
E M
E N
T S
BRANCH MANAGER
PM/DM
SATISFACTORY TO DATE
FIRE PROTECTION DPS (DOUG STULTZ)
SEK (SOLVEIGH KEENE)
1 : 100
/3
/2
:2 :5
A
M
C R e v it L o c a l_ M o d e ls \2
\P
-1
-T R d ia n e .r io s E
Z M
N
.r v t
03/31/2023
T-114
MA DR JH
P J
O
IN
T M
O B
IL
IT
Y P
R O
C E
S S
IN
G
F A
C
IL
IT
Y
S O
U D
A B
A Y
G
R E
E C
E
F L
O O
R P
L A
N
L E
V E
L
S
E C
T O
R D
T
E L
E C
O M
14068911
T -1
Κ Α
Τ Ο
Ψ Η
Ε
Π
ΙΠ
Ε Δ
Ο
Τ Ο
Μ Ε
Α Σ
D
Τ Η
Λ Ε
Π
ΙΚ
Ο
ΙΝ
Ω Ν
ΙΕ
Σ
SCALE: 1 : 100
FLOOR PLAN - LEVEL 1 - SECTOR D - TELECOM
ΚΑΤΟΨΗ - ΕΠΙΠΕΔΟ 1 - ΤΟΜΕΑΣ D - ΤΗΛΕΠΙΚΟΙΝΩΝΙΕΣ 0 5000 10000
MILLIMETRESSCALE 1:100
30001000
PLAN NORTH
ΚΑΤΟΨΗ ΒΟΡΡΑ
1 ROUTE CATEGORY 6 CABLES TO DOWN COLUMN AND UNDER
THE COUNTER TO OUTLET LOCATIONS.
ΔΡΟΜΟΛΟΓΗΣΤΕ ΚΑΤΗΓΟΡΙΑΣ 6 ΚΑΛΩΔΙΑ ΣΤΗΝ ΚΟΛΩΝΑ ΠΟΥ
ΚΑΤΕΒΑΙΝΕΙ ΚΑΙ ΚΑΤΩ ΑΠΟ ΤΟΝ ΠΑΓΚΟ ΣΤΙΣ ΘΕΣΕΙΣ ΤΩΝ
ΠΡΙΖΩΝ.
2 COORDINATE ELEVATOR TELEPHONE CONNECTION WITH
ELEVATOR INSTALLER.
ΣΥΝΤΟΝΙΣΤΕ ΤΗ ΣΥΝΔΕΣΗ ΤΟΥ ΤΗΛΕΦΩΝΟΥ ΤΟΥ
ΑΝΕΛΚΥΣΤΗΡΑ ΜΕ ΤΟΝ ΕΓΚΑΤΑΣΤΑΤΗ ΤΟΥ ΑΝΕΛΚΥΣΤΗΡΑ.
3. SPEAKERS AND ACCESS POINT DEVICES ARE MOUNTED
TO CEILING CLOUDS AND CEILINGS IN LOBBY ROOM 101.
REFER TO ARCHITECTURAL DRAWING A-133 FOR
SPECIFICATIONS.
ΤΑ ΗΧΕΙΑ ΚΑΙ ΟΙ ΣΥΣΚΕΥΕΣ ΣΗΜΕΙΩΝ ΠΡΟΣΒΑΣΗΣ
ΤΟΠΟΘΕΤΟΥΝΤΑΙ ΣΤΙΣ ΑΝΑΡΤΟΥΜΕΝΕΣ ΟΡΟΦΕΣ ΤΥΠΟΥ
ΣΥΝΝΕΦΟ ΚΑΙ ΟΡΟΦΕΣ ΣΤHN ΑΙΘΟΥΣΑ ΑΝΑΜΟΝΗΣ ΧΩΡΟΣ
101. ΑΝΑΤΡΕΞΤΕ ΣΤO ΑΡΧΙΤΕΚΤΟΝΙΚO ΣΧΕΔΙO Α-133 ΓΙΑ
ΠΡΟΔΙΑΓΡΑΦΕΣ.
4. INSTALL TV OUTLET AT 1829mm AFF.
ΕΓΚΑΤΑΣΤΗΣΤΕ ΤΗΝ ΠΡΙΖΑ ΤΗΛΕΟΡΑΣΗΣ ΣΤΑ 1829 MM AFF
5. PROVIDE MODULAR PATHWAY SYSTEM. MODULAR PATHWAY
SYSTEM TO BE THE SAME OR LARGER CABLE VOLUME OF
CABLE TRAY. SEE DRAWING T-505.
ΠΑΡΕΧΕΤΕ ΣΥΣΤΗΜΑ ΟΔΕΥΣΗΣ ΚΑΛΩΔΙΩΝ .ΤΟ ΣΥΣΤΗΜΑ
ΟΔΕΥΣΗΣ ΚΑΛΩΔΙΩΝ ΝΑ ΕΙΝΑΙ ΤΟ ΙΔΙΟ Η ΜΕΓΑΛΥΤΕΡΟ ΑΠΟ
ΤΟΝ ΟΓΚΟ ΚΑΛΩΔΙΩΝ ΤΗΣ ΣΧΑΡΑΣ. ΔΕΣ ΣΧΕΔΙΟ Τ-505
6. INSTALL TV OUTLET AT 2250mm AFF.
ΕΓΚΑΤΑΣΤΗΣΤΕ ΤΗΝ ΠΡΙΖΑ ΤΗΛΕΟΡΑΣΗΣ ΣΤΑ 2250 MM AFF
A. SEE T-001 & T-002 FOR LEGEND, ABBREVIATIONS AND
GENERAL NOTES.
ΒΛΕΠΕ Τ-001 & Τ-002 ΓΙΑ ΥΠΟΜΝΗΜΑ, ΣΥΝΤΜΗΣΕΙΣ
ΚΑΙ ΓΕΝΙΚΕΣ ΠΑΡΑΤΗΡΗΣΕΙΣ
B. SEE SHEET T-002 FOR TELECOMMUNICATION DEVICE
MOUNTING HEIGHTS UNLESS OTHERWISE NOTED.
ΒΛΕΠΕ ΣΧΕΔΙΟ Τ-002 ΓΙΑ ΥΨΗ ΤΟΠΟΘΕΤΗΣΗΣ
ΤΗΛΕΠΙΚΟΙΝΩΝΙΑΚΩΝ ΣΥΣΚΕΥΩΝ ΕΚΤΟΣ ΑΝ ΑΝΑΓΡΑΦΕΤΑΙ
ΔΙΑΦΟΡΕΤΙΚΑ
C. PROVIDE 300-MILLIMETER WIDE BY 100-MILLIMETER HIGH
SLOTTED BOTTOM WIRE BASKET CABLE TRAY FOR
TELECOMMUNICATIONS HORIZONTAL CABLING. SEE SHEET
T-505, DETAIL C1 FOR TRAY INSTALLATION (TYP).
ΠΡΟΜΗΘΕΥΣΤΕ ΣΧΑΡΑ ΚΑΛΩΔΙΩΝ ΣΥΡΜΑΤΙΝΟΥ ΠΛΕΓΜΑΤΟΣ
ΜΕ ΔΙΑΤΡΗΤΟ ΚΑΤΩ ΜΕΡΟΣ, ΠΛΑΤΟΥΣ 300mm x 100mm
ΥΨΟΥΣ ΓΙΑ ΤΗΝ ΟΡΙΖΟΝΤΙΑ ΚΑΛΩΔΙΩΣΗ ΤΗΛΕΠΙΚΟΙΝΩΝΙΩΝ.
ΒΛΕΠΕ ΣΧΕΔΙΟ Τ-505, ΛΕΠΤΟΜΕΡΕΙΑ C1 ΓΙΑ ΤΟΠΟΘΕΤΗΣΗ
ΣΧΑΡΑΣ (ΤΥΡ)
APPROVED BY: PAM COWDEN, P.E.
S
S
S
S
S
S
S
S
S
S P
S P
S P
M A
T C
H L
IN
E
S E
E S
H E
E T
T -1
Γ Ρ
Α Μ
Μ Η
Σ Υ
Ν Α
Ρ Μ
Ο Γ Η
Σ Β
Λ Ε
Π Ε
Σ Χ
Ε Δ
ΙΟ
T
-1
MATCHLINE SEE SHEET T-118
ΓΡΑΜΜΗ ΣΥΝΑΡΜΟΓΗΣ ΒΛΕΠΕ
ΣΧΕΔΙΟ T-118
5.1 5.9 7 8 9
J
H.5
H
G
F
CE
CF
CG
CH
CARGO BAY
RR
RR
RR
CORR
SUPPLY OFC
BREAK
PARALOFT
T-LINE OFC
E-28
T-LINE
158 OFC
DET. MAIN. SPT
M A
T C
H L
IN
E
S E
E S
H E
E T
T -1
Γ Ρ
Α Μ
Μ Η
Σ Υ
Ν Α
Ρ Μ
Ο Γ Η
Σ Β
Λ Ε
Π Ε
Σ Χ
Ε Δ
ΙΟ
T
-1
1 J.5
AP
AP
AP
AP
AP
AP
D O
W N
300mm x 100mm
H = 3100mmCT
300mm x 100mm
H = 3100mmCT
300mm x 100mm
H = 3220mmCT
300mm x 100mm
H = 3100mmCT
G.7
SM
E
1 5 8 14 16
CA
CB
CE
CH
CG
B
C
K
G
D
C
B
1 2 3 4 5
1568016
DWG
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.
SCALE:
N62470-23-C-XXXX
RICHARD L STEPHENS, P.E.
LMM/MWL
CHIEF ENG/ARCH
DES DRW CHK
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
S O
U D
A B
A Y
SHEET KEYED NOTES:
ΠΑΡΑΤΗΡΗΣΕΙΣ ΣΧΕΔΙΟΥ:
GENERAL NOTES:
ΓΕΝΙΚΕΣ ΠΑΡΑΤΗΡΗΣΕΙΣ:
A KEYPLAN:
ΣΧΕΔΙΟ ΚΛΕΙΔΙ:
DRAWFORM REVISION: 25 AUGUST 2020
1 2 3 4 5
D
C
B
A
UNCLASSIFIED
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
A T
L A
N T
IC
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
N O
R F
O L K
V
A L A
N T
C A
P
IT
A L I M
P R
O V
E M
E N
T S
BRANCH MANAGER
PM/DM
SATISFACTORY TO DATE
FIRE PROTECTION DPS (DOUG STULTZ)
SEK (SOLVEIGH KEENE)
1 : 100
/3
/2
:2 :1
A
M
C R e v it L o c a l_ M o d e ls \2
\P
-1
-T R d ia n e .r io s E
Z M
N
.r v t
03/31/2023
T-115
MA DR JH
P J
O
IN
T M
O B
IL
IT
Y P
R O
C E
S S
IN
G
F A
C
IL
IT
Y
S O
U D
A B
A Y
G
R E
E C
E
F L
O O
R P
L A
N
L E
V E
L
S
E C
T O
R E
T
E L
E C
O M
14068912
T -1
Κ Α
Τ Ο
Ψ Η
Ε
Π
ΙΠ
Ε Δ
Ο
Τ Ο
Μ Ε
Α Σ
Ε
-Τ Η
Λ Ε
Π
ΙΚ
Ο
ΙΝ
Ω Ν
ΙΕ
Σ
SCALE: 1 : 100
FLOOR PLAN - LEVEL 1 - SECTOR E - TELECOM
ΚΑΤΟΨΗ - ΕΠΙΠΕΔΟ 1- ΤΟΜΕΑΣ Ε - ΤΗΛΕΠΙΚΟΙΝΩΝΙΕΣ 0 5000 10000
MILLIMETRESSCALE 1:100
30001000
PLAN NORTH
ΚΑΤΟΨΗ ΒΟΡΡΑ
1. COORDINATE FLOOR MOUNTED TELECOM OUTLETS WITH
ELECTRICAL DURING INSTALLATION. FLOOR BOX WILL BE
SUPPLIED BY ELECTRICAL.
ΣΥΝΤΟΝΙΣΤΕ ΤΗΝ ΤΟΠΟΘΕΤΗΣΗ ΤΩΝ ΕΠΙΔΑΠΕΔΙΩΝ
ΤΗΛ/ΚΩΝ ΠΡΙΖΩΝ ΜΕ ΤΑ ΗΛΕΚΤΡΙΚΑ ΚΑΤΑ ΤΗΝ ΔΙΑΡΚΕΙΑ
ΤΗΣ ΕΓΚΑΤΑΣΤΑΣΗΣ. ΤΑ ΕΝΔΟΔΑΠΕΔΙΑ ΚΟΥΤΙΑ
ΠΡΟΜΗΘΕΥΟΝΤΑΙ ΜΕ ΤΟΝ ΗΛΕΚΤΡΟΛΟΓΙΚΟ ΕΞΟΠΛΙΣΜΟ.
2. WIRELESS ACCESS POINTS WILL BE ROOF MOUNTED AT
3600mm AFF IN CARGO BAY ROOM 140. SEE SHEET T-504, DETAIL A3.
ΤΑ ΑΣΥΡΜΑΤΑ ΣΗΜΕΙΑ ΠΡΟΣΒΑΣΗΣ ΘΑ ΕΙΝΑΙ
ΤΟΠΟΘΕΤΗΜΕΝΑ ΣΤΗΝ ΟΡΟΦΗ ΣΤΑ 3600 MM AFF ΣΤΟΝ
ΜΕΤΑΦΟΡΙΚΟ ΣΤΑΘΜΟ ΕΜΠΟΡΕΥΜΑΤΩΝ ΧΩΡΟ 140. ΔΕΣ
ΣΧΕΔΙΟ Τ-504, ΛΕΠΤΟΜΕΡΕΙΑ Α3.
3. ROUTE 25mm CONDUIT FROM FLOOR BOX TO ADJACENT
WALL AND EXTEND CONDUIT UP INSIDE THE WALL AND
ROUTE TO NEAREST TELECOM CABLE TRAY.
ΧΡΗΣΙΜΟΠΟΙΗΣΤΕ ΣΩΛΗΝΑ ΚΑΛΩΔΙΩΝ 25mm ΑΠΟ ΤΟ
ΕΠΙΔΑΠΕΔΙΟ ΚΟΥΤΙ ΠΡΟΣ ΤΟΝ ΔΙΠΛΑΝΟ ΤΟΙΧΟ ΚΑΙ
ΕΠΕΚΤΕΙΝΕΤΑΙ ΠΡΟΣ ΤΑ ΠΑΝΩ ΕΝΤΟΣ ΤΟΥ ΤΟΙΧΟΥ ΕΩΣ ΤΗΝ
ΠΛΗΣΙΕΣΤΕΡΗ ΣΧΑΡΑ ΤΗΛΕΠΙΚΟΙΝΩΝΙΑΚΩΝ ΚΑΛΩΔΙΩΝ
4. TWO (2) 100mm CONDUITS TO ROOF CABLE TRANSITION
ENCLOSURE. SEE SHEET T-130 AND DETAIL ON T-507,
DETAIL C1.
ΔΥΟ (2) 100mm ΣΩΛΗΝΕΣ ΠΡΟΣ TO ΠΕΡΙΒΛΗΜΑ ΜΕΤΑΒΑΣΗΣ
ΚΑΛΩΔΙΩΝ ΣΤΗΝ ΟΡΟΦΗ. ΒΛΕΠΕ ΣΧΕΔΙΟ Τ-130 ΚΑΙ
ΛΕΠΤΟΜΕΡΕΙΑ C1 ΣΤΟ ΣΧΕΔΙΟ Τ-507
A. SEE T-001 & T-002 FOR LEGEND, ABBREVIATIONS AND
GENERAL NOTES.
ΒΛΕΠΕ Τ-001 & Τ-002 ΓΙΑ ΥΠΟΜΝΗΜΑ, ΣΥΝΤΜΗΣΕΙΣ
ΚΑΙ ΓΕΝΙΚΕΣ ΠΑΡΑΤΗΡΗΣΕΙΣ.
