Attachment G_ Drawings_ Part3 of 5.pdf
PDF 42 MB Posted
- Attached to
- Z2DA--EHRM Upgrade Server Room and Site Communication Infrastructure Federal contract opportunity
- Solicitation number
- 36C26221B0011_1
About this file
This solicitation is for construction services to perform upgrades to the EHRM server room and site communication infrastructure at the VA Greater Los Angeles Healthcare System. The work includes general construction, alterations, mechanical, electrical and utility systems work. All work must be performed in accordance with the terms, conditions, specifications and drawings of the solicitation and applicable building codes. This is a 100% set-aside for Service-Disabled Veteran-Owned Small Businesses listed as verified on VIP database. The point of contact for questions is Steven J. Covell, Contracting Specialist, via email at steve.covell@va.gov.
View the file
Other files for this federal contract opportunity
Show all 22
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
J
120VAC
4 3
J
J
W.257.E-401
ELECTRICAL ENLARGED PLAN -
TR ROOM, 135
0' 2' 4' 12'
SCALE: 1/4" = 1'-0"
Project Number
Campus / Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
F i l e
P a t h
U.S. Department of Veterans Affairs
B
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
Key Plan
Upgrade Server Room and Site Communication Infrastructure
11301 WILSHIRE BOULEVARD,
WEST LOS ANGELES, CA 90073
691-20-152FINAL CONSTRUCTION
DOCUMENTS
JULY 13, 2021 PM EW/JB
FULLY SPRINKLERED
A
GENERAL NOTES
ARCHITECT/ENGINEER OF RECORD
C
D
17075 Via Del Campo, San Diego, CA 92127
Phone: 858.946.0333
20801.11 20-SCE-06
GENERAL NOTE
FIRE PROTECTION
1. DO NOT MAKE ANY ATTACHMENTS OR MODIFICATIONS TO
ANY FIREPROOFED COMPONENTS.
SYMBOLS LIST
2 HOUR FIRE BARRIER
1 HOUR FIRE BARRIER
2 HOUR FIRE/SMOKE BARRIER
SMOKE BARRIER
SMOKE PARTITION
1 HOUR FIRE/SMOKE BARRIER
3 HOUR FIRE BARRIER
KEY NOTES
NEW HIRSCH ACCESS CONTROL PANEL.
NEW PIV READER. SEE E-503 FOR CONDUIT
REQUIREMENT.
3/4''C- 2 #12 + 1 #12EG
CONNECT TO EXISTING CIRCUIT IN TR ROOM.
TO HIRSCH ACCESS CONTROL PANEL. SEE
KEYNOTE 1 & ACCESS CONTROL RISER
DIAGRAM ON T-600 SERIES DRAWING.
SCALE: 1/4" = 1' - 0"
NORTH
TR ROOM
B
SCALE: 1/4" = 1' - 0"
NORTH
TR ROOM
1.
2.
SCALE: 1/4" = 1' - 0"
NORTH
TR ROOM
120VAC
J
J
J
J
J
J
J
J
W.258.E-401
Project Number
Campus / Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
F i t h
U.S. Department of Veterans Affairs
B
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
Upgrade Server Room and Site Communication Infrastructure
11301 WILSHIRE BOULEVARD,
WEST LOS ANGELES, CA 90073
691-20-152FINAL CONSTRUCTION
DOCUMENTS
JULY 13, 2021 PM EW/JB
FULLY SPRINKLERED
A
GENERAL NOTES
ARCHITECT/ENGINEER OF RECORD
C
D
17075 Via Del Campo, San Diego, CA 92127
Phone: 858.946.0333
20801.11 20-SCE-06
GENERAL NOTE
FIRE PROTECTION
1. DO NOT MAKE ANY ATTACHMENTS OR MODIFICATIONS TO
ANY FIREPROOFED COMPONENTS.
SYMBOLS LIST
2 HOUR FIRE BARRIER
1 HOUR FIRE BARRIER
2 HOUR FIRE/SMOKE BARRIER
SMOKE BARRIER
SMOKE PARTITION
1 HOUR FIRE/SMOKE BARRIER
3 HOUR FIRE BARRIER
0' 2' 4' 12'
SCALE: 1/4" = 1'-0"
SCALE: 1/4" = 1' - 0"
NORTH
SCALE: 1/4" = 1' - 0"
NORTH
TR ROOM 105
TR ROOM 136A
SCALE: 1/4" = 1' - 0"
NORTH
SCALE: 1/4" = 1' - 0"
NORTH
TR ROOM 210A
TR ROOM 215
KEY NOTES
NEW HIRSCH ACCESS CONTROL PANEL.
NEW PIV READER. SEE E-503 FOR CONDUIT
REQUIREMENT.
3/4''C- 2 #12 + 1 #12EG
CONNECT TO EXISTING CIRCUIT IN TR ROOM.
TO HIRSCH ACCESS CONTROL PANEL. SEE
KEYNOTE 1 & ACCESS CONTROL RISER
DIAGRAM ON T-600 SERIES DRAWING.
1.
2.
TR ROOM 120
TR ROOM 104A
SCALE: 1/4" = 1' - 0"
NORTH
TR ROOM 404
SCALE: 1/4" = 1' - 0"
NORTH
TR ROOM 335
120VAC
J
SCALE: 1/4" = 1' - 0"
NORTH
W.259.E-401
ELECTRICAL ENLARGED PLAN -
TR ROOM
0' 2' 4' 12'
SCALE: 1/4" = 1'-0"
Project Number
Campus / Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
F i t h U.S. Department of Veterans Affairs
B
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
Key Plan
Upgrade Server Room and Site Communication Infrastructure
11301 WILSHIRE BOULEVARD,
WEST LOS ANGELES, CA 90073
691-20-152FINAL CONSTRUCTION
DOCUMENTS
JULY 13, 2021 PM EW/JB
FULLY SPRINKLERED
A
GENERAL NOTES
ARCHITECT/ENGINEER OF RECORD
C
D
17075 Via Del Campo, San Diego, CA 92127
Phone: 858.946.0333
20801.11 20-SCE-06
GENERAL NOTE
FIRE PROTECTION
1. DO NOT MAKE ANY ATTACHMENTS OR MODIFICATIONS TO
ANY FIREPROOFED COMPONENTS.
SYMBOLS LIST
2 HOUR FIRE BARRIER
1 HOUR FIRE BARRIER
2 HOUR FIRE/SMOKE BARRIER
SMOKE BARRIER
SMOKE PARTITION
1 HOUR FIRE/SMOKE BARRIER
3 HOUR FIRE BARRIER
KEY NOTES
NEW DOOR AND WALL
NEW HIRSCH ACCESS CONTROL PANEL.
NEW PIV READER. SEE E-503 FOR CONDUIT
REQUIREMENT.
3/4''C- 2 #12 + 1 #12EG
CONNECT TO EXISTING CIRCUIT IN TR ROOM.
TO HIRSCH ACCESS CONTROL PANEL. SEE
KEYNOTE 1 & ACCESS CONTROL RISER
DIAGRAM ON T-600 SERIES DRAWING.
1.
2.
UP
SCALE: 1/4" = 1' - 0"
NORTH
W.295.E-401
ELECTRICAL ENLARGED PLAN -
TR ROOM
0' 2' 4' 12'
SCALE: 1/4" = 1'-0"
Project Number
Campus / Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
F i t h
U.S. Department of Veterans Affairs
B
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
Key Plan
Upgrade Server Room and Site Communication Infrastructure
11301 WILSHIRE BOULEVARD,
WEST LOS ANGELES, CA 90073
691-20-152FINAL CONSTRUCTION
DOCUMENTS
JULY 13, 2021 PM EW/JB
FULLY SPRINKLERED
A
GENERAL NOTES
ARCHITECT/ENGINEER OF RECORD
C
D
17075 Via Del Campo, San Diego, CA 92127
Phone: 858.946.0333
20801.11 20-SCE-06
GENERAL NOTE
FIRE PROTECTION
1. DO NOT MAKE ANY ATTACHMENTS OR MODIFICATIONS TO
ANY FIREPROOFED COMPONENTS.
SYMBOLS LIST
2 HOUR FIRE BARRIER
1 HOUR FIRE BARRIER
2 HOUR FIRE/SMOKE BARRIER
SMOKE BARRIER
SMOKE PARTITION
1 HOUR FIRE/SMOKE BARRIER
3 HOUR FIRE BARRIER
NEW FIBER TERMINAL DISTRIBUTION UNIT TDU.
TERMINATE FIBER ON FIBER PATCH PANEL.
KEY NOTES
1 120VAC
J
5 2
SCALE: 1/4" = 1' - 0"
NORTH
W.297.E-401
ELECTRICAL ENLARGED PLAN -
TR ROOM
0' 2' 4' 12'
SCALE: 1/4" = 1'-0"
Project Number
Campus / Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
F i t h
U.S. Department of Veterans Affairs
B
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
Key Plan
Upgrade Server Room and Site Communication Infrastructure
11301 WILSHIRE BOULEVARD,
WEST LOS ANGELES, CA 90073
691-20-152FINAL CONSTRUCTION
DOCUMENTS
JULY 13, 2021 PM EW/JB
FULLY SPRINKLERED
A
GENERAL NOTES
ARCHITECT/ENGINEER OF RECORD
C
D
17075 Via Del Campo, San Diego, CA 92127
Phone: 858.946.0333
20801.11 20-SCE-06
GENERAL NOTE
FIRE PROTECTION
1. DO NOT MAKE ANY ATTACHMENTS OR MODIFICATIONS TO
ANY FIREPROOFED COMPONENTS.
SYMBOLS LIST
2 HOUR FIRE BARRIER
1 HOUR FIRE BARRIER
2 HOUR FIRE/SMOKE BARRIER
SMOKE BARRIER
SMOKE PARTITION
1 HOUR FIRE/SMOKE BARRIER
3 HOUR FIRE BARRIER
KEY NOTES
NEW HIRSCH ACCESS CONTROL PANEL.
3/4''C- 2 #12 + 1 #12EG
CONNECT TO EXISTING CIRCUIT IN TR ROOM.
TO HIRSCH ACCESS CONTROL PANEL. SEE
KEYNOTE 1 & ACCESS CONTROL RISER
DIAGRAM ON T-600 SERIES DRAWING.
1.
120VAC
J
W.300.E-401
ELECTRICAL ENLARGED PLAN -
TR ROOM 106 AND 206B
0' 2' 4' 12'
SCALE: 1/4" = 1'-0"
Project Number
Campus / Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
F i t h
U.S. Department of Veterans Affairs
B
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
Key Plan
Upgrade Server Room and Site Communication Infrastructure
11301 WILSHIRE BOULEVARD,
WEST LOS ANGELES, CA 90073
691-20-152FINAL CONSTRUCTION
DOCUMENTS
JULY 13, 2021 PM EW/JB
FULLY SPRINKLERED
A
GENERAL NOTES
ARCHITECT/ENGINEER OF RECORD
C
D
17075 Via Del Campo, San Diego, CA 92127
Phone: 858.946.0333
20801.11 20-SCE-06
GENERAL NOTE
FIRE PROTECTION
1. DO NOT MAKE ANY ATTACHMENTS OR MODIFICATIONS TO
ANY FIREPROOFED COMPONENTS.
SYMBOLS LIST
2 HOUR FIRE BARRIER
1 HOUR FIRE BARRIER
2 HOUR FIRE/SMOKE BARRIER
SMOKE BARRIER
SMOKE PARTITION
1 HOUR FIRE/SMOKE BARRIER
3 HOUR FIRE BARRIER
KEY NOTES
SCALE: 1/4" = 1' - 0"
NORTH
TR ROOM
SCALE: 1/4" = 1' - 0"
NORTH
TR ROOM
206-B
NEW HIRSCH ACCESS CONTROL PANEL.
NEW PIV READER. SEE E-503 FOR CONDUIT
REQUIREMENT.
3/4''C- 2 #12 + 1 #12EG
CONNECT TO EXISTING CIRCUIT IN TR ROOM.
TO HIRSCH ACCESS CONTROL PANEL. SEE
KEYNOTE 1 & ACCESS CONTROL RISER
DIAGRAM ON T-600 SERIES DRAWING.
1.
FROM NEW
TELEPHONE
MANHOLE
OUTDOOR
TELEPHONE
CABINET
TO OLD
SIGNAL
MANHOLE
34 2
11 12
16 7
POST COLUMN
TO REMAIN
OFFICE
CONFERENCE ROOM
MAIN TELECOM
DISTRIBUTION HUB
NIC
OFFICE
OFFICE
CONFERENCE ROOM
NIC
LOUNGE
OFFICE
NIC
RESTROOM 1
NIC
OFFICE
NIC
RESTROOM 2
DN
SCALE: 1/4" = 1' - 0" NORTH
W.301.E-401
1 FAPP-301 NETWORK FIBER LOOP 2 & FIREWORK NETWORK TO REMAIN
FAPP-301 NETWORK FIBER LOOP 3 & FIREWORK NETWORK TO REMAIN
FAPP-301 NETWORK FIBER LOOP 4 & FIREWORK NETWORK TO REMAIN
VIDEO SURVEILLANCE EQUIPMENT RACK TO REMAIN BUT RELOCATED
EXISTING LADDER RACK TO REMAIN
EXISTING ABANDONED PNEUMATIC SYSTEM CABINET & ASSOCIATED TUBE
COMING UP FROM U/G CONDUIT TO BE REMOVED AND PULLED OUT TO
MAKE ROOM FOR NEW FIBER.
EXISTING PANEL 301 100A 208/120V TO REMAIN
EXISTING SUB PANEL TO BE REMOVED. REMOVE CIRCUIT BREAKERS &
TURN IT OVER TO VA ELECTRICAL SHOP BEFORE DISPOSING OFF PANEL.
EXISTING WALL TO BE DEMOLITION.
EXISTING 110 BLOCK FOR PATCHING DATA CABLE TO BE REPLACED WITH
PATCH PANEL
EXISTING 110 RACK TO REMAIN.
EXISTING ABANDONED DUKANE SOUND SYSTEM CABINET TO BE
DISCONNECTED AND REMOVED
EXISTING CEILING MOUNTED FCU UNIT TO BE ELECTRICALLY
DISCONNECTED FOR SAFE REMOVED BY MECHANICAL CONTRACTOR.
EXISTING OUTDOOR CONDENSING UNIT TO BE ELECTRICALLY
DISCONNECTED FOR SAFE REMOVAL BY MECHANICAL CONTRACTOR.
EXISTING RACK WITH FIBER PATCH PANEL TO BE REMOVED AFTER NEW
FIBER SYSTEM IS IN PLACED AND COMMISSIONED. ALL EXISTING FIBER TO
BE PULLED OUT ALL THE WAY TO THE MANHOLE.
EXISTING SURFACE MOUNTED FIXTURES TO BE DISCONNECTED AND
REMOVED AND REPLACED.
EXISTING POWER SUPPLY RACK TO BE DISCONNECTED AND REMOVED.
KEY NOTES
Project Number
Campus / Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
F i t h
U.S. Department of Veterans Affairs
B
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
Key Plan
Upgrade Server Room and Site Communication Infrastructure
11301 WILSHIRE BOULEVARD,
WEST LOS ANGELES, CA 90073
691-20-152FINAL CONSTRUCTION
DOCUMENTS
JULY 13, 2021 PM EW/JB
FULLY SPRINKLERED
A
GENERAL NOTES
ARCHITECT/ENGINEER OF RECORD
C
D
17075 Via Del Campo, San Diego, CA 92127
Phone: 858.946.0333
20801.11 20-SCE-06
GENERAL NOTE
FIRE PROTECTION
1. DO NOT MAKE ANY ATTACHMENTS OR MODIFICATIONS TO
ANY FIREPROOFED COMPONENTS.
SYMBOLS LIST
2 HOUR FIRE BARRIER
1 HOUR FIRE BARRIER
2 HOUR FIRE/SMOKE BARRIER
SMOKE BARRIER
SMOKE PARTITION
1 HOUR FIRE/SMOKE BARRIER
3 HOUR FIRE BARRIER
W.301.E-402
Project Number
Campus / Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
F i t h U.S. Department of Veterans Affairs
B
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
Upgrade Server Room and Site Communication Infrastructure
11301 WILSHIRE BOULEVARD,
WEST LOS ANGELES, CA 90073
691-20-152FINAL CONSTRUCTION
DOCUMENTS
JULY 13, 2021 PM EW/JB
FULLY SPRINKLERED
A
ARCHITECT/ENGINEER OF RECORD
C
D
17075 Via Del Campo, San Diego, CA 92127
Phone: 858.946.0333
20801.11 20-SCE-06
SCALE: NONE SCALE: NONESCALE: NONE SCALE: NONE SCALE: NONE SCALE: NONE
SCALE: NONE SCALE: NONE SCALE: NONE SCALE: NONE SCALE: NONE SCALE: NONE
SCALE: NONE SCALE: NONE SCALE: NONE SCALE: NONE SCALE: NONE
CONFERENCE ROOM
MAIN TELECOM
DISTRIBUTION HUB
CONFERENCE ROOM
NIC
LOUNGE
OFFICE
NIC
RESTROOM 1
NIC
OFFICE
NIC
RESTROOM 2
DN
FROM NEW
TELEPHONE
MANHOLE
OUTDOOR
TELEPHONE
CABINET
TO OLD
SIGNAL
MANHOLE
34 2
3 12
120VAC
J 14
UPSA-1
12 12
CU
B301 COND1
T-301-14,16,18
T-301-12
WP
GFI
CRAC
B301 VRAC1DB 301 PL
CONFERENCE ROOM
MAIN TELECOM
DISTRIBUTION HUB
CONFERENCE ROOM
NIC
LOUNGE
OFFICE
NIC
RESTROOM 1
NIC
OFFICE
NIC
RESTROOM 2
DN
J
CONFERENCE ROOM
MAIN TELECOM
DISTRIBUTION HUB
CONFERENCE ROOM
NIC
LOUNGE
OFFICE
NIC
RESTROOM 1
NIC
OFFICE
NIC
RESTROOM 2
DN
UPB-1,3
UPA-1,3
RACK1 RACK 2
UPB-10,12
UPA-10,12
UP
B-
6,8
UP
A-
6,8
RACK 3 RACK 4 RACK 5 RACK 6
UP
B-
2,4
UP
A-
2,4
UPA-9,11
UPB-9,11
UPB-5,7
UPA-5,7
26 TYPICAL FOR 12
SCALE: 1/4" = 1' - 0" NORTH
W.301.E-403
Project Number
Campus / Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
F i t h
U.S. Department of Veterans Affairs
B
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
Upgrade Server Room and Site Communication Infrastructure
11301 WILSHIRE BOULEVARD,
WEST LOS ANGELES, CA 90073
691-20-152FINAL CONSTRUCTION
DOCUMENTS
JULY 13, 2021 PM EW/JB
FULLY SPRINKLERED
A
GENERAL NOTES
ARCHITECT/ENGINEER OF RECORD
C
D
17075 Via Del Campo, San Diego, CA 92127
Phone: 858.946.0333
20801.11 20-SCE-06
GENERAL NOTE
FIRE PROTECTION
1. DO NOT MAKE ANY ATTACHMENTS OR MODIFICATIONS TO
ANY FIREPROOFED COMPONENTS.
SYMBOLS LIST
2 HOUR FIRE BARRIER
1 HOUR FIRE BARRIER
2 HOUR FIRE/SMOKE BARRIER
SMOKE BARRIER
SMOKE PARTITION
1 HOUR FIRE/SMOKE BARRIER
3 HOUR FIRE BARRIER
FAPP-301 NETWORK FIBER LOOP 2 & FIREWORK
NETWORK TO REMAIN.
FAPP-301 NETWORK FIBER LOOP 3 & FIREWORK
NETWORK TO REMAIN.
FAPP-301 NETWORK FIBER LOOP 4 & FIREWORK
NETWORK TO REMAIN.
EXISTING VIDEO SURVEILLANCE EQUIPMENT
RACK AT NEW LOCATION.
NOT USED.
NEW 40KVA UPS 208/120V 3P 4W W/ BYPASS &
BATTERY CABINET.
EXISTING PANEL T-301 100A 208/120V TO
REMAIN.
EXISTING 110 RACK TO REMAIN.
NEW 4 POST RACK.
NEW 18"W X 1 1/2" H LADDER RACK BLACK.
NEW HIRSCH ACCESS CONTROL PANEL.
NEW PIV READER. SEE E-503 FOR CONDUIT
REQUIREMENT.
3/4''C- 2 #12 + 1 #12EG.
TO HIRSCH ACCESS CONTROL PANEL. SEE
KEYNOTE 1 & ACCESS CONTROL RISER
DIAGRAM ON T-700 SERIES DRAWING.
NEW 100A/ 3P FUSED DISCONNECT.
1''C- 3 #4 + 1 #8EG.
NEW 30A/ 3P FUSED DISCONNECT NEMA 3R.
3/4''C- 3 #12 + 1 #12EG.
3/4''C- 2 #12 + 1 #12EG.
NEW PANEL UPA 100A 208/120V.
NEW PANEL UPB 100A 208/120V.
NEW 1 1/ 4''C- 4 #2 + 1 #8EG.
NEW 3/4''C- 3 #12 + 1 #12EG.
EXISTING FIXTURE TO BE REPLACED WITH
TYPE E .
EXISTING CRITICAL DISTRIBUTION BOARD 301
PL 800A 208/120V.
L21-20R MOUNTED ON SIDE OF LADDER RACK.
0' 2' 4' 8'
SCALE: 1/4" = 1'-0"
ALL CIRCUIT BREAKERS WILL BE TURNED
OVER TO VA ELECTRICAL SHOP
BEFORE DISPOSING OFF ELECTRICAL PANELS.
1.
2.
KEY NOTES
SCALE: 1/4" = 1' - 0" NORTH
SCALE: 1/4" = 1' - 0" NORTH
SCALE: NONE
3.
4.
OFFICE
CONFERENCE ROOM
MAIN TELECOM
DISTRIBUTION HUB
NIC
OFFICE
OFFICE
CONFERENCE ROOM
NIC
LOUNGE
OFFICE
NIC
RESTROOM 1
NIC
OFFICE
NIC
RESTROOM 2
DN
2 2
SCALE: 1/4" = 1' - 0" NORTH
W.301.E-404
1 NEW PENDANT MOUNTED LIGHTING FIXTURE.
EXISTING FIXTURE RE-CONFIGURED BOTH IN TERMS OF
PLACEMENT AND SWITCHING.
CONNECT TO EXISTING CIRCUIT.
UNSWITCHED NIGHT LIGHT.
Project Number
Campus / Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
F i t h
U.S. Department of Veterans Affairs
B
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
Key Plan
Upgrade Server Room and Site Communication Infrastructure
11301 WILSHIRE BOULEVARD,
WEST LOS ANGELES, CA 90073
691-20-152FINAL CONSTRUCTION
DOCUMENTS
JULY 13, 2021 PM EW/JB
FULLY SPRINKLERED
A
GENERAL NOTES
ARCHITECT/ENGINEER OF RECORD
C
D
17075 Via Del Campo, San Diego, CA 92127
Phone: 858.946.0333
20801.11 20-SCE-06
GENERAL NOTE
FIRE PROTECTION
1. DO NOT MAKE ANY ATTACHMENTS OR MODIFICATIONS TO
ANY FIREPROOFED COMPONENTS.
SYMBOLS LIST
2 HOUR FIRE BARRIER
1 HOUR FIRE BARRIER
2 HOUR FIRE/SMOKE BARRIER
SMOKE BARRIER
SMOKE PARTITION
1 HOUR FIRE/SMOKE BARRIER
3 HOUR FIRE BARRIER
0' 2' 4' 12'
SCALE: 1/4" = 1'-0"
KEY NOTES
120VAC
J
J
J
J
J
SCALE: 1/4" = 1' - 0"
NORTH
W.304.E-401
0' 2' 4' 12'
SCALE: 1/4" = 1'-0"
TR ROOM
2-2
Project Number
Campus / Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
F i t h
U.S. Department of Veterans Affairs
B
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
Upgrade Server Room and Site Communication Infrastructure
11301 WILSHIRE BOULEVARD,
WEST LOS ANGELES, CA 90073
691-20-152FINAL CONSTRUCTION
DOCUMENTS
JULY 13, 2021 PM EW/JB
FULLY SPRINKLERED
A
GENERAL NOTES
ARCHITECT/ENGINEER OF RECORD
C
D
17075 Via Del Campo, San Diego, CA 92127
Phone: 858.946.0333
20801.11 20-SCE-06
GENERAL NOTE
FIRE PROTECTION
1. DO NOT MAKE ANY ATTACHMENTS OR MODIFICATIONS TO
ANY FIREPROOFED COMPONENTS.
SYMBOLS LIST
2 HOUR FIRE BARRIER
1 HOUR FIRE BARRIER
2 HOUR FIRE/SMOKE BARRIER
SMOKE BARRIER
SMOKE PARTITION
1 HOUR FIRE/SMOKE BARRIER
3 HOUR FIRE BARRIER
KEY NOTES
SCALE: 1/4" = 1' - 0"
NORTH
TR ROOM
2-106B
SCALE: 1/4" = 1' - 0"
NORTH
TR ROOM
3-223A
SCALE: 1/4" = 1' - 0"
NORTH
TR ROOM
NEW HIRSCH ACCESS CONTROL PANEL.
NEW PIV READER. SEE E-503 FOR CONDUIT
REQUIREMENT.
3/4''C- 2 #12 + 1 #12EG
CONNECT TO EXISTING CIRCUIT IN TR ROOM.
TO HIRSCH ACCESS CONTROL PANEL. SEE
KEYNOTE 1 & ACCESS CONTROL RISER
DIAGRAM ON T-600 SERIES DRAWING.
1.
120VAC
J
W.305.E-401
ELECTRICAL ENLARGED PLAN -
TR ROOM LADIES LOUNGE
0' 2' 4' 12'
SCALE: 1/4" = 1'-0"
Project Number
Campus / Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
F i t h U.S. Department of Veterans Affairs
B
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
Key Plan
Upgrade Server Room and Site Communication Infrastructure
11301 WILSHIRE BOULEVARD,
WEST LOS ANGELES, CA 90073
691-20-152FINAL CONSTRUCTION
DOCUMENTS
JULY 13, 2021 PM EW/JB
FULLY SPRINKLERED
A
GENERAL NOTES
ARCHITECT/ENGINEER OF RECORD
C
D
17075 Via Del Campo, San Diego, CA 92127
Phone: 858.946.0333
20801.11 20-SCE-06
GENERAL NOTE
FIRE PROTECTION
1. DO NOT MAKE ANY ATTACHMENTS OR MODIFICATIONS TO
ANY FIREPROOFED COMPONENTS.
SYMBOLS LIST
2 HOUR FIRE BARRIER
1 HOUR FIRE BARRIER
2 HOUR FIRE/SMOKE BARRIER
SMOKE BARRIER
SMOKE PARTITION
1 HOUR FIRE/SMOKE BARRIER
3 HOUR FIRE BARRIER
SCALE: 1/4" = 1' - 0"
NORTH
KEY NOTES
NEW HIRSCH ACCESS CONTROL PANEL.
NEW PIV READER. SEE E-503 FOR CONDUIT
REQUIREMENT.
3/4''C- 2 #12 + 1 #12EG
CONNECT TO EXISTING CIRCUIT IN TR ROOM.
TO HIRSCH ACCESS CONTROL PANEL. SEE
KEYNOTE 1 & ACCESS CONTROL RISER
DIAGRAM ON T-600 SERIES DRAWING.
1.
120VAC
J
SCALE: 1/4" = 1' - 0"
NORTH
W.306.E-401
ELECTRICAL ENLARGED PLAN -
TR ROOM
0' 2' 4' 12'
SCALE: 1/4" = 1'-0"
TR ROOM
Project Number
Campus / Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
F i t h
U.S. Department of Veterans Affairs
B
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
Upgrade Server Room and Site Communication Infrastructure
11301 WILSHIRE BOULEVARD,
WEST LOS ANGELES, CA 90073
691-20-152FINAL CONSTRUCTION
DOCUMENTS
JULY 13, 2021 PM EW/JB
FULLY SPRINKLERED
A
GENERAL NOTES
ARCHITECT/ENGINEER OF RECORD
C
D
17075 Via Del Campo, San Diego, CA 92127
Phone: 858.946.0333
20801.11 20-SCE-06
GENERAL NOTE
FIRE PROTECTION
1. DO NOT MAKE ANY ATTACHMENTS OR MODIFICATIONS TO
ANY FIREPROOFED COMPONENTS.
SYMBOLS LIST
2 HOUR FIRE BARRIER
1 HOUR FIRE BARRIER
2 HOUR FIRE/SMOKE BARRIER
SMOKE BARRIER
SMOKE PARTITION
1 HOUR FIRE/SMOKE BARRIER
3 HOUR FIRE BARRIER
KEY NOTES
NEW HIRSCH ACCESS CONTROL PANEL.
NEW PIV READER. SEE E-503 FOR CONDUIT
REQUIREMENT.
3/4''C- 2 #12 + 1 #12EG
CONNECT TO EXISTING CIRCUIT IN TR ROOM.
TO HIRSCH ACCESS CONTROL PANEL. SEE
KEYNOTE 1 & ACCESS CONTROL RISER
DIAGRAM ON T-600 SERIES DRAWING.
1.
120VAC
J5
SCALE: 1/4" = 1' - 0"
NORTH
W.337.E-401
ELECTRICAL ENLARGED PLAN -
TR ROOM C1-5
0' 2' 4' 12'
SCALE: 1/4" = 1'-0"
Project Number
Campus / Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
F i t h U.S. Department of Veterans Affairs
B
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
Upgrade Server Room and Site Communication Infrastructure
11301 WILSHIRE BOULEVARD,
WEST LOS ANGELES, CA 90073
691-20-152FINAL CONSTRUCTION
DOCUMENTS
JULY 13, 2021 PM EW/JB
FULLY SPRINKLERED
A
GENERAL NOTES
ARCHITECT/ENGINEER OF RECORD
C
D
17075 Via Del Campo, San Diego, CA 92127
Phone: 858.946.0333
20801.11 20-SCE-06
GENERAL NOTE
FIRE PROTECTION
1. DO NOT MAKE ANY ATTACHMENTS OR MODIFICATIONS TO
ANY FIREPROOFED COMPONENTS.
SYMBOLS LIST
2 HOUR FIRE BARRIER
1 HOUR FIRE BARRIER
2 HOUR FIRE/SMOKE BARRIER
SMOKE BARRIER
SMOKE PARTITION
1 HOUR FIRE/SMOKE BARRIER
3 HOUR FIRE BARRIER
TR ROOM
C1-5
KEY NOTES
NEW HIRSCH ACCESS CONTROL PANEL.
NEW PIV READER. SEE E-503 FOR CONDUIT
REQUIREMENT.
3/4''C- 2 #12 + 1 #12EG
CONNECT TO EXISTING CIRCUIT IN TR ROOM.
TO HIRSCH ACCESS CONTROL PANEL. SEE
KEYNOTE 1 & ACCESS CONTROL RISER
DIAGRAM ON T-600 SERIES DRAWING.
1.
1LM-28
120VAC
J
SCALE: 1/4" = 1' - 0"
NORTH
W.345.E-401
ELECTRICAL ENLARGED PLAN -
TR ROOM 29 AND 39A
0' 2' 4' 12'
SCALE: 1/4" = 1'-0"
TR ROOM
Project Number
Campus / Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
F i t h U.S. Department of Veterans Affairs
B
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
Key Plan
Upgrade Server Room and Site Communication Infrastructure
11301 WILSHIRE BOULEVARD,
WEST LOS ANGELES, CA 90073
691-20-152FINAL CONSTRUCTION
DOCUMENTS
JULY 13, 2021 PM EW/JB
FULLY SPRINKLERED
A
GENERAL NOTES
ARCHITECT/ENGINEER OF RECORD
C
D
17075 Via Del Campo, San Diego, CA 92127
Phone: 858.946.0333
20801.11 20-SCE-06
GENERAL NOTE
FIRE PROTECTION
1. DO NOT MAKE ANY ATTACHMENTS OR MODIFICATIONS TO
ANY FIREPROOFED COMPONENTS.
SYMBOLS LIST
2 HOUR FIRE BARRIER
1 HOUR FIRE BARRIER
2 HOUR FIRE/SMOKE BARRIER
SMOKE BARRIER
SMOKE PARTITION
1 HOUR FIRE/SMOKE BARRIER
3 HOUR FIRE BARRIER
KEY NOTES
SCALE: 1/4" = 1' - 0"
NORTH
TR ROOM
39A
NEW HIRSCH ACCESS CONTROL PANEL.
NEW PIV READER. SEE E-503 FOR CONDUIT
REQUIREMENT.
3/4''C- 2 #12 + 1 #12EG
CONNECT TO EXISTING CIRCUIT IN TR ROOM.
TO HIRSCH ACCESS CONTROL PANEL. SEE
KEYNOTE 1 & ACCESS CONTROL RISER
DIAGRAM ON T-600 SERIES DRAWING.
1.
J
J
SCALE: 1/4" = 1' - 0"
NORTH
W.401.E-401
Project Number
Campus / Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
F i t h U.S. Department of Veterans Affairs
B
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
Upgrade Server Room and Site Communication Infrastructure
11301 WILSHIRE BOULEVARD,
WEST LOS ANGELES, CA 90073
691-20-152FINAL CONSTRUCTION
DOCUMENTS
JULY 13, 2021 PM EW/JB
FULLY SPRINKLERED
A
GENERAL NOTES
ARCHITECT/ENGINEER OF RECORD
C
D
17075 Via Del Campo, San Diego, CA 92127
Phone: 858.946.0333
20801.11 20-SCE-06
GENERAL NOTE
FIRE PROTECTION
1. DO NOT MAKE ANY ATTACHMENTS OR MODIFICATIONS TO
ANY FIREPROOFED COMPONENTS.
SYMBOLS LIST
2 HOUR FIRE BARRIER
1 HOUR FIRE BARRIER
2 HOUR FIRE/SMOKE BARRIER
SMOKE BARRIER
SMOKE PARTITION
1 HOUR FIRE/SMOKE BARRIER
3 HOUR FIRE BARRIER
0' 2' 4' 12'
SCALE: 1/4" = 1'-0"
SCALE: 1/4" = 1' - 0"
NORTH
TR ROOM
TR ROOM
KEY NOTES
NEW HIRSCH ACCESS CONTROL PANEL.
NEW PIV READER. SEE E-503 FOR CONDUIT
REQUIREMENT.
3/4''C- 2 #12 + 1 #12EG
CONNECT TO EXISTING CIRCUIT IN TR ROOM.
TO HIRSCH ACCESS CONTROL PANEL. SEE
KEYNOTE 1 & ACCESS CONTROL RISER
DIAGRAM ON T-600 SERIES DRAWING.
1.
2.
A239
A100G
J 64
J 6
W.402.E-401
Project Number
Campus / Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
F i t h U.S. Department of Veterans Affairs
B
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
Key Plan
Upgrade Server Room and Site Communication Infrastructure
11301 WILSHIRE BOULEVARD,
WEST LOS ANGELES, CA 90073
691-20-152FINAL CONSTRUCTION
DOCUMENTS
JULY 13, 2021 PM EW/JB
FULLY SPRINKLERED
A
GENERAL NOTES
ARCHITECT/ENGINEER OF RECORD
C
D
17075 Via Del Campo, San Diego, CA 92127
Phone: 858.946.0333
20801.11 20-SCE-06
GENERAL NOTE
FIRE PROTECTION
1. DO NOT MAKE ANY ATTACHMENTS OR MODIFICATIONS TO
ANY FIREPROOFED COMPONENTS.
SYMBOLS LIST
2 HOUR FIRE BARRIER
1 HOUR FIRE BARRIER
2 HOUR FIRE/SMOKE BARRIER
SMOKE BARRIER
SMOKE PARTITION
1 HOUR FIRE/SMOKE BARRIER
3 HOUR FIRE BARRIER
0' 2' 4' 12'
SCALE: 1/4" = 1'-0"
KEY NOTES
NEW HIRSCH ACCESS CONTROL PANEL.
NEW PIV READER. SEE E-503 FOR CONDUIT
REQUIREMENT.
3/4''C- 2 #12 + 1 #12EG
CONNECT TO EXISTING CIRCUIT IN TR ROOM.
TO HIRSCH ACCESS CONTROL PANEL. SEE
KEYNOTE 1 & ACCESS CONTROL RISER
DIAGRAM ON T-600 SERIES DRAWING.
NEW J-BOX ABOVE DOOR. SEE DETAIL 7
DRAWING 503.
SCALE: 1/4" = 1' - 0"
NORTH
TR ROOM
SCALE: 1/4" = 1' - 0"
NORTH
TR ROOM
1.
2.
RAMP UP
(EX)
GCR3
(EX)
GCR
(EX)
GXE-A
(EX)
GXE-B
(EX)
GXE A
(EX)
GXE UPS2
(EX)
GXE-B
DATA RACK
TO REMAIN
SECURITY
PANEL TO
REMIAN
6 5.1 5 4.2 4.1 4 3 2.1
K
X.G
X.H
L
X.J
X.K
L.1
M
N
N.1
SCALE: 1/4" = 1' - 0"
NORTH
W.500.E-401
Project Number
Campus / Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
F i t h
U.S. Department of Veterans Affairs
B
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
Key Plan
Upgrade Server Room and Site Communication Infrastructure
11301 WILSHIRE BOULEVARD,
WEST LOS ANGELES, CA 90073
691-20-152FINAL CONSTRUCTION
DOCUMENTS
JULY 13, 2021 PM EW/JB
FULLY SPRINKLERED
A
GENERAL NOTES
KEY NOTES
ARCHITECT/ENGINEER OF RECORD
C
D
17075 Via Del Campo, San Diego, CA 92127
Phone: 858.946.0333
20801.11 20-SCE-06
GENERAL NOTE
FIRE PROTECTION
1. DO NOT MAKE ANY ATTACHMENTS OR MODIFICATIONS TO
ANY FIREPROOFED COMPONENTS.
SYMBOLS LIST
2 HOUR FIRE BARRIER
1 HOUR FIRE BARRIER
2 HOUR FIRE/SMOKE BARRIER
SMOKE BARRIER
SMOKE PARTITION
1 HOUR FIRE/SMOKE BARRIER
3 HOUR FIRE BARRIER
0' 2' 4' 8'
SCALE: 1/4" = 1'-0"
EXISTING 80KVA UPS WITH BATTERY CABINETS TO
BE DISCONNECTED AND REMOVED AFTER NEW UPS
AND MCR IS COMMISSIONED.
EXISTING ELECTRICAL PANEL TO BE
DISCONNECTED AND REMOVED AFTER NEW UPS
AND MCR IS COMMISSIONED. REMOVE CIRCUIT
BREAKERS FROM EACH PANEL & TURN IT OVER
TO VA ELECTRICAL SHOP BEFORE DISPOSING
OFF PANEL.
EXISTING POWER (RECEPTACLES) TO IT RACKES TO
BE DISCONNECTED AND REMOVED AFTER NEW UPS
AND MCR IS COMMISSIONED. REMOVE EXISTING
BRANCH CIRCUIT ALL THE WAY TO ELECTRICAL
PANEL.
EXISTING POWER (RECEPTACLES) TO SERVER
CABINET TO BE DISCONNECTED AND REMOVED
AFTER NEW UPS AND MCR IS COMMISSIONED.
REMOVE EXISTING BRANCH CIRCUIT ALL THE WAY
TO ELECTRICAL PANEL.
ALL EXISTING ACTIVE EQUIPMENT SUCH AS
CISCO SWITCHES, SERVER, FIBER PATCH PANEL
WILL BE REMOVED/RELOCATED BY VA/OIT
DEPARTMENT.
ALL PATCH PANEL TO BE REMOVED OFFSITE BY IT
CABLING CONTRACTOR.
1.
2.
SCALE: NO SCALE
SCALE: NO SCALE
ELECTRICAL PANELS TO BE REMOVED
SCALE: NO SCALE
ELECTRICAL PANEL/ CONDUIT/ SO CORD
TO BE REMOVED
SCALE: NO SCALE
ELECTRICAL PANELS TO BE REMOVED
SCALE: NO SCALE
ELECTRICAL PANEL & SO CORD TO
RACKS TO BE REMOVED
SCALE: NO SCALE
TYPE SO CORDS TO DATA RACK TO BE
REMOVED
DN
5.1 5 4.2 4.1 4 3 2.1 2
K
X.G
X.H
L
X.J
X.K
L.1
M
N
N.1
SCALE: 1/4" = 1' - 0" NORTH
W.500.E-402
Project Number
Campus / Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
F i t h
U.S. Department of Veterans Affairs
B
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
Upgrade Server Room and Site Communication Infrastructure
11301 WILSHIRE BOULEVARD,
WEST LOS ANGELES, CA 90073
691-20-152FINAL CONSTRUCTION
DOCUMENTS
JULY 13, 2021 PM EW/JB
FULLY SPRINKLERED
A
GENERAL NOTES
KEY NOTES
ARCHITECT/ENGINEER OF RECORD
C
D
17075 Via Del Campo, San Diego, CA 92127
Phone: 858.946.0333
20801.11 20-SCE-06
GENERAL NOTE
FIRE PROTECTION
1. DO NOT MAKE ANY ATTACHMENTS OR MODIFICATIONS TO
ANY FIREPROOFED COMPONENTS.
SYMBOLS LIST
2 HOUR FIRE BARRIER
1 HOUR FIRE BARRIER
2 HOUR FIRE/SMOKE BARRIER
SMOKE BARRIER
SMOKE PARTITION
1 HOUR FIRE/SMOKE BARRIER
3 HOUR FIRE BARRIER
0' 2' 4' 8'
SCALE: 1/4" = 1'-0"
EXISTING FIXTURES (LOWER CEILING) TO BE DISCONNECTED
AND REMOVED. REMOVE EXISTING CIRCUIT ALL THE WAY TO
SOURCE PANEL.
EXISTING FIXTURES (HIGH BAY) TO BE DISCONNECTED AND
REMOVED. REMOVE CIRCUIT WIRE AND WIREWAY TO THE
CLOSEST HOMERUN J-BOX. ALL ASSOCIATED UNISTRUT
SUPPORT AND WIREWAY TO BE REMOVED. SEE PHOTO A.
INDICATES EXISTING CIRCUIT GLD1-19 AND SWITCH LEG “h”.
INDICATES EXISTING CIRCUIT GLD1-3 AND SWITCH LEG “g”.
WIREWAY WITH CIRCUIT GLD1-19 TO BE REMOVED.
WIREWAY WITH CIRCUIT GLD1-3 TO BE REMOVED.
EXISTING FIXTURES TO REMAIN AND RECONNECTED TO
CLOSEST EXISTING CIRCUIT GLD1-3g.
EXISTING FIXTURE TO REMAIN.
EXISTING LIGHT SWITCH Sg AND Sh TO REMAIN OPERATIVE.
REWIRE AS NECESSARY TO KEEP ACTIVE FIXTURES (TO
REMAIN) ON SWITCH LEG g AND h.
SCALE: NONE
GENERAL NOTES FOR PHOTO A
KEY NOTES FOR PHOTO A
DOWN STREAM FIXTURE TO BE RECONNECTED SO CIRCUITS TO
REMAINING FIXTURE IS RE-STORED.
A TYPICAL FIXTURE TO BE DISCONNECTED AND REMOVED IN THE
AREA SHOWN IN DETAIL 1 .
TYPICAL UNISTRUT SUPPORT TO BE REMOVED IN AREA
SHOWN.
TYPICAL WIRE GUTTER TO BE REMOVED ALONG WITH BRANCH
CIRCUIT WIRE IN AREA SHOWN.
B
C
C
A
B
DN
6 5.1 5 4.2 4.1 4 3 2.1
K
X.G
X.H
L
X.J
X.K
L.1
M
N
N.1
SCALE: 1/4" = 1' - 0" NORTH
W.500.E-403
Project Number
Campus / Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
F i t h
U.S. Department of Veterans Affairs
B
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
Key Plan
Upgrade Server Room and Site Communication Infrastructure
11301 WILSHIRE BOULEVARD,
WEST LOS ANGELES, CA 90073
691-20-152FINAL CONSTRUCTION
DOCUMENTS
JULY 13, 2021 PM EW/JB
FULLY SPRINKLERED
A
GENERAL NOTES
KEY NOTES
ARCHITECT/ENGINEER OF RECORD
C
D
17075 Via Del Campo, San Diego, CA 92127
Phone: 858.946.0333
20801.11 20-SCE-06
GENERAL NOTE
FIRE PROTECTION
1. DO NOT MAKE ANY ATTACHMENTS OR MODIFICATIONS TO
ANY FIREPROOFED COMPONENTS.
SYMBOLS LIST
2 HOUR FIRE BARRIER
1 HOUR FIRE BARRIER
2 HOUR FIRE/SMOKE BARRIER
SMOKE BARRIER
SMOKE PARTITION
1 HOUR FIRE/SMOKE BARRIER
3 HOUR FIRE BARRIER
0' 2' 4' 8'
SCALE: 1/4" = 1'-0"
EXISTING TWO STACKED CABLE TRAY TO BE REMOVED AFTER
ALL EXISTING COPPER, FIBER & POWER CABLES HAVE BEEN
REMOVED ONCE NEW MCR IS COMMISSIONED.
MBC(BATTERY)(UPS)
EXISTING
SLAB
PDU
DN
C R
C
U
N I T
DATA RACK
TO REMAIN
(CCTV)
SECURITY
PANEL
TO
REMIAN
C R
I T
U P
S
A
B A
T
P D
U
COLUMN
HDAHDA
HDAHDA
HDA HDA
C R
I T
C R
I T
RPMCRE-1
RPMCRE-3
RPMCRE-3
RPMCRE-3
RPMCRE-3
RPMCRE-1
UST 2
UST 3
UST 2
UST 3
MBC
U P
S
B
B A
T
P D
U
A-1
A-2A-3A-4A-5A-6A-7A-8A-9A-10A-11
A-12
B-1
B-2B-3B-4B-5B-6B-7B-8B-9B-10B-11
B-12
C-1C-2C-3C-4C-5C-6C-7C-8C-9C-10C-11
PB PB
FUTURE
BATTERY
CABINET
MBC
FUTURE
BATTERY
CABINET
RPMCRE-7
RPMCRE-5
6 4
URPMCRA-2,4,6
URPMCREA-5
URPMCRA-9
NEW HIRSCH PANEL FOR
TR ROOM SW RISER
3/4''C- 2 #12 + 1
#12EG
3/4''C- 2 #12 +
1 # 12 EG
RPMCRA-14,16,18
RPMCRA-8,10,12
EDBMCR-B-3
EDBMCR-A-3EDBMCR-A-3
EDBMCR-B-1
RPMCRE-8
0240C
MCR
0240D
NEW UPS ROOM
0240B
OIT
OFFICE
OIT OFFICE
ELECTRICAL
ROOM
OFFICE SUPPLY
WAREHOUSE
0262B
SPD
WAREHOUSE
0262E
MATERIALS
MANAGMENT
WAREHOUSE
VIEWVING
ROOM
0243A
MATERIALS
MANAGMENT
OFFICE
(LOGISTICS)
MATERIALS
MANAGMENT
OFFICE
(LOGISTICS)
0243B
URPMCRB-5
URPMCR A-11
URPMCRA-15
URPMCRB-1
URPMCRB-3
URPMCRA-13
URPMCRA-17
URPMCRB-7
URPMCRA-11
URPMCRA-11
URPMCRB-7
URPMCRB-4
URPMCRB-2
RPMCRE-10,12
RPMCRE-5
RPMCRE-9
RPMCRE-7
RPMCRE-5RPMCRE-9
T
6 5.1 5 4.2 4.1 4 3 2.1
K
X.G
X.H
L
X.J
X.K
L.1
M
N
N.1
W.500.E-404
SCALE: 1/2'' = 1'-0''
NEW 800A 480/277V ATS WITH BYPASS 4 POLE SYSTEM A.
NEW 800A 480/277V ATS WITH MANUAL BYPASS 4 POLE
SYSTEM B.
NEW 800A 480/277V EMERGENCY DISTRIBUTION BOARD
SYSTEM A EDBMCR-A.
NEW 800A 480/277V EMERGENCY DISTRIBUTION BOARD
SYSTEM B EDBMCR-B.
NEW 225A 480/277V EMERGENCY PANEL LMCRE.
NEW 75KVA 480-208/120V TRANSFORMER T-RPMCRE.
NEW 225A 208/120V EMERGENCY PANEL RPMCRE.
NEW 4 POST IT RACKS.
NEW SERVER CABINETS CHATSWORTH CAT#
FFIN-IICC-E72B. WITH EXHAUST RISER.
NEW 150 KVA 480V IN, 480V OUT UPS WITH BATTERY
CABINET SYSTEM A. (LITHIUM ION BATTERY)
NEW 150 KVA 480V IN, 480V OUT UPS WITH BATTERY
CABINET SYSTEM B. (LITHIUM ION BATTERY)
PLUG IN BUS DUCT SYSTEM A 200A 208/120V 3P 4W.
(STARLINE OR EQUAL).
PLUG IN BUS DUCT SYSTEM B 200A 208/120 3P 4W.
(STARLINE OR EQUAL).
TELECOMMUNICATIONS MAIN GROUND BUS. SEE DETAILS
ON E-501.
SERVER CABINET ROW SIGN ''A''.
SERVER CABINET ROW SIGN ''B''.
MDA DATA RACKS ROW SIGN ''C''.
3/4''C - 3 #12 H + 3 #12 N + 1 #12 EG.
UPS SYSTEM A PANEL URPMCRA 100A 208/120.
UPS SYSTEM B PANEL URPMCRB 100A 208/120.
NEW FIRE RATED TELEPHONE BACKBOARD 8'-0" HIGH. DO
NOT PAINT.
NEW HIRSCH ACCESS CONTROL PANEL.
NEW PIV READER. SEE E-503 FOR CONDUIT
REQUIREMENTS.
NEW 3/4''C- 2 # 12 + 1 # 12 EG.
TO NEW HIRSCH ACCESS CONTROL PANEL IN TR
ROOM SHOWN ON T-616 RISER DIAGRAM.
NEW J-BOX ABOVE DOOR SEE DETAIL 7 DRAWING
E-503.
NEW 3/4''C W/ PULL STRING BY ELECTRICAL
CONTRACTOR (INSTALLED ABOVE CEILING)
DOOR CONTROL CABLE BY SECURITY
CONTRACTOR.
NEW 100A/3P 480V DISCONNECT.
NEW 1 1/ 4''C- 3 # 2 + 1 #8EG.
NEW 3/ 4''C - 3 # 2 + 1 #12EG.
NEW 30A/3P DISCONNECT.
SCALE: 1/4" = 1' - 0" NORTH
0' 2' 4' 8'
SCALE: 1/4" = 1'-0"
Project Number
Campus / Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
F i t h U.S. Department of Veterans Affairs
B
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
Upgrade Server Room and Site Communication Infrastructure
11301 WILSHIRE BOULEVARD,
WEST LOS ANGELES, CA 90073
691-20-152FINAL CONSTRUCTION
DOCUMENTS
JULY 13, 2021 PM EW/JB
FULLY SPRINKLERED
A
GENERAL NOTES
ARCHITECT/ENGINEER OF RECORD
C
D
17075 Via Del Campo, San Diego, CA 92127
Phone: 858.946.0333
20801.11 20-SCE-06
GENERAL NOTE
FIRE PROTECTION
1. DO NOT MAKE ANY ATTACHMENTS OR MODIFICATIONS TO
ANY FIREPROOFED COMPONENTS.
SYMBOLS LIST
2 HOUR FIRE BARRIER
1 HOUR FIRE BARRIER
2 HOUR FIRE/SMOKE BARRIER
SMOKE BARRIER
SMOKE PARTITION
1 HOUR FIRE/SMOKE BARRIER
3 HOUR FIRE BARRIER
KEY NOTES
MAIN GROUND BUS. CONNECT TO
BUILDING GROUND BUS/ROD AT
UST 2 AND UST 3 ON BASEMENT
LEVEL. USE 1 # 4/0 BARE COPPER
CONDUCTOR. SEE DETAIL PN
E-502.
FOR SINGLE LINE SEE E-600 SERIES DRAWINGS.
FOR PANEL SCHEDULE SEE E-800 SERIES
DRAWINGS.
FOR PANEL LOCATION SEE. RESPECTIVE
OVERALL FLOOR PLAN.
ALL EXISTING LIGHTING FIXTURES TO BE
REMOVED AND REPLACED WITH NEW PER PLANS.
EXISTING CIRCUIT REPLACE EXISTING SWITCH
WITH WALL MOUNTED OCCUPANCY SENSOR TO
BE REUSED AND EXTEND TO NEW LIGHTS.
CONNECT NEW SMOKE DETECTOR TO EXISTING
FA SYSTEM.
CONTRACTOR SHALL TRACE EXISTING
RECEPTACLE IN EACH TR ROOM TO PANEL &
CIRCUIT NUMBER. INSTALL NEW SS COVER WITH
ENGRAVED GEN PANEL/ CIRCUIT NUMBER.
PROVIDE 120VAC TO NEW DDC I/O PANEL FROM
EXISTING 120VAC RECEPTACLE CIRCUIT IN TR.
COORDINATE WITH MECHANICAL CONTRACTOR
ON THE EXACT LOCATION OF DDC I/O PANEL.
1.
2.
3.
4.
5.
6.
7.
MCR
NEW UPS
ROOM
COLUMN
LMCRE-5
a b a b a b a
LMCRE-1
LMCRE-5
b
LMCRE-1
LMCRE-3
LMCRE-5
LMCRE-5
LMCRE-5
LMCRE-5
0240C
MCR
OIT OFFICE
0240A
ELECTRICAL
ROOM
0262B
SPD
WAREHOUSE
0262E
MATERIALS
MANAGMENT
WAREHOUSE
VIEWVING
ROOM
0243A
MATERIALS
MANAGMENT
OFFICE
(LOGISTICS)
MATERIALS
MANAGMENT
OFFICE
(LOGISTICS)
0243B
LMCRE-5
LMCRE-3
LMCRE-5
LMCRE-7
LMCRE-5
LMCRE-5
LMCRE-5
LMCRE-5
LMCRE-5
LMCRE-5
LMCRE-5
0240B
OIT
OFFICE
OFFICE SUPPLY
WAREHOUSE
6 5.1 5 4.2 4.1 4 3 2.1
K
X.G
X.H
L
X.J
X.K
L.1
M
N
N.1
W.500.E-405
SCALE: 1/4" = 1' - 0" NORTH
0' 2' 4' 8'
SCALE: 1/4" = 1'-0"
Project Number
Campus / Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
F i t h
U.S. Department of Veterans Affairs
B
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
Key Plan
Upgrade Server Room and Site Communication Infrastructure
11301 WILSHIRE BOULEVARD,
WEST LOS ANGELES, CA 90073
691-20-152FINAL CONSTRUCTION
DOCUMENTS
JULY 13, 2021 PM EW/JB
FULLY SPRINKLERED
A
GENERAL NOTES
KEY NOTES
ARCHITECT/ENGINEER OF RECORD
C
D
17075 Via Del Campo, San Diego, CA 92127
Phone: 858.946.0333
20801.11 20-SCE-06
GENERAL NOTE
FIRE PROTECTION
1. DO NOT MAKE ANY ATTACHMENTS OR MODIFICATIONS TO
ANY FIREPROOFED COMPONENTS.
SYMBOLS LIST
2 HOUR FIRE BARRIER
1 HOUR FIRE BARRIER
2 HOUR FIRE/SMOKE BARRIER
SMOKE BARRIER
SMOKE PARTITION
1 HOUR FIRE/SMOKE BARRIER
3 HOUR FIRE BARRIER
NEW EMERGENCY PANEL LMCRE 225A 480/277V
COLUMN
CT WALL SUPPORT
BRACK (TYP)
0240C
MCR
OIT OFFICE
0240A
ELECTRICAL
ROOM
0262B
SPD
WAREHOUSE
0262E
MATERIALS
MANAGMENT
WAREHOUSE
VIEWVING
ROOM
0243A
MATERIALS
MANAGMENT
OFFICE
(LOGISTICS)
MATERIALS
MANAGMENT
OFFICE
(LOGISTICS)
0243B
CABLE RISES TO INTERSTITIAL
LEVEL CABLE TRAY
0240B
OIT
OFFICE
OFFICE SUPPLY
WAREHOUSE
6 5.1 5 4.2 4.1 4 3 2.1
K
X.G
X.H
L
X.J
X.K
L.1
M
N
N.1
W.500.E-406
0' 2' 4' 8'
SCALE: 1/4" = 1'-0"
Project Number
Campus / Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
F i t h
U.S. Department of Veterans Affairs
B
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
Upgrade Server Room and Site Communication Infrastructure
11301 WILSHIRE BOULEVARD,
WEST LOS ANGELES, CA 90073
691-20-152FINAL CONSTRUCTION
DOCUMENTS
JULY 13, 2021 PM EW/JB
FULLY SPRINKLERED
A
GENERAL NOTES
KEY NOTES
ARCHITECT/ENGINEER OF RECORD
C
D
17075 Via Del Campo, San Diego, CA 92127
Phone: 858.946.0333
20801.11 20-SCE-06
GENERAL NOTE
FIRE PROTECTION
1. DO NOT MAKE ANY ATTACHMENTS OR MODIFICATIONS TO
ANY FIREPROOFED COMPONENTS.
SYMBOLS LIST
2 HOUR FIRE BARRIER
1 HOUR FIRE BARRIER
2 HOUR FIRE/SMOKE BARRIER
SMOKE BARRIER
SMOKE PARTITION
1 HOUR FIRE/SMOKE BARRIER
3 HOUR FIRE BARRIER
SCALE: 1/4" = 1' - 0" NORTH
UPPER TIER NEW 18" X 6" BASKET TYPE CABLE
TRAY FOR PHILIPS MM(OM4) FIBER & LOWER
TIER FOR FIBER TO TR ROOMS UNDER ANOTHER
PROJECT.
TWO NEW 18" W X 6" BASKET TYPE CABLE
TRACK STACKED. LOWER STAYS IN MCR AND
OIT ROOM. UPPER CONNECTS TO CABLE TRAY
AT INTERSTITIAL LEVEL.
TWO 12''W X 6''H BASKET TYPE CABLE TRAY
STACKED & STAGGERED. SEE SECTION
DETAIL 1 T-505.
TWO 12''W X 6''H BASKET TYPE CABLE TRAY
STACKED.
18'' X 6''H BASKET CABLE TRAY 10'-0'' TO
BOTTOM.
FIRE RATED TELEPHONE BACKBOARD 8'-0'' HIGH.
GAE-14
120VAC
GAE-16
120VAC
120VAC
GBE-14
W.500.E-407
ELECTRICAL ENLARGED PLAN -
TR ROOM 10SJ, 10SO, 10SA, 10IN,
10IS
0' 2' 4' 12'
SCALE: 1/4" = 1'-0"
Project Number
Campus / Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
F i t h
U.S. Department of Veterans Affairs
B
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
Key Plan
Upgrade Server Room and Site Communication Infrastructure
11301 WILSHIRE BOULEVARD,
WEST LOS ANGELES, CA 90073
691-20-152FINAL CONSTRUCTION
DOCUMENTS
JULY 13, 2021 PM EW/JB
FULLY SPRINKLERED
A
GENERAL NOTES
KEY NOTES
ARCHITECT/ENGINEER OF RECORD
C
D
17075 Via Del Campo, San Diego, CA 92127
Phone: 858.946.0333
20801.11 20-SCE-06
GENERAL NOTE
FIRE PROTECTION
1. DO NOT MAKE ANY ATTACHMENTS OR MODIFICATIONS TO
ANY FIREPROOFED COMPONENTS.
SYMBOLS LIST
2 HOUR FIRE BARRIER
1 HOUR FIRE BARRIER
2 HOUR FIRE/SMOKE BARRIER
SMOKE BARRIER
SMOKE PARTITION
1 HOUR FIRE/SMOKE BARRIER
3 HOUR FIRE BARRIER
NEW HIRSCH ACCESS CONTROL PANEL.
NEW PIV READER. SEE E-503 FOR CONDUIT
REQUIREMENTS.
NEW 3/4''C- 2 # 12 + 1 # 12 EG.
TO NEW HIRSCH ACCESS CONTROL PANEL IN
TR ROOM SHOWN ON T-616 RISER DIAGRAM.
NEW J-BOX ABOVE DOOR SEE DETAIL 7
DRAWING E-503.
NEW 3/4''C W/ PULL STRING BY ELECTRICAL
CONTRACTOR (INSTALLED ABOVE CEILING)
DOOR CONTROL CABLE BY SECURITY
CONTRACTOR.
SCALE: 1/4" = 1' - 0"
NORTH
ELECTRICAL
ENLARGED PLAN - ROOM 10SJ
SCALE: 1/4" = 1' - 0"
NORTH
ELECTRICAL
ENLARGED PLAN - ROOM 10SO
SCALE: 1/4" = 1' - 0"
NORTH
ELECTRICAL
ENLARGED PLAN - ROOM 10SA
SCALE: 1/4" = 1' - 0"
NORTH
ELECTRICAL
ENLARGED PLAN - ROOM 10IS
TR ROOM
10IS
SCALE: 1/4" = 1' - 0"
NORTH
ELECTRICAL
ENLARGED PLAN - ROOM 10IN
TR ROOM
10IN
TR ROOM
10 SJTR ROOM
10 SO
TR ROOM
10 SA
1.
STAIR
W.500.E-408
ELECTRICAL ENLARGED PLAN -
TR ROOM 11SH, 11SO, 11SN,
11SE, 11IN, 11IS
0' 2' 4' 12'
SCALE: 1/4" = 1'-0"
SCALE: 1/4" = 1' - 0"
NORTH
ELECTRICAL
ENLARGED PLAN - ROOM 11SH
Project Number
Campus / Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
F i t h
U.S. Department of Veterans Affairs
B
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
Key Plan
Upgrade Server Room and Site Communication Infrastructure
11301 WILSHIRE BOULEVARD,
WEST LOS ANGELES, CA 90073
691-20-152FINAL CONSTRUCTION
DOCUMENTS
JULY 13, 2021 PM EW/JB
FULLY SPRINKLERED
A
GENERAL NOTES
KEY NOTES
ARCHITECT/ENGINEER OF RECORD
C
D
17075 Via Del Campo, San Diego, CA 92127
Phone: 858.946.0333
20801.11 20-SCE-06
GENERAL NOTE
FIRE PROTECTION
1. DO NOT MAKE ANY ATTACHMENTS OR MODIFICATIONS TO
ANY FIREPROOFED COMPONENTS.
SYMBOLS LIST
2 HOUR FIRE BARRIER
1 HOUR FIRE BARRIER
2 HOUR FIRE/SMOKE BARRIER
SMOKE BARRIER
SMOKE PARTITION
1 HOUR FIRE/SMOKE BARRIER
3 HOUR FIRE BARRIER
SCALE: 1/4" = 1' - 0"
NORTH
ELECTRICAL
ENLARGED PLAN - ROOM 11SO
SCALE: 1/4" = 1' - 0"
NORTH
ELECTRICAL
ENLARGED PLAN - ROOM 11SN
SCALE: 1/4" = 1' - 0"
NORTH
ELECTRICAL
ENLARGED PLAN - ROOM 11IS
TR ROOM
11IS
SCALE: 1/4" = 1' - 0"
NORTH
ELECTRICAL
ENLARGED PLAN - ROOM 11IN
TR ROOM
1444A
TR ROOM
1603A
TR ROOM
11 SO
TR ROOM
1444A
SCALE: 1/4" = 1' - 0"
NORTH
ELECTRICAL
ENLARGED PLAN - ROOM 11SE
TR ROOM
1.
NEW HIRSCH ACCESS CONTROL PANEL.
NEW PIV READER. SEE E-503 FOR CONDUIT
REQUIREMENTS.
NEW 3/4''C- 2 # 12 + 1 # 12 EG.
TO NEW HIRSCH ACCESS CONTROL PANEL IN
TR ROOM SHOWN ON T-616 RISER DIAGRAM.
NEW J-BOX ABOVE DOOR SEE DETAIL 7
DRAWING E-503.
NEW 3/4''C W/ PULL STRING BY ELECTRICAL
CONTRACTOR (INSTALLED ABOVE CEILING)
DOOR CONTROL CABLE BY SECURITY
CONTRACTOR.
STAIR
W.500.E-409
ELECTRICAL ENLARGED PLAN -
TR ROOM 12SE, 12SA, 12IN, 12IS
0' 2' 4' 12'
SCALE: 1/4" = 1'-0"
Project Number
Campus / Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
F i t h
U.S. Department of Veterans Affairs
B
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
Key Plan
Upgrade Server Room and Site Communication Infrastructure
11301 WILSHIRE BOULEVARD,
WEST LOS ANGELES, CA 90073
691-20-152FINAL CONSTRUCTION
DOCUMENTS
JULY 13, 2021 PM EW/JB
FULLY SPRINKLERED
A
GENERAL NOTES
KEY NOTES
ARCHITECT/ENGINEER OF RECORD
C
D
17075 Via Del Campo, San Diego, CA 92127
Phone: 858.946.0333
20801.11 20-SCE-06
GENERAL NOTE
FIRE PROTECTION
1. DO NOT MAKE ANY ATTACHMENTS OR MODIFICATIONS TO
ANY FIREPROOFED COMPONENTS.
SYMBOLS LIST
2 HOUR FIRE BARRIER
1 HOUR FIRE BARRIER
2 HOUR FIRE/SMOKE BARRIER
SMOKE BARRIER
SMOKE PARTITION
1 HOUR FIRE/SMOKE BARRIER
3 HOUR FIRE BARRIER
SCALE: 1/4" = 1' - 0"
NORTH
ELECTRICAL
ENLARGED PLAN - ROOM 12IS
TR ROOM
12IS
SCALE: 1/4" = 1' - 0"
NORTH
ELECTRICAL
ENLARGED PLAN - ROOM 12IN
TR ROOM
12IN
SCALE: 1/4" = 1' - 0"
NORTH
ELECTRICAL
ENLARGED PLAN - ROOM 12SA
TR ROOM
12SA
SCALE: 1/4" = 1' - 0"
NORTH
ELECTRICAL
ENLARGED PLAN - ROOM 12SE
TR ROOM
12SE
1.
NEW HIRSCH ACCESS CONTROL PANEL.
NEW PIV READER. SEE E-503 FOR CONDUIT
REQUIREMENTS.
NEW 3/4''C- 2 # 12 + 1 # 12 EG.
TO NEW HIRSCH ACCESS CONTROL PANEL IN
TR ROOM SHOWN ON T-616 RISER DIAGRAM.
NEW J-BOX ABOVE DOOR SEE DETAIL 7
DRAWING E-503.
NEW 3/4''C W/ PULL STRING BY ELECTRICAL
CONTRACTOR (INSTALLED ABOVE CEILING)
DOOR CONTROL CABLE BY SECURITY
CONTRACTOR.
5 6
W.500.E-410
ELECTRICAL ENLARGED PLAN -
TR ROOM 13SE, 13SA, 13IN, 13IS
0' 2' 4' 12'
SCALE: 1/4" = 1'-0"
Project Number
Campus / Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
F i t h
U.S. Department of Veterans Affairs
B
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
Key Plan
Upgrade Server Room and Site Communication Infrastructure
11301 WILSHIRE BOULEVARD,
WEST LOS ANGELES, CA 90073
691-20-152FINAL CONSTRUCTION
DOCUMENTS
JULY 13, 2021 PM EW/JB
FULLY SPRINKLERED
A
GENERAL NOTES
KEY NOTES
ARCHITECT/ENGINEER OF RECORD
C
D
17075 Via Del Campo, San Diego, CA 92127
Phone: 858.946.0333
20801.11 20-SCE-06
GENERAL NOTE
FIRE PROTECTION
1. DO NOT MAKE ANY ATTACHMENTS OR MODIFICATIONS TO
ANY FIREPROOFED COMPONENTS.
SYMBOLS LIST
2 HOUR FIRE BARRIER
1 HOUR FIRE BARRIER
2 HOUR FIRE/SMOKE BARRIER
SMOKE BARRIER
SMOKE PARTITION
1 HOUR FIRE/SMOKE BARRIER
3 HOUR FIRE BARRIER
SCALE: 1/4" = 1' - 0"
NORTH
ELECTRICAL
ENLARGED PLAN - ROOM 13IS
TR ROOM
13IS
SCALE: 1/4" = 1' - 0"
NORTH
ELECTRICAL
ENLARGED PLAN - ROOM 13IN
TR ROOM
13IN
SCALE: 1/4" = 1' - 0"
NORTH
ELECTRICAL
ENLARGED PLAN - ROOM 13SA
TR ROOM
13SA
SCALE: 1/4" = 1' - 0"
NORTH
ELECTRICAL
ENLARGED PLAN - ROOM 13SE
TR ROOM
13SE
1.
NEW HIRSCH ACCESS CONTROL PANEL.
NEW PIV READER. SEE E-503 FOR CONDUIT
REQUIREMENTS.
NEW 3/4''C- 2 # 12 + 1 # 12 EG.
TO NEW HIRSCH ACCESS CONTROL PANEL IN
TR ROOM SHOWN ON T-616 RISER DIAGRAM.
NEW J-BOX ABOVE DOOR SEE DETAIL 7
DRAWING E-503.
NEW 3/4''C W/ PULL STRING BY ELECTRICAL
CONTRACTOR (INSTALLED ABOVE CEILING)
DOOR CONTROL CABLE BY SECURITY
CONTRACTOR.
120VAC
4CE-25
120VAC
3 5
64AE-21
W.500.E-411
ELECTRICAL ENLARGED PLAN -
TR ROOM 14SE, 14SA, 14IN, 14IS
0' 2' 4' 12'
SCALE: 1/4" = 1'-0"
Project Number
Campus / Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
F i t h
U.S. Department of Veterans Affairs
B
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
Key Plan
Upgrade Server Room and Site Communication Infrastructure
11301 WILSHIRE BOULEVARD,
WEST LOS ANGELES, CA 90073
691-20-152FINAL CONSTRUCTION
DOCUMENTS
JULY 13, 2021 PM EW/JB
FULLY SPRINKLERED
A
GENERAL NOTES
KEY NOTES
ARCHITECT/ENGINEER OF RECORD
C
D
17075 Via Del Campo, San Diego, CA 92127
Phone: 858.946.0333
20801.11 20-SCE-06
GENERAL NOTE
FIRE PROTECTION
1. DO NOT MAKE ANY ATTACHMENTS OR MODIFICATIONS TO
ANY FIREPROOFED COMPONENTS.
SYMBOLS LIST
2 HOUR FIRE BARRIER
1 HOUR FIRE BARRIER
2 HOUR FIRE/SMOKE BARRIER
SMOKE BARRIER
SMOKE PARTITION
1 HOUR FIRE/SMOKE BARRIER
3 HOUR FIRE BARRIER
SCALE: 1/4" = 1' - 0"
NORTH
ELECTRICAL
ENLARGED PLAN - ROOM 14IS
TR ROOM
14IS
SCALE: 1/4" = 1' - 0"
NORTH
ELECTRICAL
ENLARGED PLAN - ROOM 14IN
SCALE: 1/4" = 1' - 0"
NORTH
ELECTRICAL
ENLARGED PLAN - ROOM 14SA
TR ROOM
14SA
SCALE: 1/4" = 1' - 0"
NORTH
ELECTRICAL
ENLARGED PLAN - ROOM 14SE
TR ROOM
14SE
TR ROOM
14IN
1.
NEW HIRSCH ACCESS CONTROL PANEL.
NEW PIV READER. SEE E-503 FOR CONDUIT
REQUIREMENTS.
NEW 3/4''C- 2 # 12 + 1 # 12 EG.
TO NEW HIRSCH ACCESS CONTROL PANEL IN
TR ROOM SHOWN ON T-616 RISER DIAGRAM.
NEW J-BOX ABOVE DOOR SEE DETAIL 7
DRAWING E-503.
NEW 3/4''C W/ PULL STRING BY ELECTRICAL
CONTRACTOR (INSTALLED ABOVE CEILING)
DOOR CONTROL CABLE BY SECURITY
CONTRACTOR.
W.500.E-412
ELECTRICAL ENLARGED PLAN -
TR ROOM 15SE, 15SA, 15IN, 15IS
0' 2' 4' 12'
SCALE: 1/4" = 1'-0"
SCALE: 1/4" = 1' - 0"
NORTH
ELECTRICAL
ENLARGED PLAN - ROOM 15IS
TR ROOM
15IS
Project Number
Campus / Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
F i t h U.S. Department of Veterans Affairs
B
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
Key Plan
Upgrade Server Room and Site Communication Infrastructure
11301 WILSHIRE BOULEVARD,
WEST LOS ANGELES, CA 90073
691-20-152FINAL CONSTRUCTION
DOCUMENTS
JULY 13, 2021 PM EW/JB
FULLY SPRINKLERED
A
GENERAL NOTES
KEY NOTES
ARCHITECT/ENGINEER OF RECORD
C
D
17075 Via Del Campo, San Diego, CA 92127
Phone: 858.946.0333
20801.11 20-SCE-06
GENERAL NOTE
FIRE PROTECTION
1. DO NOT MAKE ANY ATTACHMENTS OR MODIFICATIONS TO
ANY FIREPROOFED COMPONENTS.
SYMBOLS LIST
2 HOUR FIRE BARRIER
1 HOUR FIRE BARRIER
2 HOUR FIRE/SMOKE BARRIER
SMOKE BARRIER
SMOKE PARTITION
1 HOUR FIRE/SMOKE BARRIER
3 HOUR FIRE BARRIER
SCALE: 1/4" = 1' - 0"
NORTH
ELECTRICAL
ENLARGED PLAN - ROOM 15IN
TR ROOM
15IN
SCALE: 1/4" = 1' - 0"
NORTH
ELECTRICAL ENLARGED PLAN -
ROOM 15SA
TR ROOM
15SA
SCALE: 1/4" = 1' - 0"
NORTH
ELECTRICAL
ENLARGED PLAN - ROOM 15SE
TR ROOM
15SE
1.
NEW HIRSCH ACCESS CONTROL PANEL.
NEW PIV READER. SEE E-503 FOR CONDUIT
REQUIREMENTS.
NEW 3/4''C- 2 # 12 + 1 # 12 EG.
TO NEW HIRSCH ACCESS CONTROL PANEL IN
TR ROOM SHOWN ON T-616 RISER DIAGRAM.
NEW J-BOX ABOVE DOOR SEE DETAIL 7
DRAWING E-503.
NEW 3/4''C W/ PULL STRING BY ELECTRICAL
CONTRACTOR (INSTALLED ABOVE CEILING)
DOOR CONTROL CABLE BY SECURITY
CONTRACTOR.
STAIR
W.500.E-413
ELECTRICAL ENLARGED PLAN -
TR ROOM 16SA, 16SE, 16IN, 16IS
AND E2
0' 2' 4' 12'
SCALE: 1/4" = 1'-0"
SCALE: 1/4" = 1' - 0"
NORTH
ELECTRICAL
ENLARGED PLAN - ROOM 16IS
TR ROOM
16IS
Project Number
Campus / Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
F i t h U.S. Department of Veterans Affairs
B
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
Key Plan
Upgrade Server Room and Site Communication Infrastructure
11301 WILSHIRE BOULEVARD,
WEST LOS ANGELES, CA 90073
691-20-152FINAL CONSTRUCTION
DOCUMENTS
JULY 13, 2021 PM EW/JB
FULLY SPRINKLERED
A
GENERAL NOTES
KEY NOTES
ARCHITECT/ENGINEER OF RECORD
C
D
17075 Via Del Campo, San Diego, CA 92127
Phone: 858.946.0333
20801.11 20-SCE-06
GENERAL NOTE
FIRE PROTECTION
1. DO NOT MAKE ANY ATTACHMENTS OR MODIFICATIONS TO
ANY FIREPROOFED COMPONENTS.
SYMBOLS LIST
2 HOUR FIRE BARRIER
1 HOUR FIRE BARRIER
2 HOUR FIRE/SMOKE BARRIER
SMOKE BARRIER
SMOKE PARTITION
1 HOUR FIRE/SMOKE BARRIER
3 HOUR FIRE BARRIER
SCALE: 1/4" = 1' - 0"
NORTH
ELECTRICAL
ENLARGED PLAN - ROOM 16IN
TR ROOM
16IN
SCALE: 1/4" = 1' - 0"
NORTH
ELECTRICAL
ENLARGED PLAN - ROOM 16SA
TELECOM
RM 16SA
SCALE: 1/4" = 1' - 0"
NORTH
ELECTRICAL
ENLARGED PLAN - ROOM 16SE
TR ROOM
16SE
1.
SCALE: 1/4" = 1' - 0"
NORTH
ELECTRICAL ENLARGED PLAN -
PENTHOUSE TR ROOM E2
NEW HIRSCH ACCESS CONTROL PANEL.
NEW PIV READER. SEE E-503 FOR CONDUIT
REQUIREMENTS.
NEW 3/4''C- 2 # 12 + 1 # 12 EG.
TO NEW HIRSCH ACCESS CONTROL PANEL IN
TR ROOM SHOWN ON T-616 RISER DIAGRAM.
NEW J-BOX ABOVE DOOR SEE DETAIL 7
DRAWING E-503.
NEW 3/4''C W/ PULL STRING BY ELECTRICAL
CONTRACTOR (INSTALLED ABOVE CEILING)
DOOR CONTROL CABLE BY SECURITY
CONTRACTOR.
ROOF
COND
0240C MCR COND4
COND
0240C MCR COND3
COND
0240C MCR COND1
COND
0240C MCR COND2
COND
0240C UPS COND5
2 2 2
2 2
WP
GFIRPMCR-7
SCALE: 1/4" = 1' - 0"
NORTH
W.500.E-414
Project Number
Campus / Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
F i t h
U.S. Department of Veterans Affairs
B
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
Key Plan
Upgrade Server Room and Site Communication Infrastructure
11301 WILSHIRE BOULEVARD,
WEST LOS ANGELES, CA 90073
691-20-152FINAL CONSTRUCTION
DOCUMENTS
JULY 13, 2021 PM EW/JB
FULLY SPRINKLERED
A
GENERAL NOTES
KEY NOTES
ARCHITECT/ENGINEER OF RECORD
C
D
17075 Via Del Campo, San Diego, CA 92127
Phone: 858.946.0333
20801.11 20-SCE-06
GENERAL NOTE
FIRE PROTECTION
1. DO NOT MAKE ANY ATTACHMENTS OR MODIFICATIONS TO
ANY FIREPROOFED COMPONENTS.
SYMBOLS LIST
2 HOUR FIRE BARRIER
1 HOUR FIRE BARRIER
2 HOUR FIRE/SMOKE BARRIER
SMOKE BARRIER
SMOKE PARTITION
1 HOUR FIRE/SMOKE BARRIER
3 HOUR FIRE BARRIER
0' 2' 4' 12'
SCALE: 1/4" = 1'-0"
30A/ 3P 480V NEMA 3R FUSED DISCONNECT.
NEW 3/ 4''C - 3 # 12 + 1 # 12 EG.
PANEL ELMCRA-ROOF 100A 480V 3P 3W
NEMA 3R.
UNISTRUT RACK SEE DETAIL THIS SHEET.
NEW 3/4''C - 2 # 12 + 1 # 12 EG.
PANEL ELMCRB-ROOF 100A 480V 3P 3W NEMA 3R.
3/8'' DIA. KWIK BOLT 3 (2 1/2'' EMBEDMENT) 4 PER LEG
FITTING UNISTRUT CONNECTOR.
1/4'' DIA. BOLT.
(ESR 1917).
KEY NOTES FOR ELEVATION DETAIL:
NEW DISCONNECT.
POST BASE (P2073 UNISTRUT).
(1 5/8 x 1 5/8'') (P1001) (UNISTRUT).
(P1000 UNISTRUT).2
SCALE: NO SCALE
1. THE TWO FEEDER CONDUITS FOR THE TWO
PANELS & ONE BRANCH CIRCUIT CONDUIT SHALL
BE GROUPED TOGETHER & ROUTED WITH
MECHANICAL PIPES THROUGH NEW DOG HOUSE
FOR ROOF PENETRATION.
120VAC
SCALE: 1/4" = 1' - 0"
NORTH
W.506.E-401
ELECTRICAL ENLARGED PLAN -
ROOM 133
0' 2' 4' 12'
SCALE: 1/4" = 1'-0"
Project Number
Campus / Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
F i t h U.S. Department of Veterans Affairs
B
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
Key Plan
Upgrade Server Room and Site Communication Infrastructure
11301 WILSHIRE BOULEVARD,
WEST LOS ANGELES, CA 90073
691-20-152FINAL CONSTRUCTION
DOCUMENTS
JULY 13, 2021 PM EW/JB
FULLY SPRINKLERED
A
GENERAL NOTES
ARCHITECT/ENGINEER OF RECORD
C
D
17075 Via Del Campo, San Diego, CA 92127
Phone: 858.946.0333
20801.11 20-SCE-06
GENERAL NOTE
FIRE PROTECTION
1. DO NOT MAKE ANY ATTACHMENTS OR MODIFICATIONS TO
ANY FIREPROOFED COMPONENTS.
SYMBOLS LIST
2 HOUR FIRE BARRIER
1 HOUR FIRE BARRIER
2 HOUR FIRE/SMOKE BARRIER
SMOKE BARRIER
SMOKE PARTITION
1 HOUR FIRE/SMOKE BARRIER
3 HOUR FIRE BARRIER
KEY NOTES
NEW HIRSCH ACCESS CONTROL PANEL.
NEW PIV READER. SEE E-503 FOR CONDUIT
REQUIREMENT.
3/4''C- 2 #12 + 1 #12EG
CONNECT TO EXISTING CIRCUIT IN TR ROOM.
120VAC
SCALE: 1/4" = 1' - 0"
NORTH
W.507.E-401
ELECTRICAL ENLARGED PLAN -
TR ROOM 102
0' 2' 4' 12'
SCALE: 1/4" = 1'-0"
Project Number
Campus / Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
F i t h
U.S. Department of Veterans Affairs
B
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions:…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .