Attachment H - dwg12of24.pdf

PDF 8 MB Posted

Attached to
P903 Joint Mobility Processing Center at NSA Souda Bay, Greece
Solicitation number
N6247023R0005
Issued by

View the file

Other files

File Type Posted
N6247023R0005 Amend 0004.pdf PDF
N6247023R0005 Amend 0003.pdf PDF
N6247023R0005 Amend 0002.pdf PDF
Attachment K - Pre-proposal Conference Attendee Log.pdf PDF
N6247023R0005 Amend 0001.pdf PDF
Attachment H - dwg20of24.pdf PDF
Attachment F - LRA Commercial Vehicle Inspection Procedures.pdf PDF
Attachment H - dwg10of24.pdf PDF
Attachment H - dwg4of24.pdf PDF
Attachment B - SEC-NAV_5512_1_11787 Form.pdf PDF
Attachment A - Pre-Proposal Inquiry Form.xls XLS spreadsheet
Attachment H - dwg23of24.pdf PDF
Attachment H - dwg6of24.pdf PDF
Attachment H - dwg18of24.pdf PDF
Attachment C - Construction Experience Project Data Sheet.pdf PDF
Attachment I - DWG INDEX.pdf PDF
Attachment G - Specifications 1of3.pdf PDF
Attachment H - dwg1of24.pdf PDF
Attachment H - dwg2of24.pdf PDF
Attachment H - dwg9of24.pdf PDF
Attachment H - dwg16of24.pdf PDF
Attachment H - dwg3of24.pdf PDF
Attachment D - Past Performance Questionnaire (PPQ).pdf PDF
Attachment H - dwg11of24.pdf PDF
Attachment E - Schedule B Price Proposal Form.pdf PDF
Attachment H - dwg15of24.pdf PDF
Attachment H - dwg8of24.pdf PDF
Attachment H - dwg21of24.pdf PDF
Attachment J - Base Access Form.pdf PDF
Attachment H - dwg5of24.pdf PDF
Attachment H - dwg7of24.pdf PDF
Attachment H - dwg17of24.pdf PDF
Attachment H - dwg19of24.pdf PDF
Attachment G - Specifications 2of3.pdf PDF
Attachment G - Specifications 3of3.pdf PDF
Attachment H - dwg24of24.pdf PDF
Attachment H - dwg14of24.pdf PDF
Attachment H - dwg13of24.pdf PDF
Attachment H - dwg22of24.pdf PDF
N6247023R0005.pdf PDF
Show all 40

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FACP FIRE ALARM CONTROL PANEL-

*UFC 4-440-01, WAREHOUSE AND STORAGE FACILITIES (CHANGE 1, 01 APRIL 2019).

*UFC 4-440-01, ΑΠΟΘΗΚΕΣ ΚΑΙ ΕΓΚΑΤΑΣΤΑΣΕΙΣ ΑΠΟΘΗΚΕΥΣΗΣ (ΑΛΛΑΓΗ 1, 01 ΑΠΡIΛΙΟΣ 2019).

*UFC 3-600-01, FIRE PREVENTION ENGINEERING FOR FACILITIES (CHANGE 6, 06 MAY 2021).

*UFC 3-600-01, ΜΗΧΑΝΙΚΗ ΠΡΟΛΗΨΗ ΠΥΡΚΑΓΙΑΣ ΣΕ ΕΓΚΑΤΑΣΤΑΣΕΙΣ (ΑΛΛΑΓΗ 6, 06 ΜAΙΟΣ 2021).

*NFPA 415 - 2022 EDITION, AIRCRAFT TERMINAL BUILDINGS. FUELING RAMP DRAINAGE, AND LOADING WALKWAYS.

*NFPA 415 - ΕΚΔΟΣΗ 2022, ΤΕΡΜΑΤΙΚΟΙ ΣΤΑΘΜΟΙ ΑΕΡΟΣΚΑΦΩΝ. ΑΠΟΧΕΤΕΥΣΗ ΡΑΜΠΑΣ ΤΡΟΦΟΔΟΣΙΑΣ ΚΑΥΣΙΜΩΝ, ΚΑΙ ΔΙΑΔΡΟΜΩΝ ΦΟΡΤΩΣΗΣ.

*NFPA 291 - 2022 EDITION, RECOMMENDED PRACTICE FOR FIRE HYDRANT TESTING AND MARKING OF HYDRANTS.

*NFPA 291 - ΕΚΔΟΣΗ 2022, ΣΥΝΙΣΤΩΜΕΝΗ ΠΡΑΚΤΙΚΗ ΓΙΑ ΤΗ ΔΟΚΙΜΗ ΚΑΙ ΤΗΝ ΣΗΜΑΝΣΗ ΤΩΝ ΠΥΡΟΣΒΕΣΤΙΚΩΝ ΚΡΟΥΝΩΝ

*NFPA 101 - 2021 EDITION, LIFE SAFETY CODE.

*NFPA 101 - ΕΚΔΟΣΗ 2021, ΚΩΔΙΚΑΣ ΠΑΘΗΤΙΚΗΣ ΠΥΡΟΠΡΟΣΤΑΣΙΑΣ

*NFPA 72 - 2022 EDITION, NATIONAL FIRE ALARM AND SIGNALING CODE.

*NFPA 72 - ΕΚΔΟΣΗ 2022, ΑΜΕΡΙΚΑΝΙΚΟΣ ΚΩΔΙΚΑΣ ΣΥΝΑΓΕΡΜΟΥ ΠΥΡΚΑΓΙΑΣ ΚΑΙ ΣΗΜΑΝΣΗΣ.

*NFPA 25 - 2023 EDITION, STANDARD FOR THE INSPECTION, TESTING, AND MAINTENANCE OF WATER-BASED FIRE PROTECTION SYSTEMS.

*NFPA 25 - ΕΚΔΟΣΗ 2023, ΠΡΟΤΥΠΟ ΓΙΑ ΤΗΝ ΕΠΙΘΕΩΡΗΣΗ, ΤΗΝ ΔΟΚΙΜΗ ΚΑΙ ΤΗΝ ΣΥΝΤΗΡΗΣΗ ΤΩΝ ΣΥΣΤΗΜΑΤΩΝ ΠΥΡΟΠΡΟΣΤΑΣΙΑΣ ΜΕ ΒΑΣΗ ΤΟ ΝΕΡΟ.

*NFPA 24 - 2022 EDITION, STANDARD FOR THE INSTALLATION OF PRIVATE FIRE SERVICE MAINS AND THEIR APPURTENANCES *NFPA 24 - ΕΚΔΟΣΗ 2022, ΠΡΟΤΥΠΟ ΓΙΑ ΤΗΝ ΕΓΚΑΤΑΣΤΑΣΗ ΤΩΝ ΙΔΙΩΤΙΚΩΝ ΚΕΝΤΡΙΚΩΝ ΣΩΛΗΝΩΣΕΩΝ ΠΥΡΟΣΒΕΣΗΣ ΚΑΙ ΤΑ ΠΛΕΟΝΕΚΤΗΜΑΤΑ ΤΟΥΣ.

*NFPA 14 - 2019 EDITION, STANDARD FOR THE INSTALLATION OF STANDPIPES AND HOSE SYSTEMS.

*NFPA 14 - ΕΚΔΟΣΗ 2019, ΠΡΟΤΥΠΟ ΓΙΑ ΤΗΝ ΕΓΚΑΤΑΣΤΑΣΗ ΣΩΛΗΝΩΣΕΩΝ ΣΤΑΘΕΡΗΣ ΠΙΕΣΗΣ ΚΑΙ ΣΥΣΤΗΜΑΤΩΝ ΠΥΡΟΣΒΕΣΤΙΚΩΝ ΚΡΟΥΝΩΝ.

*NFPA 13 - 2022 EDITION, STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS.

*NFPA 13 - ΕΚΔΟΣΗ 2022, ΠΡΟΤΥΠΟ ΓΙΑ ΤΗΝ ΕΓΚΑΤΑΣΤΑΣΗ ΣΥΣΤΗΜΑΤΩΝ ΚΑΤΑΙΟΝΗΤΗΡΩΝ.

*NFPA 10 - 2022 EDITION, STANDARD FOR PORTABLE FIRE EXTINGUISHERS.

*NFPA 10 - ΕΚΔΟΣΗ 2022, ΠΡΟΤΥΠΟ ΓΙΑ ΦΟΡΗΤΟΥΣ ΠΥΡΟΣΒΕΣΤΗΡΕΣ.

THE FOLLOWING CODES AND STANDARDS APPLY:

ΟΙ ΑΚΟΛΟΥΘΟΙ ΚΩΔΙΚΕΣ ΚΑΙ ΠΡΟΤΥΠΑ ΕΦΑΡΜΟΖΟΝΤΑΙ:

Ø

IN ACCORDANCE WITHIAW

HIGH VOLUME LOW SPEEDHVLS -

WELD WIRE FABRIC-WWF

POST INDICATING VALVEPIV -

MECHANICAL JOINTMJ -

MH - MANHOLE

FLANGEFLG

FIRE HYDRANTFH

FIRE DEPARTMENT CONNECTION

-FDC

DIVISIONDIV -

SP

BOT BOTTOM

EACH

DIAMETER

DETAIL

EA

DIA

DN DOWN

-DET

AFF ABOVE FINISHED FLOOR-

ADJ ADJUSTABLE-

ALT ALTERNATE-

APPROX APPROXIMATE-

ARCH ARCHITECTURAL-

BLDG BUILDING-

CMU CONCRETE MASONRY UNIT-

CLG

CL

CEILING-

CENTERLINE-

CONN CONNECTION/CONNECT-

CORR CORRIDOR-

MINIMUM

SHT

REQD

RPM

SHEET

REQUIRED

REVOLUTIONS PER MINUTE-

RAD

PRESS

NTS

OD

OC

NOM

NPT

MISC

MTG

MTD

MFR

PHASE

PRESSURE

RADIUS-

ON CENTER

NATIONAL PIPE THREAD

NOT TO SCALE

OUTSIDE DIAMETER-

NOMINAL-

-TYP TYPICAL

MOUNTING

MANUFACTURER

MOUNTED

MISCELLANEOUS

-NO

MIN

NUMBER

DIM DIMENSION-

DWG DRAWING-

EQUIP EQUIPMENT-

TEMP

SQ

TEMPERATURE-

- SQUARE

SPRINKLER-

-UNO UNLESS NOTED OTHERWISE

-VOL VOLUME

-W/ WITH

-W/O WITHOUT

-LTG LIGHTING

GA

GALV

FTG

GALVANIZED

FOOTING

GAUGE

FLR FLOOR

SPEC - SPECIFICATION

ELEV ELEVATION-

MAX MAXIMUM-

CODES AND STANDARDS

ΚΩΔΙΚΟΙ ΚΑΙ ΠΡΟΤΥΠΑ

GENERAL NOTES:

ΓΕΝΙΚΕΣ ΣΗΜΕΙΩΣΕΙΣ:

ABBREVIATIONS

ΣΥΝΤΟΜΟΓΡΑΦΙΕΣ

1. FIRE SUPPRESSION DRAWINGS SHOW A DIAGRAMMATIC SYSTEM TO INCORPORATE MAJOR ELEMENTS FOR THE CONDITIONAL APPROVAL PRIOR TO THE FINAL DESIGN AND SUBMISSION PROVIDED BY THE CONTRACTOR. THE CONTRACTOR IS RESPONSIBLE FOR THE FINAL LAYOUT, DESIGN, CALCULATIONS. THE CONTRACTOR MUST SUBMIT HIS DESIGN, CALCULATIONS AND EQUIPMENT TO THE GOVERNMENT FOR APPROVAL.

ΤΑ ΣΧΕΔΙΑ ΠΑΘΗΤΙΚΗΣ ΠΥΡΟΠΡΟΣΤΑΣΙΑΣ ΠΑΡΟΥΣΙΑΖΟΥΝ ΤΟ ΣΥΣΤΗΜΑ ΔΙΑΓΡΑΜΜΑΤΙΚΑ ΜΕ ΣΚΟΠΟ ΝΑ ΕΝΣΩΜΑΤΩΘΟΥΝ ΤΑ ΚΥΡΙΑ ΣΤΟΙΧΕΙΑ ΓΙΑ ΤΗΝ ΑΠΟΔΟΧΗ ΥΠΟ ΠΡΟΫΠΟΘΕΣΕΙΣ ΠΡΙΝ ΑΠΟ ΤΟΝ ΤΕΛΙΚΟ ΣΧΕΔΙΑΣΜΟ ΚΑΙ ΥΠΟΒΟΛΗ ΠΟΥ ΘΑ ΠΡΟΜΗΘΕΥΤΕΙ ΑΠΟ ΤΟΝ ΕΡΓΟΛΑΒΟ. Ο ΕΡΓΟΛΑΒΟΣ ΕΙΝΑΙ ΥΠΕΥΘΥΝΟΣ ΓΙΑ ΤΗΝ ΤΕΛΙΚΗ ΔΙΑΤΑΞΗ, ΣΧΕΔΙΑΣΜΟ, ΥΠΟΛΟΓΙΣΜΟΥΣ. Ο ΕΡΓΟΛΑΒΟΣ ΠΡΕΠΕΙ ΝΑ ΥΠΟΒΑΛΕΙ ΤΟΝ ΣΧΕΔΙΑΣΜΟ ΤΟΥ, ΥΠΟΛΟΓΙΣΜΟΥΣ ΚΑΙ ΕΞΟΠΛΙΣΜΟ ΠΡΟΣ ΤΗΝ ΚΥΒΕΡΝΗΣΗ ΓΙΑ

ΑΠΟΔΟΧΗ.

2. DO NOT SCALE DRAWINGS TO DETERMINE DIMENSIONS.

ΜΗΝ ΧΡΗΣΙΜΟΠΟΙΕΙΤΕ ΤΗΝ ΚΛΙΜΑΚΑ ΤΩΝ ΣΧΕΔΙΩΝ ΓΙΑ ΝΑ ΠΡΟΣΔΙΟΡΙΣΕΤΕ ΔΙΑΣΤΑΣΕΙΣ.

3. DRAWINGS INDICATE DESIGN INTENT AND GENERAL ROUTING OF FIRE SPRINKLER PIPING. PROVIDE ADDITIONAL OFFSETS, FITTINGS, AND ADDITIONAL SPRINKLER HEADS TO MEET CODE REQUIREMENTS, ETC, TO COORDINATE PIPING LAYOUT WITH STRUCTURAL, DUCTWORK, PIPING, CONDUIT, ETC.

ΤΑ ΣΧΕΔΙΑ ΠΑΡΟΥΣΙΑΖΟΥΝ ΤΗΝ ΠΡΟΘΕΣΗ ΣΧΕΔΙΑΣΜΟΥ ΚΑΙ ΓΕΝΙΚΗ ΟΔΕΥΣΗ ΤΩΝ ΣΩΛΗΝΩΣΕΩΝ ΚΑΤΑΙΟΝΙΣΜΟΥ. ΠΡΟΜΗΘΕΥΣΤΕ ΠΡΟΣΘΕΤΕΣ ΜΕΤΑΤΟΠΙΣΕΙΣ, ΕΞΑΡΤΗΜΑΤΑ, ΚΑΙ ΚΕΦΑΛΕΣ ΩΣΤΕ ΝΑ ΠΛΗΡΟΥΝΤΑΙ ΟΙ ΑΠΑΙΤΗΣΕΙΣ ΤΩΝ ΚΑΝΟΝΙΣΜΩΝ, ΚΛΠ. ΚΑΙ ΝΑ ΣΥΝΤΟΝΙΣΤΕΙ Η ΔΙΑΤΑΞΗ ΣΩΛΗΝΩΣΕΩΝ ΜΕ ΤΑ ΣΤΑΤΙΚΑ, ΑΕΡΑΓΩΓΟΥΣ, ΣΩΛΗΝΩΣΕΙΣ, ΑΓΩΓΟΥΣ, ΚΛΠ.

4. COORDINATE WITH OTHER TRADES, VERIFY DIMENSIONS, CONDITIONS AND LAYOUT AT JOB SITE PRIOR TO FABRICATION OF MATERIAL AND PROVIDE ADDITIONAL MATERIAL OR MODIFICATIONS TO FURNISH A COMPLETE AND OPERABLE SPRINKLER SYSTEM TO MEET THE REQUIRED CODES.

ΣΥΝΤΟΝΙΣΤΕ ΜΕ ΤΙΣ ΑΛΛΕΣ ΕΙΔΙΚΟΤΗΤΕΣ, ΕΠΑΛΗΘΕΥΣΤΕ ΔΙΑΣΤΑΣΕΙΣ, ΣΥΝΘΗΚΕΣ ΚΑΙ ΔΙΑΤΑΞΗ ΕΠΙ ΤΟΠΟΥ ΣΤΟ ΕΡΓΟ ΠΡΙΝ ΤΗΝ ΚΑΤΑΣΚΕΥΗ ΤΩΝ ΥΛΙΚΩΝ ΚΑΙ ΠΡΟΜΗΘΕΥΣΤΕ ΠΡΟΣΘΕΤΑ ΥΛΙΚΑ Η ΤΡΟΠΟΠΟΙΗΣΕΙΣ ΩΣΤΕ ΝΑ ΠΡΟΜΗΘΕΥΣΕΤΕ ΕΝΑ ΠΛΗΡΕΣ ΚΑΙ ΛΕΙΤΟΥΡΓΙΚΟ ΣΥΣΤΗΜΑ ΚΑΤΑΙΟΝΙΣΜΟΥ ΠΟΥ ΘΑ ΠΛΗΡΕΙ ΤΙΣ

ΑΠΑΙΤΗΣΕΙΣ ΤΩΝ ΚΑΝΟΝΙΣΜΩΝ.

5. SPRINKLER PIPING MUST BE SIZED USING HYDRAULIC CALCULATIONS. DENSITY AND AREA OF APPLICATION MUST BE PER FIRE PROTECTION REQUIREMENTS TABLE

ON DRAWING F-002. SPRINKLER SYSTEM VELOCITY MUST NOT EXCEED 20 FEET PER SECOND.

Η ΣΩΛΗΝΩΣΕΙΣ ΚΑΤΑΙΟΝΙΣΜΟΥ ΘΑ ΠΡΕΠΕΙ ΝΑ ΔΙΑΣΤΑΣΙΟΛΟΓΗΘΟΥΝ ΕΦΑΡΜΟΖΟΝΤΑΣ ΥΔΡΑΥΛΙΚΟΥΣ ΥΠΟΛΟΓΙΣΜΟΥΣ. Η ΠΥΚΝΟΤΗΤΑ ΚΑΙ Η ΕΠΙΦΑΝΕΙΑ ΤΗΣ ΕΦΑΡΜΟΓΗΣ ΠΡΕΠΕΙ ΝΑ ΕΙΝΑΙ ΣΥΜΦΩΝΗ ΜΕ ΤΟΝ ΠΙΝΑΚΑ ΑΠΑΙΤΗΣΕΩΝ ΠΥΡΑΣΦΑΛΕΙΑΣ ΣΤΟ ΣΧΕΔΙΟ F-002. Η ΤΑΧΥΤΗΤΑ ΤΟΥ ΣΥΣΤΗΜΑΤΟΣ ΚΑΤΑΙΟΝΙΣΜΟΥ ΔΕΝ ΠΡΕΠΕΙ ΝΑ

ΥΠΕΡΒΑΙΝΕΙ ΤΑ 20 ΠΟΔΙΑ ΑΝΑ ΔΕΥΤΕΡΟΛΕΠΤΟ (6.09 ΜΕΤΡΑ ΑΝΑ ΔΕΥΤΕΡΟΛΕΠΤΟ)

6. ADHERE TO AND OBTAIN PERMITS, LICENSES AND GOVERNMENT REQUIREMENTS.

ΤΗΡΕΙΤΕ ΚΑΙ ΠΡΟΜΗΘΕΥΤΕΙΤΕ ΑΔΕΙΕΣ, ΠΙΣΤΟΠΟΙΗΤΙΚΑ ΚΑΙ ΚΥΒΕΡΝΗΤΙΚΕΣ ΑΠΑΙΤΗΣΕΙΣ.

7. FIRE STOP PENETRATIONS OF SMOKE/FIRE WALLS. FIRE STOPPING MUST BE OF A U.L. LISTED AND/OR FM APPROVED ASSEMBLY.

ΕΦΑΡΜΟΣΤΕ ΠΥΡΟΦΡΑΓΜΟΥΣ ΣΕ ΔΙΑΤΡΗΣΕΙΣ ΣΕ ΤΟΙΧΟΥΣ ΜΕ ΔΕΙΚΤΗ ΠΥΡΑΝΤΙΣΤΑΣΗΣ Η ΠΡΟΣΤΑΣΙΑΣ ΑΠΟ ΚΑΠΝΟ. ΟΙ ΠΥΡΟΦΡΑΓΜΟΙ ΘΑ ΠΡΕΠΕΙ ΝΑ ΕΙΝΑΙ

ΚΑΤΑΧΩΡΗΜΕΝΟΙ ΚΑΙ ΕΓΚΕΚΡΙΜΕΝΟΙ ΚΑΤΑ U.L. Η/ΚΑΙ ΣΥΣΤΗΜΑ ΕΓΚΕΚΡΙΜΕΝΟ ΚΑΤΑ FM.

8. HANGER LOCATIONS SHOWN ARE DIAGRAMMATIC. MEANS OF HANGING AND HANGER SPACING MUST BE PER NFPA 13, AND COORDINATE WITH BUILDING

STRUCTURE.

ΟΙ ΘΕΣΕΙΣ ΑΝΑΡΤΗΣΕΩΝ ΠΟΥ ΠΑΡΟΥΣΙΑΖΟΝΤΑΙ ΕΙΝΑΙ ΔΙΑΓΡΑΜΜΑΤΙΚΕΣ. Ο ΤΡΟΠΟΣ ΑΝΑΡΤΗΣΗΣ ΚΑΙ ΟΙ ΑΠΟΣΤΑΣΕΙΣ ΜΕΤΑΞΥ ΤΩΝ ΑΝΑΡΤΗΣΕΩΝ ΠΡΕΠΕΙ ΝΑ ΕΙΝΑΙ ΣΥΜΦΩΝΑ ΜΕ ΤΟΝ ΚΑΝΟΝΙΣΜΟ NFPA 13, ΚΑΙ ΣΕ ΣΥΝΤΟΝΙΣΜΟ ΜΕ ΤΗΝ ΚΑΤΑΣΚΕΥΗ ΤΟΥ ΚΤΙΡΙΟΥ.

9. CONTROL VALVES AND FLOW SWITCHES FOR THE FIRE SPRINKLER SYSTEM MUST BE ELECTRONICALLY SUPERVISED AND MONITORED BY BASE FIRE DEPARTMENT.

FLOW SWITCHES & TAMPER SWITCHES MUST BE FURNISHED AND PROVIDED BY DIV. 21. WIRING TO FIRE ALARM SYSTEM MUST BE TERMINATED AND TESTED BY DIV.

28.

ΒΑΝΕΣ ΕΛΕΓΧΟΥ ΚΑΙ ΔΙΑΚΟΠΤΕΣ ΡΟΗΣ ΓΙΑ ΤΟ ΣΥΣΤΗΜΑ ΚΑΤΑΙΟΝΙΣΜΟΥ ΠΡΕΠΕΙ ΝΑ ΕΧΟΥΝ ΗΛΕΚΡΟΝΙΚΗ ΕΠΙΘΕΩΡΗΣΗ ΚΑΙ ΝΑ ΠΑΡΑΚΟΛΟΥΘΟΥΝΤΑΙ ΑΠΟ ΤΗΝ ΠΥΡΟΣΒΕΣΤΙΚΗ ΥΠΗΡΕΣΙΑ ΤΗΣ ΒΑΣΗΣ. ΟΙ ΔΙΑΚΟΠΤΕΣ ΡΟΗΣ ΚΑΙ ΔΙΑΚΟΠΤΕΣ ΘΕΣΕΩΣ (ΕΝΕΡΓΕΙΑΣ ΣΤΗΝ ΒΑΝΑ) ΠΡΕΠΕΙ ΝΑ ΔΙΑΤΕΘΟΥΝ ΚΑΙ ΝΑ ΠΡΟΜΗΘΕΥΤΟΥΝ ΑΠΟ ΤΟ DIV. 21. Η ΚΑΛΩΔΙΩΣΗ ΣΤΟ ΣΥΣΤΗΜΑ ΣΥΝΑΓΕΡΜΟΥ ΠΡΕΠΕΙ ΝΑ ΤΕΡΜΑΤΙΣΤΕΙ ΚΑΙ ΝΑ ΔΟΚΙΜΑΣΤΕΙ ΑΠΟ ΤΟ DIV. 28.

10. CONTROL, DRAIN AND TEST CONNECTION VALVES MUST BE PROVIDED WITH PERMANENTLY MARKED WEATHERPROOF METAL OR PLASTIC IDENTIFICATION SIGNS.

THE SIGN MUST BE SECURED WITH CORROSION-RESISTANT WIRE, CHAIN, OR OTHER APPROVED MEANS.

ΟΙ ΒΑΝΕΣ ΕΛΕΓΧΟΥ, ΑΠΟΡΡΟΗΣ ΚΑΙ ΕΛΕΓΧΟΥ ΣΥΝΔΕΣΗΣ ΠΡΕΠΕΙ ΝΑ ΠΡΟΜΗΘΕΥΟΝΤΑΙ ΜΕ ΜΕΤΑΛΛΙΚΕΣ Η ΠΛΑΣΤΙΚΕΣ ΠΙΝΑΚΙΔΕΣ ΜΟΝΙΜΗΣ ΣΗΜΑΝΣΗΣ ΑΝΘΕΚΤΙΚΗΣ ΣΤΙΣ ΚΑΙΡΙΚΕΣ ΣΥΝΘΗΚΕΣ. Η ΠΙΝΑΚΙΔΑ ΠΡΕΠΕΙ ΝΑ ΑΣΦΑΛΙΖΕΤΑΙ ΜΕ ΣΥΡΜΑ, ΑΛΥΣΙΔΑ Η ΑΛΛΟ ΑΠΟΔΕΚΤΟ ΜΕΣΟ ΑΝΤΙΣΚΩΡΙΑΚΟΥ ΤΥΠΟΥ.

11. DESIGN AND LAYOUT OF SPRINKLER SYSTEM MUST BE IN ACCORDANCE WITH REQUIREMENTS OF SPECIFICATION 21 13 13 WET PIPE SPRINKLER SYSTEMS. SUBMIT COMPLETE SHOP DRAWINGS, MATERIAL DATA, HYDRAULIC CALCULATIONS, AND FLOW TEST RESULTS TO CONTRACTING OFFICER FOR REVIEW AND APPROVAL

PRIOR TO COMMENCING FABRICATION AND WORK.

Ο ΣΧΕΔΙΑΣΜΟΣ ΚΑΙ Η ΔΙΑΤΑΞΗ ΤΟΥ ΣΥΣΤΗΜΑΤΟΣ ΚΑΤΑΙΟΝΙΣΜΟΥ ΠΡΕΠΕΙ ΝΑ ΕΙΝΑΙ ΣΥΜΦΩΝΟ ΜΕ ΤΙΣ ΑΠΑΙΤΗΣΕΙΣ ΤΗΣ ΠΡΟΔΙΑΓΡΑΦΗΣ 21 13 13 WET PIPE SPRINKLER SYSTEMS (ΣΥΣΤΗΜΑΤΑ ΚΑΤΑΙΟΝΙΣΜΟΥ ΝΕΡΟΥ ΥΠΟ ΠΙΕΣΗ). ΥΠΟΒΑΛΕΤΕ ΠΛΗΡΗ ΚΑΤΑΣΚΕΥΑΣΤΙΚΑ ΣΧΕΔΙΑ, ΧΑΡΑΚΤΗΡΙΣΤΙΚΑ ΥΛΙΚΩΝ, ΥΔΡΑΥΛΙΚΟΥΣ ΥΠΟΛΟΓΙΣΜΟΥΣ, ΚΑΙ ΑΠΟΤΕΛΕΣΜΑΤΑ ΥΔΡΑΥΛΙΚΩΝ ΔΟΚΙΜΩΝ ΣΤΟΝ ΑΞΙΩΜΑΤΙΚΟ ΣΥΜΒΟΛΑΙΩΝ ΓΙΑ ΕΛΕΓΧΟ ΚΑΙ ΑΠΟΔΟΧΗ ΠΡΙΝ ΤΗΝ ΕΚΚΙΝΗΣΗ ΤΗΣ ΚΑΤΑΣΚΕΥΗΣ ΚΑΙ ΤΩΝ ΕΡΓΑΣΙΩΝ.

12. NO SPRINKLER PIPING CAN BE PASSING THROUGH STAIRS, ELECTRICAL OR TELECOMMUNICATION ROOMS OR OVER ELECTRICAL PANELS/EQUIPMENT.

EQUIPMENT, PIPING, DUCTWORK, MACHINERY, ETC THAT DOES NOT SERVE THE STAIRS, ELECTRICAL OR TELECOMMUNICATIONS ROOM MUST NOT BE PROVIDED ABOVE, BELOW (I.E. IN OR UNDER SLAB) OR ENTER OR PASS THRU THIS SPACE. ONLY DEDICATED BRANCH SPRINKLER PIPING WILL BE ALLOWED WITHIN EACH OF THE SPACES INDICATED OR SIDEWALL SPRINKLER HEADS MUST BE USED. COORDINATE THE LOCATION OF PIPING WITH ELECTRICAL OR EQUIPMENT AND OTHER

TRADES AND ADJUST.

ΚΑΜΙΑ ΣΩΛΗΝΩΣΗ ΚΑΤΑΙΟΝΙΣΜΟΥ ΔΕΝ ΜΠΟΡΕΙ ΝΑ ΔΙΑΠΕΡΝΑ ΚΛΙΜΑΚΟΣΤΑΣΙΑ, ΗΛΕΚΤΡΟΣΤΑΣΙΑ Ή ΑΣΘΕΝΟΣΤΑΣΙΑ ΄Η ΠΑΝΩ ΑΠΟ ΗΛΕΚΤΡΟΛΟΓΙΚΟΥΣ ΠΙΝΑΚΕΣ/ΕΞΟΠΛΙΣΜΟ. ΕΞΟΠΛΙΣΜΟΣ, ΣΩΛΗΝΩΣΕΙΣ, ΑΕΡΑΓΩΓΟΙ, ΜΗΧΑΝΗΜΑΤΑ, ΚΛΠ. ΠΟΥ ΔΕΝ ΕΞΥΠΗΡΕΤΟΥΝ ΤΑ ΚΛΙΜΑΚΟΣΤΑΣΙΑ, ΗΛΕΚΤΡΟΣΤΑΣΙΑ ΑΣΘΕΝΟΣΤΑΣΙΑ ΔΕΝ ΠΡΕΠΕΙ ΝΑ ΤΟΠΟΘΕΤΟΥΝΤΑΙ ΠΑΝΩ ΑΠΟ, ΚΑΤΩ ΑΠΟ (Π.Χ. ΜΕΣΑ Η ΚΑΤΩ ΑΠΟ ΤΗΝ ΠΛΑΚΑ) Ή ΝΑ ΕΙΣΕΡΧΟΝΤΑΙ Ή ΝΑ ΔΙΑΠΕΡΝΟΥΝ ΑΥΤΟΥΣ ΤΟΥΣ ΧΩΡΟΥΣ. ΜΟΝΟ ΕΙΔΙΚΟΙ ΚΛΑΔΟΙ ΣΩΛΗΝΩΣΕΩΝ ΘΑ ΕΠΙΤΡΕΠΟΝΤΑΙ ΕΝΤΟΣ ΚΑΘΕ ΧΩΡΟΥ ΠΟΥ ΥΠΟΔΕΙΚΝΥΕΤΑΙ ΕΝΑΛΛΑΚΤΙΚΑ ΠΛΕΥΡΙΚΟΥ ΤΥΠΟΥ ΚΕΦΑΛΕΣ ΚΑΤΑΙΟΝΙΣΜΟΥ ΘΑ ΠΡΕΠΕΙ ΝΑ ΧΡΗΣΙΜΟΠΟΙΗΘΟΥΝ. ΣΥΝΤΟΝΙΣΤΕ ΤΙΣ ΘΕΣΕΙΣ ΤΩΝ ΣΩΛΗΝΩΣΕΩΝ ΜΕ ΤΑ ΗΛΕΚΤΡΟΛΟΓΙΚΑ Η ΕΞΟΠΛΙΣΜΟΥΣ ΚΑΙ ΑΛΛΕΣ ΕΙΔΙΚΟΤΗΤΕΣ ΚΑΙ ΤΡΟΠΟΠΟΙΗΣΤΕ.

13. SEISMIC BRACING IS REQUIRED, PROVIDE SEISMIC BRACING PER NFPA 13 AND DRAWINGS. ADD MISC STEEL FOR PIPE SUPPORTS PER NFPA 13.

SEE SEISMIC DESIGN CRITERIA ON DRAWING S-001.

ΑΠΑΙΤΕΙΤΑΙ ΣΕΙΣΜΙΚΗ ΑΝΑΡΤΗΣΗ, ΠΡΟΜΗΘΕΥΣΤΕ ΣΕΙΣΜΙΚΗ ΑΝΑΡΤΗΣΗ ΣΥΜΦΩΝΑ ΜΕ ΤΟΝ NFPA 13 ΚΑΙ ΤΑ ΣΧΕΔΙΑ. ΠΡΟΣΘΕΣΤΕ ΧΑΛΥΒΑ ΓΙΑ ΤΑ ΣΤΗΡΙΓΜΑΤΑ ΤΩΝ ΣΩΛΗΝΩΣΕΩΝ ΣΥΜΦΩΝΑ ΜΕ ΤΟΝ 13. ΒΛΕΠΕ ΚΡΙΤΗΡΙΑ ΣΕΙΣΜΙΚΟΥ ΣΧΕΔΙΑΣΜΟΥ ΣΤΟ ΣΧΕΔΙΟ S-001.

14. PENDANT SPRINKLER HEADS MUST BE PROVIDED ON RETURN BENDS.

ΟΙ ΚΡΕΜΑΣΤΕΣ (ΑΝΕΣΤΡΑΜΕΝΕΣ) ΚΕΦΑΛΕΣ ΚΑΤΑΙΟΝΗΤΗΡΩΝ ΠΡΕΠΕΙ ΝΑ ΤΟΠΟΘΕΤΟΥΝΤΑΙ ΜΕ ΑΝΤΙΣΤΡΟΦΗ ΚΥΡΤΩΣΗ ΣΩΛΗΝΑΣ.

15. PROVIDE A MINIMUM OF 1 M OF CLEARANCE IN FRONT OF EQUIPMENT AND 153 MM BEHIND THE EQUIPMENT (IE CONTROL VALVES, RISERS, ETC).

ΕΞΑΣΦΑΛΙΣΤΕ ΕΛΑΧΙΣΤΟ ΚΕΝΟ 1Μ ΜΠΡΟΣΤΑ ΚΑΙ 153ΜΜ ΠΙΣΩ ΑΠΟ ΤΟΝ ΕΞΟΠΛΙΣΜΟ (Π.Χ. ΒΑΝΕΣ ΕΛΕΓΧΟΥ, ΚΑΤΑΚΟΡΥΦΕΣ ΣΤΗΛΕΣ, ΚΛΠ).

16. MECHANICAL COUPLINGS, GASKETS AND FITTINGS MUST BE FROM THE SAME MANUFACTURER.

ΟΙ ΜΗΧΑΝΙΚΟΙ ΣΥΝΔΕΣΜΟΙ, ΦΛΑΝΤΖΕΣ ΚΑΙ ΕΞΑΡΤΗΜΑΤΑ ΠΡΕΠΕΙ ΝΑ ΕΙΝΑΙ ΑΠΟ ΤΟΝ ΙΔΙΟ ΚΑΤΑΣΚΕΥΑΣΤΗ.

17. SPRINKLER HEADS 2.13 M OR LESS ABOVE THE FLOOR MUST HAVE APPROVED HEADGUARDS. SPRINKLER HEADS AND PIPE MUST BE 203 CM MINIMUM ABOVE FLOOR

IN STAIRS AND CORRIDORS.

ΟΙ ΚΕΦΑΛΕΣ ΚΑΤΑΙΟΝΙΣΜΟΥ ΠΟΥ ΒΡΙΣΚΟΝΤΑΙ 2.13Μ Η ΛΙΓΟΤΕΡΟ ΠΑΝΩ ΑΠΟ ΤΟ ΔΑΠΕΔΟ ΘΑ ΠΡΕΠΕΙ ΝΑ ΦΕΡΟΥΝ ΕΓΚΕΚΡΙΜΕΝΗ ΠΡΟΣΤΑΣΙΑ ΚΕΦΑΛΗΣ. ΟΙ ΚΕΦΑΛΕΣ ΚΑΤΑΙΟΝΙΣΜΟΥ ΚΑΙ ΟΙ ΣΩΛΗΝΕΣ ΠΡΕΠΕΙ ΝΑ ΕΙΝΑΙ ΚΑΤ’ ΕΛΑΧΙΣΤΟΝ 203CM ΠΑΝΩ ΑΠΟ ΤΟ ΔΑΠΕΔΟ ΣΕ ΚΛΙΜΑΚΕΣ ΚΑΙ ΔΙΑΔΡΟΜΟΥΣ.

18. THE USE OF A SIDE OUTLET TEE THAT REQUIRES A DRILLED HOLE IN THE PIPE WITH A WRAP AROUND BAND AND RUBBER GASKET ARE NOT ALLOWED PER UFC 3-600-01.

Η ΧΡΗΣΗ ΠΛΕΥΡΙΚΗΣ ΔΙΑΚΛΑΔΩΣΗΣ ΤΑΦ Η ΟΠΟΙΑ ΑΠΑΙΤΕΙ ΔΙΑΤΡΗΣΗ ΤΡΥΠΑΣ ΣΤΗΝ ΣΩΛΗΝΑ ΜΕ ΠΕΡΙΔΕΣΜΟ ΣΥΣΦΥΞΗΣ ΚΑΙ ΕΛΑΣΤΙΚΗ ΦΛΑΝΤΖΑ ΑΠΑΓΟΡΕΥΕΤΑΙ

ΣΥΜΦΩΝΑ ΜΕ ΤΟΝ UFC 3-600-01.

19. CLEAN, PRE-TREAT, AND PRIME EXPOSED SPRINKLER PIPING. PAINT EXPOSED SPRINKLER PIPING WITH ONE COAT OF RED ALKYD GLASS ENAMEL. PROVIDE LABELS AND FLOW ARROWS AFTER PAINT IS DRY. FLOW ARROWS NOT REQUIRED ON LOOP OR GRIDDED SYSTEMS.

ΚΑΘΑΡΙΣΤΕ, ΠΡΟΕΤΟΙΜΑΣΤΕ ΚΑΙ ΑΣΤΑΡΩΣΤΕ ΤΙΣ ΕΚΤΕΘΕΙΜΕΝΕΣ ΣΩΛΗΝΩΣΕΙΣ ΚΑΤΑΙΟΝΙΣΜΟΥ. ΒΑΨΤΕ ΤΙΣ ΕΚΤΕΘΕΙΜΕΝΕΣ ΣΩΛΗΝΩΣΕΙΣ ΚΑΤΑΙΟΝΙΣΜΟΥ ΜΕ ΕΝΑ ΣΤΡΩΜΑ ΚΟΚΚΙΝΟΥ ΧΡΩΜΑΤΟΣ ΣΜΑΛΤΟ ALKYD GLASS ENAMEL. ΠΡΟΜΗΘΕΥΣΤΕ ΤΑΜΠΕΛΕΣ ΚΑΙ ΒΕΛΗ ΡΟΗΣ ΜΕΤΑ ΤΟ ΣΤΕΓΝΩΜΑ ΤΟΥ ΧΡΩΜΑΤΟΣ. ΒΕΛΗ ΡΟΗΣ ΔΕΝ ΑΠΑΙΤΟΥΝΤΑΙ ΣΕ ΣΥΣΤΗΜΑΤΑ ΒΡΟΓΧΟΥ Η ΔΙΚΤΥΟΥ (ΟΠΟΥ ΔΗΛΑΔΗ Η ΚΑΤΕΥΘΥΝΣΗ ΡΟΗΣ ΜΠΟΡΕΙ ΝΑ ΜΕΤΑΒΑΛΛΕΤΑΙ)

20. MATERIALS MUST BE U.L. LISTED AND/OR FM APPROVED.

ΤΑ ΥΛΙΚΑ ΠΡΕΠΕΙ ΝΑ ΕΙΝΑΙ ΕΓΚΕΚΡΙΜΕΝΑ ΚΑΤΑ U.L. Η/ΚΑΙ ΚΑΤΑ FM.

21. CUTTING STRUCTURAL MEMBERS OR REINFORCING FOR PASSAGE OF PIPES OR FOR PIPE-HANGER FASTENINGS WILL NOT BE PERMITTED. PIPES THAT MUST PENETRATE CONCRETE WALLS OR CONCRETE FLOORS MUST BE PROVIDED WITH CAST-IN-PLACE PIPE SLEEVES. PIPES THAT MUST PENETRATE MASONRY WALLS

MUST BE CORE-DRILLED WITHOUT CUTTING REINFORCING AND PROVIDED WITH PIPE SLEEVES.

ΚΟΨΙΜΟ ΔΟΜΙΚΩΝ ΣΤΟΙΧΕΙΩΝ Η ΕΝΙΣΧΥΣΗ ΓΙΑ ΠΕΡΑΣΜΑ ΤΩΝ ΣΩΛΗΝΩΝ Η ΓΙΑ ΠΡΟΣΔΕΣΗ ΤΩΝ ΑΝΑΡΤΗΣΕΩΝ ΣΩΛΗΝΩΝ ΔΕΝ ΘΑ ΕΠΙΤΡΑΠΕΙ. ΟΙ ΣΩΛΗΝΕΣ ΠΟΥ ΘΑ ΠΡΕΠΕΙ ΝΑ ΔΙΑΠΕΡΑΣΟΥΝ ΤΟΙΧΟΥΣ Η ΔΑΠΕΔΑ ΑΠΟ ΣΚΥΡΟΔΕΜΑ ΠΡΕΠΕΙ ΝΑ ΠΡΟΜΗΘΕΥΟΝΤΑΙ ΜΕ ΜΑΝΔΥΕΣ ΣΩΛΗΝΩΣΕΩΝ ΧΥΤΟΥΣ ΕΠΙ ΤΟΠΟΥ. ΓΙΑ ΤΙΣ ΣΩΛΗΝΕΣ ΠΟΥ ΠΡΕΠΕΙ ΝΑ ΔΙΑΠΕΡΑΣΟΥΝ ΠΛΙΝΘΟΚΤΙΣΤΗ ΤΟΙΧΟΠΟΙΙΑ, ΘΑ ΓΙΝΕΤΑΙ ΚΥΚΛΙΚΗ ΑΔΙΑΤΑΡΑΚΤΗ ΔΙΑΤΡΗΣΗ ΧΩΡΙΣ ΝΑ ΚΟΒΕΤΑΙ Η ΕΝΙΣΧΥΣΗ ΚΑΙ ΝΑ ΠΑΡΕΧΟΝΤΑΙ ΜΕ ΜΑΝΔΥΕΣ

ΣΩΛΗΝΩΣΕΩΝ.

ACCESS

ΠΡΟΣΒΑΣΗ

ACC

ΡΥΘΜΙΖΟΜΕΝΟ

ΠΑΝΩ ΑΠΟ ΤΕΛΕΙΩΜΕΝΟ ΔΑΠΕΔΟ

ΕΝΑΛΛΑΚΤΙΚΟ

ΚΑΤΑ ΠΡΟΣΕΓΓΙΣΗ

ΑΡΧΙΤΕΚΤΟΝΙΚΟΣ

ΚΤΙΡΙΟ

ΚΑΤΩ ΜΕΡΟΣ

ΓΡΑΜΜΗ ΚΕΝΤΡΟΥ

ΟΡΟΦΗ

ΜΟΝΑΔΑ ΤΟΙΧΟΠΟΙΙΑ ΑΠΟ ΣΚΥΡΟΔΕΜΑ

ΣΥΝΔΕΣΗ / ΣΥΝΔΕΣΤΕ

ΔΙΑΔΡΟΜΟΣ

ΛΕΠΤΟΜΕΡΕΙΑ

ΔΙΑΜΕΤΡΟΣ

ΔΙΑΣΤΑΣΗ

ΤΜΗΜΑ

ΣΧΕΔΙΟ

ΚΑΘΕ

ΥΨΟΜΕΤΡΟ - ΟΨΗ

ΕΞΟΠΛΙΣΜΟΣ

ΠΙΝΑΚΑΣ ΕΛΕΓΧΟΥ ΣΥΝΑΓΕΡΜΟΥ ΠΥΡΚΑΓΙΑΣ

ΣΥΝΔΕΣΗ ΤΗΣ ΠΥΡΟΣΒΕΣΤΙΚΗΣ ΥΠΗΡΕΣΙΑΣ

ΠΥΡΟΣΒΕΣΤΙΚΟΣ ΚΡΟΥΝΟΣ

ΦΛΑΝΤΖΑ

ΔΑΠΕΔΟ

ΠΑΤΗΜΑ

ΤΥΠΟΠΟΙΗΜΕΝΟΣ ΔΕΙΚΤΗΣ

ΓΑΛΒΑΝΙΣΜΕΝΟ

ΥΨΗΛΟΥ ΟΓΚΟΥ ΧΑΜΗΛΗΣ ΤΑΧΥΤΗΤΑΣ

ΣΥΜΦΩΝΑ ΜΕ

ΦΩΤΙΣΜΟΣ

ΑΝΘΡΩΠΟΘΥΡΙΔΑ

ΜΕΓΙΣΤΟ

ΚΑΤΑΣΚΕΥΑΣΤΗΣ

ΕΛΑΧΙΣΤΟ

ΜΗΧΑΝΙΚΗ ΣΥΝΔΕΣΗ

ΔΙΑΦΟΡΑ

ΤΟΠΟΘΕΤΗΜΕΝΟΣ

ΤΟΠΟΘΕΤΗΣΗ

ΑΡΙΘΜΟΣ

ΟΝΟΜΑΣΤΙΚΟΣ

ΑΜΕΡΙΚΑΝΙΚΟ ΣΠΕΙΡΩΜΑ ΣΩΛΗΝΩΣΕΩΝ (NPT)

ΧΩΡΙΣ ΚΛΙΜΑΚΑ

ΣΤΟ ΚΕΝΤΡΟ

ΕΞΩΤΕΡΙΚΗ ΔΙΑΜΕΤΡΟΣ

ΦΑΣΗ

ΠΙΕΣΗ

ΥΠΟΓΕΙΑ ΒΑΝΑ ΜΕ ΕΝΔΕΙΞΗ ΘΕΣΗΣ ΣΕ ΥΠΕΡΓΕΙΟ ΣΤΥΛΙΣΚΟ

ΑΚΤΙΝΑ ΚΥΚΛΟΥ

ΑΠΑΙΤΕΙΤΑΙ

ΣΤΡΟΦΕΣ ΑΝΑ ΛΕΠΤΟ

ΦΥΛΛΟ - ΣΧΕΔΙΟ

ΠΡΟΔΙΑΓΡΑΦΗ

ΚΑΤΑΙΟΝΗΤΗΡΑΣ

ΤΕΤΡΑΓΩΝΟ

ΘΕΡΜΟΚΡΑΣΙΑ

ΤΥΠΙΚΟ

ΕΚΤΟΣ ΕΑΝ ΑΝΑΦΕΡΕΤΑΙ ΔΑΙΦΟΡΕΤΙΚΑ

ΟΓΚΟΣ

ΜΕ

ΧΩΡΙΣ

ΣΥΓΚΟΛΛΗΤΟ ΠΛΕΓΜΑ ΣΥΡΜΑΤΟΣ

*NFPA 1 - 2021 EDITION, FIRE CODE.

*NFPA 1 - ΕΚΔΟΣΗ 2021 , ΚΩΔΙΚΑΣ ΠΥΡΚΑΓΙΑΣ.

ΚΑΤΩ

SM

D

C

B

1 2 3 4 5

NOT TO SCALE

1568016

DWG

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.

SCALE:

N62470-23-C-XXXX

RICHARD L STEPHENS, P.E.

LMM/MWL

CHIEF ENG/ARCH

DES DRW CHK

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

SY

M

D

ES

C R

IP

TI

O N

D

AT

E

AP

PR

S O

U D

A B

A

YA

DRAWFORM REVISION: 25 AUGUST 2020

1 2 3 4 5

D

C

B

A

UNCLASSIFIED

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

A T

L A

N T

IC

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

N O

R F

O L K

V

A L A

N T

C A

P

IT

A L

IM

P

R O

V E

M E

N T

S

BRANCH MANAGER

PM/DM

SATISFACTORY TO DATE

FIRE PROTECTION DPS (DOUG STULTZ)

DPS (DOUG STULTZ)

/3

/2

:1 :5

A

M d c1 vs

\F

E D

P R

J\

\F ir e

P ro te ct io n \P

-1

-F

P

R

.r vt

03/31/2023

F-001

CLO WPS BVP

P J

O

IN

T M

O B

IL

IT

Y P

R O

C E

S S

IN

G

F A

C

IL

IT

Y

S O

U D

A B

A Y

G

R E

E C

E

L E

G E

N D

14068631

F -0

Υ Π

Ο Μ

Ν Η

Μ Α

APPROVED BY: PAM COWDEN, P.E.

FEAD BRANCH HEAD

VIA SAT-TO FORM

XXX

SO

CARGO BAY (MISCELLANEOUS

STORAGE LESS THAN 12 FEET ( 3.67 M)

HIGH)

LH OH

CH2M

1/12/17

1. EXTENDED COVERAGE SPRINKLERS NOT ALLOWED.

2. INCREASE DESIGN AREA 30% FOR ROOF SLOPES OVER 2 IN 12.

230 SM 230 SM140 SMDESIGN AREA (NOTE 1 & 2)

4,831 SM/SYSTEM

9.1 M

950 LPM

12 SM

QUICK RESPONSE TYPE

60 MIN

8.0 LPM/SM

SPECIAL OCCUPANCY

INTERMEDIATE TEMPERATURE

RATING 80°C

3.96 M MAX

HYDRAULIC NODE

NOT SPRINKLERED

ECCENTRIC REDUCER

CONCENTRIC REDUCER

ELBOW, 45 DEGREE

TEE

ELBOW, 90 DEGREE

SWING CHECK

BALL

GLOBE

BUTTERFLY

GATE

TEE DOWN

ELBOW DOWN

UNION

LATERAL DOWN

LATERAL UP

TEE UP

SINGLE LINE

ΜΟΝΟΓΡΑΜΜΙΚΟ

DOUBLE LINE

ΔΙΓΡΑΜΜΙΚΟ

REST ROOMS, OFFICES,

CORRIDORS, STAIRS, BREAK ROOMS

COMM ROOMS, ELECTRICAL ROOMS,

MECHANICAL ROOMS, ELEV ROOMS,

JANITORS ROOMS

11,239 LPM

4,111 LPM

TEST PERFORMED BY:

3.99 BAR

4.48 BAR

WATER SUPPLY DATA

TIME OF TEST

DATE OF TEST

FLOW @ 1.38 BAR

RESIDUAL PRESSURE

STATIC PRESSURE

FLOW TEST

FLOW @ RESIDUAL

12 SM

K-FACTOR OF

SPRINKLER NOZZLE

PIPE "C" FACTOR

MAXIMUM CEILING HEIGHT 9.1 M9.1 M

ORDINARY TEMPERATURE

RATING 71°C

ORDINARY TEMPERATURE

RATING 71°C

ORDINARY HAZARDLIGHT HAZARD

4,831 SM/SYSTEM

3.96 M MAX

950 LPM

8.0 LPM/SM

4.6 M MAX

4,831 SM/SYSTEM

950 LPM

21 SM

4.0 LPM/SM

1. SYMBOLS INDICATED HERE AND NOT USED IN THE CONTRACT DOCUMENTS DO NOT APPLY TO THIS

PROJECT. ADDITIONAL SYMBOLS MAY BE INDICATED IN THE CONTRACT DOCUMENTS.

ΣΥΜΒΟΛΑ ΠΟΥ ΣΥΜΠΕΡΙΛΑΜΒΑΝΟΝΤΑΙ ΕΔΩ ΚΑΙ ΔΕΝ ΧΡΗΣΙΜΟΠΟΙΟΥΝΤΑΙ ΣΤΑ ΕΓΓΡΑΦΑ ΤΗΣ ΣΥΜΒΑΣΗΣ

ΔΕΝ ΕΦΑΡΜΟΖΟΝΤΑΙ ΣΤΟ ΠΑΡΟΝ ΕΡΓΟ. ΠΡΟΣΘΕΤΑ ΣΥΜΒΟΛΑ ΜΠΟΡΟΥΝ ΝΑ ΑΝΑΓΡΑΦΟΝΤΑΙ ΣΤΑ

ΕΓΓΡΑΦΑ ΤΗΣ ΣΥΜΒΑΣΗΣ.

LATERAL BRACING

LONGITUDINAL BRACING

FOUR-WAY BRACING

NOTE:

FLOOR AREA

THROUGH ONE RISER

SPACE BETWEEN SPRINKLERS

SPRINKLER TEMP RATING

DESIGN DENSITY

60 MIN

QUICK RESPONSE TYPEQUICK RESPONSE TYPE

60 MIN

HOSE STREAM

COVERAGE PER SPRINKLER

SPRINKLER TYPE

DURATION TIME

APPLICATION AREA

DESCRIPTION

HAZARD

14:00

FIRE SUPPRESSION REQUIREMENTS

ΑΠΑΙΤΗΣΕΙΣ ΓΙΑ ΤΗΝ ΚΑΤΑΠΟΛΕΜΗΣΗ ΤΗΣ ΠΥΡΚΑΓΙΑΣ

FIRE SUPPRESSION SYMBOLS

ΣΥΜΒΟΛΑ ΓΙΑ ΤΗΝ ΚΑΤΑΣΒΕΣΤΙΚΟΥ ΣΥΣΤΗΜΑΤΟΣ ΠΥΡΚΑΓΙΑΣ

FEC-1

FIRE EXTINGUISHER

WALL BRACKET MOUNTED

WALL MOUNTED

EXTINGUISHER CABINET

FE-3

FEC-2

SEMI-RECESSED FIRE

EXTINGUISHER CABINET

PENDANT SPRINKLER

APPROXIMATE HANGER

LOCATION

UPRIGHT SPRINKLER

ELBOW UP

ΚΑΜΠΥΛΗ ΠΡΟΣ ΤΑ ΠΑΝΩ

ΚΑΠΛΥΛΗ ΠΡΟΣ ΤΑ ΚΑΤΩ

ΔΙΑΚΛΑΔΩΣΗ ΠΡΟΣ ΤΑ ΠΑΝΩ

ΔΙΑΚΛΑΔΩΣΗ ΠΡΟΣ ΤΑ ΠΑΝΩ

ΠΛΕΥΡΙΚΗ ΔΙΑΚΛΑΔΩΣΗ

ΠΡΟΣ ΤΑ ΠΑΝΩ

ΠΛΕΥΡΙΚΗ ΔΙΑΚΛΑΔΩΣΗ

ΠΡΟΣ ΤΑ ΚΑΤΩ

ΟΜΟΚΕΝΤΡΗ ΑΛΛΑΓΗ ΔΙΑΤΟΜΗΣ

ΕΚΚΕΝΤΡΗ ΑΛΛΑΓΗ ΔΙΑΤΟΜΗΣ

ΣΥΝΔΕΣΜΟΣ

ΚΑΜΠΥΛΗ 90 ΜΟΙΡΩΝ

ΤΑΦ

ΚΑΜΠΥΛΗ 45 ΜΟΙΡΩΝ

ΣΥΡΤΟΥ

ΠΕΤΑΛΟΥΔΑΣ

ΕΔΡΑΣ

ΣΦΑΙΡΙΚΗ

ΕΛΕΓΧΟΥ ΡΟΗΣ

ΧΩΡΙΣ ΚΑΤΑΙΟΝΗΤΗΡΕΣ

ΥΔΡΑΥΛΙΚΟΣ ΚΟΜΒΟΣ

ΕΓΚΑΡΣΙΑ ΣΤΗΡΙΞΗ

ΜΕ ΒΡΑΧΙΟΝΑ

ΔΙΑΜΗΚΗΣ ΣΤΗΡΙΞΗ

ΜΕ ΒΡΑΧΙΟΝΑ

ΣΤΗΡΙΞΗ ΤΕΣΣΑΡΩΝ

ΚΑΤΕΥΘΥΝΣΕΩΝ

ΜΕ ΒΡΑΧΙΟΝΕΣ

ΚΑΤΑ ΠΡΟΣΕΓΓΙΣΗ ΘΕΣΗ

ΑΝΑΡΤΟΥΝΕΝΗΣ ΣΤΗΡΙΞΗΣ

ΕΠΙΤΟΙΧΟ ΝΤΟΥΛΑΠΙ

ΠΥΡΟΣΒΕΣΤΗΡΑ

ΗΜΙΧΑΝΤΡΩΜΕΝΟ ΝΤΟΥΛΑΠΙ

ΠΥΡΟΣΒΕΣΤΗΡΑ

ΚΑΘΕΤΟΣ ΚΑΤΑΙΟΝΗΤΗΡΑΣ (ΟΡΘΙΟΣ)

ΠΥΡΟΣΒΕΣΤΗΡΑΣ ΤΟΠΟΘΕΤΗΜΕΝΟΣ

ΣΕ ΕΠΙΤΟΙΧΟ ΑΓΚΥΣΤΡΟ

ΚΡΕΜΑΣΤΟΣ ΚΑΤΑΙΟΝΗΤΗΡΑΣ

(ΑΝΕΣΤΡΑΜΕΝΟΣ)

ΠΥΚΝΟΤΗΤΑ ΣΧΕΔΙΑΣΜΟΥ

ΧΡΟΝΟΣ ΔΙΑΡΚΕΙΑΣ

ΕΙΔΟΣ ΚΑΤΑΙΟΝΗΤΗΡΑ

ΚΑΛΥΨΗ ΑΝΑ ΚΑΤΑΙΟΝΗΤΗΡΑ

ΡΟΗ ΜΑΝΙΚΑΣ

ΠΕΡΙΟΧΗ ΣΧΕΔΙΑΣΜΟΥ

(ΠΑΡΑΤΗΡΗΣΕΙΣ 1 & 2)

ΤΑΞΙΝΟΜΗΣΗ ΘΕΡΜΟΚΡΑΣΙΑΣ

ΚΑΤΑΙΟΝΗΤΗΡΑ

ΜΕΓΙΣΤΟ ΥΨΟΣ ΟΡΟΦΗΣ

ΑΠΟΣΤΑΣΗ ΜΕΤΑΞΥ

ΚΑΤΑΙΟΝΗΤΗΡΩΝ

ΕΠΙΦΑΝΕΙΑ ΔΑΠΕΔΟΥ ΔΙΑ ΜΕΣΟΥ

ΜΙΑΣ ΚΑΤΑΚΟΡΥΦΟΥ.

ΣΥΝΤΕΛΕΣΤΗΣ Κ

ΤΟΥ ΑΚΡΟΦΥΣΙΟΥ ΚΑΤΑΙΟΝΗΤΗΡΑ

ΣΥΝΤΕΛΕΣΤΗΣ "C" ΣΩΛΗΝΑΣ

60 ΛΕΠΤΑ

ΤΥΠΟΥ ΓΡΗΓΟΡΗΣ ΑΠΟΚΡΙΣΗΣ

ΣΥΝΗΘΗΣ ΤΑΞΙΝΟΜΗΣΗ

ΘΕΡΜΟΚΡΑΣΙΑΣ 71οC

ΜΕΓΙΣΤΟ 4.6 ΜΕΤΡΑ

4,831 SM/ΣΥΣΤΗΜΑ 4,831 SM/ΣΥΣΤΗΜΑ

ΜΕΓΙΣΤΟ 3.96 ΜΕΤΡΑ

ΣΥΝΗΘΗΣ ΤΑΞΙΝΟΜΗΣΗ

ΘΕΡΜΟΚΡΑΣΙΑΣ 71οC

ΤΥΠΟΥ ΓΡΗΓΟΡΗΣ ΑΠΟΚΡΙΣΗΣ

60 ΛΕΠΤΑ 60 ΛΕΠΤΑ

ΤΥΠΟΥ ΓΡΗΓΟΡΗΣ ΑΠΟΚΡΙΣΗΣ

ΕΝΔΙΑΜΕΣΗ ΤΑΞΙΝΟΜΙΣΗ

ΘΕΡΜΟΚΡΑΣΙΑΣ 80οC

ΜΕΓΙΣΤΟ 3.96 ΜΕΤΡΑ

4,831 SM/ΣΥΣΤΗΜΑ

ΠΕΡΙΟΧΗ ΕΦΑΡΜΟΓΗΣ

ΑΠΟΧΩΡΗΤΗΡΙΑ, ΓΡΑΦΕΙΑ, ΔΙΑΔΡΟΜΟΙ,

ΚΛΙΜΑΚΟΣΤΑΣΙΑ, ΧΩΡΟΙ ΔΙΑΛΛΕΙΜΑΤΟΣ

ΧΩΡΟΙ ΤΗΛΕΠΙΚΟΙΝΩΝΙΑΣ, ΧΩΡΟΙ

ΗΛΕΚΤΡΟΛΟΓΙΚΩΝ, ΧΩΡΟΙ ΜΗΧΑΝΟΛΟΓΙΚΩΝ,

ΧΩΡΟΙ ΑΝΕΛΚΥΣΤΗΡΑ, ΧΩΡΟΙ ΕΠΙΣΤΑΤΗ

ΠΕΡΙΟΧΗ ΕΜΠΟΡΕΥΜΑΤΩΝ

(ΑΠΟΘΗΚΕΥΣΗΣ ΔΙΑΦΟΡΩΝ ΕΙΔΩΝ

ΜΙΚΡΟΤΕΡΗ ΑΠΟ 12 ΠΟΔΙΑ (3.67 Μ)

ΥΨΟΥΣ)

ΣΥΝΗΘΗΣ ΚΙΝΔΥΝΟΣ ΕΙΔΙΚΗΣ ΠΑΡΟΥΣΙΑΣ

ΑΤΟΜΩΝ

ΕΛΑΦΡΥΣ ΚΙΝΔΥΝΟΣΚΙΝΔΥΝΟΣ

ΠΕΡΙΓΡΑΦΗ

ΣΤΑΤΙΚΗ ΠΙΕΣΗ

ΠΑΡΑΜΕΝΟΥΣΑ ΠΙΕΣΗ

ΡΟΗ @ ΠΑΡΑΜΕΝΟΥΣΑ

ΡΟΗ @ 1.38 BAR

ΗΜΕΡΟΜΗΝΙΑ ΔΟΚΙΜΗΣ

Η ΔΟΚΙΜΗ

ΥΛΟΠΟΙΗΘΗΚΕ ΑΠΟ:

CH2M

ΔΟΚΙΜΗ ΡΟΗΣ

ΔΕΔΟΜΕΝΑ ΠΑΡΟΧΗΣ ΝΕΡΟΥ

ΩΡΑ ΔΟΚΙΜΗΣ

ΕΚΤΕΤΑΜΕΝΗΣ ΚΑΛΥΨΗΣ ΚΑΤΑΙΟΝΗΤΗΡΕΣ ΔΕΝ ΕΠΙΤΡΕΠΟΝΤΑΙ.

ΑΥΞΗΣΤΕ ΤΗΝ ΠΕΡΙΟΧΗ ΣΧΕΔΙΑΣΜΟΥ ΚΑΤΑ 30% ΓΙΑ ΚΛΙΣΕΙΣ ΟΡΟΦΗΣ ΑΝΩ ΤΩΝ 2 ΣΤΑ 12.

OR

OR

OR

OR

OR

NS

OR

OR

OR

OR

SM

D

C

B

1 2 3 4 5

NOT TO SCALE

1568016

DWG

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.

SCALE:

N62470-23-C-XXXX

RICHARD L STEPHENS, P.E.

LMM/MWL

CHIEF ENG/ARCH

DES DRW CHK

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

TI

O N

D A

TE

A

P P

R

S O

U D

A B

A

YA

DRAWFORM REVISION: 25 AUGUST 2020

1 2 3 4 5

D

C

B

A

UNCLASSIFIED

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

A T

L A

N T

IC

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

N O

R F

O L K

V

A L A

N T

C A

P

IT

A L I M

P R

O V

E M

E N

T S

BRANCH MANAGER

PM/DM

SATISFACTORY TO DATE

FIRE PROTECTION DPS (DOUG STULTZ)

DPS (DOUG STULTZ)

/3

/2

:1 :0

A

M d c v s

\F

E D

P R

J \6

\F ir e

P ro te c ti o n \P

-1

-F

P

R

.r v t

03/31/2023

F-002

CLO WPS BVP

P J

O

IN

T M

O B

IL

IT

Y P

R O

C E

S S

IN

G

F A

C

IL

IT

Y

S O

U D

A B

A Y

G

R E

E C

E

L E

G E

N D

14068632

F -0

Υ Π

Ο Μ

Ν Η

Μ Α

APPROVED BY: PAM COWDEN, P.E.

T ectonic Cop yright 2007

T ectonic Cop yright 2007

Tectonic Copyright 2007

T ectonic Cop yright 2007

Tectonic Copyright 2007

T ectonic Cop yright 2007

T ectonic Cop yright 2007

T ectonic Cop yright 2007

T ectonic Cop yright 2007

Tectonic Copyright 2007

T ectonic Cop yright 2007

Tectonic Copyright 2007

T ectonic Cop yright 2007

T ectonic Cop yright 2007

T ectonic Cop yright 2007

T ectonic Cop yright 2007

T ectonic Cop yright 2007

Tectonic Copyright 2007 Tectonic Copyright 2007

T ectonic Cop yright 2007

Tectonic Copyright 2007

T ectonic Cop yright 2007

T ectonic Cop yright 2007

T ectonic Cop yright 2007

T ectonic Cop yright 2007

T ectonic Cop yright 2007

T ectonic Cop yright 2007

T ectonic Cop yright 2007

SPRINKLER HAZARD CLASSIFICATION

ΚΑΤΑΤΑΞΗ ΚΙΝΔΥΝΟΥΚΑΤΑΙΟΝΗΤΗΡΑ

LIGHT HAZARD

ΕΛΑΦΡΥΣ ΚΙΝΔΥΝΟΣ

ORDINARY HAZARD

ΣΥΝΗΘΗΣ ΚΙΝΔΥΝΟΣ

SPECIAL OCCUPANCY WAREHOUSE, MISC STORAGE

UP TO 3.66 M ABOVE THE FLOOR

ΕΙΔΙΚΗΣ ΠΑΡΟΥΣΙΑΣ ΑΤΟΜΩΝ ΑΠΟΘΗΚΗ, ΑΠΟΘΗΚΗ

ΔΙΑΦΟΡΩΝ ΕΙΔΩΝ ΕΩΣ ΤΟΥ 3.66 Μ ΠΑΝΩ

ΑΠΟ ΤΟ ΔΑΠΕΔΟ

1 2 3 4 5 6 7 108 9 11 12 13 14 14.4 15 16

B

C

D

E

F

G

H

K

J

12.5 14.6

12.3 14.814.512.4

A

G.7

10.5

CA

CB

CC

CD

CE

CF

CG

CH

H.5

14.2

5.1 5.9

E.3

MECH

ELEC

PAX

FUNDS

PAX

PSC

VEST

GATE 1

GATE 2

GATE 3

BAGGAGE

BREAKDOWN

SPEC CAT

STAIR 2

BAGGAGE CLAIM

SPEC CAT CORR

BAGGAGE

BUILDUP

CUSTOMS AND

IMMIGRATION

LOST & FOUND

SECURITY

COMM

MEN

WOMEN

MEN

WOMEN

STAIR 1

ELEV RM

LOBBY

STORAGE

CARGO BAY

SUPPLY CAGED

STORAGE

SUPPLY

STORAGE

CARGO BAY

SUPPLY OFC

DET. MAIN. SPT

OFC

T-LINE

BREAK

RR

RR

RR

PARALOFT

T-LINE OFC

E-28

ELEV

ELEC

MECHANICAL

COMM

FIRE EQ. ROOM

SM

G H C D

B A

EF

1 5 8 14 16

CA

CB

CE

CH

CG

B

C

K

G

D

C

B

1 2 3 4 5

1568016

DWG

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.

SCALE:

N62470-23-C-XXXX

RICHARD L STEPHENS, P.E.

LMM/MWL

CHIEF ENG/ARCH

DES DRW CHK

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

TI

O N

D A

TE

A

P P

R

S O

U D

A B

A Y

SHEET KEYED NOTES:

ΠΑΡΑΤΗΡΗΣΕΙΣ ΣΧΕΔΙΟΥ:

GENERAL NOTES:

ΓΕΝΙΚΕΣ ΠΑΡΑΤΗΡΗΣΕΙΣ:

A KEYPLAN:

ΣΧΕΔΙΟ ΚΛΕΙΔΙ:

DRAWFORM REVISION: 25 AUGUST 2020

1 2 3 4 5

D

C

B

A

UNCLASSIFIED

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

A T

L A

N T

IC

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

N O

R F

O L K

V

A L A

N T

C A

P

IT

A L I M

P R

O V

E M

E N

T S

BRANCH MANAGER

PM/DM

SATISFACTORY TO DATE

FIRE PROTECTION DPS (DOUG STULTZ)

DPS (DOUG STULTZ)

/3

/2

:1 :0

A

M d c v s

\F

E D

P R

J \6

\F ir e

P ro te c ti o n \P

-1

-F

P

R

.r v t

03/31/2023

F-110

CLO WPS BVP

P J

O

IN

T M

O B

IL

IT

Y P

R O

C E

S S

IN

G

F A

C

IL

IT

Y

S O

U D

A B

A Y

G

R E

E C

E

F L

O O

R P

L A

N

L E

V E

L

O

V E

R A

L L

14068633

F -1

Κ Α

Τ Ο

Ψ Η

Ε

Π

ΙΠ

Ε Δ

Ο

Σ Υ

Ν Ο

Λ

ΙΚ

Ο

0 15000 30000

MILLIMETRESSCALE 1:300

90003000

1 : 300

FLOOR PLAN - LEVEL 1 - OVERALL

ΚΑΤΟΨΗ - ΕΠΙΠΕΔΟ 1 - ΣΥΝΟΛΙΚΟ

1. FIRE EQUIPMENT ROOM.

ΔΩΜΑΤΙΟ ΕΞΟΠΛΙΣΜΟΥ ΠΥΡΟΣΒΕΣΗΣ.

2. FORK LIFT AND CARGO PATHS.

ΔΙΑΔΡΟΜΕΣ ΠΕΡΟΝΟΦΟΡΟΥ ΑΝΥΨΩΤΙΚΟΥ ΚΑΙ ΕΜΠΟΡΕΥΜΑΤΩΝ.

3. MAIN ENTRANCE.

ΚΥΡΙΑ ΕΙΣΟΔΟΣ.

A. REFER TO DRAWING F-001 FOR LEGEND, ABBREVIATIONS AND

FIRE SPRINKLER NOTES.

ΑΝΑΤΡΕΞΤΕ ΣΤΟ ΣΧΕΔΙΟ F-001 ΓΙΑ ΤΑ ΥΠΟΜΝΗΜΑΤΑ, ΤΙΣ

ΣΥΝΤΟΜΟΓΡΑΦΙΕΣ ΚΑΙ ΤΙΣ ΠΑΡΑΤΗΡΗΣΕΙΣ ΤΩΝ ΚΑΤΑΙΟΝΗΤΗΡΩΝ

ΠΥΡΚΑΓΙΑΣ.

B. REFER TO LIFE SAFETY PLANS FOR LOCATIONS OF FIRE RATED

WALLS.

ΑΝΑΤΡΕΞΤΕ ΣΤΑ ΣΧΕΔΙΑ ΠΑΘΗΤΙΚΗΣ ΠΥΡΟΠΡΟΣΤΑΣΙΑΣ ΓΙΑ ΤΙΣ

ΘΕΣΕΙΣΤΩΝ ΔΙΑΒΑΘΜΙΣΜΕΝΩΝ ΤΟΙΧΩΜΑΤΩΝ ΠΥΡΚΑΓΙΑΣ.

C. PENETRATION OF WALL OR FLOORS MUST BE SEALED.

SEE DETAILS C1/F-503 AND C4/F503.

ΟΙ ΔΙΑΤΡΗΣΕΙΣ ΣΤΑ ΔΑΠΕΔΑ ΚΑΙ ΤΟΥΣ ΤΟΙΧΟΥΣ ΠΡΕΠΕΙ ΝΑ

ΣΦΡΑΓΙΖΟΝΤΑΙ ΚΑΤΑΛΛΗΛΩΣ. ΔΕΙΤΕ ΤΙΣ ΛΕΠΤΟΜΕΡΕΙΕΣ

C1/F-503 ΚΑΙ C4/F503.

D. SEISMIC BRACING IS REQUIRED. SEISMIC BRACING MUST BE

PROVIDED PER NFPA 13 AND DETAILS B1/F-505.

ΣΕΙΣΜΙΚΗ ΣΤΗΡΙΞΗ ΑΠΑΙΤΕΙΤΑΙ. Η ΣΕΙΣΜΙΚΗ ΣΤΗΡΙΞΗ ΠΡΕΠΕΙ ΝΑ

ΕΓΚΑΤΑΣΤΑΘΕΙ ΣΥΜΦΩΝΑ ΜΕ ΤΟΝ NFPA 13

ΚΑΙ ΤΙΣ ΛΕΠΤΟΜΕΡΕΙΕΣ B1/F-503.

PLAN NORTH

1:300

APPROVED BY: PAM COWDEN, P.E.

M A

T C

H L

IN

E

S

E E

S H

E E

T Γ Ρ

Α Μ

Μ Η

Σ Υ

Ν Α

Ρ Μ

Ο Γ Η

Σ

Β Λ

Ε Π

Ε Σ

Χ Ε

Δ

ΙΟ

F -1

F -1

MATCHLINE - SEE SHEET

ΓΡΑΜΜΗ ΣΥΝΑΡΜΟΓΗΣ -

ΒΛΕΠΕ ΣΧΕΔΙΟ

F-114

F-114

14 14.4 15 16

G

H

K

J

14.6

14.814.514.2

GATE 2

A1

F-303

SPRINKLER HAZARD CLASSIFICATION

ΚΑΤΑΤΑΞΗ ΚΙΝΔΥΝΟΥΚΑΤΑΙΟΝΗΤΗΡΑ

LIGHT HAZARD

ΕΛΑΦΡΥΣ ΚΙΝΔΥΝΟΣ

ORDINARY HAZARD

ΣΥΝΗΘΗΣ ΚΙΝΔΥΝΟΣ

SPECIAL OCCUPANCY WAREHOUSE, MISC STORAGE

UP TO 3.66 M ABOVE THE FLOOR

ΕΙΔΙΚΗΣ ΠΑΡΟΥΣΙΑΣ ΑΤΟΜΩΝ ΑΠΟΘΗΚΗ, ΑΠΟΘΗΚΗ

ΔΙΑΦΟΡΩΝ ΕΙΔΩΝ ΕΩΣ ΤΟΥ 3.66 Μ ΠΑΝΩ

ΑΠΟ ΤΟ ΔΑΠΕΔΟ

SM

A

1 5 8 14 16

CA

CB

CE

CH

CG

B

C

K

G

D

C

B

1 2 3 4 5

1568016

DWG

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.

SCALE:

N62470-23-C-XXXX

RICHARD L STEPHENS, P.E.

LMM/MWL

CHIEF ENG/ARCH

DES DRW CHK

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

TI

O N

D A

TE

A

P P

R

S O

U D

A B

A Y

SHEET KEYED NOTES:

ΠΑΡΑΤΗΡΗΣΕΙΣ ΣΧΕΔΙΟΥ:

GENERAL NOTES:

ΓΕΝΙΚΕΣ ΠΑΡΑΤΗΡΗΣΕΙΣ:

A KEYPLAN:

ΣΧΕΔΙΟ ΚΛΕΙΔΙ:

DRAWFORM REVISION: 25 AUGUST 2020

1 2 3 4 5

D

C

B

A

UNCLASSIFIED

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

A T

L A

N T

IC

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

N O

R F

O L K

V

A L A

N T

C A

P

IT

A L I M

P R

O V

E M

E N

T S

BRANCH MANAGER

PM/DM

SATISFACTORY TO DATE

FIRE PROTECTION DPS (DOUG STULTZ)

DPS (DOUG STULTZ)

/3

/2

:1 :0

A

M d c v s

\F

E D

P R

J \6

\F ir e

P ro te c ti o n \P

-1

-F

P

R

.r v t

03/31/2023

F-111

CLO WPS BVP

P J

O

IN

T M

O B

IL

IT

Y P

R O

C E

S S

IN

G

F A

C

IL

IT

Y

S O

U D

A B

A Y

G

R E

E C

E

F L

O O

R P

L A

N

L E

V E

L

S

E C

T O

R A

14068634

F -1

Κ Α

Τ Ο

Ψ Η

Ε

Π

ΙΠ

Ε Δ

Ο

Τ Ο

Μ Ε

Α Σ

Α

1 : 100

FLOOR PLAN - LEVEL 1 - SECTOR A

ΚΑΤΟΨΗ - ΕΠΙΠΕΔΟ 1 - ΤΟΜΕΑΣ Α

0 5000 10000

MILLIMETRESSCALE 1:100

30001000

A. REFER TO DRAWING F-001 FOR LEGEND, ABBREVIATIONS AND

FIRE SPRINKLER NOTES.

ΑΝΑΤΡΕΞΤΕ ΣΤΟ ΣΧΕΔΙΟ F-001 ΓΙΑ ΤΑ ΥΠΟΜΝΗΜΑΤΑ, ΤΙΣ

ΣΥΝΤΟΜΟΓΡΑΦΙΕΣ ΚΑΙ ΤΙΣ ΠΑΡΑΤΗΡΗΣΕΙΣ ΤΩΝ ΚΑΤΑΙΟΝΗΤΗΡΩΝ

ΠΥΡΚΑΓΙΑΣ.

B. REFER TO LIFE SAFETY PLANS FOR LOCATIONS OF FIRE RATED

WALLS.

ΑΝΑΤΡΕΞΤΕ ΣΤΑ ΣΧΕΔΙΑ ΠΑΘΗΤΙΚΗΣ ΠΥΡΟΠΡΟΣΤΑΣΙΑΣ ΓΙΑ ΤΙΣ

ΘΕΣΕΙΣ ΤΩΝ ΔΙΑΒΑΘΜΙΣΜΕΝΩΝ ΤΟΙΧΩΜΑΤΩΝ ΠΥΡΚΑΓΙΑΣ.

C. PENETRATION OF WALL OR FLOORS MUST BE SEALED.

SEE DETAILS C1/F-503 AND C4/F503.

ΟΙ ΔΙΑΤΡΗΣΕΙΣ ΣΤΑ ΔΑΠΕΔΑ ΚΑΙ ΤΟΥΣ ΤΟΙΧΟΥΣ ΠΡΕΠΕΙ ΝΑ

ΣΦΡΑΓΙΖΟΝΤΑΙ ΚΑΤΑΛΛΗΛΩΣ. ΔΕΙΤΕ ΤΙΣ

ΛΕΠΤΟΜΕΡΕΙΕΣ C1/F-503 ΚΑΙ C4/F503.

D. SEISMIC BRACING IS REQUIRED. SEISMIC BRACING MUST BE

PROVIDED PER NFPA 13 AND DETAILS B1/F-505.

ΣΕΙΣΜΙΚΗ ΣΤΗΡΙΞΗ ΑΠΑΙΤΕΙΤΑΙ. Η ΣΕΙΣΜΙΚΗ ΣΤΗΡΙΞΗ ΠΡΕΠΕΙ ΝΑ

ΕΓΚΑΤΑΣΤΑΘΕΙ ΣΥΜΦΩΝΑ ΜΕ ΤΟΝ NFPA 13

ΚΑΙ ΤΙΣ ΛΕΠΤΟΜΕΡΕΙΕΣ B1/F-505.

PLAN NORTH

1:100

APPROVED BY: PAM COWDEN, P.E.

yright 2007

T ectonic Cop yright 2007

MATCHLINE - SEE SHEET

ΓΡΑΜΜΗ ΣΥΝΑΡΜΟΓΗΣ -

ΒΛΕΠΕ ΣΧΕΔΙΟ

F-113

F-113

M A

T C

H L

IN

E

S

E E

S H

E E

T Γ Ρ

Α Μ

Μ Η

Σ Υ

Ν Α

Ρ Μ

Ο Γ Η

Σ

Β Λ

Ε Π

Ε Σ

Χ Ε

Δ

ΙΟ

F -1

F -1

M A

T C

H L

IN

E

S

E E

S H

E E

T Γ Ρ

Α Μ

Μ Η

Σ Υ

Ν Α

Ρ Μ

Ο Γ Η

Σ

Β Λ

Ε Π

Ε Σ

Χ Ε

Δ

ΙΟ

F -1

F -1

108 9 11 12 13 14

G

H

K

J

12.5

12.3 12.4

G.7

10.5

CF

CG

CH

H.5

J.5

SPEC CAT

GATE 3

SPEC CAT CORR

LOST & FOUND

BAGGAGE CLAIM

STAIR 2

131 BAGGAGE

BREAKDOWN

BAGGAGE

BUILDUP

SPEC CAT RR

SPRINKLER HAZARD CLASSIFICATION

ΚΑΤΑΤΑΞΗ ΚΙΝΔΥΝΟΥΚΑΤΑΙΟΝΗΤΗΡΑ

LIGHT HAZARD

ΕΛΑΦΡΥΣ ΚΙΝΔΥΝΟΣ

ORDINARY HAZARD

ΣΥΝΗΘΗΣ ΚΙΝΔΥΝΟΣ

SPECIAL OCCUPANCY WAREHOUSE, MISC STORAGE

UP TO 3.66 M ABOVE THE FLOOR

ΕΙΔΙΚΗΣ ΠΑΡΟΥΣΙΑΣ ΑΤΟΜΩΝ ΑΠΟΘΗΚΗ, ΑΠΟΘΗΚΗ

ΔΙΑΦΟΡΩΝ ΕΙΔΩΝ ΕΩΣ ΤΟΥ 3.66 Μ ΠΑΝΩ

ΑΠΟ ΤΟ ΔΑΠΕΔΟ

SM

B

1 5 8 14 16

CA

CB

CE

CH

CG

B

C

K

G

D

C

B

1 2 3 4 5

1568016

DWG

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.

SCALE:

N62470-23-C-XXXX

RICHARD L STEPHENS, P.E.

LMM/MWL

CHIEF ENG/ARCH

DES DRW CHK

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

TI

O N

D A

TE

A

P P

R

S O

U D

A B

A Y

SHEET KEYED NOTES:

ΠΑΡΑΤΗΡΗΣΕΙΣ ΣΧΕΔΙΟΥ:

GENERAL NOTES:

ΓΕΝΙΚΕΣ ΠΑΡΑΤΗΡΗΣΕΙΣ:

A KEYPLAN:

ΣΧΕΔΙΟ ΚΛΕΙΔΙ:

DRAWFORM REVISION: 25 AUGUST 2020

1 2 3 4 5

D

C

B

A

UNCLASSIFIED

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

A T

L A

N T

IC

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

N O

R F

O L K

V

A L A

N T

C A

P

IT

A L I M

P R

O V

E M

E N

T S

BRANCH MANAGER

PM/DM

SATISFACTORY TO DATE

FIRE PROTECTION DPS (DOUG STULTZ)

DPS (DOUG STULTZ)

/3

/2

:1 :0

A

M d c v s

\F

E D

P R

J \6

\F ir e

P ro te c ti o n \P

-1

-F

P

R

.r v t

03/31/2023

F-112

CLO WPS BVP

P J

O

IN

T M

O B

IL

IT

Y P

R O

C E

S S

IN

G

F A

C

IL

IT

Y

S O

U D

A B

A Y

G

R E

E C

E

F L

O O

R P

L A

N

L E

V E

L

S

E C

T O

R B

14068635

F -1

Κ Α

Τ Ο

Ψ Η

Ε

Π

ΙΠ

Ε Δ

Ο

Τ Ο

Μ Ε

Α Σ

Β

1 : 100

FLOOR PLAN - LEVEL 1 - SECTOR B

ΚΑΤΟΨΗ - ΕΠΙΠΕΔΟ 1 - ΤΟΜΕΑΣ Β

0 5000 10000

MILLIMETRESSCALE 1:100

30001000

1. FIRE DEPARTMENT HOSE CONNECTION, 65mm x 25mm REDUCER.

ΣΥΝΔΕΣΗ ΜΑΝΙΚΑΣ ΤΗΣ ΠΥΡΟΣΒΕΣΤΙΚΗΣ ΥΠΗΡΕΣΙΑΣ,

65mm x 25mm ΜΕΙΩΤΗΡΑΣ.

2. SPRINKLER RISER UP TO LEVEL 2, SEE DRAWING F-122

ΚΑΤΑΚΟΡΥΦΟΣ ΚΑΤΑΙΟΝΗΤΗΡΩΝ ΠΑΝΩ ΕΩΣ ΤΟ ΕΠΙΠΕΔΟ 2,

ΔΕΣ ΣΧΕΔΙΟ F-122.

3. FIRE STAND PIPE UP TO LEVEL 2 SEE DRAWING F-122

ΣΩΛΗΝΑΣ ΣΤΑΘΕΡΗΣ ΠΙΕΣΗΣ ΠΥΡΟΣΒΕΣΗΣ ΕΩΣ ΤΟ ΕΠΙΠΕΔΟ 2,

ΔΕΣ ΣΧΕΔΙΟ F-122.

4. PROVIDE UPRIGHT SPRINKLER HEAD WITH HEAD GUARD

UNDER STAIR LANDING.

ΠΡΟΜΗΘΕΥΣΤΕ ΚΑΘΕΤΗ ΚΕΦΑΛΗ ΚΑΤΑΙΟΝΗΤΗΡΑ

ΜΕ ΠΡΟΣΤΑΤΕΥΤΙΚΟ ΚΕΦΑΛΗΣ ΠΑΝΩ ΑΠΟ ΤΟ ΠΛΑΤΥΣΚΑΛΟ.

5. SEISMIC FITTING. SEE DETAIL A1/F-508.

ΣΕΙΣΜΙΚΟ ΕΞΑΡΤΗΜΑ. ΔΕΣ ΛΕΠΤΟΜΕΡΕΙΑ A1/F-508.

PLAN NORTH

A. REFER TO DRAWING F-001 FOR LEGEND, ABBREVIATIONS AND

FIRE SPRINKLER NOTES.

ΑΝΑΤΡΕΞΤΕ ΣΤΟ ΣΧΕΔΙΟ F-001 ΓΙΑ ΤΑ ΥΠΟΜΝΗΜΑΤΑ, ΤΙΣ

ΣΥΝΤΟΜΟΓΡΑΦΙΕΣ ΚΑΙ ΤΙΣ ΠΑΡΑΤΗΡΗΣΕΙΣ ΤΩΝ ΚΑΤΑΙΟΝΗΤΗΡΩΝ

ΠΥΡΚΑΓΙΑΣ.

B. REFER TO LIFE SAFETY PLANS FOR LOCATIONS OF FIRE RATED

WALLS.

ΑΝΑΤΡΕΞΤΕ ΣΤΑ ΣΧΕΔΙΑ ΠΑΘΗΤΙΚΗΣ ΠΥΡΟΠΡΟΣΤΑΣΙΑΣ ΓΙΑ ΤΙΣ

ΘΕΣΕΙΣ ΤΩΝ ΔΙΑΒΑΘΜΙΣΜΕΝΩΝ ΤΟΙΧΩΜΑΤΩΝ ΠΥΡΚΑΓΙΑΣ.

C. PENETRATION OF WALL OR FLOORS MUST BE SEALED.

ΟΙ ΔΙΑΤΡΗΣΕΙΣ ΣΤΑ ΔΑΠΕΔΑ ΚΑΙ ΤΟΥΣ ΤΟΙΧΟΥΣ ΠΡΕΠΕΙ ΝΑ

ΣΦΡΑΓΙΖΟΝΤΑΙ ΚΑΤΑΛΛΗΛΩΣ. ΔΕΙΤΕ ΤΙΣ

ΛΕΠΤΟΜΕΡΕΙΕΣ C1/F-503 ΚΑΙ C4/F503.

D. SEISMIC BRACING IS REQUIRED. SEISMIC BRACING MUST BE

PROVIDED PER NFPA 13 AND DETAILS B1/F-505.

ΣΕΙΣΜΙΚΗ ΣΤΗΡΙΞΗ ΑΠΑΙΤΕΙΤΑΙ. Η ΣΕΙΣΜΙΚΗ ΣΤΗΡΙΞΗ ΠΡΕΠΕΙ ΝΑ

ΕΓΚΑΤΑΣΤΑΘΕΙ ΣΥΜΦΩΝΑ ΜΕ ΤΟΝ NFPA 13

ΚΑΙ ΤΙΣ ΛΕΠΤΟΜΕΡΕΙΕΣ B1/F-505.

1:100

APPROVED BY: PAM COWDEN, P.E.

Tectonic Copyright 2007 ectonic Cop yright 2007

Tectonic Copyright 2007

MATCHLINE - SEE SHEET

ΓΡΑΜΜΗ ΣΥΝΑΡΜΟΓΗΣ -

ΒΛΕΠΕ ΣΧΕΔΙΟ

F-112

F-112

M A

T C

H L

IN

E

S

E E

S H

E E

T Γ Ρ

Α Μ

Μ Η

Σ Υ

Ν Α

Ρ Μ

Ο Γ Η

Σ

Β Λ

Ε Π

Ε Σ

Χ Ε

Δ

ΙΟ

F -1

F -1

M A

T C

H L

IN

E

S

E E

S H

E E

T Γ Ρ

Α Μ

Μ Η

Σ Υ

Ν Α

Ρ Μ

Ο Γ Η

Σ

Β Λ

Ε Π

Ε Σ

Χ Ε

Δ

ΙΟ

F -1

F -1

A1

F-302

108 9 11 12 13 14

B

C

D

E

F

G

12.5

12.3

A

CB

CC

CD

CE

CF

VEST

PAX

102 FUNDS

COMM

JAN

SECURITY

CUSTOMS AND

IMMIGRATION

CUSTOMS OFC

BAGGAGE

BUILDUP

AG OFC

LOBBY

LOBBY

SPRINKLER HAZARD CLASSIFICATION

ΚΑΤΑΤΑΞΗ ΚΙΝΔΥΝΟΥΚΑΤΑΙΟΝΗΤΗΡΑ

LIGHT HAZARD

ΕΛΑΦΡΥΣ ΚΙΝΔΥΝΟΣ

ORDINARY HAZARD

ΣΥΝΗΘΗΣ ΚΙΝΔΥΝΟΣ

SPECIAL OCCUPANCY WAREHOUSE, MISC STORAGE

UP TO 3.66 M ABOVE THE FLOOR

ΕΙΔΙΚΗΣ ΠΑΡΟΥΣΙΑΣ ΑΤΟΜΩΝ ΑΠΟΘΗΚΗ, ΑΠΟΘΗΚΗ

ΔΙΑΦΟΡΩΝ ΕΙΔΩΝ ΕΩΣ ΤΟΥ 3.66 Μ ΠΑΝΩ

ΑΠΟ ΤΟ ΔΑΠΕΔΟ

SM

C

1 5 8 14 16

CA

CB

CE

CH

CG

B

C

K

G

D

C

B

1 2 3 4 5

1568016

DWG

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.

SCALE:

N62470-23-C-XXXX

RICHARD L STEPHENS, P.E.

LMM/MWL

CHIEF ENG/ARCH

DES DRW CHK

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

TI

O N

D A

TE

A

P P

R

S O

U D

A B

A Y

SHEET KEYED NOTES:

ΠΑΡΑΤΗΡΗΣΕΙΣ ΣΧΕΔΙΟΥ:

GENERAL NOTES:

ΓΕΝΙΚΕΣ ΠΑΡΑΤΗΡΗΣΕΙΣ:

A KEYPLAN:

ΣΧΕΔΙΟ ΚΛΕΙΔΙ:

DRAWFORM REVISION: 25 AUGUST 2020

1 2 3 4 5

D

C

B

A

UNCLASSIFIED

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

A T

L A

N T

IC

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

N O

R F

O L K

V

A L A

N T

C A

P

IT

A L I M

P R

O V

E M

E N

T S

BRANCH MANAGER

PM/DM

SATISFACTORY TO DATE

FIRE PROTECTION DPS (DOUG STULTZ)

DPS (DOUG STULTZ)

/3

/2

:1 :0

A

M d c v s

\F

E D

P R

J \6

\F ir e

P ro te c ti o n \P

-1

-F

P

R

.r v t

03/31/2023

F-113

CLO WPS BVP

P J

O

IN

T M

O B

IL

IT

Y P

R O

C E

S S

IN

G

F A

C

IL

IT

Y

S O

U D

A B

A Y

G

R E

E C

E

F L

O O

R P

L A

N

L E

V E

L

S

E C

T O

R C

14068636

F -1

Κ Α

Τ Ο

Ψ Η

Ε

Π

ΙΠ

Ε Δ

Ο

Τ Ο

Μ Ε

Α Σ

C

1 : 100

FLOOR PLAN - LEVEL 1 - SECTOR C

ΚΑΤΟΨΗ - ΕΠΙΠΕΔΟ 1 - ΤΟΜΕΑΣ C

0 5000 10000

MILLIMETRESSCALE 1:100

30001000

1. FIRE DEPARTMENT VALVE 65 mm x 25 mm REDUCER IN

SEMI-RECESSED VALVE CABINET. SEE DETAIL A4/F-504.

ΒΑΝΑ ΣΥΝΔΕΣΗΣ ΤΗΣ ΠΥΡΟΣΒΕΣΤΙΚΗΣ ΥΠΗΡΕΣΙΑΣ

65 mm x 25 mm ΜΕΙΩΤΗΡΑΣ ΕΝΤΟΣ ΗΜΙΧΑΝΤΡΩΜΕΝΟΥ

ΝΤΟΥΛΑΠΙΟΥ. ΔΕΣ ΛΕΠΤΟΜΕΡΕΙΑ A4/F-504.

2. EXPOSED SPRINKLER PIPING IN LOBBY AREA AT ROOF.

ΕΚΤΕΘΕΙΜΕΝΗ ΣΩΛΗΝΑ ΚΑΤΑΙΟΝΗΤΗΡΩΝ ΜΕΣΑ ΣΤΗΝ ΠΕΡΙΟΧΗ

ΑΝΑΜΟΝΗΣ ΣΤΗΝ ΣΚΕΠΗ.

PLAN NORTH

A. REFER TO DRAWING F-001 FOR LEGEND, ABBREVIATIONS AND

FIRE SPRINKLER NOTES.