B. SEE SHEET T-002 FOR TELECOMMUNICATION DEVICE
MOUNTING HEIGHTS UNLESS OTHERWISE NOTED.
ΒΛΕΠΕ ΣΧΕΔΙΟ Τ-002 ΓΙΑ ΥΨΗ ΤΟΠΟΘΕΤΗΣΗΣ
ΤΗΛΕΠΙΚΟΙΝΩΝΙΑΚΩΝ ΣΥΣΚΕΥΩΝ ΕΚΤΟΣ ΑΝ ΑΝΑΓΡΑΦΕΤΑΙ
ΔΙΑΦΟΡΕΤΙΚΑ
C. PROVIDE 300-MILLIMETER WIDE BY 100-MILLIMETER HIGH
SLOTTED BOTTOM WIRE BASKET CABLE TRAY FOR
TELECOMMUNICATIONS HORIZONTAL CABLING. SEE SHEET
T-505, DETAIL C1 FOR TRAY INSTALLATION (TYP).
ΠΡΟΜΗΘΕΥΣΤΕ ΣΧΑΡΑ ΚΑΛΩΔΙΩΝ ΣΥΡΜΑΤΙΝΟΥ ΠΛΕΓΜΑΤΟΣ
ΜΕ ΔΙΑΤΡΗΤΟ ΚΑΤΩ ΜΕΡΟΣ, ΠΛΑΤΟΥΣ 300mm x 100mm
ΥΨΟΥΣ ΓΙΑ ΤΗΝ ΟΡΙΖΟΝΤΙΑ ΚΑΛΩΔΙΩΣΗ ΤΗΛΕΠΙΚΟΙΝΩΝΙΩΝ.
ΒΛΕΠΕ ΣΧΕΔΙΟ Τ-505, ΛΕΠΤΟΜΕΡΕΙΑ C1 ΓΙΑ ΤΟΠΟΘΕΤΗΣΗ
ΣΧΑΡΑΣ (ΤΥΡ)
D. COORDINATE CATEGORY 6 CABLING ENTRY POINT INTO
MODULAR FURNITURE WITH FURNITURE INSTALLER PRIOR TO
CABLING INSTALLATION.
ΣΥΝΤΟΝΙΣΤΕ ΤΟ ΣΗΜΕΙΟ ΕΙΣΟΔΟΥ ΤΗΣ ΚΑΤΗΓΟΡΙΑΣ 6
ΚΑΛΩΔΙΩΣΗΣ ΣΤΗΝ ΣΥΝΑΡΜΟΛΟΓΟΥΜΕΝΗ ΕΠΙΠΛΩΣΗ, ΜΕ ΤΟΝ
ΕΓΚΑΤΑΣΤΑΤΗ ΕΠΙΠΛΩΣΗΣ ΠΡΙΝ ΑΠΟ ΤΗΝ ΕΓΚΑΤΑΣΤΑΣΗ
ΤΗΣ ΚΑΛΩΔΙΩΣΗΣ.
APPROVED BY: PAM COWDEN, P.E.
SP
P
SPSP
S P
S P
M A
T C
H L
IN
E
S E
E S
H E
E T
T -1
Γ Ρ
Α Μ
Μ Η
Σ Υ
Ν Α
Ρ Μ
Ο Γ Η
Σ Β
Λ Ε
Π Ε
Σ Χ
Ε Δ
ΙΟ
T
-1
MATCHLINE SEE SHEET T-117
ΓΡΑΜΜΗ ΣΥΝΑΡΜΟΓΗΣ ΒΛΕΠΕ
ΣΧΕΔΙΟ T-117
1 2 4 5.1
CE
CF
CG
CH
CARGO BAY
AP AP
AP AP
AP
AP
300mm x 100mm
H = 3095mmCT
300mm x 100mm
H = 3095mmCT
300mm x 100mm
H = 3095mmCT
300mm x 100mm
H = 3095mmCT
SM
F
1 5 8 14 16
CA
CB
CE
CH
CG
B
C
K
G
D
C
B
1 2 3 4 5
1568016
DWG
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.
SCALE:
N62470-23-C-XXXX
RICHARD L STEPHENS, P.E.
LMM/MWL
CHIEF ENG/ARCH
DES DRW CHK
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
S O
U D
A B
A Y
SHEET KEYED NOTES:
ΠΑΡΑΤΗΡΗΣΕΙΣ ΣΧΕΔΙΟΥ:
GENERAL NOTES:
ΓΕΝΙΚΕΣ ΠΑΡΑΤΗΡΗΣΕΙΣ:
A KEYPLAN:
ΣΧΕΔΙΟ ΚΛΕΙΔΙ:
DRAWFORM REVISION: 25 AUGUST 2020
1 2 3 4 5
D
C
B
A
UNCLASSIFIED
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
A T
L A
N T
IC
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
N O
R F
O L K
V
A L A
N T
C A
P
IT
A L I M
P R
O V
E M
E N
T S
BRANCH MANAGER
PM/DM
SATISFACTORY TO DATE
FIRE PROTECTION DPS (DOUG STULTZ)
SEK (SOLVEIGH KEENE)
1 : 100
/3
/2
:2 :3
A
M
C R e v it L o c a l_ M o d e ls \2
\P
-1
-T R d ia n e .r io s E
Z M
N
.r v t
03/31/2023
T-116
MA DR JH
P J
O
IN
T M
O B
IL
IT
Y P
R O
C E
S S
IN
G
F A
C
IL
IT
Y
S O
U D
A B
A Y
G
R E
E C
E
F L
O O
R P
A N
L E
V E
L
S
E C
T O
R F
T
E L E
C O
M
14068913
T -1
Κ Α
Τ Ο
Ψ Η
Ε
Π
ΙΠ
Ε Δ
Ο
Τ Ο
Μ Ε
Α Σ
F
Τ Η
Λ Ε
Π
ΙΚ
Ο
ΙΝ
Ω Ν
ΙΕ
Σ
SCALE: 1 : 100
FLOOR PLAN - LEVEL 1 - SECTOR F - TELECOM
ΚΑΤΟΨΗ - ΕΠΙΠΕΔΟ 1 - ΤΟΜΕΑΣ F - ΤΗΛΕΠΙΚΟΙΝΩΝΙΕΣ 0 5000 10000
MILLIMETRESSCALE 1:100
30001000
PLAN NORTH
ΚΑΤΟΨΗ ΒΟΡΡΑ
A. SEE T-001 & T-002 FOR LEGEND, ABBREVIATIONS AND
GENERAL NOTES.
ΒΛΕΠΕ Τ-001 & Τ-002 ΓΙΑ ΥΠΟΜΝΗΜΑ, ΣΥΝΤΜΗΣΕΙΣ
ΚΑΙ ΓΕΝΙΚΕΣ ΠΑΡΑΤΗΡΗΣΕΙΣ
B. SEE SHEET T-002 FOR TELECOMMUNICATION DEVICE
MOUNTING HEIGHTS UNLESS OTHERWISE NOTED.
ΒΛΕΠΕ ΣΧΕΔΙΟ Τ-002 ΓΙΑ ΥΨΗ ΤΟΠΟΘΕΤΗΣΗΣ
ΤΗΛΕΠΙΚΟΙΝΩΝΙΑΚΩΝ ΣΥΣΚΕΥΩΝ ΕΚΤΟΣ ΑΝ ΑΝΑΓΡΑΦΕΤΑΙ
ΔΙΑΦΟΡΕΤΙΚΑ
C. PROVIDE 300-MILLIMETER WIDE BY 100-MILLIMETER HIGH
SLOTTED BOTTOM WIRE BASKET CABLE TRAY FOR
TELECOMMUNICATIONS HORIZONTAL CABLING. SEE SHEET
T-505, DETAIL C1 FOR TRAY INSTALLATION (TYP).
ΠΡΟΜΗΘΕΥΣΤΕ ΣΧΑΡΑ ΚΑΛΩΔΙΩΝ ΣΥΡΜΑΤΙΝΟΥ ΠΛΕΓΜΑΤΟΣ
ΜΕ ΔΙΑΤΡΗΤΟ ΚΑΤΩ ΜΕΡΟΣ, ΠΛΑΤΟΥΣ…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .