Attachment E 649-18-105 Combined Drawings.pdf
PDF 19 MB Posted
- Attached to
- Z2DA--Project 649-18-105 Replace Main Hospital Electrical Service Federal contract opportunity
- Solicitation number
- 36C26223B0009
About this file
This document outlines a federal contract opportunity from the Department of Veterans Affairs to replace the main hospital electrical service. Solicitation number 36C26223B0009 seeks to award a contract for project 649-18-105, which involves replacing the entire main electrical service for a Veterans Health Administration hospital. The opportunity is open to all offerors and involves upgrading the hospital's electrical infrastructure to ensure reliable power delivery and support future needs. The selected contractor will be responsible for demolishing the existing electrical equipment and installing a new main service entrance facility, switchgear, and all associated wiring, conduits, cables and connections. The award date is not specified but the work must be completed on an aggressive schedule with minimal disruption to hospital operations.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Attachment J 649-18-105 RFI Questions and Answers (3).pdf | ||
| 36C26223B0009 0006.docx | DOCX document | |
| Attachment I 649-18-105 Specification 11 12 33 - Parking Gates.pdf | ||
| 36C26223B0009 0005.docx | DOCX document | |
| 36C26223B0009 0004.docx | DOCX document | |
| Attachment H 649-18-105 RFI Questions and Answers Continued.pdf | ||
| Attachment G 649-18-105 RFI Questions and Answers.pdf | ||
| 36C26223B0009 0003.docx | DOCX document | |
| 36C26223B0009 0002.docx | DOCX document | |
| 36C26223B0009 Job Walk Sign Sheet.pdf | ||
| 36C26223B0009 0001.docx | DOCX document | |
| Attachment C 649-18-105 Specifications Bid Documents.pdf | ||
| Attachment D 649-18-105 Construction Statement of Work.pdf | ||
| Attachment B SOW 649-18-105 Replace Hospital Electrical Service.pdf | ||
| Attachment A 649-18-105 Bid Set Narratives.pdf | ||
| 36C26223B0009_1.docx | DOCX document | |
| Attachment F 649-18-105 Wage Determination AZ20230034.pdf |
Show all 17
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
U.S. DEPARTMENT OF VETERANS AFFAIRS
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
CERTIFICATE OF AUTHORITY NO. 20013-0
EXP. 09/30/2022
STRUCTURAL / CIVIL ENGINEER
H2B, INC.
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(314) 436-9492
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
SPUR #: 1395.29
/4
/2
:4
:4
P
M
COVER SHEET
ECOAJS
BID DOCUMENTS
REPLACE HOSPITAL (B107) ELECTRICAL
SERVICE
VA PROJECT NUMBER: 649-18-105
REPLACE HOSPITAL (B107)
ELECTRICAL SERVICE
08/05/2022
649-18-105
NORTHERN ARIZONA VA HEALTH
CARE SYSTEM
500 AZ-89, PRESCOTT, AZ 86301
NORTHERN ARIZONA VA HEALTH CARE SYSTEM
500 AZ-89, PRESCOTT, AZ 86301
BID DOCUMENTS
G-000
LOCATION PLAN
SHEET
SEQUENCE
SHEET
NUMBER
SHEET NAME
1-5 Unnamed
[01] GENERAL
1 G-000 COVER SHEET
2 G-001 GENERAL INFORMATION
[02] ENVIROMENTAL
3 HA000 ENVIRONMENTAL HAZARDS - GENERAL NOTES
4 HA100 GROUND FLOOR - ENVIROMENTAL HAZARDS
[03] CIVIL
5 CS000 TOPOGRAPHIC SURVEY
6 CS100 CIVIL OVERALL SITE PLAN
7 CS101 CIVIL ENLARGED SITE & ENTRY PLAN
8 CS102 CIVIL ENLARGED SITE & ENTRY DIMENSION PLAN
9 CI001 MISCELLANEOUS DETAILS
10 CI002 MISCELLANEOUS DETAILS
11 CI003 MISCELLANEOUS DETAILS
[04] STRUCTURAL
12 SA001 STRUCTURAL GENERAL NOTES
13 SA030 TYPICAL DETAILS
14 SD100 STRUCTURAL DEMOLITION PLAN
15 SS101 TRANSFORMER PAD PLAN
16 SS501 EXISTING WALL OPENING DETAILS
[05] ARCHITECTURE
17 AS001 ARCHITECTURAL SITE PLAN
18 AE101 FLOOR PLAN AND RCP - ELECTRICAL ENCLOSURE
19 AE601 WALL PARTITION, DETAILS, DOOR & ROOM FINISH SCHEDULE
[06] MECHANICAL
20 M-000 LEGEND AND ABBREVIATIONS
21 M-101 MECHANICAL DEMOLITION AND NEW WORK PLAN
22 M-501 MECHANICAL DETAILS AND SCHEDULES
23 M-701 MECHANICAL CONTROLS
[07] FIRE PROTECTION
24 FA001 FIRE ALARM/MASS NOTIFICATION GENERAL NOTES
25 FA101 FIRE ALARM PLANS
26 FX101 FIRE SUPPRESSION HAZARD CLASSIFICATION PLAN GROUND FLOOR PLAN
[08] ELECTRICAL
27 E-000 LEGEND AND ABBREVIATIONS
28 E-001 ELECTRICAL SITE PLAN
29 E-100 ELECTRICAL POWER PLAN – BASEMENT
30 E-101 ELECTRICAL POWER PLAN – FIRST FLOOR
31 E-104 ELECTRICAL POWER PLAN – FOURTH FLOOR
32 E-401 ELECTRICAL ENLARGED PLAN – GATE
33 E-402 ELECTRICAL ENLARGED PLAN – CHILLER YARD
34 E-403 ELECTRICAL ENLARGED PLAN - BASEMENT - DEMO
35 E-404 ELECTRICAL ENLARGED PLAN – BASEMENT
36 E-501 ELECTRICAL DETAILS
37 E-601 ELECTRICAL ONE-LINE DIAGRAM - DEMOLITION
38 E-602 ELECTRICAL ONE-LINE DIAGRAM - NEW WORK
TOTAL SHEETS: 39
No. REVISION DESCRIPTION DATE
01 38
ABBREVIATIONS CODES STANDARDS AND EXECUTIVE ORDERS
4'
M A
X
4'
M A
X
2'
0"
M A
X
2'
M
IN
1' - 6" MIN
1. GENERAL CONTRACTOR TO PROVIDE METAL SUPPORT
BLOCKING FOR ALL WALL MOUNTED ACCESSORIES,
FIXTURES, AND EQUIPMENT.
2. PROVIDE ADA SUPPORT BRACKETS PLACED AT ALL OPEN
COUNTERTOPS @ 36"-48" MAX ON CENTER.
3. SPECIFIED MAXIMUMS ARE MEASURED FROM AFTER
FINISHED FLOOR TO THE OPERABLE PART OF THE FIXTURE.
4. FIXTURES SHOWN ARE REPRESENTATIONAL ONLY. NOT ALL
FIXTURES MAY BE USED. REFER TO SPECIFICATIONS FOR
FIXTURE TYPES USED IN THIS PROJECT.
5. FIXTURES MAY OVERLAP WAINSCOT. WHERE APPLICABLE,
BACKING TO BE PROVIDED AS SHIM FOR FLUSH
APPLICATION. SHIM TO MATCH SCHEDULED WALL FINISH.
6" MAX
9" M
IN
SHOWER
VA TOILET ROOM
TURNING RADIUS
DRINKING
FOUNTAIN
PAPER TOWEL
DISPENSER
SANITARY
NAPKIN
DISPENSER
4'
"M
A X
WASTE
RECEPTACLE
LAVATORY
WITH MIRROR
ON CENTER
WALL
4'
M A
X
SOAP
DISPENSER
2' -1
0" M
A X
T O
B .O
. R E
F
LE
C T
IV
E
S U
R F
A C
E
3'
"M
A X
17 MIN
2'
M
IN
3'
M A
X
1' - 6" MIN
WALL
2'
" 4'
M
IN
2' - 0" MIN
8" MIN
WALL
LAVATORY
WITH APRON
1'
M A
X
1' - 6" MIN
URINAL
WALL
1'-5" - 1'-7" (AMBULATORY)
1'-4" - 1'-6" (WHEELCHAIR)
CLEAR FLOOR
5' - 6"
CLEAR FLOOR
6' - 0"
3' - 0" MIN
2'
3'
-0
1' - 0" MIN
3' - 6" MIN 1' - 0"MAX
4' - 6" MIN
1'
'-7
1' -6
M
IN
A N
S I I
C C
A
7.
1)
1' -3
M
IN
A D
A /A
B A
2'
'-0
WALL
WALL
4'
M A
X
WALL HOOK
7'
CLOCK
WALL
FINISHED FLOOR
FIRE EXTINGUISHER
CABINET
WEIGHT > 40LBS
FIRE EXTINGUISHER
CABINET
WEIGHT < 40LBS
4'
"M
A X
4'
M A
X
TOILET SEAT
COVER
DISPENSER
BABY
CHANGING
STATION
CLEAR FLOOR SPACE
@ WATER CLOSET
5' - 6"
2' - 6"
4'
2' - 6"
4'
HANDRAILS AND
BUMPERGUARDS
FIXTURE MOUNTING HEIGHTS AND CLEARANCES
18" MIN
M
IN
FRONT APPROACH,
PULL SIDE
36" MIN
M
IN
HINGE APPROACH,
PULL SIDE
HINGE APPROACH,
PULL SIDE
*12" MIN48
M
IN
FRONT APPROACH,
PUSH SIDE
M
IN
HINGE APPROACH,
PUSH SIDE
22" MIN 24" MIN
*4 8"
M
IN
LATCH APPROACH,
PULL SIDE
24" MIN*4
2"
M
IN
LATCH APPROACH,
PUSH SIDE
*IF BOTH CLOSER
AND LATCH ARE
PROVIDED
*54" MIN IF CLOSER
IS PROVIDED
*48" IF CLOSER IS
PROVIDED
FRONT APPROACH,
PUSH SIDE
M
IN
42" MIN
DOOR AND FIXTURE CLEARANCES
MATERIALS LEGEND
PURPOSE: THE PUBLIC BUILDINGS AMENDMENT ACT OF 1988, PUBLIC LAW (PUB. L.) 100-678 REQUIRES FEDERAL AGENCIES TO FOLLOW NATIONAL RECOGNIZED "MODEL" BUILDING CODES. THE FEDERAL PARTICIPATION IN THE DEVELOPMENT AND USE OF VOLUNTARY STANDARDS, OFFICE OF MANAGEMENT AND BUDGET (OMB) CIRCULAR A-119, REQUIRES ALL EXECUTIVE AGENCIES TO RELY ON VOLUNTARY STANDARDS, BOTH DOMESTIC AND INTERNATIONAL, WHENEVER FEASIBLE, AND TO PARTICIPATE IN
VOLUNTARY STANDARD BODIES.
GENERAL: VA HAS ADOPTED THE LATEST EDITION OF THE FOLLOWING CODES AND STANDARDS AS A MINIMUM FOR ALL PROJECTS PERFORMED IN THE MODERNIZATION, ALTERATION, ADDITION, OR IMPROVEMENT OF ITS REAL PROPERTY AND THE CONSTRUCTION OF NEW STRUCTURES. VA DESIGN MANUALS AND MASTER SPECIFICATIONS
SPECIFY OTHER CODES AND STANDARDS THAT VA FOLLOWS ON ITS PROJECTS:
• VA DIRECTIVES, DESIGN MANUALS, MASTER SPECIFICATIONS, VA NATIONAL CAD STANDARD APPLICATION GUIDE, AND OTHER GUIDANCE ON THE TECHNICAL
INFORMATION LIBRARY (TIL) (HTTP://WWW.CFM.VA.GOV/TIL/).
• 2020 VA PHYSICAL SECURITY & RESILIENCY DESIGN MANUAL, REVISED MARCH 2022
• 2021 INTERNATIONAL BUILDING CODE (IBC) (ONLY WHEN SPECIFICALLY REFERENCED IN VA DESIGN DOCUMENTS, SEE NOTES BELOW)
• 2021 INTERNATIONAL EXISTING BUILDING CODE (IEBC) (IF APPLICABLE)
• 2021 NFPA 101 LIFE SAFETY CODE (SEE NOTES BELOW)
• 2021 NATIONAL FIRE CODES (NFPA)
• OCCUPATIONAL, SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARDS.
• 2020 VA SEISMIC DESIGN REQUIREMENTS, H-18-8
• 2021 INTERNATIONAL MECHANICAL CODE
• 2020 NATIONAL ELECTRICAL CODE (NEC), NFPA 70
• 2021 INTERNATIONAL PLUMBING CODE (IPC)
• 2016 SAFETY CODE FOR ELEVATORS AND ESCALATORS, AMERICAN SOCIETY OF MECHANICAL ENGINEERS (ASME) A 17.1.
• 2015 ARCHITECTURAL BARRIERS ACT (ABA) STANDARDS INCLUDING VA SUPPLEMENT, VA BARRIER FREE DESIGN STANDARD (PG-18-13)
• 2017 ANSI ICC A117.1 ACCESIBLE AND USABLE BUILDINGS AND FACILITIES
• 2019 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE AND COMMENTARY, AMERICAN CONCRETE INSTITUTE AND COMMENTARY (ACI 318-19)
• 2017 STEEL CONSTRUCTION MANUAL (15TH EDITION), AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC)
• ENERGY POLICY ACT OF 2005 (EPACT)
• 2007 DOE INTERIM FINAL RULE: ENERGY CONSERVATION STANDARDS FOR NEW FEDERAL, COMMERCIAL AND MULTI-FAMILY HIGH-RISE RESIDENTIAL BUILDINGS AND
NEW LOW-RISE RESIDENTIAL BUILDINGS, 10 CFR PARTS 433, 434 AND 435.
• 2006 FEDERAL LEADERSHIP IN HIGH PERFORMANCE AND SUSTAINABLE BUILDINGS: MEMORANDUM OF UNDERSTANDING (MOU)
• 2018 EXECUTIVE ORDER 13834: EFFICIENT FEDERAL OPERATIONS
• 2021 THE PROVISIONS FOR CONSTRUCTION AND SAFETY SIGNS. STATED IN THE GENERAL REQUIREMENTS SECTION 010000 OF THE VA MASTER CONSTRUCTION
SPECIFICATION.
• 2019 VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY – ASHRAE STANDARD 62.1
• 2019 SAFETY STANDARD FOR REFRIGERATION SYSTEMS – ASHRAE STANDARD 15
LOCAL CODES: AS AN AGENCY OF THE FEDERAL GOVERNMENT, VA IS NOT SUBJECT TO LOCAL IMPOSITION OF CODE ENFORCEMENT PROCEDURES (DRAWING REVIEWS, BUILDING PERMITS, INSPECTIONS, FEES, ETC.). VA MUST FUNCTION AS THE AUTHORITY HAVING JURISDICTION (AHJ) AND THUS HAS THE RESPONSIBILITY TO GUARD PUBLIC HEALTH AND SAFETY THROUGH ENFORCING ITS ADOPTED CODES. HOWEVER, LOCAL AUTHORITIES SHOULD BE NOTIFIED ABOUT PLANNED PROJECTS AND GIVEN OPPORTUNITY TO REVIEW DRAWINGS PROVIDED THAT VA DOES NOT PAY FOR REVIEW OR INSPECTION FEES.
NOTES:
1. NFPA 101 PRIMARILY ADDRESSES LIFE SAFETY AND FIRE PROTECTION FEATURES WHILE THE IBC ADDRESSES A WIDE RANGE OF CONSIDERATIONS, INCLUDING, BUT
NOT LIMITED TO, STRUCTURAL STRENGTH, SEISMIC STABILITY, SANITATION, ADEQUATE LIGHT AND VENTILATION, AND ENERGY CONSERVATION. VA BUILDINGS MUST MEET THE REQUIREMENTS OF NFPA 101 AND DOCUMENTS REFERENCED BY NFPA 101 IN ORDER TO COMPLY WITH THE ACCREDITATION REQUIREMENTS OF THE JOINT COMMISSION. THEREFORE, DESIGNS SHALL COMPLY WITH THE REQUIREMENTS OF THE LATEST EDITION OF NFPA 101 AND DOCUMENTS REFERENCED THEREIN.
DESIGN FEATURES NOT ADDRESSED BY NFPA 101 OR DOCUMENTS REFERENCED THEREIN SHALL COMPLY WITH THE REQUIREMENTS OF THE LATEST EDITION OF THE IBC OR AS OTHERWISE ADDRESSED ABOVE IN THIS PROGRAM GUIDE. FOR DESIGN FEATURES THAT ARE ADDRESSED BY BOTH THE IBC AS WELL AS NFPA 101 OR A DOCUMENT REFERENCED BY NFPA 101, THE REQUIREMENTS OF NFPA 101 OR THE DOCUMENT REFERENCED BY NFPA 101 SHALL BE USED EXCLUSIVELY (THIS APPLIES
EVEN IF THE IBC REQUIREMENTS ARE DIFFERENT).
2. CONFLICTS BETWEEN NATIONALLY RECOGNIZED CODES AND STANDARDS AND VA REQUIREMENTS – SHOULD A CONFLICT EXIST BETWEEN VA REQUIREMENTS AND VA ADOPTED NATIONALLY RECOGNIZED CODES AND STANDARDS, THE CONFLICT SHALL BE BROUGHT TO THE ATTENTION OF VA. THE RESOLUTION OF THE CONFLICT SHALL BE MADE BY THE AUTHORITY HAVING JURISDICTION FOR VA TO ENSURE A CONSISTENCY SYSTEM WIDE.
ASHRAE 90.1 - 2019 EDITION
BUILDING LOCATION: PRESCOTT, AZ
CLIMATE ZONE (TABLE ANNEX 1-1): ZONE 7B
INTERIOR DESIGN CONDITIONS:
THE INTERIOR DESIGN TEMPERATURES FOR HEATING AND COOLING AS DEPICTED IN THE PROJECT DESIGN CONDITIONS SCHEDULE IN THE MECHANICAL CONTROL DRAWINGS SHALL BE THE MAXIMUM
AND MINIMUM VALUES FOR THE ASSOCIATED TEMPERATURE CONTROL ZONES.
BUILDING ENVELOPE REQUIREMENTS (5.5 )
BUILDING ENVELOPE REQUIREMENTS FOR CLIMATE ZONE 7 (A,B,C)
ROOFS REQUIRED DESIGNED
INSULATION: R-30 c.i. EXISTING METAL BUILDINGS: R-19 + R-11 Ls or R-25 + R-8 Ls EXISTING
ATTIC AND OTHER: R-49 EXISTING
WALLS, ABOVE GRADE
MASS: R-9.5 c.i. EXISTING METAL BUILDING: R-0 + R-15.8 c.i. EXISTING STEEL-FRAMED: R-13 + R-7.5 c.i. EXISTING WOOD-FRAMED AND OTHER: R-13 + R-3.8 c.i. or R-20 EXISTING
WALL, BELOW GRADE
BELOW-GRADE WALL: R-7.5 c.i. EXISTING
FLOORS
MASS: R-14.6 c.i. EXISTING
STEEL-FRAMED: R-30 EXISTING
WOOD-FRAMED AND OTHER: R-30 EXISTING
SLAB-ON-GRADE FLOORS
UNHEATED SLABS: R-15 for 24 in. EXISTING HEATED SLABS: R-20 for 24 in. EXISTING
OPAQUE DOORS
SWINGING: U-0.370 EXISTING
NONSWINGING: U-0.310 EXISTING
FENESTRATION (TABLE 5.5-4):
VERTICAL FENESTRATION, U-FACTOR
FIXED: U-0.36 EXISTING
OPERABLE: U-0.45 EXISTING
ENTRANCE DOOR: U-0.63 EXISTING
DEFINITIONS
c.i = CONTINUOUS INSULATION Ls = LINEAR SYSTEM
NR = NO (INSULATION) REQUIREMENT
ENERGY REQUIREMENTS
N
1. DRAWINGS ARE PART OF A COMPLETE DOCUMENTS SET. CONTRACTOR SHALL
CONFIRM ALL ITEMS REQUIRED BASED UPON THE OVERALL DESIGN INTENT OF THE
ENTIRE DOCUMENT SET.
2. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS, PRIOR TO BEGINNING ANY
WORK, TO CONFIRM THE ACCURACY OF THE DRAWINGS AND REPORT ANY
DISCREPANCIES TO THE ARCHITECT. DO NOT SCALE THE DRAWINGS. FIELD VERIFY
ALL DIMENSIONS AND EXISTING STRUCTURAL CONDITIONS.
3. ALL AREAS NOT INVOLVED IN THE SCOPE OF WORK FOR THIS PROJECT SHALL BE KEPT
CLEAN AND FREE OF OBSTRUCTIONS AT ALL TIMES.
4. ERECT BARRICADES AND WARNING SIGNS TO DIVERT AND WARN PASSERS-BY OF THE
CONSTRUCTION WORK. PROVIDE DUST PROOFING ENCLOSURES TO SEPARATE WORK
AREAS FROM THE EXISTING FACILITIES.
5. ALL TRASH AND DEBRIS TO BE REMOVED ON A DAILY BASIS.
6. PROVIDE PROTECTION FOR ALL EXISTING SURFACES AND CONDITIONS TO REMAIN IN
PLACE DURING THE SCOPE OF WORK. SHOULD ANY DAMAGE OCCUR, PATCH AND
REPAIR ANY DAMAGE TO ADJACENT FINISHES TO MATCH EXISTING.
7. ANY DAMAGE CAUSED TO THE BUILDING OR OWNER EQUIPMENT SHALL BE REPAIRED
OR REPLACED BACK TO ITS ORIGINAL CONDITIONS AT NO ADDITIONAL COST TO THE
OWNER.
8. COVER ALL RETURN AIR GRILLES WITHIN THE AREA OF CONSTRUCTION TO PREVENT
PARTICULATE MATERIAL FROM EXHAUSTING INTO SURROUNDING SPACES.
9. APPROPRIATE LIGHT FIXTURES SHALL BE TEMPORARILY SUSPENDED TO PROVIDE
ADEQUATE LIGHTING LEVELS FOR CONSTRUCTION.
10. CONTRACTOR AND SUBCONTRACTORS ARE REQUIRED TO COORDINATE WITH OTHER
DISCIPLINES TO INSTALL COMPLETE AND OPERATIONAL SYSTEMS. DRAWINGS, AS A
WHOLE, REPRESENT A COMPLETE SET AND DEPICT REQUIREMENTS FOR COMPLETE
AND OPERATIONAL SYSTEMS. INDIVIDUAL DRAWINGS MAY NOT DEPICT COMPLETE AND
ACCURATE INFORMATION TO COORDINATE COMPLETE AND OPERATIONAL SYSTEMS,
BUT DO SO AS AN ENTIRE DOCUMENT TO BE REFERENCED WITH OTHER INDIVIDUAL
DRAWINGS. CONTRACTOR AND SUBCONTRACTORS ARE REQUIRED TO REFERENCE
OTHER SHEETS AND SPECIFICATIONS AS AN ENTIRE SET OF CONSTRUCTION
DOCUMENTS THAT REFLECT WORK REQUIRED TO ACHIEVE A COMPLETE AND
OPERATIONAL GOAL. LACK OF COORDINATION AND REVIEW OF DRAWINGS AND
SPECIFICATIONS AS AN ENTIRE DOCUMENT TO INSTALL COMPLETE AND OPERATIONAL
SYSTEMS, BEING OBVIOUS AND TYPICAL INDUSTRY STANDARD, IDENTIFIED IN THE
DRAWINGS AND SPECIFICATIONS, SHALL NOT BE IN ANY WAY AN ADDITIONAL COST TO
THE GOVERNMENT.
11. CONTRACTOR SHALL SUBMIT A REQUEST, IN WRITING, TO INTERRUPT ANY SUCH
SERVICES TO COR (CONTRACTING OFFICER’S REPRESENTATIVE) 48 HOURS IN
ADVANCE OF PROPOSED INTERRUPTION. REQUEST SHALL STATE REASON, DATE,
EXACT TIME OF, AND APPROXIMATE DURATION OF SUCH INTERRUPTION. MAJOR
INTERRUPTIONS OF ANY SYSTEM MUST BE REQUESTED, IN WRITING, AT LEAST 60
CALENDAR DAYS PRIOR TO THE DESIRED TIME AND SHALL BE PERFORMED AS
DIRECTED BY THE COR. MAJOR INTERRUPTIONS SHALL BE COORDINATED WITH OTHER
MAJOR INTERRUPTIONS AND MAY NOT BE SCHEDULED FOR ONE DISCIPLINE MORE
THAN TWICE THROUGHOUT THE OVERALL CONSTRUCTION SCHEDULE UNLESS
REQUESTED IN WRITING AND APPROVED BY THE COR. CONTRACTOR WILL BE ADVISED,
IN WRITING, OF APPROVAL OF REQUEST, OR OF WHICH OTHER DATE AND/OR TIME
SUCH INTERRUPTION WILL CAUSE THE LEAST INCONVENIENCE TO OPERATIONS OF
THE MEDICAL CENTER. INTERRUPTION TIME APPROVED BY THE MEDICAL CENTER MAY
OCCUR AT TIMES OTHER THAN CONTRACTOR'S NORMAL WORKING HOURS. SCHEDULE
INTERRUPTION MAY BE ON WEEKENDS OR LATE HOURS AND MAY NOT BE AN
ADDITIONAL COST TO THE GOVERNMENT. COORDINATE ALL INTERRUPTIONS THAT MAY
AFFECT THE NORMAL OPERATION OF THE FACILITY WITH THE COR WHEN SUBMITTING
THE CONSTRUCTION SCHEDULE OR UPDATES TO THE CONSTRUCTION SCHEDULE.
12. NO ASBESTOS CONTAINING MATERIALS ARE TO BE USED ON THIS PROJECT. SPUR
DESIGN, THE A/E OF RECORD, CAN CERTIFY THAT NO ASBESTOS CONTAINING
BUILDING MATERIALS (ACBM) OR LEAD BASED PAINT (LBP) PRODUCTS WERE
DESIGNED/SPECIFIED AS BUILDING MATERIAL IN ANY OF THE CONSTRUCTION
DOCUMENTS.
13. REFER TO THE DESIGN BINDER FOR THE ICRA INFORMATION DOCUMENTATION.
GENERAL NOTES
AREA NAME
150 SF
A101
A101
SIM
A
00.0
A101
1 1
A101
LEVEL NAME
00'-00"
00'-00" 4B
3A
FIBERGLASS BATT
INSULATION
RIGID INSULATION
CONCRETE / PRECAST
CONCRETE
EARTH / SOIL
SAND, EIFS FINISH, OR
PLASTER FINISH
GYPSUM BOARD FINISH
BRICK
CONCRETE MASONRY
UNIT
STONE / CAST STONE
GYPSUM BOARD SECTION
EXTERIOR SHEATHING
BOARD SECTION
PLYWOOD SECTION
CLEAN UTILITY
000A
150 SF
/1 A101
X0000
6"
3'
M A
X
ROOM TAG
AREA TAG
SPECIALTY EQUIPMENT TAG
DOOR TAG
KEYED NOTE TAG
WALL TAG
WINDOW TAG
A101
SIM
A101
SIM
A
ACB ACOUSTIC CEILING BAFFLE
ACP ACOUSTIC CEILING PANEL
ACST ACOUSTIC
ADA AMERICANS WITH DISABILITIES ACT
ACT ACOUSTICAL CEILING TILE
ADDL ADDITIONAL
ADDN ADDITION
ADJ ADJACENT, ADJOINING, OR
ADJUSTABLE
ADMIN ADMINISTRATION
AE ARCHITECT/ENGINEER
AF ACCESS FLOORING
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AHJ AUTHORITY HAVING JURISDICTION
AIA AMERICAN INSTITUTE OF
ARCHITECTS
ALT ALTERNATE
ALT NO ALTERNATE NUMBER
ALUM ALUMINIUM (TRIM)
AMT AMOUNT
APPROX APPROXIMATE
ARCH ARCHITECT
ASC ABOVE SUSPENDED CEILING
AT ACOUSTIC CEILING TILE
AVG AVERAGE
B
BD BOARD
BLDG BUILDING
BLKG BLOCKING
BLT IN BUILT-IN
BOS BOTTOM OF STEEL
BOT BOTTOM
BRKT BRACKET
BTWN BETWEEN
C
CAB CABINET
CAV CAVITY
CBB CONCRETE BACKER BOARD
CD CONSTRUCTION DOCUMENTS
CFM CUBIC FEET PER MINUTE
CFS CUBIC FEET PER SECOND
CG CORNER GUARD
CH BD CHALK BOARD
CIP CAST-IN-PLACE
CJ CONTROL JOINT
CL CENTER LINE
CLG CEILING
CLG HT CEILING HEIGHT
CLR CLEAR
CMU CONCRETE MASONRY UNIT
CO CONTRACTING OFFICER
COL COLUMN
COMM COMMUNICATION
CONC CONCRETE
CONT CONTINUOUS
COORD COORDINATE
COR CONTRACTING OFFICER'S
REPRESENTATIVE
CP CONTRACTOR PROVIDED
CP/CI CONTRACTOR PROVIDED /
CONTRACTOR INSTALLED
CPT CAROET/CARPET TILE
CS CONCRETE SEALED
CSWK CASEWORK
CT CERAMIC TILE
CTB CERAMIC TILE BASE
CTR CENTER
CU FT CUBIC FEET
D
DBL DOUBLE
DEMO DEMOLITION
DEPT DEPARTMENT
DET DETAIL
DIA DIAMETER
DIR DIRECTION
DIST DISTANCE
DOC DOCUMENT
DR DOOR
DS DOWNSPOUT
DWG DRAWING
DWP DIMENSIONAL WALL PANEL
E
EA EACH
EJ EXPANSION JOINT
EL ELEVATION
ELEV ELEVATOR
ENTR ENTRANCE
EPY EPXOY FLOORING
EQ EQUAL
ETR EXISTING TO REMAIN
EX EXISTING
EXP EXPOSED
EXT EXTERIOR
F
FAB FABRIC
FED FEDERAL
FF FINISH FACE
FF EL FINISH FLOOR ELEVATION
FIN FINISH
FIN BS FINISH BOTH SIDES
FIN FLR FINISH FLOOR
FIN GR FINISH GRADE
FIXT FIXTURE
FLDG FOLDING
FLEX FLEXIBLE
FLG FLOORING
FLMT FLUSH MOUNT
FLR FLOOR
FOC FACE OF CONCRETE
FOM FACE OF MASONRY
FP FIRE PROTECTION
FR FIRE RESISTANT
FT FEET
FTG FOOTING
FV FIELD VERIFY
FWC FABRIC WALL COVERING
G
GDR GUARDRAIL
GL GLASS/GLAZING
GRAN GRANITE
GR FL GROUND FLOOR
GT GROUT
GSM GALVANIZED SHEET METAL
GYP BD GYPSUM BOARD
H
HDW HARDWARE
HEPA HIGH EFFICIENCY
PARTICULATE AIR (FILTER)
HM HOLLOW METAL
HORIZ HORIZONTAL
HR HANDRAIL
HT HEIGHT
I
IBC INTERNATIONAL BUILDING CODE
INSUL INSULATION
INT INTERIOR
ILO IN LIEU OF
J
J-BOX JUNCTION BOX
L
LAV LAVATORY
LBS POUND
LDG LANDING
LF LINEAR FEET (FOOT)
LIN LINEAR
LN LINOLEUM
LOC LOCATION
LT LIGHT
LVR LOUVER
LVT LUXURY VINYL TILE
M
MAT CARPET MAT / WALK-OFF MAT
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MEMB MEMBRANE
MFR MANUFACTURER
MID MIDDLE
MIL STD MILITARY STANDARD
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
MOD MODIFY
MTG MOUNTING
MTL METAL
MVBL MOVABLE
N
NA NOT APPLICABLE
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NTS NOT TO SCALE
O
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER
OPNG OPENING
OPP OPPOSITE
OPR OPERABLE
ORD OVERFLOW ROOF DRAIN
ORIG ORIGINAL
P
P PAINT
PA PUBLIC ADDRESS
PBD PARTICLE BOARD
PCF POUNDS PER CUBIC FOOT
PCT PERCENT
PERF PERFORATED
PERIM PERIMETER
PERP PERPENDICULAR
PL PROPERTY LINE
PLAM PLASTIC LAMINATE
PLBG PLUMBING
PNL PANEL
PR PAIR
PRB PROFILE BASE
PRKG PARKING
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PORCELAIN TILE
PWR POWER
Q
QA QUALITY ASSURANCE
QC QUALITY CONTROL
QTY QUANTITY
REFERENCE SYMBOLS IDENTIFICATION TAGS
NOTE: NOT ALL ABBREVIATIONS OR SYMBOLS WILL BE UTILIZED FOR THIS PROJECT.
GRID HEAD AND
LINE
LEVEL INDICATOR
MATCH LINE AND
VIEW REFERENCE
NORTH ARROW W/
PROJECT NORTH
SPOT ELEVATION
DETAIL
SECTION
**48" MIN IF BOTH CLOSER
AND LATCH PROVIDED
WALL
SECTION
BUILDING
SECTION
DETAIL
ELEVATION
INTERIOR
ELEVATION
BUILDING
ELEVATION
1 1
6'
- 0
5'
- 6
BARIATRIC TOILET ROOM
TURNING RADIUS
CLEAR FLOOR SPACE
@ ADA LAVATORY
CLEAR FLOOR SPACE @ ADA
DRINKING FOUNTAIN
4"
6"
3"
6" 1'
6" MAX
7" - 9" 11" MIN
17" - 25"
M
IN
6'
(ANSI ICC A117.1)
39"- 41"
(A N
S I I
C C
A
7.
1)
M
IN
(A N
S I I
C C
A
7.
1)
1"
3'
M A
X
5'
M A
X
R
RAF RESILIENT ATHETIC FLOORING
RB RUBBER BASE/RESILIENT BASE
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
REC RECESSED
REF REFERENCE
REM REMOVABLE
REP REPAIR
REPL REPLACE
REQ REQUIRE
REQD REQUIRED
RES RESINOUS FLOORING
RES-W RESINOUS / EPOXY WALL / CEILING
RF RUBBER FLOORING
RFG ROOFING
RM ROOM
RO ROUGH OPENING
RP RESIN PANEL
RSF RESILIENT SHEET FLOORING
RV ROOF VENT
RWC RIGID VINYL WALLCOVERING
S
SC SPECIALTY COATING
SD STATIC DISSIPATIVE FLOORING/TILE
SCHED SCHEDULE
SECT SECTION
SF SQUARE FOOT (FEET)
SGL SINGLE
SIM SIMILAR
SJ SCORED JOINT
SLNT SEALANT
SM SHEET METAL
SPEC SPECIFICATION
SQ SQUARE
SQ IN SQUARE INCH
SQ YD SQUARE YARD
SS SOLID SURFACE
ST STONE
STD STANDARD
STOR STORAGE
SV SHEET VINYL (ROLLED OR TILE)
T
TEL TELEPHONE
TEMP TEMPORARY
TER TERRAZO
TOF TOP OF FOOTING/ FOUNDATION
TOM TOP OF MASONRY
TOS TOP OF SLAB/ STEEL
U
UNO UNLESS NOTED OTHERWISE
UTIL UTILITY
V
VAR VARIES
VC VA PROVIDED / CONTRACTOR
INSTALLED
VCT VINYL COMPOSITION TILE
VFAT VINYL FACED ACOUSTICLAL TILE
VP VENEERED PLASTER
VT VINYL TILE
VV VA PROVIDED / VA INSTALLED
VWC VINYL WALLCOVERING
VWF VINYL WALL FABRIC
W
W/ WITH
W/O WITHOUT
W/C WATER CLOSET
WC WHEELCHAIR
WD WOOD
WFAB WALL FABRIC
WPM WATERPROOF MEMBRANE
WSF WELDED SHEET FLOOR
X
X BRACE CROSS BRACE
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
CERTIFICATE OF AUTHORITY NO. 20013-0
EXP. 09/30/2022
STRUCTURAL / CIVIL ENGINEER
H2B, INC.
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(314) 436-9492
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
SPUR #: 1395.29
/4
/2
:4
:4
P
M
GENERAL INFORMATION
ECOAJS
BID DOCUMENTS
REPLACE HOSPITAL (B107)
ELECTRICAL SERVICE
08/05/2022
649-18-105
NORTHERN ARIZONA VA HEALTH
CARE SYSTEM
500 AZ-89, PRESCOTT, AZ 86301
G-001
02 38
ENVIRONMENTAL HAZARDS - GENERAL
NOTES
CD
03 38
JR
REPLACE HOSPITAL (B107)
ELECTRICAL SERVICE
08/05/2022
649-18-105
NORTHERN ARIZONA VA HEALTH
CARE SYSTEM
500 AZ-89, PRESCOTT, AZ 86301
Veterans
Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. 62918 EXP. 12/31/2022
MECH ENGR REG. NO. 69943 EXP. 12/31/2022
ELEC ENGR REG. NO. 70271 EXP. 12/31/2022
STRUCTURAL / CIVIL ENGINEER
H2B, INC.
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
o n e e i g h t h i n c h o n e f o o t o n e q u a r t e r i n c h o n e f o o t t h r e e e i g h t h s i n c h o n e f o o t o n e h a l f i n c h o n e f o o t t h r e e q u a r t e r s i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a l f i n c h e s o n e f o o t t h r e e i n c h e s o n e f o o t
No. REVISION DESCRIPTION DATE
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(314) 436-9492
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
STAMP:
HA000
Drawing Number
Building Number
SPUR #: 1395.29
GENERAL NOTES
THE AREA OF WORK SHOWN IS ASSOCIATED WITH AN OPERATING FACILITY THAT MUST REMAIN IN
SERVICE 24 HOURS/7 DAYS A WEEK. ENVIRONMENTAL DRAWINGS ARE LIMITED TO WORK
PERFORMED IN ROOMS 014-016 AND ASSOCIATED OUTSIDE AREA. UP TO 4 NEGATIVE PRESSURE
CONTAINMENTS MAY BE REQUIRED TO FACILTATE PROJECT WORK SCHEDULE.
SEE SHEET G-001 FOR ADDITIONAL INFORMATION REGARDING SCHEDULE AND PHASING
REQUIREMENTS. SCHEDULE WORK TO MINIMIZE DISRUPTION OF SERVICES.
ASBESTOS PIPE INSULATION AND/OR MUDDED FITTINGS (TSI) MAY BE PRESENT WITHIN CHASES AND
ABOVE PLASTER CEILINGS. MAINTAIN 3 FT OF WORK CLEARANCE FROM TSI AND STOP WORK AND
NOTIFY SUPERVISOR WHERE DAMAGE IS OBSERVED.
SUSPECT MOLD WAS NOT OBSERVED USING VISUAL INSPECTION METHOD.
ALTERATIONS TO OR INSTALLATION OF NEW SECTIONS OF CONDUIT OR GROUNDING ARE TO BE
ATTACHED TO THE UNPAINTED STRUCTURAL MEMBERS OR AS DIRECTED USING BEAM CLAMPS OR
SELF TAPING ANCHORS AND PERFORMED BY GENERAL CONTRACTOR. DO NOT INSTALL NEW
SUPPORTS ON LEAD BASED PAINTED WALL OR CEILING SUBSTRATES.
USE EXISTING WALL, FLOOR, AND CEILING PENETRATIONS AND ASSOCIATED CONDUIT SLEEVES AS
REQUIRED. AREAS WITHIN CHASES AND VOIDS OF EXTERIOR BUILDING WALLS ARE GENERALLY
SUSPECT FOR ASBESTOS CONTAINING MATERIALS.
DOORS, DOOR JAMBS, METAL VENTS, STRUCTURAL STEEL, PIPE, WINDOW COMPONENTS, STAIR
SYSTEMS, VARNISH ON WOOD, AND CHAIR RAILS W/ LEAD BASED PAINT ARE GENERALLY NOT
SHOWN ON DRAWINGS FOR CLARITY. PROTECT AS NECESSARY. STRUCTURAL STEEL MEMBERS
WERE NOT ACCESSIBLE, HOWEVER ASSUME LEAD BASED PAINT ON STRUCTURAL STEEL AND USE
BEAM CLAMPS FOR SUSPENSION PURPOSES AS NECESSARY.
EXISTING CONDUITS AND/OR SLEEVES, WHERE PRESENT THROUGH WALLS AND HEADWALLS W/
LEAD BASED PAINT, ARE ASSUMED OF SUFFICIENT SIZE TO ALLOW FOR NEW FEEDER UNLESS
OTHERWISE CALLED FOR NEW OR ADDITIONAL BY KEYNOTE.
ASBESTOS RELATED MATERIALS ARE PRESENT IN THE BUILDING AND NOT SHOWN ON DRAWINGS.
ASBESTOS CONTAINING NOT SHOWN INCLUDE: AREAS OF EXTERIOR WALL SURFACING STUCCO,
SEALANTS ON ROOF, FIRE DOORS, 9" AND 12" FLOOR TILE SYSTEMS, VIBRATION COLLARS, PIPE
INSULATION, MUDDED FITTINGS, AND ASSUMED CERAMIC TILE GROUT IN RESTROOMS. AVOID WORK
THAT WILL IMPACT THESE MATERIALS.
BASED ON REVIEW OF AVAILABLE AS BUILT DRAWINGS, SUBSURFACE UTILITY INSTALLATION
ACTIVITIES ARE NOT EXPECTED TO IMPACT UNKNOWN BURIED UTILITY SYSTEM MATERIALS.
HOWEVER, THE CONTRACTOR SHOULD BE AWARE OF THE POTENTIAL PRESENCE OF BURIED
UTILITY FEATURES THAT ARE KNOWN OR CONSIDERED LIKELY TO CONTAIN ENVIRONMENTAL
HAZARDS, INCLUDING VARIOUS ASBESTOS CONTAINING MATERIALS SUCH AS THERMAL SYSTEM
PIPE INSULATION, CAULKING, SEALANTS, AND CEMENTITIOUS CONDUITS. IN THE EVENT THAT
ENVIRONMENTALLY HAZARDOUS COMPONENTS ARE ENCOUNTERED, THE CONTRACTOR SHALL
NOTIFY THE COR IMMEDIATELY UPON DISCOVERY TO ALLOW FOR PROPER ASSESSMENT BY
TRAINED/CERTIFIED INSPECTORS. FURTHERMORE, THE HANDLING/REMOVAL OF SUCH REGULATED
ENVIRONMENTAL MATERIALS SHALL NOT BE CONSIDERED PART OF THE SCOPE DELINEATED WITHIN
THESE CONTRACT DOCUMENTS AND SHALL BE CONSIDERED A CHANGE IN SCOPE OF WORK.
ABATEMENT NOTES
CONTRACTOR IS TO BE LICENSED TO ENGAGE IN ASBESTOS RELATED
PROJECT WORK AND USE STATE LICENSED/TRAINED PERSONNEL. WHERE
DISTURBING PAINT, PERSONNEL ARE TO BE OSHA TRAINED AND PERFORM
WORK IN ACCORDANCE WITH NEA FOR RRP.
WITHIN AN NPE, HVAC AIR FLOW SHALL BE SHUTDOWN AND DUCT OPENINGS
COVERED WITH CRITICAL BARRIERS THROUGHOUT ABATEMENT. SCHEDULE
SHUTDOWNS WITH THE VACOR TO ACCOMMODATE FACILITY AND
CONSTRUCTION REQUIREMENTS.
ALL AUTHORIZED PERSONNEL WITHIN AN NPE SHALL DON, AT MINIMUM, HALF
FACE AIR PURIFYING RESPIRATORS WITH P100 FILTERS, DISPOSABLE DUST
SUITS (WITH BOOT AND HEAD COVERS) AND GLOVES. RESPIRATORY
PROTECTION MAY REQUIRE USE OF POWERED AIR PURIFYING RESPIRATORS.
REGULATED AREA NEGATIVE PRESSURE ENCLOSURES SHALL BE PREPARED IN
ACCORDANCE WITH THE FOLLOWING:A) ALL FLOORS, CEILINGS AND WALLS
SHALL BE ISOLATED USING SUFFICIENT POLY SHEETING; B) OSHA ASBESTOS
SIGNAGE AT ENTRANCE TO REGULATED AREAS; C)SINGLE-POINT OF ENTRY
WITH 3-STAGE WET DECONTAMINATION STATION TO ALLOW WORKERS TO
REMOVE PPE, WASH AND VACUUM THEMSELVES OFF PRIOR TO EXITING THE
REGULATED WORK AREA; D) MAINTAINED UNDER NEGATIVE PRESSURE (-0.02 IN
WG OR BETTER) USING HEPA FILTERED AIR MACHINES WITH EXHAUST ROUTED
TO OUTDOORS; E) MINIMUM OF 4 AIR CHANGES PER HOUR; F) CLEAN/CHANGE
ROOM SUFFICIENT FOR WORKERS TO CHANGE INTO STREET CLOTHES (OPAQUE
POLY REQUIRED AS NEEDED FOR PRIVACY); G) RENEWABLE ADHESIVE MATS
IMMEDIATELY OUTSIDE OF REGULATED WORK AREA TO ENSURE FOOT TRAFFIC
DOES NOT SPREAD DUST/DEBRIS TO OTHER AREAS OF FACILITY.
PERFORM ABATEMENT USING THE FOLLOWING CONTROLS: A) HEPA FILTERED
VACUUM FOR CONTINUOUS AND FINAL CLEANUP; B) ONLY MANUAL REMOVAL
MEANS/TOOLS ARE ALLOWED TO DISTURB ACM (MECHANICAL TOOLS
PROHIBITED FOR ACM REMOVAL).
CLEANING OF REGULATED WORK AREAS IS TO INCLUDE HEPA VACUUMING &
WET WIPING METHODS. REGULATED AREAS ARE TO PASS A SUCCESSFUL
VISUAL INSPECTION BY THE VPIH PRIOR TO COLLECTION OF CLEARANCE
SAMPLES.
VPIH WILL PERFORM PERIMETER AIR MONITORING, VISUAL INSPECTIONS AND
FINAL AIR CLEARANCE SAMPLING.
CONTRACTOR TO PERFORM OSHA EMPLOYEE EXPOSURE MONITORING.
WASTE PRODUCED DURING REMEDIATION SHALL BE COLLECTED,
CONTAINERIZED, LABELED, CHARACTERIZED AND DISPOSED IN ACCORDANCE
WITH SPECIFICATION 02.82.11
WASTE CONTAINERS, TOOLS, EQUIPMENT, ETC. SHALL BE WET WIPED PRIOR TO
LEAVING REGULATED WORK AREA.
WHERE THE COMBINED AREA OF THE NPE INCLUDING , DECONTAMINATION,
LOADOUT, AND WORK CHAMBERS DOES NOT FIT WITHIN A ROOM, THE
DECON/LOADOUT CONFIGURATION MAY EXTEND INTO 1/2 WIDTH OF THE
HALLWAY AS REQUIRED TO ALLOW PASSAGE IN CORRIDOR.
BID DOCUMENTS
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text F
GROUND FLOOR - ENVIRONMENTAL
HAZARDS
CD
04 38
A
M
JR
REPLACE HOSPITAL (B107)
ELECTRICAL SERVICE
08/05/2022
649-18-105
NORTHERN ARIZONA VA HEALTH
CARE SYSTEM
500 AZ-89, PRESCOTT, AZ 86301
Veterans
Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. 62918 EXP. 12/31/2022
MECH ENGR REG. NO. 69943 EXP. 12/31/2022
ELEC ENGR REG. NO. 70271 EXP. 12/31/2022
STRUCTURAL / CIVIL ENGINEER
H2B, INC.
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
o n e e i g h t h i n c h o n e f o o t o n e q u a r t e r i n c h o n e f o o t t h r e e e i g h t h s i n c h o n e f o o t o n e h a l f i n c h o n e f o o t t h r e e q u a r t e r s i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a l f i n c h e s o n e f o o t t h r e e i n c h e s o n e f o o t
No. REVISION DESCRIPTION DATE
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(314) 436-9492
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
STAMP:
HA100
Drawing Number
Building Number
SPUR #: 1395.29
ELEVATOR
#1
PIT
X-FMR
PM-5
X-FMR
PM-4
X-FMR
PM-14
BUILDING 107, GROUND FLOOR DRAWING
A7
A1
L1
A2
A6
A3
L3
L2
A6
KEY PLAN
A5
A5
A5
A5
A4
HAZARDOUS MATERIAL KEY NOTES
REMOVE WINDOW ASSEMBLY FRAMING WITH HIDDEN ASBESTOS CAULKS WITHIN
A NEGATIVE PRESSURE ENCLOSURE, 1 WINDOW ASSEMBLY AND 1 ENCLOSURE.
REMOVE EXTERIOR ASBESTOS STUCCO USING MANUAL MEANS SUFFICIENT FOR
NEW DOORWAY AND RELATED ACCESSORIES ALL PERFORMED WITHIN A
NEGATIVE PRESSURE ENCLOSURE. COORDINATE EXTENTS WITH THE GENERAL
CONTRACTOR, 50 SF.
REMOVE LOUVER AND HOLE COVER WITH HIDDEN ASBESTOS CAULKS AND
ASBESTOS STUCCO IN SUBSTRATE POCKET USING MANUAL MEANS WITHIN A
NEGATIVE PRESSURE ENCLOSURE, 1 LOUVER ASSEMBLY.
REMOVE LOUVER AND HOLE COVER WITH HIDDEN ASBESTOS CAULKS AND
REMAINING ASBESTOS STUCCO IN SUBSTRATE POCKET USING MANUAL MEANS
WITHIN A NEGATIVE PRESSURE ENCLOSURE, 1 LOUVER ASSEMBLY.
PROVIDE ATTACHMENTS AND PENETRATIONS THROUGH ASBESTOS STUCCO
AND PLASTER PERIMETER WALL WITHIN A NEGATIVE PRESSURE ENCLOSURE, 8
LOCATIONS 1 SF EACH (8 SF) AND 1 ENCLOSURE. COORDINATE EXTENTS AND
LOCATIONS RELATED TO TOP-HAT, MINI-SPLIT, SECURITY DOOR LOCKS AND FIRE
SYSTEM ELEMENTS WITH THE GENERAL CONTRACTOR.
EXTERIOR ASBESTOS STUCCO (SURFACING) PRESENT ON BUILDING 107. USE
EXISTING WALL SLEEVES WHERE AVAILABLE, DO NOT DISTURB AND PROTECT AS
NECESSARY.
INTERIOR ASBESTOS STUCCO WALL SURFACING (CEMENTITIOUS), PROTECT AS
NECESSARY.
USING MANUAL MEANS, REMOVE WINDOW COMPONENTS WITH LEAD BASED
PAINT (LBP) WITHIN THE EXISTING NEGATIVE PRESSURE ENCLOSURE, 1 WINDOW
ASSEMBLY.
REMOVE GAS PIPE WITH YELLOW LBP BY (UNTHREADING) OR SIMILAR LOW
ENERGY MANUAL MEANS WITHIN A NEGATIVE PRESSURE ENCLOSURE.
COORDINATE WITH THE GENERAL CONTRACTOR, 40 LF AND 1 ENCLOSURE.
USING MANUAL MEANS, REMOVE METAL DOOR FRAME WITH LBP WITHIN A
NEGATIVE PRESSURE ENCLOSURE, 1 DOOR FRAME.
2,000 CFM HEPA FILTERED AIR MACHINE WITH SUGGESTED TUBING DIRECTION
3 STAGE WET DECONTAMINATION UNIT W/ SHOWER
NEGATIVE PRESSURE ENCLOSURE
A1
A2
A3
A4
A5
A6
A7
L1
L2
L3
BID DOCUMENTS
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text
NSF
AutoCAD SHX Text
AutoCAD SHX Text
MECHANICAL
AutoCAD SHX Text
AutoCAD SHX Text
NSF
AutoCAD SHX Text
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text
AutoCAD SHX Text
NSF
AutoCAD SHX Text
AutoCAD SHX Text
MECHANICAL
AutoCAD SHX Text
AutoCAD SHX Text
NSF
AutoCAD SHX Text 002A
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
AutoCAD SHX Text
NSF
AutoCAD SHX Text
AutoCAD SHX Text
MECHANICAL
AutoCAD SHX Text
AutoCAD SHX Text
NSF
AutoCAD SHX Text 017A
AutoCAD SHX Text
TELEPHONE
AutoCAD SHX Text
AutoCAD SHX Text
NSF
AutoCAD SHX Text #3
AutoCAD SHX Text
STAIR
AutoCAD SHX Text re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project NumberCONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. 62918 EXP. 12/31/2022
MECH ENGR REG. NO. 69943 EXP. 12/31/2022
ELEC ENGR REG. NO. 70271 EXP. 12/31/2022
STRUCTURAL / CIVIL ENGINEER
H2B, INC.
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(314) 436-9492
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
SPUR #: 1395.29
2/
/2
:3 6:
A
M
BID DOCUMENTS
REPLACE HOSPITAL (B107)
ELECTRICAL SERVICE
08/05/2022
649-18-105
NORTHERN ARIZONA VA HEALTH
CARE SYSTEM
500 AZ-89, PRESCOTT, AZ 86301
No. REVISION DESCRIPTION DATE
TOPOGRAPHIC SURVEY
DMH 5ALL
CS000
U G
E U
G E
UP
UP
UP
W
W
W
W
W
W
W W
W
W
W
W
W
W
W W W W
W W
W
T
T
T
T
T T
T
T
G G
G G
G
G G
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD SD
SD
SD
SD
SD SD
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
SS
SS
SS
SS
SS
SS
SS
SS
SD
UGE
UGE
UGE
UGE U
G
E
UGE
UGE
U G
E
UG
E
UG
E
UG
E
UG
E
UGE
UGE
UGE
UGE
UG
E
UG
E
UG
E
UG
E
UGE
UGE
UGE
HH
HH
HH
HH
L
L
L
MH
UP
RAMP
FO
FO
FO
FO
TT
T
T
S
S
S S
CO
U G
E U
G E
W
W
W
W W
SD
SD
SD
SD
SD
SS
SS
SS
SS
SS
SS
UGE
UGE
UG
E
UG
E
UG
E
SD
S
CWS
CWS
CWS
CWSCWS
CWS
CWS
CWSCWS
CWS
CWS
CWS
CWS W
W
W
W
SD
SD
G G
G
U G
E
S
UGE
UGE
UGE
UGE
S
S
S
E E
E
E
E E
E
E
E
E
E
EE
E
E
E th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project NumberCONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. 62918 EXP. 12/31/2022
MECH ENGR REG. NO. 69943 EXP. 12/31/2022
ELEC ENGR REG. NO. 70271 EXP. 12/31/2022
STRUCTURAL / CIVIL ENGINEER
H2B, INC.
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(314) 436-9492
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
SPUR #: 1395.29
2/
/2
:3 6:
A
M
BID DOCUMENTS
REPLACE HOSPITAL (B107)
ELECTRICAL SERVICE
08/05/2022
649-18-105
NORTHERN ARIZONA VA HEALTH
CARE SYSTEM
500 AZ-89, PRESCOTT, AZ 86301
No. REVISION DESCRIPTION DATE
08/
02/
TOD J.
HENNING
57430
SCALE: 1" = 20'1 OVERALL SITE PLAN
BENCHMARK: .
NOTES: .
LEGEND: .
HELD A CITY OF PRESCOTT PUBLISHED BENCHMARK:
MOL-03 NAVD(88) ELEVATION = 5349.12
FOUND CARRIAGE BOLT WITH 2" WASHER ON TOP OF CURB ON
N.W. CURB RETURN AT S.W. CORNER OF NORTH WASHINGTON
AVENUE AND MOELLER STREET.
1. UTILITIES PRESENTED ON THESE DRAWINGS ARE SHOWN
BASED ON THE BEST AVAILABLE INFORMATION.
CONTRACTOR SHALL VERIFY THE EXACT LOCATIONS IN
THE FIELD PRIOR TO COMMENCING CONSTRUCTION.
CONTRACTOR SHALL NOTIFY LOCAL UTILITY LOCATING
SERVICES AT LEAST 48 HOURS BEFORE PROCEEDING WITH
ANY EXCAVATION.
2. CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGES TO
EXISTING WATER, WASTEWATER, STORMWATER LINES,
AND TRAFFIC CONTROL DEVICES. DAMAGES SHALL BE
REPAIRED AT THE CONTRACTOR'S EXPENSE.
3. ADEQUATE DRAINAGE SHALL BE MAINTAINED AT ALL TIMES
DURING CONSTRUCTION AND ANY DRAINAGE DITCH OR
STRUCTURE DISTURBED DURING CONSTRUCTION SHALL
BE RESTORED TO EXISTING CONDITIONS OR BETTER.
4. CONTRACTOR SHALL TAKE NECESSARY PRECAUTIONS TO
PROTECT ROOT SYSTEMS OF SHRUBS, PLANTS, AND
TREES ALONG THE AREA OF EXCAVATION.
5. CONTRACTOR SHALL COMPLY WITH THE LATEST EDITION
OF OSHA REGULATIONS AND THE STATE OF ARIZONA LAWS
CONCERNING EXCAVATION.
6. CONTRACTOR SHALL PROVIDE CONSTRUCTION AND
SAFETY SIGN PER VA REQUIREMENTS AT LOCATIONS
AROUND THE SITE.
7. CONTRACTOR TO COORDINATE WITH VA FOR LOCATION OF
MATERIAL STOCKPILING AND STAGING AREA.
8. ANTI-RAM BOLLARDS SHALL BE PLACED AT EQUAL
SPACING, AND SHALL NOT HAVE AN OPENING GREATER
THAN 4-FEET.
20' 40'
SCALE: 1" = 20'
EXISTING FIBER OPTIC LINEFO
EXISTING GAS LINEG
EXISTING FUEL LINEO
EXISTING SANITARY SEWERSS
EXISTING STORM DRAINSD
EXISTING TELEPHONE LINET
EXISTING UNDERGROUND ELECTRIC LINEUGE
EXISTING WATER LINEW
EXISTING CHILLED WATER SUPPLY LINECWS
SEE TOPOGRAPHIC SURVEY FOR EXISTING FEATURES LEGEND
NEW ELECTRICAL LINEE
CIVIL OVERALL SITE PLAN
DMH 6ALL
SEE ENLARGED ENTRY PLAN,
SEE SHEET CS101
SEE ENLARGED SITE PLAN,
SEE SHEET CS101
CONTRACTOR STAGING AREA (COORDINATE w/ VA)1
KEYED NOTES: .
2 CONSTRUCTION & SAFETY SIGN (SEE NOTE 6)
CONTRACTOR STAGING AREA
CS100
NEW CAMERA (RE: ELEC)
NEW ASTM F2656 M30 ANTI-RAM BOLLARDS
(RE: ARCH)
NEW REMOVABLE ASTM F2656 M30 ANTI-RAM
BOLLARDS (RE: ARCH)
CO
LO
NE
L
HO
LM
BE
RG
R D
SDMH #8005
RIM=5304.02
NW/SE INV 12" PIPE=5298.49
NE DROP INV 6" PIPE=5299.26
SSMH #8123
RIM=5304.79
SSMH #8126
RIM=5304.53
INV 12" PIPE=5296.85
BUILDING FF=5303.85
BUILDING FACE
UGE
UGE
G
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
FO
SS
SS
SS
SS
SS
SS
SS
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
HH
SD
SD
SD
CWS
CWS
CWS
CWS
CWS
CWS
CWS
CWS
CWS
CWS
CWS
CWS
CWS
CWS
SS
W
W
W
W
W
W
G
UGE
UGE
CO
L.
H
OL
M
BE
RG
R
OA
D
24' PVMT REMOVAL & REPLACEMENT
FOR INSTALLATION OF VEHICLE
GATE ARMS
E
E
E
E
EE
E
E
E
E
P
SEE SHEET CI-003
DETAIL 1
SEE SHEET CI-003
DETAIL 1
FOR INSTALLATION OF VEHICLE
GATE ARMS
24' PVMT REMOVAL & REPLACEMENT
19 3
E
E
E
E
S
S
S
S S
SD
S
S
P P
S
S
P
CO
CO
P
P
PP
PPP
PPP P
P
HAZ-MAT AREA
ST
OR
AG
E
CO
NT
AI
NE
R
AC
U
NI
T
LOAD LIFT
GE
NE
RA
TO
R
GE
NE
RA
TO
R
STAIRS
GREASE TRAP VAULT W/ LIFT PUMP #8003
RIM=5305.36
INV=5296.91
CHILLER RACKS
WITH PIPING
CONCRETE PAD
CONCRETE
PAD
SID
EW
AL
K
BLOCK WALL
RAMP
SSMH #8000
RIM=5306.21
N/S INV 8" PIPE=5302.44
SSMH #8001
RIM=5308.28
W INV 8" PIPE=5302.75
SSMH #8002
RIM=5305.51
INV 6" PIPE=5301.12
NE DROP INV 6" PIPE=5303.11
SE DROP INV 4" PIPE=5303.61
GREASE TRAP VAULT #8004
RIM=5305.32
NW/SE INV 12" PIPE=5298.49
NE DROP INV 6" PIPE=5299.26
BUILDING FF=5306.45
BUILDING FACE
BUILDING FACE
LINE ABANDONED
PER VA STAFF
P
PP
U G
E U
G E
U G
E U
G E
U G
E
UGEUGE
UGE
W
W W
W W
WW
W
W
W
W
W
W
W
W
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
W
W
UGE
UG
E
UGE
SD
SD
SD
SD
UGE
G
G G
G
U G
E
UGE
UGE
UGE
UGE
UG
E
UG
E
UG
E
UG
E
UG
E
U G
E
UGE
SS
E
E
E E
E
E
E
E
E E
E
E E
E
E
E
E
E E
E
E
E
E
E
A
A
R
EXIST TP = 6305.74
EXIST FL 6" SAN SWR = ±5301.86
EXIST TP = 5305.05
EXIST FL 6" SAN SWR = ±5301.28
R
SEE SHEET CI-002
DETAIL 3
13 7 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project NumberCONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. 62918 EXP. 12/31/2022
MECH ENGR REG. NO. 69943 EXP. 12/31/2022
ELEC ENGR REG. NO. 70271 EXP. 12/31/2022
STRUCTURAL / CIVIL ENGINEER
H2B, INC.
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(314) 436-9492
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
SPUR #: 1395.29
2/
/2
:3 6:
A
M
BID DOCUMENTS
REPLACE HOSPITAL (B107)
ELECTRICAL SERVICE
08/05/2022
649-18-105
NORTHERN ARIZONA VA HEALTH
CARE SYSTEM
500 AZ-89, PRESCOTT, AZ 86301
No. REVISION DESCRIPTION DATE
08/
02/
TOD J.
HENNING
57430
SCALE: 1" = 10'1 ENLARGED SITE PLAN
SCALE: 1" = 10'2 ENLARGED ENTRY PLAN
BENCHMARK: .
NOTES: .
LEGEND: .
HELD A CITY OF PRESCOTT PUBLISHED BENCHMARK:
MOL-03 NAVD(88) ELEVATION = 5349.12
FOUND CARRIAGE BOLT WITH 2" WASHER ON TOP OF CURB ON
N.W. CURB RETURN AT S.W. CORNER OF NORTH WASHINGTON
AVENUE AND MOELLER STREET.
1. UTILITIES PRESENTED ON THESE DRAWINGS ARE SHOWN BASED ON
THE BEST AVAILABLE INFORMATION. CONTRACTOR SHALL VERIFY THE
EXACT LOCATIONS IN THE FIELD PRIOR TO COMMENCING
CONSTRUCTION. CONTRACTOR SHALL NOTIFY LOCAL UTILITY
LOCATING SERVICES AT LEAST 48 HOURS BEFORE PROCEEDING WITH
ANY EXCAVATION.
2. CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGES TO EXISTING
WATER, WASTEWATER, STORMWATER LINES, AND TRAFFIC CONTROL
DEVICES. DAMAGES SHALL BE REPAIRED AT THE CONTRACTOR'S
EXPENSE.
3. ADEQUATE DRAINAGE SHALL BE MAINTAINED AT ALL TIMES DURING
CONSTRUCTION AND ANY DRAINAGE DITCH OR STRUCTURE
DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO
EXISTING CONDITIONS OR BETTER.
4. CONTRACTOR SHALL TAKE NECESSARY PRECAUTIONS TO PROTECT
ROOT SYSTEMS OF SHRUBS, PLANTS, AND TREES ALONG THE AREA
OF EXCAVATION.
5. CONTRACTOR SHALL COMPLY WITH THE LATEST EDITION OF OSHA
REGULATIONS AND THE STATE OF ARIZONA LAWS CONCERNING
EXCAVATION.
6. CMU BLAST SCREEN WALLS AND FOUNDATIONS WILL NEED TO BE
ADDED IF VA DENIES DEVIATION PER PSDRM REQUIREMENTS.
EXISTING FIBER OPTIC LINEFO
EXISTING GAS LINEG
EXISTING FUEL LINEO
EXISTING SANITARY SEWERSS
EXISTING STORM DRAINSD
EXISTING TELEPHONE LINET
EXISTING UNDERGROUND ELECTRIC LINEUGE
EXISTING WATER LINEW
EXISTING CHILLED WATER SUPPLY LINECWS
EXISTING PAVEMENT TO BE REMOVED
SEE TOPOGRAPHIC SURVEY FOR EXISTING FEATURES LEGEND
KEYED NOTES: .
NEW UTILITY TRENCH PAVEMENT REMOVAL AND
REPLACEMENT (RE: CI001)
NEW ELECTRICAL TRANSFORMER (RE: MEP)
NEW ELECTRICAL LINE (RE: MEP)
CONNECT NEW ELECTRICAL LINE TO NEW FEATURE
(RE: MEP)
R
DEMOLITION KEY NOTES:
A
SITE KEY NOTES:
FEATURE TO BE ABANDONED
FEATURE TO BE REMOVED
EXISTING FEATURE TO BE ABANDONED|||||
NEW ELECTRICAL LINEE
CONNECT NEW ELECTRICAL LINE TO EXISTING BUILDING
(RE: MEP)5
ADJUST EXISTING MANHOLE TO FINISHED GRADE6
EXISTING UTILITY TO BE PROTECTED7
NEW ELECTRIC HAND HOLE (RE: MEP)8
CIVIL ENLARGED SITE & ENTRY
PLAN
DMH 7ALL
NEW SHALLOW MOUNT ANTI-RAM BOLLARDS SPACED
4' CENTER TO CENTER(RE: 3/CI002) (RE: ARCH)9
NEW VEHICLE BARRIER LIFTMASTER MEGA ARM TOWER
WITH 14-FOOT ARMS, OR APPROVED EQUAL (RE: 2/CI002)
(RE: MEP FOR ELEC. AND TELECOMMUNICATION ROUTING)
NEW SECURITY GATE ISLAND11
NEW 1" CONDUIT DUCT BANK FROM HAND HOLE TO CAMERA
POLE FOR CATEGORY CABLING TO POLE CAMERA, STUB UP
CONDUIT IN POLE. (RE: MEP)
P FEATURE TO BE PROTECTED
NEW 6" CONCRETE CURB (RE: 3/CI001)13
PROVIDE (1) ONE LPR STANDARD RANGE CAMERA.
(RE: MEP)14
PROVIDE (1) ONE 6'X3' ROUND POLE FOR THE MOUNTING
OF A LICENSE PLATE RECOGNITION (LPR) CAMERA.
(RE: MEP)
PROVIDE VEHICLE DETECTION LOOP. (RE: MEP)16
CS101
10' 20'
SCALE: 1" = 10'
EXISTING CONCRETE PAD & STAIRS TO
BE REMOVED
17 NEW ADA RAMP (RE: 4/CI002)
18 REPAIR LANDSCAPE AREA BACK TO EXISTING
CONDITIONS OR BETTER
19 NEW DUAL HEIGHT, GATE ACCESS CONTROL PEDESTAL
(RE: ELEC)
NEW 1" CONDUIT DUCT BANK FROM HAND HOLE TO
ACCESS CONTROL PEDESTAL, STUB UP CONDUIT IN
POLE (RE: ELEC)
NEW CAMERA (RE: ELEC)
NEW ASTM F2656 M30 ANTI-RAM BOLLARDS
(RE: ARCH)
NEW REMOVABLE ASTM F2656 M30 ANTI-RAM
BOLLARDS (RE: ARCH)
NEW CONCRETE SIDEWALK
CONTRACTOR SHALL PROVIDE FULL DEPTH SAWCUT AT ALL
DEMOLITION LIMITS. CONTRACTOR SHALL MATCH ALL
EXISTING PAVEMENT THICKNESSES AND SUBGRADE.
20 NEW TWO-WAY INTERCOM SYSTEM WITH FACIAL
ANALYTICS (RE: ELEC)
S
S
S
S S
SD
S
S
P P
S
S
P
CO
CO
P
P
PP
PPP
PPP P
P
HAZ-MAT AREA
ST
OR
AG
E
CO
NT
AI
NE
R
AC
U
NI
T
LOAD LIFT
GE
NE
RA
TO
R
GE
NE
RA
TO
R
STAIRS
GREASE TRAP VAULT W/ LIFT PUMP #8003
RIM=5305.36
INV=5296.91
CHILLER RACKS
WITH PIPING
CONCRETE PAD
CONCRETE
PAD
SID
EW
AL
K
BLOCK WALL
RAMP
SSMH #8000
RIM=5306.21
N/S INV 8" PIPE=5302.44
SSMH #8001
RIM=5308.28
W INV 8" PIPE=5302.75
SSMH #8002
RIM=5305.51
INV 6" PIPE=5301.12
NE DROP INV 6" PIPE=5303.11
SE DROP INV 4" PIPE=5303.61
GREASE TRAP VAULT #8004
RIM=5305.32
NW/SE INV 12" PIPE=5298.49
NE DROP INV 6" PIPE=5299.26
BUILDING FF=5306.45
BUILDING FACE
BUILDING FACE
LINE ABANDONED
PER VA STAFF
P
PP
UGEUGE
UGE
W
W W
W W
WW
W
W
W
W
W
W
W
W
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
W
W
UGE
UG
E
UGE
SD
SD
SD
SD
UGE
G
G G
G
U G
E
UGE
UGE
UGE
UGE
UG
E
UG
E
UG
E
UG
E
UG
E
U G
E
UGE
SS
E
E
E E
E
E
E
E
E E
E
E E
E
E
E
E
E E
5'
.4
3'
.7
9'
.2
9'
49.13'
5'
E
2.43'
E
E
E
E
21.08'
18.08'
19.29'
3'
5'
SDMH #8005
RIM=5304.02
NW/SE INV 12" PIPE=5298.49
NE DROP INV 6" PIPE=5299.26
SSMH #8123
RIM=5304.79
SSMH #8126
RIM=5304.53
INV 12" PIPE=5296.85
BUILDING FF=5303.85
BUILDING FACE
W
W
W
W
W
WW
W
W
W
SS
W
W
W
W
UGE
UGE
G
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
FO
SS
SS
SS
SS
SS
SS
SS
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
HH
SD
SD
SD
CWS
CWS
CWS
CWS
CWS
CWS
CWS
CWS
CWS
CWS
CWS
CWS
CWS
CWS
SS
W
W
W
W
W
W
G
UGE
UGE
3'
AP
PR
OX
CO
L.
H
OL
M
BE
RG
R
OA
D
.4
4'
.5
8'
AP
PR
OX
E
E
E
E
EE
E
E
E
E
15.76'
2.25'
4.50'
4.
2.
4.50'
2.25'
10'
55.12'
.2
8'
24'
.3
4'
.4
6'
E
E
E
E th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project NumberCONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. 62918 EXP. 12/31/2022
MECH ENGR REG. NO. 69943 EXP. 12/31/2022
ELEC ENGR REG. NO. 70271 EXP. 12/31/2022
STRUCTURAL / CIVIL ENGINEER
H2B, INC.
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(314) 436-9492
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
SPUR #: 1395.29
2/
/2
:3 6:
A
M
BID DOCUMENTS
REPLACE HOSPITAL (B107)
ELECTRICAL SERVICE
08/05/2022
649-18-105
NORTHERN ARIZONA VA HEALTH
CARE SYSTEM
500 AZ-89, PRESCOTT, AZ 86301
No. REVISION DESCRIPTION DATE
08/
02/
TOD J.
HENNING
57430
SCALE: 1" = 40'1 ENLARGED SITE DIMENSION PLAN
SCALE: 1" = 10'2 ENLARGED ENTRY DIMENSION PLAN
BENCHMARK: .
NOTES: .
LEGEND: .
HELD A CITY OF PRESCOTT PUBLISHED BENCHMARK:
MOL-03 NAVD(88) ELEVATION = 5349.12
FOUND CARRIAGE BOLT WITH 2" WASHER ON TOP OF CURB ON
N.W. CURB RETURN AT S.W. CORNER OF NORTH WASHINGTON
AVENUE AND MOELLER STREET.
EXISTING FIBER OPTIC LINEFO
EXISTING GAS LINEG
EXISTING FUEL LINEO
EXISTING SANITARY SEWERSS
EXISTING STORM DRAINSD
EXISTING TELEPHONE LINET
EXISTING UNDERGROUND ELECTRIC LINEUGE
EXISTING WATER LINEW
EXISTING CHILLED WATER SUPPLY LINECWS
SEE TOPOGRAPHIC SURVEY FOR EXISTING FEATURES LEGEND
NEW ELECTRICAL LINEE
CIVIL ENLARGED SITE & ENTRY
DIMENSION PLAN
DMH 8ALL
KEYED NOTES: .
SWPPP KEY NOTES:
SWPPP DEVICE (SEE NOTE 10)1
1. ALL SUBCONTRACTORS WILL BE EDUCATED TO
FOLLOW STORM WATER POLLUTION PREVENTION
REQUIREMENTS.
2. ANY LAND CLEARING, CONSTRUCTION,
DEVELOPMENT, OR OTHER ACTIVITIES INVOLVING
THE MOVEMENT OF EARTH SHALL BE IN
ACCORDANCE WITH THE SWPPP.
3. A SITE OPERATOR SHALL BE ON SITE ON ALL DAYS
WHERE CONSTRUCTION OR GRADING ACTIVITY
TAKES PLACE.
4. STRUCTURAL BMP's WILL BE INSPECTED AND
MAINTAINED AT LEAST EVERY 14 DAYS AND AFTER
ANY PRECIPITATION OR RUNOFF EVENT THAT
CAUSES SURFACE EROSION, SEDIMENT
TRANSPORT OR VEHICULAR TRACKING.5. SCRAPING AND SWEEPING OF STREETS, SIDEWALKS
AND…
This is the start of the file's text. The full file is on GovTribe.