ΑΝΑΤΡΕΞΤΕ ΣΤΟ ΣΧΕΔΙΟ F-001 ΓΙΑ ΤΑ ΥΠΟΜΝΗΜΑΤΑ, ΤΙΣ

ΣΥΝΤΟΜΟΓΡΑΦΙΕΣ ΚΑΙ ΤΙΣ ΠΑΡΑΤΗΡΗΣΕΙΣ ΤΩΝ ΚΑΤΑΙΟΝΗΤΗΡΩΝ

ΠΥΡΚΑΓΙΑΣ.

B. REFER TO LIFE SAFETY PLANS FOR LOCATIONS OF FIRE RATED

WALLS.

ΑΝΑΤΡΕΞΤΕ ΣΤΑ ΣΧΕΔΙΑ ΠΑΘΗΤΙΚΗΣ ΠΥΡΟΠΡΟΣΤΑΣΙΑΣ ΓΙΑ ΤΙΣ

ΘΕΣΕΙΣ ΤΩΝ ΔΙΑΒΑΘΜΙΣΜΕΝΩΝ ΤΟΙΧΩΜΑΤΩΝ ΠΥΡΚΑΓΙΑΣ.

C. PENETRATION OF WALL OR FLOORS MUST BE SEALED.

SEE DETAILS C1/F-503 AND C4/F503.

ΟΙ ΔΙΑΤΗΣΕΙΣ ΣΤΑ ΔΑΠΕΔΑ ΚΑΙ ΤΟΥΣ ΤΟΙΧΟΥΣ ΠΡΕΠΕΙ ΝΑ

ΣΦΡΑΓΙΖΟΝΤΑΙ ΚΑΤΑΛΛΗΛΩΣ. ΔΕΙΤΕ ΤΙΣ

ΛΕΠΤΟΜΕΡΕΙΕΣ C1/F-503 ΚΑΙ C4/F503.

D. SEISMIC BRACING IS REQUIRED. SEISMIC BRACING MUST BE

PROVIDED PER NFPA 13 AND DETAILS B1/F-505.

ΣΕΙΣΜΙΚΗ ΣΤΗΡΙΞΗ ΑΠΑΙΤΕΙΤΑΙ. Η ΣΕΙΣΜΙΚΗ ΣΤΗΡΙΞΗ ΠΡΕΠΕΙ ΝΑ

ΕΓΚΑΤΑΣΤΑΘΕΙ ΣΥΜΦΩΝΑ ΜΕ ΤΟΝ NFPA 13

ΚΑΙ ΤΙΣ ΛΕΠΤΟΜΕΡΕΙΕΣ B1/F-505.

E. REFER TO ARCHITECTURAL CEILING PLANS FOR TYPES OF CEILINGS.

ΑΝΑΤΡΕΞΤΕ ΣΤΙΣ ΑΡΧΙΤΕΚΤΟΝΙΚΕΣ ΚΑΤΟΨΕΙΣ ΤΩΝ ΟΡΟΦΩΝ

ΓΙΑ ΤΟΥΣ ΤΥΠΟΥΣ ΤΩΝ ΟΡΟΦΩΝ.

1:100

APPROVED BY: PAM COWDEN, P.E.

Tectonic Copyright 2007 ectonic Cop yright 2007

Tectonic Copyright 2007

T ectonic Cop yright 2007

T ectonic Cop yright 2007

T ectonic Cop yright 2007

T ectonic Cop yright 2007

Tectonic Copyright 2007

T ectonic Cop yright 2007

Tectonic Copyright 2007

T ectonic Cop yright 2007

T ectonic Cop yright 2007

T ectonic Cop yright 2007

T ectonic Cop yright 2007

T ectonic Cop yright 2007

Tectonic Copyright 2007 Tectonic Copyright 2007

T ectonic Cop yright 2007

Tectonic Copyright 2007

T ectonic Cop yright 2007

T ectonic Cop yright 2007

T ectonic Cop yright 2007

T ectonic Cop yright 2007

T ectonic Cop yright 2007

MATCHLINE - SEE SHEET

ΓΡΑΜΜΗ ΣΥΝΑΡΜΟΓΗΣ -

ΒΛΕΠΕ ΣΧΕΔΙΟ

F-111

F-111

M A

T C

H L

IN

E

S

E E

S H

E E

T Γ Ρ

Α Μ

Μ Η

Σ Υ

Ν Α

Ρ Μ

Ο Γ Η

Σ

Β Λ

Ε Π

Ε Σ

Χ Ε

Δ

ΙΟ

F -1

F -1

14 14.4 15 16

B

C

D

E

F

G

14.6

14.814.5

A

14.2

E.3

MECH

PAX

FUNDS

PSC

PAX

ELEC

WOMEN

MEN

RR

MOTHER

FAMILY

COMM

JAN

WOMEN

MEN

CORR

JAN

ELEV RM

STAIR 1

ELEV

CORR

A1

F-303

SPRINKLER HAZARD CLASSIFICATION

ΚΑΤΑΤΑΞΗ ΚΙΝΔΥΝΟΥΚΑΤΑΙΟΝΗΤΗΡΑ

LIGHT HAZARD

ΕΛΑΦΡΥΣ ΚΙΝΔΥΝΟΣ

ORDINARY HAZARD

ΣΥΝΗΘΗΣ ΚΙΝΔΥΝΟΣ

SPECIAL OCCUPANCY WAREHOUSE, MISC STORAGE

UP TO 3.66 M ABOVE THE FLOOR

ΕΙΔΙΚΗΣ ΠΑΡΟΥΣΙΑΣ ΑΤΟΜΩΝ ΑΠΟΘΗΚΗ, ΑΠΟΘΗΚΗ

ΔΙΑΦΟΡΩΝ ΕΙΔΩΝ ΕΩΣ ΤΟΥ 3.66 Μ ΠΑΝΩ

ΑΠΟ ΤΟ ΔΑΠΕΔΟ

SM

D

1 5 8 14 16

CA

CB

CE

CH

CG

B

C

K

G

D

C

B

1 2 3 4 5

1568016

DWG

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.

SCALE:

N62470-23-C-XXXX

RICHARD L STEPHENS, P.E.

LMM/MWL

CHIEF ENG/ARCH

DES DRW CHK

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

TI

O N

D A

TE

A

P P

R

S O

U D

A B

A Y

SHEET KEYED NOTES:

ΠΑΡΑΤΗΡΗΣΕΙΣ ΣΧΕΔΙΟΥ:

GENERAL NOTES:

ΓΕΝΙΚΕΣ ΠΑΡΑΤΗΡΗΣΕΙΣ:

A KEYPLAN:

ΣΧΕΔΙΟ ΚΛΕΙΔΙ:

DRAWFORM REVISION: 25 AUGUST 2020

1 2 3 4 5

D

C

B

A

UNCLASSIFIED

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

A T

L A

N T

IC

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

N O

R F

O L K

V

A L A

N T

C A

P

IT

A L I M

P R

O V

E M

E N

T S

BRANCH MANAGER

PM/DM

SATISFACTORY TO DATE

FIRE PROTECTION DPS (DOUG STULTZ)

DPS (DOUG STULTZ)

/3

/2

:1 :0

A

M d c v s

\F

E D

P R

J \6

\F ir e

P ro te c ti o n \P

-1

-F

P

R

.r v t

03/31/2023

F-114

CLO WPS BVP

P J

O

IN

T M

O B

IL

IT

Y P

R O

C E

S S

IN

G

F A

C

IL

IT

Y

S O

U D

A B

A Y

G

R E

E C

E

F L

O O

R P

L A

N

L E

V E

L

S

E C

T O

R D

14068637

F -1

Κ Α

Τ Ο

Ψ Η

Ε

Π

ΙΠ

Ε Δ

Ο

Τ Ο

Μ Ε

Α Σ

D

1 : 100

FLOOR PLAN - LEVEL 1 - SECTOR D

ΚΑΤΟΨΗ - ΕΠΙΠΕΔΟ 1 - ΤΟΜΕΑΣ D

0 5000 10000

MILLIMETRESSCALE 1:100

30001000

1. PROVIDE CONCEALED SPRINKLER HEADS IN LOBBY 101 CEILING.

ΠΡΟΜΗΘΕΥΣΤΕ ΚΕΦΑΛΕΣ ΚΑΤΑΙΟΝΗΤΗΡΩΝ ΚΡΥΦΟΥ ΤΥΠΟΥ ΓΙΑ ΤΗΝ

ΟΡΟΦΗ ΤΗΣ ΑΙΘΟΥΣΑΣ ΑΝΑΜΟΝΗΣ 101.

2. FIRE DEPARTMENT VALVE 65 mm x 25 mm REDUCER AT 915 MM

ABOVE LANDING.

ΒΑΝΑ ΣΥΝΔΕΣΗΣ ΤΗΣ ΠΥΡΟΣΒΕΣΤΙΚΗΣ ΥΠΗΡΕΣΙΑΣ 65 mm x 25 mm

ΜΕΙΩΤΗΡΑΣ ΣΤΑ 915 ΜΜ ΠΑΝΩ ΑΠΟ ΤΟ ΠΛΑΤΥΣΚΑΛΟ.

3. ELEVATOR PIT AND EQUIPMENT ROOM SPRINKLERS. SEE DETAILS

C1 & C3/F-501.

ΚΑΤΑΙΟΝΗΤΗΡΕΣ ΣΚΑΜΜΑΤΟΣ ΑΝΕΛΚΥΣΤΗΡΑ ΚΑΙ ΔΩΜΑΤΙΟΥ

ΕΞΟΠΛΙΣΜΟΥ. ΔΕΣ ΛΕΠΤΟΜΕΡΕΙΕΣ C1 & C3/F-501.

4. INSPECTOR'S TEST/DRAIN PIPING.

ΕΛΕΓΧΟΣ ΕΠΙΘΕΩΡΗΤΗ/ΣΩΛΗΝΑ ΑΠΟΣΤΡΑΓΓΙΣΗΣ.

5. SUPERVISED SHUT-OFF VALVE AND FLOW SWITCH WITH NO TIME

DELAY TO SPRINKLER HEAD. SEE DETAIL C3/F-501.

ΕΠΟΠΤΕΥΟΜΕΝΗ ΒΑΛΒΙΔΑ ΔΙΑΚΟΠΗΣ ΚΑΙ ΔΙΑΚΟΠΤΗΣ ΡΟΗΣ ΧΩΡΙΣ

ΧΡΟΝΙΚΗ ΚΑΘΥΣΤΕΡΙΣΗ ΣΤΗΝ ΚΕΦΑΛΗ ΚΑΤΑΙΟΝΗΤΗΡΑ.

ΔΕΣ ΛΕΠΤΟΜΕΡΕΙΑ C3/F-501.

6. PROVIDE UPRIGHT SPRINKLER HEAD WITH HEAD GUARD

UNDER STAIR LANDING.

ΠΡΟΜΗΘΕΥΣΤΕ ΚΑΘΕΤΗ ΚΕΦΑΛΗ ΚΑΤΑΙΟΝΗΤΗΡΑ

ΜΕ ΠΡΟΣΤΑΤΕΥΤΙΚΟ ΚΕΦΑΛΗΣ ΠΑΝΩ ΑΠΟ ΤΟ ΠΛΑΤΥΣΚΑΛΟ.

7. 65 mm UP TO FIRE DEPARTMENT VALVE.

65mm ΠΑΝΩ ΠΡΟΣ ΤΗΝ ΒΑΝΑ ΣΥΝΔΕΣΗΣ ΤΗΣ ΠΥΡΟΣΒΕΣΤΙΚΗΣ

ΥΠΗΡΕΣΙΑΣ.

PLAN NORTH

A. REFER TO DRAWING F-001 FOR LEGEND, ABBREVIATIONS AND

FIRE SPRINKLER NOTES.

ΑΝΑΤΡΕΞΤΕ ΣΤΟ ΣΧΕΔΙΟ F-001 ΓΙΑ ΤΑ ΥΠΟΜΝΗΜΑΤΑ, ΤΙΣ

ΣΥΝΤΟΜΟΓΡΑΦΙΕΣ ΚΑΙ ΤΙΣ ΠΑΡΑΤΗΡΗΣΕΙΣ ΤΩΝ ΚΑΤΑΙΟΝΗΤΗΡΩΝ

ΠΥΡΚΑΓΙΑΣ.

B. REFER TO LIFE SAFETY PLANS FOR LOCATIONS OF FIRE RATED

WALLS.

ΑΝΑΤΡΕΞΤΕ ΣΤΑ ΣΧΕΔΙΑ ΠΑΘΗΤΙΚΗΣ ΠΥΡΟΠΡΟΣΤΑΣΙΑΣ ΖΩΗΣ ΓΙΑ ΤΙΣ

ΘΕΣΕΙΣ ΤΩΝ ΔΙΑΒΑΘΜΙΣΜΕΝΩΝ ΤΟΙΧΩΜΑΤΩΝ ΠΥΡΚΑΓΙΑΣ.

C. PENETRATION OF WALL OR FLOORS MUST BE SEALED.

SEE DETAILS C1/F-503 AND C4/F503.

ΟΙ ΔΙΑΤΡΗΣΕΙΣ ΣΤΑ ΔΑΠΕΔΑ ΚΑΙ ΤΟΥΣ ΤΟΙΧΟΥΣ ΠΡΕΠΕΙ ΝΑ

ΣΦΡΑΓΙΖΟΝΤΑΙ ΚΑΤΑΛΛΗΛΩΣ. ΔΕΙΤΕ ΤΙΣ

ΛΕΠΤΟΜΕΡΕΙΕΣ C1/F-503 ΚΑΙ C4/F503.

D. SEISMIC BRACING IS REQUIRED. SEISMIC BRACING MUST BE

PROVIDED PER NFPA 13 AND DETAILS B1/F-505.

ΣΕΙΣΜΙΚΗ ΣΤΗΡΙΞΗ ΑΠΑΙΤΕΙΤΑΙ. Η ΣΕΙΣΜΙΚΗ ΣΤΗΡΙΞΗ ΠΡΕΠΕΙ ΝΑ

ΕΓΚΑΤΑΣΤΑΘΕΙ ΣΥΜΦΩΝΑ ΜΕ ΤΟΝ NFPA 13

ΚΑΙ ΤΙΣ ΛΕΠΤΟΜΕΡΕΙΕΣ B1/F-505.

1:100

APPROVED BY: PAM COWDEN, P.E.

T ectonic Cop yright 2007 ectonic Cop yright 2007

MATCHLINE - SEE SHEET

ΓΡΑΜΜΗ ΣΥΝΑΡΜΟΓΗΣ -

ΒΛΕΠΕ ΣΧΕΔΙΟ

F-118

F-118 M

A T

C H

L

IN

E

S E

E S

H E

E T

Γ Ρ

Α Μ

Μ Η

Σ Υ

Ν Α

Ρ Μ

Ο Γ Η

Σ

Β Λ

Ε Π

Ε Σ

Χ Ε

Δ

ΙΟ

F -1

F -1

A1

F-302

7 8 9

E

F

G

H

J

G.7

CE

CF

CG

H.5

5.1 5.9

SUPPLY OFC

DET. MAIN. SPT

OFC

T-LINE

T-LINE OFC

E-28

PARALOFT

BREAK

RR

RR

151RR

CARGO BAY

CARGO BAY

CORR

SPRINKLER HAZARD CLASSIFICATION

ΚΑΤΑΤΑΞΗ ΚΙΝΔΥΝΟΥΚΑΤΑΙΟΝΗΤΗΡΑ

LIGHT HAZARD

ΕΛΑΦΡΥΣ ΚΙΝΔΥΝΟΣ

ORDINARY HAZARD

ΣΥΝΗΘΗΣ ΚΙΝΔΥΝΟΣ

SPECIAL OCCUPANCY WAREHOUSE, MISC STORAGE

UP TO 3.66 M ABOVE THE FLOOR

ΕΙΔΙΚΗΣ ΠΑΡΟΥΣΙΑΣ ΑΤΟΜΩΝ ΑΠΟΘΗΚΗ, ΑΠΟΘΗΚΗ

ΔΙΑΦΟΡΩΝ ΕΙΔΩΝ ΕΩΣ ΤΟΥ 3.66 Μ ΠΑΝΩ

ΑΠΟ ΤΟ ΔΑΠΕΔΟ

SM

E

1 5 8 14 16

CA

CB

CE

CH

CG

B

C

K

G

D

C

B

1 2 3 4 5

1568016

DWG

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.

SCALE:

N62470-23-C-XXXX

RICHARD L STEPHENS, P.E.

LMM/MWL

CHIEF ENG/ARCH

DES DRW CHK

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

TI

O N

D A

TE

A

P P

R

S O

U D

A B

A Y

SHEET KEYED NOTES:

ΠΑΡΑΤΗΡΗΣΕΙΣ ΣΧΕΔΙΟΥ:

GENERAL NOTES:

ΓΕΝΙΚΕΣ ΠΑΡΑΤΗΡΗΣΕΙΣ:

A KEYPLAN:

ΣΧΕΔΙΟ ΚΛΕΙΔΙ:

DRAWFORM REVISION: 25 AUGUST 2020

1 2 3 4 5

D

C

B

A

UNCLASSIFIED

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

A T

L A

N T

IC

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

N O

R F

O L K

V

A L A

N T

C A

P

IT

A L I M

P R

O V

E M

E N

T S

BRANCH MANAGER

PM/DM

SATISFACTORY TO DATE

FIRE PROTECTION DPS (DOUG STULTZ)

DPS (DOUG STULTZ)

/3

/2

:1 :0

A

M d c v s

\F

E D

P R

J \6

\F ir e

P ro te c ti o n \P

-1

-F

P

R

.r v t

03/31/2023

F-115

CLO WPS BVP

P J

O

IN

T M

O B

IL

IT

Y P

R O

C E

S S

IN

G

F A

C

IL

IT

Y

S O

U D

A B

A Y

G

R E

E C

E

F L

O O

R P

L A

N

L E

V E

L

S

E C

T O

R E

14068638

F -1

Κ Α

Τ Ο

Ψ Η

Ε

Π

ΙΠ

Ε Δ

Ο

Τ Ο

Μ Ε

Α Σ

Ε

1 : 100

FLOOR PLAN - LEVEL 1 - SECTOR E

ΚΑΤΟΨΗ - ΕΠΙΠΕΔΟ 1 - ΤΟΜΕΑΣ Ε

0 5000 10000

MILLIMETRESSCALE 1:100

30001000

1. FORKLIFT AND CARGO PATH.

ΔΙΑΔΡΟΜΕΣ ΠΕΡΟΝΟΦΟΡΟΥ ΑΝΥΨΩΤΙΚΟΥ ΚΑΙ ΕΜΠΟΡΕΥΜΑΤΩΝ.

2. FIRE SPRINKLER MAIN.

ΚΥΡΙΑ ΣΩΛΗΝΑ ΚΑΤΑΙΟΝΗΤΗΡΩΝ ΠΥΡΟΣΒΕΣΗΣ.

3. FIRE STANDPIPE.

ΣΩΛΗΝΑ ΣΤΑΘΕΡΗΣ ΠΙΕΣΗΣ ΠΥΡΟΣΒΕΣΗΣ.

4. MNS LOCAL OPERATING CONSOLE.

ΤΟΠΙΚΗ ΚΟΣΝΟΛΑ ΛΕΙΤΟΥΡΓΙΑΣ MNS.

5. SEISMIC FITTING. SEE DETAIL A1/F-508.

ΣΕΙΣΜΙΚΟ ΕΞΑΡΤΗΜΑ. ΔΕΣ ΛΕΠΤΟΜΕΡΕΙΑ A1/F-508.

PLAN NORTH

A. REFER TO DRAWING F-001 FOR LEGEND, ABBREVIATIONS AND

FIRE SPRINKLER NOTES.

ΑΝΑΤΡΕΞΤΕ ΣΤΟ ΣΧΕΔΙΟ F-001 ΓΙΑ ΤΑ ΥΠΟΜΝΗΜΑΤΑ, ΤΙΣ

ΣΥΝΤΟΜΟΓΡΑΦΙΕΣ ΚΑΙ ΤΙΣ ΠΑΡΑΤΗΡΗΣΕΙΣ ΤΩΝ ΚΑΤΑΙΟΝΗΤΗΡΩΝ

ΠΥΡΚΑΓΙΑΣ.

B. REFER TO LIFE SAFETY PLANS FOR LOCATIONS OF FIRE RATED

WALLS.

ΑΝΑΤΡΕΞΤΕ ΣΤΑ ΣΧΕΔΙΑ ΠΑΘΗΤΙΚΗΣ ΠΥΡΟΠΡΟΣΤΑΣΙΑΣ ΓΙΑ ΤΙΣ

ΘΕΣΕΙΣ ΤΩΝ ΔΙΑΒΑΘΜΙΣΜΕΝΩΝ ΤΟΙΧΩΜΑΤΩΝ ΠΥΡΚΑΓΙΑΣ.

C. PENETRATION OF WALL OR FLOORS MUST BE SEALED.

SEE DETAILS C1/F-503 AND C4/F503.

ΟΙ ΔΙΑΤΡΗΣΕΙΣ ΣΤΑ ΔΑΠΕΔΑ ΚΑΙ ΤΟΥΣ ΤΟΙΧΟΥΣ ΠΡΕΠΕΙ ΝΑ

ΣΦΡΑΓΙΖΟΝΤΑΙ ΚΑΤΑΛΛΗΛΩΣ. ΔΕΙΤΕ ΤΙΣ

ΛΕΠΤΟΜΕΡΕΙΕΣ C1/F-503 ΚΑΙ C4/F503.

D. SEISMIC BRACING IS REQUIRED. SEISMIC BRACING MUST BE

PROVIDED PER NFPA 13 AND DETAILS B1/F-505.

ΣΕΙΣΜΙΚΗ ΣΤΗΡΙΞΗ ΑΠΑΙΤΕΙΤΑΙ. ΤΟΠΟΘΕΤΗΣΤΕ ΣΕΙΣΜΙΚΗ ΣΤΗΡΙΞΗ

ΣΥΜΦΩΝΑ ΜΕ ΤΟΝ NFPA 13 ΚΑΙ ΤΙΣ ΛΕΠΤΟΜΕΡΕΙΕΣ B1/F-503.

1:100

APPROVED BY: PAM COWDEN, P.E.

MATCHLINE - SEE SHEET

ΓΡΑΜΜΗ ΣΥΝΑΡΜΟΓΗΣ -

ΒΛΕΠΕ ΣΧΕΔΙΟ

F-117

F-117

M A

T C

H L

IN

E

S

E E

S H

E E

T Γ Ρ

Α Μ

Μ Η

Σ Υ

Ν Α

Ρ Μ

Ο Γ Η

Σ

Β Λ

Ε Π

Ε Σ

Χ Ε

Δ

ΙΟ

F -1

F -1

1 2 4

CE

CF

CG

CH

5.1

CARGO BAY

SPRINKLER HAZARD CLASSIFICATION

ΚΑΤΑΤΑΞΗ ΚΙΝΔΥΝΟΥΚΑΤΑΙΟΝΗΤΗΡΑ

LIGHT HAZARD

ΕΛΑΦΡΥΣ ΚΙΝΔΥΝΟΣ

ORDINARY HAZARD

ΣΥΝΗΘΗΣ ΚΙΝΔΥΝΟΣ

SPECIAL OCCUPANCY WAREHOUSE, MISC STORAGE

UP TO 3.66 M ABOVE THE FLOOR

ΕΙΔΙΚΗΣ ΠΑΡΟΥΣΙΑΣ ΑΤΟΜΩΝ ΑΠΟΘΗΚΗ, ΑΠΟΘΗΚΗ

ΔΙΑΦΟΡΩΝ ΕΙΔΩΝ ΕΩΣ ΤΟΥ 3.66 Μ ΠΑΝΩ

ΑΠΟ ΤΟ ΔΑΠΕΔΟ

SM

F

1 5 8 14 16

CA

CB

CE

CH

CG

B

C

K

G

D

C

B

1 2 3 4 5

1568016

DWG

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.

SCALE:

N62470-23-C-XXXX

RICHARD L STEPHENS, P.E.

LMM/MWL

CHIEF ENG/ARCH

DES DRW CHK

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

TI

O N

D A

TE

A

P P

R

S O

U D

A B

A Y

SHEET KEYED NOTES:

ΠΑΡΑΤΗΡΗΣΕΙΣ ΣΧΕΔΙΟΥ:

GENERAL NOTES:

ΓΕΝΙΚΕΣ ΠΑΡΑΤΗΡΗΣΕΙΣ:

A KEYPLAN:

ΣΧΕΔΙΟ ΚΛΕΙΔΙ:

DRAWFORM REVISION: 25 AUGUST 2020

1 2 3 4 5

D

C

B

A

UNCLASSIFIED

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

A T

L A

N T

IC

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

N O

R F

O L K

V

A L A

N T

C A

P

IT

A L I M

P R

O V

E M

E N

T S

BRANCH MANAGER

PM/DM

SATISFACTORY TO DATE

FIRE PROTECTION DPS (DOUG STULTZ)

DPS (DOUG STULTZ)

/3

/2

:1 :0

A

M d c v s

\F

E D

P R

J \6

\F ir e

P ro te c ti o n \P

-1

-F

P

R

.r v t

03/31/2023

F-116

CLO WPS BVP

P J

O

IN

T M

O B

IL

IT

Y P

R O

C E

S S

IN

G

F A

C

IL

IT

Y

S O

U D

A B

A Y

G

R E

E C

E

F L

O O

R P

L A

N

L E

V E

L

S

E C

T O

R F

14068639

F -1

Κ Α

Τ Ο

Ψ Η

Ε

Π

ΙΠ

Ε Δ

Ο

Τ Ο

Μ Ε

Α Σ

F

1 : 100

FLOOR PLAN - LEVEL 1 - SECTOR F

ΚΑΤΟΨΗ - ΕΠΙΠΕΔΟ 1 - ΤΟΜΕΑΣ F

0 5000 10000

MILLIMETRESSCALE 1:100

30001000

1. FIRE SPRINKLER MAIN.

ΚΥΡΙΑ ΣΩΛΗΝΑ ΚΑΤΑΙΟΝΗΤΗΡΩΝ ΠΥΡΟΣΒΕΣΗΣ.

2. FORK LIFT PATH.

ΔΙΑΔΡΟΜΗ ΠΕΡΟΝΟΦΟΡΟΥ ΑΝΥΨΩΤΙΚΟΥ.

PLAN NORTH

A. REFER TO DRAWING F-001 FOR LEGEND, ABBREVIATIONS AND

FIRE SPRINKLER NOTES.

ΑΝΑΤΡΕΞΤΕ ΣΤΟ ΣΧΕΔΙΟ F-001 ΓΙΑ ΤΑ ΥΠΟΜΝΗΜΑΤΑ, ΤΙΣ

ΣΥΝΤΟΜΟΓΡΑΦΙΕΣ ΚΑΙ ΤΙΣ ΠΑΡΑΤΗΡΗΣΕΙΣ ΤΩΝ ΚΑΤΑΙΟΝΗΤΗΡΩΝ

ΠΥΡΚΑΓΙΑΣ.

B. REFER TO LIFE SAFETY PLANS FOR LOCATIONS OF FIRE RATED

WALLS.

ΑΝΑΤΡΕΞΤΕ ΣΤΑ ΣΧΕΔΙΑ ΠΑΘΗΤΙΚΗΣ ΠΥΡΟΠΡΟΣΤΑΣΙΑΣ ΓΙΑ ΤΙΣ ΘΕΣΕΙΣ

ΤΩΝ ΔΙΑΒΑΘΜΙΣΜΕΝΩΝ ΤΟΙΧΩΜΑΤΩΝ ΠΥΡΚΑΓΙΑΣ.

C. PENETRATION OF WALL OR FLOORS MUST BE SEALED.

SEE DETAILS C1/F-503 AND C4/F503.

ΟΙ ΔΙΑΤΡΗΣΕΙΣ ΣΤΑ ΔΑΠΕΔΑ ΚΑΙ ΤΟΥΣ ΤΟΙΧΟΥΣ ΠΡΕΠΕΙ ΝΑ

ΣΦΡΑΓΙΖΟΝΤΑΙ ΚΑΤΑΛΛΗΛΩΣ. ΔΕΙΤΕ ΤΙΣ

ΛΕΠΤΟΜΕΡΕΙΕΣ C1/F-503 ΚΑΙ C4/F503.

D. SEISMIC BRACING IS REQUIRED. SEISMIC BRACING MUST BE

PROVIDED PER NFPA 13 AND DETAILS B1/F-505.

ΣΕΙΣΜΙΚΗ ΣΤΗΡΙΞΗ ΑΠΑΙΤΕΙΤΑΙ. ΤΟΠΟΘΕΤΗΣΤΕ ΣΕΙΣΜΙΚΗ ΣΤΗΡΙΞΗ

ΣΥΜΦΩΝΑ ΜΕ ΤΟΝ NFPA 13 ΚΑΙ ΤΙΣ ΛΕΠΤΟΜΕΡΕΙΕΣ B1/F-503.

1:100

APPROVED BY: PAM COWDEN, P.E.

MATCHLINE - SEE SHEET

ΓΡΑΜΜΗ ΣΥΝΑΡΜΟΓΗΣ -

ΒΛΕΠΕ ΣΧΕΔΙΟ

F-116

F-116

M A

T C

H L

IN

E

S

E E

S H

E E

T Γ Ρ

Α Μ

Μ Η

Σ Υ

Ν Α

Ρ Μ

Ο Γ Η

Σ

Β Λ

Ε Π

Ε Σ

Χ Ε

Δ

ΙΟ

F -1

F -1

1 2 3 4 5

CA

CB

CC

CD

STORAGE

CARGO BAY

SPRINKLER HAZARD CLASSIFICATION

ΚΑΤΑΤΑΞΗ ΚΙΝΔΥΝΟΥΚΑΤΑΙΟΝΗΤΗΡΑ

LIGHT HAZARD

ΕΛΑΦΡΥΣ ΚΙΝΔΥΝΟΣ

ORDINARY HAZARD

ΣΥΝΗΘΗΣ ΚΙΝΔΥΝΟΣ

SPECIAL OCCUPANCY WAREHOUSE, MISC STORAGE

UP TO 3.66 M ABOVE THE FLOOR

ΕΙΔΙΚΗΣ ΠΑΡΟΥΣΙΑΣ ΑΤΟΜΩΝ ΑΠΟΘΗΚΗ, ΑΠΟΘΗΚΗ

ΔΙΑΦΟΡΩΝ ΕΙΔΩΝ ΕΩΣ ΤΟΥ 3.66 Μ ΠΑΝΩ

ΑΠΟ ΤΟ ΔΑΠΕΔΟ

SM

G

1 5 8 14 16

CA

CB

CE

CH

CG

B

C

K

G

D

C

B

1 2 3 4 5

1568016

DWG

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.

SCALE:

N62470-23-C-XXXX

RICHARD L STEPHENS, P.E.

LMM/MWL

CHIEF ENG/ARCH

DES DRW CHK

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

TI

O N

D A

TE

A

P P

R

S O

U D

A B

A Y

SHEET KEYED NOTES:

ΠΑΡΑΤΗΡΗΣΕΙΣ ΣΧΕΔΙΟΥ:

GENERAL NOTES:

ΓΕΝΙΚΕΣ ΠΑΡΑΤΗΡΗΣΕΙΣ:

A KEYPLAN:

ΣΧΕΔΙΟ ΚΛΕΙΔΙ:

DRAWFORM REVISION: 25 AUGUST 2020

1 2 3 4 5

D

C

B

A

UNCLASSIFIED

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

A T

L A

N T

IC

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

N O

R F

O L K

V

A L A

N T

C A

P

IT

A L I M

P R

O V

E M

E N

T S

BRANCH MANAGER

PM/DM

SATISFACTORY TO DATE

FIRE PROTECTION DPS (DOUG STULTZ)

DPS (DOUG STULTZ)

/3

/2

:1 :0

A

M d c v s

\F

E D

P R

J \6

\F ir e

P ro te c ti o n \P

-1

-F

P

R

.r v t

03/31/2023

F-117

CLO WPS BVP

P J

O

IN

T M

O B

IL

IT

Y P

R O

C E

S S

IN

G

F A

C

IL

IT

Y

S O

U D

A B

A Y

G

R E

E C

E

F L

O O

R P

L A

N

L E

V E

L

S

E C

T O

R G

14068640

F -1

Κ Α

Τ Ο

Ψ Η

Ε

Π

ΙΠ

Ε Δ

Ο

Τ Ο

Μ Ε

Α Σ

G

1 : 100

FLOOR PLAN - LEVEL 1 - SECTOR G

ΚΑΤΟΨΗ - ΕΠΙΠΕΔΟ 1 - ΤΟΜΕΑΣ G

0 5000 10000

MILLIMETRESSCALE 1:100

30001000

1. FORK LIFT AND CARGO PATHS.

ΔΙΑΔΡΟΜΕΣ ΠΕΡΟΝΟΦΟΡΟΥ ΑΝΥΨΩΤΙΚΟΥ ΚΑΙ ΕΜΠΟΡΕΥΜΑΤΩΝ.

2. FIRE SPRINKLER MAIN.

ΚΥΡΙΑ ΣΩΛΗΝΑ ΚΑΤΑΙΟΝΗΤΗΡΩΝ ΠΥΡΟΣΒΕΣΗΣ.

PLAN NORTH

A. REFER TO DRAWING F-001 FOR LEGEND, ABBREVIATIONS AND

FIRE SPRINKLER NOTES.

ΑΝΑΤΡΕΞΤΕ ΣΤΟ ΣΧΕΔΙΟ F-001 ΓΙΑ ΤΑ ΥΠΟΜΝΗΜΑΤΑ, ΤΙΣ

ΣΥΝΤΟΜΟΓΡΑΦΙΕΣ ΚΑΙ ΤΙΣ ΠΑΡΑΤΗΡΗΣΕΙΣ ΤΩΝ ΚΑΤΑΙΟΝΗΤΗΡΩΝ

ΠΥΡΚΑΓΙΑΣ.

B. REFER TO LIFE SAFETY PLANS FOR LOCATIONS OF FIRE RATED

WALLS.

ΑΝΑΤΡΕΞΤΕ ΣΤΑ ΣΧΕΔΙΑ ΠΑΘΗΤΙΚΗΣ ΠΥΡΟΠΡΟΣΤΑΣΙΑΣ ΓΙΑ ΤΙΣ ΘΕΣΕΙΣ

ΤΩΝ ΔΙΑΒΑΘΜΙΣΜΕΝΩΝ ΤΟΙΧΩΜΑΤΩΝ ΠΥΡΚΑΓΙΑΣ.

C. PENETRATION OF WALL OR FLOORS MUST BE SEALED.

SEE DETAILS C1/F-503 AND C4/F503.

ΟΙ ΔΙΑΤΡΗΣΕΙΣ ΣΤΑ ΔΑΠΕΔΑ ΚΑΙ ΤΟΥΣ ΤΟΙΧΟΥΣ ΠΡΕΠΕΙ ΝΑ

ΣΦΡΑΓΙΖΟΝΤΑΙ ΚΑΤΑΛΛΗΛΩΣ. ΔΕΙΤΕ ΤΙΣ

ΛΕΠΤΟΜΕΡΕΙΕΣ C1/F-503 ΚΑΙ C4/F503.

D. SEISMIC BRACING IS REQUIRED. SEISMIC BRACING MUST BE

PROVIDED PER NFPA 13 AND DETAILS B1/F-505.

ΣΕΙΣΜΙΚΗ ΣΤΗΡΙΞΗ ΑΠΑΙΤΕΙΤΑΙ. Η ΣΕΙΣΜΙΚΗ ΣΤΗΡΙΞΗ ΠΡΕΠΕΙ ΝΑ

ΕΓΚΑΤΑΣΤΑΘΕΙ ΣΥΜΦΩΝΑ ΜΕ ΤΟΝ NFPA 13

ΚΑΙ ΤΙΣ ΛΕΠΤΟΜΕΡΕΙΕΣ B1/F-505.

1:100

APPROVED BY: PAM COWDEN, P.E.

SPRINKLER HAZARD CLASSIFICATION

ΚΑΤΑΤΑΞΗ ΚΙΝΔΥΝΟΥΚΑΤΑΙΟΝΗΤΗΡΑ

LIGHT HAZARD

ΕΛΑΦΡΥΣ ΚΙΝΔΥΝΟΣ

ORDINARY HAZARD

ΣΥΝΗΘΗΣ ΚΙΝΔΥΝΟΣ

SPECIAL OCCUPANCY WAREHOUSE, MISC STORAGE

UP TO 3.66 M ABOVE THE FLOOR

ΕΙΔΙΚΗΣ ΠΑΡΟΥΣΙΑΣ ΑΤΟΜΩΝ ΑΠΟΘΗΚΗ, ΑΠΟΘΗΚΗ

ΔΙΑΦΟΡΩΝ ΕΙΔΩΝ ΕΩΣ ΤΟΥ 3.66 Μ ΠΑΝΩ

ΑΠΟ ΤΟ ΔΑΠΕΔΟ

F-400

B1

A1

F-301

B3

F-400

MATCHLINE - SEE SHEET

ΓΡΑΜΜΗ ΣΥΝΑΡΜΟΓΗΣ -

ΒΛΕΠΕ ΣΧΕΔΙΟ

F-115

F-115

M A

T C

H L

IN

E

S

E E

S H

E E

T Γ Ρ

Α Μ

Μ Η

Σ Υ

Ν Α

Ρ Μ

Ο Γ Η

Σ

Β Λ

Ε Π

Ε Σ

Χ Ε

Δ

ΙΟ

F -1

F -1

M A

T C

H L

IN

E

S

E E

S H

E E

T Γ Ρ

Α Μ

Μ Η

Σ Υ

Ν Α

Ρ Μ

Ο Γ Η

Σ

Β Λ

Ε Π

Ε Σ

Χ Ε

Δ

ΙΟ

F -1

F -1

A1

F-302

6 7 8 9

B

C

D

E

A

CA

CB

CC

CD

5.1 5.9

COMM

ELEC

MECHANICAL

STORAGE

SUPPLY CAGED

STORAGE

CARGO BAY

SUPPLY

STORAGE

FIRE EQ. ROOM

SM

H

1 5 8 14 16

CA

CB

CE

CH

CG

B

C

K

G

D

C

B

1 2 3 4 5

1568016

DWG

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.

SCALE:

N62470-23-C-XXXX

RICHARD L STEPHENS, P.E.

LMM/MWL

CHIEF ENG/ARCH

DES DRW CHK

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

TI

O N

D A

TE

A

P P

R

S O

U D

A B

A Y

SHEET KEYED NOTES:

ΠΑΡΑΤΗΡΗΣΕΙΣ ΣΧΕΔΙΟΥ:

GENERAL NOTES:

ΓΕΝΙΚΕΣ ΠΑΡΑΤΗΡΗΣΕΙΣ:

A KEYPLAN:

ΣΧΕΔΙΟ ΚΛΕΙΔΙ:

DRAWFORM REVISION: 25 AUGUST 2020

1 2 3 4 5

D

C

B

A

UNCLASSIFIED

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

A T

L A

N T

IC

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

N O

R F

O L K

V

A L A

N T

C A

P

IT

A L I M

P R

O V

E M

E N

T S

BRANCH MANAGER

PM/DM

SATISFACTORY TO DATE

FIRE PROTECTION DPS (DOUG STULTZ)

DPS (DOUG STULTZ)

/3

/2

:1 :0

A

M d c v s

\F

E D

P R

J \6

\F ir e

P ro te c ti o n \P

-1

-F

P

R

.r v t

03/31/2023

F-118

CLO WPS BVP

P J

O

IN

T M

O B

IL

IT

Y P

R O

C E

S S

IN

G

F A

C

IL

IT

Y

S O

U D

A B

A Y

G

R E

E C

E

F L

O O

R P

L A

N

L E

V E

L

S

E C

T O

R H

14068641

F -1

Κ Α

Τ Ο

Ψ Η

Ε

Π

ΙΠ

Ε Δ

Ο

Τ Ο

Μ Ε

Α Σ

H

0 5000 10000

MILLIMETRESSCALE 1:100

30001000

1. FIRE MAIN. SEE CIVIL DRAWING FOR CONTINUATION.

ΚΕΝΤΡΙΚΗ ΠΥΡΟΣΒΕΣΗΣ. ΔΕΣ ΤΑ ΣΧΕΔΙΑ ΤΟΥ ΠΟΛΙΤΙΚΟΥ

ΜΗΧΑΝΙΚΟΥ ΓΙΑ ΤΗΝ ΣΥΝΕΧΕΙΑ.

2. FIRE DEPARTMENT EQUIPMENT ROOM SEE DRAWING F-200 FOR

ENLARGED PLAN.

ΔΩΜΑΤΙΟ ΕΞΟΠΛΙΣΜΟΥ ΤΗΣ ΠΥΡΟΣΒΕΣΤΙΚΗΣ ΥΠΗΡΕΣΙΑΣ ΔΕΣ ΣΧΕΔΙΟ

F-200 ΓΙΑ ΜΕΓΕΝΘΥΜΕΝΗ ΚΑΤΟΨΗ.

3. FIRE SPRINKLER MAIN.

ΚΥΡΙΑ ΣΩΛΗΝΑ ΚΑΤΑΙΟΝΗΤΗΡΩΝ ΠΥΡΟΣΒΕΣΗΣ.

4. FIRE DEPARTMENT CLASS I STANDPIPE.

ΚΑΤΗΓΟΡΙΑΣ Ι ΣΩΛΗΝΑ ΣΤΑΘΕΡΗΣ ΠΙΕΣΗΣ ΤΗΣ ΠΥΡΟΣΒΕΣΤΙΚΗΣ

ΥΠΗΡΕΣΙΑΣ.

5. PROVIDE DRY PENDANT SPRINKLER HEADS WITH HEAD GUARDS

IN THIS AREA. SEE DETAIL C4/F-508.

ΠΡΟΜΗΘΕΥΣΤΕ ΚΡΕΜΑΣΤΕΣ ΚΕΦΑΛΕΣ ΚΑΤΑΙΟΝΗΤΗΡΩΝ ΣΤΕΓΝΟΥ

ΤΥΠΟΥ ΜΕ ΠΡΟΣΤΑΤΕΥΤΙΚΑ ΚΕΦΑΛΩΝ ΣΕ ΑΥΤΗ ΤΗΝ ΠΕΡΙΟΧΗ.

ΔΕΣ ΛΕΠΤΟΜΕΡΕΙΑ C4/F-508.

6. FORKLIFT & CARGO PATH.

ΔΙΑΔΡΟΜΗ ΠΕΡΟΝΟΦΟΡΟΥ ΑΝΥΨΩΤΙΚΟΥ ΚΑΙ ΕΜΠΟΡΕΥΜΑΤΩΝ.

7. FIRE PIPE TO FDC, SEE CIVIL FOR CONTINUATION.

ΣΗΛΗΝΑ ΠΥΡΟΣΒΕΣΗΣ ΠΡΟΣ FDC, ΔΕΣ ΤΑ ΣΧΕΔΙΑ ΤΟΥ ΠΟΛΙΤΙΚΟΥ

ΜΗΧΑΝΙΚΟΥ ΓΙΑ ΤΗΝ ΣΥΝΕΧΕΙΑ.

1 : 100

FLOOR PLAN - LEVEL 1 - SECTOR H

ΚΑΤΟΨΗ - ΕΠΙΠΕΔΟ 1 - ΤΟΜΕΑΣ H

PLAN NORTH

A. REFER TO DRAWING F-001 FOR LEGEND, ABBREVIATIONS AND

FIRE SPRINKLER NOTES.

ΑΝΑΤΡΕΞΤΕ ΣΤΟ ΣΧΕΔΙΟ F-001 ΓΙΑ ΤΑ ΥΠΟΜΝΗΜΑΤΑ, ΤΙΣ

ΣΥΝΤΟΜΟΓΡΑΦΙΕΣ ΚΑΙ ΤΙΣ ΠΑΡΑΤΗΡΗΣΕΙΣ ΤΩΝ ΚΑΤΑΙΟΝΗΤΗΡΩΝ

ΠΥΡΚΑΓΙΑΣ.

B. REFER TO LIFE SAFETY PLANS FOR LOCATIONS OF FIRE RATED

WALLS.

ΑΝΑΤΡΕΞΤΕ ΣΤΑ ΣΧΕΔΙΑΠΑΘΗΤΙΚΗΣ ΠΥΡΟΠΡΟΣΤΑΣΙΑΣ ΓΙΑ ΤΙΣ ΘΕΣΕΙΣ

ΤΩΝ ΔΙΑΒΑΘΜΙΣΜΕΝΩΝ ΤΟΙΧΩΜΑΤΩΝ ΠΥΡΚΑΓΙΑΣ.

C. PENETRATION OF WALL OR FLOORS MUST BE SEALED.

SEE DETAILS C1/F-503 AND C4/F503.

ΟΙ ΔΙΑΤΡΗΣΕΙΣ ΣΤΑ ΔΑΠΕΔΑ ΚΑΙ ΤΟΥΣ ΤΟΙΧΟΥΣ ΠΡΕΠΕΙ ΝΑ

ΣΦΡΑΓΙΖΟΝΤΑΙ ΚΑΤΑΛΛΗΛΩΣ. ΔΕΙΤΕ ΤΙΣ

ΛΕΠΤΟΜΕΡΕΙΕΣ C1/F-503 ΚΑΙ C4/F505.

D. SEISMIC BRACING IS REQUIRED. SEISMIC BRACING MUST BE

PROVIDED PER NFPA 13 AND DETAILS B1/F-505.

ΣΕΙΣΜΙΚΗ ΣΤΗΡΙΞΗ ΑΠΑΙΤΕΙΤΑΙ. Η ΣΕΙΣΜΙΚΗ ΣΤΗΡΙΞΗ ΠΡΕΠΕΙ ΝΑ

ΕΓΚΑΤΑΣΤΑΘΕΙ ΣΥΜΦΩΝΑ ΜΕ ΤΟΝ NFPA 13

ΚΑΙ ΤΙΣ ΛΕΠΤΟΜΕΡΕΙΕΣ B1/F-505.

1:100

APPROVED BY: PAM COWDEN, P.E.

yright 2007

T ectonic Cop yright 2007

Tectonic Copyright 2007

T ectonic Cop yright 2007

T ectonic Cop yright 2007

T ectonic Cop yright 2007

F-122

A1 F-121

A1

SECTOR A

SHEET A-121

SECTOR B

SHEET A-122

108 9 11 12 13 14 14.4 15 16

C

D

E

F

G

H

K

J

12.5 14.6

12.3 14.814.512.4

G.7

10.5

CC

CD

CE

CF

CG

CH

H.5

J.5

14.2

E.3

SPRINKLER HAZARD CLASSIFICATION

ΚΑΤΑΤΑΞΗ ΚΙΝΔΥΝΟΥΚΑΤΑΙΟΝΗΤΗΡΑ

LIGHT HAZARD

ΕΛΑΦΡΥΣ ΚΙΝΔΥΝΟΣ

ORDINARY HAZARD

ΣΥΝΗΘΗΣ ΚΙΝΔΥΝΟΣ

SPECIAL OCCUPANCY WAREHOUSE, MISC STORAGE

UP TO 3.66 M ABOVE THE FLOOR

ΕΙΔΙΚΗΣ ΠΑΡΟΥΣΙΑΣ ΑΤΟΜΩΝ ΑΠΟΘΗΚΗ, ΑΠΟΘΗΚΗ

ΔΙΑΦΟΡΩΝ ΕΙΔΩΝ ΕΩΣ ΤΟΥ 3.66 Μ ΠΑΝΩ

ΑΠΟ ΤΟ ΔΑΠΕΔΟ

SM

G H C D

B A

EF

1 5 8 14 16

CA

CB

CE

CH

CG

B

C

K

G

D

C

B

1 2 3 4 5

1568016

DWG

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.

SCALE:

N62470-23-C-XXXX

RICHARD L STEPHENS, P.E.

LMM/MWL

CHIEF ENG/ARCH

DES DRW CHK

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

TI

O N

D A

TE

A

P P

R

S O

U D

A B

A Y

SHEET KEYED NOTES:

ΠΑΡΑΤΗΡΗΣΕΙΣ ΣΧΕΔΙΟΥ:

GENERAL NOTES:

ΓΕΝΙΚΕΣ ΠΑΡΑΤΗΡΗΣΕΙΣ:

A KEYPLAN:

ΣΧΕΔΙΟ ΚΛΕΙΔΙ:

DRAWFORM REVISION: 25 AUGUST 2020

1 2 3 4 5

D

C

B

A

UNCLASSIFIED

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

A T

L A

N T

IC

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

N O

R F

O L K

V

A L A

N T

C A

P

IT

A L I M

P R

O V

E M

E N

T S

BRANCH MANAGER

PM/DM

SATISFACTORY TO DATE

FIRE PROTECTION DPS (DOUG STULTZ)

DPS (DOUG STULTZ)

/3

/2

:1 :1

A

M d c v s

\F

E D

P R

J \6

\F ir e

P ro te c ti o n \P

-1

-F

P

R

.r v t

03/31/2023

F-120

CLO WPS BVP

P J

O

IN

T M

O B

IL

IT

Y P

R O

C E

S S

IN

G

F A

C

IL

IT

Y

S O

U D

A B

A Y

G

R E

E C

E

F L

O O

R P

L A

N

L E

V E

L

O

V E

R A

L L

14068642

F -1

Κ Α

Τ Ο

Ψ Η

Ε

Π

ΙΠ

Ε Δ

Ο

Σ Υ

Ν Ο

Λ

ΙΚ

Ο

1 : 200

FLOOR PLAN - LEVEL 2 - OVERALL

ΚΑΤΟΨΗ - ΕΠΙΠΕΔΟ 2 - ΣΥΝΟΛΙΚΟ

0 10000 20000

MILLIMETRESSCALE 1:200

40002000

1. FIRE SPRINKLER MAIN UP FROM BELOW.

ΚΥΡΙΑ ΚΑΤΑΙΟΝΗΤΗΡΩΝ ΠΥΡΟΣΒΕΣΗΣ ΠΡΟΣ ΤΑ ΠΑΝΩ ΑΠΟ ΚΑΤΩ.

2. FIRE SPRINKLER MAIN.

ΚΥΡΙΑ ΚΑΤΑΙΟΝΗΤΗΡΩΝ ΠΥΡΟΣΒΕΣΗΣ.

3. FIRE DEPARTMENT VALVE 65 MM AT 915 MM ABOVE FLOOR

ΒΑΝΑ ΣΥΝΔΕΣΗΣ ΠΥΡΟΣΒΕΣΤΙΚΗΣ ΥΠΗΡΕΣΙΑΣ 65 ΜΜ ΣΤΑ

915 ΜΜ ΠΑΝΩ ΑΠΟ ΤΟ ΔΑΠΕΔΟ.

4. SPRINKLER HEADS AT TOP OF STAIRS.

ΚΕΦΑΛΕΣ ΚΑΤΑΙΟΝΗΤΗΡΩΝ ΣΤΗΝ ΚΟΡΥΦΗ ΤΟΥ ΚΛΙΜΑΚΟΣΤΑΣΙΟΥ.

PLAN NORTH

A. REFER TO DRAWING F-001 FOR LEGEND, ABBREVIATIONS AND

FIRE SPRINKLER NOTES.

ΑΝΑΤΡΕΞΤΕ ΣΤΟ ΣΧΕΔΙΟ F-001 ΓΙΑ ΤΑ ΥΠΟΜΝΗΜΑΤΑ, ΤΙΣ

ΣΥΝΤΟΜΟΓΡΑΦΙΕΣ ΚΑΙ ΤΙΣ ΠΑΡΑΤΗΡΗΣΕΙΣ ΤΩΝ ΚΑΤΑΙΟΝΗΤΗΡΩΝ

ΠΥΡΚΑΓΙΑΣ.

B. REFER TO LIFE SAFETY PLANS FOR LOCATIONS OF FIRE RATED

WALLS.

ΑΝΑΤΡΕΞΤΕ ΣΤΑ ΣΧΕΔΙΑ ΠΑΘΗΤΙΚΗΣ ΠΥΡΟΠΡΟΣΤΑΣΙΑΣΓΙΑ ΤΙΣ ΘΕΣΕΙΣ

ΤΩΝ ΔΙΑΒΑΘΜΙΣΜΕΝΩΝ ΤΟΙΧΩΜΑΤΩΝ ΠΥΡΚΑΓΙΑΣ.

C. PENETRATION OF WALL OR FLOORS MUST BE SEALED.

SEE DETAILS C1/F-503 AND C4/F503.

ΟΙ ΔΙΑΤΡΗΣΕΙΣ ΣΤΑ ΔΑΠΕΔΑ ΚΑΙ ΤΟΥΣ ΤΟΙΧΟΥΣ ΠΡΕΠΕΙ ΝΑ

ΣΦΡΑΓΙΖΟΝΤΑΙ ΚΑΤΑΛΛΗΛΩΣ. ΔΕΙΤΕ ΤΙΣ

ΛΕΠΤΟΜΕΡΕΙΕΣ C1/F-503 ΚΑΙ C4/F503.

D. SEISMIC BRACING IS REQUIRED. SEISMIC BRACING MUST BE

PROVIDED PER NFPA 13 AND DETAILS B1/F-505.

ΣΕΙΣΜΙΚΗ ΣΤΗΡΙΞΗ ΑΠΑΙΤΕΙΤΑΙ. Η ΣΕΙΣΜΙΚΗ ΣΤΗΡΙΞΗ ΠΡΕΠΕΙ ΝΑ

ΕΓΚΑΤΑΣΤΑΘΕΙ ΣΥΜΦΩΝΑ ΜΕ ΤΟΝ NFPA 13

ΚΑΙ ΤΙΣ ΛΕΠΤΟΜΕΡΕΙΕΣ B1/F-505.

1:200

APPROVED BY: PAM COWDEN, P.E.

yright 2007

NS

M A

T C

H L

IN

E

S

E E

S H

E E

T Γ Ρ

Α Μ

Μ Η

Σ Υ

Ν Α

Ρ Μ

Ο Γ Η

Σ

Β Λ

Ε Π

Ε Σ

Χ Ε

Δ

ΙΟ

F -1

F -1

14 14.4 15 16

E

F

G

H

K

J

14.6

14.814.514.2

E.3STAIR 1

ELEC

COMM

MECH

SIPR / NIPR

218CONF

PORT OPS OFC

PORT OPS OFC

PORT OPS

DET SUP OFC

DET SUP OFC

BREAK

DET SUP

TRAINING

CORR

GRND ELEC

CORR

ELEV

A1

F-303

SPRINKLER HAZARD CLASSIFICATION

ΚΑΤΑΤΑΞΗ ΚΙΝΔΥΝΟΥΚΑΤΑΙΟΝΗΤΗΡΑ

LIGHT HAZARD

ΕΛΑΦΡΥΣ ΚΙΝΔΥΝΟΣ

ORDINARY HAZARD

ΣΥΝΗΘΗΣ ΚΙΝΔΥΝΟΣ

SPECIAL OCCUPANCY WAREHOUSE, MISC STORAGE

UP TO 3.66 M ABOVE THE FLOOR

ΕΙΔΙΚΗΣ ΠΑΡΟΥΣΙΑΣ ΑΤΟΜΩΝ ΑΠΟΘΗΚΗ, ΑΠΟΘΗΚΗ

ΔΙΑΦΟΡΩΝ ΕΙΔΩΝ ΕΩΣ ΤΟΥ 3.66 Μ ΠΑΝΩ

ΑΠΟ ΤΟ ΔΑΠΕΔΟ

SM

A

1 5 8 14 16

CA

CB

CE

CH

CG

B

C

K

G

D

C

B

1 2 3 4 5

1568016

DWG

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.

SCALE:

N62470-23-C-XXXX

RICHARD L STEPHENS, P.E.

LMM/MWL

CHIEF ENG/ARCH

DES DRW CHK

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

TI

O N

D A

TE

A

P P

R

S O

U D

A B

A Y

SHEET KEYED NOTES:

ΠΑΡΑΤΗΡΗΣΕΙΣ ΣΧΕΔΙΟΥ:

GENERAL NOTES:

ΓΕΝΙΚΕΣ ΠΑΡΑΤΗΡΗΣΕΙΣ:

A KEYPLAN:

ΣΧΕΔΙΟ ΚΛΕΙΔΙ:

DRAWFORM REVISION: 25 AUGUST 2020

1 2 3 4 5

D

C

B

A

UNCLASSIFIED

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

A T

L A

N T

IC

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

N O

R F

O L K

V

A L A

N T

C A

P

IT

A L I M

P R

O V

E M

E N

T S

BRANCH MANAGER

PM/DM

SATISFACTORY TO DATE

FIRE PROTECTION DPS (DOUG STULTZ)

DPS (DOUG STULTZ)

/3

/2

:1 :1

A

M d c v s

\F

E D

P R

J \6

\F ir e

P ro te c ti o n \P

-1

-F

P

R

.r v t

03/31/2023

F-121

CLO WPS BVP

P J