ATTACHMENT E - BLDG-P691-HSF-1290140-V3.pdf
PDF 29 MB Posted
- Solicitation number
- 6007134
About this file
This document is Attachment E to the federal contract opportunity for the P691 Phase I, Aircraft Development and Maintenance Facility project. The project secures site development and construction services for a Sonobuoy Storage Building and an Air Ops Storage Building, with an option for a Hazmat building if needed. It also includes a Furniture, Fixtures, and Equipment (FF&E) option for the acquisition and placement of various moveable items. This opportunity is restricted to the 10 small businesses participating in the NAVFAC WASHINGTON Gold Small Business Multiple Award Construction Contract (GOLD SB MACC). The solicitation number is 6007134, and the project is being conducted by the Department of the Navy Naval Facilities Engineering Command.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S T
E M
S C
O M
M A
N D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D W
A S
H
IN
G T
O N
W A
S H
IN
G
T O
N N
A V
Y Y
A R
D
D .C
AS NOTED
3500 Parkway Lane, Suite 500 Peachtree Corners, GA 30092
W A
S H
IN
G
T O
N D
C C
O R
E
N A
V A
L A
IR
S
T A
T
IO
N P
A T
U X
E N
T R
IV
E
R S
T . M
A R
Y 'S
C O
U N
T Y
, M D
F Y
M
IL
C O
N P
1737036
CONTROLLED UNCLASSIFIED INFORMATION
C O
N T
R O
L L E
D U
N C
L A
S S
IF
IE
D I
N F
O R
M A
T
IO
N
CONTROLLED UNCLASSIFIED INFORMATION
C O
N T
R O
L L E
D U
N C
L A
S S
IF
IE
D I
N F
O R
M A
T
IO
N
PM/CN
TC
SS
04/04/2024
GR
/3
/2
:4 :1
A
M
C U s e rs
\e ri n
.a d a m s o n \O n e D ri v e
M ic h a e l B a k e r
In te rn a ti o n a l\ D o c u m e n ts
\B L D
G -P
-1
-G
V
E ri n
.A d a m s o n
.r v t
V3 G-000
P R
O
JE
C T
C O
V E
R S
H E
E T
JH
13150146
EMA EMA
G -0
100% FINAL SUBMITTAL
PROJECT COVER SHEET
NAVAL AIR STATION PATUXENT RIVER, MARYLAND
100% FINAL SUBMITTAL
29 SEPTEMBER 2023
DEPARTMENT OF THE NAVY
NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND
VOLUME 3 - HAZMAT BUILDING
Controlled By: PEO (A) / PMA 271 CUI Catergory(ies): CUI/SP-CTI Limited Dissemination Control: FEDCON POC: Facility LEM PMA-271
(301) 757-0335
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
Erin.Adamson Snapshot
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S T
E M
S C
O M
M A
N D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D W
A S
H
IN
G T
O N
W A
S H
IN
G
T O
N N
A V
Y Y
A R
D
D .C
AS NOTED
3500 Parkway Lane, Suite 500 Peachtree Corners, GA 30092
W A
S H
IN
G
T O
N D
C C
O R
E
N A
V A
L A
IR
S
T A
T
IO
N P
A T
U X
E N
T R
IV
E
R S
T . M
A R
Y 'S
C O
U N
T Y
, M D
F Y
M
IL
C O
N P
1737036
CONTROLLED UNCLASSIFIED INFORMATION
C O
N T
R O
L L E
D U
N C
L A
S S
IF
IE
D I
N F
O R
M A
T
IO
N
CONTROLLED UNCLASSIFIED INFORMATION
C O
N T
R O
L L E
D U
N C
L A
S S
IF
IE
D I
N F
O R
M A
T
IO
N
PM/CN
TC
SS
04/04/2024
GR
/3
/2
:4 :1
A
M
C U s e rs
\e ri n
.a d a m s o n \O n e D ri v e
M ic h a e l B a k e r
In te rn a ti o n a l\ D o c u m e n ts
\B L D
G -P
-1
-G
V
E ri n
.A d a m s o n
.r v t
V3 G-001
H A
Z M
A T
B U
IL
D
IN
G
C O
V E
R S
H E
E T
V
O
LU
M E
JH
13150147
EMA EMA
G -0
100% FINAL SUBMITTAL
VOLUME 3 - HAZMAT BUILDING
NAVAL AIR STATION PATUXENT RIVER, MARYLAND
DEPARTMENT OF THE NAVY
NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND
V O
LU
M
E
H
A Z
M A
T B
U
IL
D
IN
G
VICINITY MAP
LOCATION MAP
PROJECT LOCATION(S)
PROJECT LOCATION
Controlled By: PEO (A) / PMA 271 CUI Catergory(ies): CUI/SP-CTI Limited Dissemination Control: FEDCON POC: Facility LEM PMA-271
(301) 757-0335
100% FINAL SUBMITTAL
29 SEPTEMBER 2023
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S T
E M
S C
O M
M A
N D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D W
A S
H
IN
G T
O N
W A
S H
IN
G
T O
N N
A V
Y Y
A R
D
D .C
AS NOTED
3500 Parkway Lane, Suite 500 Peachtree Corners, GA 30092
W A
S H
IN
G
T O
N D
C C
O R
E
N A
V A
L A
IR
S
T A
T
IO
N P
A T
U X
E N
T R
IV
E
R S
T . M
A R
Y 'S
C O
U N
T Y
, M D
F Y
M
IL
C O
N P
1737036
CONTROLLED UNCLASSIFIED INFORMATION
C O
N T
R O
L L E
D U
N C
L A
S S
IF
IE
D I
N F
O R
M A
T
IO
N
CONTROLLED UNCLASSIFIED INFORMATION
C O
N T
R O
L L E
D U
N C
L A
S S
IF
IE
D I
N F
O R
M A
T
IO
N
PM/CN
TC
SS
04/04/2024
GR
/3
/2
:4 :1
A
M
C U s e rs
\e ri n
.a d a m s o n \O n e D ri v e
M ic h a e l B a k e r
In te rn a ti o n a l\ D o c u m e n ts
\B L D
G -P
-1
-G
V
E ri n
.A d a m s o n
.r v t
V3 G-002
D R
A W
IN
G
IN
D
E X
JH
13150148
EMA EMA
G -0
100% FINAL SUBMITTAL
SHEET INDEX
SHEET
NO.
NAVFAC
DRAWIN
G NO.
SHEET INFORMATION
NUMBER NAME
GENERAL
1 13150146 G-000 PROJECT COVER SHEET
2 13150147 G-001 HAZMAT BUILDING COVER SHEET - VOLUME 3
3 13150148 G-002 DRAWING INDEX
SHEET INDEX - VOLUME 3
SHEET
NO.
NAVFAC
DRAWING
NO.
SHEET INFORMATION
NUMBER NAME
ELECTRICAL
71 13150216 E-001 ELECTRICAL - NOTES, SYMBOLS, AND ABBREVIATIONS
72 13150217 ES101 ELECTRICAL - SITE UTILITY PLAN
73 13150218 ES501 ELECTRICAL - SITE DETAILS
74 13150219 ES502 ELECTRICAL - SITE DETAILS
75 13150220 ES503 ELECTRICAL - SITE DETAILS
76 13150221 EH101 HAZARDOUS LOCATIONS PLAN
77 13150222 EG101 ELECTRICAL - GROUNDING PLAN
78 13150223 EG102 ELECTRICAL - LIGHTNING PROTECTION PLAN
79 13150224 EG501 ELECTRICAL - GROUNDING DETAILS
80 13150225 EG502 ELECTRICAL - LIGHTNING PROTECTION DETAILS
81 13150226 EL101 LIGHTING - 1ST FLOOR PLAN
82 13150227 EP101 POWER - 1ST FLOOR PLAN
83 13150228 E-401 ELECTRICAL - ENLARGED PLANS
84 13150229 E-501 ELECTRICAL - LIGHTING CONTROL DETAILS
85 13150230 E-502 ELECTRICAL - LIGHT FIXTURE DETAILS
86 13150231 E-601 ELECTRICAL - LIGHTING FIXTURE SCHEDULE
87 13150232 E-602 ELECTRICAL - SINGLE LINE DIAGRAM AND PANEL SCHEDULES
TELECOMMUNICATIONS
88 13150233 T-001 TELECOMMUNICATIONS SYMBOLS, SCHEDULES, & NOTES
89 TS101 TELECOMMUNICATIONS - SITE UTILTY PLAN
90 13150235 T-101 TELECOMMUNICATIONS - 1ST FLOOR PLAN
91 13150236 T-401 TELECOMMUNICATIONS - ENLARGED PLANS
92 13150237 T-501 TELECOMMUNICATIONS - DETAILS
93 13150238 T-502 TELECOMMUNICATIONS - DETAILS
94 13150239 T-601 TELECOMMUNICATIONS - DIAGRAMS
SHEET INDEX - VOLUME 3
SHEET
NO.
NAVFAC
DRAWING
NO.
SHEET INFORMATION
NUMBER NAME
GENERAL
4 13150149 GI001 BUILDING CODE ANALYSIS
5 13150150 GI100 LIFE SAFETY - CODE COMPLIANCE PLAN
6 13150151 GI101 LIFE SAFETY - FIRST FLOOR PLAN
HAZARDOUS
7 13150152 H-111 HAZARDOUS - PLAN
STRUCTURAL
8 13150153 S-001 DESIGN CRITERIA AND GENERAL NOTES
9 13150154 S-002 GENERAL NOTES, ABBREVIATIONS AND SYMBOLS
10 13150155 S-101 FOUNDATION PLAN
11 13150156 S-301 FOUNDATION SECTIONS
12 13150157 S-302 FOUNDATION SECTIONS
13 13150158 S-401 ENLARGED PLANS AT CONTAINMENT AREAS
14 13150159 S-501 FOUNDATION AND SLAB TYPICAL DETAILS
15 13150160 S-502 FOUNDATION AND SLAB TYPICAL DETAILS
16 13150161 S-503 MASONRY TYPICAL DETAILS
17 13150162 S-601 STRUCTURAL SCHEDULES
18 13150163 S-602 PIER SCHEDULES AND DETAILS
19 13150164 S-603 PIER DETAILS
ARCHITECTURE
20 13150165 AE001 ARCHITECTURAL NOTES AND SYMBOLS
21 13150166 AE002 TYPICAL ABA DETAILS & MOUNTING HEIGHTS
22 13150167 AE101 FIRST FLOOR PLAN
23 13150168 AE105 FIRST FLOOR REFLECTED CEILING PLAN
24 13150169 AE109 ROOF PLAN
25 13150170 AE201 NORTH AND SOUTH EXTERIOR ELEVATIONS
26 13150171 AE202 EAST AND WEST EXTERIOR ELEVATIONS
27 13150172 AE301 BUILDING SECTIONS
28 13150173 AE311 WALL SECTIONS
29 13150174 AE401 ENLARGED TOILET ROOM
30 13150175 AE501 EXTERIOR DETAILS
31 13150176 AE510 INTERIOR PARTITION TYPE SCHEDULE AND DETAILS
32 13150177 AE601 DOOR SCHEDULE AND LOUVER TYPES
33 13150178 AE602 DOOR DETAILS
INTERIORS
34 13150179 IN001 INTERIORS - FINISH, FURNITURE AND SIGNAGE SCHEDULES AND NOTES
35 13150180 IN101 INTERIORS - FINISH, FURNITURE AND SIGNAGE PLAN, DESK TYPICAL AND LEGENDS
36 13150181 IN102 INTERIORS - DETAILS AND SIGNAGE DETAILS
FIRE PROTECTION
37 13150182 FA001 FIRE ALARM - GENERAL NOTES, ABBREVIATIONS, & SYMBOLS
38 13150183 FA002 FIRE ALARM - SEQUENCE OF OPERATIONS
39 13150184 FA101 FIRE ALARM - FIRST FLOOR PLAN
40 13150185 FA501 FIRE ALARM - DETAILS
41 13150186 FA701 FIRE ALARM - RISER DIAGRAM
42 13150187 FX001 FIRE PROTECTION GENERAL NOTES, ABBREVIATIONS, & SYMBOLS
43 13150188 FX101 FIRE PROTECTION - FIRST FLOOR PLAN
PLUMBING
44 13150189 P-001 PLUMBING GENERAL NOTES, ABBREVIATIONS & SYMBOLS
45 13150190 PU111 PLUMBING - UNDERGROUND PLAN
46 13150191 P-111 PLUMBING - 1ST FLOOR PLAN
47 13150192 P-151 PLUMBING - ROOF PLAN
48 13150193 P-401 PLUMBING - ENLARGED PLANS
49 13150194 P-501 PLUMBING - DETAILS
50 13150195 P-601 PLUMBING - SCHEDULES
51 13150196 P-701 PLUMBING - RISER DIAGRAMS
52 13150197 P-702 PLUMBING - RISER DIAGRAMS
MECHANICAL
53 13150198 M-001 MECHANICAL - SYMBOLS AND ABBREVIATIONS
54 13150199 M-002 MECHANICAL - GENERAL NOTES
55 13150200 MH111 HVAC - 1ST FLOOR PLAN
56 13150201 MP111 PIPING - 1ST FLOOR PLAN
57 13150202 M-401 MECHANICAL - ENLARGED PLANS
58 13150203 M-501 MECHANICAL - DETAILS
59 13150204 M-502 MECHANICAL - DETAILS
60 13150205 M-503 MECHANICAL - DETAILS
61 13150206 M-601 MECHANICAL - SCHEDULES
62 13150207 M-602 MECHANICAL - SCHEDULES
63 13150208 M-701 MECHANICAL - DIAGRAMS
64 13150209 M-801 MECHANICAL - CONTROLS
65 13150210 M-802 MECHANICAL - CONTROLS
66 13150211 M-803 MECHANICAL - CONTROLS
67 13150212 M-804 MECHANICAL - CONTROLS
68 13150213 M-805 MECHANICAL - CONTROLS
69 13150214 M-806 MECHANICAL - CONTROLS
70 13150215 M-807 MECHANICAL - CONTROLS
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
FIRE PROTECTION/LIFE SAFETY CODE SUBMITTAL
1. PROJECT NAME
P691 AIRCRAFT HANGAR AND OUTBUILDINGS - HAZARDOUS MATERIALS WASTE STORAGE FACILITY
2. PROJECT DESCRIPTION
THE SINGLE STORY BUILDING CONSISTS OF BUSINESS AND STORAGE OCCUPANCIES. THE BUILDING CONTAINS ADMINISTRATIVE SPACES, A
HAZARDOUS WASTE STORAGE BAY, AND BUILDING EQUIPMENT SPACES.
THE FACILITY HAS BEEN ANALYZED FOR LIFE SAFETY AND FIRE PROTECTION REQUIREMENTS USING THE CODES AND STANDARDS LISTED BELOW. THE IBC WILL BE USED FOR FIRE RESISTANCE REQUIREMENTS, ALLOWABLE FLOOR AREA, BUILDING HEIGHT LIMITATIONS, BUILDING SEPARATION DISTANCE REQUIREMENTS, BUILDING CONSTRUCTION TYPE, AND OCCUPANCY SEPARATION REQUIREMENTS. THE APPLICABLE NFPA CODES AND STANDARDS WILL BE USED FOR DETERMINING BUILDING CONSTRUCTION RELATED TO EGRESS AND SAFETY TO LIFE AS WELL AS FIRE RESISTANCE RATINGS OF NON-BEARING PARTITIONS. OCCUPANCY DEFINITIONS OF NFPA WILL BE USED TO
DETERMINE MEANS OF EGRESS REQUIREMENTS.
3. APPLICABLE CODES AND STANDARDS
• UFC 1-200-01 - DOD BUILDING CODE, 01 SEPTEMBER 2022 WITH CHANGE 1, 24 FEBRUARY 2023
• UFC 3-600-01 - FIRE PROTECTION ENGINEERING FOR FACILITIES, 8 AUGUST 2016 WITH CHANGE 6, 06 MAY 2021
• UFC 4-010-01 - DOD MINIMUM ANTITERRORISM STANDARDS FOR BUILDINGS, 12 DECEMBER 2018 WITH CHANGE 1, 19 AUGUST 2020
• FC 1-300-09N - NAVY AND MARINE CORPS DESIGN PROCEDURES WITH CHANGE 6, 09 JULY 2021
• NFPA 1 - 2021 EDITION - FIRE CODE
• NFPA 10 - 2022 EDITION - STANDARD FOR PORTABLE FIRE EXTINGUISHERS
• NFPA 13 - 2022 EDITION - STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS
• NFPA 24 - 2022 EDITION - STANDARD FOR THE INSTALLATION OF PRIVATE FIRE SERVICE MAINS
• NFPA 30 - 2021 EDITION - FLAMMABLE AND COMBUSTIBLE LIQUIDS CODE
• NFPA 70 - 2023 EDITION - NATIONAL ELECTRIC CODE
• NFPA 72 - 2022 EDITION - NATIONAL FIRE ALARM AND SIGNALING CODE
• NFPA 80 - 2022 EDITION - STANDARD FOR FIRE DOORS AND FIRE WINDOWS
• NFPA 90A - 2021 EDITION - STANDARD FOR THE INSTALLATION OF AIR-CONDITIONING AND VENTILATION SYSTEMS
• NFPA 101 - 2021 EDITION - LIFE SAFETY CODE
• NFPA 291 - 2022 EDITION - RECOMMENDED PRACTICE FOR FIRE FLOW TESTING AND MARKING OF HYDRANTS
• NFPA 400 - 2022 EDITION - HAZARDOUS MATERIALS CODE
• IBC 2018 EDITION - INTERNATIONAL BUILDING CODE
4. OCCUPANCY CLASSIFICATION
THE BUILDING CONSISTS OF SEVERAL BAYS WITHIN THE HAZARDOUS WASTE STORAGE AREA FOR VARIOUS TYPES OF MATERIALS. THE BUILDING FUNCTIONS AS A 90 DAY HAZARDOUS WASTE STORAGE FACILITY AND RECEIVES SHIPMENTS FROM DIFFERENT AREAS OF THE BASE PRIOR TO SENDING THE MATERIALS OFF BASE. REFER TO SECTION 27 FOR ADDITIONAL INFORMATION. DUE TO THE NATURE OF THE BUILDING, THE HAZARDOUS MATERIAL STORAGE AREA IS DESIGNATED AS AN H-3 OCCUPANCY SINCE IT IS LIKELY THAT THE MAQ WILL BE
EXCEEDED DURING THE LIFETIME OF THE BUILDING.
5. CONSTRUCTION TYPE (IBC SECTION 602.2)
ALL NEW CONSTRUCTION WILL BE OF TYPE II-B.
6. BUILDING AREA LIMITATIONS (IBC TABLE 506.2)
NOTES:
1. ACTUAL BUILDING SQUARE FOOTAGE IS LESS THAN THE ALLOWABLE AREA FOR THE MOST RESTRICTIVE OCCUPANCY PRIOR TO
THE ADDITION OF THE FRONTAGE ALLOWANCE INCREASE, THEREFORE, THE FRONTAGE ALLOWANCE INCREASE IS NOT REQUIRED.
2. STORAGE ROOMS LESS THAN 100 SQUARE FEET SHALL BE CONSIDERED ACCESSORY TO ANOTHER OCCUPANCY PER IBC 311.1.1.
7. BUILDING HEIGHT LIMITATIONS (IBC TABLES 504.3, 504.4)
THE BUILDING HEIGHT IS ONE STORY (24 FEET).
8. MIXED USE AND OCCUPANCY SEPARATIONS (IBC SECTION 508)
THE FACILITY IS CLASSIFIED AS NON-SEPARATED MIXED USE.
9. FIRE RESISTIVE REQUIREMENTS (IBC TABLES 601, 602)
PRIMARY STRUCTURAL FRAME 0 HOUR RATING
EXTERIOR BEARING WALLS 0 HOUR RATING*
INTERIOR BEARING WALLS 0 HOUR RATING
EXTERIOR NON-BEARING WALLS AND PARTITIONS 0 HOUR RATING*
INTERIOR NON-BEARING WALLS AND PARTITIONS 0 HOUR RATING
FLOOR CONSTRUCTION AND SECONDARY MEMBERS 0 HOUR RATING
ROOF CONSTRUCTION AND SECONDARY MEMBERS 0 HOUR RATING
*TAKES INTO ACCOUNT THE FIRE SEPARATION DISTANCE REQUIREMENT OF TABLE 602 AND UFC 3-600-01 SECTION 4-20.3. THERE IS GREATER THAN 50 FEET OF SEPARATION BETWEEN THE HAZMAT FACILITY AND THE NEAREST FACILITY.
10. PROTECTION FROM HAZARDS (NFPA 101, UFC 4-211-01)
THE HAZARDOUS AREA WILL BE SEPARATED FROM THE ADMINISTRATION AREA OF THE BUILDING BY A 2 HOUR FIRE BARRIER IN
ACCORDANCE WITH UFC 3-600-01 SECTION 4-20.3.1 AND NFPA 400 SECTION 6.2.1.3.
11. OPENING PROTECTION AND PENETRATION REQUIREMENTS (NFPA 101, CHAPTER 8)
PENETRATIONS FOR CABLES, CONDUITS, PIPES, AND SIMILAR ITEMS TO ACCOMMODATE ELECTRICAL, MECHANICAL, PLUMBING, AND COMMUNICATIONS SYSTEMS THAT PASS THROUGH FIRE BARRIERS MUST BE PROTECTED BY APPROVED FIRESTOP SYSTEMS OR DEVICES TESTED IN ACCORDANCE WITH ASTM E814 OR ANSI / UL 1479. JOINTS MADE WITHIN OR AT THE PERIMETER OF FIRE BARRIERS MUST BE PROTECTED WITH A SMOKE-TIGHT JOINT SYSTEM THAT IS CAPABLE OF LIMITING THE TRANSFER OF SMOKE. JOINTS MADE WITHIN OR BETWEEN FIRE RESISTANCE-RATED ASSEMBLIES MUST BE PROTECTED WITH A JOINT SYSTEM TESTED IN ACCORDANCE WITH ASTM E1966 OR ANSI / UL 2079.
PENETRATIONS AND JOINTS THROUGH SMOKE PARTITIONS MUST BE PROTECTED BY A SYSTEM THAT IS CAPABLE OF
LIMITING THE TRANSFER OF SMOKE.
FIREBLOCKING AND DRAFTSTOPPING ARE NOT REQUIRED IN NON-COMBUSTIBLE CONCEALED SPACES PER IBC 718.
AIR-TRANSFER OPENINGS IN SMOKE PARTITIONS MUST BE PROVIDED WITH APPROVED SMOKE DAMPERS.
12. MARKING AND IDENTIFICATION OF FIRE BARRIERS (IBC SECTION 703.7)
FIRE BARRIERS SHALL BE EFFECTIVELY AND PERMANENTLY IDENTIFIED WITH SIGNS OR STENCILING. SUCH
IDENTIFICATION SHALL:
1. BE LOCATED IN ACCESSIBLE CONCEALED FLOOR, CEILING, OR ATTIC SPACE.
2. BE LOCATED WITHIN 15 FEET OF THE END OF EACH WALL AND AT INTERVALS NOT EXCEEDING 30 FEET MEASURED
HORIZONTALLY ALONG THE WALL OR PARTITIONS.
3. INCLUDE LETTERING NOT LESS THAN 3 INCHES IN HEIGHT WITH A MINIMUM 3/8 INCH STROKE IN A CONTRASTING
COLOR INCORPORATING THE SUGGESTED WORKING “FIRE BARRIER AND/OR SMOKE PARTITION – PROTECT ALL
OPENINGS” OR OTHER WORDING.
13. FIRE AND SMOKE DAMPERS (NFPA 90A)
FIRE DAMPERS WILL BE PROVIDED IN ACCORDANCE WITH NFPA 90A CHAPTER 5. FIRE DAMPERS WILL BE PROVIDED AT LOCATIONS WHERE DUCTS PENETRATE MEMBRANES IN CEILINGS OR WALLS, AND SHAFT ENCLOSURES. AIR-TRANSFER OPENINGS IN PARTITIONS REQUIRED TO HAVE A FIRE RESISTANCE RATING WILL BE PROTECTED WITH APPROVED FIRE DAMPERS. DUCT-THROUGH PENETRATIONS OF FIRE RATED PARTITIONS IN THIS PROJECT WILL BE PROTECTED WITH A LISTED FIRESTOP SYSTEM FOR THE PARTICULAR OPENING SIZE AND DUCT ASSEMBLY. AIR-TRANSFER OPENINGS IN A FIRE-RATED ASSEMBLY SHALL BE PROVIDED WITH APPROVED FIRE DAMPERS. AIR-TRANSFER OPENINGS IN SMOKE
PARTITIONS SHALL BE PROVIDED WITH APPROVED SMOKE DAMPERS.
14. INTERIOR FINISH CLASSIFICATION LIMITS (NFPA 101 A.10.2.2)
NOTES:
1. WHERE A COMPLETE AUTOMATIC SPRINKLER SYSTEM IS PROVIDED, INTERIOR WALL AND CEILING FINISH WITH A
FLAME SPREAD RATING NOT EXCEEDING CLASS C IS PERMITTED TO BE USED IN ANY LOCATION WHERE CLASS B IS REQUIRED AND WITH A RATING OF CLASS B IN ANY LOCATION WHERE CLASS A IS REQUIRED; SIMILARLY, CLASS II INTERIOR FLOOR FINISH IS PERMITTED TO BE USED IN ANY LOCATION WHERE CLASS 1 IS REQUIRED, AND NO
CRITICAL RADIANT FLUX RATING IS REQUIRED WHERE CLASS II IS REQUIRED.
15. INSULATION REQUIREMENTS (UFC 3-600-01 SECTION 8-3, IBC SECTION 2603)
THERMAL AND ACOUSTICAL INSULATION WITH A FLAME SPREAD RATING NOT HIGHER THAN 75 AND A SMOKE DEVELOPED RATING NOT HIGHER THAN 150 WILL BE USED WHEN TESTED IN ACCORDANCE WITH ASTM E84 UNLESS EXCEPTIONS OF
UFC 3-600-01 SECTION 8-3.2 ARE MET.
FOAM PLASTIC INSULATION MUST MEET THE REQUIREMENTS OF IBC SECTION 2603.
16. MEANS OF EGRESS (NFPA 101)
MEANS OF EGRESS WILL COMPLY WITH THE MOST RESTRICTIVE REQUIREMENT OF THE OCCUPANCIES PRESENT IN THE
BUILDING.
THE BUILDING IS CLASSIFIED AS A NON-SEPARATED MIXED-USE OCCUPANCY PER IBC AND A MIXED-USE OCCUPANCY PER NFPA 101. EACH PORTION OF THE BUILDING MUST BE CLASSIFIED AS ITS OWN USE IN ACCORDANCE WITH NFPA 101
SECTION 6.1.14.3.1.
MEANS OF EGRESS LIMITATIONS WILL BE IN ACCORDANCE WITH NFPA 101 TABLE A.7.6.
EXITS WILL BE DESIGNED TO MEET NFPA 101. ALL DOORS AND CORRIDORS IN HIGH HAZARD AREAS MUST BE SIZED AT 0.4 INCHES PER OCCUPANT USING THE EXIT IN ACCORDANCE WITH TABLE 7.3.3.1. ALL OTHER DOORS AND CORRIDORS MUST
BE SIZED AT 0.2 INCHES PER OCCUPANT.
EXITS SHALL BE PROVIDED SUCH THAT EXITS ARE AT LEAST 1/3 THE DIAGONAL DISTANCE OF THE BUILDING APART PER
SECTION 7.5.1.3.3.
16. MEANS OF EGRESS CONTINUED (NFPA 101)
17. OCCUPANT LOAD CALCULATION
THE OCCUPANT LOAD CALCULATION ABOVE IS NOT TO BE USED FOR THE PURPOSES OF DETERMINING ATFP OCCUPANCY. THE
BUILDING IS CONSIDERED "LOW OCCUPANCY" FOR ATFP PURPOSES.
18. DISCHARGE FROM EXITS AND EGRESS CAPACITY CALCULATION (NFPA 101)
BUILDING EXITS SHALL TERMINATE DIRECTLY AT A PUBLIC WAY IN ACCORDANCE WITH SECTION 7.7.
BASED ON AN OCCUPANT LOAD OF 13 PERSONS, 2 EXITS EACH HAVING A MINIMUM CLEAR WIDTH OF 32 INCHES ARE REQUIRED FOR THE FACILITY PER NFPA 101 SECTIONS 38.2.4, 42.2.4, AND 7.11.4. THREE EXITS WITH A MINIMUM CLEAR WIDTH OF 34 INCHES EACH ARE PROVIDED. EXITS FROM NORMALLY UNOCCUPIED OR SINGLE ROOMS ARE ALSO PROVIDED. ALL INDIVIDUAL ROOM EXITS PROVIDE ADEQUATE CAPACITY FOR THE OCCUPANT LOAD OF THE ROOM THAT THEY SERVE.
19. ILLUMINATION OF MEANS OF EGRESS (NFPA 101)
MEANS OF EGRESS WILL BE ILLUMINATED IN ACCORDANCE WITH SECTION 7.8.1.2 THROUGH 7.8.1.5.
20. EMERGENCY LIGHTING (NFPA 101)
EMERGENCY LIGHTING WILL BE PROVIDED IN ACCORDANCE WITH SECTION 7.9.1.3 AND 7.9.2.
21. MARKING OF MEANS OF EGRESS (NFPA 101)
MEANS OF EGRESS WILL HAVE SIGNS IN ACCORDANCE WITH SECTION 7.10. EMERGENCY ILLUMINATION MUST BE PROVIDED FOR A MINIMUM OF 1 ½ HOURS IN THE EVENT OF FAILURE OF NORMAL LIGHTING. THE EMERGENCY LIGHTING SYSTEM MUST BE ARRANGED TO PROVIDE THE REQUIRED ILLUMINATION AUTOMATICALLY IN THE EVENT OF ANY INTERRUPTION OF NORMAL
LIGHTING
22. PORTABLE FIRE EXTINGUISHERS (UFC 3-600-01, NFPA 10, NFPA 101)
PORTABLE FIRE EXTINGUISHERS MUST BE PROVIDED IN ACCORDANCE WITH NFPA 101 AND PLACED IN ACCORDANCE WITH
NFPA 10.
23. AUTOMATIC SPRINKLERS (UFC 3-600-01, NFPA 13)
THE BUILDING WILL BE EQUIPPED WITH A COMPLETE, AUTOMATIC WET-PIPE SPRINKLER SYSTEMS AS REQUIRED BY UFC
3-600-01 AND SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 13.
24. FIRE ALARM SYSTEM (UFC 3-600-01 AND NFPA 72)
THE BUILDING WILL BE PROVIDED WITH A COMPLETE, SUPERVISED, ADDRESSABLE, FIRE ALARM SYSTEM IN ACCORDANCE
WITH UFC 3-600-01 AND NFPA 72.
25. ANTITERRORISM AND FORCE PROTECTION REQUIREMENTS (UFC 4-010-01 SECTION 3-19)
EMERGENCY SHUTOFF SWITCHES IN THE HVAC CONTROL SYSTEM CAPABLE OF IMMEDIATE SHUTDOWN OF THE AIR DISTRIBUTION SYSTEM THROUGHOUT THE BUILDING SHALL BE PROVIDED THROUGHOUT THE BUILDING.
26. FIRE DEPARTMENT ACCESS (UFC 3-600-01, NFPA 1)
THE BUILDING IS PROVIDED WITH FIRE DEPARTMENT ACCESS ON 2 SIDES OF THE FACILITY IN ACCORDANCE WITH UFC 3-600-01 AND NFPA 1. NEW FIRE HYDRANTS ARE PROVIDED SURROUNDING THE FACILITY AT FIRE DEPARTMENT ACCESS LANES. A KNOX
BOX WILL BE PROVIDED AT THE MAIN ENTRANCE TO THE FACILITY.
27. HAZARDOUS MATERIALS (UFC 3-600-01)
BASED ON INFORMATION PROVIDED AT THE CHARRETTE, IT IS EXPECTED THAT THE BUILDING WILL EXCEED THE MAXIMUM ALLOWABLE QUANTITY FOR THE MATERIALS TYPICALLY SENT TO THE EXISTING FACILITY. TYPICAL MATERIALS THE FACILITY RECEIVES INCLUDE PAINT, LED LIGHT BULBS, JET FUEL, CLEANING SOLVENTS, ETC. THE STANDARD OPERATING PROCEDURE IS ONLY TO STORE WHAT CAN FIT IN EACH DESIGNATED BAY. MATERIALS ARE STORED ON THE FLOOR AND NOT STACKED ON
SHELVES/RACKS. ALL MATERIALS ARE STORED IN CLOSED CONTAINERS.
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S T
E M
S C
O M
M A
N D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D W
A S
H
IN
G T
O N
W A
S H
IN
G
T O
N N
A V
Y Y
A R
D
D .C
AS NOTED
3500 Parkway Lane, Suite 500 Peachtree Corners, GA 30092
W A
S H
IN
G
T O
N D
C C
O R
E
N A
V A
L A
IR
S
T A
T
IO
N P
A T
U X
E N
T R
IV
E
R S
T . M
A R
Y 'S
C O
U N
T Y
, M D
F Y
M
IL
C O
N P
1737036
CONTROLLED UNCLASSIFIED INFORMATION
C O
N T
R O
L L E
D U
N C
L A
S S
IF
IE
D I
N F
O R
M A
T
IO
N
CONTROLLED UNCLASSIFIED INFORMATION
C O
N T
R O
L L E
D U
N C
L A
S S
IF
IE
D I
N F
O R
M A
T
IO
N
PM/CN
TC
SS
04/04/2024
GR
/4
/2
:3
:3
P M
C U s e rs
\d m c c u tc h e o n \D o c u m e n ts
\B L D
G -P
-H
S F
-1
-F b a k e r.
rv t
V3 GI001
B U
IL
D
IN
G
C O
D E
A N
A
LY
S
IS
KAB
13150149
TGW DAM
V O
LU
M
E
H
A Z
M A
T B
U
IL
D
IN
G
G I0
100% FINAL SUBMITTAL
TOTAL AREA (SQ. FT) 3,920
STORAGE S-1 70,000 70,000 3,195
HIGH HAZARD H-3 14,000 14,000 300
BUSINESS B 92,000
See Note 1
92,000 425
OCCUPANCY TYPE
BASE ALLOWABLE
AREA
(SPRINKLERED,
SINGLE STORY, SQ.
FT)
FRONTAGE
ALLOWANCE
INCREASE (SQ. FT)
TOTAL BUILDING
AREA PERMITTED
(SQ. FT)
ACTUAL FIRST
FLOOR AREA (SQ.
FT)
ALLOWABLE AREA CALCULATIONS FOR CONSTRUCTION TYPE II-B
STORAGE GROUP S-1 (SECTION 311.2) STORAGE (CHAPTER 42)
HIGH HAZARD STORAGE GROUP H-3 (SECTION 307.5) STORAGE (CHAPTER 42)
BUSINESS GROUP B (SECTION 304.1) NEW BUSINESS (CHAPTER 38)
IBC NFPA 101
CLASS A INTERIOR WALL AND CEILING FINISH - FLAME SPREAD INDEX 0-25, SMOKE DEVELOPED INDEX 0-450 CLASS B INTERIOR WALL AND CEILING FINISH - FLAME SPREAD INDEX 26-75, SMOKE DEVELOPED INDEX 0-450 CLASS C INTERIOR WALL AND CEILING FINISH - FLAME SPREAD INDEX 76-200, SMOKE DEVELOPED INDEX 0-450 CLASS I INTERIOR FLOOR FINISH - CRITICAL RADIANT FLUX NOT LESS THAN 0.45 W/(SQ. CM) CLASS II INTERIOR FLOOR FINISH - CRITICAL RADIANT FLUX NOT MORE THAN 0.22 W/(SQ. CM) BUT LESS THAN
0.45 W/(SQ. CM)
CLASS I OR II NO REQUIREMENT N/A
STORAGE
CLASS A OR B CLASS A, B, OR C CLASS A, B, OR C
CLASS I OR II NO REQUIREMENT N/A
NEW BUSINESS
CLASS A OR B CLASS A OR B CLASS A, B, OR C
OCCUPANCY
EXIT ENCLOSURES AND
EXIT PASSAGEWAYS
CORRIDORS
ROOMS AND ENCLOSED
SPACES
INTERIOR FINISH CLASSIFICATION (NFPA 101, TABLE A.10.2.2)
NOTE: ALL HIGH HAZARD STORAGE AREAS MUST COMPLY WITH NFPA 101 SECTION 7.11.4.
HIGH HAZARD STORAGE 0 0 75
ORDINARY HAZARD
STORAGE
100 100 400
NEW BUSINESS 50 100 300
OCCUPANCY DEAD END (FT) COMMON PATH (FT) TRAVEL DISTANCE (FT)
EGRESS LIMITATIONS: SPRINKLERED FACILITY
(NFPA 101 TABLE A.7.6 AND SECTION 7.11)
FIRE BARRIERS 2 90
COMPONENT WALLS AND PARTITIONS (HOUR) FIRE DOOR ASSEMBLIES (MINUTES)
TOTALS: 3,920 13
ELECTRICAL 500 (NET) 110 1
MECHANICAL 500 (NET) 110 1
EXTERIOR ACCESS ONLY: - - -
HIGH HAZARD STORAGE 500 (GROSS) 2,917 6
COMM 500 (GROSS) 80 1
BUSINESS 150 (GROSS) 425 4
USE
OCCUPANT LOAD FACTOR
(SQ. FT/PERSON)
AREA (SQ. FT) OCCUPANT LOAD
P-691 HAZMAT OCCUPANCY LOAD:
UFC 3-600-01 TABLE 10-1 AND NFPA 101 TABLE 7.3.1.2
IRE-2 32 34 170
IRE-1 32 34 170
E-3 32 34 85
E-2 32 34 85
E-1 32 34 170
EXIT NUMBER
MINIMUM REQUIRED CLEAR
WIDTH (INCHES)
ACTUAL CLEAR WIDTH
(INCHES)
CALCULATED OCCUPANT
CAPACITY (PERSONS)
P-691 HAZMAT EXIT CAPACITY CALCULATION
NPFA 101 SECTION 7.2.1.2.3 AND TABLE 7.3.3.1
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
EX.
EX.
EX.
0" D
IP
18" R C P
8"
R C P
8"
R C P
38B
38A
EX. 8
' C
H
AIN
LI
N K F
EN
C E W
/ B
AR
BED
W
IR
E
EX. 6
' P
LA
STIC
F
EN
C E
C O
N C
ASPH
ASPH
GRAVEL
G R A V E L
GRAVEL
M a tta p a n y W a y
T
E
PS
E
T
'-0
33'-0"
164'
185'
80'-1 1/4"
267'
57'-3/4"
SITE LOCATION
1. REFER TO GI001 FOR LIFE SAFETY ANALYSIS.
1. FIRE HYDRANT
2. ATFP SETBACK
3. EXIT DISCHARGE PATHS
4. FIRE DEPARTMENT MAIN ENTRANCE
5. DISTANCE ALONG FIRE DEPARTMENT ACCESS ROAD FOR HYDRANT
SPACING
6. FIRE DEPARTMENT CONNECTION
7. LINE OF ENCROACHMENT
8. BUILDING PERIMETER
9. FIRE DEPARTMENT ACCESS LANE
10. KNOX BOX
11. LOCATION OF TIE-IN POINT TO EXISTING FIRE WATER MAIN. REFER TO
CIVIL DRAWINGS FOR ADDITIONAL INFORMATION.
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S T
E M
S C
O M
M A
N D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D W
A S
H
IN
G T
O N
W A
S H
IN
G
T O
N N
A V
Y Y
A R
D
D .C
AS NOTED
3500 Parkway Lane, Suite 500 Peachtree Corners, GA 30092
W A
S H
IN
G
T O
N D
C C
O R
E
N A
V A
L A
IR
S
T A
T
IO
N P
A T
U X
E N
T R
IV
E
R S
T . M
A R
Y 'S
C O
U N
T Y
, M D
F Y
M
IL
C O
N P
1737036
CONTROLLED UNCLASSIFIED INFORMATION
C O
N T
R O
L L E
D U
N C
L A
S S
IF
IE
D I
N F
O R
M A
T
IO
N
CONTROLLED UNCLASSIFIED INFORMATION
C O
N T
R O
L L E
D U
N C
L A
S S
IF
IE
D I
N F
O R
M A
T
IO
N
PM/CN
TC
SS
04/04/2024
GR
/4
/2
:3
:3
P M
C U s e rs
\d m c c u tc h e o n \D o c u m e n ts
\B L D
G -P
-H
S F
-1
-F b a k e r.
rv t
V3 GI100
LI
F
E S
A F
E T
Y
C O
D E
C O
M P
LI
A
N C
E P
LA
N
KAB
13150150
TGW DAM
V O
LU
M
E
H
A Z
M A
T B
U
IL
D
IN
G
G I1
100% FINAL SUBMITTAL
PLAN
NORTH
GENERAL SHEET NOTES
GRAPHIC SCALE(S)
KEY PLAN
SHEET KEYNOTES#
1" = 30'-0"
LIFE SAFETY - CODE COMPLIANCE PLAN
1" = 30'
0 30' 120'60'
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
FEC
K
F E
C
K
1. REFER TO GI001 FOR LIFE SAFETY ANALYSIS.
LEGEND
DESCRIPTION SYMBOL
FIRE EXTINGUISHER
CABINET
OCCUPANCY
LOAD
EXIT SIGN
TRAVEL
DISTANCE
COMMON PATH
OF TRAVEL
DEAD END
OCCUPANT LOAD
FACTOR
[X/Y]
PERSONS/SQUARE FEET
2 HOUR FIRE
BARRIER
E-X/IRE-X
X
X
X
EXIT COMPONENT
CLEAR WIDTH
CALCULATED CAPACITY
ACTUAL USE
OCCUPANCY
CLASSIFICATION
EXIT LEGEND
2 HR
0'
0'
0'
KNOX BOX
FLAMMABLE
TOXIC
NON-REG WASTE
ADMIN
SHIPPING/ RECEIVING
CORROSIVE ACID
CORROSIVE BASE
UNIVERSAL
NON-REG WASTE
GENERAL STOR
ELEC
MECH
2 HR
H
R
TOILET
G101
COMM
B
S-1
S-1S-1
H
R
2 HR
H
R
2 HR
[ ]1/500
[ ]1/500[ ]1/500
[ ]1/500
65'
39'
H-3
1 2 3 4 5 6
E
D
C
B
A
E-1
E-2
E-3
IRE-1
IRE-2
[ ]1/150
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S T
E M
S C
O M
M A
N D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D W
A S
H
IN
G T
O N
W A
S H
IN
G
T O
N N
A V
Y Y
A R
D
D .C
AS NOTED
3500 Parkway Lane, Suite 500 Peachtree Corners, GA 30092
W A
S H
IN
G
T O
N D
C C
O R
E
N A
V A
L A
IR
S
T A
T
IO
N P
A T
U X
E N
T R
IV
E
R S
T . M
A R
Y 'S
C O
U N
T Y
, M D
F Y
M
IL
C O
N P
1737036
CONTROLLED UNCLASSIFIED INFORMATION
C O
N T
R O
L L E
D U
N C
L A
S S
IF
IE
D I
N F
O R
M A
T
IO
N
CONTROLLED UNCLASSIFIED INFORMATION
C O
N T
R O
L L E
D U
N C
L A
S S
IF
IE
D I
N F
O R
M A
T
IO
N
PM/CN
TC
SS
04/04/2024
GR
/4
/2
:3
:3
P M
C U s e rs
\d m c c u tc h e o n \D o c u m e n ts
\B L D
G -P
-H
S F
-1
-F b a k e r.
rv t
V3 GI101
LI
F
E S
A F
E T
Y
F
IR
S T
F
LO
O R
P
LA
N
KAB
13150151
TGW DAM
V O
LU
M
E
H
A Z
M A
T B
U
IL
D
IN
G
G I1
100% FINAL SUBMITTAL
PLAN
NORTH
GENERAL SHEET NOTES
GRAPHIC SCALE(S)
1/8" = 1' - 0" 0 5' 10' 15' 30'
1/8" = 1'-0"
LIFE SAFETY - FIRST FLOOR PLAN
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
F E
C
K
1 6
E
C
B
A
D
2 3 4 5
TOILET
G101
ADMIN
COMM
MECH
ELEC
GENERAL STOR
FLAMMABLE
TOXIC
NON-REG WASTE
NON-REG WASTE
UNIVERSAL
CORROSIVE BASE
CORROSIVE ACID
SHIPPING/ RECEIVING
1 2 3 4
STEEL SLEEVE CAST IN
PLACE;
EXTEND SLEEVE MINIMUM 1"
ABOVE FLOOR
FILL GAP COMPLETELY
AROUND PIPE WITH FIRE CAULK
AS REQUIRED; USE FILLER ROD
PER MANUFACTURER AND FILL
FLUSH TO TOP OF PIPE SLEEVE
4" SCH. 40 PVC TEE LOCATED
IN GRAVEL BED
NONCOMPACTED GRAVEL BED
MIN. 4"
FINISHED FLOOR
12" TURBINE VENTILATOR WITH
CUSTOM COLOR FINISH - COLOR
TO MATCH ROOF, 4" Ø THROAT.
147 CFM @ 4 MPH WIND
METAL PIPE STRAPATTACH TURBINE VENTILATOR TO
TOP OF 4" VENT THROUGH ROOF.
LOCATE ABOVE PIPE FLASHING
COLLAR.
REFER TO ARCHITECTURAL
DRAWINGS FOR ROOF PIPE
VENT DETAILS
MIN. 12"
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S T
E M
S C
O M
M A
N D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D W
A S
H
IN
G T
O N
W A
S H
IN
G
T O
N N
A V
Y Y
A R
D
D .C
AS NOTED
3500 Parkway Lane, Suite 500 Peachtree Corners, GA 30092
GRAPHIC SCALE(S)
W A
S H
IN
G
T O
N D
C C
O R
E
N A
V A
L A
IR
S
T A
T
IO
N P
A T
U X
E N
T R
IV
E
R S
T . M
A R
Y 'S
C O
U N
T Y
, M D
F Y
M
IL
C O
N P
1737036
CONTROLLED UNCLASSIFIED INFORMATION
C O
N T
R O
L L E
D U
N C
L A
S S
IF
IE
D I
N F
O R
M A
T
IO
N
CONTROLLED UNCLASSIFIED INFORMATION
C O
N T
R O
L L E
D U
N C
L A
S S
IF
IE
D I
N F
O R
M A
T
IO
N
PM/CN
TC
SS
04/04/2024
GR
/8
/2
:1
:0
A M
C U s e rs
\R y a n .B ro w n \O n e D ri v e
M ic h a e l B a k e r In te rn a ti o n a l\ D e s k to p \R e v it L o c a l\ B
L D
G -P
-H
S F
-1
-P
R y a n .B ro w n X
Z W
B
.r v t
V3 H-111
H A
Z A
R D
O U
S
P
LA
N
SH
13150152
SRR SAK
V O
LU
M
E
H
A Z
M A
T B
U
IL
D
IN
G
H -1
100% FINAL SUBMITTAL
SCALE: 1/8" = 1'-0"
HAZARDOUS - 1ST FLOOR PLAN
A3
KEYNOTES
1 4" VENT RISER UP FROM BELOW SLAB.
2 ROUTE 4" VENT RISER UP THROUGH THE ROOF TO THE OUTSIDE.
TERMINATE RISER MINIMUM 12" ABOVE THE ROOF AND AT LEAST 10'-0" FROM
ANY OPERABLE OPENING OR AIR INTAKE. PROVIDE VENT TERMINATION WITH
12" TURBINE VENTILATOR. SEAL OPENINGS BETWEEN THE PIPING AND
FLOOR SLABS. PROVIDE ALL MOUNTING AND ELECTRICAL REQUIREMENTS
FOR FUTURE FAN.
3 LOCATION FOR THE FUTURE RADON MITIGATION SYSTEM FAN MUST BE
UNDER THE ROOF DECK AND SECURED IN A MANNER THAT MINIMIZES
TRANSFER OF VIBRATION TO THE STRUCTURAL FRAMING. FLEXIBLE
CONNECTORS MUST BE PROVIDED AT BOTH ENDS OF THE FAN. WIRE
REQUIREMENTS MUST CONFORM WITH THE OTHER PROVISIONS OF THE
NATIONAL ELECTRIC CODE AND OTHER LOCAL REGULATIONS.
4 MAINTAIN MINIMUM 1/8" PER 1'-0" SLOPE. COORDINATE ROUTING WITH
OTHER DISCIPLINES ABOVE THE CEILING.
SCALE:
4' 8' 16'0
1/8" = 1'-0"
PLAN
NORTH
GENERAL NOTES
1 PIPING LAYOUT AND DETAILS SHOWN TO PROVIDE GENERAL
REQUIREMENTS OF THE RADON MITIGATION SYSTEM.
2 PROVIDE VERTICAL RISER VENTILATION PIPING FOR A PASSIVE AIR RADON
MITIGATION SYSTEM.
3 PROVISIONS MUST BE PROVIDED TO CONVERT THE SYSTEM TO AN ACTIVE
SYSTEM.
4 AT THE COMPLETION OF CONSTRUCTION AND PRIOR TO OCCUPANCY THE
CONTRACTOR MUST PERFORM TESTING BY AN APPROVED INDEPENDANT
TESTING AGENCY FOR PROPER FUNCTIONALITY. INCLUDING A SMOKE TEST
AND A PRESSURE READING TEST THROUGH THE RISER PIPES.
5 ALL COMPONENTS OF THE RADON MITIGATION SYSTEM MUST BE IN
COMPLIANCE WITH THE APPLICABLE MECHANICAL, ELECTRICAL, BUILDING,
PLUMBING, ENERGY AND FIRE PREVENTION CODES AS WELL AS ALL LOCAL
CODES, STANDARDS AND REGULATIONS.
6 A MINIMUM 4-INCH THICK AASHTO #57 STONE SLAB BASE COURSE MUST BE
PROVIDED. ALL PENTRATIONS MUST BE SEALED TO CREATE A MONOLITHIC
MEMEBRANE BETWEEN THE SURFACE OF THE SLAB AND MOISTURE
SOURCES BELOW THE SLAB AND AT THE SLAB PERIMIETER. REFER TO
STRUCTURAL DRAWINGS FOR ADDITIONAL DETAILS.
7 ALL RADON MITIGATION SYSTEM PIPING IS TO BE SCHEDULE 40 PVC OR
EQUIVALENT PIPING MATERIAL. ALL JOINTS AND CONNECTIONS IN THE
SYSTEM MUST BE PERMANENTLY SEALED AIR TIGHT WITH ADHESIVES AS
SPECIFICED BY THE MANUFACTURER OF THE PIPE MATERIAL UTILIZED.
8 LABEL THE EXPOSED RADON MITIGATION SYSTEM PIPING TO IDENTIFY THE
PIPE AS A COMPONENT OF THE RADON MITIGATION SYSTEM. LABELS MUST
BE PLACED AT LEAST EVERY 10 FT ALONG PIPE RUNS.
9 ALL PIPING SHALL BE SUPPORTED AT LEAST EVERY 6 FEET ON HORIZONTAL
RUNS. VERTICAL RUNS SHALL BE SECURED EITHER BELOW OR ABOVE THE
POINT OF PENETRATION AND AT LEAST EVERY 8 FEET. ALL SUPPORTS MUST
ONLY BE FASTENED TO THE STRUCTURE OF THE BUILDING.
SCALE:NTS
RADON MITIGATION VENT PIPE DETAIL - THROUGH FLOOR
C3
SCALE:NTS
RADON MITIGATION VENT PIPE DETAIL - THROUGH ROOF
A1
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R t
DAVID W HUFO
I
II
}i f,rolmt0 PROFf t t{ ll] Pt;61t69
04 APRIL 2o24
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S T
E M
S C
O M
M A
N D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D W
A S
H
IN
G T
O N
W A
S H
IN
G
T O
N N
A V
Y Y
A R
D
D .C
AS NOTED
3500 Parkway Lane, Suite 500 Peachtree Corners, GA 30092
W A
S H
IN
G
T O
N D
C C
O R
E
N A
V A
L A
IR
S
T A
T
IO
N P
A T
U X
E N
T R
IV
E
R S
T . M
A R
Y 'S
C O
U N
T Y
, M D
F Y
M
IL
C O
N P
1737036
CONTROLLED UNCLASSIFIED INFORMATION
C O
N T
R O
L L E
D U
N C
L A
S S
IF
IE
D I N
F O
R M
A T
IO
N
CONTROLLED UNCLASSIFIED INFORMATION
C O
N T
R O
L L E
D U
N C
L A
S S
IF
IE
D I N
F O
R M
A T
IO
N
PM/CN
TC
SS
04/04/2024
GR
/3
/2
:2
:1
P M
C U s e rs
\j a m e s .c u m m in g s \D o c u m e n ts \B
L D
G -P
-H S
F -1
-S
J a m e s .C u m m in g s B
B Z
R A
.r v t
V3 S-001
D E
S
IG
N C
R
IT
E R
IA
A
N D
G E
N E
R A
L N
O
TE
S
DRB
13150153
JDZ JAC
V O
LU
M
E
H
A Z
M A
T B
LD
G
S -0
100% FINAL SUBMITTAL
DESIGN CRITERIA
DC-1 BUILDING CODE: INTERNATIONAL BUILDING CODE (IBC) 2021,
AS AMENDED BY UFC 1-200-01 AND UFC 3-301-01
DC-2 LATERAL LOAD DESIGN CRITERIA
A. RISK CATEGORY IV
B. WIND DESIGN CRITERIA
1. BASIC DESIGN WIND SPEED (V) 128 MPH
2. ALLOWABLE DESIGN WIND SPEED (Vasd) 99 MPH
3. EXPOSURE CATEGORY C
4. INTERNAL PRESSURE COEFFICIENT +/- 0.18
C. SEISMIC DESIGN CRITERIA
1. SEISMIC IMPORTANCE FACTOR (Ie) 1.5
2. SITE CLASS D
3. SHORT PERIOD SPECTRAL ACCELERATION (SS) 0.114g
4. ONE SECOND SPECTRAL ACCELERATION (S1) 0.041g
5. SHORT PERIOD RESPONSE ACCELERATION (SDS) 0.122g
6. ONE SECOND RESPONSE ACCELERATION (SD1) 0.066g
7. SEISMIC DESIGN CATEGORY A
8. SEISMIC RESPONSE COEFFICIENT (CS) 0.06
9. SEISMIC DESIGN BASE SHEAR PER MFR
10. SEISMIC RESISTING SYSTEM:
STRUCTURAL STEEL SYSTEMS NOT SPECIFICALLY DETAILED FOR
SEISMIC RESISTANCE (R =3.0)
11. ANALYSIS METHOD: EQUIVALENT LATERAL FORCE PROCEDURE
DC-3 GRAVITY LOADS
A. DEAD LOADS
1. BUILDING SELF WEIGHT + 5 PSF COLLATERAL
A. MINIMUM (FOR UPLIFT) 3 PSF
B. LIVE LOADS
1. ROOF 20 PSF MIN
2. TYPICAL (STORAGE) 250 PSF
3. MECHANICAL/ELECTRICAL/TELECOM 150 PSF
C. VEHICLE LOADS
1. UFC FORKLIFT CATEGORY II 15 KIP MAX AXLE LOAD
D. SNOW LOADS
1. GROUND SNOW LOAD (Pg) 20 PSF
2. MINIMUM SNOW LOAD (Pm) 24 PSF
3. FLAT-ROOF SNOW LOAD(Pf) 18.5 PSF
4. SLOPED ROOF SNOW LOAD (Ps) 18.5 PSF
5. SNOW IMPORTANCE FACTOR (Is) 1.2
6. SNOW EXPOSURE FACTOR (Ce) 1.0
7. THERMAL FACTOR (Ct) 1.1
8. ADD'L UNBALANCED SNOW LOAD AS PER APPLICABLE BLDG CODE
E. CONSTRUCTION LOADS
1. NOT TO EXCEED THE DESIGN LIVE LOADS.
DC-4 FOUNDATION DESIGN CRITERIA
A. FOUNDATION DESIGN IS BASED UPON THE FOLLOWING SOIL
PARAMETERS:
1. NET ALLOWABLE SOIL BEARING PRESSURE:
A. SPREAD FOOTINGS: 2000 PSF
B. CONTINUOUS FOOTINGS: 2000 PSF
B. ASSUMED LATERAL EARTH PRESSURE PARAMETERS:
1. SOIL DENSITY = 100 PCF
2. COEFFICIENT OF ACTIVE PRESSURE (Ka) = 0.45
3. COEFFICIENT OF AT-REST PRESSURE (Ko) = 0.60
4. COEFFICIENT OF PASSIVE EARTH PRESSURE (Kp) = 3.00
5. ANGLE OF INTERNAL FRICTION (phi) = 28 DEGREES
6. COEFFICIENT OF FRICTION (u) = 0.35
7. MODULUS OF SUB-GRADE REACTION (ks) = 100 PCI
C. FROST DEPTH: 26 INCHES
D. MINIMUM BEARING DEPTH: 26 INCHES
DC-5 ANTI-TERRORISM CRITERIA
A. THIS FACILITY HAS BEEN DESIGNED IN ACCORDANCE WITH THE ANTI-
TERRORISM (AT) REQUIREMENTS SET FORTH IN UFC 4-010-01, DATED
30 JULY 2022. BUILDING ANTI-TERRORISM DESIGN CRITERIA ARE AS
FOLLOWS:
B. AT FACILITY CRITERIA
1. BUILDING SITE LOCATION WITHIN INSTALLATION PERIMETER
2. BUILDING CATEGORY UNINHABITED
3. BUILDING STANDOFF DISTANCE > 50 FT TO PERIMETER
4. UNOBSTRUCTED SPACE 33 FT
5. PROGRESSIVE COLLAPSE N/A
6. STRUCTURAL ISOLATION N/A
GENERAL
G-1 METHODS, PROCEDURES AND SEQUENCES OF CONSTRUCTION ARE
THE RESPONSIBILITY OF THE CONTRACTOR. THE CONTRACTOR IS
RESPONSIBLE FOR IDENTIFYING AND IMPLEMENTING THE
NECESSARY PRECAUTIONS TO MAINTAIN AND ENSURE THE
INTEGRITY OF THE STRUCTURE AT EACH STAGE OF CONSTRUCTION.
G-2 TEMPORARY BRACING, SHEETING, SHORING, ETC, REQUIRED TO
ENSURE THE STRUCTURAL INTEGRITY/STABILITY OF THE EXISTING
BUILDINGS, SIDEWALKS, UTILITIES, ETC, DURING CONSTRUCTION IS
THE RESPONSIBILITY OF THE CONTRACTOR AND MUST BE DESIGNED
BY A REGISTERED PROFESSIONAL ENGINEER EMPLOYED BY THE
CONTRACTOR.
G-3 IMPLEMENTATION OF JOB SITE SAFETY IS THE SOLE RESPONSIBILITY
OF THE CONTRACTOR.
G-4 WHEN NOT SPECIFICALLY INDICATED ON THE STRUCTURAL
DRAWINGS, THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING
SLEEVE AND BLOCK-OUT REQUIREMENTS FOR PENETRATIONS PRIOR
TO FABRICATION OR ERECTION OF THE STRUCTURE. PENETRATIONS
OF STRUCTURAL MEMBERS ARE SUBJECT TO APPROVAL BY THE
CONTRACTING OFFICER. THE CONTRACTOR IS ALSO RESPONSIBLE
FOR DETERMINING ANCHORAGE AND HANGER REQUIREMENTS
REQUIRED FOR SUPPORTING EQUIPMENT, FINISHES, UTILITIES
ETCETERA NOT INDICATED ON THE STRUCTURAL DRAWINGS.
G-5 DO NOT SCALE DRAWINGS.
G-6 THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING AND
COORDINATING DIMENSIONS AND INSTALLATION DETAILS OF
PURCHASED EQUIPMENT WITH THE SUPPORTING
STRUCTURE. CONFLICTS BETWEEN THESE ITEMS AND THE BUILDING
STRUCTURE MUST BE BROUGHT TO THE ATTENTION OF THE
CONTRACTING OFFICER FOR RESOLUTION.
G-7 THE STRUCTURAL DRAWINGS GOVERN THE WORK FOR STRUCTURAL
FEATURES, UNLESS OTHERWISE NOTED. DIMENSIONS SHOWN ON
PLANS AND DETAILS ARE TO GOVERN THE STRUCTURAL WORK. THE
CONTRACTOR IS TO REFER TO THE ARCHITECTURAL DRAWINGS FOR
DIMENSIONS AND DETAILS NOT PROVIDED. DIMENSIONAL CONFLICTS
IN THE DOCUMENTS MUST BE BROUGHT TO THE ATTENTION OF THE
CONTRACTING OFFICER.
G-8 IN CASE OF CONFLICT BETWEEN THE GENERAL NOTES,
SPECIFICATIONS, DRAWINGS, OR WITHIN THESE DOCUMENTS, THE
MOST STRINGENT REQUIREMENTS AS DETERMINED BY THE
CONTRACTING OFFICER WILL GOVERN.
G-9 WORK NOT INDICATED ON A PART OF THE DRAWINGS, BUT
REASONABLY IMPLIED TO BE SIMILAR TO THAT SHOWN AT
CORRESPONDING LOCATIONS, IS TO BE REPEATED.
FOUNDATIONS
F-1 FOUNDATIONS HAVE BEEN DESIGNED IN ACCORDANCE WITH
CRITERIA ESTABLISHED BY TERRACON IN THEIR GEOTECHNICAL
REPORT PREPARED FOR THIS PROJECT DATED FEBRUARY 5, 2024.
F-2 FOUNDATIONS MUST BE PLACED ON COMPACTED SOIL MEETING THE
REQUIREMENTS OF STRUCTURAL FILL OR ON LEAN CONCRETE
BACKFILL.
F-3 THE CONTRACTOR IS TO RETAIN THE SERVICES OF A PROFESSIONAL
GEOTECHNICAL ENGINEER, SUBJECT TO THE APPROVAL OF THE
OWNER, TO VERIFY THAT THE MATERIAL ON WHICH FOUNDATIONS
BEAR HAS AT LEAST THE CAPACITY AS NOTED IN THE DESIGN
CRITERIA. THE GEOTECHNICAL ENGINEER IS TO MAKE
RECOMMENDATIONS FOR IMPROVING AREAS THAT DO NOT MEET
THE DESIGN CRITERIA.
F-4 EXTERIOR FOOTINGS ARE TO BEAR A MINIMUM OF 26 INCHES BELOW
FINISHED GRADE. ELEVATIONS SHOWN ON THE DRAWINGS AT WHICH
FOUNDATIONS BEAR ARE APPROXIMATE AND MAY VARY TO SUIT
SUBSURFACE SOIL CONDITIONS. STEP-IN FOOTING LOCATIONS
SHOWN ON THE DRAWINGS MUST BE FIELD VERIFIED AND ADJUSTED
SO THAT FOUNDATIONS BEAR ON MATERIAL OF AT LEAST THE
CAPACITY NOTED ABOVE.
F-5 PRIOR TO PLACING CONCRETE, WATER PRESENT MUST BE PUMPED
OUT FROM THE BOTTOM OF EXCAVATIONS.
F-6 CONCRETE SLABS-ON-GRADE HAVE BEEN DESIGNED TO BEAR ON
COMPACTED SUB-GRADE SOILS. THE DRAINAGE BASE COURSE
MATERIAL BENEATH THE SLAB-ON-GRADE IS TO BE FREE-DRAINING
(LESS THAN 5% PASSING THE US NO. 200 SIEVE) AND BE COMPACTED
TO AT LEAST 95% OF ASTM D 1557.
F-7 NO BACKFILLING AGAINST WALLS IS ALLOWED UNTIL THE SLABS AT
THE TOP AND BOTTOM HAVE BEEN PLACED OR ADEQUATE SHORING
HAS BEEN PROVIDED. WALLS AND GRADE BEAMS HAVING BACKFILL
AGAINST BOTH SIDES ARE TO HAVE BACKFILL PLACED ON BOTH
SIDES UNIFORMLY SO AS NOT TO EXCEED AN 8” DIFFERENTIAL.
F-8 EQUIPMENT AND/OR MATERIALS WITH WEIGHT GREATER THAN THE
DESIGN SURCHARGE MUST MAINTAIN A SAFE HORIZONTAL CLEAR
DISTANCE FROM BASEMENT AND RETAINING WALLS. A SAFE
HORIZONTAL CLEAR DISTANCE IS DEFINED AS THE DISTANCE FROM
THE BASE OF THE RETAINING WALL TO THE TOP OF FINISHED GRADE.
DESIGN SURCHARGE EQUALS 100 PSF.
F-9 THE FOUNDATION SYSTEM HAS BEEN DESIGNED TO SUPPORT A PRE-
ENGINEERED BUILDING BASED UPON A DESIGN ANALYSIS
PERFORMED BY THE STRUCTURAL ENGINEER. THE FOLLOWING
CONCRETE REQUIREMENTS FOR PRE-ENGINEERED BUILDING APPLY:
A. THE FOUNDATION MUST BE SQUARE AND LEVEL. OUT OF LEVEL
TOLERANCE FOR TOP OF CONCRETE PIERS AND WALLS IS +/-1/8"
IN 20'-0" AND +/-1/4" IN OVERALL LENGTH. TOLERANCE BETWEEN
CENTERLINES OF COLUMN ANCHOR BOLT CLUSTERS IS +/-1/8" IN
20'-0" AND +/-1/4" OVERALL.
B. ADJUST THE ELEVATION OF THE TOP OF PIERS IN ACCORDANCE
WITH BUILDING MANUFACTURER'S STANDARD. TROWEL FINISH
TOP OF CONCRETE AT COLUMN BASES.
C. ADJUST DIMENSIONS OF CONCRETE PIERS GIVEN TO PROVIDE A
MINIMUM OF 2" BEYOND EACH SIDE OF THE COLUMN BASE PLATE.
NOTE: PIER SIZE GIVEN IS MINIMUM, REVISIONS TO PIER SIZES
SHOWN ON THE DRAWINGS MUST BE PROVIDED TO THE
ENGINEER FOR REVIEW.
D. ANCHOR RODS MUST BE SET BY MEANS OF A TEMPLATE. (DO
NOT HAND SET)
E. MISCELLANEOUS JAMB POSTS MUST BE ANCHORED TO
FOUNDATION BY MEANS OF POST-INSTALLED ANCHORS AS PER
BUILDING MANUFACTURER'S DRAWINGS.
REINFORCED CONCRETE
C-1 REINFORCED CONCRETE WORK MUST BE IN ACCORDANCE WITH THE
AMERICAN CONCRETE INSTITUTE (ACI) "BUILDING CODE
REQUIREMENTS FOR STRUCTURAL CONCRETE - ACI 318" (LATEST
EDITION) AND THE “SPECIFICATIONS FOR STRUCTURAL CONCRETE
FOR BUILDINGS- ACI 301” (LATEST EDITION).
C-2 PRIOR TO CONCRETE PLACEMENT, THE CONTRACTOR MUST SUBMIT
CONCRETE MIX DESIGNS FOR EACH TYPE OF CONCRETE TO BE
USED, PREPARED IN ACCORDANCE WITH THE PROJECT
SPECIFICATIONS, TO THE CONTRACTING OFFICER FOR REVIEW.
C-3 CAST-IN-PLACE CONCRETE MUST HAVE A MINIMUM 28 DAY
COMPRESSIVE STRENGTH (f'c) AS INDICATED ON THE CONCRETE
MATERIALS SCHEDULE ON DRAWING S-601.
C-4 REINFORCEMENT:
A. DEFORMED BARS: ASTM A 615/A 615M, GRADE 60
B. WELDED WIRE REINFORCEMENT: ASTM A 1064
C-5 SPLICES (LAPS) OF REINFORCING BARS MUST BE CLASS ‘B’ TENSION
LAPS PER ACI 318 (LATEST EDITION) UNLESS NOTED OTHERWISE.
REFER TO THE MINIMUM LAP SPLICES OF REINFORCING BARS IN
TENSION SCHEDULE ON DRAWING S-601.
C-6 PROVIDE ADEQUATE CONCRETE COVER IN ACCORDANCE WITH THE
REQUIREMENTS AS SET FORTH BY ACI 318. REFER TO THE
CONCRETE COVER SCHEDULE ON DRAWING S-601.
C-7 CONTINUOUS REINFORCING BARS MUST BE TURNED AND LAPPED AT
CORNERS AND INTERSECTIONS OF WALLS AND FOOTINGS. HOOKED
BARS TO HAVE STANDARD ACI HOOKS UNLESS NOTED OTHERWISE.
C-8 CONTINUOUS TOP BARS MUST BE SPLICED AT MID-SPAN.
CONTINUOUS BOTTOM BARS MUST BE SPLICED AT CENTERLINE OF
SUPPORTS (OR AS SHOWN ON DETAILS).
C-9 WELDED WIRE REINFORCEMENT MUST BE SUPPLIED IN FLAT SHEETS
ONLY. LAP WELDED WIRE REINFORCEMENT TWO FULL MESH
LENGTHS AT SPLICES AND WIRE TOGETHER. PLACE WELDED WIRE
REINFORCEMENT WITHIN THE SLAB THICKNESS PER THE TYPICAL
DETAILS.
C-10 CONCRETE SLABS MUST BE CURED BY METHOD COMPATIBLE WITH
SPECIFIED FLOOR FINISH. WHERE ACCEPTABLE USE A LIQUID
MEMBRANE-CURING COMPOUND AT THE MANUFACTURERS
RECOMMENDED COVERAGE.
C-11 SLOPE SLABS-ON-GRADE TO DRAIN. MAINTAIN MINIMUM DESIGN
THICKNESS INDICATED.
C-12 DIVIDE FLOOR SLABS-ON-GRADE INTO SEGMENTS BY MEANS OF
ISOLATION, CONTROL AND CONSTRUCTION JOINTS AS INDICATED ON
THE DRAWINGS. SAW JOINTS MUST BE CUT AS SOON AS POSSIBLE
WITHOUT RAVELING THE SURFACE. POSITION OF CONSTRUCTION
JOINTS OTHER THAN THOSE SHOWN ON THE DRAWINGS MUST BE
SUBMITTED TO THE CONTRACTING OFFICER FOR APPROVAL.
C-13 SLAB-ON-GRADE CONTROL JOINTS MUST BE PLACED ON COLUMN
CENTERLINES UNO. CONTROL JOINTS MUST BE PLACED AT EQUAL
INTERVALS IN EACH DIRECTION AS INDICATED ON THE PLANS. ADAPT
CONTROL JOINT LOCATION AT ODD BAYS. CONSTRUCTION JOINTS
MUST BE PLACED AT CONTROL JOINT LOCATIONS AT CONTRACTOR’S
DISCRETION UNO ON PLAN.
C-14 SLEEVES, INSERTS, MECHANICAL OPENINGS, CONDUITS, PIPES,
RECESSES, DEPRESSIONS, CURBS AND OTHER EMBEDDED ITEMS
MUST BE PROVIDED AS SHOWN ON THE ARCHITECTURAL,
MECHANICAL, FIRE PROTECTION, PLUMBING AND ELECTRICAL
DRAWINGS AND BY EQUIPMENT MANUFACTURERS. INSTALLATION OF
THESE ITEMS MUST BE COORDINATED AND PROVIDED FOR PRIOR TO
PLACING CONCRETE.
C-15 OPENINGS IN CONCRETE SLABS AND/OR CONCRETE WALLS MUST
HAVE ADDITIONAL REINFORCEMENT PER THE TYPICAL DETAILS. NO
PENETRATIONS ARE PERMITTED THROUGH ANY CONCRETE
BEAM, JOIST, COLUMN, PIER OR JAMB WITHOUT THE ENGINEER’S
WRITTEN APPROVAL. PENETRATIONS MUST BE RE-ROUTED AS
REQUIRED AT THESE LOCATIONS.
C-16 PENETRATIONS THROUGH CONCRETE SLABS AND/OR CONCRETE
WALLS MUST BE PLACED DURING CONSTRUCTION OF THE WALL WITH
THE APPROPRIATE SLEEVE.
C-17 ANCHOR RODS TO BE ASTM F 1554 Fy = 36 KSI MINIMUM, UNLESS
NOTED OTHERWISE. DIAMETER AND LOCATIONS MUST BE AS
INDICATED ON THE PRE-ENGINEERED METAL BUILDING DRAWINGS
(BY OTHERS). ANCHOR ROD EMBEDMENT MUST BE AS INDICATED ON
THESE STRUCTURAL DRAWINGS.
C-18 WATERSTOPS AT THE CONTAINMENT AREA TO BE CHEMICAL
RESISTANT. WATERSTOPS ARE TO BE 6" MIN, RIBBED WITH A
CENTERBULB SIZED FOR 1/4" MOVEMENT IN ANY DIRECTION.
MASONRY
M-1 MASONRY WORK MUST BE IN CONFORMANCE WITH THE AMERICAN
CONCRETE INSTITUTE (ACI) "BUILDING CODE FOR MASONRY
STRUCTURES-ACI 530” (LATEST EDITION) AND THE “SPECIFICATIONS
FOR MASONRY STRUCTURES-ACI 530.1” (LATEST EDITION).
M-2 CONCRETE MASONRY TO HAVE A MINIMUM 28 DAY COMPRESSIVE
STRENGTH OF MASONRY (f'm) OF 2,000 PSI AND:
A. HOLLOW BLOCK: ASTM C 90, NORMAL WT.
B. SOLID BLOCKS: ASTM C 90.
M-3 DEFORMED BAR REINFORCEMENT PER ASTM A 615/A 615M GRADE 60.
A. PROVIDE MINIMUM LAP SPLICES OF 48 BAR DIAMETERS.
B. PROVIDE BAR SPACERS TO LOCATE REINFORCING WITHIN CMU
CELLS.
M-4 HORIZONTAL JOINT REINFORCING TO BE SPACED AT 16" OC IN WALLS
UNO AND MUST BE GALVANIZED, STANDARD CLASS, LADDER TYPE,
CONFORMING TO ASTM A951. SIDE RODS TO BE 3/16" WITH NO. 9
CROSS RODS UNO. PROVIDE ONE-PIECE PREFABRICATED
REINFORCING UNITS AT 8” OC AT WALL CORNERS AND
INTERSECTIONS AND IN THE FIRST TWO COURSES ABOVE AND
BELOW MASONRY OPENINGS. PROVIDE LAP AS RECOMMENDED BY
THE MANUFACTURER WITH A MINIMUM OF 6". DISCONTINUE
HORIZONTAL JOINT REINFORCING AT CONTROL JOINTS.
M-5 BOND BEAMS AND REINFORCING TO BE DISCONTINUOUS AT
CONTROL JOINTS UNLESS NOTED OTHERWISE. BOND BEAM
REINFORCING AT THE TOP OF WALLS IS TO BE CONTINUOUS.
M-6 CONTROL JOINT SPACING IN MASONRY WALLS MUST BE PROVIDED
WHERE INDICATED ON THE STRUCTURAL DRAWINGS, OR A MAXIMUM
OF 24'-0" ON CENTER.
M-7 FULL HEIGHT MASONRY WALLS TO BE TEMPORARILY BRACED UNTIL
FLOOR OR ROOF SYSTEM HAS BEEN INSTALLED AND HAS BECOME
CAPABLE OF STABILIZING THE WALLS.
M-8 DOWEL REINFORCED MASONRY WALLS TO FOUNDATION. SIZE
DOWELS TO MATCH WALL REINFORCEMENT. LOCATE DOWELS IN
CELLS TO CONTAIN WALL REINFORCEMENT. LAP DOWELS WITH
WALL REINFORCEMENT A MINIMUM OF 48 BAR DIAMETERS UNO.
M-9 UNLESS NOTED OTHERWISE, PLACE TYPICAL CMU REINFORCEMENT
IN CENTER OF FULLY GROUTED CELLS AND SPACE AS FOLLOWS:
A. FOR 8” CMU: (1) #5 VERTICAL AT 32” ON CENTER.
B. PROVIDE ADDITIONAL BARS AT CORNERS AND OPENINGS PER
TYPICAL DETAILS.
M-10 CORNERS AND INTERSECTIONS TO BE TIED BY MASONRY BOND.
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P
04/04/2024
ABBREVIATIONS
RO ROUGH OPENING
RTU ROOF TOP UNIT
S SOUTH
SC SLIP CRITICAL
SCHED SCHEDULE
SDI STEEL DECK INSTITUTE
SECT SECTION
SF SQUARE FOOT
SHT SHEET
SIM SIMILAR
SL SLOPE, SLOPED OR SLOPING
SLV SLEEVE
SOG SLAB ON GRADE
SP SPACE, SPACES OR SPACING
SPEC SPECIFY, SPECIFIED OR SPECIFICATIONS
SQ SQUARE
SQ FT SQUARE FOOT
SS STAINLESS STEEL
STD STANDARD
STIFF STIFFENER
STL STEEL
STRUCT STRUCTURAL
SUSP SUSPEND, SUSPENDED OR SUSPENSION
T&B TOP & BOTTOM
T/ TOP OF
T/C TOP OF CURB
TEMP TEMPORARY
TERM TERMINATE OR TERMINAL
THD THREAD OR THREADED
THK THICK OR THICKNESS
THRESH THRESHOLD
TPV THERMOPLASTIC VULCANIZATE
TRANS TRANSVERSE
TRTD TREATED
TSF TONS PER SQUARE FEET
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
VERT VERTICAL
VIF VERIFY IN FIELD
W WEST
WDH WIDTH
W/ WITH
W/O WITHOUT
WL WIND LOAD
WP WORKING POINT
WT WEIGHT
WWR WELDED WIRE REINFORCEMENT
A/E ARCHITECT/ENGINEER
AB ANCHOR BOLT
ABV ABOVE
ACI AMERICAN CONCRETE INSTITUTE
ADDL ADDITIONAL
ADJ ADJACENT
ADJBL ADJUSTABLE
AFF ABOVE FINISHED FLOOR
AHU AIR HANDLING UNIT
AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION
ALT ALTERNATE
APPROX APPROXIMATE OR APPROXIMATELY
ARCH ARCHITECT OR ARCHITECTURAL
ASTM AMERICAN SOCIETY FOR TESTING MATERIAL
AVG AVERAGE
B PL BASE PLATE OR BEARING PLATE
B/ BOTTOM OF
B/C BOTTOM OF CURB
BD BOARD
BF BOTH FACES
BFF BELOW FINISHED FLOOR
BIT BITUMINOUS
BLDG BUILDING
BLK BLOCK
BLKG BLOCKING
BLW BELOW
BMK BENCH MARK
BM BEAM
BOT BOTTOM
BR BRICK
BRG BEARING
BRKT BRACKET
BS BOTH SIDES
BSMT BASEMENT
BT BENT
BTWN BETWEEN
CB CATCH BASIN
CC CENTER TO CENTER
CEM PL CEMENT PLASTER
CF CUBIC FOOT OR CUBIC FEET
CHAM CHAMFER
CIP CAST IN PLACE
CJ CONTROL JOINT
CL CENTERLINE
CLR CLEAR
CMU CONCRETE MASONRY UNIT
CO CLEAN OUT
COL COLUMN
CONC CONCRETE
CONN CONNECTION
CONST CONSTRUCTION
CONT CONTINUOUS
CONTR CONTRACTOR
COOR COORDINATE
CORR CORRIDOR
CRSE COURSE
CRSI CONCRETE REINFORCING STEEL INSTITUTE
CY CUBIC YARD
db BAR DIAMETER
DBL DOUBLE
DIA DIAMETER
DIAG DIAGONAL
DIM DIMENSION
DL DEAD LOAD
DN DOWN
DTL DETAIL
DWG DRAWING
DWL DOWEL
E EAST
EA EACH
EF EACH FACE
EIFS EXTERIOR INSULATION FINISH SYSTEM
EJ EXPANSION JOINT
ELE ELEVATOR
ELEC ELECTRICAL
ELEV ELEVATION
EMBED EMBED, EMBEDED OR EMBEDMENT
ENCL ENCLOSE OR ENCLOSURE
ENGR ENGINEER
EOS EDGE OF SLAB
EQ EQUAL
EQUIP EQUIPMENT
EST ESTIMATE OR ESTIMATED
EW EACH WAY
EXC EXCAVATE OR EXCAVATION
EXCL EXCLUDE OR EXCLUDING
EXIST EXISTING
EXP EXPANSION
EXP BLT EXPANSION BOLT
EXT EXTERIOR
F/F FACE TO FACE
FD FLOOR DRAIN
FDN FOUNDATION
FF FAR FACE
FIN FINISH OR FINISHED
FL FLOOR
FPRF FIREPROOF OR FIREPROOFING
FS FAR SIDE
FT FOOT OR FEET
FTG FOOTING
GA GAUGE/GAGE
GALV GALVANIZED
GB GRADE BEAM
GC GENERAL CONTRACTOR
GD GRADE(ING)
GRAV GRAVEL
GRD GROUND
GRT GROUT
HM HOLLOW METAL
HORIZ HORIZONTAL
HP HIGH POINT
HT HEIGHT
ID INSIDE DIAMETER
IN INCH(ES)
INCL INCLUDE
INFO INFORMATION
INT INTERIOR
ISO JT ISOLATION JOINT
JB JAMB
JST JOIST
JT JOINT
K KIP(S)
KB KNEE BRACE
KCF KIPS PER CUBIC FEET
KLF KIPS PER LINEAR FOOT
KSF KIPS PER SQUARE FEET
KSI KIPS PER SQUARE INCH
L LENGTH
LB POUND
ld DEVELOPMENT LENGTH
LF LINEAR FOOT
LG LONG
LL LIVE LOAD
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LONG LONGITUDINAL
LP LOW POINT
LTL LINTEL
MEP MECHANICAL, ELECTRICAL & PLUMBING
MAS MASONRY
MATL MATERIAL
MAX MAXIMUM
MCJ MASONRY CONTROL JOINT
MECH MECHANICAL
MEMB MEMBRANE
MEZZ MEZZANINE
MFR MANUFACTURE(R)
MH MANHOLE
MID MIDDLE
MIN MINIMUM
MISC MISCELLANEOUS
MLTP MULTIPLE
MO MASONRY OPENING
MP MASONRY PIER
MTL METAL
N NORTH
NF NEAR FACE
NIC NOT IN CONTRACT
NM NORMAL
No. NUMBER
NOM NOMINAL
NS NEAR SIDE
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
OPNG OPENING
OPH OPPOSITE HAND
OZ OUNCE
PART PARTITION
PCF POUNDS PER CUBIC FOOT
PCI POUNDS PER CUBIC INCH
PEMB PRE-ENGINEERED METAL BUILDING
PERF PERFORATED
PERM PERIMETER
PL PLATE
PLF POUNDS PER LINEAR FOOT
PLYWD PLYWOOD
PRCST PRECAST
PREFAB PREFABRICATED
PREMLD PREMOLDED
PROP PROPERTY
PROT PROTECT(ED)(ION)
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PSIG POUNDS PER SQUARE INCH GAUGE
PT POINT
PVMT PAVEMENT
QTY QUANTITY
RAD RADIUS OR RADII
RD ROOF DRAIN
RE: REFER TO
REC RECESSED
REINF REINFORCE, REINFORCING OR REINFORCEMENT
REQ'D REQUIRED
REV REVISE OR REVISION
RF ROOF
SYMBOLS
CL
PL
S( ) L( ) C( )
LL( )
HSS( )
MC( )
WT( )
W( )
EQUAL
STRUCTURAL TEE
WIDE FLANGE
PLATE
ANGLE
HOLLOW STRUCTURAL SECTION
MISCELLANEOUS CHANNEL
DOUBLE ANGLE
CHANNEL
AMERICAN STANDARD SHAPE
PERPENDICULAR
PERCENT
PARALLEL
NUMBER
DIAMETER
ELEVATION
DEGREE
AT
CENTERLINE
ANGLE
K( ) OPEN WEB STEEL JOIST
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S T
E M
S C
O M
M A
N D
DRAWFORM REVISION: 25…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .