Attachment - Drawings.pdf
PDF 22 MB Posted
- Attached to
- Z2DA--Replace Flooring in OR, PACU, and Special Procedures Federal contract opportunity
- Solicitation number
- 36C26124R0094
About this file
This document appears to be an attachment containing drawings related to a federal contract opportunity. The federal contract opportunity is for construction services to replace flooring in the Operating Room, Post-Anesthesia Care Unit, and Special Procedures areas of a Department of Veterans Affairs facility. The solicitation number is 36C26124R0094, and the proposal is due by December 19, 2024 at 11:00 AM PDT. Proposals should be submitted to david.rovner@va.gov and daniel.jhun@va.gov. The contracting agency is the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 21.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C26124R0094 0002.docx | DOCX document | |
| S04 Site Visit Sign-In 36C26124R0094.pdf | ||
| 36C26124R0094 0001.docx | DOCX document | |
| Attachment - REQUEST FOR INFORMATION RFI FORM.docx | DOCX document | |
| Attachment - PCRA 36C261-24-AP-4955.pdf | ||
| Attachment - Pre-Proposal Site Visit Information 36C26124R0094.pptx | PPTX presentation | |
| Attachment - VA DIRECTIVE 7715 EMR 02 FORM.pdf | ||
| Attachment - Wage Determination NV20240038 10182024.pdf | ||
| Attachment - Combined Specs 11-07-24.pdf | ||
| Attachment - Pricing Breakdown 36C26124R0094.docx | DOCX document | |
| Attachment - VAAR 852.219-75 VA NOTICE OF LIMITATIONS ON SUBCONTRACTING-CERTIFICATE.pdf | ||
| Attachment - Past Performance Questionaire PPQ Attachment B.pdf | ||
| Attachment - ICRA 593-19-310 unsigned draft.pdf | ||
| 36C26124R0094_1.docx | DOCX document |
Show all 14
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DRAWING LIST
VICINITY MAP
PROJECT TEAMBUILDING SUMMARY
PROJECT INFORMATION
GENERAL NOTES
PROJECT NAME: LAS VEGAS REPLACE FLOORING IN OR, PACU, AND SPECIAL PROCEDURES
PROJECT NUMBER: 593-19-310
PROJECT LOCATION: LAS VEGAS, NEVADA
PROJECT PURPOSE/USE: THIS PROJECT WILL REPLACE EXISTING FLOORING IN SEVERAL CRITICAL AREAS IN AND AROUND
THE OPERATING ROOMS AND CREATE A NEW OPENING BETWEEN THE PACU AND SPECIAL
PROCEDURE AREAS. THE END GOAL OF THE FLOORING PORTION OF THE PROJECT IS TO
PROVIDE COMPLIANT FLOORING MATERIALS FOR EACH AREA THAT ARE DURABLE, CLEANABLE,
AND VISUALLY APPEALING. THE PROJECT WILL INCLUDE REMOVAL OF PLUMBING FIXTURES,
WALL CLEAN OUTS, TOILET ACCESSORIES AND OTHER ITEMS THAT WILL BE REMOVED AND THEN
REINSTALLED AFTER THE FLOORING IS COMPLETED.
AREA OF WORK BUILDING AREA:
THIRD FLOOR
1. THESE DRAWINGS SHALL BE USED ONLY FOR THIS SPECIFIC PROJECT/SITE LOCATION. THESE DRAWINGS ARE A COMPOSITE SET OF CONTRACT DOCUMENTS AND SHALL NOT BE SEPARATED FOR DISTRIBUTION. THE GC SHALL REVIEW
ALL DRAWINGS AND PROVIDE/DISTRIBUTE THE ENTIRE SET TO EACH SUBCONTRACTOR.
2. THE GC SHALL VISIT THE SITE TO INSPECT EXISTING CONDITIONS AND VERIFY WORK BEING PERFORMED BEFORE
SUBMITTING COST QUOTATIONS FOR WORK.
3. NOTIFY THE VA CONTRACTING OFFICER'S REPRESENTATIVE PROMPTLY OF ANY ERRORS, OMISSIONS, INCONSISTENCIES, DISCREPANCIES AND CONFLICTS WITHIN THE CONTRACT DOCUMENTS AND ITS ASSOCIATED FIELD/PROJECT CONDITIONS
SO THAT A RESOLUTION CAN BE PROVIDED PRIOR TO CONTINUING WITH WORK.
4. DO NOT SCALE THE DRAWINGS. REQUEST ANY MISSING DIMENSIONS FROM THE ARCHITECT
5. ALL WORK PERFORMED SHALL BE IN STRICT COMPLIANCE WITH GOVERNING FEDERAL, STATE AND LOCAL BUILDING CODE REQUIREMENTS, SHALL BE EXECUTED IN ACCORDANCE WITH ACCEPTED INDUSTRY STANDARDS, AND SHALL CONFORM TO SPECIFIC REGULATIONS AS MANDATED BY THE OWNER, THE ARCHITECT, AND THE AUTHORITIES HAVING JURISDICTION.
THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ANY FEES ASSOCIATED WITH PROCURING SUCH PERMITS AND CERTIFICATES AND SHALL FURNISH COPIES OF PERMITS, INSPECTIONS, AND CERTIFICATES TO THE OWNER.
6. THE GENERAL CONTRACTOR SHALL COORDINATE ALL WORK TO MINIMIZE DISRUPTION OF ANY EXISTING TENANTS OR BUILDING OPERATIONS. THE GENERAL CONTRACTOR SHALL TAKE ADEQUATE PRECAUTIONS TO PROTECT BUILDING OCCUPANTS, MATERIALS, AND EXISTING CONSTRUCTION THROUGHOUT ALL PHASES OF CONSTRUCTION. DAMAGE TO EXISTING-TO-REMAIN CONSTRUCTION OR EQUIPMENT SHALL BE RESTORED TO ORIGINAL CONDITION AT THE
CONTRACTOR'S EXPENSE.
7. THE GENERAL CONTRACTOR SHALL REMOVE ALL TRASH AND DEBRIS FROM THE JOB SITE ON A DAILY BASIS.
8. ANY REQUESTS FOR SUBSTITUTIONS OF ANY SPECIFIED ITEM ARE TO BE SUBMITTED TO THE VA CONTRACTING OFFICER'S REPRESENTATIVE IN WRITING AND WILL BE CONSIDERED ONLY IF THE ALTERNATE PROPOSED IS PROVEN TO BE
ADVANTAGEOUS TO THE OWNER WITH RESPECT TO DELIVERY DATE, QUALITY, OR COST.
9. THE MEANS AND METHODS OF CONSTRUCTION, AND TEMPORARY STRUCTURES AND FACILITIES, ARE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. THE VA DOES NOT ASSUME ANY RESPONSIBILITY FOR THE CONTRACTOR'S MEANS AND
METHODS OR FOR TEMPORARY STRUCTURES.
10. DEMOLITION OF EXISTING STRUCTURES IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. THE CONTRACTOR SHALL
EMPLOY ENGINEERING EXPERTISE AS NEEDED TO ASSIST IN DEMOLITION.
11. JOB SITE SAFETY AND SECURITY ARE THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR. THE GENERAL CONTRACTOR SHALL CONSULT WITH LOCAL FIRE AUTHORITIES TO ASCERTAIN REQUIREMENTS FOR FIRE SUPPRESSION AND SAFETY DURING CONSTRUCTION. THE GENERAL CONTRACTOR IS SOLELY RESPONSIBLE FOR MEETING OSHA
REGULATIONS DURING CONSTRUCTION.
12. THE GENERAL CONTRACTOR IS SOLELY RESPONSIBLE FOR STORAGE AND PROTECTION OF BUILDING MATERIALS, AND INSTALLED CONSTRUCTION, FROM INCLEMENT WEATHER, THEFT, AND OTHER HAZARDS. THE GC SHALL FOLLOW ALL MANUFACTURER'S RECOMMENDATIONS FOR STORAGE OF MATERIALS. PARTIALLY COMPLETED WALLS SHALL BE COVERED TO PROTECT FROM WATER INTRUSION. DAMAGE, INCLUDING BUT NOT LIMITED TO MOLD, RESULTING FROM WATER INTRUSION DURING CONSTRUCTION SHALL BE REPAIRED AT THE GENERAL CONTRACTOR'S EXPENSE.
13. THE GENERAL CONTRACTOR SHALL ADHERE TO CONTRACTOR ACCESS LOCATED ON . ACCESS TO THE SURGICAL SUITE SHALL ONLY BE FROM 4:30 PM TO 6:00 AM AND ON WEEKENDS. OCCASIONALLY, EMERGENCY SURGERIES
WILL BE PERFORMED ON WEEKENDS. PLEASE COORDINATE ACCESS AND TIMING WITH THE COR.
14. PRIOR TO DEMOLITION OF FIXTURES OR OTHER FIXED EQUIPMENT IDENTIFY ANY MALFUNCTIONING FIXTURES OR EQUIPMENT. THE COR SHALL BE ADVISED OF ANY EXISTING MALFUNCTIONING FIXTURES PRIOR TO DEMOLITION. ANY FIXTURES OR EQUIPMENT THAT ARE NOT FUNCTIONING PROPERLY AFTER REINSTALLATION WILL BE THE RESPONSIBILITY
OF THE GENERAL CONTRACTOR.
15. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR THE INSTALLATION OF TEMPORARY FIRE EXTINGUISHERS AND SIGNAGE TO REDIRECT EXITING DURING THE CONSTRUCTION PERIOD TO ENSURE PATIENT AND STAFF SAFETY.
16. NOTIFY THE COR OF ANY POSSIBLE SHUTDOWNS OF MAJOR UTILITIES, I.E., ELECTRICAL, WATER, HVAC A MINIMUM OF THREE WEEKS PRIOR TO THE ANTICIPATED SHUTDOWN TO NOTIFY AND COORDINATE WITH VA STAFF.
17. THE GENERAL CONTRACTOR IS TO COORDINATE ALL PARKING AND DELIVERY PROVISIONS WITH THE VA PRIOR TO ANY
EXECUTION.
18. COR RESERVES THE RIGHT TO DIRECT THE GENERAL CONTRACTOR TO STOP WORK WHICH MAY IMPACT OPERABLE
AREAS OF THE MEDICAL CENTER.
30,816 GSF
AREA OF WORK
E. DEER SPRINGS WAY
N
P E
C O
S R
D
BRUCE WOODBURY BELTWAY
CLASS IV ICRA NOTES
DURING CONSTRUCTION
1. Isolate HVAC system in area where work is being done to prevent contamination of duct system.
2. Complete all critical barriers i.e. sheetrock, plywood, plastic, to seal area from non work area or implement control cube method (cart with plastic covering and sealed connection to work site with HEPA vacuum for vacuuming prior to exit) before construction begins.
3. Maintain negative air pressure within work site utilizing HEPA equipped air filtration units.
4. Seal holes, pipes, conduits, and punctures appropriately.
5. Construct anteroom and require all personnel to pass through this room so they can be vacuumed using a HEPA vacuum cleaner before leaving work site or they can wear cloth or paper coveralls that are removed each time they leave the work site. Anteroom to have walk-off mats at entry and whose surface is to be replaced as needed.
6. All personnel entering work site are required to wear shoe covers. Shoe covers must be changed each time the worker exits the work area.
7. Do not remove barriers from work area until completed project is inspected by the owner’s Safety Department and Infection Control Department and thoroughly cleaned by the owner’s Environmental Services Department.
UPON COMPLETION OF PROJECT
1. Remove barrier material carefully to minimize spreading of dirt and debris associated with construction.
2. Contain construction waste before transport in Tightly covered containers.
3. Cover transport receptacles or carts. Tape covering unless solid lid
4. Vacuum work area with HEPA filtered vacuums.
5. Wet mop area with disinfectant.
6. Remove isolation of HVAC system in areas where work is being performed.
/1 GC100
DEDUCTIVE ALTERNATES:
1) DELETE INSTALLATION OF FLOORING AT STAFF LOUNGE/DICTATION ROOM 3D244.
2) DELETE INSTALLATION OF FLOORING AT ANESTHESIA WORK ROOM 3D422.
3) DELETE INSTALLATION OF FLOORING AT CORRIDOR C3-66
Romanyk Consulting Focusing on what matters
VA FORM 08 - 6231
F
E
D
C
B
A
910 7 6 5 4 3 2 1
8910 7 6 5 4 3 2 1
U.S. Department of Veterans Affairs
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
U.S. Department of Veterans Affairs
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
Spinklered
FULLY SPRINKLERED
B
IM
/V
IS
N
L a s V e g a s R e p la c e
F lo o r
S p e c C lin ic s /L a s V e g a s R e p la c e F lo o r
S p e c C lin ic s
V
.r v t
/1
/2
:1
:2
A
M
VA PROJECT NUMBER - 593-19-310
REPLACE FLOORING IN OR, PACU, AND SPECIAL
PROCEDURES
100% CONSTRUCTION DOCUMENT SUBMISSION
MARCH 19, 2024
RCO IL
593-19-310
GI100
593 - NORTH LAS VEGAS, NV
MARCH 19, 2024
01-
SHEET INDEX & GENERAL INFORMATION 100% CONSTRUCTION
DOCUMENT SUBMISSION
REPLACE FLOORING IN OR, PACU,
AND SPECIAL PROCEDURES
COR:
Veterans Affairs Southern Nevada Healthcare System 6900 North Pecos Rd North Las Vegas, NV 89086
Marjorie Winemiller Marjorie.Winemiller@va.gov
702.791.9000 x18823
702.241.9729 cell
PROJECT ARCHITECT:
Romanyk Consulting Corp.
3308 Preston Road, Suite 350-164 Plano, Texas 75093
Rebecca Olson, AIA, ACHA, NCARB, LEED AP rebecca.olson@RomanykConsulting.com
855.424.3838 x302
602.430.1265 cell
MECHANICAL ENGINEER:
Romanyk Consulting Corp.
3308 Preston Road, Suite 350-164 Plano, Texas 75093
Arlo Wieczorek, PE Arlo.Wieczorek@RomanykConsulting.com
319.721.4986 cell
ELECTRICAL ENGINEER:
Romanyk Consulting Corp.
3308 Preston Road, Suite 350-164 Plano, Texas 75093
Yumei Wang, PE, PMP, LEED AP yumei.wang@RomanykConsulting.com
855.424.3838 x311
402.321.3766 cell
PLUMBING ENGINEER:
Romanyk Consulting Corp.
3308 Preston Road, Suite 350-164 Plano, Texas 75093
Arlo Wieczorek, PE Arlo.Wieczorek@RomanykConsulting.com
319.721.4986 cell
CONTRACTING OFFICER, CONSTRUCTION TEAM II:
Network Contracting Office (NCO 21) 10535 Hospital Way Mather, CA 95655
Daniel Jhun daniel.jhun@va.gov
916.923.4507
SHEET # SHEET TITLE
GENERAL
01-GI100 SHEET INDEX & GENERAL INFORMATION
01-GI101 ABBREVIATIONS & SYMBOLS
01-GI102 ADA INFORMATION
01-GI103 ICRA SHEET
01-GI200 SITE PLAN
01-GI201 THIRD LEVEL OVERALL LIFE SAFETY PLAN
01-GI202 THIRD LEVEL SCOPE OF WORK LIFE SAFETY PLAN
01-GC100 PHASING PLAN
ARCHITECTURAL
01-AD101 THIRD LEVEL OVERALL DEMOLITION PLAN
01-AD102 THIRD LEVEL AREA A DEMOLITION PLAN
01-AD103 THIRD LEVEL AREA B DEMOLITION PLAN
01-AE101 THIRD LEVEL OVERALL PLAN
01-AE102 THIRD LEVEL AREA A PLAN
01-AE103 THIRD LEVEL AREA B PLAN
01-AE200 ENLARGED TOILET PLANS AND ELEVATIONS
01-AE201 ENLARGED TOILET PLANS AND ELEVATIONS
01-AE202 ENLARGED TOILET PLANS AND ELEVATIONS
01-AE203 ENLARGED TOILET PLANS AND ELEVATIONS
01-AE204 ENLARGED PLANS AT OPENING
01-AE400 THIRD LEVEL INTERIOR ELEVATIONS
01-AE501 METAL STUD DETAILS
01-AF100 INTERIOR FINISH NOTES AND DETAILS
01-AF101 THIRD LEVEL OVERALL FINISH PLAN
01-AF102 THIRD LEVEL AREA A FINISH PLAN
01-AF103 THIRD LEVEL AREA B FINISH PLAN
SPRINKLER
01-F-100 FIRE SPRINKLER LEGEND, SCHEDULES AND ABBREVIATIONS
01-FD101 THIRD LEVEL OVERALL SPRINKLER DEMOLITION PLAN
01-FS101 THIRD LEVEL OVERALL SPRINKLER PLAN
PLUMBING
01-P-100 PLUMBING LEGEND, SCHEDULES AND ABBREVIATIONS
01-PD101 THIRD LEVEL OVERALL PLUMBING DEMOLITION PLAN
01-PP101 THIRD LEVEL OVERALL PLUMBING PLAN
MECHANICAL
01-M-100 MECHANICAL LEGEND, SCHEDULES AND ABBREVIATIONS
01-MD101 THIRD LEVEL OVERALL HVAC DEMOLITION PLAN
01-MH101 THIRD LEVEL OVERALL HVAC PLAN
ELECTRICAL
01-E-100 ELECTRICAL LEGEND, SCHEDULES AND ABBREVIATIONS
01-ED101 THIRD LEVEL OVERALL ELECTRICAL DEMOLITION PLAN
01-EP101 THIRD LEVEL OVERALL ELECTRICAL PLAN
Revisions: Date:
1i
0 GRID / COLUMN LINE DESIGNATOR
EQUIPMENT NUMBER
DOOR NUMBER
Ga5xFB1
WALL TYPE
WINDOW TYPE
ROOM NAME
ROOM NAME / NUMBER
REVISION TAG
PLAN NORTH
NORTH ARROW WITH TRUE
NORTH INDICATION
EGRESS ROUTE ID AND
SECTION LENGTH
ROOM
ROOM OCCUPANCY
150 SF
EGRESS : EGRESS ID
Egress Length
ROOM OCCUPANCY & AREA
ELEVATION NUMBER
SECTION
INTERIOR ELEVATION
ENLARGEMENT,
DETAIL
SPOT ELEVATION
Name Elevation
FLOOR LEVEL &
NAME
PLATE NUMBER WHERE
SECTION/DETAIL IS DRAWN
PLATE NUMBER WHERE
SECTION/DETAIL IS DRAWN
PLATE NUMBER WHERE
SECTION/DETAIL IS DRAWN
SHEET KEYNOTE
A101
SIM
EXTERIOR ELEVATION
A-101
PLATE NUMBER WHERE
SECTION/DETAIL IS DRAWN
A101
A101
ANNOTATION DRAWING SYMBOLS
INDEX OF DRAWINGS
202-A101
DISCIPLINE:
G - GENERAL
A - ARCHITECTURE
I - INTERIORS
F- FIRE PROTECTION
P - PLUMBING
M - MECHANICAL
E - ELECTRICAL
T - TELECOM
V - VENTILATION
SHEET TYPE
DESIGNATOR
BUILDING NUMBER
SHEET NUMBER
WITHIN SERIES
ARCHITECTURAL SYMBOLS
LEGEND
CONCRETE/ PRECAST
CONCRETE
SOIL
SAND, EIFS FINISH COAT,
OR CEMENT PLASTER
BRICK
CMU
STONE
FIBERGLASS BATT
INSULATION
EXPANDED POLYSTYRENE
RIGID INSULATION
EXTRUDED POLYSTYRENE
RIGID INSULATION
POLYISOCYANURATE RIGID
INSULATION
GYPSUM BOARD
EXTERIOR GYPSUM
SHEATHING
EXTERIOR CEMENT
BOARD
COATED GLASS MAT
WATER RESISTANT
GYP BD
PLYWOOD
COVER BOARD
MATERIALS
CEILING SYMBOLS
MECHANICAL SUPPLY DIFFUSER
MECHANICAL RETURN GRILLE
MECHANICAL EXHAUST GRILLE
24" X 24" ACOUSTICAL CEILING
PANEL AND GRID
GYPSUM BOARD CEILING OR
SOFFIT
2' x 2' LED FLUORESCENT
FIXTURE - EMERGENCY NIGHT
LIGHT
RECESSED CAN DOWNLIGHT
CEILING ELEVATION A.F.F.X'-X"
EXIT SIGN
LED LIGHT
1' x 4' LED FLUORESCENT
FIXTURE
2' x 4' LED FLUORESCENT
FIXTURE
INDUSTRIAL LUMINAIRE
EMERGENCY LIGHT
2' x 2' LED FLUORESCENT
FIXTURE
OC
NURSE CALL DOME LIGHT WALL
MOUNTED
A
FIRE ALARM AUDIO/VISUAL
NOTIFICATION DEVICE-CEILING
MOUNTED.
CAM
LS
OCCUPANCY SENSOR
A1 A3
DAYLIGHT LEVEL SENSOR
CLOSED CIRCUIT CAMERA (CCTV)
CEILING MOUNTED
N
S SPEAKER
CLOSED CIRCUIT CAMERA (CCTV)CAM
VC VACANCY SENSOR
WAP CEILING INFORMATION OUTLET
FIRE ALARM VISUAL NOTIFICATION
DEVICE - WALL MOUNTED
V1
WALL CONTROL STATIONSW
NURSE CALL STATIONN
SMOKE,FIRE/SMOKE
DAMPER CONTROLLER
ARD
FIRE ALARM MANUAL PULL
STATION
F
FIRE ALARM SMOKE,
SMOKE DAMPER
SD
SD FIRE ALARM DUCT SMOKE
DETECTOR
D DIMMER LED
A FIRE ALARM AUDIO/VISUAL
NOTIFICATION DEVICE- WALL
MOUNTED.
A1 A3
S SWITCH
{LD}
{LS}
LIGHT DIMMER
LIGHT SENSOR
ARCHITECTURAL DRAWING ABBREVIATIONS
A ---------------------
A LABEL CLASS A DOOR
A/C AIR CONDITION
A/C UNIT AIR CONDITIONING UNIT
A/E ARCHITECT/ENGINEER
AB ANCHOR BOLT
ACC ACCESSIBLE
ACS AUTOMATIC CONTROL SYSTEM
ACS DR ACCESS DOOR
ACS PNL ACCESS PANEL
ACT ACOUSTICAL CEILING TILE
ADA AMERICANS WITH DISABILITIES ACT
ADMIN ADMINISTRATION
AFC ABOVE FINISHED COUNTER
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AFS ABOVE FINISHED SLAB
AGGR AGGREGATE
AHU AIR HANDLING UNIT
AIB AIR INFILTRATION BARRIER
ALT ALTERNATE
ALG ALUMINUM AND GLASS
AL ALUMINUM
ALUM ALUMINUM
ANOD ANODIZE
APC ACOUSTICAL PANEL CEILING
APPROX APPROXIMATE
AR AS REQUIRED
ARCH ARCHITECT
ASC ABOVE SUSPENDED CEILING
ASSY ASSEMBLY
ATC ACOUSTICAL TILE CEILING
AVG AVERAGE
AW ARCHITECTURAL WOODWORK
AWT ACOUSTICAL WALL TREATMENT
B ---------------------
B LABEL CLASS B DOOR
BALC BALCONY
BB BASEBOARD
BC BOOKCASE
BD BOARD
BDRY BOUNDARY
BFF BELOW FINISH FLOOR
BHMA BUILDER'S HARDWARE MANUFACTURER'S ASSOCIATION
BLDG BUILDING
BLKG BLOCKING
BLT IN BUILT-IN
BN BULLNOSE
BOS BOTTOM OF STEEL
BOT BOTTOM
BP BUILDING PAPER
BRKT BRACKET
BSMT BASEMENT
BTWN BETWEEN
BUR BUILT-UP ROOFING
C ---------------------
C CONC CAST CONCRETE
C LABEL CLASS C DOOR
CAB CABINET
CATW CATWALK
CAV CAVITY
CBB CEMENTITIOUS (BACKER) BOARD
CD CONSTRUCTION DOCUMENTS
CDW CHILLED DRINKING WATER
CEM PLAS CEMENT PLASTER
CER CERAMIC
CF CONTRACTOR FURNISHED
CF/CI CONTRACTOR FURNISHED/CONTRACTOR INSTALLED
CFE CONTRACTOR FURNISHED EQUIPMENT
CFLG COUNTERFLASHING
CFM CUBIC FEET PER MINUTE
CFMF COLD-FORMED METAL FRAMING
CFS CUBIC FEET PER SECOND
CG CORNER GUARD
CI CAST IRON
CIP CAST-IN-PLACE
CJ CONTROL JOINT
CL CENTER LINE
CLG CEILING
CLG DIFF CEILING DIFFUSER
CLG HT CEILING HEIGHT
CLL COLUMN LINE
CLO CLOSET
CLR COLOR
CLRM CLASSROOM
CMU CONCRETE MASONRY UNIT
CNDS CONDENSATE
CDR CARD READER
CO CLEANOUT
COL COLUMN
COMM COMMUNICATION
CONC CONCRETE
CONC FLR CONCRETE FLOOR
CONF CONFERENCE
CONT CONTINUE
COORD COORDINATE
CORR CORRIDOR
CP CONCRETE PIPE
CPT CARPET
CR CONTROL ROOM
CS CAST STONE
CSWK CASEWORK
CT CERAMIC TILE
CTB CERAMIC TILE BASE
CTF CERAMIC TILE FLOOR
CTR CENTER
CU FT CUBIC FEET
CW CASEMENT WINDOW
D ---------------------
D DEPTH
D LABEL CLASS D DOOR
DBL DOUBLE
DEMO DEMOLITION
DEPT DEPARTMENT
DET DETAIL
DIA DIAMETER
DIR DIRECTION
DIST DISTANCE
DOC DOCUMENT
DR DOOR
DS DOWNSPOUT
E ---------------------
E LABEL CLASS E DOOR
EA EACH
EF EACH FACE
EIFS EXTERIOR INSULATION AND FINISH SYSTEM
EJ EXPANSION JOINT
ES EACH SIDE
EL ELEVATION
ELEC ELECTRICAL
ELEV ELEVATOR
ELEV EQ ELEVATOR EQUIPMENT
ENTR ENTRANCE
EPS EXPANDED POLYSTYRENE BOARD (INSULATION)
EQ EQUAL
EWC ELECTRIC WATER COOLER
EXP EXPOSED
EXT EXTERIOR
EXT EXTINGUISHER
EXT GR EXTERIOR GRADE
F ---------------------
FA FIRE ALARM
FAAP FIRE ALARM ANNUNCIATOR PANEL
FAS BD FASCIA BOARD
FC BRK FACE BRICK
FCO FLOOR CLEANOUT
FD FLOOR DRAIN
FDTN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FED FEDERAL
FF FINISH FACE
FF EL FINISH FLOOR ELEVATION
FF INSUL FOIL BACKED INSULATION
FGL FIBERGLASS
FH FIRE HOSE
FHP FULL HEIGHT PARTITION
FIN FINISH
FIN BS FINISH BOTH SIDES
FIN FLR FINISH FLOOR
FIN GR FINISH GRADE
FIXT FIXTURE
FLDG FOLDING
FLEX FLEXIBLE
FLG FLOORING
FLMT FLUSH MOUNT
FLR FLOOR
FM FACTORY MUTUAL
FOC FACE OF CONCRETE
FOM FACE OF MASONRY
FR FIRE RESISTANT
FRG FIBER REINFORCED GYPSUM
FRMG FRAMING
FRP FIBERGLASS REINFORCED PLASTIC
FRTW FIRE RETARDANT TREATED WOOD
FS FEDERAL SPECIFICATION
FSTNR FASTENER
FT FEET
FTG FOOTING
FWC FABRIC WALLCOVERING
G ---------------------
G NATURAL GAS
GALV GALVANIZED
GB GRAB BAR
GFCI GOVERNMENT FURNISHED CONTRACTOR INSTALLED
GFGI GOVERNMENT FURNISHED INSTALLED BY GOVERNMENT
GFRG GLASS-FIBER-REINFORCED GYPSUM
GLZ GLAZING
GR FL GROUND FLOOR
GSF GROSS SQUARE FEET
GUT GUTTER
GYP BD GYPSUM BOARD
GYP PLAS GYPSUM PLASTER
H ---------------------
HAC HOUSE AID KEEPING CLOSET
HB HOSE BIBB
HDPE HIGH DENSITY POLYETHYLENE
HDW HARDWARE
HDWD HARDWOOD
HEPA HIGH EFFICIENCY PARTICULATE AIR (FILTER)
HM HOLLOW METAL
HMD HOLLOW METAL DOOR
HMF HOLLOW METAL FRAME
HORIZ HORIZONTAL
HR HOUR
HT HEIGHT
HVAC HEATING, VENTILATION, AND AIR CONDITIONING
HYDR HYDRAULIC
I ---------------------
IBC INTERNATIONAL BUILDING CODE
INSUL INSULATION
INT INTERIOR
ILO IN LIEU OF
ISO ISOLATION
J ---------------------
JAN JANITOR
K ---------------------
KPD KEYPAD
KIT KITCHEN
KPL KICKPLATE
L ---------------------
LAM LAMINATE
LAV LAVATORY
LBR LUMBER
LBS POUND
LDG LANDING
LED LIGHT EMITTING DIODE
LF LINEAR FEET (FOOT)
LIB LIBRARY
LIN LINEAR
LKR LOCKER
LOC LOCATION
LT LIGHT
LVDR LOUVER DOOR
LVR LOUVER
M ---------------------
MACH RM MACHINE ROOM
MATL MATERIAL
MAX MAXIMUM
MC MOISTURE CONTENT
MD METAL DECK
MECH MECHANICAL
MECH RM MECHANICAL ROOM
MEMB MEMBRANE
MF MILL FINISH
MFR MANUFACTURER
MID MIDDLE
MIL STD MILITARY STANDARD
MIN MINIMUM, MINUTE
MIRR MIRROR
MISC MISCELLANEOUS
MLDG MOLDING (MOULDING)
MO MASONRY OPENING
MOD MODIFY
MB MOISTURE BARRIER
MTG MOUNTING
MTL METAL
MVBL MOVABLE
MWP MEMBRANE WATERPROOFING
N ---------------------
N NORTH
NA NOT APPLICABLE
NFPA NATIONAL FIRE PROTECTION ASSOCIATION
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NP NO PAINT
NRC NOISE REDUCTION COEFFICIENT
NTS NOT TO SCALE
O -------------------
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER
OFD OVERFLOW DRAIN
OFF OFFICE
OGL OBSCURE GLASS
OPH OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
OPQ OPAQUE
OWSJ OPEN WEB STEEL JOIST
OPR OPERABLE
ORD OVERFLOW ROOF DRAIN
ORIG ORIGINAL
P --------------------
PA PUBLIC ADDRESS
PAR PARAPET
PAT PATTERN
PB PULL BOX
PBD PARTICLEBOARD
PCC PRECAST CONCRETE
PCF POUNDS PER CUBIC FOOT
PCT PERCENT
PERF PERFORATED
PERIM PERIMETER
PH PHASE
PIL PILASTER
PL PROPERTY LINE
PL GL PLATE GLASS
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLBG PLUMBING
PLG PILING
PLYWD PLYWOOD
PNL PANEL
PP PL PUSH/PULL PLATE
PR PAIR
PRCST PRECAST
PRKG PARKING
PS CONC PRESTRESSED CONCRETE
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PRESSURE TREATED
PTD PAPER TOWEL DISPENSER
PTDR PAPER TOWEL DISPENSER AND RECEPTACLE
PTN PARTITION
PWR POWER
Q --------------------
QT QUARRY TILE
QTY QUANTITY
R --------------------
RB RESILIENT BASE
RBM REINFORCED BRICK MASONRY
RBR RUBBER
RC REINFORCED CONCRETE
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
RDG INS RIGID INSULATION, SOLID
REC RECESSED
REC ROOM RECREATION ROOM
REF REFERENCE
REM REMOVABLE
REP REPAIR
REPL REPLACE
REQ REQUIRE
REQD REQUIRED
RESIL RESILIENT
REST RESTROOM
RF RESILIENT FLOORING
RFG ROOFING
RH ROOF HATCH
RHR RIGHT HAND REVERSE
RL ROOF LEADER
RLG RAILING
RM ROOM
RO ROUGH OPENING
RSD ROLLING STEEL DOOR
RV ROOF VENT
RVL REVEAL
S --------------------
SB SPLASH BLOCK
SCHED SCHEDULE
SD SMOKE DETECTOR
SF SQUARE FOOT (FEET)
SFTWD SOFTWOOD
SGL SINGLE
SHT MTL FLASH SHEET METAL (FLASHING)
SHTHG SHEATHING
SHWR SHOWER
SHV SHELVING
SIM SIMILAR
SJ SCORED JOINT
SKLT SKYLIGHT
SLNT SEALANT
SMK SMOKE
SMLS SEAMLESS
SP EL SPOT ELEVATION
SPEC SPECIFICATION
SQ SQUARE
SQ IN SQUARE INCH
SQ YD SQUARE YARD
SST STAINLESS STEEL
ST STAIRS
STD STANDARD
STL JST STEEL JOIST
STL RF DK STEEL ROOF DECK
STOR STORAGE
STR STRINGERS
STRB/HRN STROBE/HORN
SUB FL SUBFLOOR
SV SHEET VINYL
SW SIDEWALK
T --------------------
T TREAD
T/S TUB/SHOWER
TC TERRA COTTA
TD TRENCH DRAIN
TEL TELEPHONE
TEMP TEMPORARY
TER TERRAZZO
TFF TOP OF FINISH FLOOR
THK THICKNESS
TK BD TACKBOARD
TMPD GL TEMPERED GLASS
TN TRUE NORTH
TOF TOP OF FOOTING
TOM TOP OF MASONRY
TOP TOP OF PARAPET
TOPO TOPOGRAPHY
TOS TOP OF SLAB
TRANS TRANSOM
TRTD TREATED
TV TELEVISION
SEE OTHER DISCIPLINES FOR
ADDITIONAL ABREVIATIONS
NOTE: NOT ALL MAY BE USED
ARCHITECTURAL SYMBOLS
NOTE:
KEYNOTES RESIDE ON A 'MASTER' SCHEDULE FOR DEMOLITION AND NEW WORK.
THIS IS FURTHER BROKEN DOWN BY SHEET. ALL KEYNOTES MAY NOT PERTAIN
TO EACH SHEET, THEREFORE:
• ONLY KEYNOTES ON THE SHEET WILL BE LISTED IN THE KEYNOTE LEGEND.
• KEYNOTE MAY NOT BEGIN AT "1" FOR A SHEET.
• KEYNOTES MAY SKIP NUMBERS, BUT WILL LIST IN NUMERICAL ORDER FOR
THAT SHEET.
KEYNOTE NUMBER (ON SHEET)
KEYNOTE DESCRIPTION
THIS IS AN EXAMPLE OF WHAT KEYNOTE 3 COULD BE. IT
MIGHT BE THE FIRST KEYNOTE ON A SHEET. IT MIGHT ALSO
SHOW ON MULTIPLE SHEETS.
THIS IS AN EXAMPLE OF WHAT KEYNOTE 7 COULD BE. IT
MIGHT ALSO SHOW ON MULTIPLE SHEETS.
THIS IS AN EXAMPLE OF WHAT KEYNOTE 22 COULD BE. IT
MIGHT ALSO SHOW ON MULTIPLE SHEETS.
KEYNOTE DESIGNATIONS
KEYNOTES
KEYNOTE SYMBOL ON SHEET
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
U.S. Department of Veterans Affairs
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
Spinklered
FULLY SPRINKLERED
B
IM
/V
IS
N
L a s V e g a s R e p la c e
F lo o r
S p e c C lin ic s /L a s V e g a s R e p la c e F lo o r
S p e c C lin ic s
V
.r v t
/1
/2
:1
:3
A
M
RCO IL
593-19-310
GI101
593 - NORTH LAS VEGAS, NV
MARCH 19, 2024
01-
ABBREVIATIONS & SYMBOLS 100% CONSTRUCTION
DOCUMENT SUBMISSION
REPLACE FLOORING IN OR, PACU,
AND SPECIAL PROCEDURES
ACCESSIBLE SIGNAGE REQS
CHARACTER HEIGHTS
TOILET ACCESSORY LEGEND
NOTES
CHARACTER PROPORTIONS:
LETTERS AND NUMBERS ON SIGNS SHALL HAVE A WIDTH-TO-HEIGHT RATIO
BETWEEN 3:5 AND 1:1 AND A STROKE-WIDTH-TO-HEIGHT RATIO BETWEEN 1:5 AND
1:10, UTILIZING AN UPPER CASE 'X' FOR MEASUREMENT.
CHARACTER HEIGHT:
SEE LETTER AND NUMBER HEIGHT CHART BELOW
*EXCEPTION: CHARACTER HEIGHT SHALL BE 5/8" HIGH MINIMUM FOR BUILDING
DIRECTORIES.
PICTOGRAMS:
WHERE PICTOGRAMS ARE REQUIRED, THEY SHALL HAVE A 6" MINIMUM SIZE
MEASURED AT THE BORDER. WHERE TEXT DESCRIPTORS FOR PICTOGRAMS ARE
REQUIRED, THEY SHALL COMPLY WITH THE TACTILE CHARACTER PROVISIONS OF
RAISED CHARACTERS AND SYMBOLS, BRAILLE, AND LOCATION OF TACTILE
SIGNAGE PORTIONS BELOW.
FINISH AND CONTRAST:
THE CHARACTERS, SYMBOLS AND BACKGROUND OF SIGNS SHALL BE EGGSHELL,
MATTE, OR OTHER NON-GLARE FINISH. CHARACTERS AND BRAILLE, AND LOCATION
OF TACTILE SIGNAGE PORTIONS BELOW. LIGHT BACKGROUND.
RAISED CHARACTERS AND SYMBOLS:
CHARACTERS AND SYMBOLS ON TACTILE SIGNS SHALL BE RAISED 1/32" MINIMUM.
RAISED CHARACTERS AND SYMBOLS SHALL BE IN UPPERCASE CHARACTERS.
RAISED CHARACTERS AND SYMBOLS SHALL BE 5/8" HIGH MINIMUM, AND 2"
MAXIMUM. RAISED CHARACTERS AND SYMBOLS SHALL BE ACCOMPANIED BY
BRAILLE IN ACCORDANCE WITH THE PROVISIONS OUTLINED BELOW.
BRAILLE:
BRAILLE SHALL BE SEPARATED 1/2" MINIMUM FROM THE CORRESPONDING RAISED
CHARACTERS OR SYMBOLS. BRAILLE PROVIDED IN ACCORDANCE WITH THE
REQUIREMENTS FOR ELEVATOR CONTROLS SHALL BE PLACED 3/16" MINIMUM BELOW
THE CORRESPONDING CHARACTERS OR SYMBOLS. BRAILLE SHALL BE GRADE II AND
SHALL CONFORM TO SPECIFICATION #800, NATIONAL LIBRARY SERVICE, LIBRARY OF
CONGRESS.
LOCATION OF TACTILE SIGNAGE:
TACTILE SIGNAGE SHALL BE LOCATED ALONGSIDE THE DOOR ON THE LATCH SIDE
AND SHALL BE MOUNTED AT 60" ABOVE THE ADJACENT FINISHED FLOOR TO THE
CENTERLINE OF THE SIGN. IN LOCATIONS HAVING DOUBLE DOORS, TACTILE SIGNS
SHALL BE MOUNTED TO THE RIGHT OF THE RIGHT HAND DOOR. WHERE THERE IS
NO WALL SPACE ON THE LATCH SIDE OF THE DOOR, INCLUDING DOUBLE LEAF
DOORS, SIGNS SHALL BE RIGHT HAND DOOR. WHERE THERE IS NO WALL SPACE
ON THE LATCH SIDE OF THE DOOR, INCLUDING DOUBLE LEAF DOORS, SIGNS SHALL
BE PLACED ON THE NEAREST ADJACENT WALL.
GENERAL NOTES:
ANY ADDITIONAL TEXT REQUIRED DUE TO LOCAL ORDINANCES (FINES FOR
PARKING IN ACCESSIBLE SPACES, ETC.) SHALL COMPLY WITH THE SIGNAGE
REQUIREMENTS ABOVE.
ALL INTERIOR SIGNAGE WITHIN THE ASC SHALL CONFORM TO THE REQUIREMENTS
OF ADA 2010 AND ANY OTHER STATE OR LOCAL APPLICABLE CODES.
HEIGHT ABOVE FLOOR/ GROUND: MIN. CHARACTER HEIGHT:
GREATER THAN 80" (6'-8") AFF 3"
GREATER THAN 60" (5'-0") AFF BUT LESS THAN 80" (6'-8") AFF 2"
GREATER THAN 48" (4'-0") AFF BUT LESS THAN 60" (5'-0") AFF 1"
A FLOOR MOUNTED TOILET (CFCI)
GB42 42" - GRAB BAR (BOX FURNISHED & INSTALLED)
GB36 36" - GRAB BAR (BOX FURNISHED & INSTALLED)
GB18 18" - GRAB BAR (VERTICAL) (BOX FURNISHED &
INSTALLED)
E MIRROR (BOX FURNISHED & INSTALLED)
F TOILET PAPER DISPENSER (OFCI)
G ROBE HOOK (CFCI)
H SOAP DISPENSER (OFCI)
H PAPER TOWEL DISPENSER (OFCI)
J SANITARY NAPKIN DISPOSAL (CFCI)
O BABY CHANGING TABLE (CFCI)
P WALL MOUNTED SINK (BOX FURNISHED &
INSTALLED)
U SURFACE MTD TOILET SEAT COVER DISPENSER
1. SEE SPECIFICATIONS FOR MANUFACTURERS INFORMATION ON ALL TOILET
ACCESSORIES.
2. ALL SOAP DISPENSERS, PAPER TOWEL DISPENSERS, TOILET PAPER
DISPENSERS & HAND SANITIZER DISPENSERS TO BE OWNER FURNISHED AND
CONTRACTOR INSTALLED. LOCATIONS SHOWN FOR FACILITY.
3. FOR ALL TOILET ROOMS, REFER TO BOX VENDOR DRAWINGS FOR PARTITION
TYPES & DETAILS AND BLOCKING REQUIREMENTS FOR TOILET ACCESSORIES.
4. ALL TOILET LOCATIONS, WHETHER NOTED OR NOT, SHALL BE PROVIDED WITH
THE FOLLOWING UNLESS OTHERWISE NOTED:
a) ONE MIRROR
b) ONE TOILET PAPER DISPENSER
c) ONE ROBE HOOK - MOUNTED BEHIND STALL DOORS.
A D
A
T O
H A
N D
L E
MIRROR SOAP DISPENSER PAPER
TOWEL
DISPENSER
TOILET PAPER
DISPENSER
TOILET
PAPER
HOLDER
SANITARY
NAPKIN
DISPOSAL
MIN
1' - 3"
LAVATORY
M
IN
INSULATE EXPOSED
PIPING WITH WHITE
PLASTIC PRE-FITTED
INSULATION
M A
X
MEASURE
TO BOTTOM
OF REFLECTIVE
SURFACE
D
IS
P E
N S
E R
M A
X O
P E
R A
B L E
D
IS
P E
N S
E R
M
A X
T O
O P
E R
A B
L E
M A
X
M
IN
M
IN
FIRE
EXTINGUISHERS
AND CABINETS
7-PEG
COAT RACK
2' - 0"
"MIN
8"
MIN
11"
KNEE AND TOE
CLEARANCES
E
E
SEALANT
PROVIDE ADA
COMPLIANT FAUCET
WITH WRIST BLADE
CONTROLS
M A
X
5" MAX 15" MAX
ACCESS HGT. D.F.
SPOUT LOCATION
M
IN
SPOUT
HEIGHT
STANDING AND
ACCESSIBLE DRINKING
FOUNTAINS
FRONT SIDE
PLAN
ALUM. SEMI-RECESSED CAB.
W/ FULL CLEAR ACRYLIC DOOR
10 LBS
ABC TYPE
BABY CHANGING
TABLE
M A
X
/2
ROBE
HOOK
M A
X
"FIRE EXTINGUISHER" IN
RED LETTERS
G
F
F
(ALT)H
J
C
N O O
P
P
M
IN9
MIN
11"
M
IN
8"
25" MAX
30x48
CLEAR
SPACE
U
M A
X
TOILET
SEAT COVER
DISPENSER
SIGNAGE
(12" BELOW CEILING)
2"
HANDRAIL
PER NFPA 10
PTD (OF/OI)
PUBLIC TLTS
ONLY
SEMI-
RECESSED
WASTE RECP.
S P
O U
T H
G T
S T
A N
D
IN
G H
E
IG
H T
D .F
A C
C E
S S
H
E
IG
H T
D .F
M A
X
NOTE: PROVIDE CANE
DETECTABLE APRON AT
THE STANDING HEIGHT
UNIT
MIN
3' - 6"
MAX
1' - 0"
WATER CLOSET
SIDE WALL
1 1/4" MIN., 2" MAX DIA.
GRAB BAR WITH 1 1/2"
GAP FROM WALL
WATER CLOSET
BACK WALL
TP DISPENSER
MOUNTING AREA
1' - 6"
T .O
G
.B
/2
4' - 6" MIN
MIN
1' - 0"
MIN
2' - 0"
FLUSH CONTROLS
ON OPEN SIDE
M
IN
GB42
GB36
A
A
3' - 4"
/2
GB18
U
CENTER ON
GRAB BAR END
NOTE: GRAB BARS
SHALL BE 33" - 36" TO
TOP OF BAR
3' - 0"
NOTE: INFORMATION USED FOR MOUNTING OF EXISTING PLUMBING FIXTURES AND TOILET ACCESSORIES.
6"
6"
8"
MEN WOMEN
NO SMOKING
T
O F
IN
IS
H E
D F
L O
O R
F
IN
IS
H
E D
F L O
O R
T O
T O
F
IN
IS
H
E D
F L O
O R
PROPORTIONS OF THE INTERNATIONAL
SYMBOL OF ACCESSIBILITY
INTERIOR SIGNAGE
DOOR FRAME
LATCH SIDE OF
DOOR PANEL
TO TOP OF SIGN
GENERAL NOTES:
PROVIDE INTERIOR SIGNAGE FOR EVERY DOOR/ROOM UNLESS NOTED
OTHERWISE (REFER TO FINISH DRAWINGS).
ALL FINAL ROOM NAMES SHALL BE APPROVED BY ARCHITECT/OWNER PRIOR
TO SIGN FABRIACATION.
AT LOCATIONS WHERE THERE ISN'T AVAILABLE WALL SPACE TO INSTALL THE
INTERIOR SIGNAGE AS INDICATED, OBTAIN ARCHITECT'S INSTRUCTION PRIOR
TO INSTALLATION.
AT LOCATIONS WHERE THERE ISN'T AVAILABLE WALL SPACE, BUT AVAILABLE
WINDOW SPACE, ADHERE INTERIOR SIGNAGE WITH DOUBLE SIDED TAPE TO
PROVIDE A PERMANENT INSTALLATION. PROVIDE A BLANK PANEL OF THE
SAME COLOR, SIZE, AND MATERIAL FOR THE BACK SIDE OF THE SIGN TO BE
INSTALLED ON THE GLASS.
1.
2.
3.
4.
NTS
TOILET ACCESSORY MOUNTING HEIGHTS
NTS
ACCESSIBLE SIGNAGE DIAGRAMS
NTS
GENERAL - SIGNAGE
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
U.S. Department of Veterans Affairs
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
Spinklered
FULLY SPRINKLERED
B
IM
/V
IS
N
L a s V e g a s R e p la c e
F lo o r
S p e c C lin ic s /L a s V e g a s R e p la c e F lo o r
S p e c C lin ic s
V
.r v t
/1
/2
:1
:3
A
M
RCO IL
593-19-310
GI102
593 - NORTH LAS VEGAS, NV
MARCH 19, 2024
01-
ADA INFORMATION 100% CONSTRUCTION
DOCUMENT SUBMISSION
REPLACE FLOORING IN OR, PACU,
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
U.S. Department of Veterans Affairs
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
Spinklered
FULLY SPRINKLERED
B
IM
/V
IS
N
L a s V e g a s R e p la c e
F lo o r
S p e c C lin ic s /L a s V e g a s R e p la c e F lo o r
S p e c C lin ic s
V
.r v t
/1
/2
:1
:3
A
M
RCO IL
593-19-310
GI103
593 - NORTH LAS VEGAS, NV
MARCH 19, 2024
01-
ICRA SHEET 100% CONSTRUCTION
DOCUMENT SUBMISSION
REPLACE FLOORING IN OR, PACU,
D
Y
H
D
Y
H
V A N
V A N
V A N
V A N
V A N
V A N
V A N
V A N
V A N
V A N
V A N
V A N
V A N
V A N
V A N
V A N
V A N
V A N
V A N
V A N
V A N
V A N
V A N
V A N
V A N
V A N
V A N
V A N
VAN
VAN
PARKING LOT
D
PARKING LOT
CPARKING LOT
B
PARKING LOT
A
PARKING LOT
F
PARKING LOT
E
GOV
PARKING LOT
G
PARKING LOT
H
PARKING LOT
J
PARKING LOT
I
VAN
VAN
VAN
BLDG
#1
BLDG
#5 BLDG
#2
BLDG
#3
BLDG
#6
BLDG
#4
EAST DEER SPRINGS WAY
HOSPITAL
ADMINISTRATION
EMERGENCY
DEPARTMENT
ENERGY
PLANT
GENERATORS
WATER
TANKS
(4 Typ)
WAREHOUSE
HOSPITAL
AUDITORIUM
EMERGENCY
MANAGEMENT &
RESIDENT ENGINEER
BLDG
BLDG
#7 EDUCATION
SOLAR FARM (1.8
MW)
FISHER
HOUSE
BLDG
#8
MAIN
HOSPITAL
BLDG
#9
MENTAL HEALTH
CLINIC
EMERGENCY
MANAGEMENT
YARD
SPECIALTY
CLINICS
215 BELTWAY
EM
ERGENCY D
EPT
PARKIN
G
VAN
VAN
VAN
VAN
VAN
VAN
26HC
14HC
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
AA
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A A
A
A A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
LEGEND
HAUL ROUTE
LAYDOWN AREA
LOADING DOCK
CONTRACTOR ACCESS TO
SITE
GENERAL PROJECT
LOCATION
ACCESS ROUTE TO LOADING
DOCK
STAGING
AREA
LOADING
DOCK
3RD FLOOR
PROJECT AREA
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
U.S. Department of Veterans Affairs
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
Spinklered
NORTH
FULLY SPRINKLERED
B
IM
/V
IS
N
L a s V e g a s R e p la c e
F lo o r
S p e c C lin ic s /L a s V e g a s R e p la c e F lo o r
S p e c C lin ic s
V
.r v t
/1
/2
:2
:3
A
M
RCO IL
593-19-310
GI200
593 - NORTH LAS VEGAS, NV
MARCH 19, 2024
01-
SITE PLAN 100% CONSTRUCTION
DOCUMENT SUBMISSION
REPLACE FLOORING IN OR, PACU,
AND SPECIAL PROCEDURES
NTS
SITE PLAN
LIFE SAFETY NOTESKEY NOTES CODE SUMMARY
KEY PLAN
MECHANICAL SCREEN
TYPICAL
EQUIPMENT PAD - ELEVATION
MECHANICAL SCREEN
TYPICAL
EQUIPMENT PAD - ELEVATION
3A120
3A125 3A127 3A129 3A131 3A133 3A135
3A101
3A103
3A123
3A119
C3-6
3A117 3A118
3A153
3A151
C3-3 3A134
3A169
C3-1
3A121
3A1123A122
C
3A108
3A132
3A110
C
C3-5
3A113 3A111 3A109 3A107 3A105 3
A
3A115 3A163 3A165
3A104
3A167
3A149
3A147
C
C3-9
3A156 3A158 3A164 3A166
C
3A171
3A146 3A1423A144 3A1403A145
3A143 C3-12
C
3A141
3A139
3A231
3A182 3A180 3A178 3A176
3A173
3A175
3A184 3A184A 3D187
3A229
3A233
3A181
A
3A177
C
3A227
C3-17A
C A
3A253
3A255
3A257
3A250
3A252
3A204
3A208
C3-13
3A254
3B156
3D198
3A210 3A209
3A211
3A212
3A225
3A223
C3-14
C3-16A
C
3A282
3A2603A258
3A221 3A219 3A217 3A215
3A213
3A279
3A279A
3A277
3A278
3A272
3A270
C3-20 3A275
3A274
3A273
3A276
3A268
C3-18 3A262
3A263
3A271
3A269
C3-21
3A267
3A266
3A264
3A286
D
3D267
3A265
S-4
C3-45
C3-24
3B124
3B125
3B127 3B149
3B117 3B123
3B115
C3-26
B
C
3B116
3B112
3B113
3B110
3B111
3B118
3B122 3B124A
3B128
3B144
3B142 3B140A 3B140
3B130
C
3B129
C3-28
3B131 3B146
C
3B154
3B158
3B105
3B104
3B101
B
3B102
3B106
C
C3-48
3D101 3D103
D
3D104
3B145 3B143 3B141 3B139 3B137 3B135
3B133
3B157
3B189 3B191 3B193 3B195
3B197 3B159
3B187
C3-29
3B186
C
C3-31
3B107
3B108
3B190 3B192 3B194 3B196
3B198 3B165
3B163
3B181
3B179
C3-32
3B177 3B175 3B173
3B167 3B166
3B226
3B184
3B180 3B178 3B176
3B174
3B172
B
3B223
3B228
3B230
C3-34
3B221
C3-33
3B182
3B217 3B219
3B222A
3B220
3B218
3B2163B2143B2123B2103B208
3B222 3B245
3B243
3B241
3B2393B237
3B233
3B235
C3-35
3B238
3B232 C3-38
3B231
3B234 3B236 3B240 3B242 3B244 3B246 C3-36
3B292
3B251
3B253
3B255
3B257
3B252
3B256
C3-41
3B281 3B285
3B289 3B291
3B287
3B280
3B279
3B278
3B277 C3-39
3B276 3B274 3B272 3B270 3B268 3B266 3B264
3B262
C3-42
3B258
3B275
3B273 3B271 3B265
3B286 3B2883B2843B282
3B267
3B261
C3-39
3B260
C3-60
C3-61 3B205
3B204
B
3B201 3B2002
3D111
3D109
3D110
C
C3-65 C3-66
3D105
C3-49
3D180
3D164
3D167
3D165
C
C3-54
3D162
3D159
3D157
3D155
3D153
3D149
3D147
3D148
3D168
3D166
3D160
C
3D113
3D112
3D114
3D116
3D120
3D122
3D128
3D130
3D132
3D126
C A
3D115
3D117
C3-52
3D119
3D125 3D123
3D154 3D127
3D152
3D131
3D133
3D150
3D146
C3-55
C3-63
C3-88
3D141
3D151
3D140 3D144
3D136 3D134
3D231 3D232
3D230 3D229
C3-56
3D225
3D239
3D237
3D235 3D2333D2273D223
3D222
3D221
3D221A
C3-58
3D220
3D218
3D219
3D226
C3-62
3D234
3D236
3D238
3D201
3D203
3D205
D
3D204
3D214 3D212 3D210 3D208 3D206
C3-91
C3-90
C
C3-93
3D484 3D4823D4863D4883D4903D492
3D493
3D494
3D405
3D403
3D401
D
3D404
C3-69 3D309
3D3083D307
3D310A
3D311
3D316
3D317 3D319
3D303
3D301
3D304
C3-70
D
3D305
3D108 3D333
3D335
3D331
3D337 3D339 3D341
C3-73
3D334 3D336 3D338 3D340 3D342
3D332
3D343
3D349 3D174 C3-73A 3D318
3D322
C3-72
3D320
3D389 3D391
3D388
C3-77
3D348
3D3463D344
C
3D324
3D321
3D323
3D326
3D392A
3D393
3D392
3D395
3D397
3D399
3D411
3D390
3D417
3D413
3D415
D
3D394
3D414
3D419
3D432
3D430
3D386
3D398
3D384 3D383
3D382
3D436
3D427
3D434
3D421
3D4163D409
3D410
3D422 3D244
3D240
3D246B
3D246
3D426B
3D426A
3D426
3D246A
3D472
3D328
D
3D352
3D353 3D355 3D357 3D359 3D361 3D363 3D365
3D471
3D470
3D468 3D466 3D464 3D462
3D460
3D458
3D456
3D454
C3-84
C3-86
C3-79
C3-82 C3-80
C3-81
C3-85
3D429
3D356 3D358
3D475
3D473
3D461
3D459
C3-83
3D453
3D4793D477
3D4443D446
3D354
3D374
3D377
3D375
3D373
3D364
3D366
3D368
3D370
3D367
3D360
3D440
3D381
3D369
3D362
3D371
3D437
3D435
3D433
3D431
3D442
3D448
3D452
3D450
P-4
P-7
P-5
P-6
S-3
P-8
P-9
S-1
S-2
P-1 P-2 P-3
S-8
S-7
3A124
3B229
3B227
3B247
3D325
C3-73B
3B132
3B115A
3B164
3B215
C3-1
S-6
ELECTRICAL
ROOM
IT
TELECOM
EXAM EXAM EXAM EXAM EXAM
WAITING
RECEPTION
FACILITIES
SYSTEMS
HAC
CORRIDOR
STAFF
LOUNGE
STAFF
TOILET
PROVIDERS
OFFICE
PROVIDERS
OFFICE
CORRIDOR LINEN
ALCOVE
SCALE
ALCOVE
MAIN
CORRIDOR
PIPE
RISER
CLEAN
UTILITY
SOCIAL
WORKER
OFFICE
C O R R
ID
O R
NURSES
STATION
PATIENT
TOILET
SOILED
UTILITY
C O R R
ID
O R
CORRIDOR
PROCEDURE
EXAM EXAM EXAM EXAM
E L E C
PROCEDURE
RESEARCH
PHARMACIST
RESEARCH
PHARMACIST
STORAGE
CLINICAL
FILESTORAGE
CLEAN
UTILITY
SOILED
UTILITY
C O R R
ID
O R
CORRIDOR
EXAM
CONSULT
EXAM
CONSULT
EXAM
CONSULT
EXAM
CONSULT
C O R R
ID
O R
WAITING
TRIAGE TRIAGE
EXAM
CONSULT
EXAM
CONSULT
STAFF
TOILET
CLINICAL
COORDINATOR
OFFICES
C O R R
ID
O R
CORRIDOR
C O R R
ID
O R
CLINICAL
COORDINATOR
OFFICES
CLINICAL
COORDINATOR
OFFICES
MALE
TOILET
EXAM
CONSULT
EXAM
CONSULT
EXAM
CONSULT
EXAM
CONSULT
RECEPTION
STORAGE
EQUIPMENT
CLINICAL
FILESTORAGE MONITOR
BREAK
ROOM
FEMALE
TOILET
STAFF
TOILET
E L E
CMONITOR
C O R R
ID
O R
CHIEF
NURSEEXECUTIVE
CORRIDOR
C O R R
ID
O R
NURSING
PROFESSIONALSMALL
GROUPOFFICE
NURSING
PROFESSIONALSMALL
OFFICE
NURSING
PROFESSIONALSMALL
OFFICE
NURSING
PROFESSIONALSMALL
OFFICE
NURSING
PROFESSIONALGROUP
LARGEOFFICE
OPERATIONSPLANNER
OFFICE
OPERATIONSCAO
OFFICE
CORRIDOR
NURSING
PROFESSIONALNURSE
RECRUITERSLARGE
OFFICE
NURSING
PROFESSIONALNURSE
RECRUITERSLARGE
OFFICE
RECEPTION/
WAITING
OPERATIONS
COMPLIANCE
OFFICE
DATA
OFFICESMALL
OFFICE(VISN
AUDITOR)
DATA
OFFICESMALL
OFFICEOFFICE (2
MOFHBUDGET
STAFF)
OPERATIONSSMALL
GROUPOFFICE
(CBIVISN and
AUDITOR
CNE
SECRETARYand
WAITING
PROFESSIONAL
ADMINISTRATIVE
OFFICER
CORRIDOR
CORRIDOR
C O R R
ID
O R
KITCHENETTE
HAC
CONFERENCE
ROOM
NURSING
PROFESSIONALFILE
STORAGE
OFFICE OF
THEDIRECTOR
DATA
OFFICEDATA
MANAGER
OPERATIONSPAO
SMALLOFFICE OPERATIONSOFFICE
DATAFILE
STORAGE
HOSPITALDIRECTOR
OFFICE
TOILET
EQUIPMENT
ROOM
HD
SECRETARYand
WAITING
AHD
SECRETARYand
WAITING
COS
SECRETARYand
WAITING
SERVICE
LOBBY
PIPE
RISER
FACILITIES
SYSTEMS
IT
TELECOM
ELECTRICAL
ROOM
OFFICE OF
THEDIRECTOR
CORRIDOR VESTIBULE
RECEPTIONand
WAITING
ASSOCIATE
HOSPITAL
DIRECTOR
CHIEF OF
STAFF
CORRIDOR
PROFESSIONAL
ADMINISTRATIVE
OFFICER
PROFESSIONAL
ADMINISTRATIVE
OFFICER
PROFESSIONAL
ADMINISTRATIVE
OFFICER
OFFICEOF
THEDIRECTOR
E L E C
ELEVATOR
VESTIBULE
TRAINING
OFFICE
ELEVATOR
MAIN
CORRIDOR
CORRIDOR
UROLOGY
EXAM
(BIOPSY)
PLAST.
EXAM
STORAGE
GROUP
OFFICEMULTIPURPOSE
PROCEDURE-
ENT
MULTIPURPOSE
PROCEDURE-
PLASTICS
ENT
EXAM
CORRIDOR
E L E C
C O R R
ID
O R
ENT
EXAM
ENT
EXAM
CLINICAL
MODULE
RECEPTION
WAITING
VESTIBULE
OFFICE
NURSE
MANAGER
PLASTICS
PATIENT
TOILET
PATIENT
TOILET
CLEAN
SUPPLY
UROLOGY
EXAM
PATIENT
TOILET PATIENT
TOILET
UROLOGY
EXAM(MALE
SEXUALTESTING)
SOILED
UTILITY
C O R R
ID
O R
GS
PROCEDURE
OFFICE
PHYSICIAN
GROUP
OFFICE
CLINIC
MANAGER
C O R R
ID
O R
OFFICE
PHYSICIAN
GROUP
STAFF
LOUNGE
ELECTRICAL
ROOM
IT
TELECOM
VESTIBULE
F A C
IL
IT
IE
S
S Y S T E M S
PIPE
RISER
VENDING
C O R R
ID
O R
STAIR
ELECTRICAL
ROOM
IT
TELECOM
V E S T
IB
U L E
FACILITIES
SYSTEM
UROLOGY
EXAM
UROLOGY
EXAM
GENERALSURGERY
EXAM
GENERALSURGERY
EXAM
GENERALSURGERY
EXAM
GENERAL
SURGERY
EXAM
HAC
STAFF
TOILET
ORTHO
EXAM
ORTHO
EXAM PATIENT
TOILET
ORTHO
EXAM
ORTHO
EXAM
PHYSICIAN
OFFICE
CAST
ROOM
CORRIDOR
STORAGE
C O R R
ID
O R
CORRIDOR
PUBLIC
TOILETMENS
PUBLIC
TOILETWOMEN
PREOP
INTAKE
CONSULT
(SW,DIET,PHARM)
THORACIC
EXAM
THORACIC
EXAM
ORTHO
EXAM CLEAN
SUPPLY
LINEN
VASCULAR
EXAM
VASCULAR
EXAM
CORRIDOR
PATIENT
TOILET
NEURO
EXAM
NEURO
EXAM
MEDS
PHYSICIAN
OFFICE
PHYSICIAN
OFFICE
WAITING
PRE-OP
(INTAKE)
MED PRE-OP
EXAM STORAGE
VASC.
LAB
SOILED
UTILITY
E L E C
HBO
EXAM
STAFF
TOILET
STAFF
LOUNGE
CORRIDOR
OFFICE
GROUP
CORRIDOR
CLINICAL
MODULE
RECEPTION
PODIATRY
PROC.
HBO
EXAM
PATIENT
TOILET
HBO
EXAM
PATIENT
TOILETMULTI
PURPOSE
EXAM
PODIATRY
EXAM
PODIATRY
EXAM
PODIATRY
EXAM
PODIATRY
EXAM
HYPERBARIC
CHAMBERSSTORAGE
SOILED
AREA(DISASSEMBLY
ANDCLEAN
UP)
STORAGE
SELF
DIALYSISSUPPORT
PERSONNEL
DIALYSIS
TRAINING
WAITING
RECEPTION
CORRIDOR
ELEC
NURSING
INTAKE CORRIDOR
NURSING
INTAKE
OFFICE,
SOCIALWORKER
OFFICE,
CHIEFNURSE
SECRETARY/
ADMIN
DIALYSIS
CHIEF
DIALYSATE
STORAGE
CLEAN
AREA(PREPARATIONAND
TESTING)
CORRIDOR
1-BED
LKRS
LKRS
OFFICEOF
THEDIRECTOR
HAC
PHYSICIAN
OFFICE
STAFF
TOILET
CORRIDOR
TREATMENT
BAY
TREATMENT
BAY TREATMENT
BAY
TREATMENT
BAY
CLEAN
SUPPLY
TREATMENT
BAY
NOURISHMENT
1-BED
1-BED
CORRIDOR
TREATMENT
BAY
TREATMENT
BAY
TREATMENT
BAY
TREATMENT
BAY
TREATMENT
BAY
TREATMENT
BAY
TREATMENT
BAY
1-BED
ELEVATOR
LOBBY
OFFICEOF
THEDIRECTOR
NURSE
STATION
TREATMENT
BAY
TREATMENT
BAY
TREATMENT
BAY
TREATMENT
BAY
TREATMENT
BAYMEDS
PATIENT
TOILET
PATIENT
TOILET
NURSE
STATION
CORRIDOR
SOILED
UTILITY
CORRIDOR
CORRIDORELECTRICAL
ROOM
IT
TELECOM
IT
T E L E C O M
VESTIBULE PIPE
RISER
WAIT
CORRIDOR
WAIT
WAIT
C O R R
ID
O R
CORRIDOR CORRIDOR
PIPE
RISER
CORRIDOR
HAC
OFFICE
EXAM
EXAM
C O R R
ID
O R
CORRIDOR
EXAM
EXAM
EXAM
EXAM
CARDIAC
REHAB
OFFICE
OFFICE
STAFF
LOUNGE
EXAM
EXAM
EXAM
C O R R
ID
O R
RECEPTION
EXAM
EXAM
EXAM
EXAM
EXAM
ECHO
ECHO
TEE
PACE/
HOLTER
C O R R
ID
O R
PHARMACIST
MEDS
CORRIDOR
NURSES
STATION
CLEAN
UTILITY/EQUIP
STOR. SOILED
UTILITY
PATIENT
TOILET
PATIENT
TOILET
OFFICE
TREADMILL/ECG
STRESS/ECHO
PACEMAKER
CHECK
OFFICE
CORRIDOR
CORRIDOR
CORRIDOR
STAFF
TOILET
ELEC
PATIENT
TOILET
EXAM/
TEST
HAC HAC
PREP/
RECOV
PREP/
RECOV
PREP/
RECOV
NURSE
STATION
CORRIDOR
CLEAN
UTILITY/EQUIP
STOR
OFFICE
OFFICE
OFFICESOILED
UTILITY
CORRIDOR
BLOOD GAS
LAB
STAFF
TOILET
LOCKERS
LOCKERS
STAFF
TOILET
CORRIDOR
SCRUB
CONTROL
READING
CARDIAC
CATH
CORRIDOR
DATA
CONTROL
HEAD
NURSE
ELECTRICAL
ROOM
FACILITIES
SYSTEMS
PIPE
RISER
V E S T
IB
U L E
IT
TELECOM
OFFICE OFFICE OFFICE OFFICE OFFICE
SERVICE
ELEVATOR
LOBBY
CORRIDOR
P A T
IE
N T
T R A N S F E R
E L E V A T O R
L O B B Y
CORRIDOR
OFFICE OFFICEOFFICEOFFICEOFFICE
SCRUB
DISPENSE
OFFICE
FLOOR
MACHINE
ROOM
PIPE
RISER
IT
TELECOM
ELECTRICAL
ROOM
V E S T
IB
U L E
FACILITIES
SYSTEMS
PASSENGERELEVATOR
LOBBY
OFFICE
PUBLIC
TOILETMENS
PUBLIC
TOILETWOMEN
STAFF
LOUNGE
STAFF
TOILET
BRONCH
EGD EGD
IT
TELECOM
ELECTRICAL
ROOM
STAIR
FACILITIES
SYSTEMS
CORRIDOR
V E S T
IB
U L E
PIPE
RISER
RECEPTION PATIENT
TOILET
RECOV
LINEN
ALCOVE
RECOV
RECOV RECOV
CORRIDOR
RECOV RECOV RECOV RECOV RECOV
SOILED
UTILITY
NURSE
STATION
PREP PREP
CORRIDOR MEDS
LINEN
ALCOVE
CORRIDOR
HAC
HAC GURNEY
SCRUB
CORRIDOR
GOWNED
WAITING
PATIENT
TOILET
PATIENT
TOILET
C O R R
ID
O R
SCOPE
CLEAN
EGD
EGD
SCOPE
CLEAN
CONTROL
PLASTER
ANDSPLINT
STOR
CYSTO
O.R
SCRUB
GURNEY
O.R
SUB-STERILE
O.R
SCRUB
GURNEY
E L E C
EQUIP
STOR
GURNEY
SCRUB
SCRUB
O.R
O.R
INST
PREP/STORAGE
SCRUB
SUB
STERILEOPT
A
O.R
O.R
CLEAN
CORE
SUB-STERILE
SUB-STERILE
SOILED
HOLDINGVESTIBULE
BOTTLE
STORAGEANESTHESIA
WORKROOM
LOUNGE/DICTATION
ELEC
STAFF
FACILITIES
MALE
STAFF
FACILITIES
MALE
STAFF
FACILITIES
FEMALE
STAFF
FACILITIES
FEMALE
STAFF
FACILITIES
FEMALE
STAFF
FACILITIES
MALE
STAFF
TOILET
CLEAN
SUPPLY
E L E C
PATIENT
TOILET
PREP/
RECOV
PREP/
RECOV
PREP/
RECOV
PREP/
RECOV
PREP/
RECOV
PREP/
RECOV
PREP/
RECOV
ELEC
RECOV
RECOV RECOV RECOV RECOV
RECOV
RECOV
RECOV
RECOV
C O R R
ID
O R
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
STORAGE
PATIENT
TOILET
PATIENT
TOILET
ANTE
ROOM
ISOLATION
MEDS NURSE
STATION
CORRIDOR
ALCOVE
RECOVRECOV
RECOVRECOV
NURSE
STATION
PREP/
RECOV
PREP/
RECOV
PREP/
RECOV
PREP/
RECOV
ALCOVE
PREP/
RECOV
PREP/
RECOV
PREP/
RECOV
PREP/RECOV
PREP/
RECOV
DICTATION
GURNEY
NURSE
STATION
MEDS/NOURISH
PATIENT
TOILET
VESTIBULE
HAC
GURNEY
X-RAY-STOR
PATIENT
TOILET
SOILED
UTILITY
STAFF
TOILET
CLEAN
SUPPLY/STORAGE
ELEVATOR
ELEVATOR
ELEVATOR
ELEVATOR
ELEVATOR
ELEVATOR
ELEVATOR
ELEVATOR
ELEVATOR
ELEVATOR ELEVATOR ELEVATOR
ELEVATOR
ELEVATOR
SCALE
ALCOVE
ALCOVE
ALCOVE
ALCOVE
ALCOVE
ALCOVE
ALCOVE
ALCOVE
ALCOVE
STAIR
STAIR
STAIR
STAIR
STAIR
STAIR
STAIR
STAIR
MAIN
CORRIDOR
DUMBWAITER
55.04.00.05.0
55.04.0
0.05.0
55.04.0
0.05.0
55.04.00.05.0
SUITE DESCRIPTIONS
LIFE SAFETY LEGEND
1. THE LIFE SAFETY PLANS ARE "DIAGRAMMATIC ONLY". THEIR PURPOSE IS SOLELY
TO REPRESENT THE LIFE SAFETY COMPONENTS FOR THE PROJECT. THE
GENERAL CONTRACTOR SHALL USE THE CONSTRUCTION DOCUMENTS (NOT THE
LIFE SAFETY PLANS) FOR THE IMPLEMENTATION OF THE OF THE REQUIRED LIFE
SAFETY COMPONENTS INTO THE PROJECT.
1. UL LISTED 2 HOUR WINDOW SPRINKLER PROTECTION.
2. FLOOR OPENINGS PROTECTED WITH SMOKE DETECTOR CONTROLLED FIRE
SHUTTERS IN ACCORDANCE WITH SECTION 8.6.8.6(3) OF NFPA 101-2003 EDITION.
3. SMOKE SHUTTER.
4. UL LISTED FIRE RATED ACCORDION DOOR.
5. 90 MINUTE FIRE DOOR AND FRAME LABELS UNDER PIANO HINGE.
APPLICABLE CODES
2021 NFPA 101 - NATIONAL FIRE PROTECTION ASSOCIATION LIFE SAFETY CODE
NATIONAL FIRE CODES, WITH THE EXCEPTION OF NFPA 5000 AND NFPA 900
2021 IBC - INTERNATIONAL BUILDING CODE
OSHA - OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION
7/1/2023 VA SEISMIC DESIGN REQUIREMENTS, H-18-8.
2023 NEC - NATIONAL ELECTRIC CODE
2021 IPC - INTERNATIONAL PLUMBING CODE
11/1/2022 ABAAS ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARDS
INCLUDING VA SUPPLEMENT, BARRIER FREE DESIGN GUIDE (PG-18-13)
VA DIRECTIVES, DESIGN MANUALS, MASTER SPECIFICATIONS, VA
NATIONAL CAD STANDARD APPLICATION GUIDE, AND OTHER GUIDANCE ON
THE TECHNICAL INFORMATION LIBRARY (TIL) (WWW.CFM.VA.GOV/TIL/)
OCCUPANCY GROUP
IBC INSTITUTIONAL GROUP 1-2 (HOSPITALS) SECTION 308.3.
NFPA 101 OCCUPANCY GROUP HEALTHCARE USE 7.3.1.2
OCCUPANT LOAD FACTOR
IBC TABLE 1004.5 MAX. FLOOR AREA ALLOWANCES PER OCCUPANT 240
NFPA 101 7.3.1.2 OCCUPANCY GROUP HEALTHCARE LOAD FACTOR 240
BUILDING CONSTRUCTION CLASSIFICATION
NFPA 101 CONSTRUCTION TYPE 1 (332) TABLE 19.1.6.1 EXISTING HEALTHCARE
OCCUPANCY
IBC TABLE 601 (1-A)
FIRE RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS PER IBC TABLE
I-A
3 HR. PRIMARY STRUCTURAL FRAME
3 HR. BEARING WALLS-EXTERIOR
3 HR. BEARING WALLS-INTERIOR
NONBEARING WALLS & PARTITIONS TABLE 602
0 HR. NONBEARING WALLS & PARTITION-INTERIOR
2 HR. FLOOR CONSTRUCTION & SECONDARY MEMBERS SECTION 202 (N/A)
1 1/2 HR. ROOF CONSTRUCTION AND ASSOCIATED SECONDARY MEMBERS
SECTION 202 (N/A)
BUILDING IS PROTECTED THROUGHOUT BY AN AUTOMATIC SPRINKLER SYSTEM
NFPA 101 TABLE A7.6
COMMON PATH OF TRAVEL LIMITS SPRINKLERED EXISTING HEALTHCARE NR
DEAD-END LIMIT SPRINKLERED EXISTING HEALTHCARE 30 FT
TRAVEL DISTANCE LIMITS SPRINKLERED EXISTING HEALTHCARE 200FT
INTERIOR FINISHES PER IBC TABLE 803.13
CLASS B INTERIOR EXIT STAIRWAYS & RAMPS
CLASS B CORRIDORS & ENCLOSURE FOR EXIT ACCESS STAIRWAYS & RAMPS
CLASS B ROOMS & ENCLOSED SPACES
F
F
F
F
F F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
SD. 01
SD. 02
SD. 03
SD. 04
SD. 07
SD. 05
SD. 06
SD. 11
SD. 10
SD. 09
SD. 08
SD. 13
SD. 12
SD. 14
ZONE 3-1
ZONE 3-2
ZONE 3-5ZONE 3-3
ZONE 3-7
ZONE 3-8
ZONE 3-7ZONE 3-5
ZONE 3-11
GI202
S1
S2
P1
P2
SUITE NUMBER SUITE NAME SUITE SIZE TYPE OF SUITE
SD. 01 GI RECOVERY 4,435 SQFT.
NON SLEEPING
PATIENT CARE
SD. 02 O.R. 7,200 SQFT.
NON SLEEPING
PATIENT CARE
SD. 03
PACU PATIENT
CARE
3,200 SQFT.
NON SLEEPING
PATIENT CARE
SD. 04
SAME DAY
PATIENT CARE
4,700 SQFT.
NON SLEEPING
PATIENT CARE
SD. 05 CATH LAB 3,660 SQFT.
NON SLEEPING
PATIENT CARE
SD. 06 CARDIAC REHAB 8,650 SQFT.
NON SLEEPING
PATIENT CARE
SD. 07 DIALYSIS 7,600 SQFT.
NON SLEEPING
PATIENT CARE
SD. 08 PEDIATRY 2,200 SQFT.
NON SLEEPING
PATIENT CARE
SD. 09 VASCULAR 2,000 SQFT.
NON SLEEPING
PATIENT CARE
SD. 10 ORTHO 2,400 SQFT.
NON SLEEPING
PATIENT CARE
SD. 11 UROLOGY 5,000 SQFT.
NON SLEEPING
PATIENT CARE
SD. 12
RENAL /
NEPHROLOGY
5,400 SQFT.
NON SLEEPING
PATIENT CARE
SD. 13
COMPENSATION
& PENSION
5,000 SQFT.
NON
PATIENT CARE
SD. 14
WOMENS
HEALTH
10,000 SQFT.
NON SLEEPING
PATIENT CARE
X'-X"
EMERGENCY LIGHT
FIRE EXTINGUISHER CABINET
EXIT
FIRE ALARM - MANUAL PULL STATION
EXIT PASSAGEWAY
LINEN CHUTE
TRASH CHUTE
HORIZONTAL EXIT PASSAGEWAY
SPRINKLER / FIRE ALARM ZONE
EGRESS DIRECTIONAL ARROW
ILLUMINATED EXIT SIGN / DIRECTION
TRAVEL DISTANCE START CIRCLE
MAXIMUM TRAVEL DISTANCE
2 HOUR FIRE/SMOKE ZONE BARRIER
2 HOUR FIRE BARRIER
SMOKE ZONE BARRIER
1 HOUR FIRE/SMOKE BARRIER
1 HOUR FIRE BARRIER
NON-RATED SMOKE ZONE
PARTITION
HEALTH CARE OCCUPANCY
CORRIDORS
SPRINKLER AND FIRE ALARM
ZONE BOUNDARY
PHASING BOUNDARY
CONTRACTOR ACCESS
1 HOUR FIRE BARRIER
HAZARDOUS ROOM ENCLOSURE
SMOKE RESISTIVE
HAZARDOUS ROOM ENCLOSURE
EXIT STAIRWELL / PASSAGEWAY
AREA OPEN TO CORRIDOR WITH
SMOKE DETECTION
SUITE DESIGNATION
NO SCOPE OF WORK
F
EP
LC
TC
HE
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
U.S. Department of Veterans Affairs
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
Spinklered
NORTH
FULLY SPRINKLERED
B
IM
/V
IS
N
L a s V e g a s R e p la c e
F lo o r
S p e c C lin ic s /L a s V e g a s R e p la c e F lo o r
S p e c C lin ic s
V
.r v t
/1
/2
:5
:0
A
M
RCO DRC
593-19-310
GI201
593 - NORTH LAS VEGAS, NV
MARCH 19, 2024
01-
THIRD LEVEL OVERALL LIFE SAFETY PLAN 100% CONSTRUCTION
DOCUMENT SUBMISSION
REPLACE FLOORING IN OR, PACU,
AND SPECIAL PROCEDURES
1" = 20'-0"
THIRD LEVEL OVERALL LIFE SAFETY PLAN
5 5
3D101 3D103
D
3D104
3D111
3D109
3D110
C
C3-65 C3-66
3D105
C3-49
3D180
3D164
3D167
3D165
C
C3-54
3D162
3D159
3D157
3D155
3D153
3D149
3D147
3D148
3D168
3D166
3D160
C
3D113
3D112
3D114
3D116
3D120
3D122
3D128
3D130
3D132
3D126
C A
3D115
3D117
C3-52
3D119
3D125
3D123
3D154 3D127
3D152
3D131
3D133
3D150
3D146
C3-55
C3-63
C3-88
3D141
3D151
3D140 3D144
3D136 3D134
3D231 3D232
3D230 3D229
C3-56
3D225
3D239
3D237
3D235 3D2333D2273D223
3D222
3D221
3D221A
C3-58
3D220
3D218
3D219
3D226
C3-62
3D234
3D236
3D238
3D201
3D203
D
3D204
3D214 3D212 3D210 3D208 3D206
C3-91
C3-90
C
C3-93
3D484 3D4823D4863D4883D4903D492
3D493
3D494
3D405
3D403
3D401
D
3D404
C3-69 3D309
3D3083D307
3D310A
3D311
3D316
3D317 3D319
3D303
3D301
3D304
C3-70
D
3D305
3D108 3D333
3D335
3D331
3D337 3D339 3D341
C3-73
3D334 3D336 3D338 3D340 3D342
3D332
3D343
3D349 3D174 C3-73A 3D318
3D322
C3-72
3D320
3D389 3D391
3D388
C3-77
3D348
3D3463D344
C
3D324
3D321
3D323
3D326
3D392A
3D393
3D392
3D395
3D397
3D399
3D411
3D390
3D417
3D413
3D415
D
3D394
3D414
3D419
3D432
3D430
3D386
3D398
3D384 3D383
3D382
3D436
3D427
3D434
3D421
3D4163D409
3D410
3D422 3D244
3D240
3D246B
3D246
3D426B
3D426A
3D426
3D246A
3D472
3D328
D
3D352
3D353 3D355 3D357 3D359 3D361 3D363 3D365
3D471
3D470
3D468 3D466 3D464 3D462
3D460
3D458
3D456
3D454
C3-84
C3-86
C3-79
C3-82 C3-80
C3-81
C3-85
3D429
3D356 3D358
3D475
3D473
3D461
3D459
C3-83
3D453
3D4793D477
3D4443D446
3D354
3D374
3D372
3D377
3D375
3D373
3D364
3D366
3D368
3D370
3D367
3D360
3D440
3D381
3D369
3D362
3D371
3D437
3D435
3D433
3D431
3D442
3D448
3D452
3D450
P-4
P-7
P-5
P-6
P-8
P-9
S-1
S-2
S-8
S-7
3D325
C3-73B
S-6
STAIR
ELECTRICAL
ROOM
IT
TELECOM
V E S T
IB
U L E
FACILITIES
SYSTEM
WAIT
WAIT
WAIT
C O R R
ID
O R
CORRIDOR CORRIDOR
PIPE
RISER
CORRIDOR
HAC
OFFICE
EXAM
EXAM
C O R R
ID
O R
CORRIDOR
EXAM
EXAM
EXAM
EXAM
CARDIAC
REHAB
OFFICE
OFFICE
STAFF
LOUNGE
EXAM
EXAM
EXAM
C O R R
ID
O R
RECEPTION
EXAM
EXAM
EXAM
EXAM
EXAM
ECHO
ECHO
TEE
PACE/
HOLTER
C O R R
ID
O R
PHARMACIST
MEDS
CORRIDOR
NURSES
STATION
CLEAN
UTILITY/EQUIP
STOR. SOILED
UTILITY
PATIENT
TOILET
PATIENT
TOILET
OFFICE
TREADMILL/ECG
STRESS/ECHO
PACEMAKER
CHECK
OFFICE
CORRIDOR
CORRIDOR
CORRIDOR
STAFF
TOILET
ELEC
PATIENT
TOILET
EXAM/
TEST
HAC HAC
PREP/
RECOV
PREP/
RECOV
PREP/
RECOV
NURSE
STATION
CORRIDOR
CLEAN
UTILITY/EQUIP
STOR
OFFICE
OFFICE
OFFICESOILED
UTILITY
CORRIDOR
BLOOD GAS
LAB
STAFF
TOILET
LOCKERS
LOCKERS
STAFF
TOILET
CORRIDOR
SCRUB
CONTROL
READING
CARDIAC
CATH
CORRIDOR
DATA
CONTROL
HEAD
NURSE
ELECTRICAL
ROOM
FACILITIES
SYSTEMS
PIPE
RISER
V E S T
IB
U L E
IT
TELECOM
OFFICE OFFICE OFFICE OFFICE OFFICE
SERVICE
ELEVATOR
LOBBY
CORRIDOR
P A T
IE
N T
T R A N S F E R
E L E V A T O R
L O B B Y
CORRIDOR
OFFICE OFFICEOFFICEOFFICEOFFICE
SCRUB
DISPENSE
OFFICE
FLOOR
MACHINE
ROOM
PIPE
RISER
IT
TELECOM
ELECTRICAL
ROOM
V E S T
IB
U L E
FACILITIES
SYSTEMS
PASSENGERELEVATOR
LOBBY
OFFICE
PUBLIC
TOILETMENS
PUBLIC
TOILETWOMEN
STAFF
LOUNGE
STAFF
TOILET
BRONCH
EGD EGD
IT
TELECOM
ELECTRICAL
ROOM
STAIR
FACILITIES
SYSTEMS
CORRIDOR
V E S T
IB
U L E
PIPE
RISER
RECEPTION PATIENT
TOILET
RECOV
LINEN
ALCOVE
RECOV
RECOV RECOV
CORRIDOR
RECOV RECOV RECOV RECOV RECOV
SOILED
UTILITY
NURSE
STATION
PREP PREP
CORRIDOR MEDS
LINEN
ALCOVE
CORRIDOR
HAC
HAC GURNEY
SCRUB
CORRIDOR
GOWNED
WAITING
PATIENT
TOILET
PATIENT
TOILET
C O R R
ID
O R
SCOPE
CLEAN
EGD
EGD
SCOPE
CLEAN
CONTROL
PLASTER
ANDSPLINT
STOR
CYSTO
O.R
SCRUB
GURNEY
O.R
SUB-STERILE
O.R
SCRUB
GURNEY
E L E C
EQUIP
STOR
GURNEY
SCRUB
SCRUB
O.R
O.R
INST
PREP/STORAGE
SCRUB
SUB
STERILEOPT
A
O.R
O.R
CLEAN
CORE
SUB-STERILE
SUB-STERILE
SOILED
HOLDINGVESTIBULE
BOTTLE
STORAGE
ANESTHESIA
WORKROOM
LOUNGE/DICTATION
ELEC
STAFF
FACILITIES
MALE
STAFF
FACILITIES
MALE
STAFF
FACILITIES
FEMALE
STAFF
FACILITIES
FEMALE
STAFF
FACILITIES
FEMALE
STAFF
FACILITIES
MALE
STAFF
TOILET
CLEAN
SUPPLY
E L E C
PATIENT
TOILET
PREP/
RECOV
PREP/
RECOV
PREP/
RECOV
PREP/
RECOV
PREP/
RECOV
PREP/
RECOV
PREP/
RECOV
ELEC
RECOV
RECOV RECOV RECOV RECOV
RECOV
RECOV
RECOV
RECOV
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
STORAGE
PATIENT
TOILET
PATIENT
TOILET
ANTE
ROOM
ISOLATION
MEDS NURSE
STATION
CORRIDOR
ALCOVE
RECOVRECOV
RECOVRECOV
NURSE
STATION
PREP/
RECOV
PREP/
RECOV
PREP/
RECOV
PREP/
RECOV
PREP/
RECOV
ALCOVE
PREP/
RECOV
PREP/
RECOV
PREP/
RECOV
PREP/RECOV
PREP/
RECOV
DICTATION
GURNEY
NURSE
STATION
MEDS/NOURISH
PATIENT
TOILET
VESTIBULE
HAC
GURNEY
X-RAY-STOR
PATIENT
TOILET
SOILED
UTILITY
STAFF
TOILET
CLEAN
SUPPLY/STORAGE
ELEVATOR
ELEVATOR
ELEVATOR
ELEVATOR
ELEVATOR
ELEVATOR
ELEVATOR
ELEVATOR
ELEVATOR
ELEVATOR
ALCOVE
ALCOVE
STAIR
STAIR
STAIR
STAIR
DUMBWAITER
55.04.00.05.0
55.04.00.05.0 55.04.00.05.0
LIFE SAFETY NOTES
LIFE SAFETY LEGEND
KEY PLAN
PHASING EGRESS LEGEND
S1
S2
P1
P2
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
ZONE 3-7
ZONE 3-8
ZONE 3-7ZONE 3-5
PHASE 3
PHASE 1
PHASE 2
DEDUCTIVE ALTERNATE 3
DEDUCTIVE ALTERNATE 1 DEDUCTIVE ALTERNATE 2
1. THE LIFE SAFETY PLANS ARE "DIAGRAMMATIC ONLY". THEIR PURPOSE IS SOLELY
TO REPRESENT THE LIFE SAFETY COMPONENTS FOR THE PROJECT. THE
GENERAL CONTRACTOR SHALL USE THE CONSTRUCTION DOCUMENTS (NOT THE
LIFE SAFETY PLANS) FOR THE IMPLEMENTATION OF THE OF THE REQUIRED LIFE
S…