Attachment E - Conceptual Drawings.pdf
PDF 34 MB Posted
- Solicitation number
- BSA_RFP_396466
- Issued by
-
Department of Energy Office of Science
View the file
Other files
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Project Number
/6
/2
9:
:1
A
M C
:\r vt
\2
0\
-A
-B N
L- E
IC
_C
E N
TR
A
Lv
_T yl er .D ye
5.
rv t
HDR Architecture
10235960
HDR Arlington 3001 Washington Blvd, Suite 200
Arlington, VA 22201
Brookhaven National
Laboratory Upton, New York, Electron Ion Collider
Upton, New York
C o n c e p t
D e s ig n
R e v ie w S u b m it ta l
/0
6/
Concept Design 100% Review
Submittal 11/06/2020
1/
2" 1"
2"
NOT F
OR C
ONSTRUCTIO
N
PRELI
M
IN
ARY
Project Number
Original Issue
Sheet Number
Sheet Name
Project Status
Project Designer
Project Manager
Project Architect
Landscape Architect
Civil Engineer
Structural Engineer
Mechanical Engineer
Electrical Engineer
Interior Designer
Equipment Planner
Wayfinding
Sheet Reviewer
A
B
C
D
12345
A
B
C
D
Plumbing Engineer
09/25/2020 60% Review Submittal
11/06/2020 100% Review Submittal
/6
/2
3:
:0
P
M C
:\r vt
\2
0\
-A
-B N
L- E
IC
_C
E N
TR
A
Lv
_T yl er .D ye
5.
rv t
G-001
INDEX OF DRAWINGS
Brookhaven National Laboratory Electron Ion Collider
Concept Design 100% Review Submittal
Upton, New York
HDR Architecture
10235960
9/6/2019
HDR Arlington 3001 Washington Blvd, Suite 200 Arlington, VA 22201
Author
Gabriela Kleiman
Tyler Dye
Kevin LeMans
Joseph Dennis
Joseph Krzyzewski
Phil Beadle
Kelly Hartshorn
G-001s - Drawing Index
Sheet Number Sheet Name
14-MECHANICAL
M-100 MECHANICAL - SITE PLAN
M-101 MECHANICAL - PLAN - ALC 01
M-102 MECHANICAL - PLAN - B1002 & CRYO 1002
M-103 MECHANICAL - PLAN - ALC 03
M-104 MECHANICAL - PLAN - B1004
M-105 MECHANICAL - PLAN - ALC 05
M-106 MECHANICAL - PLAN - CRYO 1006
M-107 MECHANICAL - PLAN - ALC 07
M-109 MECHANICAL - PLAN - ALC 09
M-110 MECHANICAL - PLAN - B1010
M-111 MECHANICAL - PLAN - ALC 11
M-112 MECHANICAL - PLAN - B1012
M-601 MECHANICAL - DIAGRAM - ALC 01
M-602.1 MECHANICAL - DIAGRAM - B1002
M-602.2 MECHANICAL - DIAGRAM - CRYO 1002
M-602.3 MECHANICAL - DIAGRAM - TUNNEL 1002
M-603 MECHANICAL - DIAGRAM - ALC 03
M-604.1 MECHANICAL - DIAGRAM - B1004
M-604.2 MECHANICAL - DIAGRAM - TUNNEL 1004
M-605 MECHANICAL - DIAGRAM - ALC 05
M-606 MECHANICAL - DIAGRAM - CRYO 1006
M-607 MECHANICAL - DIAGRAM - ALC 07
M-609 MECHANICAL - DIAGRAM - ALC 09
M-610.1 MECHANICAL - DIAGRAM - B1010
M-610.2 MECHANICAL - DIAGRAM - CRYO 1010
M-610.3 MECHANICAL - DIAGRAM - TUNNEL 1010
M-611 MECHANICAL - DIAGRAM - ALC 11
M-612.1 MECHANICAL - DIAGRAM - B1012
M-612.2 MECHANICAL - DIAGRAM - TUNNEL 1012
15-ELECTRICAL
E-001 ELECTRICAL SYMBOLS AND ABBREVIATIONS
ES001 ELECTRICAL SITE PLAN - INFO
ES002 ELECTRICAL SITE PLAN
EL101 LIGHTING PLAN - LEVEL 1 - ALC-01
EL102 LIGHTING PLAN - LEVEL 1 - B1002
EL103 LIGHTING PLAN - LEVEL 2 - B1002
EL107 LIGHTING PLAN - LEVEL 1 - ALC-07
EL110 LIGHTING PLAN - LEVEL 1 - B1010 & DI WATER SYSTEM B1010-B
EL111 LIGHTING PLAN - LEVEL 2 - B1010 & DI WATER SYSTEM B1010-B
EP100 ELECTRICAL PLAN - BUILDING 638
EP101 ELECTRICAL PLAN - LEVEL 1 - ALC-01
EP102 ELECTRICAL PLAN - LEVEL 1 - B1002
EP103 ELECTRICAL PLAN - LEVEL 2 - B1002
EP107 ELECTRICAL PLAN - LEVEL 1 - ALC 07
EP110 ELECTRICAL PLAN - LEVEL 1 - B1010 & DI WATER SYSTEM B1010-B
EP111 ELECTRICAL PLAN - LEVEL 2 - B1010 & DI WATER SYSTEM B1010-B
EC101 COMMUNICATIONS AND DATA PLAN - LEVEL 1 - ALC-01
EC102 COMMUNICATIONSAND DATA PLAN - LEVEL 1 - B1002
EC103 COMMUNICATIONSAND DATA PLAN - LEVEL 2 - B1002
EC107 COMMUNICATIONS AND DATA PLAN - LEVEL 1 - ALC-07
EC110 COMMUNICATIONS AND DATA PLAN - LEVEL 1 - B1010 & DI WATER SYSTEM B1010-B
E-401 ELECTRICAL ENLARGED SITE PLAN - ALC-01
E-402 ELECTRICAL ENLARGED SITE PLAN - B1002 & CRYO B1002
E-403 ELECTRICAL ENLARGED SITE PLAN - ALC-03
E-404 ELECTRICAL ENLARGED SITE PLAN - B1004
E-405 ELECTRICAL ENLARGED SITE PLAN - ALC-05
E-406 ELECTRICAL ENLARGED SITE PLAN - CRYO 1006
E-407 ELECTRICAL ENLARGED SITE PLAN - ALC-07
E-409 ELECTRICAL ENLARGED SITE PLAN - ALC-09
E-410 ELECTRICAL ENLARGED SITE PLAN - B1010 & CRYO B1010
E-411 ELECTRICAL ENLARGED SITE PLAN - ALC-11
E-412 ELECTRICAL ENLARGED SITE PLAN - B1012
E-601 ELECTRICAL ONE-LINE DIAGRAM - B1010
E-602 ELECTRICAL SINGLE LINE DIAGRAM - B638
E-603 ELECTRICAL ONE-LINE DIAGRAM - B1010
E-604 ELECTRICAL ONE-LINE DIAGRAM - B1002
G-001s - Drawing Index
Sheet Number Sheet Name
01-GENERAL
G-000 COVER SHEET
G-001 INDEX OF DRAWINGS
G-100 LIFE SAFETY PLAN - ALC-01/03/09/11
G-101 LIFE SAFETY PLAN - B1002
G-102 LIFE SAFETY PLAN - B1004
G-103 LIFE SAFETY PLAN - ALC-05
G-104 LIFE SAFETY PLAN - CRYO 1002/06
G-105 LIFE SAFETY PLAN - ALC-07
G-106 LIFE SAFETY PLAN - B1010 - FIRST FLOOR
G-107 LIFE SAFETY PLAN - B1010 - SECOND FLOOR
G-108 LIFE SAFETY PLAN - CRYO 1010
G-109 LIFE SAFETY PLAN - B1012
05-CIVIL
C-100 EXISTING TOPOGRAPHY
C-101 PROPOSED SITE PLAN
C-102 SITE PLANS FOR THE PECONIC RIVER CORRIDOR AND BUFFER AREAS
C-103 OVERALL UTILITY PLAN
07-STRUCTURAL
S-001 GENERAL NOTES AND ABBREVIATIONS
S-002 SPECIAL INSPECTION AND SCHEDULES
S-100 FLOOR PLANS - ALC-01, ALC-03, ALC-09 & ALC-11 (STEEL BRACED FRAME OPTION)
S-100A FLOOR PLANS - ALC-01, ALC-03, ALC-09 & ALC-11 (CMU SHEAR WALL OPTION)
S-101 FLOOR PLANS - B1002 (STEEL BRACED FRAME OPTION)
S-101A FLOOR PLANS - B1002 (CMU SHEAR WALL OPTION)
S-103 FLOOR PLANS - B1004 (STEEL BRACED FRAME OPTION)
S-103A FLOOR PLANS - B1004 (CMU SHEAR WALL OPTION)
S-104 FLOOR PLANS - ALC-05 (STEEL BRACED FRAME OPTION)
S-104A FLOOR PLANS - ALC-05 (CMU SHEAR WALL OPTION)
S-105 FLOOR PLANS - CRYO 1002 AND CRYO 1006 (STEEL BRACED FRAME OPTION)
S-105A FLOOR PLANS - CRYO 1002 AND CRYO 1006 (CMU SHEAR WALL OPTION)
S-106 FLOOR PLANS - ALC-07 (STEEL BRACED FRAME OPTION)
S-106A FLOOR PLANS - ALC-07 (CMU SHEAR WALL OPTION)
S-107 FLOOR PLANS - B1010 (STEEL BRACED FRAME OPTION)
S-107A FLOOR PLANS - B1010 (CMU SHEAR WALL OPTION)
S-110 FLOOR PLANS - CRYO 1010 (STEEL BRACED FRAME OPTION)
S-110A FLOOR PLANS - CRYO 1010 (CMU SHEAR WALL OPTION)
S-111 FLOOR PLANS - B1012 (STEEL BRACED FRAME OPTION)
S-111A FLOOR PLANS - B1012 (CMU SHEAR WALL OPTION)
S-300 BUILDING SECTIONS
S-301 TYPICAL CONCRETE DETAILS
08-ARCHITECTURAL
A-100 FLOOR PLANS - ALC 01/03/09/11
A-101 SITE PLANS - ALC 09/11
A-102 SITE PLANS - B1002
A-103 FLOOR PLANS - B1002
A-104 FLOOR PLANS - B1004
A-105 FLOOR PLANS - ALC-05
A-106 SITE PLANS - B1006 ALTERNATE
A-107 FLOOR PLANS - CRYO 1002/1006
A-108 FLOOR PLANS - ALC 07
A-109 SITE PLANS - B1010
A-110 FIRST FLOOR PLAN - B1010
A-111 SECOND FLOOR PLAN - B1010
A-112 FLOOR PLANS - CRYO 1010
A-113 FLOOR PLANS - B1012
A-200 EXTERIOR ELEVATIONS - ALC 01/03/09/11
A-201 EXTERIOR ELEVATIONS - B1002
A-202 EXTERIOR ELEVATIONS - B1004
A-203 EXTERIOR ELEVATIONS - ALC 05
A-204 EXTERIOR ELEVATIONS - CRYO 1002/1006
A-205 EXTERIOR ELEVATIONS - ALC 07
A-206 EXTERIOR ELEVATIONS - B1010
A-207 EXTERIOR ELEVATIONS - CRY0 1010
A-208 EXTERIOR ELEVATIONS - B1012
A-300 BUILDING SECTIONS
MARK DATE DESCRIPTION
A-01
A-01
C-01
C-01
3-013-01
2-012-01
B-01
B-01
1-011-01
S P
R
IN
K L
E R
S T
A T
IO
N
F A
P L.
P O
W E
R D
IS
T
R
IB
U T
IO
N
B Y
P A
S S
S W
IT
C
H U
P S
FUTURE EXPANSION
VESTIBULE
ALC-S-A
RCS
POWER
SUPPLIES
ALC-S-B
ELECTRICAL
EQUIPMENT
ALC-S-D
CONTROLS
ELECTRONICS
ALC-S-C
COMMON PATH
50'-0"
T R
A V
E L
D
IS
T A
N C
E
9'
-0
TRAVEL DISTANCE
49'-0"
4-014-01
Room Legend
B
A B C
D
E
F
LIFE SAFETY LEGEND
TRAVEL DISTANCE
999'-11"
COMMON PATH
999'-11"999'-11"
TRAVEL DISTANCE: LONGEST ROUTE TO AN EXIT (MAXIMUM PER
SPACE/AREA SHOWN) (IBC 1017.2)
COMMON PATH: DISTANCE TRAVELED BEFORE AN EXIT PATH IS CHOSEN
(MAXIMUM PER SPACE/ AREA SHOWN) (IBC 1006.2)
EXIT
1/
2" 1"
2"
NOT F
OR C
ONSTRUCTIO
N
PRELI
M
IN
ARY
Project Number
Original Issue
Sheet Number
Sheet Name
Project Status
Project Designer
Project Manager
Project Architect
Landscape Architect
Civil Engineer
Structural Engineer
Mechanical Engineer
Electrical Engineer
Interior Designer
Equipment Planner
Wayfinding
Sheet Reviewer
A
B
C
D
12345
A
B
C
D
Plumbing Engineer
8' 16' 32'
09/25/2020 60% Review Submittal
11/06/2020 100% Review Submittal
/6
/2
:3 4:
A
M C
:\r vt
\2
0\
-A
-B N
L- E
IC
_C
E N
TR
A
Lv
_T yl er .D ye
5.
rv t
G-100
LIFE SAFETY PLAN -
ALC-01/03/09/11
Brookhaven National Laboratory Electron Ion Collider
Concept Design 100% Review Submittal
Upton, New York
HDR Architecture
10235960
09/16/20
HDR Arlington 3001 Washington Blvd, Suite 200 Arlington, VA 22201
Author
Gabriela Kleiman
Tyler Dye
Kevin LeMans
Joseph Dennis
Joseph Krzyzewski
Phil Beadle
Kelly Hartshorn
1/16" = 1'-0" A5
FIRST FLOOR LIFE SAFETY PLAN - ALC-01/03/09/11
UP
M-02
M-02
L-02
L-02
K-02
K-02
J-02
J-02
H-02
H-02
G-02
G-02
F-02
F-02
E-02
E-02
D-02
D-02
C-02
C-02
B-02
B-02
A-02
A-02
4-024-02
2-022-02
1-021-02
3-023-02
1-C02
1-C02
2-C02
2-C02
A-C02
A-C02
5-025-02
N-02
N-02
RCS SEPTUM RCS SEPTUM
MCC PA D.I SYSTEM
PUMPS 1 PUMPS 2
EXH-1 EXH-2 FILTERS
SPRINKLER
STATION
PAP EXPANSION
TANK
CONTROL
RACK
OPTICAL TABLES
PUMPS 3 PUMPS 4
EXH-3 EXH-4PAP EXPANSION
TANK
PA D.I SYSTEM
CONTROL
RACK
DI
WATER
SYSTEM
1002-B
RF
EQUIPMENT
ROOM
1002-C
CATHODE
FACTORY
1002-G
SWITCHGEAR
1002-F
CHILLER
ROOM
1002-M
GOWNING
1002-O
LASER
ROOM
1002-N
GUN
ROOM
1002-J
LOBBY
1002-I
RCS
SEPTUM
ROOM
1002-A
SERVICE
VESTIBULE
1002-H
ELEVATOR
CONTROLS
ELECTRONICS
1002-E
COMMON PATH
24'-0"
TRAVEL DISTANCE
156'-0"
C O
M M
O N
P A
T H
-0
MACHINE
ROOM
1002-K
C O
M M
O N
P A
'-0
TRAVEL DISTANCE
95'-0"
R A
C K
S
COMMON PATH
102'-0"
OFFICE
1002-D
STAIR
1002-V
M-02
M-02
L-02
L-02
K-02
K-02
J-02
J-02
H-02
H-02
G-02
G-02
F-02
F-02
E-02
E-02
D-02
D-02
C-02
C-02
B-02
B-02
A-02
A-02
4-024-02
2-022-02
1-021-02
3-023-02
1-C02
1-C02
2-C02
2-C02
A-C02
A-C02
5-025-02
N-02
N-02
ELEVATOR
LOBBY
SECOND
FLOOR
1002-L
POWER
SUPPLY
RACKS
1002-Q
CONTROLS
ELECTRONICS
1002-R
RF
SECOND
FLOOR
1002-T
TRAVEL DISTANCE
82'-0"
COMMON PATH
74'-0"
TRAVEL DISTANCE
148'-0"
Room Legend
B
ROOF
RESTROOM
1002-P
ROOF - EARTH
SHIELDING AT GRADE
STAIR
1002-W
STAIR
1002-U
LIFE SAFETY LEGEND
TRAVEL DISTANCE
999'-11"
COMMON PATH
999'-11"999'-11"
TRAVEL DISTANCE: LONGEST ROUTE TO AN EXIT (MAXIMUM PER
SPACE/AREA SHOWN) (IBC 1017.2)
COMMON PATH: DISTANCE TRAVELED BEFORE AN EXIT PATH IS CHOSEN
(MAXIMUM PER SPACE/ AREA SHOWN) (IBC 1006.2)
EXIT
1/
2" 1"
2"
NOT F
OR C
ONSTRUCTIO
N
PRELI
M
IN
ARY
Project Number
Original Issue
Sheet Number
Sheet Name
Project Status
Project Designer
Project Manager
Project Architect
Landscape Architect
Civil Engineer
Structural Engineer
Mechanical Engineer
Electrical Engineer
Interior Designer
Equipment Planner
Wayfinding
Sheet Reviewer
A
B
C
D
12345
A
B
C
D
Plumbing Engineer
8' 16' 32'
09/25/2020 60% Review Submittal
11/06/2020 100% Review Submittal
/6
/2
:3 4:
A
M C
:\r vt
\2
0\
-A
-B N
L- E
IC
_C
E N
TR
A
Lv
_T yl er .D ye
5.
rv t
G-101
LIFE SAFETY PLAN -
B1002
Brookhaven National Laboratory Electron Ion Collider
Concept Design 100% Review Submittal
Upton, New York
HDR Architecture
10235960
09/16/20
HDR Arlington 3001 Washington Blvd, Suite 200 Arlington, VA 22201
Author
Gabriela Kleiman
Tyler Dye
Kevin LeMans
Joseph Dennis
Joseph Krzyzewski
Phil Beadle
Kelly Hartshorn
1/16" = 1'-0" A5
FIRST FLOOR LIFE SAFETY PLAN - B1002
1/16" = 1'-0" C5
SECOND FLOOR LIFE SAFETY PLAN - B1002
A-04A-04
B-04B-04
C-04C-04
D-04D-04
E-04E-04
F-04F-04
2-04
2-04
1-04
1-04
P U
L S
E D
S E
P T
U M
P
U L
S E
D S
E P
T U
M
D C
S E
P T
U M
SPRINKLER
STATION
P U
M P
S
P U
M P
S
M C
C P
A D
.I S
Y S
T E
M
F
IL
T E
R S
P A
P E
X P
A N
S
IO
N
A
N K
E X
H -1
E X
H -2
SEPTUM
ROOM
1004-A
DI
WATER
SYSTEM
1004-B
ELECTRICAL
EQUIPMENT
1004-C
N E
P A
N E
L
E L
P
E L
P
E L
P
MCC T T
UPS
BYPASS
SWITCH
W A
T E
R E
X C
H A
N G
E W
A T
E R
E X
C H
A N
G E
C
O M
M U
N
IC
A T
IO
N
R A
C K
S
"X
TRAVEL DISTANCE
82'-0"
Room Legend
B
C O
M M
O N
P A
T H
8'
-6
TRAVEL DISTANCE
58'-6"
LIFE SAFETY LEGEND
TRAVEL DISTANCE
999'-11"
COMMON PATH
999'-11"999'-11"
TRAVEL DISTANCE: LONGEST ROUTE TO AN EXIT (MAXIMUM PER
SPACE/AREA SHOWN) (IBC 1017.2)
COMMON PATH: DISTANCE TRAVELED BEFORE AN EXIT PATH IS CHOSEN
(MAXIMUM PER SPACE/ AREA SHOWN) (IBC 1006.2)
EXIT
1/
2" 1"
2"
NOT F
OR C
ONSTRUCTIO
N
PRELI
M
IN
ARY
Project Number
Original Issue
Sheet Number
Sheet Name
Project Status
Project Designer
Project Manager
Project Architect
Landscape Architect
Civil Engineer
Structural Engineer
Mechanical Engineer
Electrical Engineer
Interior Designer
Equipment Planner
Wayfinding
Sheet Reviewer
A
B
C
D
12345
A
B
C
D
Plumbing Engineer
8' 16' 32'
09/25/2020 60% Review Submittal
11/06/2020 100% Review Submittal
/6
/2
:3 4:
A
M C
:\r vt
\2
0\
-A
-B N
L- E
IC
_C
E N
TR
A
Lv
_T yl er .D ye
5.
rv t
G-102
LIFE SAFETY PLAN -
B1004
Brookhaven National Laboratory Electron Ion Collider
Concept Design 100% Review Submittal
Upton, New York
HDR Architecture
10235960
09/16/20
HDR Arlington 3001 Washington Blvd, Suite 200 Arlington, VA 22201
Author
Gabriela Kleiman
Tyler Dye
Kevin LeMans
Joseph Dennis
Joseph Krzyzewski
Phil Beadle
Kelly Hartshorn
1/16" = 1'-0" A5
FIRST FLOOR LIFE SAFETY PLAN - B1004
D-05
D-05
A-05
A-05
1-05 1-05
2-05 2-05
B-05
B-05
3-05 3-05
C-05
C-05
S P
R
IN
K L
E R
S T
A T
IO
N
F A
P L.
POWER DISTRIBUTION
TTN
E
P A
N E
L
B Y
P A
S S
S W
IT
C
H U
P S
C O
M M
O N
P A
7'
-6
TRAVEL DISTANCE
125'-0"
T R
A V
E L
D
IS
T A
N
0'
RCS
POWER
SUPPLIES
ALC-M-B
CONTROLS
ELECTRONICS
ALC-M-C
ELECTRICAL
EQUIPMENT
ALC-M-D
VESTIBULE
ALC-M-A
Room Legend
B
SWITCHGEAR
ALC-M-E
FUTURE EXAPNSION
A
B
C D G I
E
F
H
LIFE SAFETY LEGEND
TRAVEL DISTANCE
999'-11"
COMMON PATH
999'-11"999'-11"
TRAVEL DISTANCE: LONGEST ROUTE TO AN EXIT (MAXIMUM PER
SPACE/AREA SHOWN) (IBC 1017.2)
COMMON PATH: DISTANCE TRAVELED BEFORE AN EXIT PATH IS CHOSEN
(MAXIMUM PER SPACE/ AREA SHOWN) (IBC 1006.2)
EXIT
1/
2" 1"
2"
NOT F
OR C
ONSTRUCTIO
N
PRELI
M
IN
ARY
Project Number
Original Issue
Sheet Number
Sheet Name
Project Status
Project Designer
Project Manager
Project Architect
Landscape Architect
Civil Engineer
Structural Engineer
Mechanical Engineer
Electrical Engineer
Interior Designer
Equipment Planner
Wayfinding
Sheet Reviewer
A
B
C
D
12345
A
B
C
D
Plumbing Engineer
8' 16' 32'
09/25/2020 60% Review Submittal
11/06/2020 100% Review Submittal
/6
/2
:3 4:
A
M C
:\r vt
\2
0\
-A
-B N
L- E
IC
_C
E N
TR
A
Lv
_T yl er .D ye
5.
rv t
G-103
LIFE SAFETY PLAN -
ALC-05
Brookhaven National Laboratory Electron Ion Collider
Concept Design 100% Review Submittal
Upton, New York
HDR Architecture
10235960
09/16/20
HDR Arlington 3001 Washington Blvd, Suite 200 Arlington, VA 22201
Author
Gabriela Kleiman
Tyler Dye
Kevin LeMans
Joseph Dennis
Joseph Krzyzewski
Phil Beadle
Kelly Hartshorn
1/16" = 1'-0" A5
FIRST FLOOR LIFE SAFETY PLAN - ALC-05
1-C02 1-C02
2-C02 2-C02
3-C03 3-C03
4-C04 4-C04
A-C02
A-C02
B-C02
B-C02
C-C03
C-C03
EQUIPMENT
MAINTENANCE
AREA
1002C-B
CRYOGENIC
EQUIPMENT
1002C-A
CRYO
EQUIPMENT
CONTROLS
1002C-C
HELIUM COMPRESSOR 1-16 BAR
P U
M P
SHELIUM VACUUM COMPRESSOR
HELIUM COMPRESSOR 1-16 BAR
HELIUM VACUUM COMPRESSOR
COLD
BOX
1002C-D
C O
M M
O N
P A
5'
-6
TRAVEL DISTANCE
77'-6"
LIFE SAFETY LEGEND
TRAVEL DISTANCE
999'-11"
COMMON PATH
999'-11"999'-11"
TRAVEL DISTANCE: LONGEST ROUTE TO AN EXIT (MAXIMUM PER
SPACE/AREA SHOWN) (IBC 1017.2)
COMMON PATH: DISTANCE TRAVELED BEFORE AN EXIT PATH IS CHOSEN
(MAXIMUM PER SPACE/ AREA SHOWN) (IBC 1006.2)
EXIT
1-C02 1-C02
2-C02 2-C02
3-C03 3-C03
4-C04 4-C04
A-C02
A-C02
B-C02
B-C02
C-C03
C-C03
SWITCHGEAR
1002C-E
OPEN TO BELOW
C O
M M
O N
P A
-0
Room Legend
B
1/
2" 1"
2"
NOT F
OR C
ONSTRUCTIO
N
PRELI
M
IN
ARY
Project Number
Original Issue
Sheet Number
Sheet Name
Project Status
Project Designer
Project Manager
Project Architect
Landscape Architect
Civil Engineer
Structural Engineer
Mechanical Engineer
Electrical Engineer
Interior Designer
Equipment Planner
Wayfinding
Sheet Reviewer
A
B
C
D
12345
A
B
C
D
Plumbing Engineer
8' 16' 32'
09/25/2020 60% Review Submittal
11/06/2020 100% Review Submittal
/6
/2
:3 4:
A
M C
:\r vt
\2
0\
-A
-B N
L- E
IC
_C
E N
TR
A
Lv
_T yl er .D ye
5.
rv t
G-104
LIFE SAFETY PLAN -
CRYO 1002/06
Brookhaven National Laboratory Electron Ion Collider
Concept Design 100% Review Submittal
Upton, New York
HDR Architecture
10235960
09/16/20
HDR Arlington 3001 Washington Blvd, Suite 200 Arlington, VA 22201
Author
Gabriela Kleiman
Tyler Dye
Kevin LeMans
Joseph Dennis
Joseph Krzyzewski
Phil Beadle
Kelly Hartshorn
1/16" = 1'-0" A5
FIRST FLOOR LIFE SAFETY PLAN - CRYO 1002/06
MARK DATE DESCRIPTION
1/16" = 1'-0" B5
SECOND FLOOR LIFE SAFETY PLAN - CRYO 1002/06
1-07
1-07
4-07
4-07
B-07 B-07
C-07 C-07
D-07 D-07
E-07 E-07
2-07
2-07
3-07
3-07
A-07 A-07
Room Legend
B
UPS
BYPASS
SWITCH
P O
W E
R D
IS
T
R
IB
U T
IO
N
F A
P L
S P
R
IN
K
LE
R
S
A T
IO
N
S P
R
IN
K
LE
R
S
A T
IO
N
1 1 1 1
FUTURE EXAPNSION
RCS
POWER
SUPPLIES
ALC-L-B
VESTIBULE
ALC-L-A
SWITCHGEAR
ALC-L-E
CONTROLS
ELECTRONICS
ALC-L-C
C O
M M
O N
P A
8'
-0
TRAVEL DISTANCE
104'-0"
TRAVEL DISTANCE
115'-0"
ELECTRICAL
EQUIPMENT
ALC-L-D
A B
C D
E F G
H I
J
K K L L
M
LIFE SAFETY LEGEND
TRAVEL DISTANCE
999'-11"
COMMON PATH
999'-11"999'-11"
TRAVEL DISTANCE: LONGEST ROUTE TO AN EXIT (MAXIMUM PER
SPACE/AREA SHOWN) (IBC 1017.2)
COMMON PATH: DISTANCE TRAVELED BEFORE AN EXIT PATH IS CHOSEN
(MAXIMUM PER SPACE/ AREA SHOWN) (IBC 1006.2)
EXIT
1/
2" 1"
2"
NOT F
OR C
ONSTRUCTIO
N
PRELI
M
IN
ARY
Project Number
Original Issue
Sheet Number
Sheet Name
Project Status
Project Designer
Project Manager
Project Architect
Landscape Architect
Civil Engineer
Structural Engineer
Mechanical Engineer
Electrical Engineer
Interior Designer
Equipment Planner
Wayfinding
Sheet Reviewer
A
B
C
D
12345
A
B
C
D
Plumbing Engineer
8' 16' 32'
09/25/2020 60% Review Submittal
11/06/2020 100% Review Submittal
/6
/2
:3 4:
A
M C
:\r vt
\2
0\
-A
-B N
L- E
IC
_C
E N
TR
A
Lv
_T yl er .D ye
5.
rv t
G-105
LIFE SAFETY PLAN -
ALC-07
Brookhaven National Laboratory Electron Ion Collider
Concept Design 100% Review Submittal
Upton, New York
HDR Architecture
10235960
09/16/20
HDR Arlington 3001 Washington Blvd, Suite 200 Arlington, VA 22201
Author
Gabriela Kleiman
Tyler Dye
Kevin LeMans
Joseph Dennis
Joseph Krzyzewski
Phil Beadle
Kelly Hartshorn
1/16" = 1'-0" A5
FIRST FLOOR LIFE SAFETY PLAN - ALC-07
UP UP
A-10
A-10
B-10
B-10
C-10
C-10
D-10
D-10
E-10
E-10
F-10
F-10
H-10
H-10
G-10
G-10
J-10
J-10
K-10
K-10
L-10
L-10
M-10
M-10
1-10 1-10
3-10 3-10
4-10 4-10
2-10 2-10
POWER
SUPPLIES
1010-A
MISC.
EQUIPMENT
1010-C
OFFICE
1010-D
MISC.
EQUIPMENT
1010-G
DI
WATER
SYSTEM
1010-B
RF POWER AMPLIFIERS
LABYRINTH FOR ACCESS TO TUNNEL - ALTERNATE
RF POWER AMPLIFIERS RF POWER AMPLIFIERS RF POWER AMPLIFIERS RF POWER AMPLIFIERS
1-10.1 1-10.1
3-10.1 3-10.1
2-10.1 2-10.1
A10.1
A10.1
D10.1
D10.1
B10.1
B10.1
C10.1
C10.1
STAIR
1010-I
STAIR
1010-H
Room Legend
B
COMMON PATH
38'-0"
T R
A V
E L
D
IS
T A
N
-0
TRAVEL DISTANCE
52'-0"
C O
M M
O N
P A
-0
TRAVEL DISTANCE
120'-6"
LIFE SAFETY LEGEND
TRAVEL DISTANCE
999'-11"
COMMON PATH
999'-11"999'-11"
TRAVEL DISTANCE: LONGEST ROUTE TO AN EXIT (MAXIMUM PER
SPACE/AREA SHOWN) (IBC 1017.2)
COMMON PATH: DISTANCE TRAVELED BEFORE AN EXIT PATH IS CHOSEN
(MAXIMUM PER SPACE/ AREA SHOWN) (IBC 1006.2)
EXIT
1/
2" 1"
2"
NOT F
OR C
ONSTRUCTIO
N
PRELI
M
IN
ARY
Project Number
Original Issue
Sheet Number
Sheet Name
Project Status
Project Designer
Project Manager
Project Architect
Landscape Architect
Civil Engineer
Structural Engineer
Mechanical Engineer
Electrical Engineer
Interior Designer
Equipment Planner
Wayfinding
Sheet Reviewer
A
B
C
D
12345
A
B
C
D
Plumbing Engineer
8' 16' 32'
09/25/2020 60% Review Submittal
11/06/2020 100% Review Submittal
/6
/2
:3 4:
A
M C
:\r vt
\2
0\
-A
-B N
L- E
IC
_C
E N
TR
A
Lv
_T yl er .D ye
5.
rv t
G-106
LIFE SAFETY PLAN -
B1010 - FIRST FLOOR
Brookhaven National Laboratory Electron Ion Collider
Concept Design 100% Review Submittal
Upton, New York
HDR Architecture
10235960
09/16/20
HDR Arlington 3001 Washington Blvd, Suite 200 Arlington, VA 22201
Author
Gabriela Kleiman
Tyler Dye
Kevin LeMans
Joseph Dennis
Joseph Krzyzewski
Phil Beadle
Kelly Hartshorn
1/16" = 1'-0" A5
FIRST FLOOR LIFE SAFETY PLAN - B1010
UP UP
A-10
A-10
B-10
B-10
C-10
C-10
D-10
D-10
E-10
E-10
F-10
F-10
H-10
H-10
G-10
G-10
J-10
J-10
K-10
K-10
L-10
L-10
M-10
M-10
1-10 1-10
3-10 3-10
4-10 4-10
2-10 2-10
SECOND
FLOOR
CIRCULATORS
WAVEGUIDES
1010-F
WAVEGUIDES, CIRCULATORS,
AND DUMMY LOADS
WAVEGUIDES, CIRCULATORS,
AND DUMMY LOADS
WAVEGUIDES, CIRCULATORS,
AND DUMMY LOADS
WAVEGUIDES, CIRCULATORS,
AND DUMMY LOADS
WAVEGUIDES, CIRCULATORS,
AND DUMMY LOADS
1-10.1 1-10.1
3-10.1 3-10.1
2-10.1 2-10.1
A10.1
A10.1
D10.1
D10.1
B10.1
B10.1
C10.1
C10.1
STAIR
1010-J
STAIR
1010-K
ROOF
C O
M M
O N
P A
-0
TRAVEL DISTANCE
127'-0"
Room Legend
B
ROOF - ALTERNATE
LIFE SAFETY LEGEND
TRAVEL DISTANCE
999'-11"
COMMON PATH
999'-11"999'-11"
TRAVEL DISTANCE: LONGEST ROUTE TO AN EXIT (MAXIMUM PER
SPACE/AREA SHOWN) (IBC 1017.2)
COMMON PATH: DISTANCE TRAVELED BEFORE AN EXIT PATH IS CHOSEN
(MAXIMUM PER SPACE/ AREA SHOWN) (IBC 1006.2)
EXIT
1/
2" 1"
2"
NOT F
OR C
ONSTRUCTIO
N
PRELI
M
IN
ARY
Project Number
Original Issue
Sheet Number
Sheet Name
Project Status
Project Designer
Project Manager
Project Architect
Landscape Architect
Civil Engineer
Structural Engineer
Mechanical Engineer
Electrical Engineer
Interior Designer
Equipment Planner
Wayfinding
Sheet Reviewer
A
B
C
D
12345
A
B
C
D
Plumbing Engineer
8' 16' 32'
09/25/2020 60% Review Submittal
11/06/2020 100% Review Submittal
/6
/2
:3 4:
A
M C
:\r vt
\2
0\
-A
-B N
L- E
IC
_C
E N
TR
A
Lv
_T yl er .D ye
5.
rv t
G-107
LIFE SAFETY PLAN -
B1010 - SECOND
FLOOR
Brookhaven National Laboratory Electron Ion Collider
Concept Design 100% Review Submittal
Upton, New York
HDR Architecture
10235960
09/23/20
HDR Arlington 3001 Washington Blvd, Suite 200 Arlington, VA 22201
Author
Gabriela Kleiman
Tyler Dye
Kevin LeMans
Joseph Dennis
Joseph Krzyzewski
Phil Beadle
Kelly Hartshorn
1/16" = 1'-0" A5
SECOND FLOOR LIFE SAFETY PLAN - B1010
A-C10
A-C10
C-C10
C-C10
1-C101-C10
2-C102-C10
3-C103-C10
4-C104-C10
B-C10
B-C10
5-C105-C10
CRYO
EQUIPMENT
CONTROLS
1010C-C
EQUIPMENT
MAINTENANCE
AREA
1010C-B
CRYOGENIC
EQUIPMENT
1010C-A
HELIUM VACUUM COMPRESSOR
HELIUM VACUUM COMPRESSOR
HELIUM COMPRESSOR 1-16 BAR
HELIUM COMPRESSOR 1-16 BAR
P U
M P
S
HELIUM VACUUM COMPRESSOR
COLD
BOX
1010C-D
COMMON PATH
35'-6"
TRAVEL DISTANCE
77''-0"
TRAVEL DISTANCE
70''-0"
LIFE SAFETY LEGEND
TRAVEL DISTANCE
999'-11"
COMMON PATH
999'-11"999'-11"
TRAVEL DISTANCE: LONGEST ROUTE TO AN EXIT (MAXIMUM PER
SPACE/AREA SHOWN) (IBC 1017.2)
COMMON PATH: DISTANCE TRAVELED BEFORE AN EXIT PATH IS CHOSEN
(MAXIMUM PER SPACE/ AREA SHOWN) (IBC 1006.2)
EXIT
A-C10
A-C10
C-C10
C-C10
1-C101-C10
2-C102-C10
3-C103-C10
4-C104-C10
B-C10
B-C10
5-C105-C10
SWITCHGEAR
1010C-E
OPEN TO BELOW
C O
M M
O N
P A
-6
Room Legend
B
1/
2" 1"
2"
NOT F
OR C
ONSTRUCTIO
N
PRELI
M
IN
ARY
Project Number
Original Issue
Sheet Number
Sheet Name
Project Status
Project Designer
Project Manager
Project Architect
Landscape Architect
Civil Engineer
Structural Engineer
Mechanical Engineer
Electrical Engineer
Interior Designer
Equipment Planner
Wayfinding
Sheet Reviewer
A
B
C
D
12345
A
B
C
D
Plumbing Engineer
8' 16' 32'
09/25/2020 60% Review Submittal
11/06/2020 100% Review Submittal
/6
/2
:3 4:
A
M C
:\r vt
\2
0\
-A
-B N
L- E
IC
_C
E N
TR
A
Lv
_T yl er .D ye
5.
rv t
G-108
LIFE SAFETY PLAN -
CRYO 1010
Brookhaven National Laboratory Electron Ion Collider
Concept Design 100% Review Submittal
Upton, New York
HDR Architecture
10235960
09/16/20
HDR Arlington 3001 Washington Blvd, Suite 200 Arlington, VA 22201
Author
Gabriela Kleiman
Tyler Dye
Kevin LeMans
Joseph Dennis
Joseph Krzyzewski
Phil Beadle
Kelly Hartshorn
1/16" = 1'-0" A5
FIRST FLOOR LIFE SAFETY PLAN - CRYO 1010
MARK DATE DESCRIPTION
1/16" = 1'-0" B5
SECOND FLOOR LIFE SAFETY PLAN - CRYO 1010
A-12
A-12
C-12
C-12
D-12
D-12
E-12
E-12
3-12 3-12
5-12 5-12
4-12 4-12
2-12 2-12
1-12 1-12
B-12
B-12
DC/SLOW PULSE SEPTUM 3 ESR INJECTION
PULSED SEPTUM 1 ESR INJECTION
ESR INJECTION BUMP 3
BUMP OR KICKER 3 ESR INJECTION CORRECTION
RESERVE
DC/SLOW PULSE SEPTUM 2 ESR INJECTION
DC/SLOW PULSE SEPTUM 5 ESR INJECTION
ESR INJECTION BUMP 2
BUMP OR KICKER 2 ESR INJECTION CORRECTION
RESERVE
DC/SLOW PULSE SEPTUM 1 ESR INJECTION
DC/SLOW PULSE SEPTUM 4 ESR INJECTION
ESR INJECTION BUMP 1
BUMP OR KICKER 1 ESR INJECTION CORRECTION
RESERVE
NA
PG6
PG5
P U
M P
S
X H
-1
P U
M P
S
SPRINKLER
STATION
FIRE ALARM PL.
DI
WATER
SYSTEM
1012-A
POWER
SUPPLIES
1012-C
POWER
SUPPLIES
1012-B
KICKER 2 RCS EXTRACTION
KICKER 5 RCS EXTRACTION
KICKER 1 RCS EXTRACTION
KICKER 4 RCS EXTRACTION
PULSED SEPTUM 1 RCS EXTRACTION
DC/SLOW PULSED SEPTUM 3 RCS EXTRACTION
ESR INJECTION BUMP 1
DC/SLOW PULSE SEPTUM 1 ESR INJECTION
DC/SLOW PULSE SEPTUM 4 ESR INJECTION
ESR INJECTION BUMP 2 ESR INJECTION BUMP 3
DC/SLOW PULSE SEPTUM 5 ESR INJECTION
DC/SLOW PULSE SEPTUM 2 ESR INJECTION
RESERVE
KICKER 3 RCS EXTRACTION
PG3
PG4
PG3
M C
C T
T
NE
PANEL
ELP1
ELP2
ELP3
ELECTRICAL
EQUIPMENT
1012-D
VESTIBULE
1012-F
UPS
BYPASS
SWITCH
W A
T E
R E
X C
H A
N G
E W
A T
E R
E X
C H
A N
G E
COMMUNICATION RACKS
C O
M M
O N
P A
-0
T R
A V
E L
D
IS
T A
N
'-6
TRAVEL DISTANCE
110'-0"
WATER
EXCHANGE
1012-E
Room Legend
B
LIFE SAFETY LEGEND
TRAVEL DISTANCE
999'-11"
COMMON PATH
999'-11"999'-11"
TRAVEL DISTANCE: LONGEST ROUTE TO AN EXIT (MAXIMUM PER
SPACE/AREA SHOWN) (IBC 1017.2)
COMMON PATH: DISTANCE TRAVELED BEFORE AN EXIT PATH IS CHOSEN
(MAXIMUM PER SPACE/ AREA SHOWN) (IBC 1006.2)
EXIT
1/
2" 1"
2"
NOT F
OR C
ONSTRUCTIO
N
PRELI
M
IN
ARY
Project Number
Original Issue
Sheet Number
Sheet Name
Project Status
Project Designer
Project Manager
Project Architect
Landscape Architect
Civil Engineer
Structural Engineer
Mechanical Engineer
Electrical Engineer
Interior Designer
Equipment Planner
Wayfinding
Sheet Reviewer
A
B
C
D
12345
A
B
C
D
Plumbing Engineer
8' 16' 32'
09/25/2020 60% Review Submittal
11/06/2020 100% Review Submittal
/6
/2
:3 4:
A
M C
:\r vt
\2
0\
-A
-B N
L- E
IC
_C
E N
TR
A
Lv
_T yl er .D ye
5.
rv t
G-109
LIFE SAFETY PLAN -
B1012
Brookhaven National Laboratory Electron Ion Collider
Concept Design 100% Review Submittal
Upton, New York
HDR Architecture
10235960
09/16/20
HDR Arlington 3001 Washington Blvd, Suite 200 Arlington, VA 22201
Author
Gabriela Kleiman
Tyler Dye
Kevin LeMans
Joseph Dennis
Joseph Krzyzewski
Phil Beadle
Kelly Hartshorn
1/16" = 1'-0" A5
FIRST FLOOR LIFE SAFETY PLAN - B1012
TDYE
Polygon
AISC
AISI
ACI
ASCE
ASTM
ASWG
AWG
ASSN
APPROX
ARCH
AVG
B/
BLDG
BOT
BRG
BSMT
BM
C
CH
CHAN
CIR
C, C
CLG
CEM
CMU
COL
CONC
CONN
CONST
CONST JT
CONT
CONFIG
CONTR
CORP
CR
CRS
CS
CSG
CTR
DBL
DEG
DEP
DIA, Ø
DIM
DET
DN
DO
EA
EF
ELEC
EQ
EQUIP
EW
EXIST
EXP
EXT
FAB
FDN
F TO F
FF
FIN
FIN DIM
FIN GR
FL
FLG
FL PL
FOB
GRWT
GRD
EOD
EOS
ADD'L
CLR
EMB
ADJ
ALT
c/c
CJ
DIAG
ELEV, EL
FFE
GALV
GRTG
BOP
BS
= AMERICAN SOCIETY OF CIVIL ENGINEERS
= AVERAGE
= ARCHITECT OR ARCHITECTURAL
= APPROXIMATE OR APPROXIMATELY
= ASSOCIATION
= AMERICAN WIRE GAGE
= AMERICAN STEEL AND WIRE GAGE
= AMERICAN SOCIETY FOR TESTING AND MATERIALS
= ALTERNATE
= ADJUSTABLE, ADJUST
= ADDITIONAL
= AMERICAN CONCRETE INSTITUTE
= AMERICAN IRON AND STEEL INSTITUTE
= AMERICAN INSTITUTE OF STEEL CONSTRUCTION
= BOTTOM OF
= BUILDING
= BOTTOM
= BEARING
= BASEMENT
= BEAM
= BOTTOM OF PIPE
= BOTH SIDES
= CONCRETE
= CONTROL JOINT
= CENTER OR CENTERED
= CASTING
= CARBON STEEL
= COLD ROLLED STEEL
= COLD ROLLED
= CORPORATION
= CONTRACTOR
= CONFIGURATION
= CONTINUOUS
= CONSTRUCTION JOINT
= CONSTRUCTION
= CONNECT OR CONNECTION
= CENTER TO CENTER
= CLEAR
= COLUMN
= CONCRETE MASONRY UNIT
= CEMENT
= CEILING
= CENTER LINE
= CIRCULAR
= CHANNEL
= CHECKED
= CHANNEL
= DOUBLE
= DEGREE
= DEPTH OR DEPRESSION
= DIAMETER
= DIAGRAM, DIAGONAL
= DIMENSION
= DETAIL
= DOWN
= DITTO - INDICATES SAME SIZE AS ADJACENT MEMBER
= EQUAL
= EDGE OF SLAB
= EDGE OF DECK
= EXTENT OR EXTERIOR
= EXPANSION
= EXISTING
= EACH WAY
= EQUIPMENT
= EACH FACE
= ELEVATION OR ELEVATOR
= ELECTRIC OR ELECTRICAL
= EACH
= EMBEDDED OR EMBEDMENT
= FINISHED FLOOR ELEVATION
= FACE OF BUILDING
= FLOOR PLAN
= FLANGE
= FLOOR
= FINISH GRADE
= FINISH DIMENSION
= FINISH
= FINISHED FLOOR
= FACE TO FACE
= FOUNDATION
= FABRICATE
= GRATING
= GROSS WEIGHT
= GROUND
= GALVANIZE OR GALVANIZED
HP
HORIZ
HSS
HGR
HDD = HEADED
= HIGH POINT
= HORIZONTAL
= HOLLOW STEEL SECTION
= HANGER
L
DWG = DRAWING
@ = AT
& = AND
= FIGUREFIG
= EXPANSION JOINTEXP JT
WT = WEIGHT
= WELDED WIRE FABRICWWF
= STRUCTURE OR STRUCTURAL
= TOP OF
= TYPICAL
= THICKNESS OR THICK
= TOP OF STEEL
= TOP OF CONCRETE
= UNLESS OTHERWISE NOTED
= UNLESS NOTED OTHERWISE
= UNDERGROUND
= VERIFY IN FIELD
= VERTICAL
= VERTICAL EACH FACE
= WORKING POINT
= WITHOUT
= WELDING
= TOP OF WALL
UON
WELD
W/O
WP
W/ = WITH
VEF
VERT
VIF
TOS
UNO
U/G
TYP
TOW
T/
THK
TOC
STRUC
PERP = PERPENDICULAR
= PRESSURE
= POINT
= PLUMBING
= PLASTER
= PLATE
= REQUIRED
= REVISION OR REVISED
= REINFORCING BAR
= REFERENCE
= SPACING
= SIMILAR
= SPECIFICATION
= STANDARD
= STAINLESS STEEL
= STEEL PLATE
= STEEL
= SCHEDULE
= SECTION
= SHEET
= SECOND
= RADIUS
ST STL
STL PL
STL
SPCG
SPEC
STD
SIM
SHT
SECT
SEC
SCH
REQ'D
REV
REBAR
REF
RAD
PLAS
PRESS
PT
PLBG
PL
= MECHANICAL
= MEZZANINE
= MANUFACTURER
= MINIMUM
= MISCELLANEOUS
= NORMAL WEIGHT
= NOT APPLICABLE
= NOT IN CONTRACT
= NOMINAL
= NUMBER
= NOT TO SCALE
= OUTSIDE DIAMETER
= OPENING
= OPPOSITE
= ON CENTER
= OPPOSITE HAND
= PRECAST CONCRETE
= PIECE OR PRECAST
NTS
OPP
PC
PCC
OPP HD
oc
OPNG
OD
NLWT
No./#
NOM
NIC
N/A
MIN
MISC
MECH
MEZZ
MFR
= ISOMETRIC
= ISOLATION JOINT
= INSIDE DIAMETER OR DIMENSION
= INCORPORATED
= INSULATION OR INSULATING
= INSTALL OR INSTALLATION
= INTERIOR
= INVERT
= JOINT
= JOIST
= LOW POINT
= LIGHT WEIGHT
= LENGTH
= LONG LEG BACK TO BACK
= LONG LEG HORIZONTAL
= LONG LEG VERTICAL
= LOCATION
= MATERIAL
= MAXIMUM
= LONG
MAX
MATL
LP
LTWT
LLH
LLV
LOC
LG
LGTH
LLBB
INT
JT
JST
INV
ISO
INC
INSUL
INST
ID
IJ
FTG = FOOTING
= GRADE BEAMGBM
= POWER DRIVEN FASTENERPDF
= REBAR HOOK DEVELOPMENT LENGTHLdh
= REBAR DEVELOPMENT LENGTHLd
Lc = LENGTH OF SPAN c
Lb = LENGTH OF SPAN b
La = LENGTH OF SPAN a
MEP = MECHANICAL, ELECTRICAL, PLUMBING
= HEIGHTHT
= WIDE FLANGEWF
LFV
LFH = LONG FACE HORIZONTAL
= LONG FACE VERTICAL
= STAINLESS STEELSS
ABBREVIATIONS
APPLICABLE CODES AND STANDARDS
1.) BUILDING CODE 2020 OF NEW YORK STATE.
2.) THE INTERNATIONAL BUILDING CODE, IBC 2018.
3.) BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE (ACI 318-14).
4.) AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC), MANUAL OF STEEL CONSTRUCTION, 360-16.
5.) AMERICAN WELDING SOCIETY (AWS) D1.1, D1.3, D1.4, D1.8.
6.) MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES (ASCE 7-16).
7.) STEEL DECK INSTITUTE SPECIFICATIONS AND LOAD TABLES.
8.) ASTM MATERIAL STANDARDS AS NOTED.
9.) AISI SPECIFICATIONS FOR DESIGN OF COLD FORMED STEEL STRUCTURAL MEMBERS (AISI S100).
10.) STEEL JOIST INSTITUTE, STANDARD SPECIFICATIONS, LOAD TABLES, AND WEIGHT TABLES FOR
STEEL JOISTS AND JOIST GIRDERS.
11.) BUILDING CODE REQUIREMENTS AND SPECIFICATIONS FOR MASONRY STRUCTURES (TMS 402)
DESIGN LOADS
1.) DEAD LOAD – ACTUAL WEIGHT OF MATERIALS USED ADDING THE FOLLOWING:
ROOF
FRAMING AND DECK 10 PSF
ROOFING/INSULATION 5 PSF
CEILING 5 PSF
TYPICAL MEP SYSTEMS 10 PSF
CABLE TRAY/RACK SYSTEMS 40 PSF
FLOOR
FRAMING 12 PSF
2 1/2" N.W. SLAB ON 3" DECK 50 PSF
LEVELING CONCRETE (1" TO 1 1/2" AVG.) 10 PSF
CEILING 5 PSF
TYPICAL MEP SYSTEMS 10 PSF
MEP SYSTEMS ABOVE MECH. ROOM 20 PSF
CABLE TRAY/RACK SYSTEMS 40 PSF
STAIR
FRAMING 10 PSF
EXTERIOR WALLS
METAL PANEL/CURTAIN WALL 20 PSF
MASONRY 75 PSF OF WALL SURFACE
2.) LIVE LOAD
AREA OF BUILDING DESIGN LIVE LOAD
ROOF 20 PSF (MINIMUM)
GENERAL OFFICE AREAS, STAIR, CORRIDORS 100 PSF
CORRIDORS ABOVE FIRST FLOOR 80 PSF
LABORATORIES 125 PSF
MECHANICAL ROOMS 150 PSF
MEZZANINE/CATWALK 40 PSF
LIGHT STORAGE 125 PSF
HIGH DENSITY STORAGE 250 PSF
RAILINGS 50 PLF / 200 LBS. CONCENTRATED
CMU PARTITION 60 PSF OF WALL SURFACE
*15 PSF PARTITION ALLOWANCE IS INCLUDED
3.) SNOW LOAD
GROUND SNOW LOAD Pg = 20 PSF FLAT ROOF SNOW LOAD Pf = 14 PSF SNOW EXPOSURE FACTOR Ce = 1.0
SNOW LOAD IMPORTANCE FACTOR I = 1
THERMAL FACTOR Ct = 1.0
4.) WIND LOAD
RISK CATEGORY = I I
BASIC WIND VELOCITY Vult = 127 MPH
EXPOSURE CATEGORY = C
5.) SEISMIC LOAD
IN ACCORDANCE WITH THE INTERNATIONAL BUILDING CODE.
SEISMIC IMPORTANCE FACTOR, Ie = 1.00
MAPPED SPECTRAL RESPONSE
ACCELERATIONS PARAMETERS, Ss = 0.178 g AND S1 = 0.049 g
SITE CLASS = D
SPECTRAL RESPONSE COEFFICIENTS, Sds = 0.190 g AND Sd1 = 0.079 g
SEISMIC DESIGN CATEGORY: B
FOUNDATION DESIGN
1.) ASSUMED ALLOWABLE SOIL BEARING CAPACITY = 4,000 PSF, UNLESS NOTED OTHERWISE ON PLAN, TO BE CONFIRMED BY THE GEOTECHNICAL ENGINEER DURING CONSTRUCTION.
2.) FROST DEPTH = - 3' - 6"
MATERIALS OF CONSTRUCTION
1.) NORMAL WEIGHT CONCRETE 28 DAY COMPRESSIVE STRENGTH
GENERAL STRUCTURAL CONCRETE F’c = 4,000 PSI
2.) REINFORCING STEEL – ASTM A615 - GRADE 60 Fy = 60 KSI
3.) WELDED WIRE FABRIC – ASTM A185 Fy = 70 KSI
4.) STRUCTURAL STEEL
WIDE FLANGE AND TEE SHAPES - ASTM A992 Fy = 50 KSI ANGLES CHANNELS AND PLATE - ASTM A 36 Fy = 36 KSI HSS TUBES AND PIPES - ASTM A500 Fy = 46 KSI PIPES - ASTM A53 GRADE B Fy = 35 KSI
BOLTS - ASTM F1582
ANCHOR BOLTS - ASTM F1554 GRADE 36 Fy = 36 KSI
HIGH STRENGTH ANCHOR BOLT ASSEMBLY
ANCHOR BOLT - ASTM F1554 GRADE 105 Fy = 105 KSI
NUTS – GRADE ASTM A563 GRADE D
WELDING ELECTRODES - E70XX
METAL ROOF DECKING (GALVANIZED)
ASTM A653 G60 (Z180) ZINC COATING FY = 33 KSI, STRUCT. QUALITY
5.) NON-SHRINK GROUT AND NON-METALLIC GROUT F'c = 4,000 PSI AT 7 DAYS AT BASE PLATES AND BEARING PLATES F'c = 8,000 PSI AT 28 DAYS
CONSTRUCTION NOTES
A. GENERAL CONSTRUCTION NOTES
1.) STRUCTURAL DRAWINGS SHOULD NOT BE SCALED. PRINTED DIMENSIONS HAVE
PRECEDENCE OVER SCALED DRAWINGS AND LARGE SCALE OVER SMALL.
2.) THE CONTRACTOR SHALL VISIT THE SITE AND FAMILIARIZE HIMSELF WITH EXISTING
CONDITIONS. CHECK AND VERIFY EXISTING DIMENSIONS AND TAKE ADDITIONAL
MEASUREMENTS AS NEEDED. NOTIFY ARCHITECT OF ANY DISCREPANCY BETWEEN ACTUAL
CONDITIONS AND INDICATED CONDITIONS. MODIFICATION OF DETAILS OF CONSTRUCTION
SHALL NOT BE MADE WITHOUT WRITTEN APPROVAL OF THE ARCHITECT OR STRUCTURAL
ENGINEER.
3.) ALL DRAWINGS AND SPECIFICATIONS ARE CONSIDERED TO BE A PART OF THE CONTRACT
DOCUMENTS. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH THE CIVIL,
ARCHITECTURAL, MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS FOR LOCATION AND
SIZE OF OPENINGS, BLOCKOUTS, FLOOR DEPRESSIONS, CURBS, DIMENSIONS, ETC. NOT
INDICATED ON THE STRUCTURAL DRAWINGS. THE LOCATION AND SIZE OF MECHANICAL
AND ELECTRICAL OPENINGS IN SLABS, WALLS AND DECKS SHALL BE COORDINATED BY
THE CONTRACTOR. PROVIDE ALL ADDITIONAL FRAMING OR REINFORCING TO ACCOMMODATE
OPENINGS AS REQUIRED BY THE APPLICABLE STANDARD DETAILS SHOWN ON THE
STRUCTURAL DRAWINGS OR PROVIDED BY THE STRUCTURAL ENGINEER. NO HOLES,
NOTCHES, BLOCKOUTS, ETC. ARE ALLOWED IN STRUCTURAL MEMBERS UNLESS DETAILED
ON THE STRUCTURAL DRAWINGS OR APPROVED BY THE STRUCTURAL ENGINEER.
4.) WHERE DIMENSIONS ARE PROVIDED FOR OPENINGS, BLOCKOUTS, FLOOR DEPRESSIONS,
CURBS, ETC., BUT MAY BE AFFECTED BY THE EQUIPMENT PURCHASED, THE
CONTRACTOR SHALL VERIFY THE INFORMATION PROVIDED PRIOR TO CONSTRUCTION.
5.) PROVIDE CONCRETE EQUIPMENT PADS AND INERTIAL BASES FOR MECHANICAL AND
ELECTRICAL INSTALLATIONS. CONSTRUCT PADS AND BASES IN ACCORDANCE WITH THE
TYPICAL DETAILS. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR LIMITS AND
LOCATIONS.
6.) CONTRACTOR SHALL PROVIDE AND BE RESPONSIBLE FOR THE PROTECTION AND REPAIR
OF ADJACENT EXISTING SURFACES AND AREAS WHICH MAY BE DAMAGED BY NEW WORK.
7.) ALL COLUMNS AND FOUNDATIONS, UNLESS NOTED OTHERWISE, SHALL BE CENTERED ON
GRIDLINES IN EACH DIRECTION. BEAMS SHALL BE EQUALLY SPACED BETWEEN COLUMN
CENTERLINES UNLESS NOTED OTHERWISE.
8.) TYPICAL DETAILS SHALL APPLY IN GENERAL CONSTRUCTION UNLESS SPECIFICALLY
DETAILED. WHERE NO DETAILS ARE GIVEN, CONSTRUCTION SHALL BE AS SHOWN FOR
SIMILAR WORK.
9.) THE CONTRACTOR SHALL BE RESPONSIBLE FOR ADEQUATE DESIGN AND CONSTRUCTION
OF ALL FORMS, SHORING AND TEMPORARY BRACING. THE CONTRACTOR SHALL PROVIDE
ALL MEASURES NECESSARY TO PROTECT THE STRUCTURE AND SAFETY OF WORKMEN
DURING CONSTRUCTION.
A.) DO NOT PLACE CONSTRUCTION MATERIALS OR OTHER CONSTRUCTION LOADS ON
THE STRUCTURE SUCH THAT THE LOADS PLACED EXCEED THE CAPACITY OF
THE STRUCTURE.
B.) TAKE INTO CONSIDERATION THAT FULL STRUCTURAL CAPACITY OF MANY
STRUCTURAL MEMBERS IS NOT REALIZED UNTIL STRUCTURAL ASSEMBLY IS
COMPLETE; THAT IS, UNTIL SLABS, DECKS, DIAGONAL BRACING AND SHEAR
WALLS ARE INSTALLED.
C.) PROVIDE TEMPORARY BRACING AND GUYING TO PROVIDE STABILITY AND RESIST
ALL LOADS TO WHICH THE PARTIALLY COMPLETED STRUCTURE MAY BE
SUBJECTED INCLUDING ERECTION EQUIPMENT AND ITS OPERATION. ADEQUACY
OF TEMPORARY BRACING AND GUYING FOR THIS PURPOSE IS THE SOLE
RESPONSIBILITY OF THE CONTRACTOR.
B. EARTHWORK AND FOUNDATIONS
1.) ALL EARTHWORK AND SITE PREPARATION SHALL BE PERFORMED IN STRICT ACCORDANCE
WITH THE SPECIFICATIONS. ALL FOUNDATION EXCAVATIONS SHALL BE OBSERVED AND
APPROVED BY THE GEOTECHNICAL ENGINEER.
2.) ANY EXISTING FILLS OR UNSUITABLE SOILS AS DETERMINED BY THE GEOTECH SHALL BE
EXCAVATED AND REPLACED WITH PROPERLY COMPACTED FILL.
3.) EXTREME CARE SHALL BE EXERCISED WHEN EXCAVATING OR GRADING ADJACENT TO
EXISTING STRUCTURES OR IMPROVEMENTS SO AS NOT TO DAMAGE OR UNDERMINE
FOUNDATIONS, WALLS, SLABS, UTILITIES, ETC.
4.) DO NOT EXCAVATE BELOW THE BEARING ELEVATION OF ANY COMPLETED FOOTING NOR
ANY CLOSER TO THE FOOTING THAN A SLOPE OF TWO HORIZONTAL (MEASURED FROM
EDGE OF FOOTING TO NEAREST POINT IN EXCAVATION) TO ONE VERTICAL.
5.) HORIZONTAL CONSTRUCTION JOINTS IN COLUMN FOOTINGS, PILE CAPS, SLABS ON GRADE
AND MAT FOUNDATIONS ARE NOT PERMITTED.
6.) PROVIDE DOWELS FOR ALL WALLS, COLUMNS, AND SHEAR WALLS EMBEDDED INTO
FOOTINGS, MAT FOUNDATIONS AND GRADE BEAMS. DOWELS SHALL BE THE SAME SIZE AND
SPACING AS VERTICAL WALL REINFORCEMENT.
7.) BOTTOM OF ALL FOOTINGS SUBJECT TO FROST SHALL BE PLACED AT OR
BELOW FROST DEPTH.
C. CONCRETE AND REINFORCING
1.) LOCATION OF CONSTRUCTION JOINTS OR POUR JOINTS SHALL BE AS INDICATED ON
APPROVED SHOP DRAWINGS.
2.) ALL CONCRETE SHALL BE VIBRATED DURING PLACEMENT.
3.) PROVIDE 3/4" CHAMFER ON ALL EXPOSED CONCRETE CORNERS.
4.) NO STAKES, STEEL OR WOOD, SHALL BE PERMITTED IN ANY CONCRETE POUR. SUSPEND
FORMS FROM ABOVE GRADE.
5.) ANCHOR BOLTS, DOWELS, REINFORCING STEEL, INSERTS, ETC., SHALL BE SECURELY TIED
IN PLACE PRIOR TO POURING CONCRETE. CONCRETE BLOCKS ONLY SHALL BE USED TO
SUPPORT REINFORCING OFF GRADE.
6.) ALL REINFORCEMENT SHALL BE DETAILED, FABRICATED AND PLACED IN ACCORDANCE
WITH ACI 315.
7.) PROVIDE MINIMUM CONCRETE COVERING FOR REINFORCEMENT AS FOLLOWS:
CONDITION CLEAR COVER
CONCRETE DEPOSITED AGAINST EARTH: 3 IN.
FORMED SURFACES EXPOSED TO WEATHER OR IN CONTACT WITH EARTH:
REINFORCING BARS NO.6 OR LARGER 2 IN.
REINFORCING BARS LESS THAN NO.6. 1-1/2 IN.
BUILDING INTERIOR SURFACES:
BEAMS, GIRDERS, AND COLUMNS 1-1/2 IN.
SLABS, WALLS AND JOISTS:
NO.11 BARS OR SMALLER 3/4 IN.
NO.14 AND NO.18 BARS 1 1/2 IN.
8.) PROVIDE DOWELS OF SAME SIZE AND NUMBER FROM ADJACENT POUR, BOTH VERTICALLY
AND HORIZONTALLY, TO MATCH TYPICAL REINFORCING SHOWN. LAPS TO BE IN
ACCORDANCE WITH THE DEVELOPMENT LENGTH AND LAP SPLICE SCHEDULE. DOWELS
SHALL BE CLEANED AFTER POUR.
9.) FIELD WELDING OR BENDING OF REINFORCING IS NOT PERMITTED EXCEPT AS INDICATED
ON THE DRAWINGS OR AS APPROVED BY THE STRUCTURAL ENGINEER. USE LOW
HYDROGEN ELECTRODES GRADE E70 OR E90 AS REQUIRED.
10.) CONTINUOUS REINFORCEMENT IN WALLS AND FOOTINGS MAY BE SPLICED AS REQUIRED,
PROVIDED THAT BARS ARE OF THE LONGEST PRACTICAL LENGTH AND ALL SPLICES ARE
SHOWN ON THE REINFORCING BAR SHOP DRAWINGS. SPLICES ARE TO BE STAGGERED
WHEN POSSIBLE. PROVIDE LAP SPLICES AND DEVELOPMENT LENGTHS IN ACCORDANCE
WITH THE DEVELOPMENT LENGTH AND LAP SPLICE SCHEDULE. USE CLASS 'B' LAP
SPLICES UNLESS NOTED OTHERWISE.
11.) CORING OF SLABS, BEAMS, COLUMNS, OR SHEAR WALLS IS NOT PERMITTED. PROVIDE SLEEVES
FOR ALL PENETRATIONS PRIOR TO PLACING CONCRETE.
E. ADHESIVE ANCHORS AND DOWEL BARS
1.) REINFORCING BAR DOWELS, REINFORCING BARS, THREADED RODS, BOLTS ETC. WHICH
ARE INDICATED AS ADHESIVE ANCHORS OR ADHESIVE DOWELS IN CONCRETE OR SOLID
MASONRY SHALL BE ACCOMPLISHED USING HIT HY-150 MAX SD SYSTEM BY HILTI
FASTENING SYSTEMS OF TULSA, OK. (ICC REPORT NO. ESR 3013), OR EQUAL.
2.) DRILL, BRUSH, AND CLEAN ALL HOLES, AND INSTALL ALL ANCHORS IN COMPLETE
ACCORDANCE WITH MANUFACTURERS PUBLISHED RECOMMENDATIONS, AS WELL AS ALL
APPLICABLE BUILDING CODES OR ENGINEERING REPORTS.
3.) PROVIDE THE FOLLOWING MINIMUM ANCHOR EMBEDMENT DEPTHS UNLESS SPECIFICALLY
NOTED OTHERWISE ON THE DETAILS:
A. REINFORCING BARS
BAR SIZE EMBEDMENT DEPTH
#3 (#10) 4" (100) #4 (#13) 6" (150) #5 (#16) 7" (175) #6 (#19) 9" (225) #7 (#22) 10" (250) #8 (#25) 12" (300) #9 (#29) 13" (325) #10 (#32) 16" (400) #11 (#36) 18" (450)
B. BOLTS OR THREADED RODS
DIAMETER EMBEDMENT DEPTH
3/8"(10) 5" (125) 1/2"(13) 7" (175) 5/8"(16) 8" (200) 3/4"(19) 10" (250) 7/8"(22) 12" (300) 1" (25) 13" (330)
C. HILTI HIS INSERTS
DIAMETER EMBEDMENT DEPTH
3/8" (10) 4 1/4" (110) 1/2" (13) 5" (125) 5/8" (16) 6 5/8" (170) 3/4" (19) 8 1/4" (210)
4.) WHEN INSTALLING DRILLED-IN-ANCHORS, USE CARE AND CAUTION TO AVOID CUTTING
OR DAMAGING THE EXISTING REINFORCING BARS. WHEN INSTALLING THEM INTO
CONCRETE WITH STRESS IN TENDONS (POST-TENSIONED OR PRE-TENSIONED), LOCATE
THE TENDONS BY USING A NON-DESTRUCTIVE METHOD PRIOR TO INSTALLATION.
EXERCISE EXTREME CARE AND CAUTION AND MAINTAIN AT LEAST 1" CLEAR BETWEEN
THE TENDON AND THE ANCHOR, CUTTING A TENDON CAN CAUSE COLLAPSE.
F. HEADED STUDS
1.) HEADED STUDS AND DEFORMED BAR ANCHORS SHALL BE ELECTRIC-ARC STUD WELDED
PER MANUFACTURERS RECOMMENDATIONS AND THE AWS CODE. FILLET WELDING SHALL
NOT BE ALLOWED WITHOUT APPROVAL OF THE STRUCTURAL ENGINEER. WELDMENT SHALL
BE IN SUCH A MANNER AS TO PROVIDE COMPLETE FUSION BETWEEN THE END OF THE
STUD AND THE PLATE. THERE SHOULD BE NO POROSITY OR EVIDENCE OF LACK OF FUSION
BETWEEN THE WELDED END OF THE STUD AND THE PLATE. THE STUD WILL DECREASE IN
LENGTH DURING WELDING APPROXIMATELY 1/8” FOR 5/8” DIAMETER STUDS AND SMALLER,
3/16” FOR LARGER THEN 5/8” DIAMETER.
2.) HEADED STUDS SHALL BE TYPE B PER THE AWS CODE WITH A MINIMUM YIELD STRENGTH
OF 51 KSI (345 Mpa). NELSON GRANULAR FLUX FILLED (OR APPROVED EQUAL). STUDS
SHALL BE MANUFACTURED OF COLD DRAWN BAR STOCK CONFORMING TO ASTM A-108.
3.) UNLESS NOTED OTHERWISE, DEFORMED BAR ANCHOR LENGTH SHALL BE AS FOLLOWS:
BAR DIAMETER EMBEDMENT LENGTH
3/8"(10) 24" (600) 1/2"(13) 24" (600) 5/8"(16) 30" (750)
I. STAIR DESIGN
1.) CONTRACTOR SHALL PROVIDE COMPLETE DRAWINGS AND CALCULATIONS FOR ALL
STAIRWAYS. STAIRS, STAIR LANDINGS, STAIR MEMBERS, AND SUPPORTS NOT SHOWN
SHALL BE STRUCTURALLY DESIGNED, DETAILED AND SEALED BY A PROFESSIONAL
ENGINEER REGISTERED IN THE STATE THAT THE PROJECT IS LOCATED.
2.) ALL REQUIRED EMBEDDED ANGLES AND PLATES SHALL BE PART OF THE STAIR DESIGN
AND DETAILING.
3.) STAIRWAYS SHALL BE DESIGNED FOR DEAD LOAD, LIVE LOAD OF 100 PSF (4.8 kPa) AND
SEISMIC LOADS.
4.) STAIRS AND RELATED ITEMS SHALL COMPLY WITH THE BUILDING CODE.
5.) REFER TO THE ARCHITECTURAL DRAWINGS FOR STAIRWAY DIMENSIONS, DETAILS AND
OTHER REQUIREMENTS.
6.) STAIRS MAY BE SUPPORTED BY THE PRIMARY STRUCTURE PROVIDED STAIR FRAMING DOES
NOT IMPOSE ECCENTRIC OR TORSIONAL LOADING UPON THE PRIMARY FRAMING.
L. STEEL STUD EXTERIOR WALL FRAMING
1.) CONTRACTOR SHALL PROVIDE COMPLETE DRAWINGS AND CALCULATIONS FOR ALL EXTERIOR
STEEL STUD WALL FRAMING. ALL FRAMING MEMBERS, SPACING AND CONNECTIONS SHALL
BE DESIGNED, DETAILED AND SEALED BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE
WHERE THE PROJECT IS LOCATED.
2.) COMPLY WITH ALL LOADING REQUIREMENTS AS ESTABLISHED BY THE BUILDING CODE.
3.) LIMIT MAXIMUM LATERAL DEFLECTION TO 1/600 OF SPAN WHERE EXTERIOR FINISH
MATERIAL IS STONE OR MASONRY, 1/720 FOR STONE, AND 1/360 OF SPAN OTHERWISE.
4.) REFER TO ARCHITECTURAL DRAWINGS FOR DIMENSIONAL REQUIREMENTS, OPENING
LOCATIONS, ETC., AND TO SPECIFICATION FOR ADDITIONAL REQUIREMENTS. STUDS SHALL
BE DETAILED TO ACCOMMODATE MOVEMENT OF THE STRUCTURE THROUGH THE USE OF
VERTICAL SLIDE CLIPS, SLIP CONNECTIONS, ETC.
J. POWDER ACTUATED FASTENERS
1.) ALL POWDER ACTUATED FASTENERS SHALL BE APPROVED FOR TYPE, APPLICATION AND
INSTALLATION AND SHALL HAVE AN APPROVED ICBO RESEARCH REPORT NUMBER.
2.) FASTENERS SHALL NOT BE INSTALLED UNTIL THE CONCRETE HAS REACHED ITS DESIGN
STRENGTH.
3.) FASTENERS SHALL NOT BE INSTALLED IN CONCRETE WHERE THE THICKNESS IS LESS
THAN THREE TIMES THE PENETRATION REQUIRED, EXCEPT 1 1/8" PENETRATION IN 3-
1/4" THICK FLOOR SLAB IS ACCEPTABLE.
4.) THE MINIMUM DISTANCE FROM THE EDGE OF CONCRETE TO CENTER OF ANCHOR IS 3 INCHES.
5.) FASTENERS IN THE UNDERSIDE OF CONCRETE ON METAL DECKING SHALL BE PLACED IN
THE HIGH FLUTE PORTION OF THE SLAB.
6.) WHEN INSTALLING POWDER DRIVEN PINS IN EXISTING NON-PRESTRESSED REINFORCED
CONCRETE, USE CARE AND CAUTION TO AVOID CUTTING OR DAMAGING THE EXISTING
REINFORCING BARS. WHEN INSTALLING THEM INTO EXISTING PRESTRESSED CONCRETE
(PRE- OR POST-TENSIONED). LOCATE THE PRESTRESSED TENDONS BY USING A NON-
DESTRUCTIVE METHOD PRIOR TO INSTALLATION. EXERCISE EXTREME CARE AND CAUTION
TO AVOID CUTTING OR DAMAGING THE TENDONS DURING INSTALLATION. MAINTAIN A
CLEARANCE OF 1 INCH BETWEEN THE REINFORCEMENT AND THE PIN.
D. EXPANSION ANCHORS
1.) EXPANSION ANCHORS SHALL BE A SINGLE-END EXPANSION SHIELD ANCHOR WHICH COMPLIES
WITH THE DESCRIPTIVE PART OF FEDERAL SPECIFICATION A-A 1923A, TYPE 4, FOR WEDGE
ANCHORS. WEDGE ANCHORS SHALL BE HILTI KWIK BOLT TZ. ANCHORS SHALL BE BY HILTI
FASTENING SYSTEMS OF TULSA, OK. (ICC ES REPORTS ESR-1917) OR EQUAL.
2.) ANCHORS SHALL BE ZINC PLATED UNLESS SPECIFICALLY NOTED AS STAINLESS STEEL ON
THE PLAN DETAILS.
3.) WHEN DETAILS OF SECTIONS INDICATE EXPANSION ANCHORS BUT NO SIZE, PROVIDE
ANCHORS WITH 3/4" (20mm) DIAMETER.
4.) WHEN INSTALLING DRILLED-IN-ANCHORS, USE CARE AND CAUTION TO AVOID CUTTING OR
DAMAGING THE EXISTING REINFORCING BARS. WHEN INSTALLING THEM INTO
CONCRETE WITH STRESSING TENDONS (POST-TENSIONED OR PRE-TENSIONED), LOCATE
THE TENDONS BY USING A NON-DESTRUCTIVE METHOD PRIOR TO INSTALLATION. EXERCISE
EXTREME CARE AND CAUTION AND MAINTAIN AT LEAST 1" CLEAR BETWEEN THE TENDON
AND THE ANCHOR. CUTTING A TENDON CAN CAUSE COLLAPSE.
G. STRUCTURAL STEEL
1.) STEEL FRAMING DESIGNATIONS AND SYMBOLS ARE DEFINED IN THE STRUCTURAL STEEL
SYMBOL LEGEND.
2.) ALL FIELD BOLTED SHEAR CONNECTIONS SHALL BE MADE WITH MINIMUM 3/4"(20) DIAMETER
F1852 BOLTS, UNLESS NOTED OTHERWISE. ALL BOLTS SHALL BE FULLY PRETENSIONED AND
INSPECTED USING TENSION CONTROL TWIST-OFF STYLE BOLTS. UNLESS SPECIFICALLY
INDICATED AS SLIP CRITICAL OR PRETENSIONED, ALL JOINTS SHALL BE DESIGNATED AS
SNUG TIGHT. ROUTINE OBSERVATION TO VERIFY THE SPLINED ENDS ARE PROPERLY
SEVERED DURING INSTALLATION IS REQUIRED FOR ALL BOLTS.
3.) PLACE NON-SHRINK GROUT UNDER ALL COLUMN BASE PLATES BEFORE PLACING ANY
ELEVATED SLABS.
4.) WHERE THE WORK OF OTHER TRADES REQUIRES CUTS OR OPENINGS TO BE MADE IN
STRUCTURAL STEEL MEMBERS, APPROVAL SHALL BE OBTAINED FROM THE ENGINEER.
SUCH OPENINGS SHALL BE MADE IN THE SHOP AND CLEARLY INDICATED ON THE SHOP
DRAWING.
5.) E70XX ELECTRODES SHALL BE USED FOR ALL WELDING. PROPERLY QUALIFIED WELDERS
SHALL PERFORM ALL WELDING, AS PRESCRIBED UNDER "STANDARD QUALIFICATION
PROCEDURE" OF THE AMERICAN WELDING SOCIETY.
6.) WELD LENGTHS CALLED FOR ON THE PLANS ARE THE NET EFFECTIVE LENGTH REQUIRED.
WHERE FILLET WELD SYMBOL IS GIVEN WITHOUT INDICATION OF SIZE, USE MINIMUM SIZE
WELDS AS SPECIFIED BY AISC OR 3/16", WHICH EVER IS GREATER.
7.) ALL GROOVE WELDS INDICATED ON PLANS AND SECTIONS SHALL BE COMPLETE JOINT
PENETRATION WELDS (CJP) UNLESS SPECIFICALLY INDICATED TO BE PARTIAL
PENETRATION WELDS.
8.) CANTILEVER BEAM SIZE MATCHES MAIN SPAN BEAM SIZE UNLESS NOTED OTHERWISE.
9.) COMPOSITE BEAMS ARE DESIGNED FOR UNSHORED CONSTRUCTION. BEAMS SHALL BE
FABRICATED WITH THE CAMBER INDICATED ON THE PLANS. BEAMS WITHOUT SPECIFIED
CAMBER SHALL BE ERECTED WITH THE STANDARD MILL TOLERANCE CAMBER UP.
K. MASONRY
1.) ALL CONCRETE MASONRY UNITS SHALL BE HOLLOW BLOCK MADE WITH NORMAL WEIGHT
AGGREGATE IN ACCORDANCE WITH ASTM C33.
2.) ALL MASONRY WALLS SHALL BE REINFORCED UNLESS NOTED OTHERWISE, THE FOLLOWING
SHALL CONSTITUTE MINIMUM REINFORCEMENT REQUIREMENTS:
WALL SIZE VERTICAL REINFORCEMENT
6" 1-#5 AT 48" CENTERED
8" 1-#6 AT 48" CENTERED
10 & 12" 1-#7 AT 48" EACH FACE
3.) PROVIDE VERTICAL REINFORCEMENT AS INDICATED. IN ADDITION, PROVIDE VERTICAL BARS
AROUND ALL OPENINGS, AT CORNERS, ANCHORED INTERSECTIONS AND AT END OF WALL
PANELS.
4.) CONTINUOUS BOND BEAMS SHALL BE PLACED IN ONE OF THE TOP THREE COURSES OF
ALL WALLS. BOND BEAMS SHALL BE REINFORCED AS FOLLOWS:
WALL SIZE REINFORCEMENT
6" 1-#6 8" 2-#5 10" & 12" 2-#6
5.) ALL REINFORCING SHALL HAVE A MINIMUM COVERAGE OF ONE BAR DIAMETER (1/2"MIN.)
OF GROUT. CENTERED BARS SHALL BE SECURELY PLACED IN THE CENTER OF A CELL.
EACH FACE BARS SHALL BE PLACED 1" CLEAR OF THE FACE SHELL. WHERE TWO
LAYERS ARE REQUIRED IN 8" OR SMALLER BLOCK, USE ONE BAR IN EACH OF TWO
ADJACENT CELLS.
6.) CONTROL JOINTS: MAXIMUM SPACING OF CONTROL JOINTS SHALL BE AS FOLLOWS,
UNLESS NOTED OTHERWISE. (DO NOT PLACE CONTROL JOINTS IN SHEAR WALLS. SEE
ARCHITECTURAL DRAWINGS FOR ADDITIONAL INFORMATION ON LOCATION OF CONTROL
JOINTS):
EXTERIOR WALLS INTERIOR WALLS
30 FT 40 FT
7.) ALL MASONRY WALLS SHOWN ON STRUCTURAL DRAWINGS ARE LOAD BEARING, UNLESS
NOTED OTHERWISE. REFER TO ARCHITECTURAL DRAWINGS FOR NON-LOAD BEARING
MASONRY WALLS.
8.) REFER TO MECHANICAL, ELECTRICAL, PLUMBING AND ARCHITECTURAL DRAWINGS FOR
LOCATIONS OF CONDUIT, PIPING, DUCTWORK, AND OPENINGS IN MASONRY WALLS.
PROVIDE ADDITIONAL REINFORCEMENT AT OPENINGS OR SLEEVES AS INDICATED. DO NOT
CUT REINFORCEMENT.
9.) CONTINUOUS REINFORCING IN WALLS MAY BE SPLICED AS REQUIRED, PROVIDED BARS
ARE OF THE LONGEST PRACTICAL LENGTH AND ALL SPLICES ARE SHOWN ON
REINFORCING SHOP DRAWINGS. WHEREVER POSSIBLE, SPLICES SHALL BE STAGGERED.
10.) LAP ALL REINFORCING BARS IN MASONRY 40 (48 for OSHPD) BAR DIAMETERS AT
SPLICES. HORIZONTAL MASONRY REINFORCING SHALL BE CONTINUOUS AROUND ALL
CORNERS AND INTERSECTIONS.
11.) ALL VERTICAL REINFORCING SHALL BE CONTINUOUS FOR FULL HEIGHT OF WALL AND
DOWELED INTO FOOTING OR SLAB ON GRADE BELOW AND EXTENDED INTO BOND BEAMS
ABOVE. CONTINUITY MAY BE ESTABLISHED WITH LAPPED SPLICES MEETING ALL INDICATED
REQUIREMENTS.
12.) GROUT CELLS SOLID IN ALL WALLS UNLESS NOTED OTHERWISE. REINFORCING SHALL BE
SECURELY HELD IN PLACE. GROUT IN 2'0" MAXIMUM LIFTS.
13.) NO PIPES OR DUCTS SHALL BE EMBEDDED IN MASONRY UNLESS NOTED OR DETAILED
SPECIFICALLY.
14.) CELLS CONTAINING BOLTS SHALL BE GROUTED SOLID WITH AT LEAST 1/2" GROUT
COVERAGE BETWEEN THE BOLT AND THE MASONRY AT THE BLOCK FACE.
H. COMPOSITE SLABS AND DECKS
1.) CONCRETE WITH CALCIUM CHLORIDE OR ANY ADMIXTURE CONTAINING CHLORIDES SHALL
NOT BE USED WITH COMPOSITE STEEL DECK.
2.) COMPOSITE BEAMS ARE DESIGNED FOR UNSHORED CONSTRUCTION. BEAMS SHALL BE
FABRICATED WITH THE CAMBER INDICATED ON THE PLANS. BEAMS WITHOUT SPECIFIED
CAMBER SHALL BE ERECTED WITH THE STANDARD MILL TOLERANCE CAMBER UP.
3.) PROVIDE COMPOSITE DECK LAYOUT THAT IS CONTINUOUS OVER THREE OR MORE SUPPORTS.
COMPLY WITH DECK MANUFACTURER SHORING REQUIREMENTS FOR OTHER DECK LAYOUTS.
4.) TO COMPENSATE FOR DEFLECTION OF THE STRUCTURE UNDER THE LOAD OF FRESHLY PLACED
CONCRETE, THE SLAB THICKNESS SHALL BE INCREASED ACCORDINGLY TO PROVIDE A LEVEL
SURFACE WITHIN TOLERANCE. ADDITIONAL CONCRETE SHALL BE PLACED AT NO ADDITIONAL
COST TO THE OWNER. MAXIMUM ADDITIONAL THICKNESS OF 1.5" ASSUMED IN PARABOLIC
PROFILE ACROSS BAY.
5.) CORE DRILLED OR CUT OPENINGS IN COMPOSITE SLABS SHALL NOT EXCEED 10" IN ANY
DIMENSION. LARGER OPENINGS, WHEN REQUIRED SHALL BE BOXED OUT AND REINFORCED
PER TYPICAL UNFRAMED OPENING DETAIL.
6.) CORE DRILLED OR CUT OPENINGS SHALL NOT BE PLACED CLOSER THAN 1 OPENING DIAMETER
OR WIDTH TO ANY BEAM NOR SPACED CLOSER THAN 2 OPENING DIAMETERS OR WIDTHS. WHEN
TWO ADJACENT OPENINGS ARE OF A DIFFERENT SIZE. SPACING SHALL BE BASED UPON THE
LARGER SIZE.
7.) WHEN TOTAL WIDTH OF ADJACENT OPENINGS REQUIRED IS LARGER THAN 30" OR WHEN
REQUIRED SPACING OF OPENINGS CANNOT BE MET, CORED OR CUT OPENINGS SHALL BE
SUPPOTRED ALONG ALL EDGES. PROVIDE W10 X 12 SUPPORT BEAMS AT THESE LOCATIONS.
LOCATE BEAMS 6" CLEAR OF OPENING EDGES.
8.) ELECTRICAL CONDUIT IN SLAB ON METAL DECK SHALL NOT BE PERMITTED.
9.) ALL CONTINUOUS REBARS SHALL HAVE CLASS 'B' LAP SPLICES, TYPICAL. STAGGER
SPLICES AS REQUIRED.
10.) ADDITIONAL REINFORCING BARS SHOWN ON PLAN ARE IN ADDITION TO THOSE NOTED IN THE
COMPOSITE DECK CONFIGURATION TABLE AND AS SHOWN ON TYPICAL AND SPECIFIC DETAILS.
11.) CENTER ALL ADDITIONAL SLAB REINFORCING IN THE SLAB ABOVE THE DECK, TYPICAL.
12.) REINFORCING SHALL BE FULLY DEVELOPED PAST PERPENDICULAR REINFORCING AT CORNERS
AND OPENINGS, TYPICAL UNLESS NOTED OTHERWISE.
1/
2" 1"
2"
Project Number
Original Issue
Sheet Number
Sheet Name
Project Status
Project Designer
Project Manager
Project Architect
Landscape Architect
Civil Engineer
Structural Engineer
Mechanical Engineer
Electrical Engineer
Interior Designer
Equipment Planner
Wayfinding
Sheet Reviewer
A
B
C
D
12345
A
B
C
D
Plumbing Engineer
/6
/2
:0 8:
A
M C
:\r vt
\2
0\
-S
-B N
L- E
IC
_C
E N
T R
A Lv
_M in G ao .L i.r vt
S-001
GENERAL NOTES AND
ABBREVIATIONS
Brookhaven National Laboratory Electron Ion Collider
Concept Design 100% Review Submittal
10235960
09/25/20
NOT FOR
CONSTRUCTION
HDR Architecture HDR Arlington 3001 Washington Blvd, Suite 200 Arlington, VA 22201
Author
Gabriela Kleiman
Tyler Dye
Kevin LeMans
Joseph Dennis
Joseph Krzyzewski
Phil…
This is the start of the file's text. The full file is on GovTribe.